Model No.24DT0=Thermometer onlyS = SST CoverL = with Light SwitchPower0=12Vac./dc4=110Vac.

5=230Vac.

DisplayF = °F -40/230°FC = °C -40/110°CUpdate Time*0 = 1 Second1 = 1 Minute3 = 3 MinuteEx: 24DT-L-4F1

Wall Plate Thermometer / 120 Vac / Light Switch /1 Minute Update

The New Generation LED Thermometers include our exclusive Direct Power Feature eliminating theneed for an external transformer. Powered by 120Vac, (230Vac,12Vac, optional) not only makes theunit easier to install but adds reliability and life to the instrument. With UL and NSF Listing, both designscan be ordered with 1 second,1 minute or 3 minute display update times to eliminate temperaturefluctuations from repeated door openings. Each unit has a detachable sensor and power fast-onsto speed up installation. With an extended range of –40 to 230°F our LED units are well suited tomany applications. Includes Temperature Probe and Wiring Harness.**20DT only.

Option: 9V Back-up Battery Harness (9V Battery not Included)

How to Order LED Thermometers

Model No. Mounting20DT U = U-Clamp

F = Front FlangePower0 = 12 Vac/dc4 = 120 VacDisplayF = -40/230°FC = -40/110°CUpdate Time*0 = 1 Second1 = 1 Minute*3 = 3 Minute*Order Entry Example: 20DTF-4F12" Front Flange / 120 Vac / °F / 1 Second Update

*Display changes 1° every 1 or 3 minutes on increase of temperature –

on decreasing temperature, the display will change every second,

regardless of time.

Thermometers

2

24DT 20DT 24DT-S 24DT-LAlso available in Blue Display

Page 3: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

The e-Class series of controls are the OEM choice for Economy, Efficiency and Easiness. Designed for the North American Market, the e-Class features high quality components builtin a state of the art factory in Northern Italy. Simplified parameters, Hot Key Programming forWarming, Medium and Low Temp Refrigeration. Extra Large Relay’s assure long life. 1/4"Fast-on Connectors ideal for OEM production assembly.

SPECIFICATIONS:Power: 120V / 230Vac 50/60hzOutputs:16FLA/96LRA,16A RES.10A DEF

5A FAN (see model differences)Inputs: 1 NTC / PTCRange: -40 / 230 or 302°FProtection: IP65Digital Inputs: 0-1

Display: 2 or 3 DigitsIcons: 3 Connections: Probes disconnectableOutputs: 1/4" fast-onHot Key: YesTTL: NoApprovals:

XR01CX

Heating / Warming

XR02CX

Medium Temp Refrigeration

XR03CX

XR04CX

Alarm / Defrost

XR06CX

Low Temp Refrigeration

e-Class

3

MODEL RC

Page 4: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

4

Prime Series

The Dixell Prime Series configurable controllers provide digital solutions for both mediumtemperature and low temperature refrigeration units. Depending on the model the installercan adjust through the parameter menu such fields as set point, differential, short cycleprotection, energy savings temperature differential, digital input configuration, fan cyclingplus alarm levels and delays. Included TTL Modbus communications via Hot Key port.

SPECIFICATIONS:Power: 120V / 230Vac 50/60hzOutputs:16FLA/96LRA,10A, 5A

(see model differences)Inputs: 1-3 NTC / PTCRange: -40 / 230 or 302 °F/CProtection: IP65Digital Inputs: 1

Display: 3 DigitsIcons: 8 Connections: Probes disconnectableOutputs: 1/4" fast-onHot Key: YesCommunications: TTL / Modbus

Approvals:

XR20CX

Medium Temp Refrigeration (Off Cycle Defrost)

XR30CX

XR40CX

Alarm / Defrost

MODEL RC

Page 5: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

5

Prime Series

How to Ordere-Class

XR01CX Voltage Sensor Options F/C Relay / Connectors4= 120Vac N = NTC 0 = None F = °F 7 = 16FLA / 1/4" Fast-ons5 = 230Vac P = PTC 1 = Buzzer C = °C

XR02CX 4= 120Vac N = NTC 4 = None F = °F Q = 16FLA / 1/4" Fast-onsXR03CX 5 = 230Vac 5 = Buzzer C = °C (Short Case)

XR04CX (no Buzzer on XR03CX) 7* = 16FLA / 1/4" Fast-onsXR06CX* (Std. Case XR06CX)

Prime SeriesXR10CX Voltage Sensor Options F/C Relay / ConnectorsXR20CX 0 = 12AC/DC N = NTC 0 = None F = °F 7 = 16FLA / 1/4" Fast-onsXR30CX 1 = 24AC/DC P = PTC 1 = Buzzer C= °C 8 = 16/60A 1/4" Fast-onsXR40CX 4 = 120Vac P = PT1000 (XR70CX only)

XR60CX 5 = 230Vac (XR30 / 70 only)

XR70CX

Other Options: Consult the factory

XR60CX

Low Temp RefrigerationComp/ Def/ Fan

XR70CX

Low Temp RefrigerationComp/ Def/ Fan/ Alarm

Page 6: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

6

Universal-XR Controller

The Universal-XR controller offers a 7 in 1 solution for Heating/Medium & Low Temperature/Defrost / Fans /Alarms etc. in just one control. Select one of the six 6 Preset maps in theapplication menu, and you now have a replacement of virtually any control. It’s the onecontrol that is a must have on your service vehicle. Ultra simplified one does it all. The Universal-XR Advanced Map (tC=7) allows total flexibility with inputs and outputs.

tC = 1 XR10CX / XR01CX Heating

Heat / Med / LowTemp w/ Defrost w/ Fan w/ Alarm

tC = 3 XR02CX/XR20CE Med. Temp Time / Temp Def.tC = 2 XR20CX Med. Temp Time / Time Def.

tC = 4 XR03CX/XR30CX Med.Temp Time/ Temp/Alarm tC = 5 XR04CX/XR40C

tC = 6 XR06CX/XR60CX Low Temp Time/ Temp Def./Fan tC = 7 XR60CX Advanced

Page 7: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

7

XC Rack Controls

Dixell offers a full line of Compressor Rack Controllers for systems of all sizes. Projectspecifications may include working with multiple stages, compressors of differing power,condenser fans, digital scroll management, proportional band or dead band adjustments. Options on certain models can include alarm relay and analog outputs. Tell us about yournext project.

XC650CX XC645CX XC1015D

Circuits 1 1 2Compressors 2-5 2-5 2-15Digital Scroll no yes opt.Fans 1-3 1-3 1-15Unloaders yes yes yes

XC650CX Mini RackUp to 5 Comps and/or Fans

XC645CX 1 Digital Scroll + Up to 4 Comps and/or Fans

XC1015D Advanced Rack Control - 15 Relays outs +

4 Analogs outs

Page 8: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

8

XC Condenser Controls

The Dixell XC10 & 30CX Controls replace old Mechanical Pressure Switches that areinaccurate, difficult and time consuming to set up.The XC Controls can directly control a compressor and up to 2 fans (XC30CX model).It is possible to control the pressure values of the suction and discharging lines by using a new low cost ratio-metric pressure sensorinput. With the addition of a fixed Pressure Switch you can Shut down (and save) thecompressor on High Pressure Alarm conditions. The XC30CX will also Control up to twoCondenser fans, rotating them for equal run times. A Service Menu records information onStarts, Run Times, Manual Starts, and Alarms.

Comp + 2 Fans

XC30CX

Compressor Control

XC10CX

XC10CX XC30CX

Circuits 1 1Compressors 1 1Fans 0 1-2PSI Sensor 1 2

Ratio-Metric Transducer

Page 9: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

9

XWA Series

Operators can be certain that the temperature inside their walk-in stays in the safezone by indicating either a High or Low Temperature condition with a visual Alarm andpulsing Buzzer. An open door alarm keeps the cold inside where it belongs. A set ofAlarm contacts is included for outboard signaling. The Light Management System willautomatically turn the lights ON when you open the door and the "AUTO-OFF" featureshuts off the light after an adjustable time delay. Optional 9Vdc battery back up willallow for visual alarms for up to 96 hours.

SPECIFICATIONS:Power: 120V / 230Vac 50/60hzOutput: 8A alarm / 15A LightInputs: NTCRange: -40 / 230°FDisplay: 3 DigitsIcons: 3 J-Box Mount Connections: Probe 1/4" fast-ons

Outputs: 1/4” fast-on

Approvals:

MODEL RC

Alarm CodesHA High Temp Alarm dA Door open alarmLA Lo Temp Alarm Pan Panic AlarmP1 Probe Alarm EA External Alarm

XWA11VWalk-in Alarm & Light Manager

XWA11V-KITINCLUDES:Wall Mount EnclosureDoor SwitchExternal BuzzerPre-wired

ACCESSORIES INCLUDE:iDial Phone Dialer

MGS Leak Detector

PAN Panic Button

EXT/BUX External 85db buzzer

iDial1Includes ext. relay to convert 8Aalarm relay to D.I.Includes 9/12Vdc transformerRJ11 wires and instructions9 Programmable phone no’sfor each channel

MGSGas leak detector for refrigerantleaks. Various gases/rangesavailable.

STRStrobe light for visual alarmwarning

H300Current transformerto detect defrost.

MDSMagnetic door switch1/2" spacing magneticdoor switch to connect to digital input

PANPushbutton backlight panicalarm. The XWA will display"Pan" and turn on alarmrelay for external buzzer orphone dialer

Page 10: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

10

XJDL Series

Record up to 4 Temperatures every 15 minutes and Store up to 1 Year with the XJDL DigitalData Logger. Operators can take the guesswork and human error out of HACCP recording.Record up to 4 temperatures and 4 events, such as door openings or defrost cycles on a single unit. Data transfer to a PC with ease using a standard USB drive to a .TXT file thatcan be uploaded to Excel. Dated security prohibits tampering. A built-in dry contact relaycan be used for audible or visual alarms, phone dialer, BMS or security system interface.

KIT INCLUDES:• (4) 8 ft. NTC probes included –40/230°F&C

• Record every15 minutes and store for up to 1 year

• Download .TXT file to USB key/Upload to any PC & Excel®

• Hi & Low Alarm setpoints with dry contacts SPDT

• 4 door switch inputs

• 24V Plug-in transformer

• Wall mounting enclosure

Standard 10K Ohm NTC Thermistor -40/230°F

Nickel Brass 1.8" x ¼" Molded / Potted Probe18NB-NTC-1.5M 05ft18NB-NTC-2.5M 08ft18NB-NTC-4.5M 15ft18NB-NTC-6.0M 20ft

SST 3.0" x ¼" Molded / Potted Probe30SS-NTC-x.xM Lengths noted above, max length 300ft.Other lengths, NPT Fittings and Thermo-wells available.

Pipe Mount Condenser Molded Probe

PMT6-67-1.5M 5ft. 1/8" to 11/8" Pipe PT-1000

NT6-67-1.5M 5ft. 1/8" to 11/8" Pipe NTC

XH10P 30-90%RH +/- 5% 4…20mA

XH20P 0-99%RH +/- 3% 4…20mA

wall mount

PRESSURE TRANSDUCERS

PP11 0-160psi +/- 1% 4….20mA

PP30 0-435psi +/- 1% 4….20mA

7/16"-20 male

PPR15 0-218psi +/- 1.2% 0/5V

PPR30 0-435psi +/- 1.2% 0/5V

7/16"-20 female

W528-150 0-150psi +/- 1.5% 0/5V

W528-500 0-500psi +/- 1.5% 0/5V

7/16"-20 female

Nickel Plated Brass

Probes

Optional - XH10P

Humidity Probe

Page 11: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

11

XW Walk-in Series

The Dixell XW60K Walk-in controller provides an electronic solution for both medium temper-

ature and low temperature Walk-in units. The XW60K features On-Demand® Defrost, Energy

Saver Mode, Hands Free auto-off lights, Fan Cycling, Remote Keypad, and includes digital

inputs for door ajar switches and other interfaces. Alarms include High and Low temps, door

and condenser alarms. Energy Savings can be up to 20-25%.

XW Superheat Controller

SPECIFICATIONS:Power: 120V / 230Vac 50/60hzOutput: 16FLA /96LRA

2 x 16A1 x 10A

Inputs: NTC / PTCRange: -40 /230 or -58 /302°F PTCDisplay: 3 DigitsIcons: 8 Panel Mount: 32 x 74MMConnections: Probe screw terminalsOutputs: 1/4” fast-onKeyPad: J-Box mount / IP65Communications: TTL Modbus

Approvals:

MODEL RC

Medium Low Temp Refrigeration for Walk-insComp/ Def/ Fan/ Light

The Dixell XW Superheat controller provides an electronic solution for stepper electricexpansion valves. Featuring Pre-sets for all popular valves the XEV22 takes a 0/5V or 4...20mApressure input plus a Pt1000 or NTC input to manage Superheat. Special Defrost algorithmreduces defrost time. Add to the XW60K for an Advanced Walk-in Control solution.

Ratio-Metric Transducer

Page 12: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

12

Advanced ControlsFEATURES

• Redundant System Control • Normal Lead/Lag or Multi System• Back Lit LCD Display• Configurable Change over from one

hour to twenty-one days• Compressor (Liq. line solenoid)• Defrost• Fan Control• Alarm Auto Switch Over • Alarm Dry Contact output• Multi-Probe Control• Energy Saving Cycles• Real Time Clock• Door Switch Input• Gas Leak Detector Input• Condenser Alarm• Anti-Short Cycling• Security Keyboard Locking• Ethernet Connection• RS-485 ModBus

Lead/Lag Controller

DX-Touch

The DX-Touch HMI includes the following features:

• 4.3" Touch screen, “Smart Device” HMI• Connect to Any Dixell Prime Series Control via RS-485• Auto Configure• Email, SMS, FTP, VNC and Web functionality • View/Control using PC, Tablet or Smartphone• Alarm monitoring and alarm history• Data logging and historical data viewer• 4 level security levels• Digitally signed audit trails and data files• National time server with daylight savings• Multi-lingual supports over 25 languages• 30,000 hour LED display

VisoGraph LCD display

iPro Genius PLC

RS485

Page 13: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

13

XWEB300D/500D

The Dixell XWEB300D is a web server that is connected to Dixell probe acquisition modulesand/or Dixell digital controllers for a distributed control system. Devices connect via anRS485 network or Wireless options. The data collected from the HVAC/R systems can beviewed and remotely controlled online. Additionally, the Dixell XWEB allows for SMSalarms to be sent in the event an alarm is triggered via email.Two features found in the Dixell XWEB500D are the scheduler and layout view. The schedulingfeature allows for the devices to be set into energy savings mode or turned off at a pre-programmed time. The layout view offers the customer the option to incorporate a floorplan of the facility with the locations of the equipment showing their operating conditions.The Dixell XWEB300D and XWEB500D do not require any additional software and thereare no fees associated with using the monitoring/controlling web site. Scalable andeconomical, the XWEB System can manage Energy usage, collect and store importantFood Safety data.

APPLICATIONS FOR FOOD SAFETY AND ENERGY SAVINGSCHOOLS • FOOD WAREHOUSES • INSTITUTIONAL FOOD SERVICE • C-STORES

HOTEL KITCHENS • FOOD PROCESS • RESTAURANTS • SUPERMARKETS

Dixell Monitoring & Control Applications via the Internet

XWEB500 INTERNET CONTROL & MONITORING FOR HACCP AND ENERGY SAVINGS

XJR40D Relay Module• Lighting• Security

XJR60D Monitor Module•Temperature/HACCP• Pressure

iCool900 Wireless120 Vac /5Vdc

iStat/Pro2 Heat2 Cool

Heat Pump

XWeb500 Connect to the Internet

XW60KWalk-in’s w/

On-Demand®Defrost

XR70CK Refrigeration ControllerReach-ins

Page 14: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

14

Home Page Network Connections

Graphs Run Time Screen

Page 15: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

15

Layout View Scheduler Screen

Alarm History Parameter Settings

XJP60D i/o Module

Monitor: Temperature, Pressure,

%RH, 4...20mAInputs: 6 NTC/PTC + 3 Digital Inputs

Output: RS485 Modbus

Power: 24Vac

XJR40D Relay Module

Control Lights / LoadsInputs: 4 Digital Inputs

Outputs: 4 x SPDT 8A relays

RS485 ModbusPower: 24Vac

iStat/ProTouch Screen Universal Thermostat2 stage Heat / 2 Stage Cool / Heat Pump / Remote SensorOutput: RS485 Modbus

Power: 24Vac

XH55PAntiSweat Dew Point ControllerKit includes 16A SSR (up to 5)Output: 8A Relay, 4...20mA analog out

RS485 Modbus

Power: 24Vac

WM14 Power Analzer

A, V, Hz, KWhr, Phase, etc.Requires external CT (Current Transformers)Power: 90-260Vac

Output: 5A relay, RS485 Modbus

iCooll 900 Wireless

1500 ft to 8 mile range (w/ outdoor antennae)Power: 120V transformer included

iCooll 2.4 Wireless

500 ft rangePower: 24Vac

Page 16: Monitoring and Controls - Weiss Instrumentsweissinstruments.com/pdf/Dixell_Catalog.pdf ·  · 2014-05-01Project specifications may ... of the suction and discharging lines by using

905 WAVERLY AVE.HOLTSVILLE, NEW YORK 11742631-207-1200 FAX: 631.207.0900www.weissinstruments.com

PRODUCTSProfessional HACCP Monitoring Dixell Controls for Food ServiceHVAC Thermostats Lighting Controls Energy MonitoringData Logging Alarms Digital Thermometers

FOOD SAFETY & ENERGY SAVING APPLICATIONSSchools Food Warehouses Institutional Food Service C-Stores Hotel Kitchens Food Process Restaurants Supermarkets

MC