MorphoAccess® 500 Series

Installation Guide

Produced by Morpho Copyright ©2012 Morpho

www.morpho.com

MorphoAccess 500 Series Installation Guide

SSE-0000053018-07

April 2012

MA 500+ Series

OMA 500 Series

MA 500 Series

Page 2: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

2 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07

TTaabbllee ooff CCoonntteennttss

Introduction ................................................................................................................... 3

Scope of the document ................................................................................................... 4

Safety instructions .......................................................................................................... 5

Europe information: 5

USA information 6

Canadian information 6

General description ........................................................................................................ 7

MA 500 / MA 500+ Series 7

OMA 500 Series 8

MA 500 / MA 500+ SERIEs Installation procedure ............................................................ 9

Stage 1: Drilling the mounting holes 9

Stage 2: Mounting the metal chassis assembly 10

Stage 3: Connecting the chassis assembly to the cover assembly 11

Stage 4: Closing MorphoAccess® 12

OMA 500 SERIES Installation procedure .......................................................................... 14

Stage 1: Drilling the mounting holes 14

Stage 2: Fixing 15

Stage 3: Cabling 15

Stage 4: Closing 15

Electrical interface .......................................................................................................... 16

MA 500 / MA 500+ Series: New Terminal block board wiring 16

MA 500 Series: Old Terminal block board wiring 17

OMA 500 Series rear view and cables 18

USB Flash drive installation 20

Wi-Fi™ USB dongle installation 21

Power Supply source 22

Wiegand output wiring 23

Data Clock output wiring 23 The controller supports neither LED1 nor LED2 signals 24 The controller supports only LED1 signal 24 The controller supports LED1 and LED2 signals 24

Wiegand input wiring 26

Data Clock input wiring 27

COM RS422 serial port 28

Page 3: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Table of Contents

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 3 April 2012

COM RS485 serial port 28

Ethernet wiring 29

Output relay and security switches 30 Anti-theft and tamper switches ratings 31 Relay ratings 32

User interface ................................................................................................................. 33

MorphoAccess® 500 series technical characteristics ........................................................ 34

Man Machine Interface 34

Biometry 34

Peripherals interfaces 34

Power supply 35 Consumption: 35 Power Over Ethernet compatibility (IEEE802.3 af): 35

Size and weight 35

Environment conditions 36

Recommendations .......................................................................................................... 37

Areas containing combustibles 37

General precautions 37

Specific precautions for radio terminals 37

Ethernet connection 38

Date / Time synchronization 38

Cleaning precautions 38

Warning 38

Appendix 1 – Finger placement recommendations .......................................................... 39

Appendix 2 - Drilling template......................................................................................... 40

MA500 / MA 500+ SERIES 40

OMA 500 SERIES 41

Support .......................................................................................................................... 42

Related documents 42 Administrator Information 42 Developer Information 42 Support Tools 43

Contacts 44 Customer service 44 Hotline 44

Page 4: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Table of Figures

4 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

TTaabbllee ooff FFiigguurreess

Figure 1: OMA500 rear view .................................................................................................... 14

Figure 2: MA500 connectors (current version) ........................................................................ 16

Figure 3: MA500 connectors (previous version) ...................................................................... 17

Figure 4: OMA500 wiring ......................................................................................................... 18

Figure 5: OMA500 Internal wiring (I/O Board version 2) ......................................................... 19

Figure 6: USB flash drive installation ........................................................................................ 20

Figure 7: Wi-Fi™ USB dongle installation ................................................................................. 21

Figure 8: Security Loop ............................................................................................................. 31

Figure 9: Electric latch wiring (sample) .................................................................................... 32

Page 5: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Revision History

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 5 April 2012

RReevviissiioonn HHiissttoorryy

Date Firmware Description

February 2011 (rev 07)

2.13 Modification of company logo and name (Morpho)

June 2011 2.14 Upgrade LED IN feature description

April 2012 3.3 Update USB flash drives description

Page 6: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Introduction

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 3 April 2012

IInnttrroodduuccttiioonn

Congratulations for choosing the MorphoAccess®1 Automatic Fingerprint Recognition Terminal. MorphoAccess® provides an innovative and effective solution for access control applications using Fingerprint Verification or/ and Identification.

Among a range of alternative biometric techniques, the use of finger imaging has significant advantages: each finger constitutes an unalterable physical signature which develops before birth and is preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins.

The MorphoAccess® integrates Morpho image processing and feature matching algorithms (MorphoSoft™ and MorphoImaging™). This technology is based on lessons learned during more than 20 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records.

We believe you will find the MorphoAccess® fast, accurate, easy to use and suitable for physical access control.

The MorphoAccess® offers the following advantages:

high quality optical sensor (IQS certified),

supports multiple input/output interfaces used in the physical access control industry,

Local Area Network interface for easy interaction with other host systems ; LAN and WLAN possibilities (Wi-Fi™ as an option),

compact size for easy installation and integration into your available office space,

intuitive man machine interface with keyboard and display, that is easy to use in both setup and operational modes,

open architecture, with dedicated applications implemented via MorphoAccess® 100, J, VP and 500 Series Software Development Kit.

To ensure the most effective use of your MorphoAccess® terminal, we recommend that you read this Installation Guide thoroughly.

1 The Morpho logo and trademark are the property of Morpho.

All other trademarks or product names are trademarks or product names of the respective title holders.

Wi-Fi™ is a registered mark of the Wi-Fi™ Alliance

Page 7: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Scope of the document

4 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

SSccooppee ooff tthhee ddooccuummeenntt

This guide relates to the use of MorphoAccess® 500 Series terminals. MorphoAccess® 500 Series is a generic appellation which gathers MorphoAccess® terminals belonging to MA 500+ series, OMA 500 series and MA 500 series. Corresponding list of products is depicted in the table below.

Biometrics

Contactless Smartcard Reader

False Finger

Detection Outdoor

MIFARE® DESFire®

MA 500+ Series

MA 500+

MA 520+ D

MA 521+ D

OMA 500 Series

OMA 520 D

OMA 521 D

OMA 520

OMA 521

MA 500 Series

MA 500

MA 520

MA 521

Page 8: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Safety instructions

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 5 April 2012

SSaaffeettyy iinnssttrruuccttiioonnss

The installation of this product should be made by a qualified service technician and should conform to all local codes.

It is strongly recommended that a class II power supply at 12V ±5% and 1.5A. min is used in accordance with Safety Electrical Low Voltage (SELV) parameters. The 12V power supply cable length should not exceed 5 meters.

This product may be installed with a power supply conforming to EN60950, in accordance with the NEC Class 2 requirements; or supplied by a listed EN60950 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1.5A minimum.

In case of “Power Over Ethernet” use, the POE hub or switch features has to be conformed with IEEE 802.3-af standard. An insulation greater than 2000V is provided between terminal and Ethernet network.

In case of building to building connection it is recommended to connect 0V to ground. This ground (ground security reference) cable must be connected with the terminal block board fixation screw marked with the universal ground symbol (see p16).

EEuurrooppee iinnffoorrmmaattiioonn::

Morpho hereby declares that the MorphoAccess® has been tested and found compliant with the following listed standards as required by the EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998), EN300-330 (1999) and by the low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000).

These terminals are Class A devices. In a residential environment, these devices may cause interference. In this case, the user is encouraged to try to correct the interference with appropriated measures such as:

reorient or relocate the receiving antenna,

increase the separation between the equipment and receiver,

connect the equipment into an outlet on a circuit different from that to which the receiver is connected,

consult the dealer or an experienced radio/TV technician for help.

Page 9: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Safety instructions

6 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

UUSSAA iinnffoorrmmaattiioonn

Responsible Party: Morpho, Le Ponant de Paris, 27, rue Leblanc – F 75512 PARIS CEDEX 15 – FRANCE

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 Class A of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found compliant with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, which leads the user to correct the interference at his own expense.

CCaannaaddiiaann iinnffoorrmmaattiioonn

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de Classe A est conforme à la norme NMB-003 du Canada.

Page 10: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

General description

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 7 April 2012

GGeenneerraall ddeessccrriippttiioonn

MMAA 550000 // MMAA 550000++ SSeerriieess

MorphoAccess® supplies:

1 Cover assembly with Chassis and 2 Secured screws for fixation,

1 Secured screwdriver Torx 20,

1 Chassis fixation kit (4 fixations and screws, 1 anti theft block).

Display

128 x 64 dots

Function keys

Keyboard Card reader

(depending on MA version)

Sensor

Cable entry

Mounting keyholes

Anti-theft

entry

Metal chassis

Page 11: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

General description

8 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

OOMMAA 550000 SSeerriieess

Outdoor MorphoAccess® supplies:

1 Cover assembly with chassis and protective visor,

1 Secured screwdriver Torx 10,

1 Chassis fixation kit (4 fixations and screws).

Display

128 x 64 dots

Function keys

Keyboard Card reader

Sensor

4 Mounting slots

Protective visor

Page 12: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MA 500 / MA 500+ SERIEs Installation procedure

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 9 April 2012

MMAA 550000 // MMAA 550000++ SSEERRIIEEss IInnssttaallllaattiioonn pprroocceedduurree

SSttaaggee 11:: DDrriilllliinngg tthhee mmoouunnttiinngg hhoolleess

Mounting and cable entry hole location (rear view)

a) Using the dimensional drawing in Appendix 3, drill 2 holes for the mounting keyholes screws so that the cable entry is in a suitable position for cabling.

b) Drill the hole for the third screw in the centre of the slot so that it is possible to correct the position later, if necessary.

c) The mounting screws must be 5 mm diameter maximum.

Page 13: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MA 500 / MA 500+ SERIEs Installation procedure

10 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

SSttaaggee 22:: MMoouunnttiinngg tthhee mmeettaall cchhaassssiiss aasssseemmbbllyy

a) Disconnect the ribbon cable between the motherboard and the terminal block board so that the assembly shown above can be detached from the rest of MorphoAccess®.

b) Pass the connecting cables through the cable entry.

c) Position the chassis assembly against the wall using the two screws in the mounting keyholes.

d) Hold the chassis in place with a screw through the mounting slot.

e) Adjust the position, and fix in place by tightening all three screws.

f) Adjust the anti theft block into the hole designed for it, and fix in place the last and fourth screw.

Check that nothing is interfering with the anti theft switch (opto component) and the anti theft block.

g) Connect cables to terminal blocks with adequate torque conformed to screw dimensions (see the detailed instructions in the following sections)

Be sure during manipulation that the power supply from the electrical source is off.

Terminal block board

Anti theft switch

Cut-out for cable entry

Cable entry

Chassis bold receivers

Page 14: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MA 500 / MA 500+ SERIEs Installation procedure

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 11 April 2012

SSttaaggee 33:: CCoonnnneeccttiinngg tthhee cchhaassssiiss aasssseemmbbllyy ttoo tthhee ccoovveerr aasssseemmbbllyy

Ribbon cable connector location

Position of the ribbon cable as the case is closed

Tamper switch

Motherboard/terminal block board ribbon cable connector

Cover assembly

Chassis assembly

Page 15: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MA 500 / MA 500+ SERIEs Installation procedure

12 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

SSttaaggee 44:: CClloossiinngg MMoorrpphhooAAcccceessss®®

Chassis assembly

The ribbon cable must be folded as shown so that the

case closes easily without damaging the cable

Cover assembly

When the ribbon cable has been connected between the two assemblies (see stage 3), the cover assembly is fitted to the chassis assembly.

1. The lip on the cover slides behind the chassis, to fit over the catch shown on the diagram above.

2. The cover is fitted onto the chassis by rotating it.

Lip

Catch for the cover assembly lip

Page 16: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MA 500 / MA 500+ SERIEs Installation procedure

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 13 April 2012

Fit the two M4x16 assembly screws. Use screwdriver TORX 20

Assembled MorphoAccess®

Page 17: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

OMA 500 SERIES Installation procedure

14 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

OOMMAA 550000 SSEERRIIEESS IInnssttaallllaattiioonn pprroocceedduurree

SSttaaggee 11:: DDrriilllliinngg tthhee mmoouunnttiinngg hhoolleess

Mounting hole location (rear view)

Figure 1: OMA500 rear view

a) Using the dimensional drawing in Appendix 3, drill holes for the four mounting bolts, vertically centered within the four slots.

b) The mounting bolts must be 5 mm diameter maximum.

Page 18: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

OMA 500 SERIES Installation procedure

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 15 April 2012

SSttaaggee 22:: FFiixxiinngg

a) Remove protective visor (4 small caps at each corner) before fixing the assembly.

b) Remove the 4 small caps at each corner of the protective visor, with a small screw driver.

c) Remove the 4 screws, with T10 screw driver supplied.

d) Adjust the assembly in front of the 4 holes.

e) Fix the 4 mounting bolts (2 in upper zone, 2 in lower zone).

SSttaaggee 33:: CCaabblliinngg

a) Connect necessary cables to user wires (see the detailed instructions in the following sections).

SSttaaggee 44:: CClloossiinngg

a) Mount protective visor with 4 screws and T10 screw driver.

b) Put the 4 small caps.

Page 19: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

16 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

EElleeccttrriiccaall iinntteerrffaaccee

MMAA 550000 // MMAA 550000++ SSeerriieess:: NNeeww TTeerrmmiinnaall bblloocckk bbooaarrdd wwiirriinngg

Figure 2: MA500 connectors (current version)

Be sure during terminal installation and connections that Electric Static Discharge (ESD) is prevented by connecting installation man to ground security.

Power supply source External +12V DC

or Power Over Ethernet

Anti theft opto Wiegand IN

Dataclock IN

Ethernet Terminal block

or RJ45

Wiegand OUT

Dataclock OUT

COM

RS422 / RS485

Relay Tamper switch

Anti theft switch

Ground security reference

Page 20: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 17 April 2012

MMAA 550000 SSeerriieess:: OOlldd TTeerrmmiinnaall bblloocckk bbooaarrdd wwiirriinngg

Figure 3: MA500 connectors (previous version)

Anti theft opto Wiegand IN

Dataclock IN

COM

RS422 / RS485

Relay Tamper switch

Anti theft switch

Wiegand OUT

Dataclock OUT

Ground security

reference

Ethernet Terminal block

or RJ45

Power supply source External +12V DC

or Power Over Ethernet

Page 21: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

18 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

OOMMAA 550000 SSeerriieess rreeaarr vviieeww aanndd ccaabblleess

Figure 4: OMA500 wiring

Wiring (cables colors and cables positions) is not exactly the same as previous OMA 200/300 Series.

In order to comply with EMC directives (See p 6), all cables coming from Access Control system must be shielded.

Both shield wires (cable, AC system cable) must be tied together.

Shield wire from cable is the wire without insulation.

Ethernet RJ45

Power Supply

source

Tamper switch Relay

Wiegand DataClock

COM RS422/ 485

Page 22: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 19 April 2012

If troubleshooting, please check that internal connections are similar to the following image:

Figure 5: OMA500 Internal wiring (I/O Board version 2)

Page 23: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

20 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

UUSSBB FFllaasshh ddrriivvee iinnssttaallllaattiioonn

An USB Flash drive may be installed into the terminal for configuration, log file collect or software update.

USB Flash drive installation has to be done when power is on.

USB Flash drive has to be plugged on the upward USB connector, as on the following image:

Figure 6: USB flash drive installation

The supported maximum capacity and file system format of the USB Flash drive depends upon the MorphoAccess® firmware version:

MorphoAccess® FW version

Maximum USB Flash drive capacity

Supported file system

< 3.2.10 1 GB FAT 16

≥ 3.2.10 16 GB FAT 16, FAT 32

Page 24: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 21 April 2012

WWii--FFii™™ UUSSBB ddoonnggllee iinnssttaallllaattiioonn

Only Morpho WI-FI™ USB dongle (Reference 189930722) may be installed into the terminal for WLAN (Wireless Local Area Network) operation.

WI-FI™ USB dongle has to be plugged on the upward USB connector, as on the following image:

Figure 7: Wi-Fi™ USB dongle installation

Page 25: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

22 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

PPoowweerr SSuuppppllyy ssoouurrccee

MA 500 / MA 500+ Series OMA 500 Series

Power cable

1 Block 1 +12V In Positive 12 Volts, power supply Red

2 Block 2 GND/ALIM In Ground power supply Black

Ground In Ground security reference yellow/green

External power supply:

Must conform to CEE/EEC EN60950 standard

9V to 16 Volts ± 5% (regulated) 1.5 Amp minimum (peak)

Power may come from a 12Volt Wiegand power supply, conforming to the Security Industry Association's Wiegand standard March 1995, able to deliver 9 Watts.

In standard operating activity, typical power consumption is 4.5 Watts.

In extreme temperature conditions, with all options (USB Flash drive, 12V output for Wiegand in), maximum power consumption is up to 9 Watts.

These terminals make use of POE functionality; if Ethernet network is POE compatible, power supply may come from Ethernet wiring.

For systems placed in other building than supervisor one's, the electrical security is guaranteed with a "ground connection" to the terminal.

For a higher susceptibility level, we recommend to the installer to connect a "ground connection" to the terminal.

MA 500 / MA 500+ Series: A cable terminal connected to "ground security reference" must be tied to the fixation designed for (see p. 16-17).

OMA 500 Series: the yellow/green wire in power supply cable must be connected to "ground security reference".

Page 26: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 23 April 2012

WWiieeggaanndd oouuttppuutt wwiirriinngg

MA 500 / MA 500+ Series OMA 500 Series

Wiegand Dataclock cable

1 Block 1 D0 Out Wiegand D0 Green

2 Block 2 D1 Out Wiegand D1 White

3 Block 3 LED1 In Wiegand LED IN 1 (option) Brown

4 Block 4 LED2 In Wiegand LED IN 2 (option) Grey

5 Block 5 GND Ground for Wiegand Black

Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible.

DDaattaa CClloocckk oouuttppuutt wwiirriinngg

MA 500 / MA 500+ Series OMA 500 Series

Wiegand Dataclock cable

1 Block 1 D0 Out Data ( 5V TTL ) Green

2 Block 2 D1 Out Clock ( 5V TTL ) White

3 Block 3 LED1 NC NC

4 Block 4 LED2 NC NC

5 Block 5 GND Ground for Dataclock Black

The use of LED1 and LED2 wires is described in the paragraphs below.

Page 27: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

24 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

TThhee ccoonnttrroolllleerr ssuuppppoorrttss nneeiitthheerr LLEEDD11 nnoorr LLEEDD22 ssiiggnnaallss

When the access controller has no relay contact to provide an answer to the MorphoAccess® terminal, then the decision to emit either the “access granted” signal or the “access denied” signal is taken by another way. It is either the MorphoAccess® terminal itself that decide, or it waits for the access controller answer through the local area network (TCP), or on the serial port in (RS422).

It is strongly recommended to disable the LED IN feature, to avoid any interference on MorphoAccess terminal behavior.

TThhee ccoonnttrroolllleerr ssuuppppoorrttss oonnllyy LLEEDD11 ssiiggnnaall

When the access controller has only one relay contact which is dedicated to the “access granted” answer, this one must be connected between the LED1 and GND wires. The LED1 wire is set to the low level by closing the contact between the LED1 and the GND wires), and it means “access granted".

The MorphoAccess® terminal uses the timeout of the wait for a low level on the on LED1 wire or LED2 wire as "access denied” answer.

To minimize at most the waiting time of the user, the MorphoAccess® terminal timeout value, must be adjusted to a value a little bit higher than the maximal value of the controller response time.

Warning: if the LED2 wire is connected, it must be constantly maintained in the high state.

TThhee ccoonnttrroolllleerr ssuuppppoorrttss LLEEDD11 aanndd LLEEDD22 ssiiggnnaallss

When the controller supports one relay contact for each of the possible answers then:

the « access granted » contact must be connected between the LED1 and the GND wires of the terminal

the « access denied » contact must be connected between the LED2 et the GND wires of the terminal.

The MorphoAccess® terminal considers that:

The answer of the controller is "access granted", when the controller puts the LED1 wire to the low state (by closing a contact between the LED1 and the GND wires), and leaves the LED 2 wire to the high state.

The answer of the controller is "access denied", when the controller puts the LED2 wire to the low state (by closing a contact between the LED2 and the GND wires), whatever is the state of the LED 1 wire.

Page 28: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 25 April 2012

The MorphoAccess® terminal also considers that the answer of the controller is "access denied" in case of time-out while expecting for a closure between LED1 and GND wires, or between LED2 and GND wires.

Page 29: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

26 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

WWiieeggaanndd iinnppuutt wwiirriinngg

MA 500 / MA 500+ Series OMA 500 Series

Wiegand Dataclock cable 1 Block 1 D0 In Wiegand D0 Blue

2 Block 2 D1 In Wiegand D1 Yellow

3 Block 3 LED Out Wiegand LED OUT 1 (option) Orange

4 Block 4 +12V Out 12 Volts Power output (150mA max) Red

5 Block 5 GND Ground for Wiegand Black

Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible. For open drain output peripheral see Note A.

Page 30: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 27 April 2012

DDaattaa CClloocckk iinnppuutt wwiirriinngg

MA 500 / MA 500+ Series OMA 500 Series

Wiegand Dataclock cable 1 Block 1 D0 In Data (5V TTL) Blue

2 Block 2 D1 In Clock (5V TTL) Yellow

3 Block 3 LED NC NC

4 Block 4 +12V Out 12 Volts Power output (150mA max) Red

5 Block 5 GND Ground for Dataclock Black

Note A: In case of old I/O board (split power connector) and if your Wiegand/Dataclock peripheral has open drain outputs, a signal adaptation is required, as follows:

D0 Wiegand IN signal:

Pull up 10K Ohms to +12Volts

Pull down 4.7K Ohms to GND

D1 Wiegand IN signal:

Pull up 10K Ohms to +12Volts

Pull down 4.7K Ohms to GND

Page 31: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

28 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

CCOOMM RRSS442222 sseerriiaall ppoorrtt

MA 500 / MA 500+ Series OMA 500 Series

COM RS422/RS485 cable

1 Block 1 GND Ground for RS422 Grey or White

2 Block 2 Tx- Out RS422 Negative Transmit Orange

3 Block 3 Tx+ Out RS422 Positive Transmit Orange/White

4 Block 4 Rx- In RS422 Negative Receive Green

5 Block 5 Rx+ In RS422 Positive Receive Green/White

RS422 interface is a full duplex communication.

CCOOMM RRSS448855 sseerriiaall ppoorrtt

MA 500 / MA 500+ Series OMA 500 Series

COM RS422/RS485 cable

1 Block 1 GND Ground for RS485 Grey or White

2 Block 2 Tx- Out RS485 Negative Transmit Orange

3 Block 3 Tx+ Out RS485 Positive Transmit Orange/White

4 Block 4

5 Block 5

RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and ground reference signals are necessary.

Depending on the RS485 network, an impedance adaptation may be required.

For farthest terminal, a 120-Ohms resistor termination may be added to the terminal, by strapping block 2 and block 3.

Page 32: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 29 April 2012

EEtthheerrnneett wwiirriinngg

2 ways for Ethernet wiring:

Terminal block connection (MA 500 / MA 500+ Series) only

RJ 45 cabling connection

MA 500 / MA 500+ Series OMA 500 Series

Ethernet cable

1 Block 1 RX- In Receive negative Ethernet RJ45 Pin 6

2 Block 2 RX+ In Receive positive Ethernet RJ45 Pin 3

3 Block 3 TX- Out Transmit negative Ethernet RJ45 Pin 2

4 Block 4 TX+ Out Transmit positive Ethernet RJ45 Pin 1

5 Block 5 GND Ground for shield Ethernet RJ45 Pin 7

RJ45 Pinout

Signals EIA/TIA T568B

color EIA/TIA T568A

color Corel L120

color

1 TX(+) Transmit Data Plus White Orange White Green Grey

2 TX(-) Transmit Data Minus Orange Green White

3 RX(+) Receive Data Plus White Green White Orange Pink

4 No connection Blue Blue Orange

5 No connection White blue White blue Yellow

6 RX(-) Receive Data Minus Green Orange Blue

7 Ground protection (option) White Brown White Brown Purple

8 No connection Brown Brown Brown

Page 33: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

30 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

RJ45 plug pinout is compliant with 10/100 base T, IEEE802.3 Specification.

RJ45 plug and Ethernet terminal block connections are compliant with Power Over Ethernet (POE) IEEE802.3 af Specification. See details on page 27.

Default IP address from factory setting is: 134.1.32.214

OOuuttppuutt rreellaayy aanndd sseeccuurriittyy sswwiittcchheess

MA 500 / MA 500+ Series OMA 500 Series

Switch/relay cable

1 Block 1 CRO Contact relay normally open Red

2 Block 2 CRC Contact relay normally closed Orange

3 Block 3 CR Contact relay common Yellow

4 Block 6 TSW2_1 Tamper switch Contact 1 White

5 Block 7 TSW2-0 Tamper switch Contact 0 Green

6 Block 4 ATSW1_1 Anti theft switch Contact 1 Not available

7 Block 5 ATSW1_0 Anti theft switch Contact 0 Not available

Ground Not connected Black (*)

(*): For this interface connection, it is not recommended to connect black wire to Ground. Various ground reference are not recommended.

This terminal is part of security system. In order to prevent unauthorized access into this terminal it is the customer’s responsibility to connect the tamper switch and the anti theft switch (MA 500 / MA 500+ Series only) to the physical access controller (connected mode).

Page 34: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 31 April 2012

AAnnttii--tthheefftt aanndd ttaammppeerr sswwiittcchheess rraattiinnggss

2A at 30VDC, according to the safety extra low voltage requirements (220VDC max and 125VAC max), independently of the power supply.

The tamper function is activated with the proper screw positioning, between cover and chassis.

Terminal closed: Tamper switch ON

Terminal open: Tamper switch OFF

The anti theft function is activated by the anti theft block positioning in front of the opto component (not available with OMA 500 Series).

Terminal on wall: Anti theft switch ON

Terminal out wall: Anti theft switch OFF

“Security Loop” connection example:

Figure 8: Security Loop

Page 35: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Electrical interface

32 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

RReellaayy rraattiinnggss

Resistive load:

2A at 30 VDC according to the safety extra low voltage requirements independently of the power supply.

Inductive load:

Depend of the load and the installation.

Inductive charge management requires a parallel diode for a better contact lifetime.

Connection example about electrical door locks focus:

Figure 9: Electric latch wiring (sample)

Page 36: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

User interface

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 33 April 2012

UUsseerr iinntteerrffaaccee

The MorphoAccess® operates in three operational modes: access control with identification, access control with authentication or verification, and proxy mode.

These different modes are detailed in the MorphoAccess® 500 Series User Guide.

Terminal configuration may be done locally (keyboard, USB Flash drive) or remotely (using the configuration Tool or MEMS™ software), by modifying key parameter.

For terminal management, MEMS™ software release must be at least v6.2.

MEMS™: MorphoAccess Enrolment and Management System

Page 37: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MorphoAccess® 500 series technical characteristics

34 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

MMoorrpphhooAAcccceessss®® 550000 sseerriieess tteecchhnniiccaall cchhaarraacctteerriissttiiccss

MMaann MMaacchhiinnee IInntteerrffaaccee

LCD display 128 x 64 pixels

Alphanumeric and function keyboard (12 + 4 keypad)

Color LED for information

Multi tone Buzzer

Clock: +/- 4sec / day (typical conditions), minimum 24 hours backup

BBiioommeettrryy

Based on Morpho MSO Biometric Module, FIPS IQS certified: 500dpi optical sensor

Template Data base:

3 000 persons with 2 fingers,

5 x 10 000 persons with 2 fingers and MA-X license option.

Identification: < 1.5s (1 000 persons in database)

Authentication / verification: < 1s

PPeerriipphheerraallss iinntteerrffaacceess

Ethernet 10/100 Base T for remote control mode (terminal management)

RS422 for remote control mode (terminal management)

Wiegand (output) or Dataclock ISO2 (output) or COM (RS485 2 wires) for output information.

Wiegand Input Or Dataclock Input to interface an external reader

USB host for additional configuration

Relay: 1 contact (open and closed)

Tamper switch: Internal use (alarm message) and external contact.

Anti theft: External contact (MA 500 / MA 500+ Series only)

Page 38: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MorphoAccess® 500 series technical characteristics

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 35 April 2012

PPoowweerr ssuuppppllyy

9 to 16 Volts ± 5% and 1.5A peak power supply.

Cable cross section depends on the length 0. 75mm2 recommended.

CCoonnssuummppttiioonn::

750mA maximum rms @12V (< 1.5 A peak)

350mA typical rms @12V

PPoowweerr OOvveerr EEtthheerrnneett ccoommppaattiibbiilliittyy ((IIEEEEEE880022..33 aaff))::

Class 0 or Class 3 hub/switch equipment mandatory (15.4W),

MA 500 / MA 500+ Series configurations:

POE Alternative A compliant with RJ45 and terminal blocks,

POE Alternative B compliant with RJ45 only.

OMA 500 Series configuration:

POE Alternative A compliant only.

“POE Alternative A” means power on data lines: only 2 pairs are required.

“POE Alternative B” means power on 2 extra pairs lines: 4 pairs are required.

SSiizzee aanndd wweeiigghhtt

MA 500 Series 160 x 145 x 75mm

0.800Kg

MA 500+ Series 155 x 155 x 74mm

0.800 Kg

OMA 500 Series 289 x 218 x 99mm

2Kg

Page 39: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

MorphoAccess® 500 series technical characteristics

36 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

EEnnvviirroonnmmeenntt ccoonnddiittiioonnss

Operating temperature -10°C to + 50°C.

Operating humidity 10% < RH < 80%.

Storage temperature -20°C to + 70°C.

Storage humidity RH < 95%.

Hardness MA 500 / MA 500+ Series: IP30 (indoor use only)

OMA 500 Series: IP65 (protection against rain and dust)

Light We recommend MorphoAccess® installation within controlled lighting conditions.

Avoid direct exposure of sensor to sunlight.

Avoid intensive UV light.

Page 40: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Recommendations

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 37 April 2012

RReeccoommmmeennddaattiioonnss

AArreeaass ccoonnttaaiinniinngg ccoommbbuussttiibblleess

It is strongly recommended that you do not install your MorphoAccess® in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials.

GGeenneerraall pprreeccaauuttiioonnss

Do not attempt to repair your MorphoAccess® yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty.

Use your MorphoAccess® with original accessories. Attempts to integrate the MorphoAccess® with unapproved accessories will void your warranty.

Do not use your MA 500 / MA 500+ Series terminal in damp areas (swimming pool...). Protect it from water and other liquids.

Do not expose your MorphoAccess® to extreme temperatures.

Do not expose MorphoAccess® sensor to direct sunlight. Outdoor MorphoAccess® visor is able to mask sunlight. With MorphoAccess®, a complementary visor may be added.

Due to electrostatic discharge, and depending on the environment, synthetic carpet should be avoided in areas where the MorphoAccess® has been installed.

SSppeecciiffiicc pprreeccaauuttiioonnss ffoorr rraaddiioo tteerrmmiinnaallss

It is recommended to install radio terminals (the ones equipped with a contactless smartcard reader – see section “Scope of the document”) at 30cm or more away from metallic elements, such as iron fixation or lift gate. Performances, in term of Contactless badges reading distance will decrease when metallic elements are in close proximity to the terminal.

We advise persons with pacemaker or other electronic disposals against using the fake finger detection capable versions of MorphoAccess® (see section “Scope of the document”).

Page 41: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Recommendations

38 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

EEtthheerrnneett ccoonnnneeccttiioonn

It is recommended to use a category 5 shielded cable (120Ohms). It is also strongly recommended to insert a repeater unit every 90m.

Extreme care must be taken while connecting Ethernet wire to the terminal block board since a low quality connection may strongly impact the Ethernet signal sensitivity.

It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with the Tx+/Tx- using different twisted-pair wire).

DDaattee // TTiimmee ssyynncchhrroonniizzaattiioonn

If you expect to use the MorphoAccess® for application requiring time precision we recommend that you synchronize your terminal time with an external clock at regular intervals.

The terminal clock has +/- 40.10-6 (ppm) typical time deviation at +25°C. Roughly, +/- 4 sec per day.

At +50°C, the time deviation may be up to –8 sec per day

CClleeaanniinngg pprreeccaauuttiioonnss

A dry cloth should be used, especially for fingerprint sensor.

Acid liquids, alcohol or abrasive materials are prohibited.

WWaarrnniinngg

The manufacturer cannot be held responsible if the above recommendations are not followed or if the MorphoAccess® is incorrectly used.

Page 42: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Appendix 1 – Finger placement recommendations

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 39 April 2012

AAppppeennddiixx 11 –– FFiinnggeerr ppllaacceemmeenntt rreeccoommmmeennddaattiioonnss

To ensure a good quality contact of your finger on the terminal you must leave your finger on the sensor until the sensor light is turned off.

Fingerprint Placement Fingerprint Orientation

Area containing most of the information

Fingerprint Inclination Fingerprint Rotation

Page 43: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Appendix 2 - Drilling template

40 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

AAppppeennddiixx 22 -- DDrriilllliinngg tteemmppllaattee

MMAA550000 // MMAA 550000++ SSEERRIIEESS

Scale: 1 (Real dimensions)

Anti theft block position

Page 44: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Appendix 2 - Drilling template

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 41 April 2012

OOMMAA 550000 SSEERRIIEESS

The above image dimensions do not match reality. True dimensions are in millimeters.

70

135

256

80

60

Cable Pass Through Depth : 20

Page 45: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Support

42 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

SSuuppppoorrtt

RReellaatteedd ddooccuummeennttss

AAddmmiinniissttrraattoorr IInnffoorrmmaattiioonn

MorphoAccess® 500 Series User Guide

This document describes operating mode and terminal settings

MorphoAccess® 500 Series Configuration Application User Guide

This document describes the configuration application processing

MorphoAccess® 500 Series Parameters Guide

The complete description of terminal configuration files and registry keys

This document gives also parameters default values

MorphoAccess® 500 Series Enrolment application User Guide

This document describes the local enrolment process and features

MorphoAccess® 500 Series Log viewer User Guide

This document describes the log viewer process and features

DDeevveellooppeerr IInnffoorrmmaattiioonn

MorphoAccess® Host Interface Specification

A complete description of remote management commands

MorphoAccess® Remote Messages Specification

Details how the MorphoAccess® sends the access control result to a Central Security Controller

MorphoAccess® Contactless Card Specification

This document describes the MorphoAccess® contactless card feature

Page 46: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Support

SSE-0000053018-07 Morpho document. Reproduction and disclosure forbidden. 43 April 2012

SSuuppppoorrtt TToooollss

Configuration Tool User Guide

Configuration Tool user guide, via Ethernet

USB Tool User Guide

Configuration Tool user guide, via USB Flash drive

MorphoAccess® 500 Series Upgrade Tools User Guide

Upgrade Tool user guide about firmware upgrading procedures

Terminal License Management

Download a license in MorphoAccess® using “Terminal Licence Manager.exe” PC application.

Page 47: MorphoAccess® 500 Series - IDEMIAservice.morphotrak.com/content/Documents/MA500 Series Installation Guide.pdfThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil

MorphoAccess 500 Series Installation Guide

Support

44 Morpho document. Reproduction and disclosure forbidden. SSE-0000053018-07 April 2012

CCoonnttaaccttss

CCuussttoommeerr sseerrvviiccee

Morpho

SAV Terminaux Biométriques

Boulevard Lénine - BP428

76805 Saint Etienne du Rouvray

FRANCE

Phone: +33 2 35 64 55 05

HHoottlliinnee

Morpho

Support Terminaux Biométriques

18, Chaussée Jules César

95520 Osny

FRANCE

[email protected]

Phone: + 33 1 58 11 39 19

(9H00am to 5H00pm French Time, Monday to Friday)

www.biometric-terminals.com

To access this service, please contact us in order to get your login.

Please send us an email rather than call by phone.