12
UK Distributor Modular Pre Hospital Defibrillation Modular | Lightweight | Live Telemedicine | Advanced Battery Technology

Modular Pre Hospital Defibrillation - Home - The … | The solution: corpuls.web In the browser-based applicationcorpuls.web, medical data collected with thecorpuls3 by the ambulance

  • Upload
    hahanh

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

UK Distributor

Modular Pre Hospital Defibrillation

Modular | Lightweight | Live Telemedicine | Advanced Battery Technology

| 02

With many years experience in the EmergencyService Sector, our high calibre management teamwill provide you with the commitment andprofessionalism required to form a longwithstanding relationship.

Vision Statement

To supply leading edge, technology products formission critical vehicle systems.

What is Ortus

Ortus was formed to harness and capitalise on theskills and industry knowledge of its team members inorder to provide a highly specialised distributionbusiness supplying vehicle based technology solutions.

Ortus Strategy

Ortus has positioned itself as the industry leader insourcing and providing technology solutions for theEmergency Services and Mission Critical VehicleMarkets.

We continue to secure agreements with entrantsseeking partnership arrangements for their UK andEuropean sales strategies in this market sector.

About Ortus

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

03 |

The corpuls3 offers an entirely new and revolutionarydesign concept compared with traditionaldefibrillator/monitoring devices.

It is designed as a complete modular system and canbe split into:

Monitoring unit

Patient box

Defibrillator/Pacer unit

This means unrivalled ergonomics, functionality and flexibility.

Wireless Communication

The unique wireless network-technology allowsoperation of the components independently as if theywere physically connected.

corpuls3

Are you ready for the future?

0845 459 5705 | [email protected] | www.ortus.co.uk

Highlights

• *Total weight of compact unit only 6.3 kg

• The constant and immediate feedback of corPatch CPR ensures high quality CPR

• Intuitive user interface enables fast diagnosis

• Uninterruptible monitoring from the EMS site into the hospital

• Large 8.4” colour display with individually configurable display views

• Usage under extreme conditions possible (IP55, operating temperature -20° to +55°C)

• Advanced energy management

• Tested mounting solutions for everyscenario available

*basic configuration

UK Distributor

| 08

Workflow corpuls.web

Security features of corpuls.web

• Separate transmission of patient data (static) and medical data (dynamic) to server

• Encryption of patient data when transmitted (128-Bit AES encryption)

• Verified SSL certificate for transmission from server to client

• Highest security standards by the server hoster (ISO 27001)

• Server reliability 99,5% (extendable)

SIM card slot for integratedGSM modem

LAN interface

Static Data• 12 lead diagnostic ECG • Events/Alarms• Patient data • Master data

Dynamic Data• Curves• Vital parameters

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

09 |

Forwarding destinations

- E-Mail address

- (S)FTP server directories per upload

- Network drive directories

- Fax end device (optional)

PDF SCP DICOM *)HL7/aECG *)

DatamedECG-converter **)

Requirements for the client

Support Web-Browsers • Mozilla Firefox

• Windows Internet Explorer

• Google Chrome

• Apple Safari

Minimum Hardware Requirements • 1 GHz processor

• 1 GB RAM (32 -Bit),2 GB RAM (64-Bit)

• Screen resolution min.1280 x 800 pixels (recommended: 1600 x 900 pixels)

Notification via

• E-Mail

• SMS *)

• Pager *)

• Automated calls *) Browser basedapplication

Manual forwarding of 12lead diagnostics ECG

Automatic forwarding of 12 lead diagnostic ECG(configurable with forwarding rules)

*) Will be available in the future **) For further information: www.datamed.com

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

| 06

Why Telemedicine?

Medical studies in the last few years have shown that aquick and professional treatment of the patient alreadyin the pre-hospital field significantly increases thesurvival rate. Additionally, the increasing cost pressure inthe health care system demands innovative and cost-cutting solutions not only from EMS providers, but alsofrom manufacturers of medical technology.

Telemedicine connects established telecommunicationtechnologies and medical technology in a way that only afew years ago was not yet possible technically.Nowadays, thanks to telemedicine, the hospital staff canprepare early on before the patient arrives.

Advantages of telemedicinewith corpuls.web

• Utilisation of the browser-based application on every end device

• Clever management of resources by early therapy recommendation and treatment

• Live data transmission of curves and parameters• Display, measurement and forwarding

of the 12 lead diagnostic ECG in various formats(e.g. PDF, SCP)

• Approved Medical Product

Referral without delay:Managing short resources

The advisory support on-site and the intra-hospitalpreparation optimises patient care.The early transmission of patient data from the scenegives the specialist in the hospital enough time andinformation to optimally prepare for the arriving patient. The permanent storage of the transmitted data supportsthe exacting requirements of quality management inemergency care.

30% time saved

By using telemedicine in the pre-hospital care, the door-to-balloon time is reducedsignificantly. [1]

[1] Rao A et al. (2010 Feb): Impact of the prehospital ECG on door-to-balloon time in ST elevation myocardial infarction. Providence Hospital and Southfield, USA

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

07 |

The solution:corpuls.web

In the browser-based application corpuls.web,medical data collected with the corpuls3 by theambulance crew on-site are transmitted live tospecialists in the hospital. Without delay, a treatmentrecommendation can be offered and the treatment ofthe patient can start immediately.

The corpuls3 transmits all vital parameters and curvesas well as the 12 lead diagnostic ECG live tocorpuls.web. This application can be run on everyweb-enabled device.

Emergency Site Data Reception Recommendation/Therapy

Strategies to reduce the door-to-balloon time in myocardial ischaemias [2]

Application options Time gain Solutions with corpuls.web

Already on-site, the ambulance crew can supply the PCI lab with relevant data.

Reception and visualisation of the 12 leaddiognostic ECG.

Up to24 min.

Up to13 min.

There is a data exchange in realtime betweenthe ambulance crew and the hospital.

Continuous transmission of live data and of the12 lead diagnostic ECG already during transport.

4

4

[2] Bradley EH et al. (2006 Nov): Strategies for reducing the door-to-balloon time in acute myocardial infarction. Yale University School of Medicine, New Haven, USA

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

| 04

0845 459 5705 | [email protected] | www.ortus.co.uk

Monitoring unit

The detachable Monitoring unit guarantees easy handlingand provides an ergonomic solution for pre hospitalsituations.

• Jog-dial, softkeys and function keys for intuitive, fast and immediate access and operation

• Large colour display (8,4”) with individually configurable display views and 12 lead diagnostic ECG preview

• Integrated LAN or GSM for data transmission withcorpuls.web

Patient box

The Patient box is the “heart” of the system and enablesuninterruptible monitoring from the EMS site into thehospital.

• The immediate feedback on depth and rate of thorax compressions of corPatch CPR ensures high quality CPR and improves the outcome of patients

• Simultaneous 12 lead diagnostic ECG with optional measuring and interpretation software

• Innovative Masimo® Rainbow® SET technology for measurement of SpO2, SpCO, SpMet, SpHb, PI and PP

Defibrillator/Pacer unit

Greater mobility and flexibility due to weight reduction ifthe defibrillator is not needed.

• Enhanced therapy options with smart metronome during CPR

• Pacing: fix, demand and overdrive pacing with ramp-down mode

• Optional usage, with corPatch therapy electrodes or shock spoons

corpuls3

UK Distributor

05 |

0845 459 5705 | [email protected] | www.ortus.co.uk

General Specifications:

• Dust and splash-proof (IP55)• Vibration- and shockproof according to DIN EN 1789• MIL STD 810 G - Categories 4, 9

(US Military Standard)• RTCA DO 160 F - Sections: 4, 5, 6, 20, 21, 25 (aircraft

approved)• Li-Ion Battery (3 batteries, identical in construction)• Power supply 12 V DC, 100 – 250 V AC with mains

adapter• Dimensions compact device (HxWxD): 29.6 cm x

30.5 cm x 19.5 cm

Monitoring unit

• 8.4’’ colour display, transflective, backlit

• 6 traces/13 vitalparameters

• All-around impact protection

• Printer: paper width 106 mm, paper length 22 m

• Weight: 2.7 kg

• Dimensions (HxWxD): 29.5 cm x 30.5 cm x 12 cm

Patient box

• corPatch CPR

• 12 lead ECG, HR, BR, NIBP, 4xIBP, 2xTEMP, CO2, SpO2, SpCO, SpMet, SpHb, PI, PP

• CompactFlash® storage

• Acoustic alarm; microphone for voice recording

• Accessory bag for cables and sensors

• Weight: 1 - 1.3 kg

• Dimensions (HxWxD): 13.5 cm x 26.5 cm x 5.5 cm

Defibrillator/Pacer unit

• Biphasic, rectangular waveform, full impedance compensation

• AED protocol according to AHA/ERC 2010 Guidelines

• 2 to 200 Joules, configurable energy protocol, 1-2-3

• smartMetronome

• Weight: 2.3 kg (basic configuration)Size (HxWxD): 22 cm x 28 cm x 12 cm

UK Distributor

| 10

12 lead diagnostic ECG/Livestreaming

12 lead ECG diagnosis

Livestreaming

Editing the patient – andmaster data in the mission

Display of curves and vital parameterstransmitted in realtime from theCorpuls3

corpuls

.web Server

Hospita

l

Smartphone/TabletPC

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

11 |

Scope of functionsCorpuls.web

Mission List• Configurable mission list for

displaying new and already reviewed missions

Mission• Displaying and editing of patient-

and master data of the Corpuls3

12 lead diagnostic ECG• Display of the 12 lead preview of

the diagnostic ECG

• Selection of the lead to be measured

• Manual 2-point measurement of a lead

• Display of the measurement table generated by the software module HES

• Export as PDF or SCP

Live data• Realtime display of curves and

parameters transmitted from the Corpuls3

Events• Display of all technical and

physiological events and alarms recorded by the Corpuls3

Report• Documentation of :

- Medical history- Diagnosis- Therapy recommendation

Preview of all 12 leads of the diagnostic ECGincluding the vitalparameters

Display of all technical andphysio-logical events andalarms recorded by theCorpuls3

Measurement of a selected leadof the 12 lead diagnostic ECG viaamplitude and duration

Documentation of medicalhistory, diagnosis and therapyrecommendations

0845 459 5705 | [email protected] | www.ortus.co.uk

UK Distributor

Ortus Medical

The Turbine, Shireoaks Triangle Business ParkCoach Close, Worksop S81 8AP

t: 0845 459 5705 f: 0845 459 4706 e: [email protected]

www.ortus.co.uk G R O U P

Ortus Medical is a trading name ofOrtus Technology Limited and is partof the Ortus Group