DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
7/6/17Plotted On:
7/6/17AS NOTED
TITL
E S
HE
ET
/ PR
OJE
CT
DAT
A
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/W
eath
erto
p/D
ropb
ox/1
080
Em
elin
e R
emod
el/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A0
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
GENERAL NOTES:
1. Architect assumes no responsibility for the completeness of plans for bid purposes prior to issuance of the building permit. The general contractor and all subcontractors shall verify all dimensions and conditions on the job site prior to beginning of construction.2. The intent of these drawings and specifications is to include all labor, materials and services necessary for the completion of all work shown prescribed or reasonably implied, but not limited to that explicitly indicated in the contract documents.3. The Architect’s approval of such shop drawings shall not relieve the General Contractor or subcontractor from responsibility for deviations from drawings or specifications unless he or she has (in writing) called the Architect’s attention to such deviations at the time of submissions, nor shall it relieve him or her of responsibility for errors of any sort in the shop drawings.4. Architect or designer as used in these documents refers to Boone Low Ratliff Architects, 157 Van Ness Avenue, Santa Cruz, CA 95060. (831) 423-1316.5. All work shall be performed in accordance with all applicable codes, regulations and ordinances having jurisdiction.6. Contractor is responsible for examining all contract documents, field conditions, and confirming that work is buildable as shown before proceeding with construction. If there are any questions regarding these or other coordination items, the contractor is responsible for obtaining a clarification from the Architect or tenant construction coordinator before proceeding with work in question or related work.7. Prior to the issuance of a building permit, the applicant shall have evidence of current Workman’s Compensation insurance coverage on file, in compliance with section 3800 of the California Labor Code.8. Dimensions on drawings are shown to faces of walls and partitions or finished face of existing walls unless noted otherwise.9. All vertical dimensions shown are to floor slab, unless otherwise indicated.10. Contractor shall verify and be responsible for all dimensions and conditions on the job and shall notify the architect of any discrepancies immediately before commencing any work.11. Contractor shall check and verify size and locations of duct openings and plumbing runs with mechanical contractor before framing walls, floors, etc.12. Install all manufactured items, materials and equipment in strict accordance with the manufacturer’s specifications.13. “Align” as used in these documents shall mean to accurately locate finish faces in the same plane.14. “Typical” or “TYP” as used in these documents shall mean that the condition is the same or representative for all similar conditions throughout, unless noted otherwise.15. Details are usually keyed and noted “typical” only once, when they first occur and are representative of all similar conditions throughout, unless noted otherwise.16. Do not scale drawings. Dimensions govern. Large scale details govern over small scale details.17. Contractor shall be responsible for the general cleaning of a job after its completion. Unused materials to be donated.18. All requests for substitutions or items specified shall be approved by Architect.19. Glass doors, adjacent panels, and all glazed openings, within 18 inches of the adjacent floor shall be of glass approved for impact hazard.20. Center of switches shall be no more than 48" above floor.21. Centerline of 15, 20 and 30 amp receptacles shall (except permanently installed baseboard heaters) not to be less than 15” above floor. Floor outlets acceptable next to sliding panels or walls and other special convenience locations. Baseboard outlets acceptable in relocatable partitions, window walls.22. Foundation construction shall incorporate recycled flyash in concrete up to 15% and form boards shall be reused.23. Joints and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weatherstripped, or otherwise sealed to limit infiltration and exfiltration.
A1.1
A2.1
A2.2
A3.1
A3.2
A3.3
A3.4
A3.5
A3.6
A3.7
A3.8
A3.9
A3.10
A3.11
A3.12
A3.13
A3.14
A3.15
A3.16
A3.17
A3.18
A3.19
A3.20
A3.21
A3.22
A4.1
A5.1
A5.2
A6.1
A6.2
A6.3
CONSTRUCTION PHASING PLAN
PROPOSED OVERALL FLOOR PLAN
EXITING AND FIRE PROTECTION PLAN
PARTIAL FLOOR PLAN
PARTIAL FLOOR PLAN
PARTIAL FLOOR PLAN
ENLARGED PLANS / INTERIOR ELEVATIONS
ENLARGED PLANS / INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
REFLECTED CEILING PLAN
DOOR / WINDOW SCHEDULES
ROOM FINISH SCHEDULE
ARCHITECTURAL DETAILS
ARCHITECTURAL DETAILS
ACCESSIBILITY DETAILS
A0 TITLE SHEET / PROJECT DATAIDM0.1
M1.0
M2.1
M2.2
M2.3
M2.4
M2.5
M2.6
M5.1
M6.1
P0.1
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P6.1
E0.1
E0.2
E1.2
E2.1
E2.2
E3.1
E4.1
E4.2
E4.3
E4.4
E5.1
NameLEGEND, SCHEDULES & NOTES - MECHANICAL
ROOF PLAN - MECHANICAL
DEMOLITION PARTIAL FIRST FLOOR PLAN WEST - MECHANICAL
DEMOLITION PARTIAL FIRST FLOOR PLAN CENTRAL - MECHANICAL
DEMOLITION PARTIAL FIRST FLOOR PLAN EAST - MECHANICAL
NEW PARTIAL FIRST FLOOR PLAN WEST - MECHANICAL
NEW PARTIAL FIRST FLOOR PLAN CENTRAL - MECHANICAL
NEW PARTIAL FIRST FLOOR PLAN EAST - MECHANICAL
CONTROL DIAGRAMS - MECHANICAL
DETAILS - MECHANICAL
LEGEND, SCHEDULES & NOTES - PLUMBING
PARTIAL FIRST FLOOR PLAN WEST - PLUMBING - DEMOLITION
PARTIAL FIRST FLOOR PLAN CENTRAL - PLUMBING - DEMOLITION
PARTIAL FIRST FLOOR PLAN EAST - PLUMBING - DEMOLITION
PARTIAL FIRST FLOOR PLAN WEST - PLUMBING - NEW
PARTIAL FIRST FLOOR PLAN CENTRAL - PLUMBING - NEW
PARTIAL FIRST FLOOR PLAN EAST - PLUMBING - NEW
DETAILS - PLUMBING
SYMBOLS, ABBREVIATIONS, LIGHT FIXTURE SCHEDULE, CODES,STANDARDS, NOTES & SHEET INDEX
CALIFORNIA ENERGY COMPLIANCE TITLE 24 (BUILDING INTERIOR)
ELECTRICAL SINGLE LINE DIAGRAM
PANEL BOARD SCHEDULES
OVERALL ELECTRICAL PLAN - BASEMENT
OVERALL ELECTRICAL PLAN - FIRST FLOOR
ELECTRICAL DEMOLITION PLAN - FIRST FLOOR
POWER AND SYSTEMS PLAN - FIRST FLOOR - AREA 1
POWER AND SYSTEMS PLAN - FIRST FLOOR - AREA 2
POWER AND SYSTEMS PLAN - FIRST FLOOR - AREA 3
ROOF POWER PLAN
MECHANICAL
M4.1 REFRIGERANT PIPING DIAGRAMS - MECHANICAL
ID NameELECTRICAL
E5.2
E5.3
E6.1
E6.2
E6.3
ELECTRICAL DETAILS
ELECTRICAL DETAILS
ELECTRICAL DETAILS
STRUCTURAL
S1 MINOR FRAMING CHANGESID Name
E1.1
E1.3 PANEL BOARD SCHEDULES
LIGHTING PLAN - FIRST FLOOR - AREA 1
LIGHTING PLAN - FIRST FLOOR - AREA 2
LIGHTING PLAN - FIRST FLOOR - AREA 3
ID Name
AD1.0
AD1.1
OVERALL DEMOLITION PLAN
OVERALL BASEMENT CEILING DEMOLITION PLAN
ARCHITECTURAL
S2 MINOR REMODEL: STRUCTURAL DETAILS
PANEL BOARD SCHEDULES
PANEL BOARD SCHEDULES
E1.4
E1.5
M0.2 TITLE 24 - MECHANICAL
22
ABBREVIATIONS
A.F.F. Above finish floorAFG Above finish gradeBD. BoardBTTM BottomC.B.C. California Bldg. CodeCL Center lineCLG CeilingCLR. ClearanceCONC. ConcreteCONT. ContinuousDBL DoubleDIM. DimensionDIM. PT Dimension pointDN DownDS. DownspoutDW DishwasherELEV. ElevationEQ. EqualF.F. Finish floorF.G. Finish gradeF.O.S. Face of studF.F.E. Finish floor elevationFL. FloorGA GaugeGC General ContractorGYP. BD. Gypsum boardHGT. HeightHM Hydronic manifoldHORIZ. HorizontalKIT KitchenMFG ManufacturedMTD MountedN.I.C. Not in contractNFPA National Fire Protection AssociationPL PlateREF RefrigeratorSIM SimilarSTL SteelT.O. Top ofTYP. TypicalTYP. MTG. Typical mounting heightVERT. VerticalWH Water heaterWTR Water
ABBREVIATIONS
A.F.F. Above finish floorAFG Above finish gradeBD. BoardBTTM BottomC.B.C. California Bldg. CodeCL Center lineCLG CeilingCLR. ClearanceCONC. ConcreteCONT. ContinuousDBL DoubleDIM. DimensionDIM. PT Dimension pointDN DownDS. DownspoutDW DishwasherELEV. ElevationEQ. EqualF.F. Finish floorF.G. Finish gradeF.O.S. Face of studF.F.E. Finish floor elevationFL. FloorGA GaugeGC General ContractorGYP. BD. Gypsum boardHGT. HeightHM Hydronic manifoldHORIZ. HorizontalKIT KitchenMFG ManufacturedMTD MountedN.I.C. Not in contractNFPA National Fire Protection AssociationPL PlateREF RefrigeratorSIM SimilarSTL SteelT.O. Top ofTYP. TypicalTYP. MTG. Typical mounting heightVERT. VerticalWH Water heaterWTR Water
ABBREVIATIONS
A.F.F. Above finish floorAFG Above finish gradeBD. BoardBTTM BottomC.B.C. California Bldg. CodeCL Center lineCLG CeilingCLR. ClearanceCONC. ConcreteCONT. ContinuousDBL DoubleDIM. DimensionDIM. PT Dimension pointDN DownDS. DownspoutDW DishwasherELEV. ElevationEQ. EqualF.F. Finish floorF.G. Finish gradeF.O.S. Face of studF.F.E. Finish floor elevationFL. FloorGA GaugeGC General ContractorGYP. BD. Gypsum boardHGT. HeightHM Hydronic manifoldHORIZ. HorizontalKIT KitchenMFG ManufacturedMTD MountedN.I.C. Not in contractNFPA National Fire Protection AssociationPL PlateREF RefrigeratorSIM SimilarSTL SteelT.O. Top ofTYP. TypicalTYP. MTG. Typical mounting heightVERT. VerticalWH Water heaterWTR Water
ABBREVIATIONS
GENERAL NOTES
VICINITY MAP
SHEET INDEXPROJECT TEAM
APPLICABLE CODESPROJECT DATA
SCOPE OF WORK
ALL CODES REFERENCED ARE TO BE USED ASAMENDED BY THE STATE OF CALIFORNIA ANDLOCAL JURISDICTION.
2016 CALIFORNIA BUILDING CODE2016 CALIFORNIA RESIDENTIAL CODE2016 CALIFORNIA GREEN BUILDING CODE2016 CALIFORNIA MECHANICAL CODE2016 CALIFORNIA PLUMBING CODE2016 CALIFORNIA FIRE CODE2016 CALIFORNIA ELECTRICAL CODE2016 CALIFORNIA ENERGY CODE, PART 6
OFFICE REMODEL AREA: 15,670 s.f.BLDG USE: Office / Outpatient Exam RoomsOCC. GROUP: B
1. OWNER: COUNTY OF SANTA CRUZ GENERAL SERVICES DEPARTMENT 701 OCEAN STREET, ROOM 330 SANTA CRUZ, CA 95060 831.454.4606
2. ARCHITECT: BOONE LOW RATLIFF ARCHITECTS, INC. 157 VAN NESS AVENUE SANTA CRUZ. CA 95060 831.423.1316 Contact: Monica M. Ratliff, LEED AP
3. MECHANICAL: 4601 W WALNUT ST# 1 SOQUEL, CA 95073 (831) 464-4320 Contact: Sean Ring
2. ELECTRICAL:60 GARDEN CT #210
MONTEREY, CA 93940 (831) 646-3330 Contact: Eldridge Bell
2. STRUCTURAL:2815 MISSION ST
SANTA CRUZ, CA 95060 (831) 459-7296 Contact: Andrew Radovan
GENERAL DRAWING NOTES:
1. SYSTEM COMPONENTS MAY BE SHOWN WITH EXAGGERATED SEPARATION FOR DRAWING CLARITY and with slightly adjusted thicknesses to match elevation reference points.
2. Multiple LAYER SYSTEM COMPONENTS MAY BE SHOWN AS A SINGLE LINE FOR DRAWING CLARITY.
3. VERIFY IN FIELD DIMENSIONS, CONFIGURATIONS AND QUANTITIES.
4. manufacturer's requirements may vary slightly.
5. DETAILS ARE DIAGRAMMATIC AND CONCEPTUAL IN NATURE TO SHOW INSTALLATION INTENT. make slight alterations and adjustments to fit components for completion of work.
1080 EMELINE FIRST FLOOR REMODELCOUNTY OF SANTA CRUZHEALTH SERVICES CENTER
1080 EMELINE AVENUESANTA CRUZ, CA 95060
1080 Emeline
REMODEL OF MOST OF THE FIRST FLOOR OF THE EXISTING1080 EMELINE BUILDING TO INCLUDE OFFICE, EXAMINATION,STORAGE, RESTROOM, CORRIDOR AND OTHER ANCILLARYSPACES AS SHOWN ON DRAWINGS. THE TWO INTERIORSTAIRWAYS AND SINGLE ELEVATOR ARE NOT INCLUDED INTHE SCOPE, NOR IS THE BEHAVIORAL HEALTH SUITE IN THENORTHEAST CORNER OF THE BUILDING. REFER TO PLANSFOR SPECIFIC EXCLUDED AREAS. RENOVATIONS TO INCLUDENEW WALLS, CEILINGS, FLOORING, INTERIOR DOORS,INTERIOR WINDOWS, PAINT, CABINETRY, SIGNAGE, PLUMBINGFIXTURES, TOILET ROOM ACCESSORIES, AND ASSOCIATEDMECHANICAL AND ELECTRICAL WORK. REFER TO PLANS ANDSPECIFICATIONS FOR COMPLETE SCOPE DESCRIPTION.
N
NOT TO SCALE1 SITE PLAN
PROJECT SITE
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
CO
NS
TRU
CTI
ON
PH
AS
ING
PLA
N
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A1.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
PHASING PLAN LEGEND
LIMITS OF PHASE I -
LIMITS OF PHASE II
LIMITS OF PHASE III
CONSTRUCTION PHASING NOTES1.) THE PROJECT SHALL BE COMPLETED IN THREE SEPARATE PHASES AS NOTED IN THE PLAN ABOVE, AND IN THE ORDER SHOWN. THE REMAINDER OF THE BUILDING NOT BEING WORKED ON WILL REMAIN OCCUPIED AND FUNCTIONAL DURING CONSTRUCTION.
2.) contractor shall erect temporary barriers before work begins on each phase to separate occupied areas from work areas. barriers shall be reviewed and approved by owner prior to commencement of work.
3.) contractor shall also post temporary exit signs and keep exit routes for occupied areas clear and obvious.
4.) contractor shall take care to adjust ducting as necessary to avoid contaminating occupied areas with dust from construction areas.
5.) small areas just outside of both exit stairs AND OUTSIDE OF THE EXISTING X-RAY ROOM will have to remain open and unobstructed throughout all phases of construction to allow the second floor to exit. contractor will coordinate with owner to schedule a time to complete work in these areas that does not occur during normal business hours.
6.) if there will be a disruption of power or other utilities to the occupied areas, contractor will give the owner 48 hours notice.
PHASE IEXITING PATH
PHASE ITEMPORARY BARRIER
PHASE IIEXITING PATH
PHASE IITEMPORARY BARRIER
PHASE IIIEXITING PATH
PHASE IIITEMPORARY BARRIER
NOTE:TEMPORARY BARRIERS TO RUN FLOOR-TO-CEILINGAND SHALL BE CONSTRUCTED OF ONE LAYER 1/2" PLYWOODOVER WOOD STUDS. BARRIERS SHALL BE INSTALLED ANDREMOVED WITHOUT DAMAGING FINISHES.
11 22201918171615141312109765432
H
G
E
D
B
A
1
E1
C1
8a 21
PLANNORTH
C
C
EXAM IBH OFFICE
W.C.
EXAM
EXAM EXAMEXAM
ORTHO
CORRIDOR
EXAM
NURSINGSUPR
IBHOFFICE
BREAKROOM
CORRIDOR
OFFICE
W.C.ISOLATION OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
CORR.
XRAY
W.C.
EXAMSUITE PROVIDER BULLPEN
CORRIDOR
STAIRN.I.C.
N.I.C. EXAM
STOR.
EXAM
EXAM
EXAM
EXAM
WOMEN'SRESTROOM
MEN'SRESTROOM
I.Z.ELEVATORS
N.I.C.
DRAWROOM
DRAWROOM
PHLEBOTOMY
STAT LAB
EXAM SUITE
REGISTRATION & WAITING
MEDS/STER/STOR WOMEN'S
RESTROOMMEETINGROOM
STAIRN.I.C.
STOR. STOR.
N.I.C.
RECEP
TIO
N
FAX
EXAM
IBHOFFICE
EXAM
BUSINESS OFFICEMED DIR
EXAM
EXAM
EXAM
EXAM
W.C.
MEN'SRESTROOM
COMP.
OFFICE
PROVIDER BULLPENHLTH CTRMGR EXAM
EXAM
PH MEDREC
EXAMEXAM
IBH OFFICE IBH OFFICE
PROVIDERBULLPEN
CHANGINGRM
RAD.OFFICE
IBHOFFICE
CORRIDOR
EXAM STE
IBHSUITEN.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
CLOS.
IBHOFFICE
EXAMSUITE
IBHOFFICE
EXAM
EXAM EXAM
EXAM
EXAM
EXAM
CLOS W.C.
W.C.
CORRIDOR
ELEC.CLOS.
CORR
CORR.
CORR.
CORR.
CORRIDOR
EXAM
CORRIDOR
CORR.MEDS/STER/STOR
WORK IN THIS PART OF CORRIDORTO BE COORDINATED WITH OWNERTO OCCUR OUTSIDE OF NORMAL BUSINESS HOURS
WORK IN THIS PART OF CORRIDORTO BE COORDINATED WITH OWNER
TO OCCUR OUTSIDE OF NORMAL BUSINESS HOURS
WORK IN THIS PART OF CORRIDORTO BE COORDINATED WITH OWNERTO OCCUR OUTSIDE OF NORMAL BUSINESS HOURS
WORK IN THIS PART OF WAITING AREATO BE COORDINATED WITH OWNERTO OCCUR OUTSIDE OF NORMAL BUSINESS HOURS
PHASE III
PHASE II
PHASE I
2
NOT TO SCALE1 CONSTRUCTION PHASING PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
PR
OP
OS
ED
OV
ER
ALL
FLO
OR
PLA
NCO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A2.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
11
SEQ1
8SE
Q10
SEQ1
4
UP
UPUP
22201918171615141312109765432
H
G
E
D
B
A
1
E1
C1
8a
RF/
EQ
1
21
RE
FRIG
RF / E
Q3FZ
/ EQ2
PLANNORTH
RF / EQ4
C
C
1A3.1
1A3.2
1A3.3
EXAM IBH OFFICE
W.C.
EXAM
EXAM EXAMEXAM
ORTHO
CORRIDOR
EXAM
NURSINGSUPR
IBHOFFICE
BREAKROOM
CORRIDOR
OFFICE
W.C.ISOLATION OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
CORR.
XRAY
W.C.
EXAMSUITE PROVIDER BULLPEN
CORRIDOR
STAIRN.I.C.
N.I.C. EXAM
STOR.
EXAM
EXAM
EXAM
EXAM
WOMEN'SRESTROOM
MEN'SRESTROOM
I.Z.ELEVATORS
N.I.C.
DRAWROOM
DRAWROOM
PHLEBOTOMY
STAT LAB
EXAM SUITE
REGISTRATION & WAITING
MEDS/STER/STOR WOMEN'S
RESTROOMMEETINGROOM
STAIRN.I.C.
STOR. STOR.
N.I.C.
RECEP
TIO
N
FAX
EXAM
IBHOFFICE
EXAM
BUSINESS OFFICEMED DIR
EXAM
EXAM
EXAM
EXAM
W.C.
MEN'SRESTROOM
COMP.
OFFICE
PROVIDER BULLPENHLTH CTRMGR EXAM
EXAM
PH MEDREC
EXAMEXAM
IBH OFFICE IBH OFFICE
PROVIDERBULLPEN
CHANGINGRM
RAD.OFFICE
IBHOFFICE
CORRIDOR
EXAM STE
IBHSUITEN.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
IBHOFFICE
N.I.C.
CLOS.
IBHOFFICE
EXAMSUITE
IBHOFFICE
EXAM
EXAM EXAM
EXAM
EXAM
EXAM
CLOS W.C.
W.C.
CORRIDOR
ELEC.CLOS.
CORR
CORR.
CORR.
CORR.
CORRIDOR
EXAM
CORRIDOR
CORR.
SEQ1
3SE
Q2
EQ6
MEDS/STER/STOR
GENERAL NOTES:1.) EXAMINATION ROOM BEDS AND CARTS ARE SHOWN FOR REFERENCE ONLY AND ARE NOT IN SCOPE OF WORK.
2.) CUBICLES, OFFICE FURNITURE, RECEPTION DESKS, AND LOBBY FURNITURE are TO BE PROVIDED AND INSTALLED BY OTHERS. THESE ITEMS ARE SHOWN FOR REFERENCE ONLY.
3.) ANY NEW ELECTRICAL OUTLETS OR SWITCHES SHOWN ON EXISTING WALLS ARE TO BE RUN WITHIN WALL AND NOT SURFACE-MOUNTED. CUT AND PATCH EXISTING DRYWALL AS NECESSARY.
4.) EQUIPMENT IN STAT ROOM, draw rooms, med/stor./ster rooms is shown for reference only and not included in scope of work. See equipment schedule on sheet a3.15 for specific items.
5.) there is existing asbestos floor tile throughout the building. This material will remain in place and be covered with new finish materials. Minimize disruption to this material and notify owner is a significant disturbance must take place prior to work.
6.) this project will be completed in three phases, and it is the contractor’s responsibility to erect construction barriers and temporary exit signage. Before commencing work on any phase, contractor to meet with owner and architect to discuss barrier and exit signage locations.
7.) EACH ROOM TO RECEIVE NEW SIGNAGE. SEE SPECIFICATIONS FOR REQUIREMENTS. SIGNAGE TO INCLUDE ROOMS THAT ARE NOT OTHERWISE IN SCOPE. CONFIRM ROOM NUMBERING WITH OWNER PRIOR TO ORDERING.
SCALE: 3/32" = 1'-0"1 PROPOSED OVERALL FLOOR PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
EX
ITIN
G A
ND
FIR
E P
RO
TEC
TIO
N P
LAN
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A2.2
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
F.E.
F.E.
F.E.
F.E
.
9A6.3
2,310 sq ft
2,502 sq ft
754 sq ft
2,527 sq ft
608 sq ft 381 sq ft
1,691 sq ft
311 sq ft
178 sq ft
645 sq ft
F.E.
F.E.
F.E.
F.E.
F.E.
existing sliding door at entranceis a breakout door
ISA
office and/or outpatient clinic area(100 gross occupant load factor)
meeting room - unconcentrated(15 net occupant load factor)
waiting room (assembly) - fixed seating(occupants determined by numberof fixed seats per cbc 1004.4)
MINIMUM 44" WIDE EXIT PATHPER CBC TABLE 1020.2
LEGEND
restrooms, stairs, and corridorincidental use
FIRE EXTINGUISHER
SIGNAGE LEGENDEXIT SIGN WITH DIRECTIONAL ARROWS INTERNALLY ILLUMINATEDIN ACCORDANCE WITH CBC 2016 1013 - SEE ELECTRICAL DRAWINGS.PROVIDE TACTILE SIGN THAT READS "EXIT ROUTE" ON WALL BELOW EXIT SIGN.
EXIT SIGN INTERNALLY ILLUMINATED IN ACCORDANCE WITH CBC 2016 1013 -SEE ELECTRICAL DRAWINGS. PROVIDE TACTILE SIGN THAT READS "EXIT"ON WALL BELOW EXIT SIGN.
PROVIDE TACTILE SIGN THAT READS "NOT AN EXIT"
PROVIDE ISA AT FRONT & REAR ENTRANCES.
PROVIDE CIRCULAR GEOMETRIC SYMBOL FOR UNISEX TOILET & BATHING FACILITY,COMPLIANT WITH CBC 11B-703.7.2.6.3.
NOTE:1. REFER TO DETAIL FOR MOUNTING HEIGHTS AND ADDITIONAL SIGNAGE REQUIREMENTS.
2. ISA = INTERNATIONAL SYMBOL OF ACCESSIBILITY.
EXIT
NOT ANEXIT
S
ISA
S
S
S
S
NOT ANEXIT
NOT ANEXIT
S
S
ISA
EXIT
SIM.
SIM.
254'
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
SCALE: 1/8" = 1'-0"1 EXITING AND FIRE PROTECTION PLAN
CONSTRUCTION TYPE VA with no automatic fire sprinkler systemTotal REMODEL Square Feet: 15,670 s.f.total floor area: 17,927 sf OCCUPANCY: B-OCCUPANCY
b occupancy includes administrative, outpatient clinic and testing laboratories
DESIGN OCCUPANT LOAD CALCULATIONS:Function Gross Area Occupancy Designof Space (s.f.) Load Factor Occupant Load
FIRST FLOOR (T1004.1.2)office, outpatient clinic and testing lab 10,773 / 100 108meeting room (unconcentrated) 311 / 15 21waiting room (fixed seating) PER cbc 1004.4 50 restrooms and corridors 2,257 incidental use 0____________________________________________________________________________________________________________TOTAL (1st FL) 179
EGRESS WIDTH FIRST FLOOR -Occupancy Width Factor (1005.3.2): 179 x (0.2") = 35.8" (Min. Required)MIN. REQUIRED WIDTH = 44" (PER CBC 1020.2)
SECOND FLOOR -Occupancy Width Factor (1005.3.2): 180 x (0.2") = 36" (Min. Required)MIN. REQUIRED WIDTH = 44" (PER CBC 1020.2)
TOTAL EXIT WIDTH REQUIRED ON FIRST FLOOR (WHICH SECOND FLOOR EXITS THROUGH) =35.8" + 36" = 71.8"
EXITING CALCULATIONSA. NUMBER OF EXITS REQUIRED : 2 Occupant Load First Floor > 49 (Table 1006.2.1)
B. DISTANCE BETWEEN EXITS FIRST FLOOR Maximum Interior Diagonal = 254' Minimum Overall Distance Allowed = 254' / 2 = 127' (Section 1007.1.1) Distance Between Exits = 130' > 127' - Complies
C. EXIT ACCESS TRAVEL DISTANCE Maximum Travel Distance Allowed = 200' (Table 1017.2) INTERIOR - Maximum Exit Path= ±145' < 200' THEREFORE Complies
D. CORRIDORS Min. Corridor Width 44" per (1020.2) one hour Fire Rated Corridor for B-Occupancy per ( 1020.1) without Fire Sprinkler System Maximum Proposed Dead End Corridor Length = 17'-10" < 20' (20' max. per abc 1020.4)
FIRE RATINGSA. FIRE-RATED EXTERIOR WALLS PER CBC 705.5 EXTERIOR WALLS DO NOT REQUIRE FIRE RATING AS THE FIRE SEPARATION DISTANCE IS >30'-0" TO THE PROPERTY LINE. 0 HOURS REQUIRED FOR B OCCUPANCY.
B. Fire PARTITIONS shall extend from the TOP OF THE foundation OR FLOOR/CEILING ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK ABOVE. see 708.4 CONTINUITY
C. OPENINGS IN FIRE PARTITIONS PER CBC TABLE 716.5, DOORS AND FIRE SHUTTER ASSEMBLIES ARE REQUIRED TO HAVE 20 MINUTE RATINGS. DOOR VISION PANELS ARE LIMITED TO MAXIMUM SIZE TESTED PER ASTM E119 AND ARE REQUIRED TO HAVE D-20 MARKING FOR GLAZING. SIDELIGHTS OR TRANSOMS ARE REQUIRED TO HAVE 45 MINUTE RATING WITH GLAZING LIMITED TO MAXIMUM SIZE TESTED PER ASTM E119, AND ARE REQUIRED TO HAVE D-H-OH-45 MARKING.
FIRE ALARMS AND DETECTION SYSTEM
1. PER CBC 907.2.2, A MANUAL FIRE ALARM SYSTEM IS REQUIRED SINCE THE BUILDING IS A"B" OCCUPANCY WITH MORE THAN 100 PERSONS ABOVE OR BELOW THE LOWEST LEVELOF EXIT DISCHARGE.
2. PER CBC 907.5.2.3, VISIBLE FIRE ALARMS ARE REQUIRED IN PUBLIC AREAS ANDCOMMON USE AREAS INCLUDING CORRIDORS, LOBBIES, MEETING ROOMS, ANDRESTROOMS.
3. PER CBC 907.5.2.1, AUDIBLE FIRE ALARMS ARE REQUIRED IN EVERY OCCUPIED SPACEWITHIN THE BUILDING. THE ALARMS SHALL BE A MINIMUM OF 15 DECIBELS ABOVE AMBIENTSOUND OR 5 DECIBELS ABOVE MAX. SOUND LEVEL WITH A DURATION OF 60 SECS MIN.MAX SOUND PRESSURE 110 DBA. IN ROOMS WITH AVE. AMBIENT NOISE GREATER THAN 95DBA, VISIBLE ALARMS TO BE PROVIDED.
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
PAR
TIA
L FL
OO
R P
LAN
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A3.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
D86
D06
D05D07D01
D20D27
D22
D30
D38
D37
D11
D18 D16 D28
D33D29
D24
D23
D26
D25
D14D15
D12
D13
D17
D31
D09
D32
D04D03D02 D08 D10
H
G
E
D
B
A
E1
C1
RF/
EQ
1
RE
FRIG
F.E.
F.E
.
C
C
5A6.1
10A6.1
17'-10
"
5'-9"
3'-0
"2'-8
"1'-
11"
2'-1
0"
20'-5"
32'-10"
8'-2"
6'-0
"
9'-4" 5'-0" 3'-3" 6'-10"
13'-8"
3'-2"
11'-3" 3'-0"
3'-5"
8'-8"
6'-4"
6'-1"12'-1" 13'-4"
10'-8" 2'-7" 4'-11" 7'-9" 18'-5" 9'-5" 11'-7"
18'-6"
8'-0" 11'-11" 7'-3" 26'-6" 12'-5"
5'-5"
7'-9
"
7'-8
"5'-4"
2'-5
"10
'-5"
1'-9"
8'-9" 4'-6" 1'-9"
11'-7" 24'-1" 10'-0" 9'-6" 2'-0"
5'-5"
4'-1"
9'-6"
14'-3" 10'-2"
32'-9"
7'-1
"4'-5"
7'-0
"
9'-6"
6'-5"
3'-6"
6'-0"
8'-0
"
8'-3"
2'-2
"
2'-9" 2'-2"
5'-8"
2'-4
"5'-10
"
3'-0" 2'-0"
3'-7"
6'-0
"
01
02
03
04 A3.6 01
02
03
04 A3.6
01
02
03
04 A3.601
02
03
04 A3.6
01
02
03
04 A3.7
01
02
03
04 A3.7
01
02
03
04 A3.7
01
02
03
04 A3.8
01
02
03
04 A3.8
01
02
03
04 A3.4
0204 A3.7
01
02
03
04 A3.13
01
02
03
04 A3.9
01
02
03
04 A3.9
01
02
03
04 A3.9
01
02
03
04 A3.9
01
02
03
04 A3.8
01
02
03
04 A3.10
01
02
03
04 A3.10
01
02
03
04 A3.10
01
02
03
04 A3.10
01
02
03
04 A3.11
01
02
03
04 A3.11
01
02
03
04 A3.12
01
02
03
04 A3.11
01
02
03
04 A3.8
2
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
22
2
2 1
2
1
2
2
2 22
2 2
2 2
2 2
2
2 2 1
3
22 2
3
3
3
3
2
3
3
5
5
5
6
2
EXAM105
IBH OFFICE110
W.C.111
EXAM112
EXAM106
EXAM109
EXAM113
ORTHO107
CORRIDOR170
EXAM102
NURSINGSUPR
115
IBH OFFICE117
BREAK ROOM118
CORRIDOR169
CORR.171
XRAY120
W.C.121
EXAM SUITE123
PROVIDERBULLPEN
126
CORRIDOR172
STAIRN.I.C.150B
N.I.C. EXAM127
STOR.171A
EXAM128
EXAM130
WOMEN'SRESTROOM
139
EXAM123C
IBH OFFICE123B
EXAM123A
W.C.124
COMP.125
PROVIDERBULLPEN
132
CHANGING RM122
RAD.OFFICE
116
IBH OFFICE114
CLOS.108
EXAM101
EXAM104
CLOS123D
ELEC.CLOS.108A
CORR.169A
CORR.170A
EXAM103
CORRIDOR173
5" 9'-11" 5" 12'-1" 9'-2"
21'-11"
9'-5"
2'-3
"3'-10
"3'-6"
EQ5
MEDS/STER/STOR
119
7654321 8a
1A6.2
3A6.3
2A6.2
3A6.2
4A6.2
5A6.2
6A6.2
1
2
3
1
2
3
4
5
6
FLOOR PLAN LEGEND
WALL
SYMBOL
TYPE FIRERATING DETAIL REMARKSWIDTH
5 1/2"1 hr
5 1/2"
7 7/8"1 hr
non-rated
non-rated
5 1/2"
7 7/8"
--
--
(E) interiorconcrete wall
TO REMAIN
(E) interior wallTO REMAIN
(n) metal studinterior wall
1 hr ratedcorridor wall
(CONVERTED FRAME)
(n) 1 hr ratedcorridor wall
DESCRIPTION
KEY NOTES:
PATCH WALLS AS NECESSARY TO MATCH(E) ADJACENT WALL TEXTURE
(E) EXTERIOR wallTO REMAIN
INSTALL 2"X2"X48" STAINLESS STEELWALL CORNER GUARD
(n) drinking fountain. see det.for requirements
(E) frame to be reglazed withlow-e dual paned glass windowto maTCh existing.
(E) recessed trash RECEPTACLE to remain
(E) lockers to be relocated bygeneral contractor to this location
F.E.
1A6.3
(E) FIRE EXTINGUISHER CABINET TO REMAIN. FIELD VERIFYIF ENCLOSURE HAS ONE HOUR RATING. IF NOT REPLACEWITH NEW ONE HOUR RATED CABINET.
ACESSIBLE CLEARANCES AT DOORS.SEE DET. FOR REQUIREMENTS
NOTE:1. CUBICLES, OFFICE FURNITURE, RECEPTION DESKS, AND LOBBY FURNITURE are TO BE PROVIDED AND INSTALLED BY OTHERS. THESE ITEMS ARE SHOWN FOR REFERENCE ONLY.
MAT
CH
LIN
ESE
E S
HEE
T A
3.2
PLANNORTH
2
2
SCALE: 1/4" = 1'-0"1 PARTIAL FLOOR PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
INTE
RIO
R E
LEVA
TIO
NS
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A3.13
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
D43 D42
1
D41EQ3 EQ2
3
EQ3
3
1
SCALE: 3/8" = 1'-0"INTERIOR ELEVATIONS
1A3.61
LEGEND TYPICAL EXAM ROOM STATION, SEET DETAIL
(E) TRASH RECEPTACLE TO REMAIN
EQUIPMENT BY OWNER, SEE EQUIPMENT SCHEDULE, SHEET
(N) built-in CABINETS, SEE FINISH NOTES 9 & 10, SHEET
(N) ADJUSTABLE SHELVING BY GENERAL CONTRACTOR
'BOB RICK' B-505 Recessed SPECIMEN PASS-THROUGH CABINET
A3.153
TYPICAL EXAM ROOM STATION, SEET DETAIL
(E) TRASH RECEPTACLE TO REMAIN
EQUIPMENT BY OWNER, SEE EQUIPMENT SCHEDULE, SHEET
(N) built-in CABINETS, SEE FINISH NOTES 9 & 10, SHEET
(N) ADJUSTABLE SHELVING BY GENERAL CONTRACTOR
'BOB RICK' B-505 Recessed SPECIMEN PASS-THROUGH CABINET
NOTE:1. CUBICLES, OFFICE FURNITURE, AND RECEPTION DESKS, are TO BE PROVIDED AND INSTALLED BY OTHERS. THESE ITEMS ARE SHOWN FOR REFERENCE ONLY.
2
01 PROVIDER BULLPEN 132 - North 02 PROVIDER BULLPEN 132 - East 03 PROVIDER BULLPEN 132 - South
04 PROVIDER BULLPEN 132 - West
01 ISOLATION 134 - North 02 ISOLATION 134 - East 03 ISOLATION 134 - South 04 ISOLATION 134 - West
01 I.Z. 138 - North 02 I.Z. 138 - East 03 I.Z. 138 - South 04 I.Z. 138 - West
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
PAR
TIA
L FL
OO
R P
LAN
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A3.2
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
SEQ1
8SE
Q10
SEQ1
4
D50 D49
D21
D44D43
D38
D37
D39
D40
D52
D54D33
D84
D36
D83
D42
D45
D51
D34D35
D41
D82
W04W03
D47
D48
D46
D53
D85
RF / E
Q3FZ
/ EQ2
F.E.
RF / EQ4
1A3.4
5A6.1
5A6.15
A6.1
10A6.1
10A6.1
36'-4" 7'-10"
20'-5"
12'-6" 8'-1"
12'-4"
5'-5"
6'-8" 6'-5" 7'-0" 12'-4"
4'-0
"
4'-8"
4'-0
"
2'-11" 4'-0" 2'-4" 13'-2" 13'-0"
8'-1"
4'-0" 3'-4" 1'-7"
EQ. EQ.
15'-8"11'-3" 3'-0"
6"
3'-5"
6'-4"
6'-1"13'-4"
12'-5" 18'-10" 2'-8"1'-7"
4" 6'-0" 7'-3"
32'-9" 11'-4"
7'-1
"4'-5"
7'-0
"
2'-3
"13
'-10
"2'-5
"
8'-0" 15'-8" 9'-7"
4'-0
"4'-0
"
9'-3"
9'-7"
19'-5" 3'-4" 11'-7"
4'-3" 13'-9" 6'-0" 6'-5" 5'-9" 8'-11" 15'-4"
5'-9"
2'-2
"
6'-0" 3'-8" 8" 3'-4" 6'-4"
3'-2"
1'-10
"
EQ EQ
4'-0
"4'-0
"
SEQ1
13'-6"
5'-5"
24'-1" 8"
4'-0
"5'-3"
9'-7"
5'-5"
7'-4
"10
'-5"
6'-3"
4'-8"
6'-0
"2'-0
"
5'-0
"
1'-0
"8'-11"
8'-10
"
5'-0"TYP.
5'-0
"
5'-0
"
5'-0"
01
02
03
04 A3.4
01
02
03
04 A3.4
01
02
03
04 A3.13
02
01
02
03
04 A3.11
01
02
03
04 A3.12
01
02
03
04 A3.12
01
02
03
04 A3.12
01
02
03
04 A3.13
01
02
03
04 A3.13
01
02
03
04 A3.15
01
02
03
04 A3.14
01
02
03
04 A3.14
01
02
03
04 A3.14
01
02
03
04 A3.16
01
02
03
04 A3.16
01
03
04 A3.17
01
02
03
04 A3.17
04
01
02
03
04 A3.22
01
02
03
04 A3.22
01
02
03
04 A3.22
01A3.14
02A3.14
2 2
1
2
1
2
2
2
22
2
4
3
1
33
2
2
1
2 2
2
2
2
2
1
2
2
3
2
2
3
3
3
7
2
2
2
2
2
2
3
3
3
2
2
2
2
(N) 42"HIGH WALL
8
9
(N) linoleum tile -COLOR 1
(N) linoleumtile -COLOR 2
11 11
1010
1010
1010
10
(N) linoleum tile -COLOR 2
(N) linoleum tile -COLOR 1
SEQ12SEQ11
SEQ4
SEQ7
SEQ5
SEQ8
SEQ3
SEQ 15
SIM.
SIM.
CORRIDOR169
OFFICE136
W.C.133
ISOLATION134
OFFICE135
CORRIDOR141
CORRIDOR168
EXAM127
EXAM128
EXAM130
EXAM129
EXAM131
WOMEN'SRESTROOM
139
MEN'SRESTROOM
140
I.Z.138
ELEVATORSN.I.C.
DRAW ROOM142A
DRAW ROOM142B
PHLEBOTOMY142
STAT LAB142C
REGISTRATION &WAITING
100
MEDS/STER/STOR
144
RECEP
TIO
N16
5
FAX142D
BUSINESSOFFICE
149
HLTH CTR MGR163
PH MED REC164
EXAM153A
IBH OFFICE153D
PROVIDERBULLPEN
132
CORRIDOR137
W.C.143
CORR166A
CORR.169A
CORR.100A
CORRIDOR174
CORRIDOR173
SEQ1
3SE
Q2
W02
W01
21'-11"
12'-9"
6'-1"
EQ
EQ
1
2
EQ6
11 151413121098a
1A6.2
3A6.3
2A6.2
3A6.2
4A6.2
5A6.2
6A6.2
1
2
3
1
2
3
4
FLOOR PLAN LEGEND
WALL
SYMBOL
TYPE FIRERATING DETAIL REMARKSWIDTH
5 1/2"1 hr
5 1/2"
7 7/8"1 hr
non-rated
non-rated
5 1/2"
7 7/8"
--
--
(E) interiorconcrete wall
TO REMAIN
(E) interior wallTO REMAIN
(n) metal studinterior wall
1 hr ratedcorridor wall
(CONVERTED FRAME)
(n) 1 hr ratedcorridor wall
DESCRIPTION
KEY NOTES:
PATCH WALLS AS NECESSARY TO MATCH(E) ADJACENT WALL TEXTURE
(E) EXTERIOR wallTO REMAIN
INSTALL 2"X2"X48" STAINLESS STEELWALL CORNER GUARD
(n) drinking fountain. see det.for requirements
(E) frame to be reglazed withlow-e dual paned glass windowto maTCh existing.
7
8
INFILL FLOOR with concrete - see structural drawings.THE TOP OF FLOOR INFILL SHOULD FLUSH OUT WITH(E) ADJACENT FLOORING.
(N) EMPLOYEE lockers BY GENERAL CONTRACTOR -'GLOBAL' INFINITY™ LOCKER, DOUBLE TIER 3 WIDE,12X18X36, ASSEMBLED GRAY
F.E.
1A6.3
9
11
10
(E) FIRE EXTINGUISHER CABINET TO REMAIN. FIELD VERIFYIF ENCLOSURE HAS ONE HOUR RATING. IF NOT REPLACEWITH NEW ONE HOUR RATED CABINET.
ACESSIBLE CLEARANCES AT DOORS.SEE DET. FOR REQUIREMENTS
NOTE:1. CUBICLES, OFFICE FURNITURE, RECEPTION DESKS, AND LOBBY FURNITURE are TO BE PROVIDED AND INSTALLED BY OTHERS. THESE ITEMS ARE SHOWN FOR REFERENCE ONLY.
APPLY WINDOW FILM ON INTERIOR SIDE OF WINDOWS -3M™ BLACKOUT FILM
GREY HATCH INDICATES AREA OF FLOOR TO RECEIVEPRIMER AND SELF-LEVELING UNDERLAYMENT COMPOUNDPRIOR TO INSTALLATION OF NEW FLOORING.
SLOPE (N) SELF-LEVELING FLOOR UNDERLAYMENTIN THESE AREAS TO PROVIDE A SMOOTH TRANSITIONBETWEEN ADJOINING FLOOR HEIGHTS.
MAT
CH
LIN
ESE
E S
HEE
T A
3.1
MAT
CH
LIN
ESE
E S
HEE
T A
3.3
PLANNORTH
22
2
2
2
2
SCALE: 1/4" = 1'-0"1 PARTIAL FLOOR PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
PAR
TIA
L FL
OO
R P
LAN
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A3.3
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
D69
D68
D87
D54 D56
D79
D65
D64
D84
E
D83
D62
D63
D61
D60
D76 D75 D74
D73D71
D70
D72
D67
D66
D51
D82 D81 D80
D59
D77
D78D57D53 D55
F.E.
1A3.5
5A6.1
5A6.1
6A6.1
5A6.1
6A6.1
5A6.1
5A6.1
10A6.1
5'-3"
10'-2"
7'-1
0"
8'-1" 13'-2" 32'-9"
18'-5"
6'-7"
9'-0
"
12'-4" 5'-2" 11'-3"
8'-1" 17'-0"
13'-3"
13'-3"
5'-2"
9'-2" 9'-7" 9'-11"
2'-3"
7'-6" 7'-6" 10'-6"
5'-10
"6'-4"
12'-6" 4'-5" 7'-10"
8'-6"
4'-0
"
5'-5" 15'-11"
8'-8"
8'-8"
13'-0" 6'-5" 14'-4" 7'-10" 8'-3"
1'-6"
4'-0" 7'-6" 4'-4"
2'-5"
8'-10
"4'-9"
4'-9"
2'-5
"2'-4
"
9'-7" 6'-6" 28'-4" 7'-2" 3'-7"
9'-3"
9'-7"
3'-4" 11'-7" 6'-0" 27'-4" 3'-2"
2'-0
"3'-0
"14
'-6"
6'-7"
15'-0
"
15'-4" 29'-8" 14'-2"
6'-9"
4'-2"
6'-10
"
2'-3" 5'-7"
7'-0
"3'-9"
7'-0
"
9'-1"
8'-8"
9'-1"
8'-8"
7"8'-5"
2'-5
"2'-4
"4'-9"
12'-2"
8'-2" 8'-3"
6'-9"
4'-2"
5'-10
"
5'-0"
8" 12'-9" 14'-5"
01
02
03
04 A3.5
01
02
03
04 A3.5
01
02
03
04 A3.16
01
02
03
04 A3.16
01
02
03
04 A3.17
01
02
03
04 A3.17
01
02
03
04 A3.17
01
02
03
04 A3.18
01
02
03
04 A3.18
01
02
03
04 A3.18
01
02
03
04 A3.17
01
02
03
04 A3.18
01
02
03
04 A3.19
01
02
03
04 A3.20
01
02
03
04 A3.20
01
02
03
04 A3.20
01
02
03
04 A3.20
01
02
03
04 A3.19
01
02
03
04 A3.19
01
02
03
04 A3.21
01
02
03
04 A3.21
01
02
03
04 A3.21
01
02
03
04 A3.22
3 3
2
2
22
44
3
2
2
2
2
3 2 2 2
3
3
3
3
3
3
32
2
1
1
3
2
2
2
2
3
3
3
3
33
3
3
2
2
1
8
SEQ7
SEQ3
CORRIDOR166
EXAM SUITE154
WOMEN'SRESTROOM
146 MEETING ROOM157
STAIR150A
STOR.152
STOR.151
N.I.C.MED DIR
148
EXAM145
EXAM154A
EXAM154B
EXAM154C
MEN'SRESTROOM
147
OFFICE156
PROVIDERBULLPEN
160HLTH CTR MGR
163EXAM
161
EXAM162
EXAM153BEXAM
153A
IBH OFFICE153D
IBH OFFICE153C
EXAM STE153
IBH SUITEN.I.C.155
IBH OFFICEN.I.C.155A
IBH OFFICEN.I.C.155B
IBH OFFICEN.I.C.155C
IBH OFFICEN.I.C.155D
IBH OFFICEN.I.C.155E
IBH OFFICEN.I.C.155F
IBH OFFICE158A
EXAM SUITE158
IBH OFFICE158B
EXAM158C
EXAM158F
EXAM158E
EXAM158D
W.C.159
CORRIDOR167
CORR166A
CORR.168A
D58
EQ6
22201918171615 21
1A6.2
3A6.3
2A6.2
3A6.2
4A6.2
5A6.2
6A6.2
1
2
3
1
2
3
4
FLOOR PLAN LEGEND
WALL
SYMBOL
TYPE FIRERATING DETAIL REMARKSWIDTH
5 1/2"1 hr
5 1/2"
7 7/8"1 hr
non-rated
non-rated
5 1/2"
7 7/8"
--
--
(E) interiorconcrete wall
TO REMAIN
(E) interior wallTO REMAIN
(n) metal studinterior wall
1 hr ratedcorridor wall
(CONVERTED FRAME)
(n) 1 hr ratedcorridor wall
DESCRIPTION
KEY NOTES:
PATCH WALLS AS NECESSARY TO MATCH(E) ADJACENT WALL TEXTURE
(E) EXTERIOR wallTO REMAIN
INSTALL 2"X2"X48" STAINLESS STEELWALL CORNER GUARD
(n) drinking fountain. see det.for requirements
(E) frame to be reglazed withlow-e dual paned glass windowto maTCh existing.
8(N) EMPLOYEE lockers BY GENERAL CONTRACTOR -'GLOBAL' INFINITY™ LOCKER, DOUBLE TIER 3 WIDE,12X18X36, ASSEMBLED GRAY
F.E.
1A6.3
(E) FIRE EXTINGUISHER CABINET TO REMAIN. FIELD VERIFYIF ENCLOSURE HAS ONE HOUR RATING. IF NOT REPLACEWITH NEW ONE HOUR RATED CABINET.
ACESSIBLE CLEARANCES AT DOORS.SEE DET. FOR REQUIREMENTS
NOTE:1. CUBICLES, OFFICE FURNITURE, RECEPTION DESKS, AND LOBBY FURNITURE are TO BE PROVIDED AND INSTALLED BY OTHERS. THESE ITEMS ARE SHOWN FOR REFERENCE ONLY.
MAT
CH
LIN
ESE
E S
HEE
T A
3.2
PLANNORTH
22
SCALE: 1/4" = 1'-0"1 PARTIAL FLOOR PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
EN
LAR
GE
D P
LAN
S /
INTE
RIO
R E
LEVA
TIO
NS
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A3.4
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
D34D35
60"
MIN
.
24" MIN.
60"
MIN
.
24" MIN.
60" M
IN. 60" MIN.
34" MIN. 34" MIN.
59" MIN. FOR FLR. MTD. W.C.59" MIN. FOR FLR. MTD. W.C.
01
02
03
04 A3.4
01
02
03
04 A3.4
4
3
22
1
33
5
6
66
37
7
1
9
10 10
9
4
5
8
6
11 11
8
1212
30"X48"CLR SPACE
30"X48"CLR SPACE
WOMEN'SRESTROOM
139
MEN'SRESTROOM
140
1
14
5
4
8
12
34" A
.F.F.
MA
X.
27"
MIN
.
2
5
8
46
12
14
3
15
77
D34
3
14
1
15
14
8
1
14
5
4 14
1
15
1414
34" A
.F.F.
MA
X.
27"
MIN
.
5
4
8
6
3
3
2
14
12
15
6
D35
19"
MIN
.
48"
MO
UN
TIN
G H
IEG
HT
FOR
RES
TRO
OM
AC
CES
SOR
IES
WIT
H O
PER
ABL
E PA
RTS
40"
MA
X.
33'-3
6"
MIRRORTOWEL /WASTE
SOAPDISPENSERSEAT COVER
GRAB BAR
TISSUE
8A6.3
8A6.3
8A6.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BATHROOM FIXTURE / ACCESSORY LEGEND 'BOBRICK' B-3852 ClassicSeries® Semi-Recessed Convertible Paper Towel Dispenser and Waste Receptacle
'BOBRICK' B-6806 1 1/2" Dia. Stainless Steel Grab Bars w/ Snap Flange
'BOBRICK' B-2888 Surface-Mounted Multi-Roll Toilet Tissue Dispenser
'BOBRICK' 818615 ConturaSeries® Surface-Mounted Soap Dispenser for Antibacterial Soaps
'BOBRICK' B-293 Tilt Mirror w/ Stainless Steel Frame
'BOBRICK' B-221 ClassicSeries® Surface-Mounted Seat-Cover Dispenser
'BOBRICK' B-270 ConturaSeries® SURFACE-MOUNTED Sanitary Napkin Disposal
'truebro' lavguard®2 e-z series - Under lavatory pipe guard
Sanitary facility Door Signage - SEE
Sanitary facility Wall Signage - SEE
3M™ BLACKOUT FILM
EPOXY RESIN COUNTERTOP - DURCON INC, GRAPHITE
NOT USED
48" MARMOLEUM WAINSCOT WITH aluminum CAP, TYP. ALL WALLS - MARMOLEUM WALTON UNI, 186, LEAD
TOILET PARTITION - 'BOBRICK' SIERRA™ Series, SC01, GOLDEN KHAKI
2A3.4
4A6.3
5A6.3
7A6.3
NOTE:
1. SEE FOR ACCESSIBLE ACCESSORY MOUNTING HEIGHTS
2. Toilet compartment door shall have automatic closing device and clear opening of 34" min.
3. Hardware shall be equipped with a loop or U-shaped handle below the latch.
4. 6" min. wall base typ.
5. Toilet to be 17" high Min. and 19" Max. including toilet seat.
6. Wall Hung Sink to be Mounted with Rim 34" AFF Max.
7. see details for further information on accessibility requirements.
2
2
2
2
SCALE: 3/8" = 1'-0"1 RESTROOMS 139 & 140 - Enlarged Plan and Interior Elevations
01 RESTROOM 139 - North 02 WOMEN'S RESTROOM 139 - East 03 WOMEN'S RESTROOM 139 - South
04 WOMEN'S RESTROOM 139 - West
01 MEN'S RESTROOM140 - North 02 MEN'S RESTROOM140 - East 03 MEN'S RESTROOM140 - South
04 MEN'S RESTROOM140 - West
SCALE: 1/2" = 1'-0"2 RESTROOM ACCESSORY MOUNTING HEIGHTS
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
RE
FLE
CTE
D C
EIL
ING
PLA
N
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A4.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
11 22201918171615141312109765432
H
G
E
D
B
A
1
E1
C1
8a 21
PLANNORTH
C
C
1S1
8'-0" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F. 8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F. 8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F. 8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
(E) to remain
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F.
8'-o" A.F.F.
8'-9 1/2" A.F.F. 8'-o" A.F.F.
8'-9 1/2" A.F.F.8'-9 1/2" A.F.F.8'-9 1/2" A.F.F.8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F.
VARIES
8'-0" A.F.F.
8'-0" A.F.F. 8'-9 1/2" A.F.F.
8'-0" A.F.F.
8'-0" A.F.F.8'-0" A.F.F.8'-0" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-0" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
1
8'-9 1/2" A.F.F.
8'-9 1/2" A.F.F.
8'-0" A.F.F.
1
exit
N.I.C.
N.I.C.
N.I.C. N.I.C.
N.I.C.N.I.C.
N.I.C.N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C. N.I.C.
1A6.1
2A6.1
6S2
1
CEILING SYMBOLSRECESSED FIXTURE PERELECTRICAL DRAWINGS
2'X4' GRID MOUNTED LIGHT FIXTUREPER ELECTRICAL DRAWINGS
2'X2' GRID MOUNTED LIGHT FIXTUREPER ELECTRICAL DRAWINGS
(N) SUSPENDEDACOUSTICAL CEILING TILE. SEE DETS.
(N) GTYPSUM WALLBOARD CEILING SUPPORTEDBY steel JOISTS @ 16" o.c. - see structural det.
NOTES:
EXISTING SOFFIT TO REMAIN. ALL EXPOSED SURFACES TO RECEIVE NEW PAINT.
4'w x 2"L x 5"D wall MOUNTED LIGHT FIXTUREPER ELECTRICAL DRAWINGS
24" DIA PENDANT MOUNTED LIGHT FIXTUREPER ELECTRICAL DRAWINGS
SUPPLY
RETURN
EXHAUST
2
2
SCALE: 3/32" = 1'-0"1 REFLECTED CEILING PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
DO
OR
/ W
IND
OW
SC
HE
DU
LES
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A5.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
DOOR SCHEDULE
MARKSIZE
W HTMATL FRAME GLZ TYPE
DETAIL
JAMB HEAD SILLFIRE
RATINGHDWRGROUP NOTES
3'-0"
6'-8
"
34"
MIN
44"
MA
X.
3'-0"
6'-8
"
34"
MIN
44"
MA
X.
4"
25"
3'-6"
6'-8
"
25"
4"
34"
MIN
44"
MA
X.
6'-0"
6'-8
"
25"
4"
3'-6"
6'-8
"
34"
MIN
44"
MA
X.
A B C D E
DOOR NOTES1. DOORS WITHOUT A MARKER ARE EXISTING TO REMAIN
2. SEE FLOOR PLAN FOR DOOR SWING DIRECTION
3. SEE DOOR HARDWARE SPECIFICATION FOR DETAILS OF HARDWARE GROUPS
4. CONTRACTOR TO VERIFY JAMB WIDTH PRIOR TO ORDERING DOOR FRAMES
5'-0"
6'-8
"
2'-8"
6'-8
"
34"
MIN
44"
MA
X.
2'-2"
6'-8
"
34"
MIN
44"
MA
X.
6'-0"
6'-8
"
E F G J K
WINDOW SCHEDULE
MARK
W01
W02
W03
W04
ELEVATION
10A6.1
10A6.1
10A6.1
DIM (W x H)
4'-0"x3'-4"
3'-0"x3'-4"
3'-0"x3'-4"
3'-0"x3'-4"
FIRERATING
45 min.
45 min.
45 min.
45 min.
MATL
STEEL/WIREGLASS
STEEL/WIREGLASS
STEEL/WIREGLASS
STEEL/WIREGLASS
OPERATION
SLIDING
FIXED
SLIDING
SLIDING
HDR HT
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
FYRE-TEC 900 SERIES ORAPPROVED EQUAL. FRAMECOLOR TO BE CHOSEN BYARCHITECT. PROVIDE LOCK.
FYRE-TEC 900 SERIES ORAPPROVED EQUAL. FRAMECOLOR TO BE CHOSEN BYARCHITECT.
FYRE-TEC 900 SERIES ORAPPROVED EQUAL. FRAMECOLOR TO BE CHOSEN BYARCHITECT. PROVIDE LOCK.
FYRE-TEC 900 SERIES ORAPPROVED EQUAL. FRAMECOLOR TO BE CHOSEN BYARCHITECT. PROVIDE LOCK.
D72
D73
D74
D75
D76
D77
D78
D79
D80
D81
D82
D83
D84
D85
D86
D87
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
5'-0"
2'-8"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-6"
3'-0"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
(E) DOOR
(E) DOOR
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
(E) FRAME
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
--
--
--
--
--
--
--
--
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
A
A
A
A
A
F
G
A
A
A
A
A
A
B
--
--
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
--
3/A6.1
3/A6.1
3/A6.1
3/A6.1
3/A6.1
--
--
--
3/A6.1
3/A6.1
--
--
--
--
--
(non-rated)
(non-rated)
(non-rated)
(non-rated)
(non-rated)
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
(non-rated)
(non-rated)
20 min.
--
20 min.
11
10
10
10
10
19
14
6
1
1
6
11
11
6
20
--
--
--
--
--
--
--
--
--
--
--
--
--
UNDERCUT DOOR 3/4"
VISION PANEL
(N) SECURITY HARDWARE. INTERIOR SIDEOF DOOR/FRAME TO BE REPAINTED.(E) DOOR TO REMAIN. REPLACE (E) DOORFRAME W/ (N) 20 MIN. RATED H.M. FRAME.
DOOR SCHEDULE
MARK
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
D11
D12
D13
D14
D15
D16
D17
D18
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
D51
D52
D53
D54
D55
D56
D57
D58
D59
D60
D61
D62
D63
D64
D65
D66
D67
D68
D69
D70
D71
SIZE
W
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-6"
6'-0"
3'-0"
3'-0"
3'-0"
3'-0"
2'-2"
2'-8"
3'-0"
3'-0"
3'-0"
3'-0"
2'-2"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-6"
2'-8"
3'-0"
3'-0"
6'-0"
6'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
MATL
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
SOLID CORE WOOD.DOUG FIR VENEER.
FRAME
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.20 MIN. RATED.
PAINTED HOLLOW METAL FRAME.
GLZ
--
--
--
--
--
--
--
--
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
--
--
--
--
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
--
--
--
--
FIRE RATED GLAZING, 100SQ. IN. MAX.
--
TYPE
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
A
A
A
E
K
B
A
A
A
J
G
A
A
A
A
J
A
A
A
B
A
A
A
A
A
A
A
B
B
B
C
G
A
A
D
D
A
A
A
A
A
A
B
A
A
A
A
B
A
A
A
A
A
B
A
DETAIL
JAMB
--
--
HEAD
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
4/A6.1
SILL
3/A6.1
3/A6.1
3/A6.1
3/A6.1
--
--
3/A6.1
3/A6.1
3/A6.1
3/A6.1
--
3/A6.1
3/A6.1
--
--
--
3/A6.1
3/A6.1
--
--
--
3/A6.1
3/A6.1
3/A6.1
--
--
--
--
--
--
--
3/A6.1
--
--
--
3/A6.1
3/A6.1
3/A6.1
3/A6.1
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
3/A6.1
--
--
--
3/A6.1
3/A6.1
3/A6.1
3/A6.1
--
3/A6.1
3/A6.1
3/A6.1
--
--
--
3/A6.1
FIRERATING
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
(non-rated)
20 min.
(non-rated)
(non-rated)
(non-rated)
(non-rated)
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
(non-rated)
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
(non-rated)
20 min.
(non-rated)
(non-rated)
20 min.
20 min.
(non-rated)
(non-rated)
(non-rated)
(non-rated)
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
20 min.
(non-rated)
(non-rated)
(non-rated)
(non-rated)
20 min.
(non-rated)
(non-rated)
(non-rated)
20 min.
20 min.
20 min.
(non-rated)
HDWRGROUP
1
1
1
1
2
3
1
1
1
4
5
1
1
6
6
6
4
4
7
8
9
10
11
10
12
5
13
13
13
6
14
1
15
15
13
1
1
1
1
13
6
6
13
13
9
16
5
17
17
18
18
6
13
6
1
15
15
9
10
11
11
10
9
10
10
10
6
6
9
11
NOTES
--
--
--
--
--
--
--
--
--
--
--
--
--
VISION PANEL
--
--
--
--
--
HOLD OPEN / CARD READER
VISION PANEL / HOLD OPEN
--
--
--
--
CARD READER
CARD READER
CARD READER
--
--
--
--
--
VISION PANEL / CARD READER
--
--
--
--
CARD READER
--
--
VISION PANEL / CARD READER
VISION PANEL / CARD READER
VISION PANEL / HOLD OPEN
VISION PANEL / CARD READER
--
--
--
VISION PANEL / CARD READER
VISION PANEL / CARD READER
--
CARD READER
--
--
--
--
VISION PANEL / HOLD OPEN
--
--
--
--
VISION PANEL / HOLD OPEN
--
--
--
--
--
VISION PANEL / HOLD OPEN
--
2
2
DOOR TYPES
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
RO
OM
FIN
ISH
SC
HE
DU
LE
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
A5.2
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
154
154A
154B
154C
155
155A
155B
155C
155D
155E
155F
156
157
158
158A
158B
158C
158D
158E
158F
159
160
161
162
163
164
165
166
166A
167
168
168A
169
169A
170
170A
171
171A
172
173
174
EXAM SUITE
EXAM
EXAM
EXAM
IBH SUITE
IBH OFFICE
IBH OFFICE
IBH OFFICE
IBH OFFICE
IBH OFFICE
IBH OFFICE
OFFICE
MEETING ROOM
EXAM SUITE
IBH OFFICE
IBH OFFICE
EXAM
EXAM
EXAM
EXAM
W.C.
PROVIDER BULLPEN
EXAM
EXAM
HLTH CTR MGR
PH MED REC
RECEPTION
CORRIDOR
CORR
CORRIDOR
CORRIDOR
CORR.
CORRIDOR
CORR.
CORRIDOR
CORR.
CORR.
STOR.
CORRIDOR
CORRIDOR
CORRIDOR
ACT
ACT
ACT
ACT
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-0"
8'-9 1/2"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
(E) TO REMAIN
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
-FINISH SCHEDULE
ROOM NUMBER ROOM NAME CEILING CLG. HGHT FLOORING BASEBOARD WALLS NOTES
FINISH NOTES:
1. LINOLEUM TILE COLOR 1 - MARMOLEUM MODULAR, T3053, DOVE BLUE, 20"X20" - EACH TILE TO BE PLACED AT A QUARTER TURN TO ITS ADJACENT TILE
2. LINOLEUM TILE COLOR 2 - MARMOLEUM MODULAR, T3136, CONCRETE, 20"X20" - EACH TILE TO BE PLACED AT A QUARTER TURN TO ITS ADJACENT TILE
3. LINOLEUM SHEET COLOR 1 - MARMOLEUM REAL, 3053, DOVE BLUE
4. LINOLEUM SHEET COLOR 3 - MARMOLEUM REAL, 3233, SHITAKE
5. LINOLEUM SHEET COLOR 4 - MARMOLEUM WALTON UNI, 186, LEAD
6. RUBBER - 4" BURKE FLOORING, UNI-COLOR, 208 LIGHT GRAY
7. COVED 6" - MARMOLEUM REAL, 3233, SHITAKE
8. PAINT - KELLY MOORE, KMW46-1, PICKET FENCE
9. ALL PLASTIC LAMINATE CABINET BODIES, DOORS, AND EXPOSED FACES TO BE WILSONART, 1572-60, ANTIQUE WHITE
10.ALL PLASTIC LAMINATE COUNTERTOPS TO BE WILSONART, D96-60, SHADOW
11.ALL EPOXY RESIN COUNTERTOPS TO BE DURCON INC, GRAPHITE
12.WINDOW FILM 1 - 3M™ BLACKOUT FILM
13.TOILET PARTITIONS - 'BOBRICK' SIERRA™ SERIES, SC01, GOLDEN KHAKI
14.(NOT USED)
15.ACT - ARMSTRONG, OPTIMA HEALTH ZONE, PRODUCT NO. 3125, 24" X 48", WHITE / TEGULAR IN NEW ARMSTRONG PRELUDE 15/16" EXPOSED TEE SYSTEM
-FINISH SCHEDULE
ROOM NUMBER
100
100A
101
102
103
104
105
106
107
108
108A
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
123A
123B
123C
123D
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
142A
142B
142C
142D
143
144
145
146
147
148
149
150A
150B
151
152
153
153A
153B
153C
153D
ROOM NAME
(E) SHAFT
(E) SHAFT
ELEVATORS
REGISTRATION & WAITING
CORR.
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
ORTHO
CLOS.
ELEC. CLOS.
EXAM
IBH OFFICE
W.C.
EXAM
EXAM
IBH OFFICE
NURSING SUPR
RAD. OFFICE
IBH OFFICE
BREAK ROOM
MEDS/STER/STOR
XRAY
W.C.
CHANGING RM
EXAM SUITE
EXAM
IBH OFFICE
EXAM
CLOS
W.C.
COMP.
PROVIDER BULLPEN
EXAM
EXAM
EXAM
EXAM
EXAM
PROVIDER BULLPEN
W.C.
ISOLATION
OFFICE
OFFICE
CORRIDOR
I.Z.
WOMEN'S RESTROOM
MEN'S RESTROOM
CORRIDOR
PHLEBOTOMY
DRAW ROOM
DRAW ROOM
STAT LAB
FAX
W.C.
MEDS/STER/STOR
EXAM
WOMEN'S RESTROOM
MEN'S RESTROOM
MED DIR
BUSINESS OFFICE
STAIR
STAIR
STOR.
STOR.
EXAM STE
EXAM
EXAM
IBH OFFICE
IBH OFFICE
CEILING
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS(N) HARD LID /SEMIGLOSS
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
ACT
(N) HARD LID /SEMIGLOSS
ACT
ACT
(N) HARD LID /SEMIGLOSS(N) HARD LID /SEMIGLOSS
ACT
ACT
(E) TO REMAIN
(E) TO REMAIN
(N) HARD LID /SEMIGLOSS(N) HARD LID /SEMIGLOSS
ACT
ACT
ACT
ACT
ACT
CLG. HGHT
0'-0"
0'-0"
0'-0"
11'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-9 1/2"
8'-0"
8'-0"
8'-9 1/2"
8'-0"
8'-0"
9'-0"
8'-0"
8'-0"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-0"
8'-0"
8'-9 1/2"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-0"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
0'-0"
0'-0"
8'-0"
8'-0"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
8'-9 1/2"
FLOORING
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
LINOLEUM TILE - COLOR 1 &COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
(E) TO REMAIN
(E) TO REMAIN
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 1
(E) TO REMAIN
LINOLEUM SHEET - COLOR 1
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
LINOLEUM TILE - COLOR 2
LINOLEUM SHEET - COLOR 3
LINOLEUM SHEET - COLOR 3
LINOLEUM TILE - COLOR 2
LINOLEUM SHEET - COLOR 1
LINOLEUM SHEET - COLOR 1
LINOLEUM SHEET - COLOR 1
LINOLEUM SHEET - COLOR 1
LINOLEUM SHEET - COLOR 1
(E) TO REMAIN
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
LINOLEUM SHEET - COLOR 3
LINOLEUM SHEET - COLOR 3
LINOLEUM TILE - COLOR 2
LINOLEUM TILE - COLOR 2
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
LINOLEUM TILE - COLOR 1
BASEBOARD
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
(E) TO REMAIN
RUBBER
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
RUBBER
COVED 6"
COVED 6"
RUBBER
COVED LINOLEUM /SEE DET. 7/A6.1COVED LINOLEUM /SEE DET. 7/A6.1COVED LINOLEUM /SEE DET. 7/A6.1COVED LINOLEUM /SEE DET. 7/A6.1COVED LINOLEUM /SEE DET. 7/A6.1
(E) TO REMAIN
RUBBER
RUBBER
COVED 6"
COVED 6"
RUBBER
RUBBER
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
RUBBER
RUBBER
RUBBER
RUBBER
RUBBER
WALLS
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - SEMIGLOSS / LINOLEUM TO 48"
PAINT - SEMIGLOSS / LINOLEUM TO 48"
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EPOXY
PAINT - EGGSHELL
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - SEMIGLOSS / LINOLEUM TO 48"
PAINT - SEMIGLOSS / LINOLEUM TO 48"
PAINT - EGGSHELL
PAINT - EGGSHELL
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
(E) TO REMAIN
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
PAINT - EGGSHELL
NOTES
ALL WALLS, CEILINGS, AND SOFFITS TO BE REPAINTED. (E) FLOOR TORECEIVE PRIMER AND SELF-LEVELING COMPOUND UNDERLAYMENT.
PLASTIC LAMINATE ON CABINETRY / COUNTER
PLASTIC LAMINATE ON CABINETRY / COUNTER
PATCH AND PAINT ONLY THE WALL BEING CUT BACK. PATCHFLOORING AND CEILING TO MATCH (E).
LINOLEUM SHEET COLOR 4 TO 48" WITH ALUM. TOP CAP ON ALLWALLS. FILM 1 ON ALL WINDOWS.LINOLEUM SHEET COLOR 4 TO 48" WITH ALUM. TOP CAP ON ALLWALLS. FILM 1 ON ALL WINDOWS.
PLASTIC LAMINATE ON CABINETRY / EPOXY RESIN COUNTER
PLASTIC LAMINATE ON CABINETRY / EPOXY RESIN COUNTER
PLASTIC LAMINATE ON CABINETRY / EPOXY RESIN COUNTER
PLASTIC LAMINATE ON CABINETRY / EPOXY RESIN COUNTERS
PLASTIC LAMINATE ON CABINETRY / COUNTER
LINOLEUM SHEET COLOR 4 TO 48" WITH ALUM. TOP CAP ON ALLWALLS.LINOLEUM SHEET COLOR 4 TO 48" WITH ALUM. TOP CAP ON ALLWALLS.
2
2
2
2
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
A6.17/6/17Plotted On:
7/6/17AS NOTED
AR
CH
ITE
CTU
RA
L D
ETA
ILS
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/W
eath
erto
p/D
ropb
ox/1
080
Em
elin
e R
emod
el/A
rchi
cad/
1080
Em
elin
e Fi
rst F
loor
Det
ails
.pln
AR
CH
ICA
D M
AS
TER
TEM
PLA
TE [T
M] B
Y B
OB
RO
W C
ON
SU
LTIN
G G
RO
UP
| A
LL R
IGH
TS R
ES
ER
VE
D |
ww
w.b
obro
w.c
om |
ww
w.a
rchi
cadt
empl
ate.
com
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
MR
MR2 - #12 SCREWS
@ STUD TO T-BARCONNECTIONS, TYP.
T-BAR SUSPENDED CEILING GRIDWITH #12 GA. HANGER WIRES @ 48" O.C.BOTH WAYS AND STARTER HANGERWIRES MAXIMUM 8" FROM WALLS
METAL STUD COMPRESSION STRUTS @ 12'-0" O.C. MAX.EACH WAY (SEE SCHEDULE BELOW FOR SIZES) ATTACH TOPURLINS ABOVE WITH 2 - #18 SHEET METAL SCREWS -DO NOT ATTACH TO 2X SUB-PURLINS
4 - # 12 GA. SEISMIC SPLAY WIRES 45 DEGREESFROM HORIZONTAL 4 OPPOSITE DIRECTIONS@ 12'-0" O.C. EACH WAY @ COMPRESSION STRUTSATTACHED TO PURLINS W/ 16d RING SHANK NAILS
NOTES:1. VERIFY MAXIMUM ALLOWABLE HEIGHT WITH STUD MANUFACTURER2. FOR DOUBLE STUD STRUT ATTACH WEB TO FLANGE WITH #6 SCREWS @ 16" O.C.3. SC METAL STUDS HAVE 1-3/8" FLANGES XC METAL STUDS HAVE 1-5/8" FLANGES
COMPRESSION STRUT SCHEDULE
METAL STUD SIZE MAXIMUM HEIGHT OF STUD
SINGLE STUD DOUBLE STUD
1-5/8" SC 20 GA. 6'-8" 11'-8"
2-1/2" SC 20 GA. 7'-4" 16'-6"
3-5/8" SC 20 GA. 10'-0" 22'-9"
1-5/8" IX 20 GA. 7'-7" 11'-9"
FIXTURES WEIGHING MORE THAN 20 LB. SHALL BE SUSPENDEDWITH 12 GA. SUPPORT WIRES @ EACH CORNER WITH A MINIMUMOF FOUR FULL WRAPS EACH. FIXTURE SUPPORT WIRES SHALL
BE SUPPLIED AND INSTALLED BY SUSPENDED CEILINGCONTRACTOR. MAXIMUM WEIGHT OF FIXTURES SHALL BE 55 LB.
12 GA. LATERAL SUPPORT WIRES WITHIN 3"OF EACH CORNER OF LIGHT FIXTURE.
WIRES SHALL BE SPLAYED AT 45 DEGREESAND ATTACHED TO FACE OF ROOF BEAMS
OR PURLINS WITH 16d RING SHANK NAILS.MINIMUM OF FOUR TURNS AT EACH CONNECTION POINT.
CONFORM TO ALL REQUIREMENTS OF U.B.C. CHAPTER 35.
(N) HOLLOW METALDOOR FRAME -
PAINTED
(N) DOOR PERSCHEDULE
(N) pro x header bydietrich OR APPROVEDEQUAL
WALL CONSTRUCTION PERFLOORPLAN AND WALLDETAILS
existing concrete slab.verify in field
existing ASBESTOS tile flooring.do not disturb
(N) DOOR PERSCHEDULE
(n) door jamb beyond
(n) PEMKO THRESHOLD SETIN A BED OF MASTIC,PEMKO 270A
(n) PEMKO AUTOMATIC DOORBOTTOM, 411APKL
(n) FLOORING PER FINISHSCHEDULE
270_
4" MIN TO 4 15/16" MAX OPENING
OPTIONAL SERIES 911
FINAL FORMS I
TAPE & FLOAT
(BY OTHERS)
FIELD
FASTENER, TYP
(BY OTHERS)
GPDW
TYP
METAL
STUD
WINDOW
MULLION
GASKET WITH
ADHESIVE
ON BOTH SIDES
SPRING
2" 2 3/16"
PARTITION
TITLE
MULLION MATE 4
SECTION DETAIL
OPTIONAL SERIES 911
FINAL FORMS I
TAPE & FLOAT
(BY OTHERS)
FIELD FASTENER, TYP
(BY OTHERS)
GPDW
TYP
METAL
STUD
WHEN MULLION MATE IS INSTALLED
DIRECTLY AGAINST GLASS ADDITIONAL
GASKET AND/OR FIELD APPLICATION
OF ADHESIVE MAY BE REQUIRED
GASKET WITH
ADHESIVE
ON BOTH SIDES
SPRING
*3/8" THICK GLASS
SHOWN
*MULLION MATE CAN BE INSTALLED AGAINST 1/8" THICK GLASS.
INSTALL THE GASKET AGAINST THE GLASS SIDE FIRST.
BEING CAREFUL TO ONLY LET THE GASKET COME IN CONTACT
WITH THE GLASS DURING INSTALLATION.
PARTITION
TITLE
MULLION MATE
SECTION DETAIL INSTALLED
AGAINST WINDOW GLAZING
6"
AFF
INTERIOR OREXTERIOR WALL
(E) CONCRETE SLABdo not disturb (e) asbestostile if present
forbo ALUMINUM cove AND capcolor match floor. FIX TO WALLWITH per mfg specificationsBY FORBO, OR EQUAL.
welded seams withmarmoweld MC by forbocolor match to floor
ACC06 FORBO COVESTICK. TO BE GLUED
TO WALL3.5 MM MARMOLEUM
6"
AFF 48"
AFF, TYP
. A
T R
ESTR
OOM
S
INTERIOR OREXTERIOR WALL
(E) CONCRETE SLABdo not disturb (e) asbestostile if present
forbo ALUMINUM cove & capcolor match floor.FIX TO WALL per forbo instructionsor EQUAL.
welded seams withmarmoweld MC by forbocolor match to floor
ACC06 FORBOCOVE STICK
TO BE GLUED TO WALL
LINOLEUM WAINSCOT 48" high.FIX TO WALLWITH l910 AdvesiveBY FORBO, OR EQUAL.
3.5 MM MARMOLEUM
4 3
/4"
1"4 3
/4"
10 1/2
"
1 7/8"
1" THICK EPOXY RESIN SPLASHBACKTO MATCH LAB resin COUNTER
WIREMOLD 4000 SERIESRACEWAY (PLASTIC). SEEELECTRICAL SPEC.
WALL BEHIND
CABINET BELOW
(e) rated doorto remain
(e) concrete shaftwall to remain
(e) rated doorframe to remain(e) metal stud wallto remain
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(e) gyp. bd. to remain
(n) fry reglet z reveal,drmz-625-50 at jambs and head, typ.
CORRIDOR SIDE
STAIRWELL SIDE
2
NOT TO SCALE1 COMPRESSION STRUT ISOMETRIC / SCHEDULE
NOT TO SCALE2 LIGHT FIXTURE SUSPENSION DETAIL
SCALE: 3" = 1'-0"4 DOOR HEAD DETAIL
SCALE: 3" = 1'-0"3 DOOR THRESHOLD DETAIL
NOT TO SCALE5 WALL CLOSURE AT MULLION
NOT TO SCALE6 WALL CLOSURE AT GLAZING
SCALE: 3" = 1'-0"7 COVING DETAIL
SCALE: 3" = 1'-0"8 WAINSCOT DETAIL AT RESTROOMS
SCALE: 3" = 1'-0"9 LAB COUNTER BACKSPLASH DETAIL
NOT TO SCALE10 FIRE RATED WINDOW DETAILSCALE: 3" = 1'-0"10 DOOR JAMB AT EXISTING FRAME
(N) FIRE-RATED WINDOWPER WINDOW SCHEDULE
RETURN GYP. BD. ATHEAD AND JAMBS, TYP.
(N) P.LAM. FINISHEDCOUNTER
(N) HEAD CHANNEL
(N) INTERIOR SILLANGLE
(N) 3M FIRE BARRIER SEALANTFD 150 AT ALL EDGES OF WINDOWFRAME, ROOM AND CORRIDOR SIDE, TYP.
WALL CLOSURE IS MULLION MATE 4 BY GORDON INTERIOR SPECIALTIESDIVISION OR APPROVED EQUAL. FINISH TO MATCH EXISTING ADJACENTSTOREFRONT SYSTEM. CONTRACTOR TO VERIFY GAP WIDTH IN FIELDAND CONFIRM MODEL NUMBER PRIOR TO ORDERING.
WALL CLOSURE IS MULLION MATE 4 BY GORDON INTERIOR SPECIALTIESDIVISION OR APPROVED EQUAL. FINISH TO MATCH EXISTING ADJACENTSTOREFRONT SYSTEM. CONTRACTOR TO VERIFY GAP WIDTH IN FIELDAND CONFIRM MODEL NUMBER PRIOR TO ORDERING.
CORRIDOR SIDE
ROOM SIDE
6"3"
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
A6.26/30/17Plotted On:
6/30/17AS NOTED
AR
CH
ITE
CTU
RA
L D
ETA
ILS
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/W
eath
erto
p/D
ropb
ox/1
080
Em
elin
e R
emod
el/A
rchi
cad/
1080
Em
elin
e Fi
rst F
loor
Det
ails
.pln
AR
CH
ICA
D M
AS
TER
TEM
PLA
TE [T
M] B
Y B
OB
RO
W C
ON
SU
LTIN
G G
RO
UP
| A
LL R
IGH
TS R
ES
ER
VE
D |
ww
w.b
obro
w.c
om |
ww
w.a
rchi
cadt
empl
ate.
com
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
MR
MR
existing concrete slab.verify in field
existing asbestos tile flooring.do not disturb
(n) flooring per finish schedule
(n) base per finish schedule
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(n) 4" rubber base
(n) flooring per finishschedule
(n) 3-5/8" steel studs @ 16" o.c(5 1/2" at plumbing walls).
(n) 20 ga. steel bottom track.fasten to concrete with powderactuated fasteners. use hiltibrand x-dni 0.145" dia. x 2 1/2"fasteners at 24" o.c., staggeredside by side
CORRIDOR SIDE(one hour rating)
ROOM SIDE
29"
V.I.F.
6"
existing concrete slab.verify in field
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(n) 3-5/8" steel studs @ 16" o.c.(5 1/2" at plumbing walls)
fasten top track to concretewith powder actuated fasteners.use hilti brand x-dni 0.145" dia. x 2 1/2"fasteners at 24" o.c., staggeredside by side
(n) continuous 20 ga. dt sectiontrack with slotted holes in
flanges at each stud
two #12 sheet metalscrews at each stud
starter hanger wire
(n) acoustical ceiling tile
(n) t-bar suspended ceilinggrid with 12 ga. hanger wires@ 48" o.c. both ways andstarter hanger wires a max. of8" from walls
(n) acoustical ceiling tile
3m fire barrier sealantfd 150 to fill 1/4" gapat top of wall
CORRIDOR SIDE(one hour rating)
ROOM SIDE
existing concrete slab.verify in field
existing asbestos tile flooring.do not disturb
(n) flooring per finish schedule
(n) base per finish schedule
(e) 5/8" gypsum wallboard
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(e) 3-5/8" steel studs
(e) bottom track
(e) 5/8" gypsum wallboard
(n) 4" rubber base
(n) flooring per finishschedule
CORRIDOR SIDE(one hour rating)
ROOM SIDE
29"
V.I.F.
existing concrete slab.verify in field
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(E) TOP TRACK
starter hanger wire
(n) acoustical ceiling tile
(n) t-bar suspended ceilinggrid with 12 ga. hanger wires@ 48" o.c. both ways andstarter hanger wires a max. of8" from walls(e) 3-5/8" steel studs @ 16" o.c.
(n) acoustical ceiling tile
(e) gypsum wallboard
(E) GYP. BOARD STOPS 3"-6" ABOVE(e) ACT CEILING
3m fire barrier sealantfd 150 to fill 1/4" gapat top of wall
CORRIDOR SIDE(one hour rating)
ROOM SIDE
existing concrete slab.verify in field
existing asbestos tile flooring.do not disturb
(n) flooring per finish schedule
(n) base per finish schedule
(n) 5/8" type x gypsum boardvertically applied with 1" types screws 8" o.c. at perimeterand 12" o.c. in the field. jointsstaggered on opposite side.
(n) 4" rubber base
(n) flooring per finishschedule
(n) 3-5/8" steel studs @ 16" o.c(5 1/2" at plumbing walls).
(n) 20 ga. steel bottom track.fasten to concrete with powderactuated fasteners. use hiltibrand x-dni 0.145" dia. x 2 1/2"fasteners at 24" o.c., staggeredside by side
ROOM SIDE
ROOM SIDE
29"
V.I.F.
6"
existing concrete slab.verify in field
(n) 3-5/8" steel studs @ 16" o.c.(5 1/2" at plumbing walls)
fasten top track to concretewith powder actuated fasteners.use hilti brand x-dni 0.145" dia. x 2 1/2"fasteners at 24" o.c., staggeredside by side
(n) continuous 20 ga. dt sectiontrack with slotted holes in
flanges at each stud
two #12 sheet metalscrews at each stud
starter hanger wire
(n) acoustical ceiling tile
(n) t-bar suspended ceilinggrid with 12 ga. hanger wires@ 48" o.c. both ways andstarter hanger wires a max. of8" from walls
(n) acoustical ceiling tile
(n) 5/8" type x gypsumwallboard
ROOM SIDE
ROOM SIDE
Design No. V497BXUV.V497
Fire-resistance Ratings - ANSI/UL 263
Page Bottom
Design/System/Construction/Assembly Usage DisclaimerAuthorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of ULCertified products, equipment, system, devices, and materials.Authorities Having Jurisdiction should be consulted before construction.Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance withapplicable requirements. The published information cannot always address every construction nuance encountered in the field.When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the productmanufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for eachproduct category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternatemethods of construction.Only products which bear UL's Mark are considered Certified.
BXUV - Fire Resistance Ratings - ANSI/UL 263
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for CanadaSee General Information for Fire-resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. V497May 27, 2015
Nonbearing Wall Rating - 1 Hr
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (suchas Canada), respectively.
1. Floor and Ceiling Runners — (Not Shown) — Channel shaped, fabricated from min 25 MSG corrosion-protectedsteel, min width to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24in. OC max.
2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min 3-5/8 in. wide, min 1-1/4
in. flanges, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height.
3. Laminating Compound — For use with Item 4 - Used to bond outer layer wallboard to inner layer wallboard. Powdertype mixed with water in accordance with instructions shown on bags. Applied to entire surface of base layer wallboard.Applied with notched trowel producing continuous beads about 1/4 in. wide and 1/4 in. high.
4. Gypsum Board* — Applied to one side of steel studs (Item 2). Two layers of 5/8 in. gypsum panels with beveled,square or tapered edges. Gypsum panels applied vertically with joints centered over studs. Base layer applied with 1 in.Type S screws spaced 24 in. oc. Face layer applied vertically with joints centered over studs and offset from base layerjoints by 24 in. Face layer applied with 1-5/8 in. Type S screws spaced 12 in. oc starting with a 6 in. offset from thebottom of the gypsum panel.
NATIONAL GYPSUM CO — 5/8 in. thick Type eXP-C, FSL, FSW, FSK, FSW-3, FSW-5, FSW-G, FSK-G, FSW-6, FSW-8,FSW-C, FSMR-C, FSK-C, SoundBreak XP Type X Gypsum Board
4A. Gypsum Board* — (As an alternate to Items 3 and 4) - Applied to one side of steel studs (Item 2). Three layers of5/8 in. gypsum panels with beveled, square or tapered edges. Gypsum panels applied vertically with joints centered overstuds. First layer applied with 1 in. Type S screws spaced 24 in. oc. Second layer applied vertically with joints centeredover studs and offset from base layer joints by 24 in. Second layer applied with 1-5/8 in. Type S screws spaced 24 in.oc. Face layer applied vertically with joints centered over studs and offset from second layer joints by 24 in. Face layerapplied with 2-1/4 in. Type S screws spaced 12 in. oc starting with a 6 in. offset from the bottom of the gypsum panel.
NATIONAL GYPSUM CO — 5/8 in. thick Type eXP-C, FSL, FSW, FSK, FSW-3, FSW-5, FSW-G, FSK-G, FSW-6, FSW-C,FSMR-C, FSK-C, SoundBreakXP Type X Gypsum Board
4B. Gypsum Board* — (As an alternate to 5/8 in. Type FSW in Item 4A) - Nom. 5/16 in. thick gypsum panels appliedvertically. Two layers of 5/16 in. for every single layer of 5/8 in. gypsum board described in Item 4A. Horizontal joints onthe same side need not be staggered. Inner layer of each double 5/16 in. layer attached with fasteners, as described initem 4A, spaced 24 in. OC. Outer layer of each double 5/16 in. layer attached per Item 4A.
NATIONAL GYPSUM CO — Type FSW
5. Joint Tape and Compound — (Not Shown) - Joints covered with joint compound and paper tape. Paper tape, nom 2in. wide, embedded in first layer of compound over all joints of outer panels.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cULCertification (such as Canada), respectively.
Last Updated on 2015-05-27
Questions? Print this page Terms of Use Page Top
© 2017 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-UpService. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directorywith permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice inthe following format: "© 2017 UL LLC".
Design No. V497BXUV.V497
Fire-resistance Ratings - ANSI/UL 263
Page Bottom
Design/System/Construction/Assembly Usage DisclaimerAuthorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of ULCertified products, equipment, system, devices, and materials.Authorities Having Jurisdiction should be consulted before construction.Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance withapplicable requirements. The published information cannot always address every construction nuance encountered in the field.When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the productmanufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for eachproduct category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternatemethods of construction.Only products which bear UL's Mark are considered Certified.
BXUV - Fire Resistance Ratings - ANSI/UL 263
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for CanadaSee General Information for Fire-resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. V497May 27, 2015
Nonbearing Wall Rating - 1 Hr
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (suchas Canada), respectively.
1. Floor and Ceiling Runners — (Not Shown) — Channel shaped, fabricated from min 25 MSG corrosion-protectedsteel, min width to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24in. OC max.
2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min 3-5/8 in. wide, min 1-1/4
Design No. V497BXUV.V497
Fire-resistance Ratings - ANSI/UL 263
Page Bottom
Design/System/Construction/Assembly Usage DisclaimerAuthorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of ULCertified products, equipment, system, devices, and materials.Authorities Having Jurisdiction should be consulted before construction.Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance withapplicable requirements. The published information cannot always address every construction nuance encountered in the field.When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the productmanufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for eachproduct category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternatemethods of construction.Only products which bear UL's Mark are considered Certified.
BXUV - Fire Resistance Ratings - ANSI/UL 263
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for CanadaSee General Information for Fire-resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. V497May 27, 2015
Nonbearing Wall Rating - 1 Hr
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (suchas Canada), respectively.
1. Floor and Ceiling Runners — (Not Shown) — Channel shaped, fabricated from min 25 MSG corrosion-protectedsteel, min width to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24in. OC max.
2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min 3-5/8 in. wide, min 1-1/4
2
SCALE: 3" = 1'-0"1 NEW ONE HOUR CORRIDOR WALL BASE DETAIL
SCALE: 3" = 1'-0"2 NEW ONE HOUR CORRIDOR TOP OF WALL DETAIL
SCALE: 3" = 1'-0"3 CONVERTED ONE HOUR WALL BASE DETAIL
SCALE: 3" = 1'-0"4 CONVERTED ONE HOUR TOP OF WALL DETAIL
SCALE: 3" = 1'-0"5 NEW UNRATED WALL BASE DETAIL
SCALE: 3" = 1'-0"6 NEW UNRATED TOP OF WALL DETAIL
SCALE: 1:1.117 CONVERTED ONE HOUR WALL ASSEMBLY
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
OV
ER
ALL
DE
MO
LITI
ON
PLA
N
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
AD1.0
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
11 22201918171615141312109765432
H
G
E
D
B
A
1
E1
C1
8a 21
PLANNORTH
F.E.
F.E.
F.E.
F.E
.
C
C
18' 18'-2"
1'-4
"
1'-1"
(E) elec.closet
to remain
8
15
15
15
15 15 15 1515 15 15 15 15 15 15 15 15 17 15 15
17
1715 15 15 15
15 1515 15 15 15 15 15 15 1515
15
17
142 2 2
2
2
2 2 2
2
2
17
17
17
16
9 12
5
7
7
9
10
5
7
(E) ASB
ESTOS T
ILE
(E) Q
UAR
RY T
ILE
(E) ASBESTOSTILE(E) CARPET
19
5
7
7
(E) HEADERTO REMAIN
(E) CARPETOVER
CONCRETE
5
3
REMOVE THISPORTION OF WALL
14
1 1 1
1
7
6 11
6 11
6 11
6 11
7 7 5
712
6 11
6 116 11
6 11
6 11
6 11
1
1
6 11
6 11
5
6
11
5
5
7
7
7
5
5
555
7
6 11
6 11
6 136 136 13
6 11
5
5
6 11
55
6 11
6 11
5
7
6 11
6 11
6 11
6 11
6
12 13
5
18
6
11
611
6
11
6
11
7
6
11
5
7
6
11
6
13
5
76
11
5
6 11
7
6 13
9 9
12 11 1211
(E) QUARRY TILE
4
(E) Q
UAR
RY
TILE
(E) ASBESTOS TILE
(E) CARPETOVER
CONCRETE(E) QUARRY TILE
6
13
6
13
6
136
13
6
13
1313
6
12
13
6
13
6
13
12
13
11 6
6
12
13 6
6
11
5
7
5
7 12
116
11
7
55
7
12
115
7
6
11
5
6
11
5
7
6
11
5
1313 6
6
5
7
12 13
12
13
12
13
13 6
6
5
7
5
7
6
11
6
11
5
57 7
207
5
6 13
611
13
13
11
6
7
6
15
33
19197
19
19 19 19
19
19
19191919
REMOVE THISPORTION OF WALL
6
12
12
5
6
12
6
6
12
12
12
12
12
1
1
(E) CARPET
(E) CARPET
13
21
2122
NO WORKPROPOSED
NO WORKPROPOSED
NO WORKPROPOSED
NO WORKPROPOSED
EP EP
EP
EP
typ. typ. typ.
typ.
typ.
typ. typ. typ.
typ.
typ.
(E) CORRIDOR
(E) LOBBY
(E) LOBBY
(E) CORRIDOR(E) CORRIDOR
(E) CORRIDOR(E) CORRIDOR(E) CORRIDOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
KEY NOTES
remove (E) INTERIOR WINDOW
(e) exterior wall to remain - typ. u.n.o.
(E) recessed trash RECEPTACLE to remain
(E) WATER FOUNTAIN TO BE REMOVED
remove (e) casework, and fixtures TO ACCOMMODATE (N) WORK
remove (e) act ceiling, and GRID typ. u.n.o.
(E) CEILING SOFFIT FRAMING TO BE REMOVED
(e) DUMBWAITER, SHAFT LINER AND CONTROLS TO BE REMOVED
remove (e) restroom fixtures and cap plumbing pipes
(E) 2'X2' BUILT-IN SHOWER PAN TO BE REMOVED
(E) ASBESTOS OR VINYL TILE TO REMAIN. STRIP WAX. REMOVE (E) RESILIENT BASE.
REMOVE (E) HARD LID CEILING AND SUPPORT FRAMING
REMOVE EXISTING CARPET AND RESILIENT BASE THROUGHOUT. DO NOT DISTURB UNDERLYING ASBESTOS TILE. STRIP WAX FROM TILE.
(e) DUCTWORK, PLYWOOD, AND PARTIAL GLAZING TO BE REMOVED AND replaced W/ (N) GLAZING TO MATCH EXISTING.
(e) exterior window to remain
(e) exterior door to remain
(E) door/WINDOW STOREFRONT to remain
(e) QUARRY TILE FLOOR to remain. STRIP WAX FROM TILE.
(e) SOFFITED CEILING to remain
(E) RECESSED SPECIMEN PASS-THROUGH CABINET TO BE REMOVED AND REPLACED
portion of (E) quarry TILE or ASBESTOS tile flooring TO be removed by abatement contractor. GENERAL CONTRACTOR RESPONSIBLE FOR INSTALLING UNDERLAYMENT AND (N) FLOORING IN THESE AREAS.
REMOVE ALL (E) CORNER GUARDS, TYP.
DEMOLITION LEGEND
(E) INTERIOR WALL TO REMAIN
(E) INTERIOR WALL TO BE DEMOLISHED
(E) DOOR, FRAME AND THRESHOLD TO BE REMOVED
(E) INTERIOR WINDOW TO BE REMOVED
(E) HARD-LID CEILINGTO BE REMOVED
EP (E) ELECTRICAL PANEL TO REMAIN
HAZARDOUS MATERIALS ABATEMENT NOTES:
1. SEE “LIMITED ASBESTOS & LEAD BASED PAINT SURVEY REPORT” BY S TECH CONSULTING
DATED NOVEMBER 18, 2016 THAT IS APPENDED TO PROJECT SPECIFICATIONS. THIS REPORT
IDENTIFIES LOCATIONS OF EXISTING DETECTED ASBESTOS AND LEAD PAINT ON THE FIRST
FLOOR OF 1080 EMELINE.
2. THE COUNTY WILL ABATE THE ACOUSTICAL PLASTER IN THE LOBBY, TSI FITTINGS, TRANSITE
COUNTERTOPS AND SPLASHES, AND CERAMIC TILE WAINSCOTING IN EXISTING AFFECTED
RESTROOMS. THIS WORK WILL BE DONE UNDER A SEPARATE CONTRACT.
3. EXISTING ASBESTOS CONTAINING FLOOR TILE AND MASTIC AND CEMENT PANELS UNDER
EXISTING EXTERIOR WINDOWS WILL REMAIN IN PLACE. GENERAL CONTRACTOR TO MINIMIZE
DISRUPTION TO THESE MATERIALS.
4. PRIOR TO ABATEMENT TAKING PLACE, THE GENERAL CONTRACTOR WILL NEED TO
COMPLETE SPECIFIC DEMOLITION ITEMS TO ALLOW ACCESS TO AREAS CONTAINING
ASBESTOS AND/OR LEAD CONTAINING MATERIAL. THESE AREAS INCLUDE, BUT ARE NOT
LIMITED TO:
a. ACOUSTICAL CEILING TILE AND GRID
b. EXISTING GYPSUM HARD LID CEILINGS
c. LIGHT FIXTURES AND HVAC REGISTERS BEING SUPPORTED BY THESE CEILINGS
d. ANY AFFECTED DUCTWORK SCHEDULED TO BE REPLACED OR RELOCATED
AND BLOCKING ACCESS TO ASBESTOS CONTAINING MATERIALS
E. EXISTING CARPETING
5. CONTRACTOR TO NOTIFY OWNER IMMEDIATELY IF, DURING THE COURSE OF CONSTRUCTION,
OTHER SUSPECT MATERIALS ARE FOUND. SUCH MATERIALS ARE NOT TO BE DISTURBED
UNTIL THEY HAVE BEEN ASSESSED FOR HAZARDOUS CONTENT.
6. general CONTRACTOR will coordinate with mechanical and electrical engineers
to discern the best locations to cap systems to minimize disruption and
contamination of occupied areas prior to commencement of work.
2
2
2
2
2
SCALE: 3/32" = 1'-0"1 DEMOLITION PLAN
2
DATE
Job:Sheet
Date:Scale:Drawn:
REVISIONS05/22/2017BID SET
07/07/2017ADDENDUM #2
BY
6/30/17Plotted On:
6/30/17AS NOTED
OV
ER
ALL
BA
SE
ME
NT
CE
ILIN
G D
EM
OLI
TIO
N P
LAN
CO
UN
TY
OF
SA
NTA
CR
UZ
10
80
EM
EL
INE
AV
EN
UE
SA
NTA
CR
UZ
, C
A 9
50
60
1080
EM
ELI
NE
FIR
ST
FLO
OR
RE
MO
DE
L
SE
AL
/Use
rs/V
ivi/D
ropb
ox/1
080
EM
ELI
NE
RE
MO
DE
L/A
rchi
cad/
1080
EM
ELI
NE
RE
MO
DE
L.pl
nA
RC
HIC
AD
MA
STE
RTE
MP
LATE
[TM
] BY
BO
BR
OW
CO
NS
ULT
ING
GR
OU
P |
ALL
RIG
HTS
RE
SE
RV
ED
| w
ww
.bob
row
.com
| w
ww
.arc
hica
dtem
plat
e.co
m
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.
1" ACTUAL
THE ARCHITECT MUST BE NOTIFIEDOF ANY DISCREPANCY INDIMENSIONS, FIELD CONDITIONS OROTHER INFORMATION THAT ISCONTAINED IN AND/OR DIFFERSFROM THESE DOCUMENTS.
THESE DOCUMENTS ARE THEPROPERTY OF THE ARCHITECT ANDMAY NOT BE USED ORREPRODUCED WITHOUT WRITTENCONSENT. THE ARCHITECTDISCLAIMS ANY RESPONSIBILITYRESULTING FROM UNAUTHORIZEDUSE.
COPYRIGHT STARTS FROM THEDATE OF THE EARLIEST CONTRACTTHROUGH CONSTRUCTIONDOCUMENTS.
AD1.1
MR
MR / DR
ARCH ITECT
DESNECIL MONICA MRATLIFFC 26817
CALIFORNIA
FOETATS RENEWALDATE
10/31/17★★
MR
11
UP
22201918171615141312109765432
H
G
E
D
B
A
1
E1
C1
8a 21
C
C
SALVAGE ANDREINSTALL
CEILING TILEIN THIS ROOM
ADMINRECORDS
EPEP
EP
EP
EP
EP
AUDITORIUMACT 2'x4'
CH: 132.00"
AUDITORIUMACT 2'x4'
CH: 132.00"
WALK-INCOOLER
WALK-INCOOLERMETAL CLG.
STORAGEHARD LIDCH: 96.00"
STAIR
CHARTROOMACT 1'X1'
CH: 117.00"
TRAININGROOM
MEDICALSTO.
CUSTOD
IAL
STORAGE
COMP.MAINFRAME
COMP.MAINFRAME
custodian
MRESTR'M
FRESTR'M
BREAKACT 2'X4'CH: 96.00"
STO.
LABSTO.
EXPOSEDGLG.
DATA
RECORDS STO.
BOILERR'M
EXPOSEDGLG.
HAZARDOUSWASTE
GENERATOR
STO./CHARTROOM
EXPOSEDGLG.
STAIR
CORR.HARD LIDCH: 96.00"
MEETING ROOM
CORR.ACT 2'X4'CH: 96.00"
CORRIDORCORRIDOR
CORRIDOR
HOUSEK
EEP
ING
ELEVATORS
HARD LIDCH: 96.00"
MAINT.STOR.
EXPOSEDGLG.
MAINT.STOR.
ACT 2'X4'CH: 96.00"
ACT 2'X4'CH: 96.00"
ACT 2'X4'CH: 96.00"
HARD LIDCH: 132.00"
HARD LIDCH: 132.00"
HARD LIDCH: 96.00"
DEMOLITION LEGEND
(E) INTERIOR WALL TO REMAIN
indicates area of ceiling to be removedby general contractor TO ALLOW ACCESSFOR ABATEMENT AND (N) PLUMBING WORK.CONTRACTOR SHALL REPLACE CEILINGTO MATCH EXISTING UPON COMPLETION OF WORK.
EP (E) ELECTRICAL PANEL TO REMAIN
indicates EXPOSED ceiling AREAWITH (N) PLUMBING WORK THATMAY REQUIRE ABATEMENT.
2
SCALE: 3/32" = 1'-0"1 BASEMENT CEILING DEMOLITION PLAN
HAZARDOUS MATERIALS ABATEMENT NOTES:
1. THE COUNTY WILL ABATE EXISTING LEAD AND ASBESTOS.
THIS WORK WILL BE DONE UNDER A SEPARATE CONTRACT.
2. PRIOR TO ABATEMENT TAKING PLACE, THE GENERAL CONTRACTOR WILL NEED TO
COMPLETE SPECIFIC DEMOLITION ITEMS TO ALLOW ACCESS TO AREAS CONTAINING
ASBESTOS AND/OR LEAD CONTAINING MATERIAL. THESE AREAS INCLUDE, BUT ARE NOT
LIMITED TO:
a. ACOUSTICAL CEILING TILE AND GRID
b. EXISTING GYPSUM HARD LID CEILINGS
c. ANY AFFECTED LIGHT FIXTURES AND HVAC REGISTERS
BEING SUPPORTED BY THESE CEILINGS
d. ANY AFFECTED DUCTWORK SCHEDULED TO BE REPLACED OR RELOCATED
AND BLOCKING ACCESS TO ASBESTOS CONTAINING MATERIALS
3. CONTRACTOR TO NOTIFY OWNER IMMEDIATELY IF, DURING THE COURSE OF CONSTRUCTION,
OTHER SUSPECT MATERIALS ARE FOUND. SUCH MATERIALS ARE NOT TO BE DISTURBED
UNTIL THEY HAVE BEEN ASSESSED FOR HAZARDOUS CONTENT.
4. general CONTRACTOR will coordinate with mechanical and electrical engineers
to discern the best locations to cap systems to minimize disruption and
contamination of occupied areas prior to commencement of work.