5
87045 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Technical data sheet: F00949EN01 Updated: 03/10/2012 Created: 24/09/2009 1/5 Mosaic TM LCS2 Cat. 6 RJ 45 socket CONTENTS Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92 1. GENERAL CHARACTERISTICS Category 6 RJ 45 socket for high speed transmission (Gigabit Ethernet). Designation Number of modules UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP RJ 45 socket aluminium 1 794 61 13 Cat. 6 FTP RJ 45 socket 1 765 62 13 Cat. 6 FTP RJ 45 socket aluminium 1 794 62 13 Cat. 6 STP RJ 45 socket 1 765 63 29 Cat. 6 UTP RJ45 socket anti-bacterial 1 765 81 13 Cat. 6 FTP RJ 45 socket anti-bacterial 1 765 82 18 Cat. 6 STP RJ 45 socket anti-bacterial 1 765 83 29 Cat. 6 UTP RJ 45 socket 2 765 64 18 Cat. 6 UTP RJ 45 socket aluminium 2 794 64 18 Cat. 6 FTP RJ 45 socket 2 765 65 18 Cat. 6 FTP RJ 45 socket aluminium 2 794 65 18 Cat. 6 FTP RJ 45 socket green 2 765 22 18 Cat. 6 FTP RJ 45 socket orange 2 765 23 18 765 61 765 44 765 94 CONTENTS Page 1. General characteristics............. 1 2. Presentation ..................... 2 3. Installation ...................... 2 4. Technical characteristics ........... 2 5. Connection ...................... 2 6. Overall dimensions................ 2 7. Usual connection of RJ 45 sockets . . .3 8. Standards and approvals ........... 3 9. Performance ..................... 4 Designation Number of modules UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 90° 2 765 91 13 Cat. 6 FTP RJ 45 socket 90° 2 765 92 18 Cat. 6 FTP RJ 45 socket 90° aluminium 2 794 92 18 Cat. 6 STP RJ 45 socket 90° 2 765 93 29 Cat. 6 STP RJ 45 socket 2 765 66 34 Cat. 6 UTP RJ 45 socket 45D 2 765 03 13 Cat. 6 FTP RJ 45 socket 45D 2 765 05 18 Cat. 6 STP RJ 45 socket 45D 2 765 07 46 Cat. 6 UTP RJ 45x2 socket 45D 2 765 04 34 Cat. 6 FTP RJ 45x2 socket 45D 2 765 06 34 Cat. 6 UTP 2 x RJ 45 socket 4 765 44 43 Cat. 6 FTP 2 x RJ 45 socket 4 765 46 43 Cat. 6 UTP RJ 45 safety socket 2 765 94 22 Cat. 6 FTP RJ 45 safety socket 2 765 95 22

Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

  • Upload
    dinhtu

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

87045 LIMOGES CedexTelephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88

Technical data sheet: F00949EN01 Updated: 03/10/2012 Created: 24/09/2009

1/5

MosaicTM

LCS2 Cat. 6 RJ 45 socket

CONTENTS

Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92

1. GENERAL CHARACTERISTICS

Category 6 RJ 45 socket for high speed transmission (Gigabit Ethernet).

DesignationNumber

of modules

UTP FTP STPWeight

(g)

Cat. 6 UTPRJ 45 socket

1 765 61 13

Cat. 6 UTPRJ 45 socket

aluminium 1 794 61 13

Cat. 6 FTPRJ 45 socket

1 765 62 13

Cat. 6 FTPRJ 45 socket

aluminium 1 794 62 13

Cat. 6 STPRJ 45 socket

1 765 63 29

Cat. 6 UTPRJ45 socketanti-bacterial

1 765 81 13

Cat. 6 FTPRJ 45 socketanti-bacterial

1 765 82 18

Cat. 6 STPRJ 45 socketanti-bacterial

1 765 83 29

Cat. 6 UTPRJ 45 socket

2 765 64 18

Cat. 6 UTPRJ 45 socket

aluminium 2 794 64 18

Cat. 6 FTPRJ 45 socket

2 765 65 18

Cat. 6 FTPRJ 45 socket

aluminium2 794 65 18

Cat. 6 FTPRJ 45 socket

green 2 765 22 18

Cat. 6 FTPRJ 45 socket

orange 2 765 23 18

765 61 765 44 765 94

CONTENTS Page

1. General characteristics. . . . . . . . . . . . .12. Presentation . . . . . . . . . . . . . . . . . . . . .23. Installation . . . . . . . . . . . . . . . . . . . . . .24. Technical characteristics . . . . . . . . . . .25. Connection . . . . . . . . . . . . . . . . . . . . . .26. Overall dimensions. . . . . . . . . . . . . . . .27. Usual connection of RJ 45 sockets . . .38. Standards and approvals . . . . . . . . . . .39. Performance. . . . . . . . . . . . . . . . . . . . .4

DesignationNumber

of modules

UTP FTP STPWeight

(g)

Cat. 6 UTPRJ 45 socket 90°

2 765 91 13

Cat. 6 FTPRJ 45 socket 90°

2 765 92 18

Cat. 6 FTP RJ 45 socket 90°

aluminium2 794 92 18

Cat. 6 STPRJ 45 socket 90°

2 765 93 29

Cat. 6 STPRJ 45 socket

2 765 66 34

Cat. 6 UTPRJ 45 socket

45D2 765 03 13

Cat. 6 FTPRJ 45 socket

45D2 765 05 18

Cat. 6 STPRJ 45 socket

45D2 765 07 46

Cat. 6 UTPRJ 45x2 socket

45D2 765 04 34

Cat. 6 FTPRJ 45x2 socket

45D2 765 06 34

Cat. 6 UTP2 x RJ 45 socket

4 765 44 43

Cat. 6 FTP2 x RJ 45 socket

4 765 46 43

Cat. 6 UTPRJ 45

safety socket2 765 94 22

Cat. 6 FTPRJ 45

safety socket2 765 95 22

Page 2: Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

MosaicTM

LCS2 Cat. 6 RJ 45 socket

Technical data sheet: F00949EN/01 Updated: 03/10/2012 Created: 24/09/2009

2/5CONTENTS

Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92

2. PRESENTATION

3. INSTALLATION

The mechanisms can be surface mounted or flush mounted.

They can also be mounted in Mosaic Programme trunkings, columns, floor boxes and office modules (min. depth 40 mm)

For Cat. Nos. 765 44/46, mounting in trunking only.

Rail mounting is possible using adaptor Cat. No. 802 99 (2 modules).

The mechanisms can be mounted on thin panels with adaptors.

Cat. No. 802 90 (1 modules), Cat. No. 802 91 (2 modules).

Cat. No. 802 92 (2 x 1 vertical module).

Cat. No. 765 94/95Unlocking

* Not supplied with the mechanism

**

*

1

2

3

40 mm

Identification numberUTP: SA51FTP: SA52STP: SA53

1 2

Colour code

and Contact number

Category colour code: Cat.6 blue

4. TECHNICAL CHARACTERISTICS

4.1 Material characteristicsContacts: gold/nickel, minimum thickness of gold > 0.8 µmMetal parts: bronze, nickel, platinum, goldPBT polycarbonateFor STP products the body and the spreader are made of metal alloy with a copper-nickel coating.

4.2 Electrical characteristicsBreakdown voltage 1000 VContact resistance 20 mInsulation resistance 500 M at 100 V DCConnector tested and guaranteed under PoE restrictions, IEEE 802.3af standard and PoE+, draft standard 802.3at, up to 2500 on-load connections / disconnections.

Tests are carried out with 2 simultaneous PoE+ circuits for a minimum total power of 50 W.

4.3 Mechanical characteristicsMax. number of connections and disconnections: 5 without refreshing the wiring.Endurance: 2500 movements (plug insertion/withdrawal).IK03

4.4 Climatic characteristicsTempératures d’utilisation : - 40° C to + 70° CHumid heat cycle 21 days

5. CONNECTION

L1

L3

L2L1 90 mL2 5 mL3 5 m

45

45

765 03/05/07/22/23/64/65/66/91/92/93/94/95 794 64/65/91/92

22,5

45

765 61/62/63/81/82/83 794 61/62

765 03/05/07 765 04/06

45

45

45

45

6. OVERALL DIMENSIONS

Front view:

Page 3: Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

MosaicTM

LCS2 Cat. 6 RJ 45 socket

Technical data sheet: F00949EN/01 Updated: 03/10/2012 Created: 24/09/2009

3/5CONTENTS

Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92

6. OVERALL DIMENSIONS (cont.)

Side view:

7. USUAL CONNECTION OF RJ 45S

Accepts the following cable connectors:RJ11 (4 contacts), RJ12 (6 contacts), RJ45 (9 contacts).

Double colour code EIA - TIA 568 A and B on terminals:- UTP 8 contacts- FTP 9 contacts- STP 9 contacts 360° screen

Conductors supported:- Single-wire: 0.5 to 0.65 mm, AWG 22 to 25- Multiple-wire: AWG 26- Polyethylene conductor insulation: max Ø with insulation 1.58 mm

EIA 568 A EIA 568 B

7. USUAL CONNECTION OF RJ 45S (cont.))

RJ 45 connectors are equipped with a locking nut that does not require the use of a specific tool and which enables re-cabling in the event of error.

This system allows the wire pairs to be spread easily before mounting them on the connector.

Spreading cables ensures that each pair is separated by the specified 13 mm.Spreading pairs by 90° in relation to the cable ensures optimum performance.

8. STANDARDS AND APPROVALS

Compliant with standards: ISO/IEC 11801 Edition 2 CENELEC EN 50173-1 2007 ANSI/EIA/TIA 568-C.2 IEC series 60603-7

5

3

4

OK

1 2

106.3

45

765 44/46

31

765 07/63/66/83/93

765 03/04/05/06/22/23/44/61 765 62/64/65/81/82/91/92/94 794 61/62/64/65/92

25,2 25,1 15,6

765 03/04/05/06

27,2 15,6

765 07

Page 4: Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

MosaicTM

LCS2 Cat. 6 RJ 45 socket

Technical data sheet: F00949EN/01 Updated: 03/10/2012 Created: 24/09/2009

4/5CONTENTS

Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92

9. PERFORMANCE

9.1 Component performance (RJ 45 connectors)Return loss

Attenuation

NEXT (Near end Crosstalk Attenuation)

9. PERFORMANCE (cont.)

9.1 Component performance (RJ 45 connectors) (cont.)FEXT (Far end Crosstalk Attenuation)

9.2 Performance of permanent link with F/UTP cableReturn loss

Attenuation

0 dB

20

40

60

80

100 dB1 MHz 10 100

0 dB

20

40

60

80

100 dB1 MHz 10 100

0 dB

20

40

60

80

100 dB1 MHz 10 100

0 dB

0.1

0.2

0.3

0.4

0.5 dB1 MHz 10 100

0 dB

20

40

60

80

100 dB1 MHz 100 300 MHz200

0 dB

20

40

60

80

100 dB1 MHz 100 300 MHz200

300 MHz

300 MHz

300 MHz

300 MHz

Page 5: Mosaic LCS2 Cat. 6 RJ 45 socket - DOC DIFFdocdif.fr.grpleg.com/general/legrand-exp/NP-FT-GT/F00949EN-01.pdf · UTP FTP STP Weight (g) Cat. 6 UTP RJ 45 socket 1 765 61 13 Cat. 6 UTP

MosaicTM

LCS2 Cat. 6 RJ 45 socket

Technical data sheet: F00949EN/01 Updated: 03/10/2012 Created: 24/09/2009

5/5CONTENTS

Référence(s) : 765 03/04/05/06/07/22/23/44/46/61/62/63/64 765 65/66/81/82/83/91/92/93/94/95 794 61/62/64/65/92

9. PERFORMANCES (cont.)

9.2 Performance of permanent link with F/UTP cable (cont.)ELFEXT (Equal Level End Crosstalk Attenuation)

Delay skew

9. PERFORMANCE (cont.)

9.2 Performance of permanent link with F/UTP cable (cont.)NEXT (Near end Crosstalk Attenuation)

PS NEXT (Power Sum NEXT)

ACR (Attenuation to Crosstalk Ratio)

0 dB

20

40

60

80

100 dB1 MHz 100 300 MHz200

0 dB

20

40

60

80

100 dB1 MHz 100 300 MHz200

0 dB

20

40

60

80

100 dB1 MHz 100 300 MHz200

0 ns

20

40

60

80

100 ns1 MHz 100 300 MHz200

-20 dB

0

20

40

60