Modification of Laser Alignment of Cranial X-Rays Intraoperatively
Pamela Tebebi
Advisor: Peter Konrad, MD/PhD
Project Goal
Design an accurate sighting system by means of laser sighting alignment for the intraoperative X-ray taken of brain stimulator implants.
Problem Definition
Background of Deep Brain Stimulation (DBS) for Movement DisordersWhat is DBS?
– A surgical procedure whereby electrodes are permanently implanted in particular parts of the brain and continuous stimulation administered by a small electric unit (generator) that is implanted under the skin of the chest
– It is a way to control the abnormal activity of particular brain cells in the immediate vicinity of the stimulating electrode without destroying brain tissue
How will this help movement problems– Goals of DBS are to improve the control of movement
on the side opposite the stimulator– Depending on the type of movement disorder, this
may result in loss of tremor, loss of rigidity, loss of dyskinesia or dystonia
Background continued
Risk of DBS– Most serious is bleeding into the brain causing headache,
paralysis, coma, or death
– Infection (10%)
– Malfunction of stimulator
– Movement of the electrode
Significance of the Project
Want to design an accurate sighting system by means of laser sighting alignment for the intraoperative X-ray taken of brain stimulator implants.
True significance of taking an X-ray is to compare the stimulation site to the final site if implant so as to verify that the implant is still at the designated
Current DBS Device
Developed by FHC, Inc
(specialize in metal and glass microelectrode, needles and instrumentation for cellular research
Does not allow for alignment of
mT Platform is design from importing CT and MR scans into the mT Platform Planning Software which automatically designs a patient-customized adaptor to fiducial marker based stereotactic system that aligns the mT Platform Drive System to reach selected target
microTargeting Platform System (mT Platform)
Proposed Methods to Align X-ray : Method 1
– Attaching on fiducial markers can be cumbersome and affect stability of mT Platform
mT Platform
Fiducial
Proposed Methods to Align X-ray : Method 2
mT Platform
Location of fiducial
Mounting Hub
Positioner- aid in the path probe will travel to desired target
Alignment device
AC-PC line
Current Status
Waiting to here from Ron Franklin, senior engineer at FHC to determine how adaptable the new method would be to their mT Platform System
Work Completed
Research on other methods to align X-ray involve using mirror that can be rotated to hit desired target
Other methods involve using a collimated laser beam to mimic x-ray beam path
Current Work
Complete DesignSafe Analysis
Future Work
Set up appointment with Ron Franklin to determine if anymore adaptations to the device are necessary