MODELING OF BLOOD FLOW IN STENOSED ARTERY WITH A CLOT
JALILAH BINTI RUBAI
UNIVERSITI TEKNOLOGI MALAYSIA
Modeling of Blood Flow in Stenosed Artery with a Clot
JALILAH BINTI RUBAI
A dissertation submitted in partial fulfilment of the
requirement for the award of degree of
Master of Science (Engineering Mathematics)
Faculty of Science
Universiti Teknologi Malaysia
June 2014
iv
ACKNOWLEDGMENT
Foremost, I would like to express my sincere gratitude to my supervisor Prof. Dr.
Norsarahaida Binti Saidina Amin for her patience, motivation, enthusiasm, and
immense knowledge in guiding me to complete this dissertation.
I would like to thank my family for supporting me throughout my studies. Last but
not least to all my colleagues for their encouragement and understanding.
v
ABSTRACT
The presence of blood clot in the blood stream can lead to partial or even
complete blockage of the blood vessel. The condition can get worse in a stenosed
artery. The clot will alter the flow field and modify the pressure distribution. To
understand the changes in the blood flow due to presence of the clot, the fluid
mechanics of blood flow in a stenosed artery with a clot is studied through a
mathematical analysis. Blood is modelled as an incompressible Newtonian fluid and
the flow is treated to be axi-symmetric. The artery is modelled as a rigid tube with a
stenosis and an elongated shape representing a clot inside it. Both the stenosis and
the clot are axi-symmetric over the length of the artery. The governing equations of
motion are solved by using regular perturbation analysis. The results show that in
the presence of the clot, the important physiologically flow characteristics such as
pressure gradient and wall shear stress vary markedly across the stenotic lesion. The
height of the peak of the clot increases the wall shear stress. Results are sensitive to
not only the geometry of the stenotic wall but also to the position of the clot.
vi
ABSTRAK
Kehadiran darah beku di dalam aliran darah boleh menyebabkan salur darah
tersumbat separa atau tersumbat sepenuhnya. Keadaan boleh menjadi lebih buruk di
dalam arteri dengan stenosis. Gumpalan akan mengubah medan aliran dan
mengubah taburan tekanan. Untuk memahami perubahan dalam aliran darah
disebabkan kehadiran gumpalan, mekanik bendalir aliran darah dalam arteri yang
mengandungi gumpalan dikaji melalui analisis matematik. Darah dimodelkan
sebagai cecair Newtonian yang tidak boleh mampat dan aliran dianggap simetri
terhadap paksi. Arteri dimodelkan sebagai tiub yang rigid dengan stenosis dan
sebuah bentuk memanjang yang mewakili gumpalan di dalamnya. Stenosis dan
gumpalan adalah simetri terhadap paksi di sepanjang arteri. Persamaan-persamaan
kawalan gerakan diselesaikan dengan menggunakan analisa perturbasi biasa. Hasil
kajian menunjukkan bahawa dengan kehadiran gumpalan, ciri-ciri fisiologi aliran
yang penting seperti kecerunan tekanan dan tegasan ricih dinding berubah agak
ketara di seluruh kawasan stenosis. Ketinggian puncak gumpalan meningkatkan
tegasan ricih dinding. Keputusaan tidak hanya sensitif terhadap geometri dinding
stenosis, tetapi juga terhadap posisi gumpalan.
vii
TABLE OF CONTENTS
CHAPTER TITLE PAGE
DECLARATION ii
DEDICATION iii
ACKNOWLEDGEMENT iv
ABSTRACT v
ABSTRAK vi
LIST OF FIGURES ix
LIST OF SYMBOLS/NOTATIONS xi
LIST OF APPENDICES xiii
1 INTRODUCTION 1
1.1 Research Background 1
1.2 Problem Statement 2
1.3 Objectives of Study 3
1.4 Scope of Study 3
1.5 Significance of Study 4
2 LITERATURE REVIEW 5
2.1 Introduction 5
2.2 Anatomy of Blood Vessel 5
2.3 Physiology of Blood Flow 7
2.4 Stenosis and Blood Clot 10
viii
2.5 Studies on the Blood Flow in Artery 13
3 MATHEMATICAL FORMULATION 18
3.1 Introduction 18
3.2 Formulation of the Problem 19
3.3 Derivation of Continuity Equation 20
3.4 Cylindrical Continuity Equation 22
3.5 Derivation of Momentum Equation 23
3.6 Non-dimensionalisation of the Governing Equations 29
3.7 Boundary Conditions 33
4 SOLUTION PROCEDURE 34
4.1 Introduction 34
4.2 Series Solutions 35
4.3 Solution for )1(O at 0 37
4.4 Steady Streaming of )(O 43
5 RESULTS AND DISCUSSIONS 46
5.1 Introduction 46
5.2 The Equations of the Clot and Stenosis 47
5.3 Streamline Pattern 49
5.4 Pressure Gradient 52
5.5 Wall Shear Stress 53
5.6 Discussion 54
6 CONCLUSIONS AND SUGGESTION 56
6.1 Summary 56
6.2 Conclusions 57
6.3 Suggestion for Future Work 57
x
LIST OF FIGURES
FIGURE NO. TITLE PAGE
2.1 Blood vessels: Artery, capillary and vein 6
2.2: Blood vessels: The wall of an artery and vein 6
2.3 Velocity of blood flow changes throughout the systemic
circuit.Velocity changes according to the total crosssectional 9
2.4 Blood pressure changes throughout the systemic circuit
Blood pressure decreases with distance from the left ventricle 9
2.5a Stenosis in blood vessel 10
2.5b The forming of stenosis 10
2.6 The process of blood clotting 11
2.7 Schematic diagram of blood vessel and catheter 14
2.8 Schematic representation of a catheterized artery 14
2.9 The schematic diagram of the catheterized stenosed artery 15
2.10 The schematic diagram of the flow geometry corresponding
to a catheterized curved artery with stenosis 16
3.1 Diagram of the stenosed artery with a clot inside 19
3.2 Finite volume control fixed in space 20
3.3 Infinitesimally small, moving fluid element 24
4.1 Flowchart of solution porcedure 34
5.1 The Matlab coding to plot the clot and the stenosis model 47
5.2 The model of clot and stenosis with different value of zd.
(a) zd = 0 and (b) zd = 0.125 48
5.3 The steady streamline patterns for 2 = 0.2. = 5 and zd = 0 51
xi
5.4 The steady streamline patterns for 2 = 0.2, = 5 and zd = 0.125 51
5.5 Variation of induced pressure gradient '
sp along axial
direction for different values of 2 52
5.6 Variation of s along axial direction for different values of 2 53
xii
LIST OF SYMBOLS/NOTATIONS
Roman Letters
d - Diameter
f(z) - function describing wall variation
k - Catheter radius (ratio of catheter size to vessel size, 𝑘 𝑅𝑜 𝑅𝑜
l - Length
𝑝 - Dimensional pressure
p - Non-dimensional pressure
Q - Dimensional flow rate
q - Non-dimensional flow rate
𝑟 - Dimensional radial distance
r - Non-dimensional radial distance
𝑅𝑜 - Undisturbed/ mean radius of the stenosed artery
𝑅𝑠𝑡 - Steady streaming Reynolds number (𝑈𝑜2 𝜔𝜇 )
𝑅𝑒𝑛 - Reynolds number (𝑈𝑜𝑅𝑜 𝜇 )
𝑅𝑠 - Dimensional radius of stenosed artery
𝑟𝑠 - Non-dimensional radius of stenosed artery
𝑅𝑐 - Dimensional radius of clot artery
𝑟𝑐 - Non-dimensional radius of clot artery
𝑡 - Dimensional time
𝑈𝑜 - Characteristic axial velocity
(𝑈, 𝑊) - Dimensional velocity in (𝑟 , 𝑧 ) direction
(u,w) - Non-dimensional velocity in (𝑟, 𝑧) direction
𝑧 - Dimensional axial distance
z - Non-dimensional axial distance
xiii
𝐼𝑜 , 𝐾𝑜 - Modified Bessel‟s function of order 0
𝐼1, 𝐾1 - Modified Bessel‟s function of order 1
Greek Letters
α - Womersley number (𝑅𝑜 𝜔 𝜇 )
ρ - Density of the fluid
λ - Length of stenosis
δ - Geometric parameter 𝑅𝑜 𝜆
δ2 - Radius of peak of clot
θ - Dimensional azimuthal distance
ω - Angular frequency
μ - Kinematic viscosity
τ - Non-dimensional time
τo - Phase angle
ψ - Stream function
xiv
LIST OF APPENDICES
APPENDIX TITLE PAGE
A Bessel‟s Function and its Solutions 60
B Matlab Coding to Obtain the Modified Bessel‟s
Function of Order 0 and 1 66
CHAPTER 1
INTRODUCTION
1.1 Research Background
The medical term for a blood clot is a thrombus (pl. thrombi). When the
thrombus becomes larger, the shear forces that act on it also increase due to the
acceleration of blood around the thrombus. If the shear forces exceed the strength of
the inter-cellular/inter-molecular bonds, a portion of the thrombus can break off and
enter the circulation. A portion of the thrombus that breaks off of the main thrombus
is called a thromboembolus or embolus (pl. emboli). Emboli that enter the
circulation can have many devastating effects within the body. As they pass through
the circulatory system, it is possible that emboli with different sizes become lodged
in different sections of the cardiovascular system. This will reduce or completely cut
off the oxygen supply to the cells in that area. As a result, the part of the heart
muscle that is deprived of oxygen dies, and a heart attack can occur. If the emboli
become stuck in the cerebral circulation, a stroke can occur.
There are many situations in which a blood clot is more likely to form
including being on long-term bed rest, crossing legs for long periods of time when
sitting, or sitting for long periods of time, such as in a plane or car, during and after
2
pregnancy, not having enough water in body (dehydration), taking birth control pills
or estrogen hormones (especially in women who smoke) and using an intravenous
catheter long-term. Blood clots are also more likely in people with cancer, recent
surgery or injury, obesity, and liver or kidney disease. People who have high
cholesterol level are also at risk for blood clots. A build up of cholesterol that
narrows an artery may change or slow the flow of blood, making it easier for a blood
clot or thrombus to form. Conditions that are passed down through families
(inherited) may make you more likely to form abnormal blood clots. Inherited
conditions such as Factor V Leiden thrombophilia, Prothrombin G20210A mutation
and other rare conditions such as protein C, protein S, and antithrombin III
deficiencies which affect clotting can also make a person more likely to form
abnormal blood clots.
Blood clot can also enter the blood stream during the insertion of catheter into
the blood vessel. The catheter may cause a thrombus on the wall of the blood vessel
to break free and enter the blood circulation. There is also a risk of bringing
pathological constituents into the blood stream during the catheterization process.
The constituents that go inside the blood vessel will be attached to the vessel wall but
later some constituents can get detached from the wall, then join the blood stream
again, and form a clot that can lead to partial or even complete blockage of the blood
vessel. One example of the constituents is bacteria such as Coagulase negative
staphylococci. Coagulase negative staphylococci can produce an enzyme called
coagulase which can cause blood clot formation.
1.2 Problem Statement
In the previous research, most of the studies on blood flow in the arteries
involved the insertion of catheter and the existence of stenosis. Only a few of them
included clot formation in the blood vessel. The existence of blood clot in the blood
vessel especially in the stenosed artery will affect the blood flow. An annular region
3
will be formed in the blood vessel between the blood clot and the wall of the
stenosed blood vessel. Thus this research will investigate whether there are any
significant changes on the flow field due to the existence of clot inside the stenosed
artery.
1.3 Objectives of Study
The purpose of this study is to determine the blood flow characteristics such as
the pressure gradient and the wall shear stress in a stenosed artery when there is a
presence of a clot inside it. The objectives of the study are
a) to formulate a mathematical model to represent the flow of blood in the
annular region between a clot and a stenosed artery.
b) to solve the governing equations of the blood flow by using perturbation
method.
c) to investigate the effect of the clot on the blood flow in terms of pressure
gradient, wall shear stress and streamline pattern.
1.4 Scope of Study
This work is based on the journal paper by Sarkar and Jayaraman (2005)
titled „Nonlinear analysis of arterial blood flow: steady streaming effect‟. The
stenosis and the clot are assumed to be axi-symmetic over the length of the artery.
The flow is considered axi-symmetric and oscillatory in nature. The blood is
considered Newtonian and incompressible.
4
1.5 Significance of Study
The blood clot in the blood circulation can lead to partial or even complete
blockage of the blood vessels. The seriousness can be very acute in the case of a
stenotic artery. This study is significant to be carried out in order to understand the
seriousness of the situation by investigating the blood flow characteristic in the
artery. In reality, clot formation in blood vessel after the catheter insertion procedure
can lead to serious problems such as heart attack and stroke due to the blockage in
the blood vessel. Usually, after an insertion of catheter procedure into the blood
vessel, the doctor will likely recommend the patient to take aspirin and another
anticlotting medicine to prevent blood clot formation. So the investigation of blood
flow in stenosed artery together with blood clot is significance to be carried out.
58
REFERENCES
Anderson, J.R. (1995). Computational Fluid Dynamics; The Basics with
Applications. New York: McGraw-Hill.
Bell, W.W.(1968). Special Functions for Scientists and Engineers. New Jersey:
Princeton.
Chapra, S.C. and Canale R.P.(2010). Numerical Methods for Engineers. (6th
ed.).
New York: McGraw-Hill.
Dash, R.K., Jayaraman, G., Metha, K.N. (1996). Estimation of Increased Flow
Resistance In A Narrow Catheterized Artery; A Theoretical Model. J.
Biomech. 29(7): 917-930.
Dash, R. K., Jayaraman, G., Metha, K. N. (1999). Flow in a Catheterized Curved
Artery with Stenosis. J. Biomech 32: 49-61.
Doffin, J. and Chagneau, F. (1981). J. Oscillating flow between a clot model and a
stenosis. Biomech. 14 (3): 143-148.
Jayaraman, G. and Sarkar, A. (2005). Nonlinear Analysis of Arterial Blood Flow;
Steady Streaming Effect. Nonlinear Anal. 63: 880–890. 50
Kanai, H., Iizuka, M., Sakamoto, K. (1970). One of the problems in the measurement
of blood pressure by catheter-insertion; wave reflection at the tip of the
catheter. Medical and Biological Engineering: 483-496.
59
Ku, David N. (1997). Blood Flow In Arteries, Annu. Rev. Fluid Mech. 29:399–434.
Mader, Sylvia S.(2005). Understanding Human Anatomy & Physiology, McGraw-
Hill.
Martini, F.H., and Ober, W.C., Garrison, C.W., Welch, K., and Hutchings, R.T.
(2001). Fundamental of anatomy & Physiology. (5th
Ed.). Upper Saddle River,
N.J.: Prentice Hall.
McDonald, D.A. (1974). Blood Flow in Arteries. Baltimore: Williams & Wilkins.
Norzieha binti Mustapha (2009). Numerical Modelling and Simulation of Blood Flow
Through a Multi-Irregular Stenosed Artery. Universiti Teknologi Malaysia:
Dissertation Doctor of Philosophy.
Rubenstein David A., Frame Mary D., Wei Yin, (2012). Biofluid Mechanics: An
Introduction to Fluid Mechanics, Macrocirculation , and Microcirculation,
Elsevier.
Sarkar, A. and Jayaraman, G. (1998). Correction to Flow Rate Pressure Drop
Relation in Coronary Angioplasty: Steady Streaming Effect. J. Biomech 31:
781-791.
Srivastava, V.P., Vishnoi, R., Mishra. S., and Sinha, P. (2010). Blood Flow through a
composite stenosis in catheterized arteries. E-Journal of Science &
Technology. 4(5) 55 – 64.
White, F.M. (2003). Fluid Mechanics. McGraw Hill: New York.
Womersley JR. (1955). Method for the calculation of velocity, rate of flow and
viscous drag in arteries when their pressure gradient is known. J. Physiol.
127:553–63.