3
Technical Specification Position 360kW, 4Pole, 6.6kV IM1001, IC411 Description AC Induction Machine Type HXR 400LD4 Machine Category Process Performance Quantity of identical units 1 Standards IEC 34 / IS 325 Potentially Hazardous Atmosphere No Max. Ambient Temperature 50 degC Max. Altitude 1,000 m a.s.l. Documentation - Connection diagram (main and auxiliary) - Dimension drawing of machine - Manual for Induction Motors and Generators (delivered with motor) - Performance data & Current and torque in function of speed - Test report Tests and Certificates - Routine test according to ABB standard procedure Painting and corrosion protection - Surface treatment C3 - Standard industrial environment Accessories - Standard vibration acc. to IEC 60034-14 Grade A - Standard size roller bearing in DE - Bearing insulation for antifriction bearings, none - Phase segregated main terminal box - Separate star point terminal boxes for IEC-machines, normal size - RTD's (Pt-100) in stator windings, 12 pcs, 3-wire, unshielded, safe and hazardous areas - Duplex RTD's (Pt-100) in antifriction bearings, 1 pc / bearing, 3-wire, shielded, safe areas - Space heater for stator winding, 1 ph - SPM nipple for shock pulse measuring in each antifriction bearing - Fabricated copper rotor - Transport lock for bearings - Rating and Lubrication plates in English Notes, comments and deviations: 1. Please find attached provision GAD Motor shall be supplied accordingly. 2. Please arrange to send us complete belt-pulley details to confirm suitability of offered frame. Belt-pulley questionnaire is attached once again. 3. Please also arrange to send us pump torque-speed curve for our final check-up.

Motor Data Sheet 1A 1#360kW, 4Pole, 6600V

  • Upload
    asyyas

  • View
    39

  • Download
    4

Embed Size (px)

Citation preview

Technical SpecificationPosition Description Type Machine Category Quantity of identical units Standards Potentially Hazardous Atmosphere Max. Ambient Temperature Max. Altitude 360kW, 4Pole, 6.6kV IM1001, IC411 AC Induction Machine HXR 400LD4 Process Performance 1 IEC 34 / IS 325 No 50 degC 1,000 m a.s.l.

Documentation - Connection diagram (main and auxiliary) - Dimension drawing of machine - Manual for Induction Motors and Generators (delivered with motor) - Performance data & Current and torque in function of speed - Test report Tests and Certificates - Routine test according to ABB standard procedure Painting and corrosion protection - Surface treatment C3 - Standard industrial environment Accessories - Standard vibration acc. to IEC 60034-14 Grade A - Standard size roller bearing in DE - Bearing insulation for antifriction bearings, none - Phase segregated main terminal box - Separate star point terminal boxes for IEC-machines, normal size - RTD's (Pt-100) in stator windings, 12 pcs, 3-wire, unshielded, safe and hazardous areas - Duplex RTD's (Pt-100) in antifriction bearings, 1 pc / bearing, 3-wire, shielded, safe areas - Space heater for stator winding, 1 ph - SPM nipple for shock pulse measuring in each antifriction bearing - Fabricated copper rotor - Transport lock for bearings - Rating and Lubrication plates in English Notes, comments and deviations: 1. Please find attached provision GAD Motor shall be supplied accordingly. 2. Please arrange to send us complete belt-pulley details to confirm suitability of offered frame. Belt-pulley questionnaire is attached once again. 3. Please also arrange to send us pump torque-speed curve for our final check-up.

Driven equipment: 010 Pump Motor type code Motor type Mounting designation Protected by enclosure Method of cooling Insulation Standards Ambient temperature, max. Altitude, max. Duty type Temp. rise Connection of stator winding Rated output Voltage Frequency Speed Current Relat. starting current 1) Relat. starting torque Relat. maximum torque No load current Rated torque Load characteristics Load % 100 75 50 Direction of rotation Sound pressure level: (sinus supply, no load) Weight of rotor Total weight of motor Inertia rotor / load Bearings Maximum stalling time Starting time

HXR 400LD4 Squirrel cage motor IM 1001 IP 55 IC 411 Class F IEC 34 / IS 325 50 C 1000 m.a.s.l. S1 Class B (RES) Star 360 kW 6600 V 10 % 50 Hz 1487 rpm 39 A 6.0 (7.2 including IS Tolerance) 0.9 2.5 13 A 2311 Nm Current A Efficiency % Power Factor 39 95.7 0.85 30 95.6 0.82 22 95.0 0.74 Clockwise As per IS 12065 660 kg 2720 kg Approx. 12 kgm / 14 kgm Standard roller bearings 24.5 s (warm) 1.8 s (U=100%) 3.9 s (U=80 %) Number of consec. starts 3 / 2 (cold/warm) Maximum number of starts 1000 / year Warm-up time constant 60 min Cool-down time constant 260 min All motor data is subject to tolerances in accordance with IEC. Efficiency based on typical additional load losses acc. measurements.

Motor type code: HXR 400LD4 Rated output Voltage Frequency Speed Current

360 kW 6600 V 10 % 50 Hz 1487 rpm 39 A

Power Factor Rated torque Relat. starting current Relat. starting torque Relat. maximum torque

0.85 2311 Nm 6.0 0.9 2.5

Torque and Current as a Function of SpeedI, U=100%

6

3

5

2.5

4

2

I/In3 1.5

T/Tn

T, U=100% 2 1

1 Load Torque

0.5

0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

0

n/nsI, U=100% T, U=100% I, U=80% T, U=80% Load Torque