2
MP HYDRAULIC LIFT EQUIPMENT Sava3 www.mplifts.com TECHNICAL SPECIFICATIONS • Complies with standard EN81.2.A3 requirements. • EC certificate of electromagnetic compability. • Pressure switch acting as a load weighing device. • Control systems for oil temperature. • Motor protection through PTC thermistors. • Check and adjustment of each group simulating the installation. • High-quality drain pump and low sound level (58-66 dB). • Motor voltages: - 230/400 - 400/692 - 415/720 a 50 Hz. - 220/380 a 60 Hz. • Other available voltages (single-phase). • Emergency valve voltage 12 Vdc (except 95/16 Directive). • Valve voltages 220 Vdc, 110 Vdc, 60 Vdc, 48 Vdc. • Automatic Rescue if 95/16 Directive must be complied. • Attenuator (silencer) of the pulsations caused by the pump. • Tank reduced dimensions and transport facility. • Lift speeds up to 1 m/s. • Inductive Sensors for valve monitoring valve if 95/16 Directive must be complied. • Star-Delta Starting in installations that must comply 95/16 Directive.

MP HYDRAULIC LIFT EQUIPMENT - mpyenerovunc.com hidrolik kit 1.pdf · MP HYDRAULIC LIFT EQUIPMENT Sava3 TECHNICAL SPECIFICATIONS • Complies with standard EN81.2.A3 requirements

  • Upload
    vanmien

  • View
    289

  • Download
    7

Embed Size (px)

Citation preview

Page 1: MP HYDRAULIC LIFT EQUIPMENT - mpyenerovunc.com hidrolik kit 1.pdf · MP HYDRAULIC LIFT EQUIPMENT Sava3 TECHNICAL SPECIFICATIONS • Complies with standard EN81.2.A3 requirements

MP HYDRAULICLIFT EQUIPMENTSava3

www.mplifts.com

TECHNICAL SPECIFICATIONS

• ComplieswithstandardEN81.2.A3requirements. • ECcertificateofelectromagneticcompability. • Pressureswitchactingasaloadweighingdevice. • Controlsystemsforoiltemperature. • MotorprotectionthroughPTCthermistors. • Checkandadjustmentofeachgroupsimulatingtheinstallation.• High-qualitydrainpumpandlowsoundlevel(58-66dB). • Motorvoltages:

- 230/400-400/692-415/720a50Hz.- 220/380a60Hz.

• Otheravailablevoltages(single-phase).• Emergencyvalvevoltage12Vdc(except95/16Directive).• Valvevoltages220Vdc,110Vdc,60Vdc,48Vdc.• AutomaticRescueif95/16Directivemustbecomplied.• Attenuator(silencer)ofthepulsationscausedbythepump.• Tankreduceddimensionsandtransportfacility.• Liftspeedsupto1m/s. • Inductive Sensors for valve monitoring valve if 95/16 Directive must becomplied.

• Star-DeltaStartingininstallationsthatmustcomply95/16Directive.

Page 2: MP HYDRAULIC LIFT EQUIPMENT - mpyenerovunc.com hidrolik kit 1.pdf · MP HYDRAULIC LIFT EQUIPMENT Sava3 TECHNICAL SPECIFICATIONS • Complies with standard EN81.2.A3 requirements

MP HYDRAULICLIFT EQUIPMENTSava3

www.mplifts.com

FTCHDSAVA3ENV00

TankType

Flow(l/m)

Dimensions Pipe(steel-flex)

Max.Capacity (Iitres)

Useful Oil(Iitres)

Weight(Kg)A B C E H M

T1 25/150 810 775 470 630 1010 M45x2 Diameter-351.1/4” 170 140 110

T2 25/210 870 820 560 750 1110M45x2 Diameter-351.1/4”

240 180 103M52x2 Diameter-421.1/2”

T3 250/430 1020 1020 605 960 1300 M52x2 Diameter-421.1/2” 410 310 180

B

C

E

A H

MP Valves block

Silencer

Motor-pump unit

Inductive Sensors95/16 Directive

Anti-vibrationrubber feet

Hand pump

Filter shut-off valve