Upload
ginger-logan
View
222
Download
0
Tags:
Embed Size (px)
Citation preview
Moeller GmbHpage - 1
ATEX
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 2
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
What is ATEX, and what does it stand for?
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 3
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
ATmosphères EXplosibles=
potentially explosive atmospheres!
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 4
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
There are two kinds of potentially explosive atmospheres!
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 5
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
There are two kinds of potentially explosive atmospheres!
1) gas
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 6
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
There are two kinds of potentially explosive atmospheres!
1) gas2) dust
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 7
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
In this case we are talking solely about use in dusty atmoshere!
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 8
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
In addition there are also two different ATEX directives!
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 9
Refer to protection notice IS
O 16016
ATEX – HMI-PLC
Introduction
In addition there are also two different ATEX directives!
Directive for Operators: 1999/92/EC (mandatory from 06/2006)
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 10
Refer to protection notice IS
O 16016
ATEX – HMI-PLC
Introduction
In addition there are also two different ATEX directives!
Directive for Operators: 1999/92/EC (mandatory from 06/2006)
Directive for Manufacturers: 94/9/EC (mandatory since 06/2003)
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 11
Refer to protection notice IS
O 16016
ATEX – HMI-PLC
Introduction
In this case we are talking soley about thedirective 94/9/EC (mandatory since 06/2003)
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 12
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction
What is the difference between these two ATEX directives?
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 13
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction: ManufacturerEquipment and protective systems in potentially explosive atmospheres!
1) Divided in to equipment groups: Group Operational Area I Mining Industry II all areas, except Mining Industry
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 14
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction: ManufacturerEquipment and protective systems in potentially explosive atmospheres!
1) Divided in to equipment groups Group Operational Area I Mining Industry II all areas, except Mining Industry 2) Divided in to Categories Group Category Safety I M 1 very high I M 2 high II 1 very high II 2 high II standard
33
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 15
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction: OperatorOperating in potentially explosive atmospheres!
1) Assessment of risc of explosion, producing a zone plan, documentation, etc. gas/fog dust risk of explosion Zone 0 Zone 20 always, often, long-run Zone 1 Zone 21 occasional Zone 2 Zone 22 usually not
if so, only short-run
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 16
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction: OperatorOperating in potentially explosive atmospheres!
1) Assessment of risc of explosion, producing a zone plan, documentation, etc. gas/fog dust risk of explosion Zone 0 Zone 20 always, often, long-run Zone 1 Zone 21 occasional Zone 2 Zone 22 usually not
if so, only short-run
2) Choise of equipment and protectionism by categories gas/fog dust Category Zone 0,1,2 Zone 20,21,22 1 Zone 1,2 Zone 21,22 1, 2 Zone 2 Zone 22 1, 2 33
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 17
Refer to protection notice IS
O 16016
Introduction: Operator Operating in potentially explosive atmospheres!
Zone 20 = Category 1Zone 20 = Category 1
Zone 21 = Category 1 and 2Zone 21 = Category 1 and 2
Zone 22 = Category 1, 2 andZone 22 = Category 1, 2 and
ATEX - HMI-PLC
33
INFO >> http://europa.eu.int/comm/enterprise/atex/otherinfo.htmINFO >> http://europa.eu.int/comm/enterprise/atex/otherinfo.htm
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 18
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
Introduction: summary
Directive 94/9/EC by the European Parliament and the Council of 23 March 1994
Directive 94/9/EC of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres.
http://europa.eu.int/comm/enterprise/atex/direct/newapproach.htm
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 19
Refer to protection notice IS
O 16016
ATEX - HMI-PLC
technical requirements : EN 50281-1-1
section 8: test (extract)
Table 3 contains applications and requirements according EN 50014 for „Electrical apparatus for potentially explosive atmospheres”
example:- mechanical tests- thermical tests- thermical shock tests- responsibility- documentation
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 20
Refer to protection notice IS
O 16016
ATEX – HMI-PLC
Namen und FirmenadresseNamen und Firmenadresse
Type XVC-601-GTI-10-V1-000TypeNo 272547Supply 24VDC 1.1A
*0404400009* KW 18/04
Type XVC-601-GTI-10-V1-000TypeNo 272547Supply 24VDC 1.1A
*0404400009* KW 18/04
technical requirements: EN 50281-1-1
section 12: identificiation
Certification Mark: II 3 DDegree of Protection: IP65 Temperature class: T0-50°C
Certification Mark: II 3 DDegree of Protection: IP65 Temperature class: T0-50°C
Name and address of companyProduktion Code
Name and address of companyProduktion Code
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 21
Refer to protection notice IS
O 16016
ATEX – HMI-PLC
Application:
- Milling Industry- Grinding Industry- Timber Processing- Cementation- Aluminium Industry- Manufacturer of Animal Feeds- Pharmazie
generally information
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 22
Refer to protection notice IS
O 16016
generally informationATEX productrange of potentially dustexplosive atmospheres!
Productrange Zone 20 Zone 21 Zone 22HMI-PLCXVC-601-GTI(R)-... no no available since 06/2004XCC-601-DVI-... no no available since 06/2004XV-DVI-GTI(R)- ... no no available since 06/2004
HMI / HMI-PLCXV-4x2-57CQB-x-xx no no available since 03/2005XV-4x0-10TVB-x-xx(50)* no no available since 03/2005XV-4x0-12TVB-x-xx(50)* no no available since 03/2005
HMIXVH-3xx-57xxx-x-xx no no available since 03/2005
* IR-Touch, Satin-finish brushed stainless steel
ATEX – HMI-PLC
IB A
TE
X 2005-04-G
B
Moeller GmbHPage - 23
Refer to protection notice IS
O 16016
Think future. Switch to green
END: Thank you