5
©2008 A+ Corporation, LLC. All rights reserved. SCC-33M-InsInstallationOperation_0508 An ISO 9001:2000 certified company Manufacturing Contact Information A+ Corporation, LLC 41041 Black Bayou Rd. Gonzales, LA 70737 Call for expert product application assistance: Phone: (225)-644-5255 Website: www.geniefilters.com Fax: (225)-644-3975 E-mail: [email protected] Safety Warnings ! Tools Required Model 33M Avenger™ Model 33M Installation & Operation Instructions Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death. For models containing Liquid Block™: Slowly open the supply pressure so that the minimum differential pressure required to ` shut-off the Liquid Block™ is not met or exceeded.. Valve off the sample flow before installation. ` Do not exceed any equipment pressure ratings. ` Four #10 screws for mounting bracket to panel. ` Screwdriver for mounting bracket to panel. `

Model 33M Avenger™ Model 33M Installation & Operation …soclema.com/wp-content/uploads/SOCLEMA_FILTRESGENIE... · 2017. 10. 25. · Install the mounting bracket onto the Avenger

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • ©2008 A+ Corporation, LLC. All rights reserved.SCC-33M-InsInstallationOperation_0508An ISO 9001:2000 certified company

    Manufacturing Contact InformationA+ Corporation, LLC41041 Black Bayou Rd.Gonzales, LA 70737

    Call for expert product application assistance:Phone: (225)-644-5255 Website: www.geniefilters.comFax: (225)-644-3975 E-mail: [email protected]

    Safety Warnings!

    Tools Required

    Model 33M

    Avenger™ Model 33M Installation & Operation Instructions

    Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death.For models containing Liquid Block™: Slowly open the supply pressure so that the minimum differential pressure required to shut-off the Liquid Block™ is not met or exceeded..Valve off the sample flow before installation. Do not exceed any equipment pressure ratings.

    Four #10 screws for mounting bracket to panel. Screwdriver for mounting bracket to panel.

  • ©2008 A+ Corporation, LLC. All rights reserved.

    Model 33M

    SCC-33M-InsInstallationOperation_0508An ISO 9001:2000 certified company 2

    Technical Specifi cations

    DimensionsBack View Side View

    3.000”

    4.420”

    2.875”3.592””

    0.544”

    4.670”

    2.250”

    4.670” 4.223”

    1.414”

    2.000”Dia.

    Port D

    5.144”

    Minimum Maintenance Clearance 8.250”

    OPTIONALMOUNTINGBRACKET

    Maximum pressure rating 1,000 psigMaximum recommended Lowest possible pressure consistent with application supply pressure

    Maximum temperature 185 °F (85 °C) for Type 5 membrane

    302 °F (150 °C) for Hi-Flow Backed membrane

    Port sizes Inlet, Outlet, & Bypass: 1/2” female NPTGauge: 1/4” female NPT

    Internal volume 200 cc

    Wetted materials Machined parts : 316 stainless steel / NACE compliant All other metal parts: stainless steel / NACE compliant Sealing material: Viton® standard Membrane: inert

    Number of ports 5

    Element size

    Maximum recommended 4,000 cc/min for Type 5 membrane membrane flow rate 9,000 cc/min for Hi-Flow Backed membrane

    *Maximum flow results in approximately 2 psi membranedifferential pressure

    (For higher flow rates contact the factory)

    Outside Diameter: ~ 1.4”Inside Diameter: ~ 1.0”Length: ~ 2.5”

    Maximum Liquid Block™ 85 psig**Slowly open the supply pressure so that the minimum differential pressure required to shut-off the Liquid Block™ is not met or exceeded.

    valve auto-reset pressure

  • ©2008 A+ Corporation, LLC. All rights reserved.

    Model 33M

    SCC-33M-InsInstallationOperation_0508An ISO 9001:2000 certified company 3

    Installation InstructionsInstall the mounting bracket onto the Avenger Model 33M or 38M as per the Mounting Bracket Installation Instructions included in A+ Corporation Mounting Bracket Kit P/N 33-509SS for Model 33M or P/N 38-509SS for Model 38M. Aftermarket brackets may be mounted as per the mounting diagrams below. Mount the Avenger horizontally as shown in the diagram. Lock washers may be used on the lower 10-32 screws to tilt the filter as shown to ensure that liquids drain properly. “Port D” should be facing down as shown. An optional downstream pressure gauge may be installed in “Port E” or it may be plugged. The Model 33M has 1/2” NPT ports (except for the 1/4” NPT gauge “Port E”) and the Model 38M has 1/4” NPT ports. Refer to the “Application” for tubing connection instructions.

    Application Drawing

  • ©2008 A+ Corporation, LLC. All rights reserved.

    Model 33M

    SCC-33M-InsInstallationOperation_0508An ISO 9001:2000 certified company 4

    Application Drawing

  • Model 33M

    An ISO 9001:2000 certified company Genie, ® Avenger,TM Liquid BlockTM and Genie® Membrane TechnologyTM are trademarks or registered

    trademarks of A+ Corporation, LLC. All other referenced trademarks are the property of their respective owners.

    Model Numbering & Additional Part Numbers

    !

    Your model number is determined by your specific needs. Choose options below.

    Sealing material

    Membrane type 5 = Type 5 7 = Hi-Flow Backed

    Mounting bracket accessory Part # = 33-509-SS (sold separately)

    How to build the model number:

    Sealing materialElement typeMembrane typeLiquid Block™ option

    33M 3/2 S How to build the replacement o-ring kit number:

    Sealing material

    33M 5 0

    How to build the replacement membrane kit number:

    Membrane type

    33M 5 0 How to build the replacement filter element number:

    Element type

    30 5

    Element type 07CFS = 0.1 micron coalescer fluorocarbon SS10 = 10 micron stainless steel

    Liquid Block™ Blank = No Liquid Block™ L = Liquid Block™

    0 = Viton® 1 = Kalrez® (other materials available upon request) !

    !

    We cannot recommend specific sealing materials due to the complex nature of sample stream compositions. Temperature and pressure also may be factors. Unless specified otherwise, the product will ship with our standard sealing materials and materials of construction stated in the technical specifications section of the corresponding Product Sheet. Please refer to www.dupontelastomers.com for sealing material recommendations and advice. It is the user’s responsibility to specify the sealing materials and other materials of construction for their application.

    !

    ! !