Upload
kamal-arab
View
179
Download
14
Embed Size (px)
DESCRIPTION
ge device summary
Citation preview
SIZE DWG NO SH REV
A4 105T3815 1 D TBFT-TMP-FR-GTE-0060- Rev : 001
Ce document, proprit exclusive de
GE Energy Products France SNC est strictement confidentiel. Il ne
peut tre communiqu, copi ou
reproduit sans notre autorisation crite pralable.
This document, exclusive property of
GE Energy Products France SNC is strictly confidential.
It must not be communicated, copied or
reproduced without our prior written consent. First made for : 9171E MLI : 0414
UNLESS OTHERWISE SPECIFIED NAMES DATE
GE Power & Water
Thermal Products
DIMENSIONS ARE IN MM [INCHES]
TOLERANCES ON:
1 [2] PL DECIMALS +
2 [3] PL DECIMALS +
ANGLES +
FRACTIONS +
DRAWN
J.M. Bardine27/08/12
CHECKED
T. Helfer27/08/12
APPROVED
E. Panarotto27/08/12
NOMENCLATURE DES APPAREILS DE CONTROLE
DIAGRAM. SCHEMA. P.P. DEVICE SUMMARY
WEIGHT : 0000 kg SIZE
A4
CAGE CODE DWG NO
105T3815INDEX
SCALESHEET 1/1
Doc. Source : TBFT-ISP-FR-GTE-0020
Attention : Dont modify this document without any update of the database P414.
Attention : Ne pas modifier ce document sans mise jour de la base P414.
ISO PROJECTION
EACH SECTION SHALL BE REVISED IN
ITS ENTIRETY.
ALL SHEETS OF EACH SECTION ARE
THE SAME REVISION LEVEL AS
INDICATED IN THE REVISION
BLOCK
SECTION NO. OF
SHEETS
REV
INDEX 1 D
01EN 31 D
01FR 31 D
REVISIONS
REV DESCRIPTION NAMES DATE SIGNATURES
- First issue
J.M. Bardine
27/08/2012T. Helfer
E. Panarotto
AECR0015665
(DCI12003387)
J.M. Bardine
12/10/2012T. Helfer
E. Panarotto
BECR0016828
(DCI12003808)
J.M. Bardine
21/02/2013T. Helfer
E. Panarotto
C ECR0025546
J.M. Bardine
18/04/2013L. Renier
E. Panarotto
D ECR0028594
J.M. Bardine
20/06/2013T. Helfer
E. Panarotto
DWG Number 105T3815 Rev D Released 6/24/2013 Page 1 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 1 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 1/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
REVISIONS
Rev Description
-First issue
A
- MLI PID 0416 : Addition of devices 23QT-3A,3B,4A,4B.
- MLI PID 0424 : Addition of devices PF1 and 71FF-1 to 6, removal of device FF2-2
- MLI PID 0425 : Addition of devices 88AB-1, 20AA-18, VA18-1, VPR18-1, removal of devices 65VA-18,
96VA-18
- MLI PID 0426 : Removal of devices SLI-1,2
- MLI PID 0436 : Addition of devices 20TK-90, 63TK-90
- MLI PID 0434 : Addition of device PSV500
- MLI PID 0494 : Removal of device PFA-6
B
- MLI PID 0424 : Addition of devices 20PF-100 33PF-1 VP-1
- MLI PID 0436 : Addition of devices 23HA-14,15,16
- MLI PID 0494 : Removal of devices 71FA-30,31 and addition of device 96FA-30
C
- MLI PID 0424 : PF1 : Characteristics modification
Addition of devices 20LF-SP-1,96LFSP,VA70-1
D- MLI PID 0424 : Addition of device VCK6-1
DWG Number 105T3815 Rev D Released 6/24/2013 Page 2 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 2 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 2/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
PRESSURE : All pressures are gauge pressure, abs means absolute pressure.
Abbreviations Descriptions
AA Atomizing Air
ACF Control Filter Downstream Pressure
AD Compressor Discharge Air
AE Extraction Air
AMF Lube Oil Filter Downstream Pressure
DEC. Decreasing
DPDT Double pole, double throw
DPG Differential Pressure Gauge
FC Fail safe to close
FO Fail open
GF Gas Fuel
GFV Gas Fuel Vent
GPL Gas Valve Stem Packaging Leakoff
INC. Increasing
LVDT Linear variable differential transformer
MLI
Model List Item : four digit code used by General Electric to identify
components, assembly, drawings or specifications, example : MLI 0414 for
Device Summary
NC Normally closed
NO Normally open
NormalMeans absolute zero energy level, such as no power, no oil, no speed, no
temperature
OD Oil Drain
ODOil drain above oil tank level
ODOil drain below oil tank level
OH Control Oil High Pressure
OHT Trip Oil High Pressure
OL Lube Oil
OLV Lube Oil Event
OR Regulated Lube Oil
PC Piping connecting point
SafetyA cross in the column means the device belongs to a safety loop related to
human safety. Do not modify devices or settings of any safety loop.
Slope The arrow direction indicates the liquid gravitational drainage due to the slope
SPDT Single pole, double throw
SPST Single pole, single throw
WD Water Drain
WF Water Feed
WR Water Return
DWG Number 105T3815 Rev D Released 6/24/2013 Page 3 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 3 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 3/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
Wiring diagram Description
ACCY The device is in the accessories wiring diagram (MLI 401A)
AIR The device is in the cooling fan module wiring diagram (MLI A132)
AIR DRY The device is in the air dryer module wiring diagram (MLI 1049)
CHROM The device is in the chromatograph module wiring diagram (MLI G023)
CLEAN The device is in the cleaning module wiring diagram (MLI E026)
CO2 The device is in the CO2 fire protection module wiring diagram (MLI A068)
ENCL-G The device is in the gas enclosure interface drawing (MLI 1195)
ENCL-LFThe device is in the liquid fuel / atomizing air / water injection module enclosure interface drawing (MLI
1152)
ENCL-LO The device is in the lube oil / fuel gas module enclosure interface drawing (MLI 1137)
ENCL-T The device is in the turbine enclosure interface drawing (MLI 1113)
ENCL-V The device is in the ventilation enclosure interface drawing (MLI 1643)
ENCL-WI The device is in the water injection enclosure interface drawing (MLI 1196)
FILT The device is in the air filter wiring diagram (MLI A040)
FG-SSOV The device is in the fuel gas, SSOV & vent module wiring diagram (MLI G064)
GAS The device is in the gas module wiring diagram (MLI 0991, A116 or 401G)
GAS HEAT The device is in the gas heating and treatment system wiring diagram (MLI G025)
GENE The device is in the generator wiring diagram
HEAT TR The device is in the interconnection pipes wiring diagram (MLI 0969)
IBH The device is in the bleed heating wiring diagram (MLI A037)
LF-AA The device is in the liquid fuel / atomizing air module wiring diagram (MLI A162)
LF-AA-WI The device is in the liquid fuel / atomizing air / water injection module wiring diagram (MLI A162)
LF-SR The device is in the liquid fuel recirculation skid wiring diagram (MLI 969S)
LF-TR The device is in the liquid fuel treatment skid wiring diagram (MLI E020)
LF-FD The device is in the liquid fuel flow devider wiring diagram (MLI 0613)
LF-H The device is in the liquid fuel heater wiring diagram (MLI E041)
LF-TPH The device is in the liquid fuel transfert pump&heating skid wiring diagram (MLI E047)
LF-PH The device is in the liquid fuel pump&heating skid wiring diagram (MLI A245)
LF-FT-PR The device is in the liquid fuel flow totalizer & pression regulation skid wiring diagram (MLI A246)
LO FG The device is in the lube oil / fuel gas module wiring diagram (MLI A160)
LOAD The device is in the load gear wiring diagram (MLI A012)
MIST The device is in the mist eliminator outline drawing (MLI A098)
OIL The device is in the lube oil wiring diagram (MLI 0990 or 401H)
STEAM The device is in the steam injection module wiring diagram (MLI A135)
TURB The device is in the gas turbine wiring diagram (MLI 401T)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 4 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 4 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 4/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
TURN-GEAR The device is in the turning gear wiring diagram (MLI A073)
VAN The device is in the additive injection vanadium module wiring diagram (MLI E021)
WASH The device is in the water washing module wiring diagram (MLI E025)
WI The device is in the water injection module wiring diagram (MLI A035)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 5 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 5 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 5/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
System NameMLI
P&IDSystem Reference Rev
Fuel Gas Filtration and Stop Valve G044 GFF N/A
Electrical Enclosure Equipment System 0403 0403 N/A
Control Devices Turbine System 0415 CD 209D7171 B
Lube Oil System 0416 LO 104T0837 -
Cooling and Sealing Air System 0417 CSA 227D1589 B
Instrument Air System 0419 APU N/A
Cooling Water System 0420 CW 227D2477 A
Starting Means System 0421 SM 205D4866 D
Gas Fuel System 0422 GF 227D1797 F
Liquid Fuel System 0424 LF 227D1699 C
Atomizing Air System 0425 AA 227D1582 B
Fire Protection System 0426 FP 105T2446 B
Air Extraction System 0428 AE N/A
Steam Injection System 0431 SI N/A
Inlet Air heating System 0432 IAR N/A
Hydraulic Supply System 0434 HS 219D2886 C
Heating and Ventilation System 0436 HV 105T2447 A
Turbine and Compressor Cleaning System 0441 TCC 227D2484 B
Turbine and Compressor Washing System 0442 TCW 227D2436 A
Water Injection System 0462 WI 104T0138 -
Compressor Inlet Guide Vanes System 0469 IGV 219D1732 A
Inlet and Exhaust System 0471 IE 105T2838 -
Gas Detection System 0474 GD 105T2451 -
Fuel Purge System 0477 FPU 219D1141 B
Gas Fuel Process System 0482 GFPS N/A
Nitrogen Injection System 0491 NI N/A
Performance Monitor System 0492 PM 103T6259 -
Additive Injection System 0494 LFAD 106T5319 A
Interconnections Lines System 0969 IL N/A
DWG Number 105T3815 Rev D Released 6/24/2013 Page 6 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 6 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 6/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0425 20AA-18 0922 ACCYSolenoid valve for VA18-1 control
Characteristics : Normal : 1 to 3 open ; 2 closed | 0,035 kW | 125 VDC
0425 20AB-1 0922 ACCYSolenoid valve for VA22-1 control
Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC
0417 20CB-1 1071 TURBCompressor bleed solenoid valve
Characteristics : Normal : B to C Open, A closed | 0.04 kW | 125 VDC
0424 20CF-1 0510 ACCYFuel pump clutch solenoid
Characteristics : Normal : NO | 125 VDC | 0.16 kW (max)
0422 20FGC-1 0509 GAS Trip solenoid valve for gas control valve (VGC-1)
Characteristics : Normal : NO | 0.0156 kW | 125 VDC
0422 20FGS-1 0507 GAS Fuel gas stop valve solenoid valve
Characteristics : Normal : NO | 0.0156 kW | 125 VDC
0424 20FL-1 0511 ACCY Liquid fuel stop valve solenoid
Characteristics : Normal : NC | 0.02 kW | 125 VDC
0441 20KF-1 E026 CLEANVAKF-1 valve solenoid
Characteristics : Normal : NC | 0.002 kW | 230 VAC | 50 Hz
0441 20KF-2 E026 CLEANVAKF-2 valve solenoid
Characteristics : Normal : NC | 0.002 kW | 230 VAC | 50 Hz
0441 20KF-3 E026 CLEANVAKF-3 valve solenoid
Characteristics : Normal : NC | 0.002 kW | 230 VAC | 50 Hz
0424 20LF-SP-1 0992 ACCYPressure control solenoid valve
Characteristics : Normal : NO | 0.035 kW | 125 VDC
0424 20PF-100 0961 TURBPurge fuel liquid solenoid valve
Characteristics : Normal : A to P open. B closed | 0.04 kW | 110 to 125V DC
0477 20PG-1 0991 GAS
Solenoid valve for VA13-1 control
Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC
Settings : A needle-valve is installed upstream of 20PG-1 in order to adjust VA13-1 time
opening at 30 seconds
0477 20PG-2 0991 GASSolenoid valve for VA13-2 control
Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC
0477 20PL-1 918T TURBSolenoid valve for VA19-1 control
Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC
0436 20TK-90 1605 ENCL-T
Electromagnet, air inlet filtering system by pass door double 88TK enclosure
Characteristics : 0.09 kW | 24 VDC
Settings : Electromagnet energized, door closed.
0421 20TU-1 0605 ACCYTorque converter fill / drain solenoid valve
Characteristics : Normal : NC
0469 20TV-1 0548 TURBSolenoid valve for compressor IGV trip system
Characteristics : Normal : NO | 0.1 kW | 125 VDC
0442 20TW-1 0953 TURBMotor valve off-line compressor water wash
Characteristics : 230 VAC | Normal : NC | 50 Hz | 0.072 kW
0442 20TW-2 0983 TURBMotor valve turbine water wash
Characteristics : 230 VAC | Normal : NC | 50 Hz | 0.072 kW
0442 20TW-3 0953 TURBMotor valve on-line compressor water wash
Characteristics : 230 VAC | Normal : NC | 50 Hz | 0.072 kW
0422 20VG-1 0991 GASFuel gas vent solenoid valve
Characteristics : Normal : FO | 0.009 kW | 125 VDC
0477 20VG-2 0991 GASGas fuel purge vent solenoid valve
Characteristics : Normal : NO | 0.125 kW | 125 VDC
0422 20VG-7 G064 FG-SSOVvent 3 ways solenoid valve
Characteristics : Normal : NC | 0.0106 kW | 125 VDC
DWG Number 105T3815 Rev D Released 6/24/2013 Page 7 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 7 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 7/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0422 20VG-8 G064 FG-SSOV Fuel gas vent solenoid valve
Characteristics : Normal : FO | 0,012 kW | 125 VDC
0422 20VS4-4 G064 FG-SSOV Gas stop valve VS4-4 solenoid valve
Characteristics : Normal : FO | 0,012 kW | 125 VDC
0462 20WN-1 A035 WIWater injection stop valve solenoid valve
Characteristics : Normal : NO | 0.0112 kW | 125 VDC
0462 20WN-18 A035 WIVS2-4 solenoid valve
Characteristics : Normal : NO | 0.0048 kW | 125 VDC
0462 20WN-2 A035 WIWater injection stop valve solenoid valve (part of VS2-2)
Characteristics : Normal : NO | 0.0112 kW | 125 VDC
0420 20WN-30 0963 TURBSolenoid valve for fuel check valves cooling water
Characteristics : Normal : NO | 0.0112 kW | 125 VDC
0425 23AB-1 1047 ACCYAnti-condensation heater for motor 88AB-1
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0436 23BT-1 1605 ENCL-TAnti-condensation heater for motor 88BT-1
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0436 23BT-2 1605 ENCL-TAnti-condensation heater for motor 88BT-2
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0421 23CR-1 0603 ACCYAnti-condensation heater for motor 88CR-1
Characteristics : 50 Hz | 230 VAC | 0.18 kW
0421 23CR-2 0603 ACCYAnti-condensation heater for motor 88CR-1
Characteristics : 50 Hz | 230 VAC | 0.18 kW
0421 23CR-3 0603 ACCYAnti-condensation heater for motor 88CR-1
Characteristics : 50 Hz | 230 VAC | 0.18 kW
0436 23HA-11 1658 ENCL-GGas compartment heater
Characteristics : 50 Hz | 400 VAC | 3.9 kW
0436 23HA-12 1658 ENCL-GGas compartment air inlet heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0436 23HA-13 1658 ENCL-GGas compartment air inlet heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0436 23HA-14 1658 ENCL-GGas compartment air inlet heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0436 23HA-15 1658 ENCL-GGas compartment air inlet heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0436 23HA-16 1658 ENCL-GGas compartment air inlet heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0436 23HA-30 1113 ENCL-TAuxiliaries compartment heater
Characteristics : 50 Hz | 400 VAC | 15 kW
0434 23HQ-1 0628 ACCYAnti-condensation heater for motor 88HQ-1
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0436 23HT-30 1113 ENCL-TTurbine compartment heater
Characteristics : 50 Hz | 400 VAC | 20 kW
0416 23QA-1 1006 ACCYAnti-condensation heater for motor 88QA-1
Characteristics : 50 Hz | 230 VAC | 0.1 kW
0416 23QT-1A 0938 ACCYImmersion heater # 1 lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QT-1B 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QT-2A 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
DWG Number 105T3815 Rev D Released 6/24/2013 Page 8 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 8 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 8/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0416 23QT-2B 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC |3 kW
0416 23QT-3A 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QT-3B 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QT-4A 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QT-4B 0938 ACCYImmersion heater lube oil tank
Characteristics : 50 Hz | 400 VAC | 3 kW
0416 23QV-1A A098 MISTAnti-condensation heater for motor 88QV-1A
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0421 23TG-1 0603 ACCY88TG-1 motor anti-condensation heater
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0417 23TK-1 1233 AIRAnti-condensation heater for motor 88TK-1
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0417 23TK-2 A132 AIRAnti-condensation heater for motor 88TK-2
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0436 23VG-1 1605 ENCL-TAnti-condensation heater for motor 88VG-1
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0436 23VG-2 1605 ENCL-TAnti-condensation heater for motor 88VG-2
Characteristics : 50 Hz | 230 VAC | 0.05 kW
0462 23WN-1 A035 WIAnti-condensation heater for motor 88WN-1
Characteristics : 50 Hz | 230 VAC | 0.1 kW
0436 23WR-30 1196 ENCL-WIWater injection skid enclosure heater
Characteristics : 50 Hz | 400 VAC | 9 kW
0415 28FD-10 1121 TURB Flame detector combustion chamber n10
0415 28FD-11 1121 TURB Flame detector combustion chamber n11
0415 28FD-4 1121 TURB Flame detector combustion chamber n4
0415 28FD-5 1121 TURB Flame detector combustion chamber n5
0415 30SG-1 1213 TURBIgnition transformer alarm relay
Characteristics : Normal : NO
0436 33BT-1 1605 ENCL-T
GT compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0436 33BT-2 1605 ENCL-T
GT compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0417 33CB-1 1022 TURB
Bleed valve limit switch (11th stage)
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0417 33CB-2 1022 TURB
Bleed valve limit switch (11th stage)
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0417 33CB-3 1022 TURB
Bleed valve limit switch (11th stage)
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0417 33CB-4 1022 TURB
Bleed valve limit switch (11th stage)
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
DWG Number 105T3815 Rev D Released 6/24/2013 Page 9 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 9 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 9/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0436 33DT-1 1605 ENCL-T
Auxiliaries compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-11 1658 ENCL-G
Load compartment door limit switch gas compartment
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-12 1658 ENCL-G
Load compartment door limit switch gas compartment
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-13 1658 ENCL-G
Gas compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-14 1658 ENCL-G
Gas compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-2 1605 ENCL-T
Auxiliaries compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-3 1605 ENCL-T
Turbine compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0436 33DT-4 1605 ENCL-T
Turbine compartment door limit switch
Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
0424 33FL-1 0511 ACCY
Liquid fuel stop valve limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0436 33FV-1 1605 ENCL-T
Liquid fuel compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0436 33FV-2 1605 ENCL-T
Liquid fuel compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0436 33JS-1 1659 ENCL-WI
Water injection skid enclosure : ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0436 33JS-2 1659 ENCL-WI
Water injection skid enclosure : ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0441 33KF-11 E026 CLEAN
Cleaning skid VAKF-1 valve limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0441 33KF-21 E026 CLEAN
Cleaning skid VAKF-2 valve limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0441 33KF-31 E026 CLEAN
Cleaning skid VAKF-3 valve limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0441 33KF-32 E026 CLEAN
Cleaning skid VAKF-3 valve limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0424 33PF-1 0961 TURB
Purge fuel liquid valve limit switch VP-1
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
DWG Number 105T3815 Rev D Released 6/24/2013 Page 10 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 10 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 10/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0477 33PG-1 0991 GAS
VA13-1 close position limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0477 33PG-2 0991 GAS
VA13-1 open position limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0477 33PG-3 0991 GAS
VA13-2 close position limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0477 33PG-4 0991 GAS
VA13-2 open position limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0421 33TC-1 0605 ACCY
Torque converter solenoid valve limit switch
Characteristics : Normal : NO
Settings : 20TU-1 de-energized : switch activated, contact closed
0442 33TFD-1 1026 TURB
False start drain valve limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0421 33TM-5 0605 ACCY
Torque converter low torque limit switch
Characteristics : Normal : NO, switch closed for IGV closed or max torque
Settings : Setup at 3 tr of handwheel (full scale 0-242 tr)
0421 33TM-6 0605 ACCY
Torque converter high torque limit switch
Characteristics : Normal : NO, switch closed for IGV closed or max torque
Settings : Setup at 242 tr of handwheel (full scale 0-242 tr)
0436 33VG-1 1605 ENCL-T
Load compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0422 33VG-11 0991 GAS
Gas system vent valve limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0436 33VG-2 1605 ENCL-T
Load compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0422 33VG-21 G064 FG-SSOV
VA13-17 limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0422 33VG-22 G064 FG-SSOV
VA13-17 limit switch
Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed
0422 33VG-8 G064 FG-SSOV
Gas fuel vent valve VA13-18 limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
0422 33VG-9 G064 FG-SSOV
Gas fuel vent valve VA13-18 limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0436 33VL-1 1658 ENCL-G
Gas compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0436 33VL-2 1658 ENCL-G
Gas compartment ventilation damper limit switch
Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
0422 33VS4-4 G064 FG-SSOV
Fuel gas stop valve (VS4-4) limit switch
Characteristics : Normal : NO
Settings : Valve opened : limit switch activated, contact closed
DWG Number 105T3815 Rev D Released 6/24/2013 Page 11 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 11 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 11/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0422 33VS4-5 G064 FG-SSOV
Fuel gas stop valve (VS4-4) limit switch
Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
0462 33WN-1 A035 WI
Water injection control valve limit switch (part of VC4-1)
Characteristics : Normal : NO
Settings : Valve full opened : limit switch activated, contact closed
0462 33WN-11 A035 WI
VS2-4 valve limit switch
Characteristics : Normal : NO
Settings : Valve full opened : limit switch activated, contact closed
0462 33WN-2 A035 WI
Water injection control valve limit switch (part of VC4-1)
Characteristics : Normal : NO
Settings : Valve full closed : limit switch activated, contact closed
0462 33WN-3 A035 WI
Water injection stop valve limit switch (part of VS2-1)
Characteristics : Normal : NO
Settings : Valve full opened : limit switch activated, contact closed
0462 33WN-4 A035 WI
Water injection stop valve limit switch (part of VS2-1)
Characteristics : Normal : NO
Settings : Valve full closed : limit switch activated, contact closed
0415 39V-1A 1218 TURB Vibration sensor
Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak
0415 39V-1B 1218 TURB Vibration sensor
Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak
0415 39V-2A 1218 TURB Vibration sensor
Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak
0415 39V-3A 1218 TURB Vibration sensor
Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak
0415 39V-3B 1218 TURB Vibration sensor
Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak
0415 39VS-11 235A TURB
Vibration sensor bearing #1
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-12 235A TURB
Vibration sensor bearing #1
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-21 235B TURB
Vibration sensor bearing #2
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-22 235B TURB
Vibration sensor bearing #2
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-23 235B TURB
Vibration sensor
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-24 235B TURB
Vibration sensor
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-31 235C TURB
Vibration sensor
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 39VS-32 235C TURB
Vibration sensor
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 12 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 12 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 12/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0426 43CP-1 1113 ENCL-TBreak glass unit auxiliaries compartment access door
Characteristics : Normal : NO
0426 43CP-2 1113 ENCL-TBreak glass unit GT compartment access door
Characteristics : Normal : NO
0426 43CP-3 1153 ENCL-TBreak glass unit auxiliaries compartment access door
Characteristics : Normal : NO
0426 43CP-4 1113 ENCL-TBreak glass unit GT compartment access door
Characteristics : Normal : NO
0426 43CP-5 1113 ENCL-TBreak glass unit load compartment access door
Characteristics : Normal : NO
0426 43CP-6 1195 ENCL-GBreak glass unit gas compartment access door
Characteristics : Normal : NO
0426 43CP-7 1195 ENCL-GBreak glass unit gas compartment access door
Characteristics : Normal : NO
0426 45FA-10A 1113 ENCL-T
Thermostatic fire detector oil pit auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-10B 1113 ENCL-T
Thermostatic fire detector oil pit auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-11A 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-11B 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-12A 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-12B 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-13A 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-13B 1113 ENCL-T
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-1A 1104 ACCY
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-1B 1104 ACCY
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-2A 1104 ACCY
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-2B 1104 ACCY
Thermostatic fire detector auxiliaries compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-6A 0991 GAS
Thermostatic fire detector gas compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 13 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 13 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 13/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0426 45FA-6B 0991 GAS
Thermostatic fire detector gas compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-7A 0991 GAS
Thermostatic fire detector gas compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FA-7B 0991 GAS
Thermostatic fire detector gas compartment
Characteristics : Normal : NO
Settings : Closed : 163 14C (325 25F)
0426 45FS-1A 1104 ACCY Fire detector - Liquid fuel skid
Characteristics : Normal : NO
0426 45FS-1B 1104 ACCY Fire detector - Liquid fuel skid
Characteristics : Normal : NO
0426 45FS-2A 1104 ACCY Fire detector - Liquid fuel skid
Characteristics : Normal : NO
0426 45FS-2B 1104 ACCY Fire detector - Liquid fuel skid
Characteristics : Normal : NO
0426 45FT-1A 1103 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-1B 1103 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-2A 1154 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-2B 1154 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-3A 1154 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-3B 1154 TURB
Thermostatic fire detector GT compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-8A 1160 TURB
Thermostatic fire detector load compartment
Characteristics : Normal : NO
Settings : Closed : 385 14C (725 25F)
0426 45FT-8B 1160 TURB
Thermostatic fire detector load compartment
Characteristics : Normal : NO
Settings : Closed : 385 14C (725 25F)
0426 45FT-9A 1160 TURB
Thermostatic fire detector load compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0426 45FT-9B 1160 TURB
Thermostatic fire detector load compartment
Characteristics : Normal : NO
Settings : Closed : 316 14C (600 25F)
0474 45HA-4 1658 ENCL-G Gas detector gas module compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
0474 45HA-5 1658 ENCL-G Gas detector gas module compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
0474 45HA-6 1658 ENCL-G Gas detector gas module compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
DWG Number 105T3815 Rev D Released 6/24/2013 Page 14 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 14 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 14/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0474 45HT-4 1605 ENCL-T Gas detector turbine compartment turbine compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
0474 45HT-5 1605 ENCL-T Gas detector turbine compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
0474 45HT-6 1605 ENCL-T Gas detector turbine compartment ventilation duct
Characteristics : Range : 0 - 20% LEL
0436 49HA-12 1658 ENCL-G
Security thermostat gas compartment heater
Characteristics : Normal : NC
Settings : Opened at 98C +0/-16C (208,4F +0/-61F)
0471 63CA-1 A040 FILT
GT compressed air inlet filter low pressure switch
Characteristics : Normal : NO
Settings :
Not adjustable : increase close at : 6 0.5 bar (87 7.25 psi) |
Decrease open at : 5.5 0.5 bar (79.77 7.25 psi)
0422 63FG-1 0991 GAS
Gas fuel pressure switch
Characteristics : Normal : NC
Settings :
Decrease close at : 1.03 0.05 bar (15.0 0.75 psi) |
Not adjustable : increase open at : 1,31 0,2 bar (19 3 psi)
0422 63FG-2 0991 GAS
Gas fuel pressure switch
Characteristics : Normal : NC
Settings :
Decrease close at : 1.03 0.05 bar (15.0 0.75 psi) |
Not adjustable : increase open at : 1,31 0,2 bar (19 3 psi)
0441 63KF-1 E026 CLEAN
Cleaning skid pressure switch
Characteristics : Normal : NC
Settings : Decreased closed at : 0.1 0.01 bar (1.5 0.15 psi)
0477 63PG-1 0991 GAS
Pressure switch on VA13-1 & VA13-2 intervalves space
Characteristics : Normal : NC
Settings : Not adjustable : decrease close at : 3.17 0.21 bar (46 3 psi) | Increase open
at : 3.45 0.14 bar (50 2 psi)
0477 63PL-21 918T TURB
Pressure switch on liquid fuel purge air
Characteristics : Normal : NO
Settings : Not adjustable : increase close at : 6 0.3 bar (87 4 psi) | Decrease open at :
4.6 0.3 bar (67 4 psi)
0416 63QA-2 0557 ACCY
Low lube oil pressure alarm
Characteristics : Normal : NO
Settings :
Not adjustable : increase close at : 3.1 0.14 bar (45 2 psi) |
Decrease open at : 2.8 0.07 bar (40.6 1 psi)
0416 63QT-2A ALT. GENE
Generator bearing low lube oil pressure
Characteristics : Normal : NO
Settings :
Not adjustable : increase close at : 0.62 0.035 bar (9 0.5 psi) |
Decrease open at : 0.55 0.021 bar (8 0.3 psi)
0471 63TF-2A A040 FILT
GT inlet air system differential pressure switch
Characteristics : Normal : NC
Settings :
Increase open at : 21 0.5 mbar (0.3 0.007 psi)
0471 63TF-2B A040 FILT
GT inlet air system differential pressure switch
Characteristics : Normal : NC
Settings :
Increase open at : 21 0.5 mbar (0.3 0.007 psi)
0417 63TK-1A053/A
132AIR
Turbine exhaust frame cooling pressure switch
Characteristics : Normal : NO
Settings :
Closed above 381 19 mm H2O (15 0.75 in H2O)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 15 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 15 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 15/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0417 63TK-2A053/A
132AIR
Turbine exhaust frame cooling pressure switch
Characteristics : Normal : NO
Settings :
Closed above 381 19 mm H2O (15 0.75 in H2O)
0436 63TK-90 1605 ENCL-T
Differential pressure switch air inlet double 88TK enclosure
Characteristics : Normal : NO
Settings :
Increase closed at : 1 0.1 mbar (0.015 0.001 psi)
0462 63WN-1 A035 WI
Water injection pressure switch
Characteristics : Normal : NC
Settings : Open on decreasing pressure / atm : -0.270 0.01 bar (-3.9 0.14 psi)
0462 63WN-2 A035 WI
Water injection pressure switch
Characteristics : Normal : NO
Settings : Open on decreasing pressure : 36 bar 0,7 bar (522 10 psi)
0462 63WN-3 A035 WI
Water injection differential pressure switch on water injection pump filter
Characteristics : Normal : NC
Settings : Open on increasing differential pressure : 1.03 bar 0.1 bar (15 1 psi)
0424 65FP 0533 ACCY Liquid fuel pump (by pass valve) servo valve
0422 65GC-1 0509 GAS Gas control valve servo valve (VGC-1)
0424 71FF-1 0910 ACCY
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high level
0424 71FF-2 0910 ACCY
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high level
0424 71FF-3 0910 ACCY
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high level
0424 71FF-4 969L TURB
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high level
0424 71FF-5 969L TURB
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high-high level
0424 71FF-6 969L TURB
Fuel leakage detection pot level switch
Characteristics : Normal : NC
Settings : Opening on high-high level
0416 71QT-1 1038 ACCY
Very low level lube oil tank detector
Characteristics : Normal : NO
Settings : Decrease open on low level at 510 5 mm of floating device stroke
0424 77FD-1 0910 ACCYFlow divider magnetic pickup-speed
Settings : Gap : 0.23 0.025 mm (0.009 0.001 in)
0424 77FD-2 0910 ACCYFlow divider magnetic pickup-speed
Settings : Gap : 0.23 0.025 mm (0.009 0.001 in)
0415 77HT-1 0546 TURB Speed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
0415 77HT-2 0546 TURB Speed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
0415 77HT-3 0546 TURB Speed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
0415 77NH-1 0546 TURBSpeed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 16 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 16 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 16/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0415 77NH-2 0546 TURBSpeed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
0415 77NH-3 0546 TURBSpeed sensor
Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)
0415 77RP-11 235A TURB
Keyphasor
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0425 88AB-1 1047 ACCYAtomizing air booster motor
Characteristics : 15 kW | 3000 rpm | 27.5A | 50 Hz | 400 VAC
0436 88BT-1 1605 ENCL-TCooling air fan motor - acoustical enclosure GT compartment
Characteristics : 37 kW | NC | 50 Hz | 400 VAC
0436 88BT-2 1605 ENCL-TCooling air fan motor - acoustic enclosure GT compartment
Characteristics : 37 kW | NC | 50 Hz | 400 VAC
0421 88CR-1 0603 ACCYElectrical cranking motor
Characteristics : 1000 kW | 3000 rpm | 102 A | 50 Hz | 6.6 kV
0494 88FA-30E021/E0
48VAN
Electric motor of PFA-30 pump
Characteristics : 0.46 kW | 1500 rpm | 3.5A | 50 Hz | 230 VAC
0494 88FA-31E021/E0
48VAN
Electric motor of PFA-31 pump
Characteristics : 0.55 kW | 1380 rpm | 1.60 A | 50 Hz | 400 VAC
0494 88FA-32E021/E0
48VAN
Electric motor of PFA-32 pump
Characteristics : 0.55 kW | 1380 rpm | 1.60 A | 50 Hz | 400 VAC
0494 88FA-6 E048 VANElectric motor of mixer of tank 501BA
Characteristics : 0.37 kW | 1500 rpm | 1.10 A | 50 Hz | 400 VAC
0424 88FM 0613 ACCYFlow divider starting motor
Characteristics : 0.37 kW | 1400 rpm | 50 Hz | 400 VAC
0436 88FV-1 1605 ENCL-TCooling air fan motor liquid fuel compartment
Characteristics : 4 kW | 1500 rpm | 50 Hz | 400 VAC
0436 88FV-2 1605 ENCL-TCooling air fan motor liquid fuel compartment
Characteristics : 4 kW | 1500 rpm | 50 Hz | 400 VAC
0434 88HQ-1 0628 ACCYAuxiliary hydraulic supply pump motor
Characteristics : 15 kW | 1500 rpm | 28.2A | 50 Hz | 400 VAC
0436 88JS-1 1659 ENCL-WIWater injection skid enclosure cooling air fan motor
Characteristics : 0.37 kW | 1500 rpm | 50 Hz | 400 VAC
0436 88JS-2 1659 ENCL-WICooling air fan motor water injection skid enclosure
Characteristics : 0.37 kW | 1500 rpm | 50 Hz | 400 VAC
0416 88QA-1 1006 ACCYAuxiliary lube oil pump motor
Characteristics : 90 kW | 3000 rpm | 149,5A | 50 Hz | 400 VAC
0416 88QE-1 1007 ACCYEmergency lube oil pump motor
Characteristics : 9 kW | 1750 rpm | 89A | 125 VDC
0416 88QV-1A A098 MISTLube oil mist eliminator motor
Characteristics : 18.5 kW | 3000 rpm | 32.8A | 50 Hz | 400 VAC
0421 88TG-1 0538 ACCYTurning gear electrical motor
Characteristics : 30 kW | 750 rpm | 61 | 50 Hz | 400 VAC
0417 88TK-11233/A
132AIR
Turbine exhaust frame cooling blower & motor
Characteristics : 45 kW | 3000 rpm | 79A | 50 Hz | 400 VAC
0417 88TK-21233/A
132AIR
Turbine exhaust frame cooling blower & motor
Characteristics : 45 kW | 3000 rpm | 79A | 50 Hz | 400 VAC
0421 88TM-1 0605 ACCYTorque adjuster drive motor
Characteristics : 1.5 kW | 3000 rpm | 4 A | 50 Hz | 400 VAC
DWG Number 105T3815 Rev D Released 6/24/2013 Page 17 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 17 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 17/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0436 88VG-1 1605 ENCL-TCooling air fan motor acoustic enclosure load compartment
Characteristics : 18.5 kW | 1500 rpm | 50 Hz | 400 VAC
0436 88VG-2 1605 ENCL-TCooling air fan motor acoustic enclosure load compartment
Characteristics : 18.5 kW | 1500 rpm | 50 Hz | 400 VAC
0436 88VL-1 1658 ENCL-GCooling air fan motor gas module acoustic enclosure
Characteristics : 4 kW | 1500 rpm | 50 Hz | 400 VAC
0436 88VL-2 1658 ENCL-GCooling air fan motor gas module acoustic enclosure
Characteristics : 4 kW | 1500 rpm | 50 Hz | 400 VAC
0462 88WN-1 A035 WIWater injection pump motor
Characteristics : 75 kW maxi | 3000 rpm | 50 Hz | 400 VAC
0422 90SR-1 0507 GAS Gas speed ratio/stop valve servo valve
0469 90TV-1 0548 TURB Servovalve, compressor IGV actuator
0462 90WN-1 A035 WI
Electro-pneumatic converter
Settings :
04 0.20 mA for 0 bar (0 psi)
20 0.20 mA for 2.6 bar (37.7 psi)
0436 95BT-1 1605 ENCL-T
Air flow control (anemometer) for turbine enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
0436 95BT-2 1605 ENCL-T
Air flow control (anemometer) for turbine enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
0436 95BT-3 1605 ENCL-T
Air flow control (anemometer) for turbine enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
0415 95SG-13 1213 TURBIgnition transformer for 95SP-13
Characteristics : 0.15 kVA | 50 Hz | 15 kV | 230 VAC
0415 95SG-14 1213 TURBIgnition transformer for 95SP-14
Characteristics : 0.15 kVA | 50 Hz | 15 kV | 230 VAC
0415 95SP-13 1214 TURB Spark plug for combustion chamber n13
0415 95SP-14 1214 TURB Spark plug for combustion chamber n14
0436 95VL-1 1658 ENCL-G
Air flow control (anemometer) for gas skid enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
0436 95VL-2 1658 ENCL-G
Air flow control (anemometer) for gas skid enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
0436 95VL-3 1658 ENCL-G
Air flow control (anemometer) for gas skid enclosure
Characteristics : 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
fan running and doors closed : x1 mA, adjust the speedtronic constant software at a
value equivalent to { [60% * (x1 - 4) ] + 4 mA }
DWG Number 105T3815 Rev D Released 6/24/2013 Page 18 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 18 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 18/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0425 96AA-4A 557T TURB
Atomizing air manifold pressure transmitter
Settings :
04 0,05 mA for -1 bar (-14.5 psi)
20 0,1 mA for 35 bar (507.6 psi)
0425 96AA-4B 557T TURB
Atomizing air manifold pressure transmitter
Settings :
04 0,05 mA for -1 bar (-14.5 psi)
20 0,1 mA for 35 bar (507.6 psi)
0425 96AA-4C 557T TURB
Atomizing air manifold pressure transmitter
Settings :
04 0,05 mA for -1 bar (-14.5 psi)
20 0,1 mA for 35 bar (507.6 psi)
0425 96AD-1 0557 ACCY
Atomizing air main compressor differential pressure transmitter
Characteristics : 10.5 to 36 V CC
Settings :
04 0.02 mA for 0 bar (0 psi)
20 0.1 mA for 6 bar (87 psi)
0492 96AP-1A 557T TURB
Pressure transmitter
Settings :
04 0.02 mA for 0.745 bar abs (22 in of Hg)
20 0.10 mA for 1.250 bar abs (36.9 in of Hg)
0492 96AP-1B 557T TURB
Pressure transmitter
Settings :
04 0.02 mA for 0.745 bar abs (22 in of Hg)
20 0.10 mA for 1.250 bar abs (36.9 in of Hg)
0492 96AP-1C 557T TURB
Pressure transmitter
Settings :
04 0.02 mA for 0.745 bar abs (22 in of Hg)
20 0.10 mA for 1.250 bar abs (36.9 in of Hg)
0492 96BD-1 557T TURB
Differential pressure transmitter between the air inlet of GT and the bell of GT intake
Settings :
04 0.02 mA for 0.000 bar (0.000 in of H2O)
20 0.10 mA for 0.345 bar (138.5 in of H2O)
0417 96CD-1A 0557 ACCY
Compressor discharge pressure transmitter
Characteristics : 10.5 to 36 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.05 mA for 21 bar (304.5 psi)
0417 96CD-1B 0557 ACCY
Compressor discharge pressure transmitter
Characteristics : 10.5 to 36 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.05 mA for 21 bar (304.5 psi)
0417 96CD-1C 0557 ACCY
Compressor discharge pressure transmitter
Characteristics : 10.5 to 36 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.05 mA for 21 bar (304.5 psi)
0492 96CS-1 557T TURB
Differential pressure transmitter between the air inlet of GT and the bell of GT intake
Settings :
04 0.02 mA for 0 mbar (0 in of H2O)
20 0.10 mA for 27.4 mbar (11 in of H2O)
0494 96FA-1E021/E0
48VAN
Vanadium inhibitor flow transmitter
Characteristics : Nominal 7 W / maxi 11 W | Between 85 and 265 V ac
Settings :
04 0.05 mA for 0 l/h
20 0.1 mA for 80 l/h (0.35 gpm)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 19 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 19 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 19/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0494 96FA-30 E048 VAN
Level transmitter on principal vanadium inhibitor tank
Settings :
04 0,05 mA for 50 mm
20 0,1 mA for 800 mm
0422 96FG-1 0991 GAS
Inlet gas fuel module pressure transmitter
Characteristics : 12 to 45 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 34.5 bar (500 psi)
0422 96FG-2A 0991 GAS
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 34.5 bar (500 psi)
0422 96FG-2B 0991 GAS
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 34.5 bar (500 psi)
0422 96FG-2C 0991 GAS
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 34.5 bar (500 psi)
0424 96FL-2 0992 ACCY
Liquid fuel module inlet relative pressure transmitter
Settings :
04 0.05 mA for 0 bar(0 psi)
20 0.1 mA for 10 bar (145 psi)
0436 96FV-30A 0557 ACCY
Differential pressure transmitter between liquid fuel enclosure and auxiliaries
compartment
Settings :
04 0.05 mA for 0 Pa (0 psi)
20 0.1 mA for 100 Pa (0.0145 psi)
0436 96FV-30B 0557 ACCY
Differential pressure transmitter between liquid fuel enclosure and auxiliaries
compartment
Settings :
04 0.05 mA for 0 Pa (0 psi)
20 0.1 mA for 100 Pa (0.0145 psi)
0436 96FV-30C 0557 ACCY
Differential pressure transmitter between liquid fuel enclosure and auxiliaries
compartment
Settings :
04 0.05 mA for 0 Pa (0 psi)
20 0.1 mA for 100 Pa (0.0145 psi)
0422 96GC-1,2 0509 GAS
Fuel gas control valve (VGC-1) LVDT
Settings :
0.7 0.1 V = 0% open |
3.5 0.5 V = 100% open
0474 96HA-4 1195 ENCL-G
Gas detector transmitter
Characteristics : 0,0065 kW | 24 VDC (mini = 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
0474 96HA-5 1195 ENCL-G
Gas detector transmitter
Characteristics : 0.0065 KW | 24 VDC (mini : 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
DWG Number 105T3815 Rev D Released 6/24/2013 Page 20 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 20 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 20/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0474 96HA-6 1195 ENCL-G
Gas detector transmitter
Characteristics : 0.0065 KW | 24 VDC (mini : 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
0434 96HF-1 0557 ACCY
Hydraulic oil filter differential pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 7 bar (101.5 psi)
0434 96HQ-1 0557 ACCY
Hydraulic oil supply pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 160 bar (2320 psi)
0474 96HT-4 1113 ENCL-T
Gas detector transmitter
Characteristics : 0.0065 kW | 24 VDC (mini : 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
0474 96HT-5 1113 OTHER
Gas detector transmitter
Characteristics : 0.0065 kW | 24 VDC (mini : 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
0474 96HT-6 1113 ENCL-T
Gas detector transmitter
Characteristics : 0.0065 kW | 24 VDC (mini : 18 VDC)
Settings :
04 0.04 mA for 0% of the LEL
20 0.2 mA for 20% of the LEL
0424 96LF-7 0992 ACCY
Liquid fuel HP filter differential pressure transmitter
Settings :
04 0.05 mA for 0 bar
20 0.1 mA for 7 bar(102 psi)
0424 96LFSP 0992 ACCY
Main liquid fuel line pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 85 bar (1232 psi)
0416 96QA-2 0926 ACCY
Lube oil system VPR-2 inlet pressure transmitter
Characteristics : 10.5 to 36 VDC
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 7 bar (101.5 psi)
0416 96QE-2 0557 ACCY
Emergency pump discharge pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 2 bar (29 psi)
0416 96QL-1 1038 ACCY
Lube oil tank level transmitter
Settings :
04 0,1 mA for 760 mm (29.9 in)of floating device stroke
20 04 0,1 mA for 130 mm (5.12 in) of floating device stroke
The stroke of floating device is measured between the flange and the axis of floating
device
0416 96QQ-21 0557 ACCY
Main lube oil filter pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 4 bar (58 psi)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 21 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 21 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 21/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0416 96QQ-22 0557 ACCY
Main lube oil filter pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 4 bar (58 psi)
0416 96QQ-8 0557 ACCY
Torque converter filter differential pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 1.72 bar (25 psi)
0416 96QT-2B ALT. GENE
Low lube oil pressure transmitter generator
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for 1.72 bar (25 psi)
0416 96QV-1 0557 ACCY
Tank s air vacuum differential pressure transmitter
Settings :
04 0.05 mA for 0 bar (0 psi)
20 0.1 mA for -15 mbar (-0.22 psi)
0471 96RH A040 FILT
Dew point and temperature transmitter
Characteristics : 230 VAC
Settings :
Output 1 :
04 0.05 mA for -50C (-58 F)
20 0.05 mA for +50C (122 F)
Output 2 :
04 0.05 mA for 0% RH
20 0.05 mA for 100 % RH
0422 96SR-1,2 0507 GAS
Stop ratio fuel gas (VSR-1) LVDT
Settings :
0.7 0.1 V = 0% open |
3.5 0.5 V = 100% open
0471 96TF-1 A040 FILT
Differential pressure transmitter of total filtration stages
Settings :
04 0.05 mA for 0 mmH2O (0 inH2O)
20 0.1 mA for 254 mmH2O (10 inH2O)
0421 96TM-1 0605 ACCY
Torque converter IGV position transmitter
Settings :
04 0.05 mA for 0 tr of handwheel (full scale 0-242 tr)
20 0.05 mA for 242 of handwheel (full scale 0-242 tr)
0469 96TV-1 0548 TURBLVDT (Linear variable displacement transmitter), compressor IGV actuator
Settings : 0.7 0.01 VAC for 34 IGV angle
0469 96TV-2 0548 TURBLVDT (Linear variable displacement transmitter), compressor IGV actuator
Settings : 0.7 0.01 VAC for 34 IGV angle
0415 96VC-11 235A TURB
Vibration transducer bearing #1
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0415 96VC-12 235A TURB
Vibration transducer bearing #1
Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)
0422 96VM-1 0639 OTHER
Gas mass flow transmitter
Characteristics : 0.011 kW | 230 UPS
Settings :
04 0.05 mA for 0 kg/s (0 lbm/s)
20 0.1 mA for 10 kg/s (22 lbm/s)
0462 96WF-1 A035 WI
Flow transmitter
Characteristics : 24 VDC 15%
Settings :
04 0.2 mA for 3.3 m3/h (14.4 gpm)
20 0.2 mA for 33 0.1 m3/h (145.3 0.44 gpm)
DWG Number 105T3815 Rev D Released 6/24/2013 Page 22 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 22 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 22/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0425 AAT-1A 637T TURBAtomizing air precooler air discharge thermocouple
Characteristics : Type K
0425 AAT-2A 637T TURBAtomizing air precooler air discharge thermocouple
Characteristics : Type K
0434 AH1-1 0908 N/A
Control oil hydraulic accumulator
Characteristics : 17.8 l (4.7 gal) | Nitrogen
Settings : 51.7 1 bar (750 15 psi)
0422 AH1-3 0991 N/A
Control oil hydraulic accumulator
Characteristics : 17.8 l (4.70 gal) | Nitrogen
Settings : 51.7 1 bar (750 15 psi)
0494 AH7-1E021/E0
48N/A
Accumulator on dosing pumps outlet
Characteristics : 0.5 l | Nitrogen
Settings : 3.3 bar (47.8 psi)
0436 AT-AC-1 1113 ENCL-TThermocouple accessory compartment
Characteristics : Type K
0436 AT-AC-11 1195 ENCL-GThermocouple gas compartment
Characteristics : Type K
0471 AT-ID-1 A040 FILTTemperature sensor inside the inlet air filter
Characteristics : Platinum PT100 | 100 Ohm at 0C (32F) | 0.385 Ohm/C (0.214 Ohm/F)
0471 AT-ID-2 A040 FILT
Temperature sensor
Characteristics : Platinum PT100 | 100 Ohm at 0C (32F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0471 AT-ID-3 A040 FILT
Temperature sensor
Characteristics : Platinum PT100 | 100 Ohm at 0C (32F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0436 AT-LC-1 637T TURB
Air temperature load compartment
Characteristics : Platinum PT100 | 100 Ohm at 0C (32F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0436 AT-TC-1 637T TURB
Air temperature turbine compartment
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0436 AT-TC-2 1113 ENCL-TThermocouple : turbine compartment enclosure
Characteristics : Type K
0436 AT-TC-3 1113 ENCL-TThermocouple : turbine compartment enclosure
Characteristics : Type K
0436 AT-WI-1 1659 ENCL-WIWater injection compartment temperature water injection compartment
Characteristics : Type K
0415 BT-J1-1A,1B 235A TURBDual thermocouple temperature journal bearing n1
Characteristics : Type K
0415 BT-J1-2A,2B 235A TURBDual thermocouple temperature journal bearing n1
Characteristics : Type K
0415 BT-J2-1A,1B 235B TURBDual thermocouple temperature journal bearing n2
Characteristics : Type K
0415 BT-J2-2A,2B 235B TURBDual thermocouple temperature journal bearing n2
Characteristics : Type K
0415 BT-J3-1A,1B 235C TURBDual thermocouple temperature journal bearing n3
Characteristics : Type K
0415 BT-J3-2A,2B 235C TURBDual thermocouple temperature journal bearing n3
Characteristics : Type K
0415 BT-TA1-2A,2B 235A TURBDual thermocouple temperature pad n2 of thrust bearing n1
Characteristics : Type K
DWG Number 105T3815 Rev D Released 6/24/2013 Page 23 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 23 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 23/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0415 BT-TA1-5A,5B 235A TURBDual thermocouple temperature pad n5 of thrust bearing n1
Characteristics : Type K
0415 BT-TA1-8A,8B 235A TURBDual thermocouple temperature pad n8 of thrust bearing n1
Characteristics : Type K
0415 BT-TI1-2A,2B 235A TURBDual thermocouple temperature pad n2 of counter thrust bearing n1
Characteristics : Type K
0415 BT-TI1-5A,5B 235A TURBDual thermocouple temperature pad n5 of counter thrust bearing n1
Characteristics : Type K
0415 BT-TI1-9A,9B 235A TURBDual thermocouple temperature pad n9 of counter thrust bearing n1
Characteristics : Type K
0425 CA1 0607 N/AMain atomizing air compressor
Characteristics : Centrifugal | 2.7 kg/s | Gear box shaft speed: 6600 rpm
0425 CA2 1047 N/ABooster atomizing air compressor
Characteristics : Volumetric | 510 m3/h (2245.46 gal/min) | 4000 rpm
0415 CT-DA-1 637T TURBThermocouple compressor air discharge temperature
Characteristics : Type K
0415 CT-DA-2 637T TURBThermocouple compressor air discharge temperature
Characteristics : Type K
0415 CT-IF-1 637T TURBThermocouple temperature compressor air inlet
Characteristics : Type K
0415 CT-IF-2 637T TURBThermocouple temperature compressor air inlet
Characteristics : Type K
0492 CT-IF-3/R 637T TURB
Resistance temperature detector
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-11/R 0603 ACCY
Cranking motor stator Ph1 temperature sensor 1
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-12/R 0603 ACCY
Cranking motor stator Ph1temperature sensor 2
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-21/R 0603 ACCY
Cranking motor stator Ph2 temperature sensor 1
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-22/R 0603 ACCY
Cranking motor stator Ph2 temperature sensor 2
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-31/R 0603 ACCY
Cranking motor stator Ph3 temperature sensor 1
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0421 ET-CRS-32/R 0603 ACCY
Cranking motor stator Ph3 temperature sensor 2
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0477 FA3-1 918T N/ALiquid fuel purge air filter
Characteristics : 5 m
0417 FA6 0909 N/AFilter on actuation air of bleed valve
Characteristics : 5 m
0417 FA7 0931 N/A5th stage extraction air moisture separator
Characteristics : 5 m
0462 FA8-2 A035 N/AWater injection air filter
Characteristics : 5 m
DWG Number 105T3815 Rev D Released 6/24/2013 Page 24 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 24 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 24/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0424 FD1-1 0613 N/A
Flow divider
Characteristics : type lineare, 7 elements with double pumps | 883 l/min (233 gpm) at
1650 rpm | 50 Hz
0424 FF2-1 1014 N/AHP fuel filter
Characteristics : Beta 40 = 75
0494 FF31-1E021/E0
48N/A
Filter before the pumps
Characteristics : Mesh = 0.91 mm
0422 FG-2 G064 N/AInstrumentation gas filter
Characteristics : 60 m
0434 FH2-1 1051 N/AHydraulic oil supply filter
Characteristics : Beta 3 > 200
0434 FH2-2 1051 N/AHydraulic oil supply filter
Characteristics : Beta 3 > 200
0424 FH3 0992 N/AHydraulic filter liquid fuel servo valve (control)
Characteristics : 40 m
0469 FH6-1 0548 N/AFilter, hydraulic fluid supply , IGV controller assembly
Characteristics : Beta 15 = 75
0422 FH7-1 0507 N/AServo hydraulic supply filter of stop ratio valve (VSR)
Characteristics : 15 m abs
0422 FH8-1 0509 N/AGas fuel control valve (VGC) servo hydraulic fluid supply filter
Characteristics : 15 m abs
0462 FM1-1 A035 N/AWater injection flowmeter
Characteristics : 3.27 m3/h (14.4 gpm) | 27.9 m3/h (122.8 gpm)
0424 FT-FI-1 0992 ACCYUpstream flow-divider liquid fuel temperature
Characteristics : Type K
0422 FTG-1 G064 FG-SSOVGas temperature measure / GT start permissive
Characteristics : Type T
0422 FTG-2 G064 FG-SSOVGas temperature measure / GT start permissive
Characteristics : Type T
0422 FTG-3 G064 FG-SSOVGas temperature measure / GT start permissive
Characteristics : Type T
0462 FW1-1 A035 N/AHigh pressure filter
Characteristics : Beta 13 = 75
0462 FW1-2 A035 N/AWater injection upstream pump Y strainer
Characteristics : Filtering media 800m
0421 HM-1 0605 N/ATorque converter and reversing gear
Characteristics : Driven at about 3000 rpm
0469 HM3-1 0548 N/AActuator assembly, inlet guide valve system
Characteristics : Actuator operation limits : 31.5 0.5 to 87.75 0.25
0425 HX1-1 1003 N/A Atomizing air precooler
0416 LOF1-1 1010 N/ALube oil filter
Characteristics : Beta 40 = 75
0416 LOF1-2 1010 N/ALube oil filter
Characteristics : Beta 40 = 75
0416 LOHX-1 1001 N/A Lube oil cooler
0416 LOHX-2 1001 N/A Lube oil cooler
0416 LT-B1D-1 637T TURBLube oil thermocouple #1 bearing drain
Characteristics : Type K
DWG Number 105T3815 Rev D Released 6/24/2013 Page 25 of 63
GE Proprietary Information - Class II (Internal) US EAR - NLR
SIZE DWG NO SH REV
A4 105T3815 25 D TBFT-TMP-FR-GTE-0060 Rev : 001
GE Power & Water
Thermal Products
SIZE
A4
CAGE CODE DWG NO
105T3815
SECTION 01EN
SCALE SHEET 25/ 31
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel
Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.
This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
It must not be communicated, copied or reproduced without our previous written consent.
MLI
PIDDevices MLI
Wiring
DiagramSafety Designation
0416 LT-B2D-1 637T TURBLube oil thermocouple #2 bearing drain
Characteristics : Type K
0416 LT-B3D-1 637T TURBLube oil thermocouple #3 bearing drain
Characteristics : Type K
0416 LT-BT1D-1 637T TURBLube oil thermocouple #1 bearing thrusts drain
Characteristics : Type K
0416 LT-G1D-1 ALT. GENELube oil thermocouple generator and load gear #1 bearing drain
Characteristics : Type K
0416 LT-G2D-1 ALT. GENELube oil thermocouple generator and load gear #2 bearing drain
Characteristics : Type K
0416 LT-OT-1 1218 ACCY
Temperature in oil tank detector
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0416 LT-OT-2 1218 ACCY
Resistance temperature in oil tank detector
Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) |
0.385 Ohm/C (0.214 Ohm/F)
0416 LT-TH-1 637A ACCYLube oil temperature turbine header thermocouple
Characteristics : Type K
0416 LT-TH-2 637A ACCYLube oil temperature turbine header thermocouple
Characteristics : Type K
0416 LT-TH-3 637A ACCYLube oil temperature turbine header thermocouple
Characteristics : Type K
0422 MG1 0512 N/A Gas fuel nozzle
0424 PF1 0611 ACCY
Main fuel pump
Characteristics : Positive displacement screw pump | 2924 rpm | 68.9 bar (1000 psi) |
870.5 l/min (230 gpm)
0494 PFA-30E021/E0
48N/A
Unloading pump
Characteristics : Centrifugal pump | 25 l/min (6.6 gpm)
0494 PFA-31E021/E0
48N/A
Dosing pump
Characteristics : Volumetric pump | 1500 rpm | 10 bar (145 psi) | 0 to 80 l/h (0 to 0.35
gpm)
0494 PFA-32E021/E0
48N/A
Dosing pump
Characteristics : Volumetric pump | 1500 rpm | 10 bar (145 psi) | 0 to 80 l/h (0 to 0.35
gpm)
0434 PH1 0627 N/AMain hydraulic supply pump
Characteristics : Volumetric pump | 1422 rpm | 105 bar (1500 psi) | 65 l/min (17.1 gpm)
0434 PH2 0628 N/AAuxiliary hydraulic supply pump
Characteristics : Volumetric pump | 1450 rpm | 105 bar (1500 psi) | 45.4 l/min (12 gpm)
0416 PQ1-1 0601 N/ALube oil main pump
Characteristics : Volumetric pump | 6.89 bar (100 psi) | 3000 l/min (792 gpm)
0416 PQ1-2 1006 N/ALube oil main pump