31
Mitsubishi Graphic Operation Terminal Simply the best GRAPHIC OPERATION TERMINAL GOT1000 Mitsubishi Electric Corporation Nagoya Works and Himeji Works are factories certified for ISO14001 (standards for environmental manage- ment systems) and ISO9001 (standards for quality assurance man- agement systems). http://MitsubishiElectric.co.jp/melfansweb/english/ It's not a mere display. It's a GOT.

Mitsubishi GOT1000

Embed Size (px)

DESCRIPTION

Mitsubishi GOT1000

Citation preview

Page 1: Mitsubishi GOT1000

Mitsubishi Graphic Operation TerminalS i m p l y t h e b e s t

GR

AP

HI

C

OP

ER

AT

IO

N

TE

RM

IN

AL

GO

T1

00

0

Mitsubishi Electric Corporation Nagoya Works and Himeji Works are factories certified for ISO14001 (standards for environmental manage-ment systems) and ISO9001 (standards for quality assurance man-agement systems).

http://MitsubishiElectric.co.jp/melfansweb/english/

It's not a mere display. It's a GOT.

Page 2: Mitsubishi GOT1000

It's what we do. Coming up with answers. Breaking new ground.And now it's here-the GOT1000-reflecting the next generation's vision.How far can a display evolve when functions are inspired by the voices of actual users, rather than a race for that "new look"?

To answer this question, Mitsubishi drew on its technology and experience cultivated at actual FA worksites, and the resulting GOT1000 sets the standard for the next generation.

In addition to raising the level of display basics such as response, display, and connectivity, the GOT1000 is packed with ideas and functions designed to improve productivity and workability.

In short, the GOT1000 is about usability, and creating new value.

The GOT1000 not only gives customers improved connectivity to PLCs and a host of other FA devices, it provides a powerful competitive edge in the global market as well.

T o w a r d a u n i q u e G O T b r a n d

Its beauty alone, its functionality alone, takes the GOT1000 beyond a mere "display". But what really sets it apart is the usability that was inspired by voices from actual worksites.

Concept

Lineup

Features

Connectable model list

Connection configuration

Bus connection

Specification

External dimensions

Function list for each model

Notes for use

List of products

2

4

819202226

28

32

38

48

50

52

54

56

For designersFor operatorsFor intial startup & adjustment operatorsFor maintenance personnelHandy GOT

I N D E X

S i m p l y t h e b e s t

The needs expressed by users will continue to be a central part of the GOT series evolution to the next-generation display. Mitsubishi Electric's aims are summed up by the slogan, "Simply the best!".

Page 3: Mitsubishi GOT1000

8.4''Type

Resolution: VGA 640 x 480Display colors: 16 colors

TFTGT1562-VNBA (AC type)GT1562-VNBD (DC type)

10.4''Type

Resolution: VGA 640 x 480Display colors: 256 colors

TFTGT1575-VNBA (AC type)GT1575-VNBD (DC type)

8.4''Type

Resolution: VGA 640 x 480Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle)GT1565-VTBA (AC type)GT1565-VTBD (DC type)

10.4''Type

Resolution: VGA 640 x 480Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle)GT1575-VTBA (AC type)GT1575-VTBD (DC type)

10.4''Type

Resolution: SVGA 800 x 600Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle)GT1575-STBA (AC type)GT1575-STBD (DC type)

12.1''Type

Resolution: SVGA 800 x 600Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle)GT1585-STBA (AC type)GT1585-STBD (DC type)Resolution: XGA 1024 x 768

Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle)GT1595-XTBA (AC type)

15''Type

USB interfaceStandard item & front-mounted

An innovative and highly perfected platform sets the GOT1000 Series in a class all by itself

Throughout our pursuit to deliver a solution that meets the needs of the industry, we developed an innovative platform based on performance, technology and design - the GOT1000 Series. This development concept is shared across the "Basic" (GT11 Series) and "Advanced" models (GT15 Series) to offer a wide range of flexible panel mount and pendant style solutions.

GOT1000 common features

Drawing, computing, communicationA triad of high-speed response

Beautiful and expressive screen

mDrawing...Equipped with a high-speed drawing chip (GT15 only)mComputing...Offers high-speed computing performancemCommunication...Bus connection (GT15 only) and RS-232 communication (max. 115.2kbps)

mUp to 20 times faster data transmission than previous modelsmFront-mounted USB interface allows fast data exchange

m65536 Full color (GT15)mMonochrome 16 gray scales (GT11)mGreatly increased memory capacity

Full-spec models accommodate a wide range of applications in stand-alone or network environmentsGT15

10.4''Type

Resolution: VGA 640 x 480Display colors: 16 colors

TFTGT1572-VNBA (AC type)GT1572-VNBD (DC type)

Features

Standard interface, standard memory size

Connection format*3

65536 colors 256 colors Human sensor

Multi channel Transparent System monitor

Intelligent unit monitor Q motion monitor Servo

amplifier monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Ethernetdownload

A/FX list editor

Network monitor

Memory 9MB

MELSECNET/10

Gateway

Ladder monitor

CNC monitor CNC monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

65536 colors 256 colors Human sensor

Multi channel Transparent System monitor

Intelligent unit monitor Q motion monitor Servo

amplifier monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Ethernetdownload

A/FX list editor

Network monitor

Memory 9MB

MELSECNET/10

Gateway

Ladder monitor

CNC monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

65536 colors 256 colors Ethernetdownload

Transparent System monitor A/FX list editor

Q motion monitor Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Gateway

Ladder monitor

Memory 9MB

MELSECNET/10

Multi channel

Intelligent unit monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

65536 colors 256 colors Ethernetdownload

Transparent System monitor A/FX list editor

Q motion monitor Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Gateway

Ladder monitor

Memory 9MB

MELSECNET/10

Multi channel

Intelligent unit monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

65536 colors 256 colors Ethernetdownload

Transparent System monitor A/FX list editor

Q motion monitor Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Gateway

Ladder monitor

Memory 9MB

MELSECNET/10

Multi channel

Intelligent unit monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

256 colors Ethernetdownload Gateway

System monitor A/FX list editor Ladder monitor

Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Multi channel

Intelligent unit monitor

Memory 5MB

MELSECNET/10

Transparent

Q motion monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

16 colors Ethernetdownload Gateway

System monitor A/FX list editor Ladder monitor

Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Multi channel

Intelligent unit monitor

Memory 5MB

MELSECNET/10

Transparent

Q motion monitor

CC-Link

*2

Features

Standard interface, standard memory size

Connection format*3

16 colors Ethernetdownload Gateway

System monitor A/FX list editor Ladder monitor

Servoamplifier monitor Network monitor

USB RS-232 CF card I/F

Bus Direct CPUconnection Computer link

Ethernet

Multi channel

Intelligent unit monitor

Memory 5MB

MELSECNET/10

Transparent

Q motion monitor

CC-Link

*2

*1: With high-resolution graphic board. *2: RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface. *3: Bus, MELSECNET/10, CC-Link, and Ethernet are compatible only with Mitsubishi PLCs.

Functions bearing this mark are available only on GT15 series models. All other functions are supported by both the GT11 and GT15 series.GT15

Page 4: Mitsubishi GOT1000

8 9

Featu

res and

recom

men

ded

po

ints

More design freedom through flexible connectivity

For designers

Collect and organize information from various FA devices to display on a single screen for quick reference

For designers

Barcord Reader

Inverter

Servo

Alarm

PLC

MELSEC

Recipe

Logging

Central storage of FA device informationMulti-channel function*

v Monitoring of up to 4 channels of FA devices (PLCs, servo amplifiers, inverters, temperature controllers, etc.).v Monitoring of all FA devices on a single screen on the GOT. Easily designed monitor screens.

Up to 4 simultaneous communication channels!

*: The number of channels and functions, which can be used with the multi-channel function, vary according to the connection configuration. For details, see the "Notes for use" on page 55.

Optional function board is required. GT15...GT15-QFNB(MM)

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71C24-R2QX41POWERQ61P-A1

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QX41POWERQ61P-A1

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

Brand "A" PLC

Brand "B" PLC Inverter

Temperature controller

Temperature controller

Temperature controller

Other brand PLCs MELSEC + Temperature controllers + Inverters MELSEC + MELSERVO

Stand-alone PLCs (FX, or other brand PLCs)

+ MELSECNET/10Example of communication unit combinations

Microcomputer, FX, other brand PLCs

MELSECNET/10

Servo amplifiers (pulse train type)

Serial communication unit

GOT rear face

Bus communication unit

m Examples of usage

Before... With multi-channel functions...

Required temperature controller programs = Increased PLC load.

Required computer link unit for temperature controller connection = Increased cost.

Requires no programs for temperature

controller = Reduces PLC load!

Requires no computer link unit for temperature controller connection

= Reduces cost!

Easy data exchange between PLCs

Stand-alone devices can be connected to the network

Up to 4 simultaneous communication channels Central management of alarms and parameters

Customers' needs

Ethernet

*1: No need to create screens to use the servo amplifier monitor function. For details on the servo amplifier monitor function, see the "Features and recommended points" on page 25. *2: Monitoring and writing of devices, which are equivalent to MELSEC-Q4A, are supported. CNC parameters can be specified by using the CNC monitor function. For details on the CNC monitor function, see the "Features and recommended points" on page 25.*3: GT15 requires an optional battery (GT15-BAT) in order to save clock data.

Brand "A" PLC

Brand "B" PLC

Brand "C" PLC

0123456789ABCDEF

POWER

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

Wide selection of connectable FA devices

The GOT1000 Series flexibly adapts to systems comprising various models and brands of FA devices

v The GOT1000 series has expanded the range of connectable devices, permitting connection to both Mitsubishi and other brand PLCs. (10 brands, including Omron, Yokogawa Electric, etc.)

v Connection with Mitsubishi servo amplifiers is possible to monitor parameters on flexibly designed screens.*1

v Also connectable to temperature controllers, and to Mitsubishi inverters and CNCs*2.

v The GT15 is equipped with a high-speed RS-232 interface as standard. Moreover, RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface.

v The GT11 is equipped with high-speed RS-232 and RS-422 interfaces (standard items) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.

v Internal clock function permits the use of alarm display and clock functions even when connected to a PLC which has no clock.*3

NEW

Other brand temperature controller

Mitsubishi PLC

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

POW

RUN

FX3UC-32MT-LTSTOP

ESC

OK

RUN

LRUN

BAT

ERR

LERR

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

Mitsubishi servo amplifier

NEW

[Mitsubishi PLC] FX3U; [Other brand PLCs] KEYENCE: KV-700/1000; Matsushita Electric Works: FP-E; SIEMENS: SIMATIC S7-200 Series

Newly compatible PLCs

For connectable FA devices, see the "Connectable model list" on page 28.For connection format specific features, see the "Connection configuration" section on page 32.

Mitsubishi CNC

Mitsubishi inverterPULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

Improved Microcomputer connectionFor wider GOT support of applications

v Offers wider communication protocol support (15 types).

• Mitsubishi A/QnA/Q-computer link unit (8 types)

• GOT-A900 series compatibility (2 types)

• GOT-F900 series compatibility (2 types)

• Digital Electronics (Proface) memory link format (3 types)

v Expanded D-device support, with the following devices now

supported: Bit devices: L, M, SM; Word devices: R, SD.

v The number of interruption points has been increased from 1 byte to a maximum of 4 bytes, enabling simpler control program design.

v The GOT1000 series has an internal clock function which can be used for alarm displays and clock functions.*

*: GT15 requires an optional battery (GT15-BAT) in order to save clock data.

Easy monitoring of temperature controller

data on GOT

GT11

Resolution: QVGA 320 x 240Display colors: 16 gray scales

Handy GOT/STNGT1155HS-QSBD (DC type)

Resolution: QVGA 320 x 240Display colors: 16 gray scales

STNGT1150-QLBD (DC type)

Resolution: QVGA 320 x 240Display colors: 256 colors

Handy GOT/STNGT1155HS-QSBD (DC type)

Resolution: QVGA 320 x 240Display colors: 256 colors

STNGT1155-QSBD (DC type)

5.7''Type

5.7''Type

5.7''Type

5.7''Type

Standard models offer a full array of basic functions for stand-alone use

There's a model for your needs.All 19 models in the GOT1000 lineup

offer the same user friendliness.

Features

Standard interface, standard memory size

Connection format

256 colors Vertical display Transparent

USB

Direct CPUconnection Computer link CC-Link

Connection formatDirect CPUconnection Computer link CC-Link

System monitor A/FX list editor

RS-422RS-232 CF card I/F Memory 3MB

Features

Standard interface, standard memory size

16 gray scales Vertical display Transparent

USB

System monitor A/FX list editor

Features

256 colors Transparent System monitor A/FX list editor

Features

16 gray scales Transparent System monitor A/FX list editor

RS-422RS-232 CF card I/F Memory 3MB

Standard interface, standard memory size

Connection format

USB

Direct CPUconnection Computer link CC-Link

Connection formatDirect CPUconnection Computer link CC-Link

RS-422RS-232 CF card I/F Memory 3MB

Standard interface, standard memory size

USB

*1 *1

RS-422RS-232 CF card I/F Memory 3MB

*1 *1

Functions with this mark are newly supported by the GT11 series, not only by the GT15 series.*1: Via G4 (AJ65BT-G4-S3) only.

coming soon coming soon

Page 5: Mitsubishi GOT1000

10 11

Featu

res and

recom

men

ded

po

ints

For greater freedom in creating beautiful screens that best suit your needs

For designers

Lead the way in information sharing between the office and worksite

Be alerted to worksite errors and collect worksite controller data from an office desk

Gateway function

*1: Requires MX Component Version3 or later. MX Component is a communication assistance tool that permits communications from a personal computer without having to identify the communication protocol and module. Data logging, collection, and saving is possible by programming at VBA. Applications that run in MX Component (MX Sheet, etc.) can also be used. *2: The devices required for Gateway function use at GOT1000 differ from those required at GOT-A900. For details, refer to the GOT1000 Series Gateway Function Manual.*3: Requires an SMTP (mail server). The mail transmission range depends on the SMTP specifications.*4: Be sure to use either GT15-QBUS or GT15-QBUS2.*5: Be sure to use either GT15-ABUS or GT15-ABUS2.*6: Communication between the Gateway function and a PLC is possible by using a single Ethernet communication unit.

v GOT (server) can be monitored from a personal computer (MX Component) to perform indirect reading/writing at PLC CPU devices being monitored by GOT.

v Even when monitoring other brand PLC CPUs, the server function can be used to perform reading/writing with the MX Component*1 alone.

v A GOT (server) can be monitored from another GOT (client) to perform indirect reading/writing at PLC CPU devices being monitored by GOT (server).

v The client function can be used to perform indirect reading/writing at PLC CPU brands other than the PLC CPU brand to which GOT (client) is connected.

v Communication is possible between GOT1000 and GOT-A900*2.

Server function & Client function

Mail transmission function

Collect data at a personal computer (server function)

Monitor other GOTs from a GOT (server function, client function)

[Devices required for gateway function use]

• Ethernet communication unit (GT15-J71E71-100)• Communication unit for connection to PLC• Optional function board (GT15-FNB or GT15-QFNB (MM))

Host personal computer

(client)

Brand "A" PLC Microcomputer board

MitsubishiPLC

GOT-A900(client)

Bus connection

RS-232 connectionRS-422 connection

Client function Server function

For designers

1

v Error information can be checked from a remote location away from the worksite.

v The alarm history display function can transmit alarm occurrence and recovery information by mail to a personal computer or cell phone.

Transmit mail from GOT to a personal computeror cell phone *3

3

2

2

2 1

GOT1000(Server)

GOT1000(client)

Data collected by MX Component

Worksite Office

Ethernet

Worksite

Worksite

Internet

Mitsubishi PLC

Mailserver

Bus connection

FTP serverfunction

3

4

GOT1000

Host personal computer (FTP client)Files checked by general-purpose software such as FTP client tools

Office

Mitsubishi PLC

GOT1000 (FTP server)

Bus connection

Mail transmissionfunction

[Gateway function compatible connection formats]

• Bus connection (MELSEC-Q)*4

• Bus connection (MELSEC-QnA/A)*5

• CPU direct connection• Computer link connection (MELSEC-Q/QnA/A)• CC-Link connection (via G4)• Ethernet connection *6

• CPU direct connection• Ethernet connection *6

Other brand PLC

Microcomputer board, personal computer, etc. (microcomputer connection)

Temperature controller connection

Connection Format (Between GOT and PLC)

FTP server function

Direct checking/editing of data in CF card (FTP server function)

4

v Files in a CF card in the GOT can be directly read and written from a personal computer (alarms, recipes, hard copies, etc.).

v No need to visit every factory to collect CF cards from every GOT when several GOTs exist or a GOT exists at a distant from a personal computer.

Mitsubishi PLC/Motion controller

Mitsubishi CNC (MELDAS C6/C64) connection

Vastly increased memory capacity

Draw without memory capacity worries

v GT15 is expandable to 57MB (optional) by using optional function board and CF card. GT15MM-MTBM: Standard 9MB memory (optional expansion up to 57MB) GT15MM-VNBM : Standard 5MB memory (optional expansion up to 53MB)

v Standard 3MB memory on the GT11.

v Design screens without worrying about memory capacity.

v BMP and JPEG* images can be used to create easy-to-understand screens.

*: JPEG format is supported only by the GT15.

GOT-F900

GT11

GOT-A900

GT15

Standard 512KB

Standard1MB Optional 8MB

Standard 9MB Optional 48MB

Standard 3MB

KB512

MB9

MB3

MB57

x6

x9NEW

An assortment of fonts allows more expression

Dramatically improved display is attractive and easy to view

v Supports Windows® compatible fonts*.

v When using a Windows® font, the font style (italics, underline, italics underline) can also be specified.

v Standard fonts, high-quality fonts, and TrueType fonts can be used in Gothic or Mincho styles*.

v Attractive characters in all sizes. TrueType fonts can be used.

v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages.

v Create elaborate, high-quality screens that are both attractive and easy to view.

Font Size StyleStandard font

High-quality font

TrueType font

Windows® font

6 x 8 dot

12 dot

16 dot

12 dot

16 dot

24 to 128 dot

8 to 128 dot

Gothic

Gothic

Gothic / Mincho

Gothic / Mincho

Gothic / Mincho

Gothic / Mincho1

*: Gothic and Mincho styles cannot be used together in the standard font.

*: All TrueType (other than vertical scripts) and OpenType fonts can be displayed.

Component layering (Layer function)More freedom in screen design

v Component (objects, figures) layering increases the freedom of design.

v Display layering is possible for components such as changing numerical values and graphs, line graphs, bar graphs, photo data, and pointers, etc.

v Offers effective use of a limited display area by allowing comments to be placed on lamps.

Error occurence

Front layer~Back layer Front layer~Back layer

Back layer

Front layer Front layer

Layer graphsComment & lampPhoto data & pointer

Back layer

Page 6: Mitsubishi GOT1000

12 13

Featu

res and

recom

men

ded

po

ints

For designers

Intuitive support tools for designing screens with graphics

For designers

Increase design efficacy with an impressive array of clever functions

Script FunctionMore flexible screen design with improved work efficiency and customization functions

v GOT's unique programs allow for changes of display depending on projects and screens.

v Controlling GOT display by using scripts of GOT can reduce the load on PLCs (PLC CPU, microcomputer, etc.) dramatically.

1. Project script / screen script

Kana-Kanji conversion function

Easy-to-read item management using Kanji

v This function enables the conversion of text entered in Kana (ASCII code) to Kanji. Users are allowed to enter operator names and product names in Kanji.

v After entering text with input keys (key code switches created by users), press Kanji conversion key (key code switch) to display the text in Kanji in Ascii input field.

v Within ASCII text, the cursor movement function enables users to move the cursor to any place in order to add characters.

v Drawing and display control functions can be specified for every object, allowing objects to easily be used in other projects.

v Scripts make screen display control highly flexible by changing properties (colors and display positions) and making the object design process flexible.

v Input support function of the GT Designer2 make it easy to specify functions and properties, thereby preventing spelling errors and reducing the time to look up control statements.

2. Object script*

m Example of how to use object script (draw straight line on graph display)

m GT Designer2 script editor screen (object script only)

*:Optional function board is required. GT15...GT15-FNB or GT15-QFNB( M)

Optional function board is required. GT15...GT15-FNB or GT15-QFNB( M)

Edit and insert selected items by using statement examples being displayed

Edit scripts directly

Select functions and properties from the item list

Check contents of a selected item

clear_object();

[w:TMP0003] = ([w:D0] + [w:D1] + [w:D2]) / 3;

[w:TMP0001] = 320 - (320*([w:TMP0003] /1000));

d_line(0, [w:TMP0001], 380,[w:TMP0001], 0, 3, 255);

[w:D0003] = [w:TMP0003];

// Delete the previous object (including a line).

// Calculate an average value.

// Calculate the position to display a line.

// Draw a line.

// Assign the average value.

Draw a line to show the average value according to monitor device values

[Comment registration]

[Example of comment group use]

Comment groups

Efficient input of extensive comment data by allotment

v Up to 255 comment groups can be created in addition to basic comments.

Multilingual support

Easy creation of a multilingual screen

Comment group 3: Line C commentComment group 2: Line B commentComment group 1: Line A comment

(1) Line-specific comment groups are created.

(2) Import

(3) Displayed comment group can be switched by device.

When "1" is selected When "2" is selected When "3" is selected

Switch-ing

If D10=1, Japanese displays

If D10=2, English displays

If D10=3, Korean displays

To switch between Japanese, English, and Korean screen

Example of comment group use

For D10 languageswitching device

(2) At a language switching device, specify the No. of the column to be displayed.(3) The displayed comment (language) changes.

(1) Create the Japanese, English, and Korean comments in their respective columns.

Line Aerror

Line B error

Line C error

Line A comment

Line B comment

Line C comment

QJ71C24-R2QJ61BT-11

PULL

POWERQ25HCPU

USB

QX42-S1

QJ61CL12

ON

TEST

MODE

B RATE

87654321

SW

POINTSI/O

PULL

MODERUNERR

USERBAT

BOOT

Q64P

QJ71C24-R2QJ61BT-11

PULL

POWERQ25HCPU

USB

QX42-S1

QJ61CL12

ON

TEST

MODE

B RATE

87654321

SW

POINTSI/O

PULL

MODERUNERR

USERBAT

BOOT

Q64P

QJ71C24-R2QJ61BT-11

PULL

POWERQ25HCPU

USB

QX42-S1

QJ61CL12

ON

TEST

MODE

B RATE

87654321

SW

POINTSI/O

PULL

MODERUNERR

USERBAT

BOOT

Q64P

Indi-vidually edited

v CSV / Unicode text format files can be imported. Different files can also be input to individual comment groups, allowing the comment input task to be distributed among several workers, greatly reducing the required input time.

v The drawing software allows easy column and line insertions and comment No. changes similar to those offered by Microsoft ® Excel.

v Line-specific comment groups can be created and displayed, and switching between those groups is possible, enabling easy integrated control of multiple lines in a single project's data.

v Language-specific comment groups can also be created, with switching between the different language screens.

v Different language comments can be created at each comment column No. to switch languages simply by specifying the desired column No. at a language switching device.

v Up to 10 columns* can be created for 1 comment No.

v Examples of use (for switching between Japanese, English, and Korean)(1) Create the Japanese, English, and Korean comments in their respective columns.(2) At a language switching device, specify the No. of the column to be displayed.(3) The displayed comment (language) changes. • Language-specific alarm display screens can also be easily created.

v Column comments can be created freely for applications, as well as for different languages.

Switch-ing

*: For details, refer to the "Comment Group" item.

Page 7: Mitsubishi GOT1000

14 15

Featu

res and

recom

men

ded

po

ints

For designers

For history management of production conditions and precise analysis of problem causes

For designers

Simplified maintenance through batch handling of recipe information

Logging function

Smooth operation from collection of various data to saving time series files

Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)

Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)

v Collecting data from temperature controllers and other units with GOT can reduce the load on PLC. · 250 device points per setting, 32 settings per project can be set.

v Collected data can be used for record and analytical purposes when being saved to a CF card. · Files can be saved in the GOT dedicated binary file, CSV and Unicode text file formats.

Historical trend graphEasy-to-read logging data in a graph display

v Data collected by the logging function can be displayed in a time series graph from a CF card as well as from a buffering area.

· Data collected by the logging function can be displayed in graph form. Past data can be displayed simply by pressing a scroll switch. · Displays a cursor, device value and time of the cursor position, allowing for enlargement or reduction of scales. · Up to 32 data can be displayed in a graph; up to 8 graphs can be added to a screen.

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

PLC

* Settings of the logging function are required in order to use historical trend graphs.

Temperature controller

Buffering area (GOT memory)

CF card

Collect device data from PLCs and temperature controllers into a buffering area

Save data in the buffering area to a CF card

Analyze data in the CF card (CSV or Unicode text file) on a personal computer

Display time and device value of a cursor position

Cursor display: Displays a cursor Cursor movement (return): Moves the cursor backward Zoom in: Enlarges the graph scale

Cursor Cursor Enlarge scale

Advanced recipeAutomated recipe operation without sequence programs

1. Extensive amount of setting files, device points, and record points.

3. Easy handling of recipe data at GOT

v A greatly expanded capacity permits up to 2048 files and 32767 device points.

v Up to 240 device records can be handled by a single advanced recipe setting file.

2. Flexible recipe data can now be created.v Flexible recipe data can be created by combining advanced recipe settings and records.

v Reading/writing is performed by specifying the recipe No. and record No., eliminating the need for a trigger device at each file. This reduces the number of required devices, and permits trigger device concentration.*1

v Up to 2048 blocks are possible, with 1 block comprising a sequential word device and random word device (1 point), and a bit device (1 point).

v Because devices also permit bit and word combinations and random device settings, there is no need to concentrate the sequential devices, thereby economizing on the number of device points.

v Advanced recipe files can be edited on a personal computer.*2

*1: The "recipe No. saving device", the "record No. saving device", and the "external control device" advanced recipe common settings can be specified at the advanced recipe device dialog box in GT Designer2 (these settings are required when using an advanced recipe). Recipe data reading and writing occurs in accordance with external device ON/OFF switching, and that data displays onscreen. (It is also possible to specify a trigger device for reading/writing of each advanced recipe setting.)*2: The advanced recipe file has a binary format. It must therefore be converted to a CSV file or Unicode text file by using GT Designer2 or the GOT's utility. After being converted, only the device values can be edited.

Select a recipe file

Select a record andexecute the recipe

This function allows material combination data and processing conditions data, etc. (device value) to be held at GOT, with only the required data being written/read to and from the PLC.

Advanced recipeinformation screen

Advanced reciperecord list screen

Advanced recipe setting 1: Curry

D1000

D1001

D1002

D1100

D1101

D1102

Beef

Pork

Chicken

Onion

Potato

Carrot

Record 1Beef Curry

Record 2Pork Curry

Record 3Chicken Curry

300

0

0

400

300

200

0

300

0

500

400

250

0

0

300

600

200

150

Advanced recipe setting

DeviceCommentDevice

Records (max. 240 records / setting)

Device blocks (max. 2048 blocks / setting)

Number of device points (max. 32767 points / setting)

An optional function board is required.GT15...GT15-FNB or GT15-QFNB (□M)

Usage example

GOT main unit

Max. 2048 settings / project

Recipe execution

v Recipes can be handled easily by GOT's utility function without having to create a recipe operation screen.

v The utility function permits the following operations: folder create/delete, advanced recipe file copy/delete/file name change, record write/read/consistency check.

v Advanced recipe files can be converted to CSV files or Unicode text files.

Page 8: Mitsubishi GOT1000

Wo

rkspace

Lib

raryed

itor

Tem

po

rary area

Dialo

g b

ox

Pro

perty sh

eet

16 17

Featu

res and

recom

men

ded

po

ints

Create designs the way you imagined them

For designers

v A setting content list can be displayed for the selected object or figure.

v Similar objects can be selected, and the color and font size can be set in one go.

v Multiple same-type objects and figures can be selected, and their color and character size, etc., can be batch-changed.

List display of object & figure setting content

v Language switching, security level change and on/off image switching of objects can be checked with the GT Designer2 on a personal computer.

v Consistency checks between the GOT's project data and the personal computer project data can be performed.

v This allows project data inconsistencies to be identified, thereby reducing unnecessary uploads and downloads.

v GT Designer → GT Designer2 compatibility*2

GT Designer2 is compatible with project data created by GT Designer.

v GOT-900 → GOT1000 compatibility*2

GOT1000 is compatible with project data created at GOT-900.

v Settings of the following functions can be imported/exported: logging, advanced recipe, advanced user alarm, recipe, alarm history and comment registration.

v Device data, range settings, device values, and comments, which have been created in a CSV/Unicode text file format, can easily be imported/exported to and from the GT Designer2.

v A component editing screen displays by double-clicking a registered component at the library workspace.

v Editing of registered components is quick and easy.

Dedicated component editing screen

v Placing objects in a temporary area facilitates smoother screen creation and screen layout change operations.

Smoother screen creation

Screen previewEasy confirmation of screen display

Improved import/export function

Higher efficiency by using familiar software

v The drawing software can display window screens (key window, overlapping window, superimposed window) just as they will appear at GOT, allowing them to be previewed.

v The key pad can

be displayed just as it will appear at GOT, allowing its position, size, and appearance etc., to be checked.

Forward compatibility

Reliably compatible with existing GOT projects reuse work friendly to customer existing resources compatible

Project data consistencycheck function

Better project data maintenance efficiency

*1: Compared to Mitsubishi Electric's GT Designer.*2: Forward compatibility does not extend to certain data and functions. Moreover, GOT1000 screen data cannot be used at GOT-900.

It's easy to see the entire project so the screen to be edited can be selected right away.

The device, color, and figure of components can be batch-changed in screen or category units, even when located on multiple screens.

Frequently used components can be registered as "favorites", permitting quick access to an object or figure.

An intuitive tree display,with easy copying and deletion

Project workspace

Category workspace

Library workspace

*: "Category" refers to objects or figures that have been grouped according to purpose.

v A setting content screen displays by double-clicking the object or figure.

v Figure changes are immediately reflected onscreen.

This allows work to be performed while checking the onscreen results, thereby simplifying the process and reducing setting errors.

Object & figure setting screen

*: This is possible at the "Property Sheet" as well.

Version2

Reduction in screen drawing time by half*1

Windows®stan-dard operability

and menuconfiguration

Data compati-bility with

GT Designer

Reduction inscreen drawing

time by half

Display all settings in a list

Start wizard

Easy to set system settings, screen switching settings, multiple communication settings

v Interactive wizard helps users create a new project by configuring necessary settings for the GOT1000.

Wizard function

User-friendly setting procedure puts even beginners at ease

Edit a spreadsheet with software such as Microsoft Excel

import /export

Read created data into the GT Designer2 (Import)

Save contents of settings of the GT Designer2 to CSV/Unicode text files (Export)

Window previewDisplay of actual GOT screen

Example of how to switch languages

Select column No.1 Select column No.2

Select a column No. of the comment group to be displayed

Column No. of comment group

Con-sistencycheck

Page 9: Mitsubishi GOT1000

vThe GT15 lineup offers an array of display colors depending on usages. GT15MM-MTBM : Standard model offers a 256-colors display. 65536 colors are

available when the multi-color display board is installed. JPEG and BMP images can be used at the troubleshooting screen, etc., for vivid and easy-to-understand displays.

GT15MM-VNBM : Standard model offers either a 256-colors or 16-colors display.

vThe GT11 is available with either a 256-colors display or a monochrome (black & white) display. The 256-colors type features a long-life backlight with a lifespan of 75,000 hours or more. The monochrome (black & white) display offers a 16 gray scales for improved expression.

vA high intensity, with a wide-view angle and vivid colors offers sharp and attractive displays.

vA high transmissivity protection sheet* is available to protect the screen and prevent reflection, resulting in a clear, easy-to-view screen.

18 19

Featu

res and

recom

men

ded

po

ints

Efficient debugging

For designers

256 colors65536 colors

STN monochrome 16 gray scales STN color, 256 colors

GT15

State-of-the-art operation environment

Drawing, computing, communication; a triad of high-speed response functions

Dramatically improved GOT total response

65536-colors full color / monochrome 16 gray scales

Sharp display that's easy to view

The GOT1000 Series offers faster response in drawing, computing, and communication, reducing monitoring and operation stress.

v High-speed drawing of figures and characters was realized through the development of drawing chip especially for the GOT1000 Series.v Sharp and quick drawing of complex, layered component screens, and detailed photographic data.

v High-speed RS-232 communication (max. 115.2kbps).v GT15 high-speed communication is possible by bus connection.v High-speed communication is possible for connections with both Mitsubishi and other brand PLCs.

v Ultra high performance processing power to satisfy the most complex and demanding of applications.

Easy switching between different languages

Accommodates production site globalization

v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages.

v Correctly display Simplified Chinese and Traditional Chinese characters *1 (GT15 only)

v Allows the creation of elaborate, high-quality screens that are both attractive and easy to view.

vOne-touch switching between different-language screens*2

accommodates different languages spoken by production site operators.

For operators

GT11

Response comparison with GOT-900 series

GOT- 900

GOT1000

For connectable PLC models, see the "Connectable model list" from page 28. For connection format specific features, see the "Connection configuration" section from page 32.

NEW

NEW

Equipped with a high-speed drawing chip (GT15 only). High-speed drawing

High-speed communication

GT11: Equipped with 64-bit RISC processor GT15: Equipped with 64-bit super-scalar RISC processor

High-speed computing

Bus connection

CPU direct connection

Computer link connection

MELSECNET/10 connection(Transient)

CC-Link (ID) connection(Transient)

Ethernet connection

Other brand direct connection[Yokogawa Electric. FA-M3]

FX direct connection[MELSEC FX3UC]

0.2 0.4 0.6 0.8 1.0

*1: Optional function board is required. GT15...GT15-FNB or GT15-QFNB(MM)*2: For function details, see the "Multilingual support " section on page 12.

Version2

GX Simulator GX Developer

Click with mouse

Programming softwareVirtual PLC

Virtual GOT1. Debugging is possible from a single personal computer, without actual GOT and PLC operation required.*1

3. Device monitor function permits monitoring of a wide array of devicesv Monitoring is possible for displayed devices. (GOT internal devices can also be monitored.)

vIn addition to displayed devices, monitoring is also possible for devices with common settings, as well as for overlapping windows 1 & 2, and superimposed windows 1 & 2.

v Because devices can be registered freely, it is possible to register multiple devices which are to be monitored.

2. Debugging is possible by connection with a PLC, without actual GOT operation requiredDebugging can be performed using a direct CPU connection between a personal computer (GT Simulator2) and a PLC, without actual GOT unit.Connection is possible to Mitsubishi and Omron PLCs*2.

4. Powerful support of customer specifications compatibility checks and document creationvWhile observing the operation image, the customer's screen specifications can be arranged without actual unit operation.

v Display screen snapshots can be saved to the personal computer's hard disk as BMP/JPEG files that are extremely useful when creating specifications and operation manuals.

*1: Requires GX Simulator (ladder logic test tool). *2: For connectable PLC model information, see the "Connectable model list" on page 28.[Unsupported functions] For lists of functions which cannot be simulated (utility function, optional function, etc.), refer to the GT Simulator 2 Version 2 Operation Manual.

GX Developer

Lo

ad p

rog

ram

Lo

ad d

rawin

g

data

Drawing software

Programming softwareCommunication / monitoring

Virtual GOT

GX SimulatorVirtual PLC

Sequence program

Omron PLC

RS-232 / RS422 connection

Mitsubishi PLC

RS-232 connection

Screen imageat personal computer

GT Simulator 2

Click with mouse

v A GT Simulator2 screen debugging function permits screen editing in GT Designer2 with the results immediately verifiable in GT

Simulater2, thereby greatly reducing debugging man-hours.v The input to a touch switch is simulated by clicking on the touch switch on GT Simulator2 with the mouse. The result of input to the touch switch can be confirmed by a display change on GT Simulator2, the device monitor screen on GX Simulator, or the ladder monitor of GX Developer.v GT Simulator2 can be used in combination with a sequence program created in GX Developer to recreate the screen motion, allowing debugging to be performed in an intuitive manner.v System alarm and script error information can be checked in GT Simulator2, even if no system alarm settings have been specified in GT Designer2.

RUN

Approx. times faster response4

*: The protection sheet is an optional item.

One-touch

language switching

[Using MELSEC-Q series]

GT15 response performance comparison

Randomly monitor 250 numerical displays (word devices) (1.0 for computer link connection is a comparison standard)

Connectable PLCs

Mitsubishi PLC (Q/QnA/A/FX series)

Mitsubishi PLC (MELDS C6/C64)

Omron Corp. PLC*2

PLC ⇔ Personal Computer Connection

RS-232/RS-422

RS-232

Page 10: Mitsubishi GOT1000

20 21

Featu

res and

recom

men

ded

po

ints

For minimizing procedure man-hoursand setup

For initial startup & adjustment operators

*: Requires an Ethernet communication unit (GT15-J71E71-100) installed in a GOT main unit where basic functions have also been installed.Downloading/uploading other than the Boot OS and OS installation is possible. (Resource data can only be uploaded.)

RS-232interface

CF cardinterface

RS-232interface

RS-422interface

GT11

CF cardinterface

HandyGOT

RS-232interface

CF card interface

GT15

Up to times faster12Mbps 20

Equipped with front USB interfaceEasy cable connection without opening the cabinet

FA transparent functionEdit sequence programs without opening the cabinet

*: Compliance cannot be guaranteed in all customer environments. Moreover, the IP67f rating does not apply when a USB cable is connected.

IP67fStandard item (with IP67f-rated port cover installed)

With USB cable

GT15 GT11

v A front USB interface allows cables to be connected without having to open the cabinet. Work efficiency is improved by eliminating the time-consuming process of opening and closing the cabinet door at GOT data transmissions.

v The USB interface is a standard item for all models. Data transmission can be up to 20 times faster than the previous RS-232 format, greatly reducing the time required for startup and adjustment.

v Equipped with an IP67f-rated port cover as standard. When secured by screws, the cover complies with the IP67f* standard.

v The IP67f-rated port cover is easily opened/closed by coin screws.

v Sequence program debugging, startup, and adjustment can be performed via GOT's front USB interface.*1 There is no need to open the cabinet and change cable connections. (Operation is also possible via the RS-232 interface.)*2

v When GOT is connected to a Mitsubishi PLC by bus connection*3 or direct CPU connection, program reading, writing, and monitoring can be performed via GOT.

Comparison of project data downloading times

GOT-900(RS-232)

GOT1000(USB)

Data transmission time

38.4kbps

Short Long

*1: Requires GX Developer Version 8.22Y or later.*2: When the GOT internal RS-232 interface is used to connect to the PLC, GOT can only be connected to a personal computer by the USB interface.*3: When multiple GOT units are connected by a bus connection, the FA transparent function can be used at each of the GOT units.

MELSECNET/10, etc.

USB/RS-232

*: For software access ranges when using the FA transparent function, refer to manual for the software being used.

GX Developer

Y100

Y70

M0

M500

Y100

Y70

M0

M500

Bus connection or direct CPU connection

High-speed downloading/uploading* via Ethernet

Project data can be maintained from a remote location

v Project data from a personal computer at a remote site can be downloaded and uploaded to a GOT terminal by way of Ethernet.

Ethernet

DownloadUpload

DownloadUpload

Mitsubishi PLC

Worksite

OfficeGT Designer 2

Up to times faster100Mbps 20

Comparison of project data downloading times

GOT-900(RS-232)

GOT1000(Ethernet)

Data transmission time

38.4kbps

Short Long

Standard-item RS-232 interface

For GOT data transmissions & a variety of external connections

v Both the GT15 and GT11 have RS-232 interfaces located in convenient positions (bottom, and side face, respectively) for cable connection.

v Used for FA device connection, data transmission, bar-code reader connection, etc.

Up to times faster4

Comparison of project data downloading times

GOT-900(RS-232)

GOT1000(RS-232)

Data transmission time

38.4kbps

115.2kbps

Short Long

Standard-item CF card interfaceEasy GOT data transmissions & setup

v All models are equipped with a CF card interface as standard.

v Permits rapid GOT data transmissions even when GOT is not connected by cable to a personal computer.

v When using multiple GOT units, a single CF card enables a quick GOT setup procedure simply by copying the data to each GOT unit.

coming soon

Page 11: Mitsubishi GOT1000

22 23

Featu

res and

recom

men

ded

po

ints

Rapid diagnostics and identification to minimize machine downtime

Advanced alarmFrom error detection to recovery

The GOT1000 Series offers quick error detection and cause identification, enabling a speedy system recovery.

(upper step)Alarms by line

Alarms by unit

Alarm content

Step1

(middle step)Step2

(general step)Step3

Troubleshooting

(details screen)Step4

Advanced alarm features

4-step alarm notification

Alarm observationfor up to

32767 devices

Alarm observationsubjects

Display of active and recovery-completed alarms

Display of activealarms only

Popup display

Alarm display settings History file saving

Alarm Transport G alarm display

Minor alarm display

Transport G major alarms display

GroupGroup

Level

Combination level

& group

Level

Max. of 255settings

Alarm observationsettings

M0M1M2M3M4M5M6M7M8M9

Transport GTransport GTransport GTransport GTransport GProcess GProcess GProcess GProcess GProcess G

Mid-levelMid-levelMid-levelMid-level

MajorMajorMinorMinorMinorMinor

Unit "B" observationsettings

1. A wider monitoring range protects even large-scale systems.2. Rapid detection and corrective action for a wide array of alarms.3. Easy-to-understand error displays for the operator.4. Improved system alarms.5. Support in identifying alarm causes.

v Alarm observation is possible for up to 32767 devices, with a maximum of 255 alarm observation setting groups.v 3 types of alarm displays can be specified for a single alarm observation setting.v Up to 32767 alarms can be saved in the alarm history.v Batch display of large amounts of alarm information in large-scale systems, and unit-specific classification for easy management.

1. A wider monitoring range protects even large-scale systems.

v The use of colors and popups produce easily recognizable alarm displays.vEnsures that alarms are not overlooked and that the alarm content is understood, resulting in a speedy system recovery.

3. Easy-to-understand display

v The PLC/GOT/Network monitoring subject can be specified in advance, with only those specified alarms being displayed.vIf desired, only the active alarms are displayed. An alarm history display and history file saving are also possible.

4. Improved system alarms

v Alarm occurrence conditions can be displayed in time-series graph form.v Alarm occurrence counts can be displayed in bar-graph form.v A graphical statistics display facilitates efficient analysis of error causes.

5. Support in identifying alarm causes (utility function)

2. Rapid detection and corrective action for a wide array of alarms.

v Alarm occurrence conditions can be divided into 4 steps, and conveyed to the operator in an easy-to-understand, step-by-step format.

Group-specific & level-specific displays

v Alarms can be classified by group and level, with only the specified alarms being displayed.

v This makes it easy to identify the locations and types of alarms, even when many alarms have occurred, and permits the higher priority alarms to be handled first, resulting in a speedy system recovery.

Where isthe error?

What kindof error?

When willrecovery occur?

v The 4 steps shown above can be freely defined to suit the application in question, with switching between the step displays performed by the step switching device or by touch-screen operation.

When multiple alarms occur, the above format permits the operator to quickly organize and identify the alarm conditions (where, what kind of alarm), resulting in effective troubleshooting.

1. Alarms by line (upper step)2. Alarms by unit (middle step)3. Alarm content (general step)4. Troubleshooting (details step)

For

exa

mpl

e...

1. By groupAlarms are divided into groups (transport unit group, processing unit group, etc.), with alarms displaying only for the specified groups.

2. By levelAlarms are divided into levels (major, mid-level, minor), with only the specified level alarms displaying.

3. Combination group & levelOnly the specified group and level alarms display.

For maintenance personnel

Details display

Alarm popup display

A popup display format ensures that user alarms and system alarms are not missed. The background color can be specified.

Display subject switching

Display switching is possible to display only active alarms or to display all content.

Comment display color

Comment display colors can be specified for each alarm status (occurred, restored, and checked) and for each level and group, etc.

Sorting

A sorting function permits the display order of the date & time, level, group, alarm status, occurrence count, and downtime items to be changed.

Cursor display color

The cursor display color can be specified. Alarm displays are harder to miss, and the freedom of screen design has been increased.

Floating alarm display

Permits the entire text of long comments which cannot be contained in the display area to be read.

JPEG images can be displayed in the details display area.

Device "A" error

Out of material

Materialreplenishment

Line "A" stops

Unit "A" observationsettings

Alarmoccur-rence

Page 12: Mitsubishi GOT1000

24 25

Featu

res and

recom

men

ded

po

ints

Convenient method for minor program changes onsite

List editor for A / List editor for FX

v MELSEC-A series, FX series PLC sequence programs can be edited in a list format (instruction word).v Permits minor program changes onsite, even without peripheral devices.v The GT15 permits sequence program editing while viewing the ladder (combined with the ladder monitor function).

Sequence program monitoring & troubleshooting

Ladder monitor function

v Monitoring of Mitsubishi PLC sequence program and various searches of devices can be performed. • Monitoring in ladder format. • Device values and Timer (T)/counter (C) setting values can be changed. • A coil (or contact) can be touched to search for contacts (or coils) of the same device.*1

v When a problem occurs, an alarm history can be displayed, and a back-tracking ladder search can be performed to find the contact which triggered the alarm.

For maintenance personnel

Requires optional function board.

NEW

GT15...GT15-FNB or GT15-QFNB (MM)GT11...GT11-50FNB

At-a-glance monitoring of MELSECNET network status

Network monitor function

v Network status of the MELSECNET/H, MELSECNET/10 and MELSECNET II can be monitored on a dedicated screen.

v Communication line, information from the host and other stations can be monitored to check the communication status.

*1: MELSEC-Q/QnA series only.

*2: Supported only if the Q series motion controller CPU has SV13/SV22 OS version. Moreover, available functions of Q series motion monitor vary according to the CPU type.

Easy adjustment of Q series motion controller

Q series motion monitor function

v Monitoring of servo amplifiers and parameter settings of Q motion controllers can be performed.*2

v Monitoring and parameter settings can be performed for up to 3 units of Q172(N) /Q173(N) on the same base unit.

Easy-to-understand display of buffer memory values and I/O information

Intelligent unit monitor function

v Buffering memory values of intelligent function units and ON/

OFF status of I/O units can be monitored and changed.

v When a QCPU (Q mode) is in use, CPU operating status and existing errors can be monitored by PLC diagnosis.

*3: Available monitoring functions vary according to the servo amplifier type.

*4: Supported by GT15 series XGA and SVGA models.

Easy startup and adjustment of servo amplifier

Servo amplifier monitor function

v In a system which outputs pulse strings, GOT can be connected to a servo amplifier in a serial connection to perform the following operations: setting up, monitoring, alarm display, diagnosis, parameter setting, and test operations.*3

v When multiple servo amplifiers are connected, monitor screens can be easily switched on a GOT by specifying station numbers.

Space and cost saving because no dedicated display device is required

CNC monitor function

v When a MELDAS C6/64 is connected, position display monitor, alarm diagnosis monitor, and tool offset parameters can be set on GOT as well as on a display device dedicated to MELDAS.

v Up to 64 CNC units can be monitored in an Ethernet connection. Only a control station can be monitored in a MELSECNET/10 connection.

*4

List editor for FX

List editor for A

Convenient maintenance tools

Color-coded front face LED & maintenance schedule notification function

Backlight maintenance required.

mMaintenance schedule notification function (GT15 only)

v The backlight lifespan can be monitored by an automatic "power ON time" count function, combined with a 2-stage maintenance schedule notification function.

v Monitored subjects • Backlight, display area (power ON time) • Touch-keys (key pressing count) • Internal flash memory (writings count)

v Facilitates scheduled maintenance, thereby preventing system malfunctions.

1. Color-coded front face LED

2. Maintenance schedule notification function (GT15 only)

v The color of the LED on the front of the GOT unit indicates whether the backlight is OFF or has expired.

2nd notification

Backlight maintenance required soon.

1st notification

Requires optional function board.GT15...GT15-FNB or GT15-QFNB (MM)

Battery required.GT15...GT15-BAT

[POWER LED: Color-coded message]

Green ON

Orange ON

Orange/green blinking

OFF

When normal power is being supplied

When in screen-save mode

When backlight life has expired

When power is not being supplied

System alarm

occurs

System alarm

occurs

Sequence device monitoring / changes

System monitor function

v Mitsubishi PLC CPU devices can be monitored and changed. • Monitoring can be performed by selecting the device to be monitored, or by specifying the initial device. • The timer (T) / counter (C) current values and setting values can be changed.v A special function unit's buffer memory (BM) can be monitored and changed.v The display format (decimal / hexadecimal) and the device comment display status (ON/OFF) can be switched.

For easy monitoring and other operations ofMitsubishi FA devices

Optional function board is required for functions shown on this page.GT15...GT15-FNB or GT15-QFNB (MM). GT15-QFNB (MM) is required in order to use Q/QnA ladder monitor function.

Page 13: Mitsubishi GOT1000

26 27

Featu

res and

recom

men

ded

po

ints

Unlimited mobility wherever you are within a facility

Handy GOT

Flexible usage and connectivity of Handy terminals

vRestricts access to certain operations (manual/auto switching, mode selection, setup change, etc.) to authorized operators.

Portable and wearable Handy terminals can also be mounted on a wall or a machine

mKey type selector switch

vGT1155HS-QSBD has 256 colors; GT1150HS-QLBD has 16 gray scales.

mDisplay equivalent of GT11

vImproved safety by using 2 break contacts connected in series, either of which can execute a stop command when being switched off.

v3 position switch is adopted. (OFF-ON-OFF) Connected to an external device as a dead-man switch, grip switch can be used for the immediate execution of a command to stop a machine.

mEmergency stop switch of 2 break contacts

mGrip switch

vWired directly to an external device input as push-button switches, 6 operation switches can be used to operate and stop a machine. Furthermore, the operation switch names can be changed as desired.

vThe control panel is equipped with an LED lamp (green) for verifying operation of these switches.

m6 operation switches

vThe CF card interface permits fast GOT data transmission.

mCF card interface

vThe USB interface permits fast data transmission between GT Designer2 and GOT.

mUSB interface (standard item)

vThe RS-232 interface is provided for GOT data transmission when the USB interface is not used.

vEmergency stop switch guard (GT11H-50ESCOV)

mRS-232 interface

vEither the RS-232 or RS-422 format can be selected for communication with connected devices.

mRS-232 / RS-422 communication

mOptional devices

RS-232/RS-422 RS-232/RS-422

RS-232/RS-422

FA devices

To power supply and operation switches

To power supply and operation switches

FA devices

Model name Connectionconfiguration Connected FA device Connection port External connection cable FA device interconnection relay cable

A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand PLC, microcomputer, servo, CNC, temperature controller

A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand FA device, microcomputer, servo, CNC

External connection cable GT11H-CMMM-37P

External connection cable GT11H-CMMM

PLC interconnection relay cable

FX0S, FX0N, FX1NC, FX2NC,

FX3U, FX3UC,

CPU programming port

FX1S, FX1NCPU programming port or FX1N-422-BD

FX2NCPU programming port or FX2N-422-BD

A, QnA, A motion controller CPU programming port

CPU programming port

Connectable FA devices (see "Connectable model list" on page 28)

Connectable FA devices (see "Connectable model list" on page 28)

GT1155HS-QSBD

GT1150HS-QLBD

GT11H-CMMM-37P MMM: 30(3m)/60(6m)/100(10m)

GT11H-C15R4-8P(1.5m)

GT11H-C15R4-25P(1.5m)

GT11H-CMMM

MMM: 30(3m)/60(6m)/100(10m)

GT11H-C30-37P

Q GT11H-C15R2-6P(1.5m)

GT11H-C30-37P

GT11H-CMMM

MMM: 30(3m)/60(6m)/100(10m)

When the connection distance between Handy GOT and PLC exceeds the cable length shown in the table, the user must fabricate an FA device interconnection relay cable. For further connection cable details, refer to the Handy GOT Operation Manual.

Termination of GT11H-CMMM is required in accordance with the devices to be connected.

Termination of GT11H-CMMM is required in accordance with the devices to be connected.

To be fabricated by user.

To be fabricated by user.

1 2

1

1 2

Handy GOT

For RS-232 connection

For RS-422 connection

The connection distance between Handy GOT and PLC must not exceed 11.5m.

The connection distance between Handy GOT and PLC must not exceed 6m.

RS-422

RS-232

GT1155HS-QSBD/GT1150HS-QLBD Handy GOT FA device interconnection cables

vProtective sheet (GT11H-50PSC)

vCF cardvOptional function board (GT11-50FNB)vReplacement battery (GT11-50BAT)vExternal connection cablevPersonal computer connection cable (GT01-C30R2-6P (RS-232 cable)) (GT09-C20USB-5P (USB cable))

LED lamp for grip switch

Display area

Removable logo mark

Replaceable name label

Key type selector switchUSB interface

Emergency stop switch

6 operation switches

Lightweight, thin and easy-to-handle cable

CF card interfaceHook to attach neck strap

Hand strap

Grip switch

One-touch connection of optional cable

GT1155HS-QSBD : 256 colorsGT1150HS-QLBD : 16 gray scalesEquipped with touch switches equivalent of GT11.

coming soon

Page 14: Mitsubishi GOT1000

C o n n e c t a b l e m o d e l l i s tThe GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.

Q00JCPU Q00CPUQ01CPUQ02CPUQ02HCPUQ06HCPUQ12HCPUQ25HCPUQ12PHCPU Q25PHCPUQ12PRHCPUQ25PRHCPUQJ72LP25-25QJ72LP25GQJ72BR15Q02CPU-AQ02HCPU-AQ06HCPU-AQ2ACPUQ2ACPU-S1Q3ACPUQ4ACPUQ4ARCPUQ2ASCPUQ2ASCPU-S1Q2ASHCPUQ2ASHCPU-S1A2UCPUA2UCPU-S1A3UCPUA4UCPUA2ACPUA2ACPUP21A2ACPUR21A2ACPU-S1A2ACPUP21-S1A2ACPUR21-S1A3ACPUA3ACPUP21A3ACPUR21A1NCPU A1NCPUP21A1NCPUR21A2NCPUA2NCPUP21A2NCPUR21A2NCPU-S1A2NCPUP21-S1A2NCPUR21-S1A3NCPUA3NCPUP21A3NCPUR21

MELSEC-Q series (Q mode)

MELSECNET/H remote I/O stationsMELSEC-Q series (A mode)

MELSEC-QnA series (QnACPU type)

MELSEC-QnA series (QnASCPU type)

MELSEC-A series (AnCPU type)

Series Model name

Busconnection

*1*2

CPU direct

connection

MELSECNET/10

*1*3

CC-Link(ID)*1*4

CC-Link (via G4)

*4

Ethernet

A2USCPUA2USCPU-S1A2USHCPU-S1A1SCPUA1SCPUC24-R2A1SHCPUA2SCPUA2SCPU-S1A2SHCPUA2SHCPU-S1A1SJCPUA1SJCPU-S3A1SJHCPUA0J2HCPUA0J2HCPUP21A0J2HCPUR21A0J2HCPU-DC24A2CCPUA2CCPUP21A2CCPUR21A2CCPUC24A2CCPUC24-PRFA2CJCPU-S3A1FXCPUQ172CPUQ173CPUQ172CPUNQ173CPUNQ172HCPUQ173HCPUA273UCPUA273UHCPUA273UHCPU-S3A373UCPUA373UCPU-S3A171SCPUA171SCPU-S3A171SCPU-S3NA171SHCPUA171SHCPUNA172SHCPUA172SHCPUNA173UHCPUA173UHCPU-S1FX0SFX0NFX1SFX1NFX1NCFX2NFX2NCFX3UFX3UC

MELSEC-A series (AnSCPU type)*13

MELSEC-A series *13

Motion controller CPU (Q series)

Motion controller CPU (A series) (large type)

Motion controller CPU (A series) (small type)*13

MELSEC-FX series

SeriesConnection configuration Connection configuration

*1: Supported only by the GT15.*2: When connecting multiple GOTs, note that the following GOT models cannot be used together:

GOT1000 series, GOT-A900 series, GOT800 series, and A77GOT.*3: When MELSEC/H is used in NET10 Mode, the GOT terminal cannot be connected directly to a

Remote I/O station.*4: CC-Link (ID): Connected as CC-Link (intelligent device station). CC-Link (via G4): Connected to a

CC-Link system via AJ65BT-G4-S3.*5: When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges

within QnACPU specifications are supported.The following devices cannot be monitored:· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.· File register (R)· Local devices

*6: Use CPU function version "B" or later in a multiple CPU system.*7: When using a bus extension connector box, it must be installed at an extension base. (It cannot

be installed at the main base.)*8: Use function version "B" or later for the CPU and MELSECNET/H network unit.*9: Does not support automatic system switch. (If there is only 1 GOT, plug the GOT cable into the

CPU of the control system to be monitored. If there are 2 GOTs, plug each of them into the respective CPUs of the "A" and "B" systems to be monitored.)

*10: Does not support automatic system switch. (Use the script to switch systems.)*11: With redundant system, the standby system automatically takes over the control if control

system goes down.*12: In Q4ARCPU redundant systems, GOT must be bus-connected to the last stage's redundant

system extension base A68RB version "B" or later.*13: Computer link unit software version "U" or later must be used for the A2SCPU, A2SHCPU,

A1SHCPU, A1SJHCPU, A0J2HCPU, A171SHCPU, and A172SHCPU computer link connections.The A0J2-C214-S1, dedicated computer link unit for A0J2HCPU, cannot be used.

*14: Only the following software version or later can be used to write data to the AnNCPU (S1), A2SCPU, A0J2HCPU, and A2CCPU. Earlier versions cannot be used.· AnNCPU (S1) : A "with link" status requires version "L" or later, and a "without link" status requires version "H" or later.· A2SCPU : Version "H" or later· A0J2HCPU (with link/without link) : Version "E" or later· A0J2HCPU-DC24 : Version "B" or later· A2CCPU : Version "H" or later

*15: Cannot connect to bus if an extension base is connected.*16: Use of the SV13, SV22, or V43 requires a motion controller with the following OS version

installed.

SW6RN-SV13Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists)SW6RN-SV22Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists)SW6RN-SV43Q□: 00B or later

*17: Only a USB interface is available on Q172HCPU and Q173HCPU units. The Q172HCPU and Q173HCPU can be accessed using a multi-CPU system QCPU RS-232.

*18: Use a unit with the following serial No.Q172CPU Serial No. K******* or laterQ173CPU Serial No. J******* or later

*19: Use a unit with the following serial No.Q172CPU Serial No. N******* or laterQ173CPU Serial No. M******* or later

*20: If an extension base is to be used, use the A168B.

MELSEC-Q series (Q mode)MELSECNET/H remote I/O stations

MELSEC-Q series (A mode)

MELSEC-QnA series

MELSEC-A seriesA series Motion controller CPU

QJ71C24QJ71C24-R2QJ71C24NQJ71C24N-R2QJ71C24N-R4QJ71CMOA1SJ71UC24-R2A1SJ71UC24-R4AJ71QC24AJ71QC24-R2AJ71QC24-R4AJ71QC24NAJ71QC24N-R2AJ71QC24N-R4A1SJ71QC24A1SJ71QC24-R2A1SJ71QC24NA1SJ71QC24N-R2AJ71UC24AJ71UC24A1SJ71UC24-R2A1SJ71UC24-R4A1SJ71C24-R2A1SJ71C24-R4A1SCPUC24-R2A2CCPUC24

RS-232RS-232RS-232RS-232RS-422/485Module connectorRS-232RS-422/485RS-232RS-232RS-422RS-232RS-232RS-422RS-232RS-232RS-232RS-232RS-232RS-232RS-232RS-422/485RS-232RS-422/485RS-232RS-232

RS-422/485RS-232RS-422/485RS-232RS-422/485RS-232!

!

RS-422/485RS-232RS-422/485RS-422/485RS-232RS-422/485RS-422/485RS-232RS-422/485RS-232RS-422/485RS-422/485!

!

!

!

!

RS-422/485

vFor computer link connection

CPU seriesModel CH1 CH2

Computer link modules/serial communication modules *1

mModules that can be connected with Mitsubishi PLC

*2

*2

*3

*4

*4

*4

*4

*4

*4

*4

*4

*4

*4

*4 *6

*4 *5

*5

*5

*5 *6

*5 *6

*5

*4

*2

*2

*2

*2

MELSEC-Q series (Q mode)*1

MELSEC-QnA series

MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU

QJ71LP21QJ71LP21-25QJ71LP21S-25AJ71QLP21AJ71QLP21SA1SJ71QLP21A1SJ71QLP21SAJ71LP21A1SJ71LP21

QJ71BR11

AJ71QBR11A1SJ71QBR11

AJ71BR11A1SJ71BR11

vFor MELSECNET/10 connection

CPU seriesOptical loop Coaxial bus

MELSECNET/H(NET/10 mode), MELSECNET/10 modules

MELSEC-Q series (Q mode)

MELSEC-QnA series

MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU

QJ71E71-100QJ71E71-B5QJ71E71-B2QJ71E71AJ71QE71N3-TAJ71QE71N-B5AJ71QE71N-B2AJ71QE71N-TAJ71QE71N-B5TAJ71QE71AJ71QE71-B5AJ71E71N3-TAJ71E71N-B5AJ71E71N-B2AJ71E71N-TAJ71E71N-B5TAJ71E71-S3

A1SJ71QE71N3-TA1SJ71QE71N-B5A1SJ71QE71N-B2A1SJ71QE71N-TA1SJ71QE71N-B5TA1SJ71QE71-B5A1SJ71QE71-B2A1SJ71E71N3-TA1SJ71E71N-B5A1SJ71E71N-B2A1SJ71E71N-TA1SJ71E71N-B5TA1SJ71E71-B5-S3A1SJ71E71-B2-S3

vFor Ethernet connectionCPU series Ethernet module *1

MELSEC-Q series (Q mode)

MELSEC-QnA series

MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU

QJ61BT11QJ61BT11NAJ61QBT11A1SJ61QBT11AJ61BT11A1SJ61BT11

vFor CC-Link (ID) connection *1

CPU series CC-Link unit

MELSEC-Q series (Q mode)QJ61BT11QJ61BT11N

AJ65BT-G4-S3

vFor CC- Link (via G4) connection *1

CPU series CC-Link unit Peripheral deviceconnection unit

*1:RS-485 communication is not possible; therefore, A0J2-C214-S1 is not available.When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges within QnACPU specifications are supported.The following devices cannot be monitored:· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.

· File register (R)· Local devices

*2: With function version "A", CH1 or CH2 can be connected. With function version "B" or later, both CH1 and CH2 can be connected.*3: Only CH2 can be connected.*4: Either CH1 or CH2 can be connected.*5:: When connecting to A1SHCPU, A2SCPU(S1), A2SHCPU(S1),

A1SJHCPU, A0J2HCPU, A171SHCPU(N), A172SHCPU(N), use computer link module software version U or later version.

*6: Computer link module/serial communication module operate within the range of devices available on AnACPU. (R device cannot be used.)

*1: The GT11 can monitor only the master station.

*1: This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.

*2: GOT can perform transient communication only with CC-Link units running function version "B" and software version "J" or later.

*1: Use function version "B" or later for the CPU and MELSECNET/H network unit.

*7

*8

*9 *8*10 *10*15

*18

*20

*18

*17

*14

*19 *19 *19 *19 *19

*16

*16

*16

*16

*14

*11 *11

*6

*6

*6

*6

*6

*6

*1

*12

*14

*1: When using an A-series Ethernet (E71 modules) with QCPU/QnACPU, only the device ranges within AnACPU specifications are supported except for the following devices.· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).(At the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.)· File register (R)· Local devices

Mitsubishi PLCs/motion controllers

28 29

Co

nn

ectable m

od

el list

[PLC/motion controller]In addition to a bus connection, GT15 can also be connected to a MELSECNET/10 or Ethernet network.The GT11 is equipped with RS-232 and RS-422 interfaces (as standard) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.

Computer-link con-

nection *5

Model name

Busconnection

*1*2

CPU direct

connection

MELSECNET/10

*1*3

CC-Link(ID)*1*4

CC-Link (via G4)

*4

Ethernet*1

Computer-link con-

nection *5

*14

j

j

j

j

j

2

2

2

2

j

j

j

j

2

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

j

2

j

j

j

2

j

j

2

j

j

j

j

j

2

j

j

j

j

j

2

2

2

2

j

2

j

j

j

j

j

j

2

2

2

j

j

j

j

j

j

2

j

2

2

j

j

j

j

2

j

j

2

2

2

2

j

j

j

j

2

j

j

2

2

2

2

j

j

j

j

2

2

2

2

2

22

j

j

2

2

2

j

2

2

2

2

22

j

j

j

2

j

2

Page 15: Mitsubishi GOT1000

*1: RS-422 or RS-232 is selectable.*2: Connection to DH485 network possible via adaptor (1770-KF3).*3: Connection to DH485 requires a "Series-C" or later CPU. ("Series-B" and earlier models do not support

the DH485 protocol.)*4: A one-to-one connection requires a "Series-D" or later CPU. ("Series-C" and earlier models do not

support the DF1 half-duplex format.)

V

V

V

V

V

VV

@

@

@

V

VV

V

@

@

@

@

@

V

@

V

@

V

@

V

@

@

@@

@

V

V

V

V

�������������������������

V

V

@

V

@

V

@

@

@

@

@

@

@

@

@

V

@

V

@

V

V

V

@

@

@

@

@

@

Model nameManufacturerComputer link connection

RS-422 RS-232 RS-422 RS-232CPU direct connection

OMRON

KEYENCE

SHARP

TOSHIBA

Hitachi

Industrial

Equipment

Systems

Micro PLC

Small-sized

PLC

Large-sized

PLC

PROSEC

T series

V series

Large-sized

H series

H200 to 252

series

H series

board type

EH-150 series

FA500

FA-M3

SLC 500 series *2

MicroLogix 1000 series

(Digital CPU) *2

MicroLogix 1000 series

(Analogue CPU) *2*3*4

MicroLogix 1200 series *2

MicroLogix 1500 series *2

CPM1A

CPM1

CPM2A

CPM2C

C200H

C200HS

C200HX

C200HG

C200HE

CQM1

CQM1H

CS1H

CS1G

CS1D

CJ1H

CJ1G

CJ1M

C1000H

C2000H

CV500

CV1000

CV2000

CVM1

KV-700

KV-1000

JW-21CU

JW-31CUH

JW-50CUH

JW-22CU

JW-32CUH

JW-33CUH

JW-70CUH

JW-100CUH

JW-100CU

Z-512J

T2(PU224)

T2E

T2N

T3

T3H

model 3000(S3)

model 2000(S2)

H-302(CPU2-03H)

H-702(CPU2-07H)

H-1002(CPU2-10H)

H-2002(CPU2-20H)

H-4010(CPU3-40H)

H-300(CPU-03Ha)

H-700(CPU-07Ha)

H-2000(CPU-20Ha)

H-200(CPU-02H, CPE-02H)

H-250(CPU21-02H)

H-252(CPU22-02H)

H-252B(CPU22-02HB)

H-252C(CPU22-02HC)

H-252C(CPE22-02HC)

H-20DR

H-28DR

H-40DR

H-64DR

H-20DT

H-28DT

H-40DT

H-64DT

HL-40DR

HL-64DR

EH-CPU104

EH-CPU208

EH-CPU308

EH-CPU316

@

@

@

@

@

V

@

@

@

@

@

@

V

V

V

V

@

@

V

@

V

@

V

V

V

V

@

V

@

@

V

V

@

V

@

@

@

@

@

@

V

@

V

@

V

@

@

@

Model nameManufacturerComputer link connection

RS-422 RS-232 RS-422 RS-232CPU direct connection

Matsushita Electric Works

Yaskawa Electric

Yokogawa

Electric

Allen-Bradley

(Rockwell)

SIEMENS

FP0-C16CT

FP0-C32CT

FP1-C24C

FP1-C40C

FP2

FP2SH

FP3

FP5

FP10(S)

FP10SH

FP-M(C20TC)

FP-M(C32TC)

FP-·

GL120

GL130

GL60S

GL60H

GL70H

CP-9200SH

CP-9300MS

MP-920/930

MP-940

PROGIC-8

CP-9200(H)

FA500

F3SP05

F3SP08

F3SP10

F3SP20

F3SP30

F3FP36

F3SP21

F3SP25

F3SP35

F3SP28

F3SP38

F3SP53

F3SP58

F3SP59

SLC500-20

SLC500-30

SLC500-40

SLC5/01

SLC5/02

SLC5/03

SLC5/04

SLC5/05

1761-L10BWA

1761-L10BWB

1761-L16AWA

1761-L16BWA

1761-L16BWB

1761-L16BBB

1761-L32AWA

1761-L32BWA

1761-L32BWB

1761-L32BBB

1761-L32AAA

1761-L20AWA-5A

1761-L20BWA-5A

1761-L20BWB-5A

1762-L24BWA

1764-LSP

SIMATIC S7-200 series

SIMATIC S7-300 series

SIMATIC S7-400 series

*1

*1

*1

*1

*1

*1

*1

*1

Co

nn

ectable m

od

el list

C o n n e c t a b l e m o d e l l i s t

31

Other brand PLCs/motion controllers

[PLC/motion controller]Achieve maximum 115.2kbps high-speed communication with other brand PLCs via RS-232 communication. Having an RS-422 converter unit or serial communication unit on the GT15, can be performed RS-422 communication.The GT11 model is embedded with both an RS-422 and RS-422 interface as standard.

30

OMRONUpper-level link unit, communication unit, communication board

C200H-LK202-V1C500H-LK201-V1CQM1-SCB41CJ1W-SCU41CS1W-SCB41C200HW-COM03C200HW-COM06

C200H-LK201-V1C500H-LK201-V1CS1W-SCU21CS1W-SCB21CS1W-SCB41CJ1W-SCU41C200HW-COM02C200HW-COM05C200HW-COM06CQM1-CIF01CQM1-CIF02CQM1-SCB41CPM1-CIF01CPM2C-CN111CPM2C-CIF01-V1

RS-422Manufacturer RS-232

mModules that can be connected to other brand computer link module

mModules that can be connected to Mitsubishi CNC

Manufacturer Model name RS-422 RS-232

OMRON

YAMATAKE

RCK

Thermac NEO

In-Panel NEO

SDC

DMCH-PCP-J H-PCP-A,H-PCP-B

E5ANE5ENE5CNE5GNE5ZNSDC20/21SDC30/31SDC40A/40B/40GSDC15SDC25/26SDC35/36DMC10

MR-J2S-□AMR-J2S-□CPMR-J2M-P8AMR-J2M-□DUMR-J3-□A

@

@

@

@

@

@

@

@

@

@

@

@

V

V

RS-485V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (4-wire type)V (4-wire type)V (4-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type) @

V

V

V

V

V

V

V

V

V

V

V

V

V

V

RS-422Manufacturer RS-232

KEYENCE KV-L20RKV-L20

KV-L20RKV-L20

Hitachi Industrial Equipment SystemsIntelligent serial port module

Matsushita Electric WorksComputer communication unit

COMM-HCOMM-2H

JAMSC-120NOM27100JAMSC-IF612

COMM-HCOMM-2H

AFP2462AFP3462AFP5462

Yaskawa Electric Memo bus module

JAMSC-IF60JAMSC-IF61CP-217IF

LC02-0NF3LC11-2N

Yokogawa ElectricPersonal computer link module

LC01-0NLC02-0NF3LC01-1NF3LC11-1NF3LC11-1FF3LC12-1F

SHARP Link unit

JW-21CMJW-10CMZW-10CM

[Servo amplifier]

[Temperature controller]

Servo amplifiers Set parameters and display alarms when connected to Mitsubishi servo amplifiers.

CNC MELDAS C6/C64 monitoring and parameter settings can be performed.

Inverter Set parameters and display alarms when connected to Mitsubishi inverters.

Temperature controller Log data, set parameters, and display alarms when connected to temperature controllers.

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*2

*2

*2

*2

*2

*2

*2

*2

Manufacturer Model name RS-422 RS-232

MITSUBISHIFREQROL-S500/E500/A500/F500 FREQROL-A700/F700

V

V

@

@

Manufacturer Model name RS-422 RS-232

MITSUBISHI

MELSERVO-J2-Super series

MELSERVO-J2M series

MELSERVO-J3 series

V

V

V

V

V

V

V

V

V

V

[CNC]

[Inverter]

*1:Supported only by the GT15.*2:RS-232/RS-485 conversion adaptor is required.

SeriesConnection configuration

Modelname

Busconnection

CPUdirect

connection

Computer-link con-nection

MELSECNET/10

CC-Link(ID)

CC-Link(via G4)

Ethernet*1*1*2 *1*3

MELDASC6/C64

FCA C6FCA C64

@ V@VV@V*4 *4 *4*5

*1: Supported only by the GT15.*2: When MELSECNET/H is used in NET/10 Mode, the GOT terminal cannot be connected directly to a Remote

I/O station.*3: CC-Link (ID): Connected as CC-Link (intelligent device station).

This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.

*4: Use NC system software version D0 or later.*5: Use NC system software version E0 or later.

MELDAS C6/C64 FCU6-EX879 FCU6-EX878

vFor MELSECNET/10 connection

SeriesOptical loop Coaxial bus

MELSECNET/H (NET/10 mode), MELSECNET/10 module

MELDAS C6/C64 FCU6-HR865

vFor CC-Link (ID) connectionSeries CC-Link unit

MELDAS C6/C64 FCU6-EX875

vFor Ethernet connectionSeries Ethernet unit

The GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.

F

Page 16: Mitsubishi GOT1000

C o n n e c t i o n c o n f i g u r a t i o n

RS-232�cable

RS-422�cable

GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m

vFX series (FX1S, FX1N, FX2N)FX series (FX1S, FX1N, FX2N)(Function extension board (FX□N-232-BD) for RS-232)

(Function adaptor (FX2NC-232-ADP) for RS-232) *2

(Function adaptor (FX0N-232-ADP) for RS-232) *2

FX series (FX1S, FX1N, FX2N)(RS-422 CPU port)(Function extension board (FX□N-422-BD) for RS-422)

RS-232�cable

GT01-C□R2-9S30: 3m

GT01-C□R2-25P30: 3m

RS-232

RS-422

GT15

RS-232

RS-422

RS-422�cable

GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m

vFX series(FX1NC,FX2NC)FX series (FX1NC, FX2NC)(Function adaptor (FX2NC-232-ADP) for RS-232)

(Function adaptor (FX0N-232-ADP) for RS-232)

FX series(FX1NC,FX2NC)(RS-422 CPU port)

when using the function extension board or the function adaptor specified on the right.

when using function adaptor specified on the right

( when using RS-422 CPU port )2 units

Maximum number of GOTs connected

Maximum connection distance

1 unit

15m

when using the function extension board (FX□N-422-BD)

2 units

Maximum number of GOTs connected

Maximum connection distance

1 unit

30m

( when using RS-232 function adaptor )2 units

Maximum number of GOTs connected

Maximum connection distance

1 unit

30m

( when using RS-422 CPU port )2 units

Maximum number of GOTs connected

Maximum connection distance

1 unit

15m

GT01-C□R2-9S30: 3m

GT01-C□R2-25P30: 3m

RS-422

RS-422�cable

GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m

FX series (FX3UC, FX3CU)(RS-422 CPU port)(Function extension board (FX3U-422-BD) for RS-422)( when using RS-232 CPU port )3 units

Maximum number of GOTs connected

Maximum connection distance

2 units

30m

when using the CPU port and the function extension board specified on the right.

*2:A Function extension board is required.

RS-422

RS-422�cable

GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m

vFX series(FX0S,FX0N)FX series(FX0S,FX0N)(RS-422 CPU port)

Maximum number of GOTs connected

Maximum connection distance

1 unit

30m

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

FX0N-232ADPPOWER

RD

SD

FX2NC-232ADP

FX2NC-16MT

FX0N-24MR

32 33

Co

nn

ection

con

figu

ration

Maximum connection distance

Maximum number of GOTs connected

Maximum connection distance

vQnA / ACPU / A series Motion controller CPU

QCPU Q series Motion Controller CPU MELSECNET/H remote I/O station (CPU port: RS-232)

QCPU Q series Motion Controller CPUMELSECNET/H remote I/O station (CPU port: RS-232)

GT01-C□R2-6P30:3m

RS-232 cable

1 unit

3m

FA-CNV□CBL*12402: 0.2m2405: 0.5m

RS-422�cable

RS-232

RS-422

GT01-C□R4-25P30: 3m100: 10m

200: 20m300: 30m

GT01-C□R4-25P30: 3m100: 10m200: 20m300: 30m

1 unit

30.5m

RS-232/422conversion cable

QnA/ACPU/A series Motion Controller CPU (CPU port: RS-422)

RS-422�cable

GT15

GT15

RS-422

GT15

Maximum number of GOTs connected

Maximum connection distance

1 unit

30m

*1:This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.

0123456789ABCDEF

0123456789ABCDEF

To achieve optimum performance, select one of the various connection configurations as well as the units to be connected, the distance, and the maximum number of GOT terminals. For connection configuration when using multi-channel function, refer to the "Notes for use" on page 55.

Embeddedin GOT

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT15-RS2T4-9P

Serial communication

unit

RS-422 converter

Embeddedin GOT

GT15-RS2T4-9P

RS-422converter

GT15-RS4-9S

or

Serial communication

unitGT15-RS4-9S

or

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT15

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT11

GT11

GT11

GT11

GT11

GT11

GT11

GT11

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

Fabricated by user when length exceeds 3m.

Fabricated by user when length exceeds 3m.

( )AnN,AnS(H),A1SJ(H)

QCPU (Q mode) Q series Motion Controller CPU

GT15-QC□BGT15-QC□BS

Bus connection unit

Bus connection unit

Bus connection unit

5 units

37m

Connectionconfiguration Connection cable Connected toMaximum number of GOTs connected

Maximum connection distance

Maximum number of GOTs connected

Maximum connection distance

Maximum number of GOTs connected

Maximum connection distance

Communication interface installed on GOT side

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

vQCPU (Q mode) / Q series Motion controller CPU

vQnA/ACPU

vQCPU / Q series Motion controller CPU

QnA/ACPUGT15-C□NBGT15-AC□BGT15-A1SC□BGT15-A1SC□NBGT15-C□EXSS-1*1

GT15-C□BSGT15-J2C□B

GT15-C□NBGT15-AC□BGT15-A370C□B-S1GT15-A370C□BGT15-A1SC□BGT15-C□EXSS-1*1

GT15-C□BS

when connected with QnACPU type/AnCPU type

when connected with A273UCPU/A273UHCPU(-S3)/A373UCPU(-S3): with extension base

when connected with A273UCPU/A273UHCPU(-S3)/A373UCPU(-S3): without extension base

when connected with A171SHCPUN/A172SHCPUN/A173UHCPU(-S1): with extension base

when connected with A171SHCPUN/A172SHCPUN/A173UHCPU(-S1): without extension base

3 units

36.6mwhen connected with QnASCPU type/AnSCPU type36m

2 unitsA0J2HCPU1 unit

( )A171SHCPUNA172SHCPUN

2 units

vA series Motion controller CPUA series Motion Controller CPU

3 units

36.6m

32.5m

33m

30m

MELSEC-Q/QnA/A/FX series can be connected via CPU direct connection at the lowest cost.CPU direct connection

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

vQCPU (Q mode) / QnACPU / Q series Motion controller CPU

Connects multiple GOTs easily via serial communication (connecting one or two GOTs with one computer link unit).Computer link connection

Refer to Bus connection on page 38 and following for details.

GT15

GT15

GT15

*1: See the external dimensions information (page 51 and following) for the GT15-C□EXSS-1 cable shape.*2: Use of the Ethernet download and Gateway function requires the GT15-QBus (2). Note that the GT15-75QBus (2) L cannot be used.*3: Use of the Ethernet download and Gateway function requires the GT15-ABus (2). Note that the GT15-75ABus (2) L cannot be used.

GT15-75QBUSL*2

GT15-75QBUS2L*2GT15-QBUS*2

GT15-QBUS2*2

0123456789ABCDEF

Touch switches achieves as quick response as pushbuttons.Bus connection

Mitsubishi PLC

GT15-75ABUSL*3

GT15-75ABUS2L*3GT15-ABUS*3

GT15-ABUS2*3

GT15-75ABUSL*3

GT15-75ABUS2L*3GT15-ABUS*3

GT15-ABUS2*3

RS-232

GT15

RS-232�cable

vFX series (FX3U, FX3UC)FX series (FX3U, FX3UC)(Function extension board (FX3U-232-BD) for RS-232)(Function adaptor (FX3U-232-ADP) for RS-232)*2

GT01-C□R2-9S30: 3m when using the function extension board or

the function adaptor specified on the right.( when using RS-422 CPU port )3 units

Maximum number of GOTs connected

Maximum connection distance

2 units

15m

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

Fabricated by user when length exceeds 3m.

To be fabricated by user. QCPU (Q mode) / QnASCPU type Q series Motion Controller MELSECNET/H remote I/O station

QnACPU type

1 unit

15m

Maximum connection distance

1 unit

15m

Maximum number of GOTs connected

Maximum connection distance

RS-232�cable

RS-232�cable

D-sub 9 pins (female) D-sub 9 pins (male)

To be fabricated by user.

D-sub 9 pins (female) D-sub 25 pins (male)

RS-232

( when QJ71C24N-R2 is used )2 units

AJ71UC24-S2

AJ71UC24-S2

0123456789ABCDEF

GT15

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT15

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT11

GT11

GT11

GT11

ERROR

RUN

BATT

POWER

0 31 2

0 31 2IN

OUT

4 75 6

4 75 6FX3U-16MFX3U

R

ERROR

RUN

BATT

POWER

0 31 2

0 31 2IN

OUT

4 75 6

4 75 6FX3U-16MFX3U

R

Serial communication unit

Serial communication unit

Bus connection

cable

Bus connection

cable

Bus connection

cable

( )

Page 17: Mitsubishi GOT1000

C o n n e c t i o n c o n f i g u r a t i o n

RS-422�cable

CC-Link dedicated cable

For details, refer to the "Connectable model list" on page 30.

26 units

Maximum connection distance

CC-Link dedicated cable

CC-Link communication

unit

GT15-75J61BT13-Z (For intelligent device station)

AJ61QBT11

05

9

4

8

3

7

2

6

108

F

7

E

6

D

5

C

4

B

3

A

2

9

105

9

4

8

3

7

2

6

105

9

4

8

3

7

2

6

1

CC-Link unit

QCPUQnA/ACPU (Master/local station)A series Motion Controller CPU

0123456789ABCDEF

(When transient transmitting suggested 5 or less GOTs)

Maximum connection distanceGT15-J71E71-100

100m

AJ61QBT11

05

9

4

8

3

7

2

6

108

F

7

E

6

D

5

C

4

B

3

A

2

9

105

9

4

8

3

7

2

6

105

9

4

8

3

7

2

6

1

Ethernet unit

QCPUQnA/ACPUA series Motion Controller CPU

0123456789ABCDEF

1 unit

Maximum connection distance AJ61QBT11

05

9

4

8

3

7

2

6

108

F

7

E

6

D

5

C

4

B

3

A

2

9

105

9

4

8

3

7

2

6

105

9

4

8

3

7

2

6

1

CC-Link unit

QCPU (Q mode)Q series Motion controller CPU (RS-232 CPU port)

0123456789ABCDEF

AJ65BT-G4-S3

10BASE-T cable100BASE-TX cable

GT01-C□R4-25P30 : 3m100: 10m200: 20m300: 30m

Ethernetcable

Ethernet communication

unit

Maximum segment length

Connection cable to other brand PLC*1

RS-422�cable

D-sub 9 pins (male)

Depending on the PLC CPU specifications to which the GOT is connected.

Compatible with the following other brand PLC CPUs· OMRON· KEYENCE· SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · Matsushita Electric Works · YASKAWA Electric · YOKOGAWA Electric · Allen-Bradley (Rockwell Automation) · SIEMENS

Compatible with the following other brand PLC CPUs· OMRON· KEYENCE· SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · YASKAWA Electric · YOKOGAWA Electric

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

D-sub 9 pins (female)

Connection cable to other brand PLC*1

1 unit

Maximum connection distance

Depending on the PLC CPU specifications to which the GOT is connected.

Maximum number of GOTs connected

1 unit

Maximum connection distance

RS-232cable

RS-422

RS-232

0123456789ABCDEF

POWER

0123456789ABCDEF

POWER

*1: GT11 can only monitor the master station.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed. For details, refer to the user's manual for the CC-Link master/local unit being used.

*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed.

34 35

Co

nn

ection

con

figu

ration

D-sub 9 pins (male)

QCPU (Q mode) / QnASCPU type Q series Motion Controller CPUMELSECNET/H remote I/O station

QnACPU type

vQCPU (A mode) / ACPU / A series Motion controller CPUQCPU (A mode) / ACPU / A series Motion Controller CPU

15m

1 unit

Maximum number of GOTs connected

Maximum connection distance

To be fabricated by user.RS-232�cableD-sub 9 pins (female)

D-sub 9 pins (male)

Maximum number of GOTs connected

Maximum connection distance

To be fabricated by user.

500m

1 unit

Maximum number of GOTs connected

Maximum connection distance

RS-422�cable

D-sub 9 pins (male)

To be fabricated by user.RS-422�cable

1 unit

1200m 500m

Maximum number of GOTs connected

Maximum connection distance

1 unit

1200m 500mD-sub 9 pins (male)

RS-422�cable

GT01-C□R4-25P30: 3m100: 10m

Fabricated by user when length exceeds 30m.

RS-422

RS-422

RS-232

GT15

GT15

( when AJ71UC24 is used )

( when QJ71C24N-R4 is used )2 units

D-sub 9 pins (female)

D-sub 25 pins (male)

*1: MELSECNET/H is also used in NET/10 mode.*2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELSECNET/H and MELSECNET/10 Reference Manuals.

*1: This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.

AJ71UC24-S2

0123456789ABCDEF

AJ71UC24-S2

AJ71UC24-S2

Fiber-optic cable 63 units

Maximum connection distance

MELSECNET/10communication unit

Fiber-opticcable

Coaxial cableCoaxialcable

GT15-75J71LP23-Z(Optical loop)GT15-75J71BR13-Z(Coaxial bus)

Maximum number of GOTs connected

31 units

Maximum connection distance

AJ61QBT11

05

9

4

8

3

7

2

6

108

F

7

E

6

D

5

C

4

B

3

A

2

9

105

9

4

8

3

7

2

6

105

9

4

8

3

7

2

6

1

Network unit

QCPU QnA/ACPU (Control station/normal station)/ A series Motion Controller CPU

0123456789ABCDEF

Opticalloop

Coaxialbus

*2With QSI optical cable, maximum distance between stations is

*2

1km

500m

200: 20m300: 30m

GT15

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

GT15

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

GT15

Embeddedin GOT

Embeddedin GOT

orSerial

communicationunit

GT15-RS2-9P

GT15

Embeddedin GOT

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

orConnection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)MELSECNET/10 Connection (PC-to-PC Network)

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Supporting other brand PLC CPUConnection to other brand PLC

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Connects microcomputer board or personal computer to the GOTs.Microcomputer connection

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Connects CC-Link system as intelligent device station.*1CC-Link (ID) connection

Connectionconfiguration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Connectable to CC-Link by way of AJ65BT-G4-S3. *1CC-Link (via G4) connection

Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.Ethernet connection

To be fabricated by user.RS-422�cable

D-sub 9 pins (male)

Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.

Microcomputer board, personal computer, PLC, etc.

D-sub 9 pins (female)

To be fabricated by user. 1 unit

Maximum connection distance

Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.

Maximum number of GOTs connected

1 unit

Maximum connection distance

RS-232�cable

RS-422

GT15GT15-RS2T4-9P

RS-232

GT15

PULL

USB

Q25HCPU QX10 QJ71BR11RUN

T.PASSSD

ERR

MNGD.LINKRDERR

RUNT.PASS

SDERR

MNGD.LINKRDERR

QX41

0123456789ABCDEF

MODE

RUN

ERR

USER

BAT

BOOT

PULL

QJ71BR11QX41POWERQ61P-A1

Serial communication

unit

RS-422converter

Embeddedin GOT

Embeddedin GOT

Embeddedin GOT

GT15-RS4-9S

or

orSerial

communicationunit

GT15-RS2-9P

Connectionconfiguration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Other brand PLC

Microcomputer

GT11

GT11

GT11

GT11

GT11

GT11

GT11

GT11

GT11

Serial communication unit

Serial communication unit

Computer link unit

( )when A1SJ71UC24-R4 or A1SJ71C24-R4 is used.

( )

With 5C-2V coaxial cable, maximum distance between stations is 500m( )

(For CC-Link dedicated cable at 156kbps: )

*2

1200m

Peripheral device connection unit for GPP function

( )1230m1200m

30m

: CC-Link dedicated cable 156Kbps

: RS-422 cable

+

In the following cases:

*2

128 units(Suggested less than 16 GOTs)

Page 18: Mitsubishi GOT1000

Maximum connection distance

Maximum number of GOTs connected

Maximum connection distance

MELDAS C6/C64 *1

MELDAS C6/C64 *1

To be fabricated by user.RS-232cable

1 unit

3m

RS-422�cable

RS-232

RS-422

GT01-C□R4-25P30: 3m100: 10m200: 20m300: 30m

1 unit

30.5m

GT15

GT15

Embedded in GOT

Embedded in GOT

Embedded in GOT

orSerial

communicationunit

GT15-RS2-9P

GT15-RS2T4-9P

Serial communication

unit

RS-422converter

GT15-RS4-9S

or

Maximum connection distance

Maximum number of GOTs connected

1 unit

Maximum connection distance

RS-485

GT15

RS-485

GT15

Embedded in GOT

GT15-RS4-9S

Serial communication

unit

Serial communication

unit

GT15-RS4-TE

or

GT15-RS4-TE

Serial communication

unit

Temperature controller· YAMATAKE

C o n n e c t i o n c o n f i g u r a t i o n

RS-422�cable

Maximum connection distance

Maximum number of GOTs connected

1 unit

Maximum connection distance

RS-232cable

RS-422

GT15

RS-232

GT15

D-sub 9 pins (male)

Terminal block

Terminal block

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

D-sub 9 pins (female)

D-sub 9 pins (male)

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

RS-232 1 RS-422 2

Connected PLCs RS-232 cable 1 RS-422 cable 2

30m15m

When the first device is connected via RS-232 connection

FX2N-32MR

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

0 1 2 3 4 5 6 7

10 11 12 13 14 15 16 17IN

POWERRUNBATT.VPROG.ECPU.E

RS-232 2RS-422 1

15m30m

When the first device is connected via RS-422 connection

QCPUQJ71C24, QJ71C24N, QJ71C24-R2, QJ71C24N-R4FX1S+FX1N-232BD / FX1N+FX1N-232BD or FX1S+FX2NC-232ADP / FX1N+FX2NC-232ADP*2FX2N+FX2N-232BD or FX2N+FX2NC-232ADP*2FX1NC+FX2NC-232ADP / FX2NC+FX2NC-232ADPFX3U+FX3U-232BD or FX3U+FX3U-232ADP*2FX3UC+FX3U-232BD or FX3UC+FX3U-232ADP*2

GT01-C30R2-6P (3m)Fabricated by user.

GT01-C30R2-9S (3m)Fabricated by user.

Connected PLCs RS-422 cable 1 RS-232 cable 2

A/QnACPU

QJ71C24, QJ71C24N, QJ71C24N-R4FX1S/FX1NCPU or FX1S+FX1N-422BD/FX1N+FX1N-422BDFX2NCPU or FX2N+FX2N-422BDFX1NC / FX2NCCPUFX3UCPU or FX3U+FX3U-422BDFX3UCCPU or FX3UC+FX3U-422BD

GT01-C30R4-25P (3m)GT01-C100R4-25P (10m)GT01-C200R4-25P (20m)GT01-C300R4-25P (30m)Fabricated by user.GT01-C10R4-8P (1m)GT01-C30R4-8P (3m)GT01-C100R4-8P (10m)GT01-C200R4-8P (20m)GT01-C300R4-8P (30m)

GT01-C30R2-9S (3m)

Servo amplifierMELSERVO-J2-Super seriesMELSERVO-J2M seriesMELSERVO-J3 series

Servo amplifierMELSERVO-J2-Super seriesMELSERVO-J2M seriesMELSERVO-J3 series

30m

15m

500m

500m

L1 L2 L3

U V W

OPEN

36 37

Co

nn

ection

con

figu

ration

RS-422�cable

InverterFREQROL500 seriesFREQROL700 series

*1

Maximum connection distanceRS-422

GT15-RS2T4-9PGT15

Serial communication

unit

RS-422converter

GT15-RS2T4-9P

RS-422converter

Embedded in GOT

Embedded in GOT

Embedded in GOT

GT15-RS4-9S

or

Serial communication

unit

GT15-RS4-9S

or

Serial communication

unit

GT15-RS2-9P

or

RS-422�cable

1 unit

Maximum number of GOTs connected

1 unit

Maximum connection distance

Maximum number of GOTs connected

1 unit

Maximum connection distance

RS-232cable

RS-422

GT15GT15-RS2T4-9P

RS-232

GT15

Serial communication

unit

RS-422converter

Embedded in GOT

Embedded in GOT

Embedded in GOT

GT15-RS4-9S

or

orSerial

communicationunit

GT15-RS2-9P

Temperature controller· OMRON· YAMATAKE· RKC

Temperature controller· OMRON· YAMATAKE· RKC

Temperature controller· RKC

FR-DU04 CONTROL PANELHz

MON EXT PU

AV

REV FWD

D-sub 9 pins (male)

D-sub 9 pins (female)

D-sub 9 pins (male)

CPU direct connectionTemperature controller connection

CNCTemperature controller

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT sideConnection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

1 unit

Inverter connection

Inverter

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

1 unit

Servo amplifier connection

Servo amplifier

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

26 units

Maximum connection distance

CC-Link dedicated cable

CC-Link communication

unit

GT15-75J61BT13-Z (For intelligent device station)

MELDAS C6/C64 *3

(When transient transmitting suggested 5 or less GOTs)

*1: Use NC system software version D0 or later.

GT15

GT15

*1: MELSECNET/H is also used in NET/10 mode.*2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELDAS C6/C64 Reference Manuals.*3: Use NC system software version E0 or later.

*1: Use NC system software version D0 or later.

*1: The number of connected temperature controllers, the maximum connection distance, and the cable and devices vary according to the temperature controller type. For details, refer to the GOT1000 Series Connection Manual.

*1: The cable and devices vary according to the inverter type. For details, refer to the GOT1000 Series Connection Manual.

*1: The number of connected servo units, the maximum connection distance, and the cable and devices vary according to the servo type. For details, refer to the GOT1000 Series Connection Manual.

Fiber-optic cable 63 unitsMaximum connection distance

MELSECNET/10communication unit

Fiber-opticcable

Coaxial cableCoaxialcable

GT15-75J71LP23-Z(Optical loop)GT15-75J71BR13-Z(Coaxial bus)

Maximum number of GOTs connected

31 unitsMaximum connection distance

MELDAS C6/C64 *3

Opticalloop

Coaxialbus

GT15

Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)

MELDAS C6/C64 monitoring and parameter settings can be performed.Log data, set parameters, and display alarms when connected to temperature controllers.

MELSECNET/10 Connection (PC-to-PC Network)

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Connects CC-Link system as intelligent device station.*1CC-Link (ID) connection

Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side

Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.Ethernet connection

F311 cable

128 units

Maximum connection distance

GT15-J71E71-100

100m

MELDAS C6/C64 *110BASE-T cable100BASE-TX cable

Ethernetcable

Ethernet communication

unit

(Suggested less than 16 GOTs)

Maximum segment length

GT15

Up to 32 axes can be controlled when multiple servo amplifiers are connected in multi-drop connection, with capabilities for parameter setting and alarm display.

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

L1 L2 L3

U V W

OPEN

GT11

GT11

GT11

GT11

GT11

GT11

GT11

*1

*1

*2

*2

With QSI optical cable, maximum distance between stations is 1km( )

500mWith 5C-2V coaxial cable, maximum distance between stations is( )

(For CC-Link dedicated cable at 156kbps: )

*2

1200m

Multiple unit connections (GT11) 2unitsM

axim

um number of G

OTs

When connected directly to Mitsubishi PLC and CPU

• The transparent function is not available when multiple units are connected.• Multiple units cannot be connected using the USB interface.

RS-485(4-wire type)

cable

RS-485(2-wire type)

cable

Up to 10 inverters can be connected in multi-drop connection with capabilities for parameter setting and alarm display.

When connecting inverters in multi-drop connection: Max. extension length is ( )

When connecting MELSERVO-J2 in multi-drop connection: Max. extension length is

Extension unit

Extension unit

Extension unit

*1: Handy GOT can only be connected as the second device.

*1: Handy GOT can only be connected as the second device.

*2: Function extension board is required.

*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cycliccommunication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the MELDAS C6/C64 being used.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed.*3: Use NC system software version D0 or later.

When using MELSERVO-J2-Super

[4-wire type]

[2-wire type]

Page 19: Mitsubishi GOT1000

GOT 1

GOT 1

When connected with QCPU (Q mode) Q series Motion controller CPU For connectable CPU models, refer to "Connectable mode list" on page 28.

5units

Max

imum

num

ber of GOTs connected

Number of GOTs

C o n n e c t i o n d i s t a n c e

GOT connection conditions System configuration

0m 13.2m 37m

Cable 1 GOT 1 Middle GOT 2 4~~ Last GOT 2 5~~

Cable 1

Cable 1

GOT 1

GOT 1

Cable 2 Cable 3

GT15-QC B GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2

GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2

GT15-75QBUS2LGT15-QBUS2

GT15-75QBUS2LGT15-QBUS2

06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m

GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Bus connection unitGOT main unit Bus connection unitGOT main unit Bus connection unitGOT main unit

1 unit

2 to 5 units

Within13.2m

More than13.2m

Within13.2m

More than13.2m

PLCMain base

PLCMain base

PLCExtension base

*1

*1

*5

*3

*3

*3

*2 *4 *4 *4

Cable 1

Cable 1

Cable 2

Cable 2

Cable 3

Cable 3

PLCExtension base

*2

*2

Max. 37m

Max. 13.2m

Max. 13.2mMax. 37m

Max. 37m

PLCMain base

PLCMain base

PLCExtension base

Middle GOT 2 4~~ Last GOT 2 5~~

Middle GOT 2 4~~ Last GOT 2 5~~PLCExtension base

A9GT-QCNB

A9GT-QCNB

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75QBUS2LGT15-QBUS2

GT15-75QBUS2LGT15-QBUS2

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2

GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Bus extension connector box

Bus extension connector box

Bus extension connector box

*1: Includes the extension cable length (between base units) when an extension base unit is used. For cable details between main base and extension bese, refer to the MELSEC-Q catalog (L (NA) 08033E-A).

*2: A bus extension connector box is required if the first GOT is installed at a distance of 13.2m or more. If an extension base unit is not being used, install the bus extension connector box at the main base unit.

If an extension base unit is being used, install the bus extension connector box at the extension base unit of the stage that precedes the GOT. (When connected to a Q00JCPU, the box installation at the

main base unit is not possible. In this case, install it at the extension base unit.)

*3: Select cables whose total cable length is 37m or less from the PLC's main base unit to the last GOT.

*4: How to read cable type names, for example, QC B 06: 0.6m is GT15-QC06B.

*5: When 3 or more GOTs are connected, the following restrictions may be applied, depending on the total cable length: The PLC and all GOTs must have the same power supply and must be switched ON and

OFF simultaneously

Number of GOTs

2 or less

3

4

5

○○○○

○○○#

○###

Within 15m Within 20m

○○##

Within 25mTotal cable length

Within 37m

Bus connection is one of the simplest methods to connect one or even multiple GOT's using extension connectors of the base unit. This

connection method provides high performance as well as the fastest response time to Mitsubishi controllers. This solution allows multiple

GOTs terminals to be located when computer link (C24) is not desired. Refer to Notes for bus connection on page 46.

○: Restriction not applied #: Restriction applied

B u s c o n n e c t i o n 1

38 39

Bu

s con

nectio

n

Installation distance of the first unit

from main base *1

Page 20: Mitsubishi GOT1000

B u s c o n n e c t i o n 2

GOT 1

GOT 1

GOT 1 GOT 2

When connected with QnACPU type AnCPU typeFor connectable CPU models, refer to "Connectable mode list" on page 28.

Number of GOTs

GOT connection condition

0m 6.6m 36.6m

Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3

GT15-C NB GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

12 : 1.2m30 : 3m50 : 5m

GT15-C NB12 : 1.2m30 : 3m50 : 5m

GT15-C NB12 : 1.2m30 : 3m50 : 5m

GT15-C EXSS-1100 : 10m200 : 20m300 : 30m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Cable 0

GT15-AC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m

GT15-AC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m

GOT main unit GOT main unit GOT main unit

1 unit

2 units

3 units

Within6.6m

More than6.6m

Within6.6m

Within6.6m

More than6.6m

Cable 1

Cable 0

Cable 1

Max. 6.6m

Max. 6.6m

Max. 36.6m

Max. 30m

Max. 6.6m

Max. 36.6m

Max. 30m

A7GT-CNB

A7GT-CNB

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Bus connectorconversion box

Bus connectorconversion box

Bus connectorconversion box

*1: Includes the extension cable length (between base units) when an extension base unit is used.

For the cables between base unit and extension base unit, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109).

*2: A bus connector conversion box is required if the first GOT is installed at a distance of 6.6m or more.

*3: Select cables so that the total cable length is 36.6m from the PLC's main base unit to the last GOT.

*4: GT15-C EXSS-1:

• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).

• Calculate cable lengths as follows:

GT15-C100EXSS-1: 10m

GT15-C200EXSS-1: 20m

GT15-C300EXSS-1: 30m

*5: Cable length can be read from cable model name. For example, "GT15-AC06B" is 0.6m long.

*6: Select cables so that the total cable length does not exceed 30m.

PLCMain base

PLCExtension base

PLCMain base

PLCExtension base

PLCMain base

PLCExtension base

PLCMain base

PLCExtension base

PLCMain base

PLCExtension base

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

*1

*4

GT15-C EXSS-1100 : 10m200 : 20m

*4

*5 *5 *5 *5

Cable 1

*1

*3

*1

*3

*1

*3

*1 *6

*2

*2

Cable 2

GOT 1

Max. 6.6m

Max. 36.6m

Max. 30m

Cable 0 Cable 1 Cable 2

GOT 2

GOT 2

Max. 6.6m

Max. 36.6m

Max. 30m

Cable 1 Cable 2 Cable 3

GOT 1 GOT 3

C o n n e c t i o n d i s t a n c e

System configuration

AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11

Max

imum

num

ber of GOTs connected

When QnA, AnU, or AnA is connected

Max

imum

num

ber of GOTs connected

When CPUs other than thatshown at left is connected

Bus connection unit Bus connection unit Bus connection unit

40 41

Bu

s con

nectio

n

3units

2units

Installation distance of the first unit

from main base *1

Page 21: Mitsubishi GOT1000

For connectable CPU models, refer to "Connectable mode list" on page 28.

Number of GOTs

C o n n e c t i o n d i s t a n c e

GOT connection conditions System configuration

0m 5m 35m30m

Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3

GT15-A1SC B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-C EXSS-1100 : 10m200 : 20m300 : 30m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Cable 0

GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m

GOT main unit GOT main unit GOT main unit

1 unit

2 units

3 units

Within5 m

More than 5 mWithin 35 m

Within5 m

Within5 m

More than5 m

A7GT-CNB

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-75ABUS2LGT15-ABUS2

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

Bus connectorconversion box

Bus connectorconversion box

Bus connectorconversion box

*1: A bus connector conversion box is required if only one GOT is connected at a distance of 30m or more.

*2: Select cables so that the total cable length is 35m or less from the PLC's main base unit to the last GOT.

*3: Select cables so that the total cable length does not exceed 30m.

*4: GT15-C EXSS-1:• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).• Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m), GT15-C300EXSS-1 (30m).

*5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long.

*4

GT15-C EXSS-1100 : 10m200 : 20m300 : 30m

*4

GT15-C EXSS-1100 : 10m200 : 20m

*4

*5 *5 *5 *5*1

GOT 2

Max. 5m

Max. 5m

Max. 5mMax. 35m

Max. 30m

Max. 30m

Cable 1 Cable 2

GOT 1

Cable 1

GOT 1

GOT 1

Cable 1

Cable 0 Cable 1

Cable 3

GOT 1 GOT 3

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

PLCMain base

PLCMain base

PLCMain base

PLCMain base

PLCMain base

PLCMain base

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

*1

*2

*2

*3

*3

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

GT15-75ABUS2LGT15-ABUS2

GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m

A7GT-CNB 15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-C EXSS-1100 : 10m200 : 20m

*4

Max. 5mMax. 35m

GOT 2

Cable 0 Cable 1 Cable 2

PLCMain base

*1A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

GOT 1

Max. 5mMax. 35m

Max. 35m

Max. 30m

Max. 30m

Max. 30m

Max. 30m

GOT 2

Cable 1 Cable 2

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

GOT 1

GOT 2

Cable 1 Cable 2

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU

RUNPOWER

ERROR

L.CLR

RESET

RUNSTOP

RESET

GOT 1

Without extension base unit

Bus connection unit Bus connection unit Bus connection unit

More than 5 mWithin 35 m

More than 5 mWithin 35 m

*3

B u s c o n n e c t i o n 3

42 43

Bu

s con

nectio

n

Max

imum

num

ber of GOTs connected

When QnAS or A2US(H) is connected

Max

imum

num

ber of GOTs connected

When A1SJ(H) or AnS(H) CPU is connected

3units

2unitsWhen connected with QnASCPU type AnSCPU type

Installation distance of the first unit

from main base

Page 22: Mitsubishi GOT1000

B u s c o n n e c t i o n 4

0m 6m 36m

For connectable CPU models, refer to "Connectable mode list" on page 28.

Installation distance of the first unit

from main base

Number of GOTs

C o n n e c t i o n d i s t a n c e

GOT connection conditions System configurationCable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3

GT15-A1SC B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUS2LGT15-ABUS2

07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m

GT15-C EXSS-1100 : 10m200 : 20m300 : 30m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Cable 0

GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m

GOT main unit GOT main unit GOT main unit

Within6 m

Within6 m

Within6 m

More than6 m

More than6 m A7GT-CNB

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

GT15-75ABUS2LGT15-ABUS2

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-75ABUS2LGT15-ABUS2

GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

Bus connectorconversion box

Bus connectorconversion box

Bus connectorconversion box

*1: Includes the extension cable length (between base units).For "main base unit ⇔ extension base unit" cable details, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109).

*2: A bus connector conversion box is required if the first GOT is installed at a distance of 30m or more.*3: Select cables so that the total cable length is 36m or less from the PLC to the last GOT.

*4: GT15-C EXSS-1:• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).• Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m),

GT15-C300EXSS-1 (30m).

*4

GT15-C EXSS-1100 : 10m200 : 20m300 : 30m

*4

GT15-C EXSS-1100 : 10m200 : 20m

*4

*5 *5 *5 *5*2

Max. 6m

Max. 6m

Max. 36m

GOT 1

Cable 1

GOT 1

Cable 0 Cable 1

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

GOT 1

Cable 1

*2

*1

*1

*1

*1

*1*3

Max. 36m *1*3

GT15-75ABUS2LGT15-ABUS2

GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m

A7GT-CNB 15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

GT15-C EXSS-1100 : 10m200 : 20m

*4

Max. 6m

GOT 2GOT 1

Cable 0 Cable 1 Cable 2

POWER

A1SP60A1S62P

POWER

PLCExtension base

PLCMain base

*2

*1

Max. 36m *1

Max. 6m

GOT 2

Cable 1

Cable 1

Cable 2

Max. 36m *1*3

GOT 1

Max. 6m Max. 30m

Max. 30m

Max. 30m

Max. 30m

Max. 30m

Max. 30m

GOT 3

Cable 1 Cable 2 Cable 3

Max. 36m

*6

*6

GOT 2GOT 1

GOT 2

Cable 2

Max. 36m *1*3

GOT 1

Bus connection unit Bus connection unit Bus connection unit

*5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long. *6: Select cables so that the total cable length does not exceed 30m.

1 unit

2 units

3 units

44 45

Bu

s con

nectio

n

When connected with QnASCPU type AnSCPU type With extension base unit

Max

imum

num

ber of GOTs connected

When QnAS or A2US(H) is connected

Max

imum

num

ber of GOTs connected

When A1SJ(H) or AnS(H) CPU is connected

3units

2units

Page 23: Mitsubishi GOT1000

For connectable CPU models, refer to "Connectable mode list" on page 28.

Number of GOTs

C o n n e c t i o n d i s t a n c e

GOT connection conditions System configuration

0m 1m

Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3

GT15-J2C10B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2

Cable Power supply unit0

GOT main unit GOT main unit GOT main unit

1 unit Within1 m

*2 *2*1

*1

Max. 1m

Max. 6m

GOT 1

Cable 1

Power supply unit

Cable 0

PLCA0J2CM

03: 0.3m

(for horizontal installation)

06: 0.55m

(for vertical installation)

10: 1m

(for extension)

20: 2m

(for extension)

A0J2-PW

*1: The power supply unit is required for connecting GOT.

*2: Cable length can be read from cable model name. For example, "GT15-J2C10NB" is 1m long.

For details regarding connection to an A series motion controller, refer to the "GOT1000 series Connection Manual" (SH (NA)-080532ENG).

15" type

12.1" type

10.4" type

10.4" type

8.4" type

8.4" type

GT1595

GT1585

GT1575

GT1572

GT1565

GT1562

Bus connection unit Bus connection unit Bus connection unit

10 : 1m

Q38Bmain base unit

Q68B extension base unit

QA1S68B extension base unit

GOT

Level of extension base unit

Connection method

231

Number of GOTs

1 unit2 units3 units4 units5 units

○○○○○

○○○○#

○○###

Within 15m Within 15 to 20m

○○○##

Within 20 to 25mTotal cable length

Within 25 to 37m

Connection target CPU Number of GOTs that can be connected

Total Permissible GOT + Intelligent Function Unit*1 Connections

QCPU (Q mode), motion controller CPU (Q series)

QCPU (A mode)QnACPU

ACPU

Motion controller CPU (A series)

*1: This applies to the following intelligent function unit types: AD51 (S3), AD51H (S3), AD51FD (S3), AD57G (S3), AJ71C21 (S1), AJ71C22 (S1), AJ71C23, AJ71C24 (S3/S6/S8), AJ71UC24, AJ71E71 (-S3), AJ71E71N-B2/B5/T/B5T, AJ71E71N3-T, AJ61BT11 (only in intelligent mode), A1SJ71C24 (-R2/PRF/R4), A1SJ71UC24 (-R2/PRF/R4), A1SJ71E71-B2/B5 (-S3), A1SJ71E71N-B2/B5/T/B5T, A1SJ71E71N3-T, A1SD51S, A1SJ61BT11 (only in intelligent mode)*2: Only the A1SD51S intelligent function unit can be connected to the QCPU (Q mode).

AnUCPU,AnACPU,A2US(H)CPUAnNCPU,AnS(H)CPU,A1SJ(H)CPUA0J2HCPUA1FXCPUA273UCPU,A273UHCPU(-S3),A373UCPU(-S3),A173UHCPU(-S1)A171SHCPUN,A172SHCPUN

Max. 5 units

Connection prohibitedMax. 3 unitsMax. 3 unitsMax. 2 unitsMax. 1 unit

Connection prohibited

Max. 3 units

Max. 2 units

5 GOTs + 6 intelligent function units*2

1Total 6 unitsTotal 6 unitsTotal 2 unitsTotal 2 units

1Total 6 units

Total 2 units

Connection target CPU

A1MCPU/A2USCPU(-S1)A2MCPU/Q2ACPUA3MCPU/A4MCPUQ3ACPU/Q4ACPUA0J2HCPU

Max. number of theextension base units

1�3�7�7�1

Use is prohibited

0�0

Communication interface settingSlot No.

2�4

No. of Extension Stages

○: Restriction does not apply.

#: The PLC and all GOTs must have the same power supply, and must all switch ON and OFF simultaneously.

Connection target CPU Number of GOTs Total current consumption

When using Q CPU (Q mode)

For other than QCPU (Q mode) connections

5 units4 units3 units2 units1 unit3 units2 units1 unit

2200mA1760mA1320mA880mA440mA360mA240mA120mA

46 47

Bu

s con

nectio

n

"Number of GOT extension stages" and "slot No." settings

When connected with A0J2HCPU

Max

imum

num

ber of GOTs connected

1unit

Installation distance of the first unit

from main base

B u s c o n n e c t i o n 5

P r e c a u t i o n s

1. Controller and recognition of GOTWhen GOT uses a bus, the CPU recognizes GOT as follows:• QCPU (Q mode) : Intelligent function unit with 16 I/O points.• Other than QCPU (Q mode): Intelligent function unit with 32 I/O points.

2. I/O assignment(1) For connection to the QCPU (Q mode)

Install 1 extension stage (16 points x 10 slots) for a GOT connection. (GOT cannot be assigned to a vacant I/O slot at the main base or any extension base.)Note By setting I/O slots that are not used for GOT as vacant (0 point), "16 points x 1

vacant slot" I/O numbers can be used for other devices.(This setting is specified in the GX Developer's [PLC parameter setting] - [I/O assignment setting].)

Reference See the "Precautions" section, item 9 (For Q mode connection).

(2) For other PLCs connectionAssign the GOT to a vacant I/O slot at the extension base.If there is no extension base, or if the extension base has no vacant slots, install another extension stage, and assign GOT to an I/O slot there. (GOT cannot be assigned to a main base I/O slot.)RReference See the "Precautions" section, item 10. For connection to QnA(S)CPU type

and An(S)CPU type.

1. At GOT power ON(1) System construction

While PLC CPU is in reset status until the GOT is started, sequence program will not starts. It is not possible to construct a system in which the sequence program turns the GOT power ON.

(2) Time period from GOT power ON to PLC run statusA PLC run starts approximately 10 seconds after the GOT starts up following a GOT power ON. When installing a new GOT in an existing system, or when replacing an existing GOT, the system timing should be adjusted to allow for this 10-second PLC startup delay.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

(4) Power ON order when connected to a Q4ARCPU redundant systemReference See item 13. (2) "Power ON order for GOT and Q4ARCPU redundant system"

(5) GOT and PLC power ON order in systems other than those described in items (3) and (4) aboveThe system can be started regardless of whether the GOT power or the PLC power is turned ON first. There is no specified power ON order for GOT and the PLC. However, if a GOT→ PLC power ON order is used, operation occurs as follows.A system alarm (No.402: time-out error) occurs if the PLC is OFF when the GOT power is turned ON. GOT automatically begins monitoring after the PLC CPU is turned ON. Use the system information to reset the alarm.

2. At GOT restarts (OFF→ON)(1) GOT restart (OFF→ON) precaution

Do not restart GOT (OFF→ON) while the PLC power is ON. Before restarting GOT (OFF→ON), always be sure to turn the PLC power OFF. Note GOT1000 series automatic reboot operation

Because GOT1000 series automatically reboot at the conditions of OS installation and Utility setting changes, there is no need for a GOT restart (OFF→ON).• When an OS installation occurs from GT Designer2 or from the CF card.• When the utility setting content is changed.

(2) When GOT power is turned OFF before the user created screens are displayed on GOTCommunication may stop if the GOT power is turned OFF before the user created screens are displayed.If this occurs, restart the PLC CPU and GOT.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

3. The GOT's reset switchThe reset switch on the GOT is disabled when using a bus connection.

4. At PLC power OFF or reset(1) When a PLC power OFF or reset occurs during monitoring

A system alarm (No.402: time-out error) occurs if a PLC power OFF or reset occurs during monitoring. GOT automatically resumes monitoring when a PLC CPU recovery occurs. Use the system information to reset the alarm.

(2) When a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOTCommunication may stop if a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOT. If this occurs, restart the PLC CPU and GOT.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)

Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

5. GOT connection positionThe GOT must always be connected to the last extension of a system. GOT cannot be connected between stages.

6. When GOT is connected to a PLC CPU via bus connection without having installed a communication driverA PLC CPU reset status occurs if GOT is connected to a PLC CPU via bus connection without having installed (at GOT) the basic function OS and a communication driver for the bus connection (communication with the PLC CPU using GX Developer, etc., is disabled). If the above occurs, disconnect GOT's bus connection cable to clear the PLC CPU's reset status.

7. System designWhen the GOT power is turned OFF, the current consumption values shown below are supplied to GOT from the PLC CPU side (power supply unit at main base unit). (GOT operation is disabled when the GOT power is OFF.) Be sure to design the system so that the

"5VDC current consumption of the unit installed at the main base unit" and the "GOT current consumption" total value does not exceed the 5VDC rated output of the power supply unit being used.

8. When assigning GOT input/output signalsDo not use a sequence program, etc., in an attempt to use input/output signals (assigned to the PLC CPU) to the GOT system. If this is attempted, GOT operation cannot be guaranteed.

9. When using QCPU (Q mode)(1) Total cable length restriction when connecting multiple GOTs

The following restrictions apply when 3 or more GOTs are connected.�

(2) When using Q00JCPUThe bus extension connector box can be installed only at an extension base unit. (It cannot be installed at the main base unit.)

(3) When using Q00J/Q00/Q01CPUWhen connected to Q00JCPU by a bus connection, the number of extension stages (including GOT) must not exceed 2.When connected to Q00CPU, Q01CPU by a bus connection, the number of extension stages (including GOT) must not exceed 4.

(4) When using the QA1S6MB type extension base unitAlthough GOTs can be connected to the last stages of all extension base units, the "number of GOT extension stages" setting must be assigned at the end of the QMMB extension base units.The "number of extension stages" for the QA1S6MB extension base unit is assigned at the last stage of the "number of GOT extension stages".

10. For connection to the QnA(S)CPU and An(S)CPU types(1) For connection to the QnASCPU and AnSCPU types

GOT can be connected only at one of the main base unit's extension connectors. (Concurrent GOT connections at both the extension connectors is not permitted.)

(2) For Q4A(R)CPU, Q3ACPU, A3MCPU, and A4UCPUA vacant I/O slot is required within the "maximum number of extension stages" range.

(3) For A0J2HCPUAssign GOT to I/O slots 0 to 3 at the first extension stage.

(4) For CPUs other than items (2) and (3) aboveEven if the maximum number of extension stages are being used, and there are no vacant slots, a GOT can be connected by using the following communication interface settings, provided that there are 32 or more vacant I/O points.

11. When multiple GOTs are connected(1) Composite GOT system

GOTs other than the GOT1000 Series cannot be used together with GOT1000 series.

(2) GOT quantity restrictionThe number of GOTs that can be connected is limited according to the connection target CPU and number of special function units which are installed.

12. When using the PLC CPU in a direct formatNote that a vacant I/O slot's input "x" input cannot be used when a direct I/O control mode is used for the connection target PLC CPU, with a 5m extension cable (GT15-AC50B, GT15-A1SC50NB), and with the first GOT connected to the main or extension base unit. This restriction does not apply when a "refresh" I/O control mode is used. At PLC CPU's equipped with an I/O control mode selector switch, set the switch to the "refresh" format.Note Examples of a vacant I/O slot's "x" input usage

• When input "x" is assigned at the MELSECNET/10 network.• When a vacant I/O slot's input "x" is turned ON/OFF from the computer link unit.• When a vacant I/O slot's input "x" is turned ON/OFF by the GOT touch-switch

function (bit SET/RST/alternate/momentary).

13. For connection to a Q4ARCPU redundant system(1) For a bus connection with a Q4ARCPU redundant system

Connect the GOT to the redundant system extension base unit (A68RB) at the Q4ARCPU redundant system's last stage. A version "B" or later redundant system extension base unit must be used. The redundant system extension base unit's version is indicated in the "DATE" column at the rated plate.Note Q4ARCPU redundant system configuration precautions

GOT will not operate properly in the following system configurations.• When GOT is bus-connected to the bus switching unit (A6RAF) of the

redundant system main base unit (A32RB/A33RB).• When GOT is bus-connected to a version "A" redundant system extension

base unit (A68RB).

(2) Power ON order for GOT and a Q4ARCPU redundant systemThe power ON order for GOT and a Q4ARCPU redundant system should be as follows.1) GOT power ON.2) After the monitor screen displays at GOT, the Q4ARCPU redundant system power switches

ON. As a "time-out" system alarm then displays, use the system information to reset the alarm.

Page 24: Mitsubishi GOT1000

S p e c i f i c a t i o n

Component Names

GT15

GT11

Handy GOT

RS-232 interface

USB interface

Battery

CF card access LED

Environmentally protective cover

Emergency stop switch

CF card interface

RS-232 interface

USB interface

Power supply terminal

RS-422 interface

POWER LED

POWER LED

Key type selector switch

Operation switches (6 switches)

RS-422/232 interface

Touch panel

Grip switch

CF card access switch

CF card interface

CF card cover

Optional function board interface (shipped with cover)

RESET switch

Touch panel

Hook for wall mounting

Rear face protective cover

Hook for neck strap

Optional function board interfaceBattery

Hand strap

Type

Screen size

Resolution

Display size

Number of display characters

Display color

View angle

Contrast adjustment

Intensity

Life

Life *2

Number of touch keys

Key size

No. of simultaneous touch points

Life

Detection distance

Detection range

Detection delay time

C drive

Life (number of writings)

Backed up data

Life

RS-232

USB

CF card

Optional function board

Multi-color display

Extension unit

Drawing software

Simulator function

TFT color display

(High-brightness, wide viewing angle)

SVGA: 800 x 600 [dot]

For 16-dot standard font

: 50 chars. x 37 lines (two bytes)

For 12-dot standard font

: 66 chars. x 50 lines (two bytes)

256 colors / 65536 colors *1

8-step adjustment

Approx. 50,000 hours

(operating ambient temperature: 25°C)

1900 keys per screen

(38 lines x 50 columns matrix resistive type)

Min. 16 x 16 [dots]

(per key) (16 x 8 at final line only)

9 MB built-in flash memory

(for saving project data, extended function OS/optional function OS)

1ch for multi-color display board installation

256 colors

Approx. 40,000 hours or more

Max. 2 points

2.3 [kg]

(excluding the mounting bracket)

10.4"

211(W) x 158(H) [mm]

Cold cathode fluorescent tube (replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time

(time for display intensity to become 50% at operating ambient temperature of 25°C)

1,000,000 or more operations (pressing force of 0.98N or less)

100,000 writings

GT15-BAT type lithium battery (optional)

Clock and maintenance schedule notification data

Approx. 5 years (operating ambient temperature: 25°C)

RS-232, 1ch, Transmission speed: 115200, 57600, 38400, 19200, 9600, 4800 bps Connector shape: D-sub 9-pin (male)

Application: Communication with connected devices, connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)

USB (Full Speed 12Mbps), device, 1ch, Connector shape: Mini-B

Application: Connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)

Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving

1ch for optional function board installation

2ch for communication unit installation

Single tone (tone length is adjustable)

JEM1030 Front face: IP67f *5 Inside panel: IP2X

303(W) x 214(H) x 49(D) [mm]

289(W) x 200(H) [mm]

GT Designer2 Version 2.18U or later

GT Simulator2 Version 2.18U or later

8.4"

171(W) x 128(H) [mm]

241(W) x 190(H) x 52(D) [mm]

227(W) x 176(H) [mm]

1.9 [kg]

(excluding the mounting bracket)

TFT color display (High-

brightness, wide viewing angle)

256 colors / 65536 colors *1

Right/left: 65°, Up: 50°, Down: 60°

380 [cd/m2]

8-step adjustment

9 MB built-in flash memory

(for saving project data,

extended function OS/

optional function OS)

1ch for multi-color display board installation

TFT color display

Right/left: 45°, Up: 30°, Down: 20°

200 [cd/m2]

4-step adjustment

5 MB built-in flash memory

(for saving project data, extended

function OS/optional function OS)

1(m)

Right, left, up, down: 70°

0 to 4 [sec]

Right/left: 50°, Up: 35°, Down: 45°

280 [cd/m2]

2.4 [kg]

(excluding the mounting bracket)

12. 1"

246(W) x 184.5(H)[ mm]

Right/left: 60°, Up: 40°, Down: 50°

350 [cd/m2]

316(W) x 242(H) x 52(D) [mm]

302(W) x 228(H) [mm]

2.8 [kg]

(excluding the mounting bracket)

Right, left, up,down: 85°

380 [cd/m2]

15"

XGA:1024 x 768 [dot]

304.1(W) x 228.1(H) [mm]

For 16-dot standard font

: 64 chars. x 48 lines (two bytes)

For 12-dot standard font

: 85 chars. x 64 lines (two bytes)

Right/left: 75°, Up: 50°, Down: 60°

450 [cd/m2]

Approx. 52,000 hours (operating

ambient temperature: 25°C)

Approx. 50,000 hours or more

3072 keys per screen

(48 lines x 64 columns )

Min. 16 x 16 [dots]

(per key)

Simultaneous touch

prohibited*3 (1 point only)

397(W) x 296(H) x 61(D) [mm]

383.5(W) x 282.5(H) [mm]

4.9 [kg]

(excluding the mounting bracket)

TFT color display

16 colors

Right/left: 45°, Up: 20°, Down: 20°

150 [cd/m2]

4-step adjustment

5 MB built-in flash memory

(for saving project data,

extended function OS/

optional function OS)

VGA:640 x 480 [dot]

For 16-dot standard font: 40 chars. x 30 lines (two bytes)

For 12-dot standard font: 53 chars. x 40 lines (two bytes)

16 colors

Approx. 41,000 hours

(operating ambient temperature: 25°C)

1200 keys per screen

(30 lines x 40 columns matrix resistive type)

Min. 16 x 16 [dots]

(per key)

Item GT1585-STBA

GT1585-STBDGT1595-XTBA

GT1575-STBA

GT1575-STBD

SpecificationGT1575-VTBA

GT1575-VTBD

GT1572-VNBA

GT1572-VNBD

GT1575-VNBA

GT1575-VNBD

GT1565-VTBA

GT1565-VTBD

GT1562-VNBA

GT1562-VNBD

Display

Backlight

Touch panel

Human sensor

Memory*4

Battery

Built-in interface

Buzzer output

Environmentally protective construction

External dimensions (without USB port cover)

Panel cut dimensions

Weight

Supported software package

Performance specifications(GT15)

100 to 240VAC (+10%, -15%)

50/60Hz ±5%

28W or less

20W or less

45A or less (4ms, at max. load)

Within 20ms (100VAC or more)

Noise width 1 µs, and noise frequency 25 to 60 Hz,

by noise simulation with noise voltage 1,500 Vp-p

1500VAC between power supply terminal and ground for 1 minute

31W or less (1290mA/24VDC) 26W or less (1080mA/24VDC)

90VA (at max. load)

24VDC (+25%, -20%)

20W or less (830mA/24VDC)

115A or less (1ms, at max. load)

Within 10ms

Noise width 1 µs, and noise frequency 25 to 60 Hz,

by noise simulation with noise voltage 500 Vp-p

500VAC between power supply terminal and ground for 1 minute

110VA (at max. load)

51W or less

28W or less

50A or less (4ms, at max. load)

26W or less

20W or less

40A or less (4ms, at max. load)

10M½ or higher with an insulation resistance tester (500VDC between power supply terminal and ground)

0.75 to 2 [mm2]

Crimp terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A

0.5 to 0.8 [N·m]

24VDC (+10%, -15%)

4.32W or less (180mA/24VDC)

15A or less (2ms, at max. load)

Within 5ms

Noise width 1 µs, and noise frequency 30 to 100 Hz,

by noise simulation with noise voltage 1,000 Vp-p

500VAC between power supply terminal and ground for 1 minute

10M½ or higher with an insulation resistance tester

(500VDC between power supply terminal and ground)

0.75 to 2 [mm2]*1

Crimp terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A*1

0.5 to 0.8 [N·m]*1

9.36W or less (390mA/24VDC)9.84W or less (410mA/24VDC)

Item GT1585-STBAGT1595-XTBA

GT1575-STBAGT1575-VTBAGT1575-VNBAGT1572-VNBAGT1565-VTBAGT1562-VNBA

Specification

GT1585-STBD

GT1575-STBDGT1575-VTBDGT1575-VNBDGT1572-VNBDGT1565-VTBDGT1562-VNBD

GT1155-QSBDGT1155HS-QSBD

GT1150-QLBDGT1150HS-QLBD

Input power supply voltage

Input frequency

Input maximum voltampere

Power consumption

Rush current

Permissible instantaneous failure time

Noise resistance

Dielectric withstand voltage

Insulation resistance

Applicable wire size

Crimp terminal

Tightening torque (terminal block's terminal screws)

With backlight off

Power supply specifications

Type

Screen size

Resolution

Display size

Number of display characters

Display color

View angle

Contrast adjustment

Contrast adjustment

Intensity

Life

Life *1

Number of touch keys

Key size

No. of simultaneous touch points

Life

C drive

Life (number of writings)

Backed up data

Life

RS-422

RS-422/232

RS-232

USB

CF card

Optional function board

Drawing software

Simulator function

ItemGT1150-QLBDGT1155-QSBD

Specification

GT1155HS-QSBD GT1150HS-QLBD

Display

Backlight

Touch panel

Memory*2

Battery

Built-in

interface

Buzzer output

Environmentally protective construction

External dimensions (without USB port cover)

Panel cut dimensions

Weight

Supported

software package

Performance specifications (GT11)

48 49

Sp

ecificationSTN color display

256 colors

Right/left: 50°,

Up: 50°, Down: 60°

350 [cd/m2]

Approx. 75,000 hours or more

5.7"

QVGA: 320 x 240 [dot]

115(W) x 86(H) [mm]

For 16-dot standard font: 20 chars. x 15 lines (two bytes),For 12-dot standard font: 26 chars. x 20 lines (two bytes)

16-step adjustment

8-step adjustment

Approx. 50,000 hours (operating ambient temperature: 25°C)

Cold cathode fluorescent tube (not replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time

(time for display intensity to become 50% at operating ambient temperature of 25°C)

300 keys per screen (15 lines x 20 columns matrix resistive type)

Min. 16 x 16 [dots] (per key)

Max. 2 points

1,000,000 or more operations (pressing force of 0.98N or less)

3 MB built-in flash memory (for saving project data)

100,000 writings

GT11-50BAT type lithium battery

Clock, alarm history, recipe data

Approx. 5 years (operating ambient temperature: 25°C)

USB (Full Speed 12Mbps), device, 1ch Connector shape: Mini-B Application: communication with

personal computer (for project data uploads/downloads, OS installation, FA transparent function)

Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving

1ch for optional function board installation

Single tone (tone length is adjustable)

GT Designer2 Version 2.18U or later

GT Simulator2 Version 2.18U or late

RS-422, 1ch, Transmission speed: 115200,

57600, 38400, 19200, 9600, 4800 bps

Connector shape: D-sub 9-pin (female)

Application: Communication with connected devices

RS-232, 1ch, Transmission speed: 115200,

57600, 38400, 19200, 9600, 4800 bps

Connector shape: D-sub 9-pin (male)

Application: Communication with connected devices,

connection to personal computer (for project data uploads/

downloads, OS installation, FA transparent function)

JEM1030 Front face: IP67f *3 Inside panel: IP2X

164(W) x 135(H) x 56(D) [mm]

153(W) x 121(H) [mm]

0.7 [kg] (excluding the mounting bracket)

RS-422/232, 2ch (select 1ch when using)

Transmission speed: 115200, 57600, 38400,

19200, 9600, 4800 bps

Connector shape: Round 32-pin (male)

Application: Communication with connected devices

RS-232, 1ch, Transmission speed: 115200,

57600, 38400, 19200, 9600, 4800 bps

Connector shape: Mini-DIN6-pin (female)

Application: Communication with connected devices,

connection to personal computer (for project data uploads/

downloads, OS installation, FA transparent function)

JEM1030 IP65f *4

176(W) x 220(H) x 93(D) [mm]

1.0 [kg] (Main unit only)

STN monochrome (black/white) display

16-tone gray scales

Right/left: 45°,

Up: 20°, Down: 40°

220 [cd/m2]

Approx. 54,000 hours or more

STN monochrome (black/white) display

16-tone gray scales

Right/left: 45°,

Up: 20°, Down: 40°

220 [cd/m2]

Approx. 54,000 hours or more

STN color display

256 colors

Right/left: 50°,

Up: 50°, Down: 60°

350 [cd/m2]

Approx. 75,000 hours or more

*1: 65,536 colors when multi-color display board is installed.*2: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life.*3: Analog resistance film type screen. When 2 points on the screen are touched simultaneously, if a switch is located in

the middle of the 2 points then the switch will be activated. Therefore, avoid touching 2 points on the screen simultaneously.

*4: The internal memory is a ROM that permits new data overwriting without having to delete the existing data.

*5: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X (JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments.

On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.

POWER LED

Power supply terminal

Extension unit interface

Optional function board interface

Multi-color display board interface

CF card interface

S.MODE(OS installation switch)(GT1595 only)

CF card access LED

RESET switch

Battery holder

USB interface

CF card access switch

RS-232 interface

Touch panel

Human sensor (GT1595, GT1585 only)

* This illustration shows the GT1595-XTBA.

*1: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life.*2: The internal memory is a ROM that permits new data overwriting without having to delete the existing data.*3: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X

(JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments.*4: Does not apply when IP65f-rated interface covers on top and rear face are removed.

On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.

*1: Excluding GT115□HS.

0 to 50°C*6

0 to 55°C*6

-20 to 60°C

10 to 90% RH, no condensing

10 to 90% RH, no condensing

Based on JIS B 3502, IEC 61131-2 (147m/s2, 3 times in X, Y and Z directions)

No corrosive gas

2000m or less

Inside the control panel

II or lower

2 or less

Self cooling

If intermittent vibration occurs

If continuous vibration occurs

Frequency

5 to 9Hz

9 to 150Hz

5 to 9Hz

9 to 150Hz

Acceleration

9.8m/s2

4.9m/s2

Single amplitude

3.5mm

1.75mm

Sweep count

Item SpecificationDisplay

Other than display

Storage ambient temperature

Operating ambient humidity*1

Storage ambient humidity*1

Vibration resistance*2

Impact resistance

Operating atmosphere

Altitude*3

Installation location

Overvoltage category*4

Contamination*5

Cooling method

General specifications*1: Wet bulb temperature for STN display type is 39°C or lower.*2: Refer to the Communication Unit User's Manual for vibration re-

sistance specifications when using a MELSECNET/10 commu-nication unit (GT15-75J71LP23-Z, GT15-75J71BR13-Z) or a CC-Link communication unit (GT15-75J61BT13-Z). Communi-cation units specs. are different from GOT specs.

*3: Do not operate or store the GOT unit in pressurized environ-ments where the pressure exceeds the 0m elevation atmos-pheric pressure, as this could result in abnormal operation.

*4: Assuming that the device is connected at some point between a public power distribution network and local system equip-ment. Category II applies to devices that are supplied with pow-er from fixed equipment. The surge withstand voltage is 2500V for devices with ratings up to 300V.

*5: Index that indicates the level of foreign conductive matter in the operating environment of device. Contamination level 2 de-notes contamination by non-conductive matter only, though momentary conductivity may occur due to occasional conden-sation.

*6: 0 to 40°C for GT115□HS.*7: Excluding GT115□HS.

Operating ambi-ent temperature

Based on

JIS B 3502,

IEC61131-2

10 times in each of X, Y, and Z di-rections

Page 25: Mitsubishi GOT1000

GT1155GT1150

Handy GOT

GT1575

GT1565

GT1585GT1595

Size GOT main unit typeGT1595GT1585GT1575GT1565GT1155GT1150

15" type12.1" type10.4" type

8.4" type5.7" type5.7" type

A

BC,DE

When only GOT or a bus connection unit*1 is installedWhen a bus connection unit*2, or a serial communication unit is connectedWhen an RS-422 converter is installedWhen an Ethernet communication unit, a MELSECNET/10 communication unit (coaxial), or a CC-Link communication unit is installedWhen a MELSECNET/10 communication unit (optical) is installed

51 or more

50 or more (26 or more)

50 or more

50 or more (20 or more)

50 or more (20 or more)50 or more (20 or more)

50 or more (36 or more)50 or more (36 or more)73 or more

50 or more (48 or more)

50 or more (20 or more)

80 or more (20 or more)50 or more (20 or more)

100 or more (20 or more)

50 or more (31 or more)50 or more (31 or more)68 or more

50 or more (43 or more)

Item GT1585GT1595 GT1575 GT1565

A383.5302289227

153

B282.5228200176

121

mExternal dimensions

mPanel cut dimensions

mProduct installation interval

When a GOT is installed, the spaces must be provided between other equipment as shown below.

Bus connection unit

Serial communication unit

RS-422 conversionunit

Bus extension connector boxBus connector conversion boxMELSECNET/10 communication unitCC-Link communication unitEthernet communication unit

A +2 0

B +2 0Panel opening

(Unit: mm)

(Unit: mm)

(Unit: mm)

(Unit: mm)

(Unit: mm)

(Unit: mm)

Product nameQ-BUS (1ch) unit, standard modelQ-BUS (2ch) unit, standard modelA-BUS (1ch) unit, standard modelA-BUS (2ch) unit, standard modelQ-BUS (1ch) unit, slim modelQ-BUS (2ch) unit, slim modelA-BUS (1ch) unit, slim modelA-BUS (2ch) unit, slim modelRS-232 serial communication unit(D-sub 9-pin (male))RS-422/485 serial communication unit (D-sub, 9-pin (female))RS-422/485 serial communication unit (Terminal block)RS-232 → RS-422 conversion unit (9-pin)RS-232 → RS-422 conversion unit (25-pin)

Optical loopCoaxial busIntelligent device station

GT15-QBUSGT15-QBUS2GT15-ABUSGT15-ABUS2GT15-75QBUSLGT15-75QBUS2LGT15-75ABUSLGT15-75ABUS2L

GT15-RS2-9P

GT15-RS4-9S

GT15-RS4-TE

GT15-RS2T4-9P

GT15-RS2T4-25P

A9GT-QCNBA7GT-CNBGT15-75J71LP23-ZGT15-75J71BR13-ZGT15-75J61BT13-ZGT15-J71E71-100

Model nameFig. 17Fig. 18Fig. 17Fig. 18Fig. 19Fig. 20Fig. 19�Fig. 20�

Fig. 21

Fig. 21

Fig. 22

Fig. 23

Fig. 24�

Fig. 25�Fig. 26�Fig. 27�Fig. 28�Fig. 29Fig. 30

Externaldimensions

2.32.54.54.5

A0.53.00.83.0

B12111511

C31.529

29.531

D

33.531

EGT15-QBUSGT15-QBUS2GT15-ABUSGT15-ABUS2

Model name

53 47

120

1010

152

135

164

Other device or control panel

C

A

B

DE

Plate thickness: 2 to 4mm

*1: Only applies to the GT15-75QBUSL, GT15-75QBUS2L, GT15-75ABUSL, and GT15-75ABUS2L.*2: Only applies to the GT15-QBUS, GT15-QBUS2, and GT15-ABUS2.· Dimensions shown in parentheses apply when there are no devices nearby (contactor, etc.) which produce radiated noise or heat. Even with these dimensions, however, the ambient temperature must never exceed 55°C. Depending on the unit and cable being used, a cable length longer than the dimension A shown above may be required.

*1: Same dimensions as the A985GOT (-V).*2: Same dimensions as the A975/970GOT (-B).*3: Same dimensions as the F940GOT.

SizeWithout CF Card

5.7" type 50 or more

With CF Card100 or more 50 or more

C A,D

80 or more

B E

100 or more

* The GOT ambient temperature must always be 55°C or less.

*1

*2

*3

*3

E x t e r n a l d i m e n s i o n s

Fig.17

Fig.20

Fig.21

Fig.22

Fig.23

Fig.24

Fig.25

Fig.26

Fig.27

Fig.29

Fig.30

Fig.28

Fig.18

Fig.19

GOT main unit

Communication unit

301

250

316

263

1010

56 6 52

5

227

242

226

175.5

175.5

241

56

190

175

1010

5265

222

303

252

56 49

56

214

199

1010

288

120

120

56

5

v15" type /12.1" type / 10.4" type / 8.4" type

v5.7" type

2.32.33.93.9

AGT15-75QBUSLGT15-75QBUS2LGT15-75ABUSLGT15-75ABUS2L

Model name *4: Dimension A of each communication unit.

*3: Dimension X when mounting GOT *5: Dimension X when mounting GOT

*1: Connector shapes vary according to the model name.*2: Dimensions A to E of each communication unit.

50 51

Extern

al dim

ensio

ns

397

320

296

320

61 65

382

1028

110

1362

176

1620

4

209

168

3.574

6272

50

7518

GOT main unit63 3 B

798

2.5

30.5

21.5

107

A

X

D

C

GOT main unit

A

X

133

107

30.5

21.5

2.5

98

3 B

D

C

E

*1*2*3

*1*2*3

*1*3

*5

*3

*5

*3*5

*1*4

*1*4

X

798 11

2

2.5

30.5

31.5

21.5

3 GOT main unit630.5

9

X

GOT main unit63 30.5

1298

2.5

30.5

21.5

117

29.5

11.5

Front

Bottom

136.8Side

101.

8A

17.6

Front

Bottom

136.8Side

101.

8A

17.6

20.5

3848

44.5

57

RS-232

RS-422

20.5

3848

44.5

57

RS-232

RS-422

20 89.7

64.2

46.7

48

39.54.25 4.25

20155

8071.5

4.25

4.25

Mounting hole

From base unit

102

34X

150

GT15-75IF900

GT

15-7

5IF

900

GOT main unit

150

102

34

GT15-75IF900

GT

15

-75IF

900

When F type connector is installed

X

150

102

39

GT15-75IF900

GT

15-75IF900

GOT main unit

X

2.5

21

3GOT main unit63

0.5

98 112

0.47

8

30.5

21.5

X

To bus connection unit

Whenthe connector

is installed

Whenthe connectoris installed

GOT main unit

8.4" type10.4" type, 12.1" type, 15" type

8.4" type10.4" type, 12.1" type, 15" type

2321

15.513.5

GT15-QCMBGT15-QCMBSGT15-CMNBGT15-ACMBGT15-A370CMB-S1GT15-A370CMBGT15-A1SCMBGT15-A1SCMNBGT15-CMEXSS-1*1

GT15-EXCNBGT15-CMBSGT15-J2C10B

*1: The GT15-CMEXSS-1 is a set product consisting of the GT15-EXCNB and GT15-CMBS. (See Fig. A)

GT15-EXCNB (Fig. 8) GT15-CMBS (Fig. 9)

(Unit: mm)

(Unit: mm)

Fig. A

PLC side GOT side

~

Cable model name0.6, 1.2, 3, 5, 10 m15, 20, 25, 30, 35 m1.2, 3, 5 m0.6, 1.2, 3, 5 m1.2, 2.5 m1.2, 2.5 m0.7, 1.2, 3, 5 m0.45, 0.7, 3, 5 m10.6, 20.6, 30.6 m0.5 m0.7, 1.2, 3, 5, 10, 20, 30 m1 m

Fig. 1Fig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7

Fig. 8 + Fig. 9Fig. 8Fig. 9

Fig. 10

Cable length (L) External dimensions

GT01-C30R4-25PGT01-CMR4-25PGT01-CMR4-8P

Cable model name3 m10, 20, 30 m1, 3, 10, 20, 30 m

Fig. 11Fig. 12Fig. 13

Cable length (L) External dimensions

GT01-C30R2-6PGT01-C30R2-9SGT01-C30R2-25P

Cable model name3 m3 m3 m

Fig. 14Fig. 15Fig. 16

Cable length External dimensions Fig.13

Fig.12

Fig.11

Fig.5

Fig.4

Fig.3

Fig.2

Fig.1

Fig.10

Fig.9

Fig.8

Fig.7

Fig.6

Bus connection cable

RS-422 cable

RS-232 cable

5016

35

53 16

55

3000

Ø7

16 50 53L

35 55

Ø7

16

Ø15 x 28.5Ø6

50 4016

35

13

13

L16 50 533000

35

16

55

Ø6

16 50 503000

35

16

35

Ø6

10

42

34.2145

L95

Cable approx. Ø10

Ferrite core, approx. Ø35 x 40, red holder tube

Ferrite core, approx. Ø35 x 40, green holder tube

A0J2-PW side

GOT side

Cable approx. Ø8.01000

7033 12.4

49.9

100

12.433

49.9 C

ON

1

1000 FG cable

500Cable approx. Ø9.0PLC side GOT side

CO

N2

GO

T side 60

75 20.5

12.4 33110

L50

60 20

49.9

58

Ferrite core, approx. Ø35 x 40, green holder tube

Motion controller sideA7GT-CNB side

Cable approx. Ø8.0

12.4 33

110

49.9

L

Cable approx. Ø8.0

Ferrite core, approx. Ø35 x 40, green holder tube

50

12.4 33110 Cable approx. Ø8.0

L50

60 20

49.9

Ferrite core, approx. Ø35 x 40, green holder tube

PLC sideA7GT-CNB side

58

20 60 L50

Cable approx. Ø17.070

Ferrite core, approx. Ø32 x 16, green holder tube

58

12.4

49.9

33160

L

Cable approx. Ø8.0 110

Ferrite core, approx. Ø35 x 40, green holder tube

20 60

58

70 Cable approx. Ø8.0

Ferrite core, approx. Ø35 x 40, green holder tube

PLC sideGOT side

5033

12.4

49.9

L

12.4

49.9

33 L

Cable approx. Ø9.0

FG cable

Ferrite core, approx. Ø35 x 40, blue holder tube

110160

CO

N1

CO

N2

GO

T side

16 50 40 13

13

3000

35

Ø7Ø20 x 28

Fig.16

Fig.15

Fig.14

Page 26: Mitsubishi GOT1000

Model

Function Description Page

GT11GT15

GT1585-STBM

GT1575-STBM

GT1575-VTBM

GT1565-VTBM

GT1155-QSBD

GT1150HS-QLBD

Bus connection

CPU direct connection

Computer link connection

MELSECNET/10 connection

CC-Link connection (ID/via G4)

Ethernet connection

Connection to

other brand PLCs

Microcomputer connection

Temperature controller connection

Inverter connection

Servo amplifier connection

CNC connection

Standard memory capacity

Total memory capacity when

using option (standard + option)

65536 colors

256 colors

16 colors

16 gray scales

1024 x 768 dot

800 x 600 dot

640 x 480 dot

320 x 240 dot

Number of touch keys

(line x row)

RS-232 interface

RS-422 interface

RS-422/232 interface

USB (USB (Full Speed 12Mbps

device 1ch (Mini-B))

CF card interface (Compact

Flash slot 1ch (TYPE 1))

Optional function

board interface (1ch)

Extension unit interface (2ch)

Vertical display

Clock function

Buzzer output

Human sensor

Backlight OFF

detection function

Environmentally protective construction

Boot OS installation

OS installation*4

Project data downloads

/uploads *5

Resource data uploads *6

FA transparent function

Multi-channel function

Gateway function

Base screen

Superimposed window display

Overlap window display

Supported image data

format

Standard font

High-quality font

TrueType font

Windows ® font

Simplified Chinese [GB]

/ Mincho (GB2312)

Traditional Chinese [Big5]

/ Gothic font

Part (object + figure) Layer function

For connectable PLCs, refer to

the "Connectable model list" on page 30

Communication protocol (15 type) compatible

CPU direct connection

MELSECNET/10 connection

CC-Link (ID) connection

Ethernet connection

Optional expansion memory function board.

Requires (GT15-QFNBMM) + CF card.

Multi-color display board is required.

For PC communication (project data downloads/

uploads, OS installation, FA transparent function)

For data transmission and data saving

For optional function board installation

(only for GT15 with expansion memory)

For communication unit installation

GT15 requires a battery (GT15-BAT)

to save clock data.

Monotone (tone length is adjustable)

GT15 backlight is replaceable.

GT1155-QSBD features a long-life backlight.

Via USB or RS-232, using CF card

Via Ethernet (GT15 only)*7,

Via USB or RS-232, using CF card

Via USB or RS-232

Basic GOT display screen

Composite display windows on the base screen

Pop-up window

BMP image data

JPEG image data

DXF data

Re-quired

Required

Required

Re-quired

Re-quired

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

9MB

Max.

57MB

v

v

v

3072

(48 x 60)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

9MB

Max.

57MB

v

v

v

1200

(30 x 40)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

5MB

Max.

53MB

v

v

1200

(30 x 40)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Via G4 only

v

v

v

v

v

v

3MB

v

v

300

(15 x 20)

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Via G4 only

v

v

v

v

v

v

3MB

v

v

300

(15 x 20)

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Via G4 only

v

v

v

v

v

v

3MB

v

v

300

(15 x 20)

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Via G4 only

v

v

v

v

v

v

3MB

v

v

300

(15 x 20)

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

9MB

Max.

57MB

v

v

v

1900

(38 x 50)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

9MB

Max.

57MB

v

v

v

1900

(38 x 50)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

9MB

Max.

57MB

v

v

v

1200

(30 x 40)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

5MB

Max.

53MB

v

v

1200

(30 x 40)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

5MB

Max.

53MB

v

v

1200

(30 x 40)

v

*3

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Required

Re-quired

Re-quired

P.28

P.8, 28

P.28

P.11,48

P.19,48

P.48

P.21,48

P.48

P.48

P.20

P.20

P.9,55

P.10

P.11

P.19

P.11

P.12

P.12

P.13

P.22

P.15

P.14

P.15

P.13

P.24

P.25

P.24

P.16

P.18

12.1" 10.4" 10.4" 8.4" 5.7"5.7"SVGASVGA

GT1595-XTBA

15"XGA VGA

GT1575-VNBM

10.4"VGA

GT1572-VNBM

10.4"VGA VGA

GT1562-VNBM

8.4"VGA QVGA QVGA

GT1150-QLBD

5.7"QVGA

GT1155HS-QSBD

5.7"QVGA

*1: Function contents, such as the number of points to set and the destination to save files, vary according to the model.*2: For details, see the "Notes for use" section on page 54.*3: The RS-232 interface is used as an RS-422 interface by installing an RS-422 converter. *4: "OS" refers to the basic functions, communication drivers, extended functions, and optional functions.*5: "Project data" refers to user screen data (base screen, window screen), components, advanced recipes, comments, common settings, high-quality font, and the boot logo.*6: "Resource data" refers to the alarm log files (advanced alarms, alarm history), recipe files, advanced recipe files, data log files, screen transition information files, and hard copy files. The GT11 supports only the alarm log file (alarm history).*7: The GOT with basic functions installed must be equipped with an Ethernet communication unit.*8: Only 16-dot fonts (standard / high-quality Mincho font) are available.*9: Settings of the logging function are required in order to use historical trend graph function. In addition, the optional function board and optional function OS (Logging) must be installed.*10: Structural restrictions apply.

*1

F u n c t i o n l i s t f o r e a c h m o d e l

53

List o

f pro

du

cts

Con

nect

ion

conf

igur

atio

nU

ser

me

mo

ry

cap

aci

tyD

ispl

ay

colo

rsR

esol

utio

nT

ouch

keys

Inte

rnal

inte

rfac

eO

ther

Spe

cific

atio

nsM

ain

unit

func

tions

Har

dwar

e sp

ecifi

catio

nsS

cree

n de

sign

Cat

egor

y

Model

Function Description GT1585-STBM

GT1575-STBM

GT1575-VTBM

GT1565-VTBM

GT1155-QSBD

GT1150HS-QLBD

Screen switching

Station No. switching

Multilingual support function

Password

System information

Connected device setting

Boot logo

Comment registration

Parts registration

Data operation function

Offset function

Security function

Lamp display

Touch switch

Numerical display/input

Data list display

ASCII display/input

Kana-kanji conversion function

Clock display

Comment display

Advanced alarm

observation/display

Alarm list display

Alarm history display

Parts display

Parts movement

Panel meter display

Level display

Trend graph

Historical trend graph*9

Line graph

Bar graph

Statistical graph

Scatter graph

Status observation function

Advanced recipe

Recipe function

Time action function

Hard copy function

(File saved in CF card)

Bar-code function

Screen call function

Logging function

Script function

System monitor function

List editor for A

List editor for FX

Ladder monitor function

Intelligent unit monitor function

Q motion monitor function

Servo amplifier monitor function

Network monitor function

CNC monitor function

Maintenance notification function

GT Works2 Version2

GT Designer2 Version2

GT Simulator2 Version2

GT Converter2 Version2

Multilingual support device switches

the language of objects with comment groups.

Channel No. driver setting is required

Displays the desired image (BMP) at GOT startup.

1 basic comment per project*8

255 comment groups per project

ASCII inputs limited to 16 chars.

Lower/higher bit display order is selectable.

Advanced user alarm / advanced system

alarm / advanced alarm popup window

User alarm display / system alarm display

File saved in CF card (BMP, JPEG)

CF card is required

Project script

Screen script

Object script

Use the GT15-QFNB (MM) for

the Q/QnA ladder monitor function.

Battery (GT15-BAT) is required

For items shipped with the unit,

see the "Device List" (page 56).

GOT1000 compatible drawing software

GOT1000 compatible simulation software

Easy data convert function

Converts GOT800 series, GP-PRO/

PBIIIC-Package03 to GT15, A900 data

Required

*9

Required

Required

Required

Required

Required

Required

Re-quired

Required

Required

Required

Required

Required

Required

Required

*9

Required

Required

Required

Required

Required

Required

Required

Required

Re-quired

Required

Required

Required

Required

Required

12.1" 10.4" 10.4" 8.4" 5.7"5.7"SVGASVGA

GT1595-XTBA

15"XGA VGA

GT1575-VNBM

10.4"VGA

GT1572-VNBM

10.4"VGA VGA

GT1562-VNBM

8.4"VGA QVGA QVGA

GT1150-QLBD

5.7"QVGA

GT1155HS-QSBD

5.7"QVGA

*1

Com

mon

set

tings

Obj

ect s

ettin

gO

ther

Mai

nten

ance

func

tions

Sof

twar

eS

cree

n de

sign

Cat

egor

y

52

*6 *6 *6 *6

*10 *10

GT11GT15

Opt

iona

l Fu

nctio

n B

oard

Exte

nded

/Opt

ional

Func

tion

OS In

stalla

tion

*2*2

Page

Opt

iona

l Fu

nctio

n B

oard

Exte

nded

/Opt

ional

Func

tion

OS In

stalla

tion

*2*2

Re-quired

Re-quired

Page 27: Mitsubishi GOT1000

Total: Up to 4ch

Total: Up to 4ch

Total: Up to 2ch

Total: Up to 2ch

Total: Up to 2ch

Multi-channel*2

Maintenance notification function

Simplified Chinese [GB] Mincho font

Traditional Chinese [Big5] Gothic font

Recipe

Advanced recipe

Logging

Kana-Kanji conversion function

Object script

Gateway (server, client)

Gateway (mail)

Gateway (FTP)

List editor for MELSEC-A

List editor for MELSEC-FX

Ladder monitor for MELSEC-Q/QnA*2

Ladder monitor for MELSEC-A

Ladder monitor for MELSEC-FX

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor function

CNC monitor function

System monitor

Bar-code

Optional functions*1

Extended functions

*3

*3

1280

1920

100

1241

740

1223

360

100

100

64

1058

1058

1082

523

592

384

607

524

324

588

746

84

None

None

None

None

*4

None

None

None

None

None

None

None

*4

*4

None

None

None

None

None

None

None

None

*4

*4

FunctionsGT15 GT11

Available user data space (KB)

When using multi-channel function

[Table A]When using the GT15

When using the GT11

For project datamGT Designer È GT Designer2 compatibility*

Project data created in GT Designer can be used in GT

Designer2.

mGOT900 series È GOT1000 series compatibility*• Using data from the GOT-A900 series

GOT900 series project data can be used at the GOT1000 series.

• Using data from the GOT-F900 seriesData created in GT Designer and GT Designer2 can be used.

Data must first be converted to GOT-A900 series data, and then

to GOT1000 series data.*: Some data and function items cannot be used (not compatible).

mBus connection cables• The GOT900 series bus connection cable cannot be used by

the GOT1000 series.

• The GOT1000 series bus connection cable cannot be used by

the GOT900 series.

mRS-422 and RS-232 cables• The GOT900 series RS-422 and RS-232 cables cannot be

used by the GOT1000 series.

• The GOT1000 series RS-422 and RS-232 cables cannot be

used by the GOT900 series.

mGOT900 series È GOT1000 series compatibility• The A985GOT(-V) and the GT1585, the A975/970GOT(-B) and

the GT1575, the F940GOT and the GT1155/1150, have the

same panel cut dimensions. Therefore, it is not necessary to

change the mounting holes when replacing an A985GOT(-V),

A975/970GOT(-B), or F940GOT with a GOT1000 series unit.

Panel cut dimensions

N o t e s f o r u s e

mWhen using optional functions & extended functionsIn order to use the optional functions shown in "Table A", an optional function board or an optional expansion memory function board must be installed, regardless of the project data capacity and the available user data space.Depending on the functions used, the OS installation may reduce the available user data space.Refer to "Table A" for the amount of user data space corresponding to the optional function OS and the extended function OS.If there is insufficient user space available, an optional expansion memory function board should be selected.

mSelect according to project data capacityA CF card and an optional function board with expansion memory are required if the project data size exceeds the standard memory capacity*1.Project data should be downloaded to Drive "A" (CF card).• Selecting a CF cardSelect a CF card that exceeds the project data capacity*2.

• Selecting an optional expansion memory function boardSelect an optional function board with expansion memory that has the larger capacity than it is indicated as follows*2: [project data size] - [standard memory capacity*1].

*1:Standard memory capacity vary according to the the model. For details refer to the specification on page 48.*2: This is a general guideline.

mWhen using optional functions & extended functions

Install an optional function board in order to use the "Table A" optional functions.

mAcceptable combinations The following connection combinations are compatible with the multi-channel function.

mCommunication driver A communication driver must be installed for each of the connection configurations. Communication drivers for the 2nd and subsequent channels will be installed in the user area.

*1: The serial connection includes the following connection configurations:· CPU direct connection· CC-Link connection (via G4)· Other brand PLC connection· Inverter connection· CNC connection (CPU direct connection)· Computer link connection· Microcomputer connection· Temperature controller connection· Servo amplifier connection

*2: Because the following communication units cannot be connected together with other communication units (serial communication units, Ethernet communication units, etc.), GOT's built-in RS-232 interface must be used for serial connections. Therefore, the barcode function, the FA transparent function (via RS-232), the Ethernet download function, and the gateway function cannot be used. · Bus connection unit (slim type): GT15-75QBUS(2)L, GT15-75ABUS(2)L· MELSECNET/10 communication unit: GT-15-75J71LP23, GT-15-75J71BR13-Z· CC-Link communication unit: GT15-75J61BT13-Z

mOptional function board Use of the GT15-QFNB (MM) optional function board is required.The GT15-FNB cannot be used.

*1: GT15···Use the optional function board (GT15-QFNB/GT15-FNB) or the optional expansion memory function board (GT15-QFNBMM).GT11···Use the optional function board (GT11-50FNB).

*2: The GT15-FNB does not support the multi-channel function and the MELSEC-Q/QnA ladder monitor function. These functions require the GT15-QFNB (MM).

*3: Installation of the optional function OS is not required.*4: Requires installation of the optional function OS and extended function OS, but the user data area cannot be used.

54 55

No

tes for u

se

For cable

CF card & optional function board selection

Forward compatibility

· Data transmission (also possible at GT11)

· Advanced alarm

· Alarm history (also possible at GT11)

· Advanced recipe

· Recipe

· Logging

· Historical trend graph

· Parts display

· Parts movement

· Hardcopy

The CF card can be used for the following GT15 functions:

Bus connection: 1ch(When using GT15-QBUS (2) or GT15-ABUS (2))Serial connection*1: 1 to 3ch

Bus connection: 1ch(When using GT15-75QBUS (2) or GT15-75ABUS (2) L)Serial connection*1: 1ch

MELSECNET/10 connection (PC-to-PC Network): 1chSerial connection*1: 1ch

CC-Link (ID) connection: 1chSerial connection*1: 1ch

Ethernet connection: 1chSerial connection*1: 1 to 3ch

Serial connection only*1: 1 to 4ch

*2

*2

*2

Total: Up to 4ch

Personal computer

OS

CPU Required memoryFree hard disk spaceDisk driveDisplay colorsDisplay

Others

For installationFor operation

PC/AT compatible machine running Windows®Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions)Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions)Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions)*2Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*2Pentium 200MHz or higher64MB or more300MB or more100MB or moreCD-ROM disk driveHigh color (16 bit) or moreResolution 800 x 600 dot or more• Internet Explorer Ver. 5.0 or later must be installed.• Mouse, keyboard, printer, CD-ROM drive which are compatible with the above OS.

Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*1*2

Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*1*2

Pentium II 300MHz or higher128MB or more

Item Description

GT Designer2 (English version) operating environment

GT Simulator2 (English version) operating environment

*1: The following functions are not supported: Compatible Mode, Fast User Switching, Desktop Theme (Font) Change, Remote Desktop.*2: Administrator authority is required to install GT Designer2 on the following systems: Windows NT® Workstation 4.0, Windows® 2000 Professional, Windows® XP Professional, Windows® XP Home Edition; Administrator authority is required to operate GT Designer2 on Windows® XP Professional and Windows® XP Home Edition.

QCPU (A mode), ACPU or motion controller CPU (A series)QCPU (Q mode) (except Q00J/Q00/Q01CPU), QnACPU, FXCPUQ00J/Q00/Q01CPUQ12PHCPU, Q25PHCPUQ12PRHCPU, Q25PRHCPU

PLC CPUs to be simulated Software versionVersion5 "A" Edition or laterVersion5 "E" Edition or laterVersion6.00A or laterVersion6.10L or laterVersion6.20W or later

DescriptionItemPersonal computer

OS

CPURequired memoryFree hard disk space*1

Disk drive

Display colors

Display

Software

For installation (product only) For operation

For project data creation/editing

When GX Simulator is used

PC/AT compatible machine running Windows®Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions)Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions)Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions)*2*3

Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*3Pentium 200MHz or higher64MB or more250MB or more (For product operation and manual reference: 400MB or more)200MB or moreCD-ROM disk driveGT15 simulator: High Color (16-bit) or moreGT11 simulator: 256 colorsResolution 800 x 600 dot or moreGT Designer2*5

• GX Simulator of the following version is required depending on CPU.*6

Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*3*4

Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*3*4

Pentium II 300MHz or higher128MB or more

*1: A separate available space is required when using GT Designer2, GX Developer, and GX Simulator.*2: Use WindowsNT® Workstation 4.0 with Service Pack3 or later installed. *3: Administrator authority is required to install GT Simulator2 in the following operating systems.

• WindowsNT® Workstation 4.0• Windows® 2000 Professional• Windows® XP Professional• Windows® XP Home Edition

Moreover, administrator authority is required to use GT Simulator2 in the following operating systems.• Windows® XP Professional• Windows® XP Home Edition

*4: The following functions are not supported.• "Compatibility mode", "user account", "desktop appearance", and "remote desktop"

*5: Use a GT Designer2 that is included in the same GT Works as GT Simulator2.*6: Use only same-language GT Simulator2, GX Developer, and GX Simulator versions.

Page 28: Mitsubishi GOT1000

Model name Specification Applicable modelGT15 GT11

GT15 GT11

Backlight

Optional function board

Multi-color display board

Protection sheet

USB IP67f rated port cover

Emergency stop switch guard

Stand

CF card

Memory card adaptor

Attachment

Battery

GT15-90XLTTGT15-80SLTTGT15-70SLTTGT15-70VLTTGT15-70VLTNGT15-60VLTTGT15-60VLTNGT15-FNBGT15-QFNBGT15-QFNB16MGT15-QFNB32MGT15-QFNB48MGT11-50FNBGT15-XHNBGT15-90PSCBGT15-90PSGBGT15-90PSCWGT15-90PSGWGT15-80PSCBGT15-80PSGBGT15-80PSCWGT15-80PSGWGT15-70PSCBGT15-70PSGBGT15-70PSCWGT15-70PSGWGT15-60PSCBGT15-60PSGBGT15-60PSCWGT15-60PSGWGT11-50PSCBGT11-50PSGBGT11-50PSCWGT11-50PSGWGT11H-50PSCGT15-UCOVGT11-50UCOVGT11H-50ESCOVGT15-90STANDGT15-80STANDGT15-70STANDA9GT-50STANDGT05-MEM-32MCGT05-MEM-64MCGT05-MEM-128MCGT05-MEM-256MCGT05-MEM-ADPCGT15-60ATT-96GT15-60ATT-97GT15-BATGT11-50BAT

Backlight

Optional function board (A/FX ladder monitor)

Optional function board (Q/QnA/A/FX ladder monitor)

Optional function boardMulti-color display board for 65536 color display

Protection sheet for 15" type

Protection sheet for 12.1" type

Protection sheet for 10.4" type

Protection sheet for 8.4" type

Protection sheet for 5.7" type

Protection sheet for 5.7" type (For Handy GOT)

IP67f rated port cover (for replacement) for unit front USB interface

To prevent operational errorDebugging stand for 15" typeDebugging stand for 12.1" typeDebugging stand for 8.4"/10.4" typeDebugging stand for 5.7" type32MB Flash ROM64MB Flash ROM128MB Flash ROM256MB Flash ROMCF card → memory card (TYPE II) conversion adaptor

Attachment for 8.4" type

Data backup battery for clock and maintenance notificationData backup battery for clock, alarm history, and recipes

For 15" type High-brightness, wide viewing angle TFT (XGA)For 12.1" type High-brightness, wide viewing angle TFT (SVGA) For 10.4" type High-brightness, wide viewing angle TFT (SVGA)For 10.4" type High-brightness, wide viewing angle TFT (VGA)For 10.4" type TFT (VGA)For 8.4" type High-brightness, wide viewing angle TFT (VGA)For 8.4" type TFT (VGA)(Without expansion memory)(Without expansion memory)16MB expansion memory32MB expansion memory48MB expansion memory

Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)

A960GOT→ GT1565/GT1562A97 GOT→ GT1565/GT1562

Product name

Options

L i s t o f p r o d u c t s

Product name Model name Specification Applicable model

Bus connection unit

Serial communication unit

RS-422 conversion unit

Ethernet communication unitMELSECNET/10 communication unitCC-Link communication unit

GT15-75QBUSLGT15-75QBUS2LGT15-QBUSGT15-QBUS2GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2GT15-RS2-9PGT15-RS4-9SGT15-RS4-TEGT15-RS2T4-9PGT15-RS2T4-25PGT15-J71E71-100GT15-75J71LP23-Z *2

GT15-75J71BR13-Z *2

GT15-75J61BT13-Z *2

Q-BUS (1ch) unit slim model for QCPU (Q-mode) Q-BUS (2ch) unit slim model for QCPU (Q-mode)Q-BUS (1ch) unit standard model for QCPU (Q-mode)Q-BUS (2ch) unit standard model for QCPU (Q-mode)A-BUS (1ch) unit slim model for QnA/ACPUA-BUS (2ch) unit slim model for QnA/ACPUA-BUS (1ch) unit standard model for QnA/ACPUA-BUS (2ch) unit standard model for QnA/ACPURS-232 serial communication unit (D-sub 9-pin (male))RS-422 / 485 serial communication unit (D-sub, 9-pin (female))*1

RS-422 / 485 serial communication unit (Terminal block)*1

RS-232 → RS-422 conversion unit

Ethernet (100Base-TX/10Base-T) unitOptical loop unitCoaxial bus unitIntelligent device station unit

1 connector2 connectors1 connector2 connectors1 connector2 connectors1 connector2 connectors

RS-422 connector 9-pinRS-422 connector 25-pin

Handy GOT

Handy GOT

Communication interface

56 57

List o

f pro

du

cts

Model name Screen size [resolution] Display device Display color Power source Memory size

GT1595

GT1585

GT1575

GT1565

GT1155

GT1150

Handy GOT

GT15

GT11

GT1595-XTBA

GT1585-STBA

GT1585-STBD

GT1575-STBA

GT1575-STBD

GT1575-VTBA

GT1575-VTBD

GT1575-VNBA

GT1575-VNBD

GT1572-VNBA

GT1572-VNBD

GT1565-VTBA

GT1565-VTBD

GT1562-VNBA

GT1562-VNBD

GT1155-QSBD

GT1150-QLBD

GT1155HS-QSBD

GT1150HS-QLBD

15" XGA [1024 x 768 dots]

12.1" SVGA [800 x 600 dots]

10.4" SVGA [800 x 600 dots]

10.4" VGA [640 x 480 dots]

8.4" VGA [640 x 480 dots]

5.7" QVGA [320 x 240 dots]

TFT color display(High-brightness, wide viewing angle)

TFT color display(High-brightness, wide viewing angle)

TFT color display(High-brightness, wide viewing angle)

TFT color display(High-brightness, wide viewing angle)

TFT color display

TFT color display(High-brightness, wide viewing angle)

TFT color display

STN color display

STN monochrome display

STN color display

STN monochrome display

256 colors /

65,536 colors (optional)

256 colors /

65,536 colors (optional)

256 colors /

65,536 colors (optional)

256 colors /

65,536 colors (optional)

256 colors

16 colors

256 colors /

65,536 colors (optional)

16 colors

256 colors

16-tone black/white adjustment

256 colors

16-tone black/white adjustment

100-240VAC

100-240VAC

24VDC

100-240VAC

24VDC

100-240VAC

24VDC

100-240VAC

24VDC

100-240VAC

24VDC

100-240VAC

24VDC

100-240VAC

24VDC

24VDC

9MB

5MB

5MB

9MB

5MB

3MB

GOT main units

Manual Name Content Catalog No.GT Designer2 Version2 Basic Operation/

Data Transfer Manual <For GOT1000 Series>

GT Designer2 Version2 Screen Design Manual

<For GOT1000 Series>

GOT1000 Series Connection Manual

GOT1000 Series Extended/Option Functions Manual

GOT1000 Series Gateway Function Manual

GT15 User's Manual

GT11 User's Manual

GOT1000 Handy GOT User's Manual

GT Simulator2 Version2 Operation Manual

GT Converter2 Version2 Operation Manual

Basic software installation information, basic design techniques, and data transfer to a terminal

Programming manual, including instruction for objects, specifications

System configurations and procedure to create customized cables

Detailed Extended Functions information

Detailed Gateway Information, including specifications, setting, and configurations

General specification overview, parts and settings, external dimensions, mounting, wiring,

optional interfaces

General specification overview, parts and settings, external dimensions, mounting, wiring,

optional interfaces

General specification overview, parts and settings, external dimensions, wiring, optional interfaces,

in addition to explanations of utility, system configurations, and cable fabrication

GT Simulator2 specifications and operating instructions

GT Converter2 operating instructions

SH-080529ENG

SH-080530ENG

SH-080531ENG

SH-080532ENG

SH-080544ENG

SH-080545ENG

SH-080528ENG

JY997D17501A

JY997D20101A

SH-080546ENG

SH-080533ENG

Manuals

Software Software Version RemarksIncluded product

Drawing SoftwareGT Designer2 Ver. 2

Simulation GT Simulator2 Ver. 2

Easy data conversion GT Converter2 Ver. 2

SoftGOTGT SoftGOT2

GT Designer2

Version2

GT Works2

Version2

License key forGT SoftGOT2 *1*2

License key FD forGT SoftGOT2 *1*2

SW2D5C-GTD2-E

SW2D5C-GTD2-EV

SW2D5C-GTWK2-E

SW2D5C-GTWK2-EV

A9GTSOFT-LKEY-P

SW5D5F-SGLKEY-E

English version

English version

English version

Version upgrade software (upgrade GT Designer2 to the latest version)

Version upgrade software (upgrade GT Works2 to the latest version)

DOS/V License key (for D-sub 25-pin and parallel port)

License registration package for personal computer CPU unit

Software

*1: Soon to be supported by the GOT1000 Series.

*2: GT SoftGOT2 License key is required for every DOS/V computer, and GT SoftGOT2 license key FD is required for every personal computer CPU unit.

*1

*1

NEWNEWNEW

NEWNEW

NEWNEW

NEW

NEW

NEW

NEW

NEWNEWNEWNEW

NEW

NEWNEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

coming soon

coming soon

coming soon

GT15 9 5 - X T B AModel name explanation Model name explanation (Options)

GT 15 - 90 XLTT

Full-specification model covering a broad range of applications to be used as stand-alone and network access control.Stand-alone model with full of basic functions.

GT15GT11

Screen sizeCode98765

15"12.1"10.4"

8.4"5.7"

Display colorCode520

256 colors or more16 colors

16-tone gray scales

Mounting typeCodeNoneHS

Panel mounted typeHandy type

ResolutionCodeXSVQ

XGA (1024 x 768 dot)SVGA (800 x 600 dot)VGA (640 x 480 dot)QVGA (320 x 240 dot)

Display deviceCode

T

NSL

TFT color (High-brightness, wide viewing angle)TFT colorSTN colorSTN monochrome

Power supply specsCodeAD

100 to 240VAC24VDC

Model nameCode1511

11H090501

SpecificationCode908075706050

* For inquiries relating to products which conform to UL, cUL, and CE directives, please contact your local sales office.

GT15GT11Handy GOT

Common to both GT15 and GT11

15"12.1"Common to 15", 12.1", 10.4", and 8.4".10.4"8.4"5.7"

Version upgrade

Version upgrade

Version upgrade Version upgrade

Version upgrade

Version upgrade

*1: The unit maybe unusable depending on the connection destination. For details, see the "Connection configuration" section from page 32 and relevant manuals.

*2: All units other than MELSECNET/10 and CC-Link communication units conform to CE / UL/ cUL.

Page 29: Mitsubishi GOT1000

Q bus connection

cable

(For QCPU (Q mode))

Bus extension connector box

A bus connection

cable

(For QnA/ACPU/

motion controller

(A series))

Bus connector conversion box

Buffer circuit cable

RS-422 cable

RS-232 cable

External

connection cable

FA device

connection

relay cable

USB cable

QCPU extension cable

Inter-GOT connection cable

QCPU long-distance

connection cable

Inter-GOT long-distance

connection cable

Large CPU extension cable

Small CPU extension cable

Small CPU extension cable

Small CPU long-distance

connection cable

Inter-GOT connection cable

Inter-GOT long-distance

connection cable

A0J2HCPU connection cable

QnA/A/FXCPU direct

connection cable

Computer link connection cable

FXCPU direct connection cable

FX communication function

extension board connection

cable

QCPU direct connection cable

Data transmission cable

FX communication function

extension board connection

cable

FX communication function

adaptor connection cable

Data transmission cable

FX communication function

adaptor connection cable

Data transmission cable

FA device, power supply,

operation switch

connection cable

RS-422, power supply,

operation switch

connection cable

RS-232, power supply,

operation switch connection cable

Data transmission cable

0.6m

1.2m

3m

5m

10m

15m

20m

25m

30m

35m

1.2m

3m

5m

0.6m

1.2m

3m

5m

1.2m

2.5m

1.2m

2.5m

0.7m

1.2m

3m

5m

0.45m

0.7m

3m

5m

10.6m

20.6m

30.6m

0.7m

1.2m

3m

5m

10m

20m

30m

1m

0.5m

3m

10m

20m

30m

1m

3m

10m

20m

30m

3m

3m

3m

3m

6m

10m

3m

6m

10m

1.5m

1.5m

1.5m

2m

For connection between QCPU and GOT

For connection between GOT and GOT

For long-distance (13.2m or more) connection

between QCPU and GOT (A9GT-QCNB required)

For connection between GOT and GOT

Used for QCPU long-distance (13.2m or more) bus connection

For connection between QnA/ACPU/motion controller CPU

(A series/extension base) and GOT

For connection between QnA/ACPU/motion controller CPU

(A series/extension base) and A7GT-CNB

For connection between motion controller CPU

(A series/main base) and GOT

For connection between motion controller CPU

(A series/main base) and A7GT-CNB

For connection between QnAS/AnSCPU/motion controller CPU

(A series) and GOT

For connection between QnAS/AnSCPU and GOT

For connection between QnAS/AnSCPU/motion controller CPU

(A series) and A7GT-CNB

For connection between QnAS/AnSCPU and A7GT-CNB

For connection between QnAS/AnSCPU/motion controller CPU (A series)

and GOT (Long distance)

For connection between A7GT-CNB and GOT (Long distance)

*Combination of GT15-EXCNB and GT15-C BS

For connection between GOT and GOT

For connection between GOT and GOT

For connection between A0J2HCPU power supply unit (A0J2-PW) and GOT

Used for QnA/ACPU long-distance bus connection

Can be used with GT15-C BS as GT15-C EXSS-1

For connection between QnA/ACPU/motion controller CPU

(A series)/FXCPU (D-sub 9-pin connector) and GOT.

For connection between FA-CNV CBL and GOT.

For connection between serial communication unit and GOT

For connection between FXCPU (MINI-DIN 8-pin connector)

and GOT.

For connection between FXCPU communication function extension

board and GOT.

For connection between QCPU and GOT *Excluding Handy GOT

For connection between personal computer (drawing software)

(D-sub 9-pin: female) and GOT (MINI-DIN 6-pin: female) *Handy GOT only

For connection between FXCPU communication function extension board (D-sub 9-pin

connector) and GOT.

For connection between FXCPU communication function adaptor

(D-sub 9-pin connector) and GOT.

For connection between personal computer (drawing software) (D-sub 9-pin: female) and

GOT (D-sub 9-pin: female)

For connection between FXCPU communication function adaptor (D-sub

25-pin connector) and GOT.

For connection between personal computer (drawing software)

(D-sub 25-pin: male) and GOT (D-sub 9-pin: female)

For connection between FA device connection relay cable and GOT

For connection between FA device, power supply, operation switch and GOT

For connection between FXCPU and GOT

For connection between power supply, operation switch and GOT

For connection between A/QnACPU and GOT

For connection between power supply, operation switch and GOT

For connection between QCPU and GOT

For connection between power supply, operation switch and GOT

For connection between personal computer (drawing software) (USB) and GOT (USB Mini-B)

Product name Model name Cable length

Cable length

3rd partyproducts*1

3rd partyproducts*1Specification

*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office.

*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office.

*2: RS-422 conversion unit (GT15-RS2T4-9P) is required.

CablesApplicable model

RS-232 cable

RS-422 cable

Cable for OMRON PLC

Cable for KEYENCE PLC

Cable for SHARP PLCCable for TOSHIBA PLCCable for Hitachi Industrial Equipment Systems PLC

Cable for Matsushita Electric Works PLC

Cable for Yaskawa Electric PLC

Cable for Yokogawa Electric PLCCable for Allen-Bradley PLC

SIEMENS PLC

Cable for OMRON PLC

Cable for KEYENCE PLC

Cable for SHARP PLC

Cable for TOSHIBA PLC

Cable for Hitachi Industrial Equipment Systems PLC

Cable for Yaskawa Electric PLC

Cable for Yokogawa Electric PLC

GT09-C30R20101-9P

GT09-C30R20102-25SGT09-C30R20103-25PGT09-C30R21101-6PGT09-C30R21102-9SGT09-C30R21103-3TGT09-C30R20601-15PGT09-C30R20602-15PGT09-C30R20501-9PGT09-C30R20502-15P

GT09-C30R20401-15P

GT09-C30R20402-15PGT09-C30R20901-25P

GT09-C30R20902-9P

GT09-C30R20903-9PGT09-C30R20904-3CGT09-C30R20201-9PGT09-C30R20202-15PGT09-C30R20203-9PGT09-C30R20204-14PGT09-C30R20205-25P

GT09-C30R20301-9PGT09-C30R20302-9PGT09-C30R20701-9SGT09-C30R20702-25P

GT09-C30R20801-9S

GT09-C30R40101-9PGT09-C100R40101-9PGT09-C200R40101-9PGT09-C300R40101-9PGT09-C30R40102-9PGT09-C100R40102-9PGT09-C200R40102-9PGT09-C300R40102-9PGT09-C30R41101-5TGT09-C100R41101-5TGT09-C200R41101-5TGT09-C300R41101-5TGT09-C30R40601-15PGT09-C100R40601-15PGT09-C200R40601-15PGT09-C300R40601-15PGT09-C30R40602-15PGT09-C100R40602-15PGT09-C200R40602-15PGT09-C300R40602-15PGT09-C30R40603-6TGT09-C100R40603-6TGT09-C200R40603-6TGT09-C300R40603-6TGT09-C30R40501-15PGT09-C100R40501-15PGT09-C200R40501-15PGT09-C300R40501-15PGT09-C30R40502-6CGT09-C100R40502-6CGT09-C200R40502-6CGT09-C300R40502-6CGT09-C30R40503-15PGT09-C100R40503-15PGT09-C200R40503-15PGT09-C300R40503-15PGT09-C30R40401-7TGT09-C100R40401-7TGT09-C200R40401-7TGT09-C300R40401-7TGT09-C30R40201-9PGT09-C100R40201-9PGT09-C200R40201-9PGT09-C300R40201-9PGT09-C30R40202-14PGT09-C100R40202-14PGT09-C200R40202-14PGT09-C300R40202-14PGT09-C30R40301-6TGT09-C100R40301-6TGT09-C200R40301-6TGT09-C300R40301-6TGT09-C30R40302-6TGT09-C100R40302-6TGT09-C200R40302-6TGT09-C300R40302-6T

3m

3m3m3m3m3m3m3m3m3m

3m

3m3m

3m

3m3m3m3m3m3m3m

3m3m3m3m

3m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

3m10m20m30m

PLC CPU: CQM1/CQM1H/CS1/CJ1/CV500/CV1000/CV2000/CVM1Serial communication unit: CS1W-SCU21Communication board: C200HW-COM2/COM05/COM06Serial communication board: CQM1-SCB41/CS1W-SCB41/CS1W-SCB21Connection cable: CQM1-CIF01Base mounted type upper link unit: C500H-LK201-V1PLC CPU: KV-700/1000Communication unit: KV-L20/L20R port1Communication unit: KV-L20/L20R port2PLC CPU: JW-22CU/70CUH/100CUH/100CUPLC CPU: JW-32CUH/33CUHPLC CPU: T2EPLC CPU: T2NPLC CPU: H-4010/H series board type/EH-150 seriesIntelligent serial port module: COMM-H/COMM-2HPLC CPU: H-4010/EH-150 seriesRS-422/232 conversion adaptor: AFP8550PLC CPU: FP2/FP2SH/FP10(S)/FP10SH/FP-MComputer communication unit: AFP2462/AFP3462/AFP5462PLC CPU: FP1-C24C/C40CPLC CPU: FP1-C16CT/C32CTPLC CPU: PROGIC-8/MP-920/MP-930PLC CPU: PROGIC-8PLC CPU: CP-9300MS MEMOBUS module: CP-217IFPLC CPU: MP-940MEMOBUS module: CP-217IF Yokogawa Electric personal computer module: LC01-0N/LC02-0NCPU port/D-sub 9-pin conversion cable: KM10-0CPersonal computer module: F3LC11-1N/F3LC11-1F/F3LC12-1F/F3LC11-2NPLC CPU: SL500 series Converter: 1761-NET-AICAdaptor: 1770-KF3

HMI adaptor

PLC CPU: CV500/CV1000/CV2000/CVM1Communication board: C200HW-COM03/COM06Serial communication board: CQM1-SCB41/CS1W-SCB41

Base mounted type upper link unit: C200H-LK202-V1/C500H-LK201-V1

Communication unit: KV-L20/L20R port2

PLC CPU: JW-22CU/70CUH/100CUH/100CU

PLC CPU: JW-32CUH/33CUH

Link unit: JW-21CM/10CM/ZW-10CM

PLC CPU: T2/T3/T3H/model3000(S3)

PLC CPU: T2E

PLC CPU: T2N

Intelligent serial port module: COMM-H/COMM-2H

MEMOBUS module: JAMSC-120NOM27100/JAMSC-IF612

PLC CPU: MP940

Personal computer link module: F3LC11-2N

Personal computer link module: LC01-0N/LC02-0N

Product name Model name GOT connection destination

Cables for other brand PLC

L i s t o f p r o d u c t s

58 59

List o

f pro

du

cts

GT15 GT11 Handy GOTApplicable model

GT15 GT11 Handy GOT

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

GT15-QC06B

GT15-QC12B

GT15-QC30B

GT15-QC50B

GT15-QC100B

GT15-QC150BS

GT15-QC200BS

GT15-QC250BS

GT15-QC300BS

GT15-QC350BS

A9GT-QCNB

GT15-C12NB

GT15-C30NB

GT15-C50NB

GT15-AC06B

GT15-AC12B

GT15-AC30B

GT15-AC50B

GT15-A370C12B-S1

GT15-A370C25B-S1

GT15-A370C12B

GT15-A370C25B

GT15-A1SC07B

GT15-A1SC12B

GT15-A1SC30B

GT15-A1SC50B

GT15-A1SC05NB

GT15-A1SC07NB

GT15-A1SC30NB

GT15-A1SC50NB

GT15-C100EXSS-1

GT15-C200EXSS-1

GT15-C300EXSS-1

GT15-C07BS

GT15-C12BS

GT15-C30BS

GT15-C50BS

GT15-C100BS

GT15-C200BS

GT15-C300BS

GT15-J2C10B

A7GT-CNB

GT15-EXCNB

GT01-C30R4-25P

GT01-C100R4-25P

GT01-C200R4-25P

GT01-C300R4-25P

GT01-C10R4-8P

GT01-C30R4-8P

GT01-C100R4-8P

GT01-C200R4-8P

GT01-C300R4-8P

GT01-C30R2-6P

GT01-C30R2-9S

GT01-C30R2-25P

GT11H-C30-37P

GT11H-C60-37P

GT11H-C100-37P

GT11H-C30

GT11H-C60

GT11H-C100

GT11H-C15R4-8P

GT11H-C15R4-25P

GT11H-C15R2-6P

GT09-C20USB-5P

NEW

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

coming soon

Page 30: Mitsubishi GOT1000

60 61

MemoMemo

Page 31: Mitsubishi GOT1000

Mitsubishi Graphic Operation Terminal

• To use the products given in this catalog properly, always read the "manuals" before starting to use them.

• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.

• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

For safe useThis catalog explains the typical features and functions of the GOTs and does not provide restrictions and other information on usage and module combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the user's manuals. When using the products, always read the user's manuals of the products.Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.

Precautions for Choosing the Products

When exported from Japan, this manual does not require application to the Ministry of International Trade and Industry for service transaction permission.

ELECTRIC CORPORATION HEAD OFFICE: 1-8-12,OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN

NAGOYA WORKS: 1-14,YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN

Country/Region Sales office Tel/Fax

U.S.A Mitsubishi Electric Automation Inc. Tel : +1-847-478-2100 500 Corporate Woods Parkway Vernon Hills, IL 60061 Fax : +1-847-478-2396

Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-5908-8331 Rua Correia Dias,184, Edificio Paraiso Trade Center-8 andar Paraiso, Fax : +55-11-5574-5296 Sao Paulo, SP Brazil

Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0 Gothaer Strasse 8 D-40880 Ratingen, GERMANY Fax : +49-2102-486-7170

U.K Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-276100 Travellers Lane, Hatfield, Herts., AL10 8XB,UK Fax : +44-1707-278695

Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531 Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Fax : +39-039-6053312 Via Paracelso 12, 20041 Agrate B., Milano, Italy

Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131 Carretera de Rubi 76-80 Fax : +34-93-589-2948 08190 Sant Cugat del Valles, Barcelona, Spain

France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568 225 Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5685

South Africa Circuit Breaker Industries LTD Tel : +27-11-928-2000 Private Bag 2016, 1600 Isando, Tripswitch Drive, Elandsfontein Gauteng, South Africa Fax : +27-11-392-2354

Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd. Tel : +852-2887-8870 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Fax : +852-2887-7984

China Mitsubishi Electric Automation (Shanghai) Ltd. Tel : +86-21-6475-3228 1-3/F., Block5, 103 Cao Bao Road, Shanghai 200233, China Fax : +86-21-6474-6996

Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Fax : +886-2-2299-2509

Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9552 Dong seo Game Channel Bldg. 2F 660-11, Deungchon-dong, Kangseo-ku, Fax : +82-2-3664-8372 Seoul 157-030, Korea

Singapore Mitsubishi Electric Asia Pte, Ltd. Tel : +65-6470-2460 307 Alexandra Road #05-01/02, Fax : +65-6476-7439 Mitsubishi Electric Bulding Singapore 159943

Thailand F.A. Tech Co., Ltd. Tel : +66-2-682-6522 896/19, 20, 21, 22, S. V. City Building, Office Tower 1, Floor Fax : +66-2-682-6020 12 Rama III Rd, Bangpongpang, Yannawa, Bangkok 10120

Indonesia Indonesia P.T. Autoteknindo SUMBER MAKMUR Tel : +62-21-663-0833 Muara Karang Selatan Block A/Utara No.1 Kav. Fax : +62-21-663-0832 No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440

India Messung Systems Pvt, Ltd. Tel : +91-20-2712-3130 Electronic Sadan NO:111 Unit No15, M.I.D.C Bhosari, Pune-411026, India Fax : +91-20-2712-8180

Australia Mitsubishi Electric Australia Pty. Ltd. Tel : +61-2-9684-7777 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245

New publication, effective November, 2005Specifications subject to change without notice.L(NA)08054E-B 0511(MDOC)