Includes information on the latest updates and revisions to the
Modular Lube Line including the new MC2-HP high-pressure divider valves
MODULAR LUBE ®AUTOMATED LUBRICATIONSYSTEMS
MODULAR LUBE ®AUTOMATED LUBRICATIONSYSTEMS
MODULAR LUBE ® AUTOMATED LUBRICATIONSYSTEMS
We’re the largest and most successful company in our fieldbecause we continually satisfy ourcustomers with the world’s bestlubrication and pumping systems.For almost 90 years, companieshave relied on our technical andquality leadership, our world-classmanufacturing and customer service and our vast network of distributors and support facilities.
Lincoln develops new products and systems at research and development facilities in the UnitedStates, Germany and India that provide global and regional application solutions.
We have solutions for large processing plants, automotivemanufacturing, pulp and papermills and food and beverage facilities. Virtually every industrial professionalinvolved in operations and maintenance canbenefit from Lincoln systems.
On the road or in the field, Lincoln protectsheavy equipment used in mining, construc-tion, agriculture and over-the-road trucking.The world’s leading manufacturers offer oursystems as standard equipment or factoryoptions.
Lincoln builds precision metal components,state-of-the-art electronic controlsand the industry’s top-performingpump systems. Our quality systemsin the United States and Germanyare ISO 9001 registered.
With five technical support centers on three continents and a network of system houses and distributors supported by regionalsales and service offices, our customers can always draw on our worldwide resources.
To make sure your investmentresults in significant savings,Lincoln developed a unique program called BearingSaver®. You not only get a complete audit of your facility, but you alsoreceive 0an analysis of your return on investment.
People, Capabilities and Systems to Save Money and Increase Productivity
Worldwide Support
Customer Service
Research & Development BearingSaver®
Mobile Equipment
QualityManufacturing
IndustrialSolutions
Modular Lube® Lubrication SystemsTable of Contents
1
Introduction to Modular Lube® . . . . . . . . . . . . . . . . . . . . . . . . 2
UV Divider Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
MC2-HP Divider Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
XL Divider Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
UV, XL and MC2-HP Divider Valve Accessories . . . . . . . . . . . 7
Divider Valve Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Introduction to Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pneumatic Modular Pumps . . . . . . . . . . . . . . . . . . . . . . . . . 12
Hydraulic Modular Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Baseplates and Reservoirs. . . . . . . . . . . . . . . . . . . . . . . . . . 13
Modular Pump Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 14
Modular LP Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Reciprocating Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
FlowMaster® Hydraulic Pump . . . . . . . . . . . . . . . . . . . . . . . . 17
MCLP Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Pump Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Pump to Point Lubricators . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Pump to Point Lubricator Accessories . . . . . . . . . . . . . . . . 25
System Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Modular Lube® Lubrication SystemsIntroduction to Modular Lube
2
UV, XL SeriesDesigned for standard industrial applications. UV and XL Modular Lube systems are fully automatic, centralized lubrication systems for use on all types of industrial machinery.
Type UV and XL are available in several divider valvesizes and outputs, and provides maximum flexibility inapplication. This is the most versatile of the Modular Lubesystems. It can be installed on all machine tools (metal-cutting, metal forming), foundry machinery, wood-workingand wood processing equipment, printing machinery, mining equipment and material handling machinery.
MC2-HP Series (High Pressure)Designed for gas engine and compressor lubrication systems. MC2-HP series systems are designed for the gas transmission industry and are available with Viton®
seals. The divider valves are compatible with either synthetic or petroleum-based lubricants. High-pressurecapability to overcome back pressure with CSA-approvedmonitoring components available.
Built-in design optionsWhen new technology calls for design alterations, the system designer can add or delete lubrication points without disturbing existing piping.
It’s an economical systemLincoln’s Modular Lube single-line progressive system requires less piping and lower tubing costs at installation—andcosts less to maintain or change when the need arises.
Patented by-pass blockThis unique feature enables design engineers to extend any Lincoln Modular Lube system simply by removing the by-pass block and replacing it with a metering valve. When new machine accessories are added, Modular Lube stands ready to service any bearing point requirements.
Central SignalingIf a malfunction should occur due to a broken air line, low lubricant level, high pressure or line blockage, Lincoln’sModular Lube automatic lube system controls can be configured to signal the operator with a visual or audible alarm, and interlock contacts activate a machine shut-down circuit.
Plug-in conceptThe Lincoln modular concept allows faster and easier changing of metering valve sizes. Modular pumps, reservoirs and timers make up a compact easy-to-mount lube system, simplifying the work of system designers and maintenance engineers.
Versatile interchangeable componentsDivider valves, pumps reservoirs and controls can be used to tailor a Lincoln Modular Lube system to suit individualneeds and/or requirements. Inventory costs are reduced to a minimum by purchasing modular components.
You’re assured of positive stallIf a lubricating line plugs, any progressive lube system should shut down entirely—that’s what it’s designed to do.However, when a feed line becomes plugged on some systems, system pressure can cause lubrication to gradually slip by a valve piston, allowing the system to resume functioning—with one or more lubricating lines out of operation.Machinery bearings could run dry with disastrous results. Modular Lube has the closest piston-to-valve tolerances in the industry, virtually assuring you a positive stall every time.
a BearingSaver product
Modular Lube® Lubrication SystemsIntroduction to Modular Lube
3
Modular Lube Divider ValvesLincoln divider valve assemblies are comprised of three or more metering valves mounted to a segmented baseplate.The metering valves are available with single or twin outlets and may be externally singled or cross-ported. Extremelyclose tolerances between piston and valve body allow metering valves to deliver precise volumes of lubricant at highoperating pressures.
Illustration 1The inlet passageway is connected to all piston chambers at all times with only one piston free to move at any onetime. With all the pistons at the far right, lubricant from the inlet flows against the right end of piston 1 (top).
Illustration 2Lubricant flow shifts piston 1 from right to left, dispensing lube from outlet 1. The shifting piston 1 directs the lubricant flow against the right side of piston 2 (center).
Illustration 3Lubricant flow shifts piston 2 from right to left, dispensing lube through valve ports of piston 1 and through outlet 2. The shift of piston 2 directs lubricant flow against the right side of piston 3.
Illustration 4Lubricant flow shifts piston 3 (bottom) from right to left, dispensing lube through the valve ports of piston 2 and through outlet 3. The shift of piston 3 directs lubricant through a connecting passage to the left side of piston 1.Lubricant flow against the left side of piston 1 begins the second half-cycle, which shifts pistons from left to right, dispensing lubricant through outlets 4, 5 and 6 of the divider valve.
ApplicationsLincoln Modular Lube systems are popular in metal cutting and machining applications and for lubricating large compressors and other equipment in the oil and gas market.
Many machine makers specify that Modular Lube be installed right at their factory. Customers who have purchased machines without automatic lubrication can have Modular Lube systems retro-fitted in the field.
4
2
3
1
5
6
4
2
3
1
5
6
4
2
3
1
5
6
4
2
3
1
5
6
Modular Lube® Lubrication SystemsDivider Valves
4
Specifications:Max. Lube Max. Inlet Section Intermediate Section Performance Material of Seal
Points/ Oper. Press.Model Thread Model Thread
Indicator Construction ConstructionAssembly psig / bar Port*
16 3500 / 240 87918 ¹⁄₄" NPSF(F) 87919 ¹⁄₈" NPSF(F) ¹⁄₈" NPSF(F) Yellow chromateplated steel Viton
®
Max. No. of No. of End Tie A Dimensions BOutlets Divider Valves Section Rod* in. mm in. mm
6 3 250290 3.58 90.9 4.52 114.88 4 250291 4.5 114.3 5.44 138.210 5 87920 250292 5.42 137.7 6.36 161.512 6 250293 6.34 161.0 7.28 184.914 7 250294 7.27 184.6 8.20 208.316 8 250295 8.19 208.0 9.13 231.9
Single OutletModel Number Lubricant
W/Right OutputDesignation Standard Side Cycle per Outlet
Model Indicator cu. in. cc05S 882051 — .010 .16410S 882101 — .020 .32815S 882151 — .030 .49220S 882201 882203 .040 .65625S 882251 882253 .050 .82030S 882301 882303 .060 .98335S 882351 882353 .070 1.14740S 882401 882403 .080 1.311
UV DividerValves
UV Divider Valves are designed to meter oil or grease in automatic or manual systems installed on all types of industrial machinery. Segmented baseplate assembly contains all inlet and outlet connections. Alternate outlet ports are located on the face of the dividervalve which may be used for installation of performance indicators.
UV Baseplate and Tie Rod Specifications:
* Can also be used as an alternate outlet port.
* Each tie rod model number includes three tie rods and three fastening nuts.Note: Use 68645 closure plug (1⁄8" NPT) to plug non-working outlets.
Twin OutletModel Number Lubricant
W/Right OutputDesignation Standard Side Cycle per Outlet
Indicator cu. in. cc05T 882052 — .005 .08210T 882102 — .010 .16415T 882152 — .015 .24620T 882202 882204 .020 .32825T 882252 882254 .025 .41030T 882302 882304 .030 .49235T 882352 882354 .035 .57440T 882402 882404 .040 .656
Model 882000 UV Bypass Block Optional by-pass block permits addition or deletion of lubrication points without disturbing existing installations. Includes mounting screws and Buna-N seals.
UV Divider Valve Specifications:
MC2-HP Divider Valves
Modular Lube® Lubrication SystemsDivider Valves
5
Specifications:Maximum Maximum Lube Lube Performance Material of Seal
Lube Points/ Operating Press. Inlet Outlet Indicator Port Construction ConstructionAssembly psig / bar
16 7500 / 512 ¹⁄₄" NPTF(F) ¹⁄₈" NPSF(F) ⁵⁄₁₆" - 24 UNF Black chromate Viton®plated steel
Maximum Number Inlet End Tie Rod Intermediate DimensionsNumber of of Divider Section Section (Qty) Section (Qty) A
Outlets Valves in. mm
6 3 236640 (3) 87957 (3) 5.09 1298 4 236641 (3) 87957 (4) 6.00 15210 5 87955 87956 236642 (3) 87957 (5) 6.91 17612 6 236643 (3) 87957 (6) 7.81 19814 7 236644 (3) 87957 (7) 8.72 22116 8 236645 (3) 87957 (8) 9.63 245.
Single OutletModel Number Lubricant
W/Right OutputDesignation Standard Side Cycle per Outlet
Model Indicator cu. in. cc06S 876061 — .012 .19609S 876091 — .018 .29512S 876121 876123 .024 .39318S 876181 876183 .036 .59024S 876241 876243 .048 .787
MC2-HP High Pressure Divider Valves are designed to dispense either petroleum-based or synthetic lubricants in gas engine and compressor lubrication systems. Segmented baseplate assembly contains all inlet and outlet connections. Alternate outlet ports are located on the face of the divider valve which may be used for installation of performance indicators.
MC2-HP Baseplate and Tie Rod Specifications:
MC2-HP Divider Valve Specifications:
* Can also be used as an alternate outlet port.
Note: Use 68645 closure plug (1⁄8" NPT) to plug non-working outlets. Each 87956 end section contains three tie rod nuts
Twin OutletModel Number Lubricant
W/Right OutputDesignation Standard Side Cycle per Outlet
Indicator cu. in. cc06T 876062 — .006 .09809T 876092 — .009 .14712T 876122 876124 .012 .19718T 876182 876184 .018 .29524T 876242 876244 .024 .393
Model 874000 MC2-HP Bypass Block Optional by-pass block permits addition or deletion of lubrication points without disturbing existing installations. Includes mounting screws and Viton® gasket plate.
A
3.38"86mm
1.87"48mm
1.87"48mm
Modular Lube® Lubrication SystemsDivider Valves
6
Specifications:Maximum Maximum Lube Lube Performance Material of Seal
Lube Points/ Operating Press. Inlet Outlet Indicator Port* Construction ConstructionAssembly psig / bar
12 2500 / 172 ³⁄₈" NPTF(F) ¹⁄₄" NPTF(F) ¹⁄₈" NPTF(F) Zinc plated steel Buna-N
Maximum No. DimensionsModel Number of of Divider A
No. Outlets Valves* in. mm
87030-3 6 3 5.34 13687030-4 8 4 6.69 17087030-6 12 6 9.38 238
XL Divider Valves
XL Divider Valves are designed to meter large volumes of oil or grease in manual or automatic lubrication systems for alltypes of industrial machinery. These units can be used in complete XL systems or integrated as a primary divider valveassembly in systems using UV divider valves as secondaries.Solid one piece baseplate contains all inlet and outlet connections. Convenient front located ports on the divider valveare provided for installation of any desired performance indicators.
XL Baseplate Specifications:
XL Divider Valve Specifications:
* Can also be used as an alternate outlet port.
Model 87028 XL Bypass Block Optional by-pass block permits addition or deletion of lubrication points without disturbing existing installations. Includes mounting screws and Viton® O-ring seals.
Single OutletTotal
Standard With Right LubricantDesignation Model Side Cycle Output
Indicator cu. in. cc30S 87026-03S — .060 .983
50S 87026-05S — .100 1.6480S 87026-08S — .160 2.62100S 87026-10S — .200 3.28120S 87026-12S 87066-12S .240 3.93150S 87026-15S 87066-15S .300 4.92
Twin OutletTotal
Standard With Right LubricantDesignation Model Side Cycle Output
Indicator cu. in. cc30T 87026-03T — .030 .492
50T 87026-05T — .050 .82080T 87026-08T — .080 1.31100T 87026-10T — .100 1.64120T 87026-12T 87066-12T .120 1.97150T 87026-15T 87066-15T .150 2.46
* Use No. 67359 closure plug (¹⁄₄" NPT) to plug non-working outlets.
7
Modular Lube® Lubrication SystemsUV, XL & MC Divider Valve Accessories
Note: O-rings are Viton®
Pressure Disc
ReplacementUV, XL Rating
ColorDisc Model Connector
Model psig bar (10/pkg)87934 1450 99 Yellow 69813-1087935 1750 119 Red 69813-12 1⁄8" NPTF(M)87936 3250 221 Purple 25031287937 3700 252 Yel/Nat 250313
Atmospheric Safety Relief IndicatorsHigh pressure ruptures disc, pressure and lubricant vents to the atmosphere.
Pressure RatingUV, XL Model Connector
psig bar87938 500 3487939 1000 6887940 1500 102 1⁄8" NPTF(M)87941 2000 13687942 3000 204
Reset Type Performance IndicatorsHigh pressure extends indicator. Reset the indicator after pressure is relieved.
Model Threads87915 5⁄16" -24 Male x 1⁄8" NPTF(F)
AdapterAdapter connects UV, XL style performance indicators to MC style divider valvesand old style ML. Includes Viton® O-ring.
Pin Type Performance IndicatorsHigh pressure ruptures internal disc and extends indicator.
MC Pressure Disc
ReplacementModel Rating
ColorDisc Model Connector
psig bar (10/pkg)87895 1450 1000 Yellow 69813-1087896 1750 12 Red 69813-12 5⁄16"-24 Male87897 2050 140 Orange 69813-14
Note: O-rings are Viton®
Note: O-rings are Viton®
Pressure Rating Spring/TagModel Connector
psig bar Color87885 1000 70 Green87886 1500 100 Yellow87887 2000 135 Red 5⁄16"-24 Male87888 2500 170 Orange87889 3000 200 Blue
Reset Type Performance IndicatorsHigh pressure extends indicator. Reset the indicator after pressure is relieved.
Model Threads87915 5⁄16" -24 Male x 1⁄8" NPTF(F)
AdapterAdapter connects UV, XL style performance indicators to MC style divider valvesand old style ML. Includes Viton® O-ring.
MC Divider Valve Accessories
UV, XL Divider Valve Accessories
8
ModelSwitch Switch ConduitType Capacity Connector
87070 SPDT15 Amps @ 125/250 VAC
¹⁄₂" - 14 NPSM0.5 Amps @ 125 VDC
Model Maximum Counts87828 99,999
Model Block Type Application/Usage
87905 MC Single and Crossport87823 XL Crossport87824 XL Singling87825 UV Crossport
Switch Switch CSA Model BlockType Capacity Certification
ConduitStyle Connector
85651 UV10 Watts Class I, Group A, B, C & D
87617 MC SPST 200 VDC Class II, Group E, F & G ¹⁄₂" NPT(F)
87618 XL Size 0.5 Amp Hazardous Locations03 thru12
Cycle SwitchCycle Switch attaches to valve with cycle indicator pin, sends electrical signal tocontroller.
Cycle CounterCycle Counter attaches to valve with cycle indicator pin, counts and records cycles.
Proximity SwitchProximity Switch is a magnetic reed switch that attaches to divider valve for use inhazardous environments.
Pressure AdjustmentInlet/ SealModel Min MaxOutlet Materialpsig bar psig bar
87865 250 17 6000 408 ¹⁄₈" NPTF(F) Viton®
Balancing ValveModel 87865 Balancing Valve is used when back pressure differential betweendivider valve outlets exceeds 1000 psi (68 bar).
External Singling/Cross Port KitExternal Cross Port Kit connects alternate outlet ports to combine the volume oftwo divider valves through a single outlet.
Modular Lube® Lubrication SystemsDivider Valve Accessories
9
Modular Lube® Lubrication SystemsDivider Valve Accessories
ModelPressure
Inlet OutletHex Hex Hex Length
Max Opening Material Inlet-in. Outlet-in. in./mm
880511 8000 145 ¹⁄₄" ¹⁄₄" Carbon Steel 3.72/94.5880518-9 psig psig NPTF(F) NPTF(M) 316 S.S. 3.75/95.3880517 550 10 ¹⁄₈" ¹⁄₈" Carbon Steel 3.31880519-9 bar bar NPTF(F) NPTF(M) 316 S.S. 84.1
5000 80⁹⁄₁₆-18 ⁷⁄₁₆-20 Stainless
880015-9psig psig
UNF UNF Steel3/4"
2.75/70340 6bar bar
Check valves maintain prime in feed lines and check back pressure from pressurized lubrication points.
Double Ball, Straight
Model Pressure Inlet Outlet Hex Hex Hex LengthMax Opening Material Inlet-in. Outlet-in. in. / mm
880513 2000 50¹⁄₈" ¹⁄₈" 2.75
psig psig NPTF(F) NPTF(M) Carbon 70.0
880514 140 3.5¹⁄₄" ¹⁄₄" Steel 3.06
bar bar NPTF(F) NPTF(M) 77.7
Ball & Poppet, Straight
Pressure Hex Hex Hex DimensionsModel Inlet Outlet Inlet Outlet in. / mm
Max Opening Material in. in. A B
8805152000psig 50 psig ¹⁄₈" ¹⁄₈" Carbon 3.38 1.25140 bar 3.5 bar NPTF(F) NPTF(M) Steel 86 31.8
Ball & Poppet, 90°
Model Pressure Inlet Outlet Hex Hex LengthMax Opening Material in. in. / mm
87817 7500 psig 20-70 psig ¹⁄₄" NPTF(M) ¹⁄₄" NPSF(F)Carbon
1.38/35.1
87818 500 bar 1.5-5 bar ¹⁄₈" NPTF(M) ¹⁄₈" NPTF(F) 1.19/30.2
130021-36000 psig 31-70 psig
¹⁄₈" NPTF(F) ¹⁄₈" NPTF(M)Steel
1.06/27.0400 bar 2-5 bar
Ball Type, Straight
Mounting BracketModel 250286 (UV) and Model 360675 (MC) Mounting Brackets—Mount divider valve assembly off the face of vertical surfaces. Use two bracketsper divider valve assembly.
Check Valves
13/16"
3/4" 13/16"
3/4" 13/16"
11/16"9/16"
1/2"
3/4"
10
Lubricant flows through Supply Lines between the pump and divider valves, then through Feed Lines between the divider valve and the bearing. Tubing and/or pipe sizes are determined after considering both the length of the line and the specific lubricant intended for use in the system.
Your Lincoln representative can assist you in the proper selection of supply and feed line material to optimize your application.
Listed below is a simplified outline of the installation components offered. For a complete listing of products, please refer to the Installation Components catalog.
TUBING
Hydraulic, Steel, Stainless Steeland Nylon
Single and Multiple TubeClamps
Heavy-Duty, Standard-Duty,Threaded Sleeve and Snap-OnCoupler Tube Fittings
Quicklinc® Tubing Adapter
Zerk-Lock™ Grease FittingAdapters
Non-Metallic
PIPING
Seamless
Continuous Welded
Forged Fittings
Malleable Iron Fittings
316 Stainless Steel Pipe and Fittings
Stainless Steel Fittings
Galvanized Pipe, ThreadedPlug and Fittings
ACCESSORIES
Supply, Feed and Bulk Feed Line Hose
Air Hose
Kits for Hose Repair
Heavy-Duty Air Line QuickDisconnects
AIR CONTROL AND ACCESSORIES
Manual Shut-Off Valves
Pressure Gauges
Lubricant Filters and Strainers
AIRCARE™ AIR PREPARATION SYSTEMS
Modular Air Line Filters,Regulators and Lubricators
Integrated/ModularFilter/Regulator with Gauge
Modular Air Line Combination Units
High-Capacity Air Line Filters,Regulators and Lubricators
High-Capacity Air LineCombination Units
Miniature Air LineComponents—Air Line Filter,Regulator and Lubricator
Miniature Air Line Combination Units
Modular Air Line EquipmentAccessories:Lockout Valve, Quick Clamp,Quick Clamp Wall MountingBracket, Porting Block, QuickMount Pipe Adapters, ManifoldBlock, Pressure Switch, PanelNut, Wall Mount Bracket,Tamper Resistant Cover & Seal Wire
Air Line Equipment Accessories: Wall Mount Bracket, High-Capacity; Mounting Bracket andNut, Miniature; PressureGauges
PIPE FITTINGS
Reducing Bushings
Nipples
Couplings
Reducing Couplings
Street Ells
Tees
Crosses
Adapter Unions
Elbows
Pipe Fitting Adapters
Supply Line Swivels
Feed Line Swivels
Anchor and Junction Blocks
Modular Lube® Lubrication SystemsInstallation Components
11
Modular Lube® Lubrication SystemsIntroduction to Pumps
Modular Pumps
Lincoln’s modular pumps are designed to efficiently supply either grease or oil in automatic systems using divider valve metering devices. Air, hydraulic andmechanically operated units are available. These units are then matched with an appropriate intermediate baseplate, and an appropriate reservoir to make up a pump assembly.
If required, the reservoir can be remotely mounted for ease of filling, utilizing a machine mounted baseplate and pump.
Baseplates contain all of the inlet and outlet connections for the pump and lube system. Intermediate baseplates mounted between the pump and reservoir allow for quick pump removal without disturbing any existing piping. Removal of the pump does not require draining of the reservoir due to an integral check-valve in the baseplate.
All modular reservoirs are compatible with all pumps, offering extreme flexibility insystem design.
12
Model: 87200Ratio: 25:1Displacement: Min. .025 cu. in. .410 cc
Max. .100 cu. in. 1.639 ccAir Pressure: Min. 65 psig 4.5 bar
Max. 150 psig 10 bar
Dimensions (HxWxL): 2.75" x 9.88"x 2.75" 69.8 x 250.9 x 69.8 mmCylinder Type: Single acting, spring returnAir Valve Requirement: 3-Way
Model 87216Model: 87216Ratio: 50:1Displacement: Min. .010 cu. in. .164 cc
Max. .050 cu. in. .820 ccAir Pressure: Min. 35 psig 2.5 bar
Max. 150 psig 10 bar
Dimensions (HxWxL): 2.75" x 9.88"x 2.75" 69.8 x 250.9 x 69.8 mmCylinder Type: Single acting, spring returnAir Valve Requirement: 3-Way
Model 130179Model: 130179Ratio: 25:1Displacement: Min. .25 cu. in. 1.0 cc
Max. 1.0 cu. in. 16.39 ccAir Pressure: Min. 65 psig 4.5 bar
Max. 150 psig 10 bar
Dimensions (HxWxL): 5.50" x 15.38"x 4.50" 139.7 x 290.6 x 114.3 mmCylinder Type: Single acting, spring returnAir Valve Requirement: 3-Way
Notes:Model 87200, 87216, 130280 pumps do not have valved pistons. Use Modular Lube reservoirs only.Model 130179 pump with valved piston uses Modular Lube reservoir or pressurized (max. 2000 psig/140 bar) lube supply.All pumps include Viton® O-rings for standard or synthetic lubricant.
Model 87200
Modular Lube® Lubrication SystemsAir Operated Modular Pumps
Model 87202Model: 87202Ratio: 7:1Displacement: Min. .025 cu. in. .100 cc
Max. .10 cu. in. 1.639 ccHydraulic Pressure: Min. 275 psig 20 bar
Max. 2000 psig 138 bar
Dimensions (HxWxL): 2.13" x 9.50"x 1.88" 54.1 x 241.3 x 47.7 mmCylinder Type: Double actingDirectional Valve Requirement: 4-Way
Notes:Pump includes Viton® O-rings for standard or synthetic lubricants.Pump does not have valved pistons. Use Modular Lube reservoirs only.
Hydraulic Operated Modular Pumps
Modular Lube® Lubrication SystemsBaseplates & Reservoirs
Modular Pump Baseplates Mount pump directly to a modular reservoir with intermediate baseplate.Use machine mounted baseplates with remote reservoirs.
Note:Baseplates include Viton® O-rings for standard or synthetic lubricants.
Use with Air/ Lube Lube Dimensions - in. / mm Atmos.Model Descrip. Pump Hydraulic Inlet Outlet Height Width Depth IndicatorModel Inlet psi / bar
87218 Inter- 87200, ¹⁄₈" — 3.25 3.25mediate 87202, NPTF(F) 82.6 82.6
87204 87216 ¹⁄₄" ¹⁄₄" 3.19 4.69 1.00 1450
Machine NPTF(F) ³⁄₈" NPTF(F) 78.7 119.1 25.4 99
130095Mount ¹⁄₄" NPTF(F) 4.00 4.50 150
130179 NPTF(F) 101.6 114.3 38.1
Modular Reservoirs for Oil Systems
Note:All reservoirs will accept 87218 Intermediate Baseplates.
Type Capacity Dimensions - in. / mmModel Style Outlet Gal. Liter cu. in. cc Material Height Width Depth
87400 .625 2.4 144 235015.69 6.00 5.31399 152.6 135.0
87413Cylin- ¹⁄₂"
1.25 4.7 289 475017.69 7.31 7.47
drical NPTF(F) Acrylic 450 186.0 189.7
87417 5 18.9 1155 1890017.50 12.56445.2 319.0
87418Tank ³⁄₈"
3 11.3 693 11350 Steel10.12 13.50 11.56
NPTF(F) 257.4 343.4 294.1
87419 1.5 5.7 346 567510.50 7.56267.1 192.3
Modular Reservoirs for Grease Systems
* Includes visual level indicator rod.
Note:
All reservoirs accept Model 87218 Intermediate Baseplates. Reservoirs include standard ¹⁄₂" NPTF(F) outlet.
Capacity Dimensions - in. / mmModel lbs. Kg. cu. in. cc Material Height Width Depth
87406 10 4.54 300 490017.69 7.31 7.47450 186.0 189.7
87407 5 2.27 150 2450Acrylic 15.69 6 5.94
399 152.6 150.9
87416 15 6.82 450 735025.19 7.47640.8 189.7
87421* 10 4.54 300 490017.69 7.31
Steel450 186.0 7.41
87423* 15 6.82 450 735025.19 188.2640.8
13
14
Modular Lube® Lubrication SystemsModular Pump Accessories
Model Use with Reservoir # Switch Type Electrical Rating84235 87417, 87418, 87419
7 Amps84250 84700 SPDT125/250 VAC84252 87414
87852 87402, 87403, 87406, 87407, 87416SPDT 15 Amps
125/250 VAC
Low-Level SwitchesLow-level switches for modular design reservoirs.
Model Pressure Rating - psig / bar Switch Type Electrical Rating87851 1450 / 99 SPDT 15 Amps, 125/250 VAC
High-Pressure SwitchHigh-pressure switch signals blockage and returns pump output to reservoir.
Model Use with Pump Model Switch Type Electrical Rating83671 87240, 87228 15 Amps; 125, 250, 480 VAC
83696 87239SPDT .5 Amp 125 VDC
.25 Amp 250 VDC
Low-Level Switch Assembly Kits for pneumatic and electric reciprocating pumpswith self-contained reservoirs.
15
Modular Lube® Lubrication SystemsModular LP Pumps
Modular LP-Style Reservoirs Mount directly to LP pumps. Includes 3000 psig (200 bar) gauge and 900 psig (60 bar) atmospheric indicator. Transparent, polycarbonate construction.
Lubricant Capacity Air Lube Dimensions - in. / mmModelType lb/pint kg liter cu. in. cc Hydraulic Outlet Height Width Depth
87402 Grease 3 lb 1.36 — 90 1475 13.37587403 5 lb 2.27 — 150 2450 ¹⁄₈" ¹⁄₈" 340.0 6.78 7.06
87405 Oil 5 pint — 2.36 144 2365 NPSM(F) NPSM(F) 10.312 172.2 179.6262.3
Model: 87212Type: HydraulicRatio: 5:1Hydraulic Pressure: Min. 200 psi 14 bar
Max. 1000 psi 68 barLubricant Output/Cycle: Min. .010 cu. in. .164 cc
Max. .060 cu. in. .983 ccCylinder Type: Double actingDirectional Valve Requirements: 4-Way
Model 87212
Model: 87214Type: AirRatio: 18:1Air Pressure: Min. 60 psi 4 bar
Max. 200 psi 14 barLubricant Output/Cycle: Min. .010 cu. in. .164 cc
Max. .060 cu. in. .983 ccCylinder Type: Single actingDirectional Valve Requirements: 3-Way
Model 87214
Note:Pumps include Buna-N O-rings.
16
Modular Lube® Lubrication SystemsReciprocating Pumps
Model: 87240Lubricant Type: GGrreeaasseeLubricant/Air Ratio: 40:1Output/Min. @ 100 psig Air: 12 cu. in. 197 ccReservoir Capacity:* 12 lbs. 5.45 kg
360 cu. in. 5900 cc
Air Inlet: ¹⁄₈" NPTF(F)
Lube Outlet: ¹⁄₄" NPTF(F)Dimensions (HxWxD): 20.5" x 9" x 16.25" 521.3 x 229 x 413 mm
Model 87240 Air-Operated Reciprocating Pump
Model: 87239Lubricant Type: OOiillLubricant/Air Ratio: 40:1Output/Min. @ 100 psig Air: 12 cu. in. 197 ccReservoir Capacity: * 15 pints 7.1 liter
433 cu. in. 7100 cc
Air Inlet: ¹⁄₈" NPTF(F)
Lube Outlet: ¹⁄₄" NPTF(F)Dimensions (HxWxD): 20.5" x 9" x 16.25" 521.3 x 229 x 413 mm
Model 87239 Air-Operated Reciprocating Pump
* Transparent Acrylic Reservoir
Note:Both models require a 3-way air valve.
Atmospheric Indicator Pressure: Model 87240—2650 psi/180 barModel 87239—1450 psi/98 bar
Model: 87228Lubricant Type: GGrreeaasseeElectrical Requirement: 220/440, 60 Hz 3 phOutput/Minute: 18 cu. in. 295 ccReservoir Capacity: * 12 lbs 5.45 kg
360 cu. in. 5900 cc
Lube Outlet: ¹⁄₄" NPTF(F)Dimensions (HxWxD): 25.38" x 9.94" x 18.06" 645 x 253 x 459 mmRelief Valve: 3700 psig 238 bar
Model 87228 Electric-Operated Reciprocating Pump
* Transparent Acrylic Reservoir
* Transparent Acrylic Reservoir
17
Modular Lube® Lubrication SystemsFlowMaster® Hydraulic Pump
High-performance FlowMaster hydraulic pumps combine rotary-driven pumpmotors with reciprocating pump tubes and flexible control features that perform indesert heat and arctic cold. Integrated control manifold adjusts the amount oflubricant and operating pressure. The pump’s output is adjustable from 7 to 45cubic inches per minute.
SSuuppppllyy IInnlleettHHyyddrraauulliicc PPrreessssuurree,, MMaaxx..:: 3000 psig 200 barOOppeerraattiinngg IInnlleettHHyyddrraauulliicc PPrreessssuurree:: 300 to 420 psig 20 to 32 barHHyyddrraauulliicc IInnlleett FFllooww:: Up to 7 gpm 28 l/minPPuummpp RRaattiioo wwiitthh MMaanniiffoolldd:: 9:1 at low inlet pressure (300 to 350 psi/20 to 25 bar)
and low inlet flow (below 2 gpm/7 lpm)pump ratio approaches 11:1 ratio at higher inlet pressure and flow
PPuummpp OOuuttppuutt:: 7 - 45 in3/minOOppeerraattiinngg TTeemmppeerraattuurree:: -20° to +150°F -10° to +65°CSSoolleennooiidd VVaallvvee CCooiill:: 24 VDCHHyyddrraauulliicc IInnlleett PPoorrtt:: SAE 4TTaannkk RReettuurrnn PPoorrtt:: SAE 6PPuummpp OOuuttlleettss:: 1⁄4" NPTFMMaaxx.. HHyyddrraauulliicc FFlluuiidd TTeemmpp:: 200°F 93°C
11.46 (291)9.08(231)
4.61(117)
9.54 (242)
3/8 NPTFTank Port
A
B
1.25 (32)
3/8 NPTFInlet Port
PressureGage
1/4 NPTFPump
Outlets
19.517
BB
15.090
AA
FFoorr tthhee ccoommpplleettee ssyysstteemm,, wwhheenn oorrddeerriinngg112200## oorr 440000## vveerrssiioonnss aallssoo oorrddeerr tthhee ffoolllloowwiinngg::
112200## DDrruumm CCoovveerr 8844661166FFoolllloowweerr AAssssyy 8855449922VVeenntt VVaallvvee AAssssyy 8844999900
440000## DDrruumm CCoovveerr 227711660066FFoolllloowweerr AAssssyy 227700998822VVeenntt VVaallvvee AAssssyy 227711660055
CCoonnttaaiinneerr PPuummpp -- iinn.. ((mmmm)) PPuummpp BBuucckkeett--iinn.. ((mmmm))SSiizzee AA BB AA BB
35 lb. 13.69 23.50 14.59 24.40(348) (597) (371) (620)
60 lb. 19.00 28.81 19.90 29.70(483) (732) (505) (754)
90 lb. 27.50 37.31 28.40 40.13(699) (942) (721) (1,019)
120 lb. 27.50 37.31 28.40 40.13(699) (942) (721) (1,019)
400 lb. 34.00 43.81 34.00 44.94(864) (1,113) (864) (1,142)
Capacity Solenoid Adjustable AdjustableModel lbs gal L Manual Override Flow Control Pressure Control85247 120 18 68 Yes85480 120 18 6885481 60 8 3085482 400 55 20885483 35 5 19 No Yes Yes85486 35 5 1985586* 400 55 20885610** 400 55 20885670 90 10 38 Yes Fixed Fixed85675 60 8 3086261*** 35 5 19 No Yes Yes
Pump Only Models
*Heavy-duty model **Low temperature model (-60°F) ***Kit consisting of pump, follower, bucket cover and hardware
18
Modular Lube® Lubrication SystemsMCLP Pumps
Model: 130201BCCType Drive: RotaryShaft Description: Left-hand end, long shaftGear Ratio: 2:1Decimal Gear Ratio: .5Cam: Single lobePump Heads: (Model 130335) 10 mm (2 each)Performance Indicator: 7300 psig / 500 bar
Model 130201BCCMCLP Pump complete with pump heads.
Model: 130200GEEType Drive: RotaryShaft Description: Left-hand endGear Ratio: 8:1Decimal Gear Ratio: .125Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130200GEE
Model: 130200KEEType Drive: RotaryShaft Description: Left-hand endGear Ratio: 21.5:1Decimal Gear Ratio: .047Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130200KEE
MCLP PumpsFor natural gas engine/compressor lubrication systems.
19
Modular Lube® Lubrication SystemsMCLP Pumps
Model: 130150LEEType Drive: RatchetShaft Description: Right-hand end, clockwise rotationGear Ratio: 1:2Decimal Gear Ratio: 2Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130150LEE
Model: 130300GEEType Drive: RotaryShaft Description: Right-hand endGear Ratio: 8:1Decimal Gear Ratio: .125Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130300GEE
Model: 130300KEEType Drive: RotaryShaft Description: Right-hand endGear Ratio: 21.5:1Decimal Gear Ratio: .047Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130300KEE
Model: 130500GEEType Drive: Right-angle rotaryShaft Description: Left-hand end, long shaftGear Ratio: 8:1Decimal Gear Ratio: .125Cam: Single lobePump Heads (Max of 2): Order separatelyPerformance Indicator: Dependent on pump head
Model 130500GEE
Notes:1. Recommended camshaft speed (RPM) for all pumps is: 12 to 75 rpm.2. MCLP output (per pump) = Input speed x decimal ratio x pump output factor* = pints per day* See MCLP pump head chart for pump output factor
20
Modular Lube® Lubrication SystemsPump Accessories
ModelPump Heads Filter Inlet Max. Inlet PressureServed Size psig / bar
130067 2 10 Micron 1" NPTF(F) 50 / 3.4
MCLP Pump Inlet Filters
For Pressure Exceeding - psig / barModel Pneumatic Hydraulic Connections
15104 100 / 6.8 500 / 34 ¹⁄₈" NPTF(F) x ¹⁄₈" NPTF(M)
Flow RestrictorFlow restrictor for LP Pumps with high air or hydraulic supply pressure.
ModelMax. Pressure Gauge Reading Reservoir Outlet
psig / bar Capacity Adapters
130117 3000 / 204 16 oz.⁵⁄₁₆" - 24 UNF(M), ⁷⁄₁₆" - 20 UNF(M),
¹⁄₈" NPTF(M), ¹⁄₄" NPTF(M)
Filler PumpManual pump for system purging and troubleshooting.
Max. Oil Inlet/OutletModel Signal Operating Viscosity Air Electrical 3rd Party
Type Pressure Range Air Oil Supply Rating Approvalspsig / bar
87862 Pneum.6000 60 SSU- ¹⁄₈" ¹⁄₄"
150 psi max — —1 amp, 115 VAC CSA Class I, Group D
87601 Electric 408 3000 SSU NPTF(F) NPTF(F) — .5 amp, 32 VDC Class II, Group E, F & G
No-Flow ValvesMCL pump no-flow valves shut down engine or signal fault if oil flow is interrupted.
Notes:1. Minimum flow rate .060 cu. in./minute with time delay setting of 90 seconds.2. Includes Viton® oil seals.
Max. Pump Output Max.
Model Piston Working Factor Inlet Pump Pump PerformanceDiameter Pressure Pressure Inlet Outlet Indicator
psig/bar Min 1 Turn Max 5 Turns psig/bar psi/bar
130332 7mm 8000/544 .10 .852 50 ³⁄₈" ¹⁄₄" 5500/374130335 10mm 3500/238 .213 1.491 3.4 NPTF(F) NPTF(F) 3250/221
MCLP Pump Heads
Part Element Size Maximum Connections Hex Body No. micron Pressure in. Size - in.
*84239 10 6000 psig / 408 bar 1⁄4 NPTF (F) 11⁄4
In-Line Lubricant Filters Remove solid contaminants before delivering lubricants to the supply line.
* In-line filter with Viton® seal.
21
Modular Lube® Lubrication SystemsPump to Point Lubricators
Model 55i Lubricator PumpUniversal lubricator pump fits most major manufacturers’ lubricator boxes. One piece pump body eliminates leak points.
PistonSight
Max. Operating Max. Oil Max. OutputModel Type Dia. Inlet
GlassPressure Viscosity Per Stroke
in. / mm psi / bar (SUS) Drops (in3 / cc)
880550 Vacuum ¹⁄₄" / 6.4 Suction 6000 / 400 9 (.0184 / .302)
880560 Feed ³⁄₈" / 9.5 Tube 3500 / 240 21 (.0415 / .680)
880551 Press. ¹⁄₄" / 6.4 Yes 6000 / 400 8000 9 (.0184 / .302)Inlet ¹⁄₈" 540
880561 (Manifold) ³⁄₈" / 9.5 NPTM 3500 / 240 21 (.0415 / .680)Feed
880552Direct
¹⁄₄" / 6.4¹⁄₈"
No 6000 / 400 9 (.0184 / .302)Feed NPTF
End Rotary Drive LubricatorsInternal Gear and RatchetDrive Data: Type—End rotary with internal gear and ratchet. 37.5:1 ratio.
Rotation—Either clockwise or counterclockwise. Power Source—Machine drive; not recommended for motor drive. Maximum Input Speed—700 RPM.
Note: Number following dash in the part number indicates quantity of pumpsincluded.
ModelReservoir Max. No. Drive Service SheetCapacity of Pumps Location Number
800037-1,2,3,4 4 pint / 1.9L 5 RH M2-26800028-3 4 pint / 1.9L 5 LH M2-43800131-5 8 Pint / 3.8L 7 RH M2-25800019-5 8 Pint / 3.8L 7 LH M2-40
ModelDimensions—in. / mm Shaft
A B C D E Dia.
800037-1,2,3,45¹⁄₂ / 140 10⁵⁄₈ / 270
800028-33 / 76 6⁹⁄₁₆ / 167 10³⁄₈ / 264 ⁵⁄₈ / 16
800131-58³⁄₄ / 222 14¹⁄₈ / 359
800019-5
Notes: Standard Viton® seals.Sight glass is Polysulfone – check for compatibility with synthetic oils.See Pump to Point Lubricator Accessories page for armored site glass kit (model 250176).
Modular Lube® Lubrication SystemsPump to Point Lubricators
22
Internal Ratchet Drive LubricatorsDrive Data: Type—Internal 75-tooth ratchet gear.
Rotation—See chart for power stroke direction.Power Source—Machine drive.
Note: Number following dash in the part number indicates quantity of pumpsincluded.
ModelReservoir Max. No. Drive Power Service SheetCapacity of Pumps Location Stroke Number
800065-1 2 pint / .95L 2 LH CW M3-31800376-2 3 pint / 1.4L 3 RH CW M3-31800118-2 4 Pint / 1.9L 5 RH CW M2-164800100-2 4 Pint / 1.9L 5 LH CW M3-31800031-3,5 8 Pint / 3.8L 5 RH CW M3-31
ModelDimensions—in. / mm Shaft
A B C D E Dia.
800065-1 3³⁄₄ / 95 5³⁄₈ / 137 10¹⁄₂ / 269
800376-2 5¹⁄₂ / 140 7¹⁄₈ / 181 10³⁄₄ / 273
800118-2 5¹⁄₂ / 140 10⁵⁄₈ / 270 3 / 76 6⁹⁄₁₆ / 167 10³⁄₈ / 264 ⁵⁄₈ / 16
800100-2 5¹⁄₂ / 140 10⁵⁄₈ / 270 10³⁄₄ / 273
800031-3,5 8³⁄₄ / 222 14¹⁄₈ / 359 10³⁄₄ / 273
End Rotary Drive LubricatorsSpur GearDrive Data: Type—End rotary with spur gear. 112.5:1 ratio.
Rotation—Either clockwise or counterclockwise. Power Source—Machine drive; not recommended for motor drive.
Note: Number following dash in the part number indicates quantity of pumpsincluded.
ModelReservoir Max. No. Drive Service SheetCapacity of Pumps Location Number
800066-2,3 4 pint / 1.9L 5 RH M2-20800143-3 4 pint / 1.9L 5 LH M2-136800289-4,5 8 Pint / 3.8L 7 RH M3-21
ModelDimensions—in. / mm Shaft
A B C D E Dia.
800066-2,35¹⁄₂ / 140 10⁵⁄₈ / 270
800143-3 4 / 102 6⁹⁄₁₆ / 167 10³⁄₄ / 273 ⁵⁄₈ / 16
800289-4,5 8³⁄₄ / 222 14¹⁄₈ / 359
23
Modular Lube® Lubrication SystemsPump to Point Lubricators
Right-Hand Bottom Vertical Drive LubricatorsFilter DriveNote: Number following dash in the part number indicates quantity of pumps
included.
Model Reservoir Max. No. Ratio Service SheetCapacity of Pumps Number
800192-3 4 pint / 1.9L 3 30:1 M2-37
ModelDimensions—in. / m Shaft
A B C D Dia.
800192-3 9³⁄₄ / 248 2 / 51 5 / 127 10³⁄₄ / 273 ¹⁄₂ / 13
Rear Rotary Drive LubricatorsNote: Number following dash in the part number indicates quantity of pumps
included.
Model Reservoir Max. No. Drive Ratio Service SheetCapacity of Pumps Location Number
800469-2 3 pint / 1.4L 2 LH 80:1 M2-48800621-4 8 Pint / 3.8L 6 LH 60:1 M2-42800784-2 8 Pint / 3.8L 6 LH 137.5:1 M3-18
Model Dimensions—in. / mm Shaft A B C Dia.
800469-2 7¹⁄₈ / 181 5³⁄₁₆ / 132 2⁹⁄₃₂ / 71 ⁵⁄₈ / 16
800062-4 10⁵⁄₈ / 270 5³⁄₁₆ / 132 1⁷⁄₈ / 48 ⁵⁄₈ / 16
800784-2 14¹⁄₈ / 359 5³⁄₁₆ / 132 2¹⁄₄ / 57 ¹⁄₂ / 13
Modular Lube® Lubrication SystemsPump to Point Lubricators
24
Left-Hand Rear Gearhead Drive LubricatorsNote: Number following dash in the part number indicates quantity of pumps
included.
Model Reservoir Max. No. Ratio Service SheetCapacity of Pumps Number
800059-1,2 4 pint / 1.9L 5 60:1 M2-19
ModelDimensions—in. / mm Shaft
A B C D E Dia.
800059-1,2 5¹⁄₂ / 140 10⁵⁄₈ / 270 3¹³⁄₁₆ / 97 6⁹⁄₁₆ / 167 10⁷⁄₈ / 276 ⁵⁄₈ / 16
End Rotary Drive Tandem LubricatorsDrive Data: Type—End rotary all gear.
Rotation—Either clockwise or counterclockwise. Power Source—Machine drive; also suitable for motor drive.
Note: Pumps and slot covers must be purchased separately.
Model Reservoir Max. No. Drive Ratio Service SheetCapacity of Pumps Location Number
847400 8 pint / 3.8L 6 RH 300:1 M2-218
ModelDimensions—in. / mm Shaft
A B C D E Dia.
847400 8³⁄₄ / 222 16⁵⁄₁₆ / 414 2⁵⁄₈ / 67 4¹⁄₄ / 108 5⁷⁄₁₆ / 138 ⁵⁄₈ / 16
Modular Lube® Lubrication SystemsPump to Point Lubricator Accessories
25
Model 250176 Armored Sight Glass KitWith pyrex sight tube.
Model 880555 Lube SentryMonitors camshaft rotation and reservoir level.
Model 880556 Lube SentrySame as Model 880555 except suction tube is 1/2" shorter.
Model 880496 Oil Level RegulatorAutomatically fills lubricator reservoir.
Model 880463* Lubricator Flow SwitchMonitors Model 55i lubricant flow.
Model 880466* Lubrication Flow SwitchSame as Model 880463 except includes terminal for series wiring.
*Use with non-conductive fluids only. Lubricator must be properly grounded.
26
Modular Lube® Lubrication SystemsSystem Controls
Model Register Oil Inlet/OutletMax. Pressure Rating
psig / bar
87806 200 counts per pint ¹⁄₄" NPTF(F) 6000 / 408
Flow MeterFlow meter measures and records oil flow to the system.
Max.
Model System(s) Electrical Power Display Alarm Time 3rd PartyMonitored Requirements Record Approvalspints Min. Max.
87610 1 115 VAC, 50-60 Hz999,999
37.5 10 CSA Class I, Group D87611 2 24 VDC Sec. Min. Class II, Group E, F & G
Cycle MonitorsCycle Monitors monitor and record oil flow volume delivered to lube points and signal fault if flow stops or diminishes significantly.
Model 84501 Program Timer—Solid StateDesigned to control the lubrication cycle frequency of air-operated single-strokepumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump.
Off Time On TimePower Approvals Switch(Cycle Time) (Pumping Time)
Requirements CapacityMin Max Min Max
20 Sec. 24 Hrs. 10 Sec. 1 Min. 120/230 VAC UL, CSA 120 VAC, 5 Amps24 Sec. 50/60 Hz 230 VAC, 1.5 Amps
Model 84511 Economy Timer for Single Stroke PumpsUses a timing motor, cam and Micro-Switch to turn pump off and on. NEMA 1enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive.
Off Time On TimePower Approvals Switch(Cycle Time) (Pumping Time)
Requirements CapacityMin Max Min Max
5 Min. 1 Hr. 30 Sec. 90 Sec. 120 VAC, 60 Hz UL, CSA 10 Amps
Built-In Program Options Enclosure Ambient Operating Temperature Range
3 Hr. Program Prelube Rating Dimensions-in./mm Minimum MaximumMemory Function Height Width Depth
Yes No Yes No NEMA #1 8¹⁄₄ 6¹³⁄₁₆ 4¹⁵⁄₁₆ 0°F 130°F210 173 125 -18°C 54°C
Enclosure
RatingDimensions - in. / mm
Height Width Depth
NEMA 1 5 / 127 3¹⁄₄ / 82.5 3¹⁄₂ / 89
Note: Off-time selectable in 5 minute intervals.
Note:Refer to Technical Manual for a full explanation of available program options.
27
Modular Lube® Lubrication SystemsSystem Controls
Model 85530 Lubrication System ControllerControls lubrication frequency, master divider valve cycle and monitors supply linepressure. The LCD displays operating status.
Model 84015 Timer—12-24V DCSolid-state microprocessor-based controller for automated lubrication systems onmobile equipment or where AC power is not available. Rugged construction withliquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle.
Off Time**Fixed On Time Power Switch(Cycle Time)(Pumping Time) Requirements Capacity
Min. Max.
2.5 Min. 80 Min. 75 Sec. 10-30 VDC 5 Amps25 MA*
Enclosure Ambient Operating Temperature Range
RatingDimensions-in. / mm
Minimum MaximumHeight Width Depth
NEMA 12 5¹⁄₄ / 133 3¹⁄₈ / 79 3 / 76 0°F / -18°C 131°F / 55°C
* Less load.** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes.
Lube CycleMax. Pumping Time
Timer Mode Counter Mode Count Before AlarmOff Time Off CountsMin. Max. Min. Max. Rate* Min. Max.
1 . 9,900 1 99,000 30/Sec. 1 99Minute Minutes Count Counts @ 50% Minute Minutes Duty Cycle
Notes: Model 85530 is CSA/NRTL approved.
* Minimum duration of count signal is 33 milliseconds.
Power Requirements (less load) Pump, Ambient EnclosureSolenoid, Temperature
RatingDimensions-in. / mm
Voltage Current or Alarm RangeCapacity Height Width Depth
120 VAC, 50/60 Hz 85 MA360 VA 32° to 122°F NEMA 9¹⁄₂ 8¹⁵⁄₁₆ 4¹⁄₈230 VAC, 50/60 HZ 45 MA
-0° to +50° C 12 241 227 10524 VDC 250 MA 5 Amps
Modular Lube® Lubrication SystemsSystem Controls
28
Model 85500 System Sentry IIThe ultimate automated lubrication system controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length or bearing back-pressure. System Sentry II is always on the job, making sure that every lube point is lubricated when it’s supposed to be.
• Solid-state controller with LCD status display and 16-button keypad for system programming
• Controls up to two pumps with as many as two lube zones per pump• Fully programmable monitoring and alarm functions• Be set up to monitor every lube point for lubricant flow during each lubrication event• Easy to understand prompts reported by simple English language messages in real time
Some functions require optional accessories. See chart on page 30. Use a maximum or 48 sensors and three accessory Sensor Boards (order separately—16 sensors per board) to monitor lube points. For more than 48 sensors, use Model 85510 Satellite plus additional Sensor Boards for a maximum of 1536 lube points.
Model 243100 Sensor Wire100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors tomonitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters).
Lube CycleMax. Pumping Time
Timer Mode Counter Mode Count Before AlarmOff Time Off Counts NetMin. Max. Min. Max. Rate* Min. Max. Wt.
1 9,900 1 99,000 30/Sec. 1 99 18 lbs.Second Minutes Count Counts @ 50% Second Minutes 8.1 kgDuty Cycle
Note: Model 85500 is CSA/NRTL approved.* No external load, no sensors.
* Minimum duration of count signal is 33 milliseconds.
Power Requirements (less load) Pump, Ambient EnclosureSolenoid, Temperature Dimensions-in. / mm
Voltage Current or Alarm Range RatingCapacity Height Width Depth
120 VAC, 50/60 Hz 250 MA*360 VA 32° to 122°F NEMA 16 14 4⁷⁄₈230 VAC, 50/60 HZ 125 MA*
0° to 50° C 12 241 227 10524 VDC 600 MA* 5 Amps
Modular Lube® Lubrication SystemsSystem Controls
29
Model 247333 Pressure TransducerPressure Transducer signals actual system pressure via LCD display of SystemSentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximumlength of wire between transducer and monitor is 30 (9.1m) feet.
Model 250365 Sensor BoardPlug-in accessory board used with Model 85500 that allows the attachment of upto 16 lube flow sensors. Model 85500 comes without boards installed and can holdup to a total of three.
Sensor AssembliesSensor assemblies consist of a check body and lube sensor with attached 30'cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors havea ³⁄₈" pipe thread for conduit connection and a Viton® O-ring seal. Check bodies terminate in a ¹⁄₈" NPTF male thread for attachment to a bearing or other lubricantinlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to monitor is 500 feet (152m).
Range Accuracy Proof Pressure Ambient Voltage EnclosureConnection Temp. Input Output OffsetNEMA 4X
0 to±1%
7500 psig ¹⁄₄" NPT -20° to 180° F 10 to 1-6 1 Rating4000 psi 517 bar Male Thread -29° to 82° C 30 VDC VDC 300 Series276 bar VDC Stainless
Steel
Lubricant Min. Flow Min. IntervalModel Description ConstructionTemp. Range Per Event
Between LubeFlow Event
250400Straight Sensor
Assembly Brass Sensor
25049090° Sensor & Plated Steel
32° to 145° FAssemblyCheck Body
0° to 63° C 30 Seconds
250500Straight Sensor Sensor &
Assembly Check Body
25059090° Sensor 316 Assembly Stainless Steel
.004 cu. in./.066 cc@ 32°F /0°C to
125°F/52°C
.008 cu. in./.131 cc@ 126°F to 145°F
(53°C to 63°C)
Modular Lube® Lubrication SystemsSystem Controls
30
Pressure Sensor Sensor WireFunction Switch Board Sensors #243100 (100')
#69630 #250365 Note 2 Note 3
Lube Controller1 Pump, 1 Zone Optional 1 — — —Note 1
Lube Controller,1 Pump, Optional 1 — — —Up to 3 Zones
Lube Controller,2 Pumps, 1 Zone Optional 1 — — —Per Pump
Lube Controller,2 Pumps, Up to 2 Optional 1 — — —Zones Per Pump
Lube Point Required Required RequiredMonitoring — 1 per each 1 per Quantity≤ 48 Points 16 Sensors Lube Point As Needed
Lube Point Required Required RequiredMonitoring — 1 per each 1 per Quantity> 48 ≤ 1536 Points 16 Sensors Lube Point As Needed
Note 1: Controller may be operated without a pressure switch. Pressure switch may be used to monitor supply line pressure.
Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors instraight or 90° configuration as required.
Note 3: Maximum distance between monitor and sensor is 500' (152 meters).
Use This Guide to Select Accessories for Model 85500 System Sentry II
31
Modular Lube® Lubrication SystemsSystem Controls
Model 83354 Signal MonitorDesigned to provide visual and audible indication of system operation and failure.Utilizes signal from system controller. Includes model 69606 Alarm Horn mountedon enclosure door.
PowerIndicator Lamps
AudibleDimensions - in / mm
Requirement Power Lube System AlarmOn System On Failure Height Width Depth
115 VAC69606 Horn 10 8 650/60 Hz Green Amber Red(included) 254 203 15235 VA
Electric Solenoid-Operated Air Valves
EElleeccttrriiccaall CChhaarraacctteerriissttiiccssPPoowweerr IInnrruusshh HHoollddiinngg AAiirr AAmmbbiieenntt CCvv MMaaxx.. CCoonndduuiittMMooddeell TTyyppee
RReeqquuiirreemmeennttss CCuurrrreenntt CCuurrrreenntt IInnlleett// TTeemmppeerraattuurree FFaaccttoorr PPrreessssuurree CCoonnnneeccttiioonnAAmmppss AAmmppss OOuuttlleett RRaannggee ppssii // bbaarr
110 VAC, 50 Hz350244 120 VAC, 60 Hz .11 .07
4-Way 8.4 VA 0° to 120°F 1.2220 VAC, 50 Hz -18° to 49°C
350245 240 VAC, 60 Hz .055 .0358.4 VA 1⁄4" 1⁄2" NPS(F)
110 VAC, 50 Hz NPT(F)350241 120 VAC, 60 Hz .11 .07
8.4 VA 150220 VAC, 50 Hz 10.3
3502423-Way
240 VAC, 60 Hz .055 .035 .188.4 VA
350282 12 VDC 0° to 140°F6 WattsN/A N/A
1⁄8" -18° to 60°CN/A
350283 24 VDC NPT(F)6 Watts
68586 2-Way120V, 60 Hz
.2 .13⁄8"
2.4 1⁄2" NPT(F)12 VA NPT(F)
274398 3-Way 24 VDC N/A N/A1⁄4" .5 N/A
8.5 Watts NPT(F)110 VAC, 50 Hz 3⁄8" 0° to 120°F
244727 3-Way 120 VAC, 60 Hz .12 .09 NPT(F) -18° to 49°C 4.41⁄2" NPT(F)
11 VA
32
Modular Lube® Lubrication SystemsNumerical Index
Model No. Page No. Model No. Page No. Model No. Page No. Model No. Page No.
15104 . . . . . . . . . . . . . . . . . 2067359 . . . . . . . . . . . . . . . . . . 668586 . . . . . . . . . . . . . . . . . 3168645 . . . . . . . . . . . . . . . . 4, 569606 . . . . . . . . . . . . . . . . . 3169630 . . . . . . . . . . . . . . . . . 3069813-10 . . . . . . . . . . . . . . . 769813-12 . . . . . . . . . . . . . . . 769813-14 . . . . . . . . . . . . . . . 783354 . . . . . . . . . . . . . . . . . 3183671 . . . . . . . . . . . . . . . . . 1483696 . . . . . . . . . . . . . . . . . 1484015 . . . . . . . . . . . . . . . . . 2784235 . . . . . . . . . . . . . . . . . 1484239 . . . . . . . . . . . . . . . . . 2084250 . . . . . . . . . . . . . . . . . 1484252 . . . . . . . . . . . . . . . . . 1484501 . . . . . . . . . . . . . . . . . 2684511 . . . . . . . . . . . . . . . . . 2684616 . . . . . . . . . . . . . . . . . 1784700 . . . . . . . . . . . . . . . . . 1484990 . . . . . . . . . . . . . . . . . 1785220 . . . . . . . . . . . . . . . . . 1785244 . . . . . . . . . . . . . . . . . 1785247 . . . . . . . . . . . . . . . . . 1785480 . . . . . . . . . . . . . . . . . 1785481 . . . . . . . . . . . . . . . . . 1785482 . . . . . . . . . . . . . . . . . 1785483 . . . . . . . . . . . . . . . . . 1785486 . . . . . . . . . . . . . . . . . 1785487 . . . . . . . . . . . . . . . . . 1785492 . . . . . . . . . . . . . . . . . 1785500 . . . . . . . . . . . 28, 29, 3085510 . . . . . . . . . . . . . . . . . 2885530 . . . . . . . . . . . . . . . . . 2785585 . . . . . . . . . . . . . . . . . 1785586 . . . . . . . . . . . . . . . . . 1785610 . . . . . . . . . . . . . . . . . 1785651 . . . . . . . . . . . . . . . . . . 885670 . . . . . . . . . . . . . . . . . 1785671 . . . . . . . . . . . . . . . . . 1785675 . . . . . . . . . . . . . . . . . 1786258 . . . . . . . . . . . . . . . . . 1786261 . . . . . . . . . . . . . . . . . 1787026-03S . . . . . . . . . . . . . . 687026-03T . . . . . . . . . . . . . . 687026-05S . . . . . . . . . . . . . . 687026-05T . . . . . . . . . . . . . . 687026-08S . . . . . . . . . . . . . . 687026-08T . . . . . . . . . . . . . . 687026-10S . . . . . . . . . . . . . . 687026-10T . . . . . . . . . . . . . . 687026-12S . . . . . . . . . . . . . . 687026-12T . . . . . . . . . . . . . . 687026-15S . . . . . . . . . . . . . . 687026-15T . . . . . . . . . . . . . . 687028 . . . . . . . . . . . . . . . . . . 687030-3 . . . . . . . . . . . . . . . . 687030-4 . . . . . . . . . . . . . . . . 687030-6 . . . . . . . . . . . . . . . . 687066-12S . . . . . . . . . . . . . . 687066-12T . . . . . . . . . . . . . . 687066-15S . . . . . . . . . . . . . . 687066-15T . . . . . . . . . . . . . . 687070 . . . . . . . . . . . . . . . . . . 8
87200 . . . . . . . . . . . . . . 12, 1387202 . . . . . . . . . . . . . . 12, 1387204 . . . . . . . . . . . . . . . . . 1387212 . . . . . . . . . . . . . . . . . 1587214 . . . . . . . . . . . . . . . . . 1587216 . . . . . . . . . . . . . . 12, 1387218 . . . . . . . . . . . . . . . . . 1387228 . . . . . . . . . . . . . . 14, 1687239 . . . . . . . . . . . . . . 14, 1687240 . . . . . . . . . . . . . . 14, 1687400 . . . . . . . . . . . . . . . . . 1387402 . . . . . . . . . . . . . . 14, 1587403 . . . . . . . . . . . . . . 14, 1587405 . . . . . . . . . . . . . . . . . 1587406 . . . . . . . . . . . . . . 13, 1487407 . . . . . . . . . . . . . . 13, 1487413 . . . . . . . . . . . . . . . . . 1387414 . . . . . . . . . . . . . . . . . 1487416 . . . . . . . . . . . . . . 13, 1487417 . . . . . . . . . . . . . . 13, 1487418 . . . . . . . . . . . . . . 13, 1487419 . . . . . . . . . . . . . . 13, 1487421 . . . . . . . . . . . . . . . . . 1387423 . . . . . . . . . . . . . . . . . 1387601 . . . . . . . . . . . . . . . . . 2087610 . . . . . . . . . . . . . . . . . 2687611 . . . . . . . . . . . . . . . . . 2687617 . . . . . . . . . . . . . . . . . . 887618 . . . . . . . . . . . . . . . . . . 887806 . . . . . . . . . . . . . . . . . 2687817 . . . . . . . . . . . . . . . . . . 987818 . . . . . . . . . . . . . . . . . . 987823 . . . . . . . . . . . . . . . . . . 887824 . . . . . . . . . . . . . . . . . . 887825 . . . . . . . . . . . . . . . . . . 887828 . . . . . . . . . . . . . . . . . . 887851 . . . . . . . . . . . . . . . . . 1487852 . . . . . . . . . . . . . . . . . 1487862 . . . . . . . . . . . . . . . . . 2087865 . . . . . . . . . . . . . . . . . . 887885 . . . . . . . . . . . . . . . . . . 787886 . . . . . . . . . . . . . . . . . . 787887 . . . . . . . . . . . . . . . . . . 787888 . . . . . . . . . . . . . . . . . . 787889 . . . . . . . . . . . . . . . . . . 787895 . . . . . . . . . . . . . . . . . . 787896 . . . . . . . . . . . . . . . . . . 787897 . . . . . . . . . . . . . . . . . . 787905 . . . . . . . . . . . . . . . . . . 887915 . . . . . . . . . . . . . . . . . . 787918 . . . . . . . . . . . . . . . . . . 487919 . . . . . . . . . . . . . . . . . . 487920 . . . . . . . . . . . . . . . . . . 487934 . . . . . . . . . . . . . . . . . . 787935 . . . . . . . . . . . . . . . . . . 787936 . . . . . . . . . . . . . . . . . . 787937 . . . . . . . . . . . . . . . . . . 787938 . . . . . . . . . . . . . . . . . . 787939 . . . . . . . . . . . . . . . . . . 787940 . . . . . . . . . . . . . . . . . . 787941 . . . . . . . . . . . . . . . . . . 787942 . . . . . . . . . . . . . . . . . . 787955 . . . . . . . . . . . . . . . . . . 587956 . . . . . . . . . . . . . . . . . . 587957 . . . . . . . . . . . . . . . . . . 5
130021-3 . . . . . . . . . . . . . . . 9130067 . . . . . . . . . . . . . . . . 20130095 . . . . . . . . . . . . . . . . 13130117 . . . . . . . . . . . . . . . . 20130150LEE . . . . . . . . . . . . . 19130179 . . . . . . . . . . . . . 12, 13130200GEE . . . . . . . . . . . . 18130200KEE . . . . . . . . . . . . 18130201BCC . . . . . . . . . . . . 18130280 . . . . . . . . . . . . . . . . 12130300GEE . . . . . . . . . . . . 19130300KEE . . . . . . . . . . . . 19130332 . . . . . . . . . . . . . . . . 20130335 . . . . . . . . . . . . . . . . 20130500GEE . . . . . . . . . . . . 19236640 . . . . . . . . . . . . . . . . . 5236641 . . . . . . . . . . . . . . . . . 5236642 . . . . . . . . . . . . . . . . . 5236643 . . . . . . . . . . . . . . . . . 5236644 . . . . . . . . . . . . . . . . . 5236645 . . . . . . . . . . . . . . . . . 5243100 . . . . . . . . . . . . . 28, 30244727 . . . . . . . . . . . . . . . . 31247333 . . . . . . . . . . . . . . . . 29250176 . . . . . . . . . . . . . . . . 25250286 . . . . . . . . . . . . . . . . . 9250290 . . . . . . . . . . . . . . . . . 4250291 . . . . . . . . . . . . . . . . . 4250292 . . . . . . . . . . . . . . . . . 4250293 . . . . . . . . . . . . . . . . . 4250294 . . . . . . . . . . . . . . . . . 4250295 . . . . . . . . . . . . . . . . . 4250312 . . . . . . . . . . . . . . . . . 7250313 . . . . . . . . . . . . . . . . . 7250365 . . . . . . . . . . . . . 29, 30250400 . . . . . . . . . . . . . . . . 29250490 . . . . . . . . . . . . . . . . 29250500 . . . . . . . . . . . . . . . . 29250590 . . . . . . . . . . . . . . . . 29270982 . . . . . . . . . . . . . . . . 17271605 . . . . . . . . . . . . . . . . 17271606 . . . . . . . . . . . . . . . . 17274398 . . . . . . . . . . . . . . . . 31350241 . . . . . . . . . . . . . . . . 31350242 . . . . . . . . . . . . . . . . 31350244 . . . . . . . . . . . . . . . . 31350245 . . . . . . . . . . . . . . . . 31350282 . . . . . . . . . . . . . . . . 31350283 . . . . . . . . . . . . . . . . 31360675 . . . . . . . . . . . . . . . . . 9800019-5 . . . . . . . . . . . . . . 21800028-3 . . . . . . . . . . . . . . 21800031-3,5 . . . . . . . . . . . . . 22800037-1,2,3,4 . . . . . . . . . . 21800059-1,2 . . . . . . . . . . . . . 24800065-1 . . . . . . . . . . . . . . 22800066-2,3 . . . . . . . . . . . . . 22800100-2 . . . . . . . . . . . . . . 22800118-2 . . . . . . . . . . . . . . 22800131-5 . . . . . . . . . . . . . . 21800143-3 . . . . . . . . . . . . . . 22800192-3 . . . . . . . . . . . . . . 23800289-4,5 . . . . . . . . . . . . . 22800376-2 . . . . . . . . . . . . . . 22800469-2 . . . . . . . . . . . . . . 23
800621-4 . . . . . . . . . . . . . . 23800784-2 . . . . . . . . . . . . . . 23847400 . . . . . . . . . . . . . . . . 24874000 . . . . . . . . . . . . . . . . . 5876061 . . . . . . . . . . . . . . . . . 5876062 . . . . . . . . . . . . . . . . . 5876091 . . . . . . . . . . . . . . . . . 5876092 . . . . . . . . . . . . . . . . . 5876121 . . . . . . . . . . . . . . . . . 5876122 . . . . . . . . . . . . . . . . . 5876123 . . . . . . . . . . . . . . . . . 5876124 . . . . . . . . . . . . . . . . . 5876181 . . . . . . . . . . . . . . . . . 5876182 . . . . . . . . . . . . . . . . . 5876183 . . . . . . . . . . . . . . . . . 5876184 . . . . . . . . . . . . . . . . . 5876241 . . . . . . . . . . . . . . . . . 5876242 . . . . . . . . . . . . . . . . . 5876243 . . . . . . . . . . . . . . . . . 5876244 . . . . . . . . . . . . . . . . . 5880015-9 . . . . . . . . . . . . . . . 9880463 . . . . . . . . . . . . . . . . 25880466 . . . . . . . . . . . . . . . . 25880496 . . . . . . . . . . . . . . . . 25880511 . . . . . . . . . . . . . . . . . 9880513 . . . . . . . . . . . . . . . . . 9880514 . . . . . . . . . . . . . . . . . 9880515 . . . . . . . . . . . . . . . . . 9880517 . . . . . . . . . . . . . . . . . 9880518-9 . . . . . . . . . . . . . . . 9880519-9 . . . . . . . . . . . . . . . 9880550 . . . . . . . . . . . . . . . . 21880551 . . . . . . . . . . . . . . . . 21880552 . . . . . . . . . . . . . . . . 21880555 . . . . . . . . . . . . . . . . 25880556 . . . . . . . . . . . . . . . . 25880560 . . . . . . . . . . . . . . . . 21880561 . . . . . . . . . . . . . . . . 21882051 . . . . . . . . . . . . . . . . . 4882052 . . . . . . . . . . . . . . . . . 4882101 . . . . . . . . . . . . . . . . . 4882102 . . . . . . . . . . . . . . . . . 4882151 . . . . . . . . . . . . . . . . . 4882152 . . . . . . . . . . . . . . . . . 4882201 . . . . . . . . . . . . . . . . . 4882202 . . . . . . . . . . . . . . . . . 4882203 . . . . . . . . . . . . . . . . . 4882204 . . . . . . . . . . . . . . . . . 4882251 . . . . . . . . . . . . . . . . . 4882252 . . . . . . . . . . . . . . . . . 4882253 . . . . . . . . . . . . . . . . . 4882254 . . . . . . . . . . . . . . . . . 4882301 . . . . . . . . . . . . . . . . . 4882302 . . . . . . . . . . . . . . . . . 4882303 . . . . . . . . . . . . . . . . . 4882304 . . . . . . . . . . . . . . . . . 4882351 . . . . . . . . . . . . . . . . . 4882352 . . . . . . . . . . . . . . . . . 4882353 . . . . . . . . . . . . . . . . . 4882354 . . . . . . . . . . . . . . . . . 4882401 . . . . . . . . . . . . . . . . . 4882402 . . . . . . . . . . . . . . . . . 4882403 . . . . . . . . . . . . . . . . . 4882404 . . . . . . . . . . . . . . . . . 4
Viton® and Teflon® are registered trademarks of DuPont Performance Elastomers
A Complete Line of Lubrication Solutionsand Industrial Pumping Products
Our automated systems dispense measuredamounts of lubricant at predetermined intervals.Systems include Helios® and Duo-Matic™ two-linesystems, Centro-Matic®, Modular Lube® andQuicklub® as well as ORSCO precision oil lubrication.With our BearingSaver® program, we find the best automated solution for you from our wide range of systems for grease, fluid grease and oil.
Lincoln has developed specialized pumps and pumping stations to handle the difficult job of transferring thick fluids. Fromthe industry-best PileDriver III®
and PowerMaster III® pumpsand air motors to specialtypumps, controls and mountingaccessories, Lincoln is the preferred pumping system for many tough applications. Sometimes a simple
approach is the best solution. Our wide range of products includes smaller,self-contained automatedlubricators and general lubrication equipment.
Automated Lubrication
Industrial Pumping
General Lubrication
Whatever the service—evaluating your lubrication methods, installing a custom-engineered system, or supplying top-quality manual lubrication products—your Lincoln distributor makes certain you always get the very best value.
Systems House Distributors
Our systems house distributors offer the highest level of expertise available in the industry. They can custom design a system with the exact combination of Lincoln components you need. Then, they install the system in your plant with their knowledgeable technicians or work with your personnel to make sure the job is done correctly. Each distributor stocks a full inventory of pumps, metering devices, controllers, monitors and accessories. Each continues to meet our stringent requirements for product, systems and service knowledge. From Los Angeles to London, Boston to Bangkok, Lincoln’s top-of-the-industry systems house distributors will be there when and where you need them.
For the nearest authorized Lincoln sales and service representative, call:
Lincoln's global distribution networkis the best in the industry.Lincoln's global distribution network is the best in the industry.
MODULAR LUBE ®
AUTOMATED LUBRICATIONSYSTEMS
Lincoln Industrial Corp.One Lincoln WaySt. Louis, MO 63120-1578
Phone 314.679.4200Fax 314.679.4359www.lincolnindustrial.com
Form 442834 (12/05)© Copyright 2005Printed in U.S.A.
Americas:Lincoln Industrial Corp.One Lincoln WaySt. Louis, MO 631201.314.679.4200Fax: 1.314.679.4359Fax: 1.800.424.5359
Europe/Africa:Lincoln GmbH & Co. KGHeinrich-Hertz Strasse 2-8D-69190 WalldorfGermany49.6227.33.0Fax: 49.6227.33.259
Asia/Pacific:Lincoln Industrial Corporation51 Changi Business ParkCentral 2#09-06 The SignatureSingapore 48606665.6588.0188Fax: 65.6588.3438
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice