50
> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 1 Moving Towards Condition Based Maintenance of Valves and Actuators IEEE Subcommittee on Qualification IEEE/NPEC/SC 2 Meeting 06-1 San Antonio, TX April 18 th , 2006 Peter Brückner AREVA NP GmbH Valve Diagnostic Systems SD-G Seligenstädter Str. 100, D-63791 Karlstein, Germany Tel.: +49 6188 780 9258 [email protected]

Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

Embed Size (px)

Citation preview

Page 1: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 1

Moving Towards Condition Based Maintenance

of Valves and ActuatorsIEEE Subcommittee on Qualification

IEEE/NPEC/SC 2 Meeting 06-1 San Antonio, TX

April 18th, 2006

Peter Brückner

AREVA NP GmbHValve Diagnostic Systems SD-G

Seligenstädter Str. 100, D-63791 Karlstein, Germany

Tel.: +49 6188 780 [email protected]

Page 2: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 2

Who is AREVA NP ?

§ “AREVA NP” new name effective since April 1st, 2006

§ 2001 “Framatome-ANP”, a joint venture of French/US Framatome, andGerman Siemens KWU

§ Building, fuel supply and service for NPPs

§ US branch headquarters in Lynchburg, VAFrench locations in Paris, Lyon, Chalon, and othersGerman locations in Erlangen, Offenbach, Karlstein

§ Now building the new EPR in Finland (Olkiluoto-3)

Page 3: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 3

Part 1:

Introduction

Page 4: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 4

Methods of Maintenance

§Maintenance on occurrence of faults⇒ Not acceptable for nuclear power plants

§ Maintenance in regular time intervals (preventive m.)⇒ Standard for safety related components⇒ Much unnecessary work if components are OK⇒ Faults detected too late

§ Condition Based Maintenance

Page 5: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 5

Condition Based Maintenance

Why ?

§ Prevent unnecessary work

§ Prevent faults caused by the maintenance work

§ Save time and costs

§ Improve plant safety and availability

Why not yet ?

§ Rules and regulations of governments or authorities oftenrequire fixed intervals

§ Lack of information about the condition

Page 6: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 6

Condition Based Maintenance

The way to condition based maintenance of Motor Operated Valves (MOVs)

§ Use new diagnostic methods and tools to gain moreinformation about the “health condition” of MOVs

§ Start with non safety-related, operational important MOVs

§ In Germany, possibilities for the prolongation of maintenance intervals are under negotiation between plant owners and the authorities

Page 7: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 7

Ability for FunctionAnalytical Concept

Readiness for FunctionMonitoring, Trends during Lifetime

BaselineMeasurement

Periodical Tests,

Trending

Full flow testing in test-rig or plant,covering operation and

accident conditions

Measures during Lifetime

Condition Oriented Maintenance

The Valve Performance Concept

Calculation

Actuator andValve Components

Design Evaluation

Function-relevant features, mechanics

Page 8: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 8

How to Know about the Condition of MOVs

§Measurements in-situ at the MOV (with stem thrust)⇒ Best amount of information⇒ Many tools exist on the market⇒ High efforts and costs⇒ Often impossible during operation of plant

§ Remote measurements from Motor Control Center (MCC)⇒ Less information requires additional methods⇒ Easy to do and relative cheap⇒ Possible even during operation of plant

Page 9: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 9

Part 2:

Theoretical Concepts andBackgrounds

SIPLUG® = Measurement equipment

ADAM® = Analysis software

Page 10: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 10

The Concept of Remote Diagnosis from MCC

The motor is used as a sensor for the mechanical behaviour of the MOV

Periodic tests by electrical measurements from the switch gear (MCC) using SIPLUG® technologyð Time saving, possible even during power operationð Mechanical parameters are calculated by ADAM®

Measurements at the valve only - when anomalies are detected or- for calibration(Baseline Measurements)

Page 11: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 11

The Motor as a Sensor for Actuator and Valve (1)

> Energy Flow

Gear Worm Gear

Stem Nut Thread

M

ω

M

ω

M

ω

F

v

Pmech1 = M*ω Pmech2 = M * ω Pmech3 = M * ω Pstem = F * v

Motor

U

J

Pel = f(U,I)

From main power supply with constant frequency

Page 12: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 12

Location of measurement

Cable Motor stator

P=3 U(t)*I(t)

Ploss1=3*I2*RLActive power losses, power lines

P - Ploss1

Ploss2=3*I2*RwActive power losses, winding

Plm+LActive power losses for magnetization

P = M*ω

P - Ploss1 -Plm+L- Ploss2

Power flow from stator to rotor is proportional to Torque

M = Pair gap / ω0

Prot =Θ/2*ω2

Storage

Motor rotor

Ploss3 = ƒ (Slip)

Active power losses in rotor

The Motor as a Sensor for Actuator and Valve (2)

> Determinationof Air-Gap Power

Page 13: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 13

Why Power instead of Current Envelope ? (1)

§ Current envelope is no indication of the mechanical load, because of change of power factor !

§

Power

Current envelope (RMS)

P [kW]

I [A]

Page 14: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 14

0

1

2

3

4

0 1 2 3

“Heylands-Circle”

With load Increasing slip

Stall point

No-Load

Operating range

Active current

Reactive current

Apparent current

Why Power instead of Current Envelope ? (2)

Page 15: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 15

Part 3:

PracticalImplementationof Measurements

Page 16: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 16

Requirements for Diagnosis Equipment in MCC (1)

§ Must be qualified for use in safety related environment⇒ Electrical safety⇒ Seismic tests⇒ Electromagnetic compatibility [EMC]⇒ Only qualified sub-components (e.g. fuses) at the

interface to I&C

§ High Accuracy⇒ <= 1% for electrical signals

Page 17: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 17

Requirements for Diagnosis Equipment in MCC (2)

§Must not have any influence on the I&C and MCC⇒ Non-reactive design, inherently safe⇒ Solution: Voltage and current pick-ups via

measurement transformers

Page 18: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 18

Requirements for Diagnosis Equipment in MCC (3)

§ Easy to use⇒ Short preparation time before measurement⇒ No risks with work at open high voltage ⇒ As few as possible manual settings

Current signals(output of

transformers)

Motor voltagesignals and

opening/closingcommand

signals

Socket codefor automaticrecognition of

MOV

Page 19: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 19

L1 L2 L3 Command Opening/Closing

To MOV

Fuses

Current Transformers*

Fuses

Diagnosis

Socket

12

12-Bitindividual

SocketIdentification

Code

SIPLUG

12

A/D Conversion,

Data Storage,

ControllerRS-232

3-Phase VoltageTransformer

Amplifiers

Optical Isolators

* 2 pieces for ARON / 3 for standard

Functional Diagram of Mobile SIPLUG®

Page 20: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 20

History of Diagnosis Equipment by AREVA NP Karlstein (1)

> 1975 Qualification of actuators (LOCA tests)at the Karlstein laboratories (KWU)ð The motor is used as a remote sensor to estimate the actuator’s

mechanical behavior

Development of sensor technologyð Torque and stem thrust with strain gaugesð Sensors/transformers for active power measurement

> 1990 “MCC-DAW” Power Measurement during Operation ð Active power measurement from the Motor Control Center (MCC)ð Permanently installed current transformers and

diagnosis sockets at the cabinets allow measurementsat any time, even during power operation of plant

Page 21: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 21

History of Diagnosis Equipment by AREVA NP Karlstein (2)

-1,000 0 1,000 2,000 3,000 4,000 5,000 6,000 7,0000

0,025

0,050

0,075

0,100

0,125

0,150

0,175

0,200

> 1997 “SIPLUG®” Miniature Measurement Deviceð Compatible to the MCC-DAW diagnosis sockets, but much

smaller and easier to handle. ð Low-cost compared to other equipment.

> 1998 “ADAM®” Evaluation Software for Valve Diagnosisð Database for all kind of data (master data, measurements, evaluation results) ð Trending and statistical comparisons of resultsð Assessment based on calculated limitsð Automatic evaluation ð Easy to use graphical display

Page 22: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 22

Qualification of SIPLUG components

> Seismic tests according to German KTA and “Konvoi” rules of:

– Current transformers– Mounting material– SIPLUG sockets– Complete cubicles with– SIPLUG Online-3

> EMC tests according to EN 61000-6-4:2001 and EN 61000-6-2:2001

> ADAM software qualificationfor NPP Neckarwestheim

Page 23: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 23

Example for Installation of Diagnosis Socket

Fuses CurrentTransformers

Socket

Page 24: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 24

The Smart Solution with SIPLUG®

• Low preparation effort -- Just plug the SIPLUG-- Clearance from control

room NOT required

• Only 1 person-- No special knowledge

• No risks for operator-- No open voltage

• Measurement withoutoperator on site

-- e.g. during the night

• Automatic detection ofvalve and power range

-- by coded sockets

Page 25: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 25

SIPLUG® Technical Data (1)

• Microprocessor controlled miniature data acquisition module

• Battery powered autonomous operationUp to 400 sec internal storage

• Easy handling

• Low cost

• Measurement at any time from the MCCPermanently installed current transformers, it is not necessary to open circuit. Automatic trigger when actuator starts.

• Full ohmic isolation for plant safetyInductive current and voltage transformers,additional fuses for selective protection

• High accuracy< 1%, each SIPLUG is calibrated. (typ. 0.2 - 0.6%)

Page 26: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 26

• Internal sample rate 4kHz, output rate 250Hz3 channels voltage, 2 or 3 channels current

• 1 MByte RAM (about 400s storage time)

• Output channels:active power1 voltage L1-L3 (RMS)3 currents I1, I2, I3 (RMS)command voltages opening/closing

• RS-232 interfacefor data transfer to PC, 57600 baud

• Standard 9V batteryfor approx. 6 months usage

SIPLUG® Technical Data (2)

Page 27: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 27

The 3 Versions of SIPLUG® for Valve Diagnosis

Diagnosis Socket and Mobile, Pluggable SIPLUG®

Online SIPLUG® for Cable Outlet („SIPLUG Online-2“)

Online SIPLUG® for Integration into Plug-in Units(„SIPLUG Online-3“)

Page 28: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 28

S1

S2

Control voltages from main circuit breakers, commands for opening or closing

S3

L3

L2

L1

L3

L2

ca. 100 mm

ca.

80

mm

 

CAN

RS232

24 V

Mounting: on C-profiles

Mot

or

L1

Fuses1,5 kA interuptingcurrent

3-phasevoltage transformerfor ohmic isolation

Currenttransformers

(5/10/20/50/100A)

A/D Conversion,

Data Storage,

Controller

i1 i3

U1

U2

U3

2

2

i2

Functional Diagram of SIPLUG® Online-2 (Cable Outlet Version)

The module includes all elements required for connecting to the power circuit and to the control circuit of the actuator, sensors, signal processing and network interfaces.

Page 29: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 29

Overview of SIPLUG® Online-3 Installation (Plug-in Unit Version)

SIPLUG

Exi

stin

g O

ffic

e L

AN

(Eth

ern

et)

MOV LAN (Ethernet)

CANEthernetBridge

SIPLUG

SIPLUG

SIPLUG

CANEthernetBridge

SIPLUG

SIPLUG

SIPLUG

SIPLUG

MOV Server

Workstation 1

Workstation 2

BrakeMDP

DAW

Controller PCfor Bench Test

RS232

Plug-in Units

Plug-in Units

...

...

SIPLUGAcquisition

Module

CAN-Bus

MOV

CableOutlet

Page 30: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 30

Power circuit interface(current transformers, voltage

transformer, fuses) [Shielding removed]

SIPLUG Online-3 control electronic

Connector for external display and control button box

Integration of SIPLUG® Online-3 into Plug-in Control Unit

• Complete Integration in the Plug-in UnitSensors as well as signal processing are firmly designed into theplug-in unit.

Example: German „8PU“ plug-in unit (very small !)Can be adapted to other designs (e.g. EPR SIVACON)

Page 31: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 31

SIPLUG® SOV and ADAM® SOV for Solenoid Valves

SIPLUG® SOVData acquisition hardware

ADAM® SOV SoftwareDiagrams of current and voltage

Page 32: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 32

Part 4:

Analysis andAssessment of Measurements

Page 33: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 33

Trending and

Statistics

+

Active Power P

Globe Valve Time tOpen OpenClosed ClosedGlobe Valve

1 1

2

2

3

4 4

5

Power Signature for Globe Valves

Analytical Evaluation

by Calculation of Nominal and Limit

Values

Baseline Measurement

DiagnosticActive Power Measurement

+ + +

Permissible tolerances forcertain parameters, e.g.

Zero load power

Running power

Torque switch off

Running time

Max. unseating power

1

2

3

4

5

Condition-Based Maintenance=

Page 34: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 34

A)

What can be Derived from Electrical Measurement ?

§Active Power minus losses on cables and stator gives the Air-Gap Power.

§Air-Gap Power is proportional to motor torque.

§By use of bench test characteristic curves, actuator output torque can be quantified later.

§ If the rigidity of the valve is known, the final stem thrustcan be calculated out of the stressing time.

§Trending and statistical comparison of similar MOVs.

Page 35: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 35

Power Signature of Wedged Gate Valves Opening with Hammerblow & Unwedging

Page 36: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 36

Power Signature of Wedged Gate Valves Closing with Wedging

Page 37: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 37

Qualitative Assessment of Power Signature

Newest measurement (blue) has longer no-load time than similar valves

Reason: Incorrect stackingof distance rings

Page 38: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 38

B)

What can be Derived from Electrical Measurement ?

§Active Power minus losses on cables and stator gives the Air-Gap Power.

§Air-Gap Power is proportional to motor torque.

§By use of bench test characteristic curves, actuator output torque can be quantified later.

§ If the rigidity of the valve is known, the final stem thrustcan be calculated out of the stressing time.

§Trending and statistical comparison of similar MOVs.

Page 39: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 39

Baseline Measurement - Bench Test

– Torque / active power

– Torque / worm gear displacementangle of rotation

§ Periodic tests in line e.g. with German Nuclear Safety Standard KTA 3504.

§ Setting the torque switch

§ Measurement of actuator speed

§ Calibration and determination of characteristic curves:

Page 40: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 40

Evaluation of Bench Test Measurements

Torque Measurement

Active power Measurement

Torque switch signal↑ Power

Torque→

Power as functionof torque

Page 41: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 41

C)

What can be Derived from Electrical Measurement ?

§Active Power minus losses on cables and stator gives the Air-Gap Power.

§Air-Gap Power is proportional to motor torque.

§By use of bench test characteristic curves, actuator output torque can be quantified later.

§ If the rigidity of the valve is known, the final stem thrustcan be calculated out of the stressing time.

§Trending and statistical comparison of similar MOVs.

Page 42: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 42

Baseline Measurement - Stem Thrust

Frate

Fgradient

Direct measurement ofstem thrust with verification of

- thrust rate - maximum stem thrust - dynamic inertia

Page 43: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 43

D)

What can be Derived from Electrical Measurement ?

§Active Power minus losses on cables and stator gives the Air-Gap Power.

§Air-Gap Power is proportional to motor torque.

§By use of bench test characteristic curves, actuator output torque can be quantified later.

§ If the rigidity of the valve is known, the final stem thrustcan be calculated out of the stressing time.

§Trending and statistical comparison of similar MOVs.

Page 44: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 44

Long-Term Trending of Evaluation Results

Long-term trend monitoring indicates upcoming

out-of-limits condition

Upper and lower limitsUpper and

lower limits

Page 45: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 45

Comparison of Similar MOVs

Page 46: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 46

Part 5:

Conclusion

Page 47: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 47

Conclusion

§ Modern monitoring methods with measurements fromMCC can replace traditional in-situ measurements.

§ Condition Based Maintenance (CBM) needs more frequent information about condition of components than other maintenance strategies.

§ CBM (or maintenance planning !) can help to improve plant safety and availability.

§ CBM can also reduce costs

Page 48: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 48

§ Germany: NPP Neckarwestheim (KWU PWR), 2 units, together 1500 MOVs with online monitoring.

§ Finland: New EPR at Olkiluoto (OL3),online monitoring of 600 MOVs and 100 SOVs.

§ Germany: NPP Grohnde (KWU PWR), 800 SIPLUG sockets, 20 mobile SIPLUGs.

§ Switzerland: NPP Beznau 1+2 (Westinghouse PWR)250 SIPLUG sockets, 20 mobile SIPLUGs. 100 SOV sockets.

§ Others in Germany: KKP 1+2 (500/50), KKB (200/10), KKK (200/10)KGG, KKE, KKG: special equipment based on SIPLUG.

§ Others worldwide: Angra-2 (Brazil), 100 sockets, 10 SIPLUGs,Smolensk (Russia) 15 sockets, 4 SIPLUGs,Trillo (Spain) 4 Current-Clamp-SIPLUGs

The tools SIPLUG® and ADAM® are in operation at the following plants:

Page 49: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 49

The End

Moving Towards Condition Based Maintenance

of Valves and Actuators

Peter Brückner

AREVA NP GmbHValve Diagnostic Systems SD-G

Seligenstädter Str. 100, D-63791 Karlstein, Germany

Tel.: +49 6188 780 [email protected]

Page 50: Moving Towards Condition Based Maintenance of …sites.ieee.org/npec-sc2/files/2017/06/SC-2Mgt06-1_Att5-AREVA.pdf> AREVA NP GmbH •SD-G Diagnostics and Instrumentation Karlstein,

> AREVA NP GmbH • SD-G Diagnostics and Instrumentation • Karlstein, Germany 50

Valve Diagnosis with ADAM® and SIPLUG®

Technology

The End