CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog 12-21 January 2001 Molded Case Circuit Breakers 12 10 – 225 Amperes F-Frame Vol. 1, Ref. No. [0487] Product Selection Table 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Note: Instruction Leaflet/FRED Number 29C101 Table 12-34. Type EHD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units 1 Not UL listed. 5 kAIC interrupting rating. 2 UL listed for SWD applications, see NEC Article 240-83 (d). Note: Instruction Leaflet/FRED Number 29C101 Maximum Continuous Ampere Rating @ 40°C 240V AC Maximum, 125V DC (Includes Terminals on Load End Only) 65 kAIC @ 240V AC 100 kAIC @ 240V AC 200 kAIC @ 240V AC Type ED Type EDH Type EDC Current Limiting 2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ 100 125 150 175 200 225 ED2100 ED2125 ED2150 ED2175 ED2200 ED2225 357. 357. 357. 357. 357. 357. ED3100 ED3125 ED3150 ED3175 ED3200 ED3225 885. 885. 885. 885. 885. 885. EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 850. 850. 850. 850. 850. 850. EDH3100 EDH3125 EDH3150 EDH3175 EDH3200 EDH3225 1,280. 1,280. 1,280. 1,280. 1,280. 1,280. EDC2100 EDC2125 EDC2150 EDC2175 EDC2200 EDC2225 1,200. 1,200. 1,200. 1,200. 1,200. 1,200. EDC3100 EDC3125 EDC3150 EDC3175 EDC3200 EDC3225 1,655. 1,655. 1,655. 1,655. 1,655. 1,655. Maximum Continuous Ampere Rating @ 40°C 277V AC Maximum, 125V DC 480V AC Maximum, 250V DC 14 kAIC @ 277V AC 14 kAIC @ 480V AC Type EHD (Includes Terminals on Load End Only) 1-Pole 2-Pole 3-Pole Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ 10 1 15 20 25 30 35 40 45 50 60 70 80 90 100 EHD1010 EHD1015 2 EHD1020 2 EHD1025 EHD1030 EHD1035 EHD1040 EHD1045 EHD1050 EHD1060 EHD1070 EHD1080 EHD1090 EHD1100 123. 123. 123. 123. 123. 123. 123. 123. 123. 123. 238. 239. 238. 238. EHD2010 EHD2015 EHD2020 EHD2025 EHD2030 EHD2035 EHD2040 EHD2045 EHD2050 EHD2060 EHD2070 EHD2080 EHD2090 EHD2100 387. 387. 387. 387. 387. 387. 387. 387. 387. 387. 505. 505. 505. 505. EHD3010 EHD3015 EHD3020 EHD3025 EHD3030 EHD3035 EHD3040 EHD3045 EHD3050 EHD3060 EHD3070 EHD3080 EHD3090 EHD3100 498. 498. 498. 498. 498. 498. 498. 498. 498. 498. 600. 600. 600. 600. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2

Molded Case Circuit Breakers 12-21 10 – 225 Amperes...CAT.200.01.T.E For more information contact Cutler-Hammer at: 12-21 January 2001 Molded Case Circuit Breakers 12 10 – 225

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

    12-21January 2001

    Molded Case Circuit Breakers

    12

    10 – 225 AmperesF-Frame

    Vol. 1, Ref. No. [0487]

    Product SelectionTable 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed

    Note: Instruction Leaflet/FRED Number 29C101

    Table 12-34. Type EHD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

    1 Not UL listed. 5 kAIC interrupting rating.2 UL listed for SWD applications, see NEC Article 240-83 (d).

    Note: Instruction Leaflet/FRED Number 29C101

    MaximumContinuousAmpereRating@ 40°C

    240V AC Maximum, 125V DC (Includes Terminals on Load End Only)

    65 kAIC @ 240V AC 100 kAIC @ 240V AC 200 kAIC @ 240V AC

    Type ED Type EDH Type EDC Current Limiting

    2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    100125150175200225

    ED2100ED2125ED2150ED2175ED2200ED2225

    357.357.357.357.357.357.

    ED3100ED3125ED3150ED3175ED3200ED3225

    885.885.885.885.885.885.

    EDH2100EDH2125EDH2150EDH2175EDH2200EDH2225

    850.850.850.850.850.850.

    EDH3100EDH3125EDH3150EDH3175EDH3200EDH3225

    1,280.1,280.1,280.1,280.1,280.1,280.

    EDC2100EDC2125EDC2150EDC2175EDC2200EDC2225

    1,200.1,200.1,200.1,200.1,200.1,200.

    EDC3100EDC3125EDC3150EDC3175EDC3200EDC3225

    1,655.1,655.1,655.1,655.1,655.1,655.

    MaximumContinuousAmpere Rating@ 40°C

    277V AC Maximum, 125V DC 480V AC Maximum, 250V DC

    14 kAIC @ 277V AC 14 kAIC @ 480V AC

    Type EHD (Includes Terminals on Load End Only)

    1-Pole 2-Pole 3-Pole

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    Catalog Number

    PriceU.S. $

    10 1 15 20 25 30 35 40 45 50 60 70 80 90100

    EHD1010EHD1015 2EHD1020 2EHD1025EHD1030EHD1035EHD1040EHD1045EHD1050EHD1060EHD1070EHD1080EHD1090EHD1100

    123.123.123.123.123.123.123.123.123.123.238.239.238.238.

    EHD2010EHD2015EHD2020EHD2025EHD2030EHD2035EHD2040EHD2045EHD2050EHD2060EHD2070EHD2080EHD2090EHD2100

    387.387.387.387.387.387.387.387.387.387.505.505.505.505.

    EHD3010EHD3015EHD3020EHD3025EHD3030EHD3035EHD3040EHD3045EHD3050EHD3060EHD3070EHD3080EHD3090EHD3100

    498.498.498.498.498.498.498.498.498.498.600.600.600.600.

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2

    TAB1201.fm Page 21 Wednesday, October 25, 2000 9:37 PM

  • 12-20

    For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

    January 2001

    Molded Case Circuit Breakers

    12

    10 – 225 AmperesF-Frame

    Vol. 1, Ref. No. [0486]

    Dimensions/WeightsTable 12-30. Dimensions in Inches (mm) Table 12-31. Approximate Shipping Weight, Lbs. (Kg)

    Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbers for circuit breakers or trip units.

    Table 12-32. Circuit Breaker Catalog Numbering System

    Number of Poles

    Width Height Depth

    12

    1.375 (35)2.75 (70)

    6 (152)6 (152)

    3.375 (86)3.375 (86)

    34

    4.125 (105)5.5 (140)

    6 (152)6 (152)

    3.375 (86)3.375 (86)

    Breaker Type Number of Poles

    1 2 3 4

    ED, EDH, EDC — 3 (1.361) 4.5 (2.041) —

    EHD, FDB, FD, HFD, FDC 2 (.907) 3 (1.361) 4.5 (2.041) 6 (2.721)

    Circuit Breaker Type

    EHDFDBFDHFDFDC

    Number of Poles

    1 = 1 Pole2 = 2 Poles3 = 3 Poles4 = 4 Poles

    Trip Amperes

    010015020025030035040045050060070080090100110125150175 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)200 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)225 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)

    Suffix

    E = 100% Protected (4-Pole only) Neutral PoleEH = 50% Protected (4-Pole only)K = High Magnetic Molded Case SwitchL = Line and Load TerminalsS = Stainless Steel TerminalsV = 50°C CalibrationW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (≤ 100 Amperes)

    F D C 3 1 0 0 L

    E D C 3 2 0 0 L

    Circuit Breaker Type

    EDEDHEDC

    Number of Poles

    2 = 2-Pole3 = 3-Pole

    Trip Amperes

    100125150175200225

    Suffix

    L = Line and Load TerminalsW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (100 Amperes)

    TAB1201.fm Page 20 Wednesday, October 25, 2000 9:37 PM

  • CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

    12-19January 2001

    Molded Case Circuit Breakers

    12

    10 – 225 AmperesF-Frame

    Vol. 1, Ref. No. [0485]

    ContentsDescription Page

    Product Description . . . . . . . . 12-19Technical Data

    and Specifications . . . . . . . . 12-19Dimension/Weights . . . . . . . . 12-20Product Selection . . . . . . . . . . 12-20

    F-Frame

    Typical F-Frame Breaker

    Product Description■ All F-Frame Circuit Breakers are

    HACR rated.■ All circuit breakers 10 through

    50 amperes are suitable for HID (high intensity discharge) use.

    ■ All F-Frame circuit breakers are suitable for reverse feed use.

    Technical Data and SpecificationsTable 12-28. UL489 Interrupting Capacity Ratings

    1 DC ratings apply to substantially non-inductive circuits.2 2-pole circuit breaker, or two poles of 3-pole circuit breaker.3 Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

    Table 12-29. IEC 157-1 (P1) Interrupting Capacity Ratings (P1)

    4 DC ratings apply to substantially non-inductive circuits.5 2-pole circuit breaker, or two poles of 3-pole circuit breaker.6 Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

    Circuit Breaker Type

    Number of Poles

    Interrupting Capacity (Symmetrical Amperes) (kA)

    Volts AC (50/60 Hz) Volts DC 1

    240 277 480 600 125 250 23

    ED EDH EDC

    2, 3 2, 3 2, 3

    65 100200

    ———

    ———

    ———

    101010

    ———

    EHD 12, 3

    —18

    14—

    —14

    ——

    10—

    —10

    FDB 2, 3, 4 18 — 14 14 — 10

    FD 12, 3, 4

    —65

    25—

    —25

    —18

    10—

    —10

    HFD 12, 3, 4

    —100

    65—

    —65

    —25

    10—

    —22

    FDC 2, 3, 4 200 — 100 35 — 22

    Circuit Breaker Type

    Number of Poles

    Interrupting Capacity (Symmetrical Amperes) (kA)

    Volts AC (50/60 Hz) Volts DC 4

    220, 240 380, 415 440 500 125 250 56

    ED EDH EDC

    2, 32, 32, 3

    65100200

    ———

    ———

    ———

    101010

    ———

    FDB 2, 3, 4 18 14 14 14 — 10

    FD 12, 3, 4

    25 65

    —35

    —35

    —18

    10—

    —10

    HFD 12, 3, 4

    65 100

    —65

    —65

    —25

    10—

    —22

    FDC 2, 3, 4 200 100 100 35 — 22

    TAB1201.fm Page 19 Wednesday, October 25, 2000 9:37 PM

    Back To Welcome2: ContentsD: Contents: