Upload
tran-thanh-tung
View
227
Download
0
Embed Size (px)
Citation preview
8/13/2019 Monolithic Insulating Joints
1/5
MONOLIThIC
INSULATing
JOINTsRL
Carpenteria meccanica
Luigi Rota
8/13/2019 Monolithic Insulating Joints
2/5
RL
Carpenteria Meccanica Luigi Rota operates for more than 25 years in the field of structural metalwork
construction and industrial assemblies and has been specializing in the production of monolithic
insulating joints for pipelines.
AREAS AND PLANTS Covered area : Off ices 200 m2 Warehouse: 2000 m2
Open area : 2000 m2
EMPLOYEES 15 peop le All our staff is high ly qual ified and spec ial ized.
MAIN EQUIPMENT
n.2 bridge cranes of 20 T
n.1 fork lift
semi-automatic belt units for cold-cutting of pipes
tool-machines for horizontal and vertical turningbevelling machines - electrical - hand-operated and semi-automatic
welding units: GTAW, GMAW, SMAW and SAW equipment
hydraulic vertical presses - air compressors
CERTIFICATES
UNI EN ISO 9001:2008 EA17 sector, Reg. number: 0312294 PED Modulo H1
CARPENTERIA MECCANICA LUIGI ROTAsince 1983
FOR ONSHORE AND OFFSHORE PROJECTS
Carpenteria Meccanica Luigi Rota produces and distributes high quality monol ithic insulating joints for
the oil&gas industry. Wherever you find pipeline and gas distribution systems you will also find a widearray of our products.
When our monolithic insulating joints are used in the right application, savings in the overall costs of
the entire corrosion control system are granted.
FOR ONSHORE PROJECTS
Limiting the spread and hence the cost of cathodic protection to those pipes that need to be effectivelyand economically protected by the main cathodic protection system.
Electrically dividing long pipelines into distinctive cathodic protection system.
Isolating a pipeline and ensuring that cathodic protection or stray electricity currents do not causeincreased corrosion.
Providing protection against earthing currents at domestic and industr ial premises where the PME system
is in use.
FOR OFFSHORE PROJECTS
Isolating the pipeline cathodic protection system in riser pipes and offshore structures.
At field tie-ins.
DEMANGING APPLICATIONS
Making dependable isolation joints with dependable seals for safety-critical and extreme applicationsgoes beyond excellence in design and manufacturing.
It also means a strong commitment to quality.
Carpenteria Meccanica Luigi Rota as a major isolation joints manufacturer, has access to substantial
application data and a wealth of experience. Our practical know-how in using very complex and secure
methods is supported by finite element analysis to combine experience and technology at the same time.
The most extreme environments demand a strong commitment in finding the best sealing solution.Carpenteria Meccanica Luigi Rota is committed in achieving its objectives in very demanding services
for high pressure or hard vacuum applications as well as against corrosive chemical and very low
temperature in-line services.
MATERIAL STANDARDS
Ferrous materials : ASTM, API, UNI, ANSI, DIN, BS, ASME, MSS, NACEFor dielectric non ferrous materials : ASTM, CEI.
For resinous materials, paints & sand-blasting : ASTM, SPPC, ISO, SIS, BS.
For welding & related materials : AWS, ASME IX, ASME II Part. C, BS 4515 EN
NDE Examinations and inspections: ASME V, ANSI B 31.3, ANSI B 31.4, ANSI B 31.8, ASME VIII, API 1104.
Monolithic Insulating Joints
II 2 G c IIC T6
ATEX 94/9/CEMODULO H 1
direttiva 97/23/CE
8/13/2019 Monolithic Insulating Joints
3/5
RL
DESIGN & CALCULATIONS
Our company uses a computer calculation programme for the check of the jointsmechanical properties,
in compliance with ASME VIII Div. 1 App. 2 and applicable Codes (ANSI B 31.3, 31.4, 31.8), or accordingto the Clients specific requirements.
A finite element method check programme (ASME NQA-1 certi fied programme) is operative and available
in our technical department.
QUALITY ASSURANCE
Carpenteria Meccanica Luigi Rota has a Quality Assurance System in accordance with the requirements
of UNI EN ISO 9001:2008. This ensures a close control over all production and manufacturing stages.Our staff and personnel are committed in producing top quality products and are very proud of their
reputation within the Petrochemical Industry as a certi fied Company.
TESTING & INSPECTION AGENCIES
Bureau Veritas, Lloyd Register, Det Norske Veritas , American Bureau of Shipping, RINA, Cipex, Socotec,
EIL, Crown Agents, MMI, TUV, Germanischer Lloyd, ecc
MAIN PRODUCTS
- MONOLITHIC INSULATING SERVICE JOINT
For gas and water with maximum working pressure of 10 Bar
NPS from to 3 Line production.
- MONOLITHIC INSULATING JOINTS FOR PIPELINES
Working pressure from ANSI rating 150 to 2500 and up to API 10000
NPS from to maximum pipe line OD.
- PRE-ASSEMBLED INSULATING FLANGES
Manufactured in compl iance with the client s design and specifications oraccording to our patent for high pressure joints.
DESIGN & MATERIAL CODES ASME ANSI ASTM BS UNI DIN
SIZE RANGE From to 100
ELECTRIC CHARACTER ISTICS Electric insulation resistance >200 M
Monolithic Insulating Joints
Norme prodotto:
UNI-CIG 11105
Pressione Massima di ESERCIZIO: 64 BarPressione Massima di COLLAUDO: 96 Bar
21.3
26.7
33.4
42.4
48.3
60.3
76.1
88.9
114.3
141.3
168.3
219.1
273
323.8
355.6
406.4
457.2
508
558.8
609.6
660.4
711.2
762
812.8
863.6
914.4
965.2
1016
1066.8
1219.2
1422.4
mm
1/2
3/4
1
11/4
11/2
2
21/2
3
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
48
56
Pollici
15
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
930
950
1000
1050
1200
1400
Dn
250
250
250
300
300
350
350
500
500
600
600
600
800
800
1000
1000
1000
1200
1200
1200
1200
1300
1300
1300
1300
1400
1400
1400
1400
1800
2500
L
60
60
60
70
80
92
102
120
135
160
170
190
214
234
250
270
290
300
320
340
350
360
370
400
410
430
440
460
470
560
625
B
95
95
95
113
150
150
150
190
182
220
215
205
293
283
375
365
355
450
440
430
425
470
465
450
495
485
480
470
465
620
937
C
3.2
3.3
3.4
3.6
3.7
3.9
4.5
5.5
6.0
6.5
7.1
8.2
9.3
9.5
12.7
12.7
12.7
12.7
12.7
12.7
14.3
14.3
17.5
19.0
19.0
20.6
22.2
23.8
25.4
25
25
Sp
PN 64 Bar - ANSI 300/400
Norme prodotto:
UNI-CIG 10284 (per PN 10)UNI-CIG 10285 (per PN 25)
Pressione Massima di ESERCIZIO: 25 BarPressione Massima di COLLAUDO: 38 Bar
21.3
26.7
33.4
42.4
48.3
60.3
76.1
88.9
114.3
141.3
168.3
219.1
273
323.8
355.6
406.4
457.2
508
558.8
609.6
660.4
711.2
762
812.8
863.6
914.4
965.2
1016
1066.8
1219.2
1422.4
mm
1/2
3/4
1
11/4
11/2
2
21/2
3
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
48
56
Pollici
15
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
930
950
1000
1050
1200
1400
Dn
250
250
250
300
300
350
350
500
500
600
600
600
800
800
1000
1000
1000
1200
1200
1200
1200
1300
1300
1300
1300
1400
1400
1400
1400
1800
2500
L
60
60
60
70
80
92
102
120
135
160
170
190
214
234
250
270
290
300
320
340
350
360
370
400
410
430
440
460
470
560
625
B
95
95
95
113
150
150
150
190
182
220
215
205
293
283
375
365
355
450
440
430
425
470
465
450
495
485
480
470
465
620
937
C
3.2
3.3
3.4
3.6
3.7
3.9
4.5
5.5
6.0
6.5
7.1
8.2
9.3
9.5
12.7
12.7
12.7
12.7
12.7
12.7
14.3
14.3
17.5
19.0
19.0
20.6
22.2
23.8
25.4
25
25
Sp
PN 100 Bar - ANSI 600
21.3
26.7
33.4
42.2
48.3
60.3
76.1
88.9
114.3
141.3
168.3
219.1
273
323.8
355.6
406.2
457.2
508
558.8
609.6
660.4
711.2
762
812.8
863.6
914.4
965.2
1016
1066
1219.2
1422.4
mm
1/2
3/4
1
11/4
11/2
2
21/2
3
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
48
56
Pollici
15
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1200
1400
Dn
250
250
250
300
300
350
350
400
400
500
500
500
700
700
900
900
900
1000
1000
1000
1000
1100
1100
1100
1100
1200
1200
1200
1200
1400
1900
L
43
50
58
68
75
98
116
135
161
195
229
280
355
406
442
498
552
602
660
712
790
841
894
946.8
997.6
1048
1099
1156
1208
1359
1562
B
101
98
97
120
120
142
138
160
158
207.5
210
198
287
280
350
345
335
382.5
376
366
356
396
396
375
375
415
415
395
395
480
695
C
3.2
3.2
3.4
3.6
3.7
3.9
4.5
4.8
4.8
4.8
5.56
6.3
6.3
7.14
8
7.92
8
8
8
8
8
8
8
10
10
10
12
12
12
12
12
Sp
PN 25 Bar - ANSI 150
Norme prodotto:
UNI-CIG 11105
Pressione Massima di ESERCIZIO: 100 BarPressione Massima di COLLAUDO: 150 Bar
Table A
Insulating joint welding/welding
8/13/2019 Monolithic Insulating Joints
4/5
RLThanks to the reliability of our insulating joints, with regards to the anti-corr osion
protection of buried pipelines, Carpenteria Meccanica Luigi Rota ensures the safestand most economical operation of pipelines and distribution networks for gas, waterand other hydrocarbons owing to:
the very high reliability of its products; the special manufacturing accuracy; the severe and continuous quality controls implemented in the manufacturing process the original and new designs as illustrated in Fig.1and Fig.4
The S-TYPE JOINTS (Fig. 1) are manufactured for pressures and diameters inaccordance with table A and section 1,2,3, and 4 (Fig. 2), respecting (Fig. 3).
DIAMETER AND PRESSURE LIMITS OF STANDARDPRODUCTI ON JOINTS T 70C
ND mm(inches)CLASS PRESSURE (bar)
CARP. ROTA ANSI WORKING TESTING
From 15 (1/2) to 2500 (100) PN 25 150 25 38
From 15 (1/2) to 1500 (60) PN 64 - 100 300 - 600 64 - 100 96 150
From 15 (1/2) to 1400 (56)PN 150 250 and
over900 1500
2500150 250and over
225 375and over
Fig. 1S-TYPE
Fig. 4IP-TYPE
Fig. 2
2 3 4
321
100-1254"-5"
ND151/2"
300-35012"-14"
PN 100
PN 64
PN 25
3" -4"80-100
1/2"ND15
12" -14"300-350
140056"
150060"
2500100"
(1500)60"
Fig. 3
The S-TYPE JOINTS(Fig. 1) are constructed for pressures and diameters in accordance with tableA and section 1,2,3, and 4 (Fig. 2), respecting (Fig. 3).
MONOLITIC INSULATING JOINT for MAINLINESMATERIALS
Pipe sections Carbon steel pipes in according to API 5L and ASTM, UNI , DIN and BS
Rolled plates,relevant to the above mentioned specifications longitudinally arc welded (SAW)
Joint body Welded construction out of rings from heavy thickness rolled plates Laminated or forged rings, in accordance with UNI , ASTM and DIN
Insulating materials From epoxy-glass laminates or epoxy glass prefabrications in accordance with ASTM
From polycarbonates From cold-cured epoxy resins
Sealing gaskets From nitril e, fluor ide and silicone elastomers in accordance with ASTM
Coatings Interna l surface : epoxy resins (fusion bonded epoxy) External surface: epoxy primers epoxy paints or specia l high build coatings
WELDING AND NON DESTRUCTIVE TESTING
The metal components that make up the so-called standard joints are joined together by meansof fillet welds if requested, the fillet weld seam may be checked by non destructive tests usingdye penetrants and magnetoscopic inspections.
With different preparation butt welds can be used. In this case, inspect ions by x-rays andultrasounds can be carried out.
All welding processes are in accordance with ASME VIII and IX and are certif ied by independent andInternational Authorities.
TESTS
Sample joint testing or individual joint testing are carried out to guarantee the following minimal values: Hydrostatic test pressure: 1.5 times PN. Dielectric tests (in air and on dry joints) * Electr ical resistance: 5 megohms minimum; tension: 1 kV d.c.
* Resistance to appl ied tension (without discharge): 3 kV / 50 Hz for 1minute
Upon request CARPENTERIA ROTA may supply insulating joints which have been subjected to thefollowing supplementary tests:
Electr ical resistance, when joints are filled with water
L* p = water resistance (ohm x cm) R = p ------ where L* = length of lined internal wall (cm) S S = sectional flow area (sq.cm)
Cyclic hydraulic tests Hydrostatic tests with welded and plates Air-tightening tests Dielectric tests after immersion in 3% NaCI solut ion
*Additional tests are performed according to costomers requirements and/or specifications.
Technical data and warranties
8/13/2019 Monolithic Insulating Joints
5/5
studiolumiere.i
t
Carpenteria Meccanica Luig i RotaVia sforzatica 15 - 24040 Lallio (BG) - italy
C.f.: RTOLGU54A16L404R - P.Iva: 01005570161
Tel. (+39) 035 690 229 - Fax 035 200 971
E-Mail: [email protected]
www.carpenteria-rota. i t
http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/http://www.studiolumiere.it/