Enhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems.

Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Embed Size (px)

Citation preview

Page 1: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Enhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems.

Page 2: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

The Mitsubishi Electric Story.Mitsubishi Electric have a proud history in the manufacturing and supply of leading edge electrical and electronic equipment for both domestic and commercial use. Our efforts to make indoor life more comfortable began in 1921, with the introduction of our first electric fan which became an instant hit. Some 10 years later we began to manufacture coolers, which were just as popular.

Since then our understanding that technology is the driving factor of change in our lives has seen us become a world leader in energy efficient air conditioning systems. However our development of breakthrough technologies and products is not just restricted to heating and cooling.

Since 1980 to the present day the pace at which Mitsubishi Electric has introduced and refined products that benefit society, industry and individuals, has been nothing less than astonishing.

These technologies include the world’s first large scale LED Screen for sports arenas, the world’s largest CRT television screen for the consumer market, the world’s first spiral escalator, the world’s fastest elevators, the antenna technology behind the world’s first in-flight internet service, solar cell technology and much more.Today Mitsubishi Electric is a global giant with operations in over 35 countries, with more than 97,000 employees.

Our commitment to quality service, research and development has helped us gain a leading position in today’s marketplace in a wide variety of areas including heating, cooling and air conditioning. Mitsubishi Electric’s ‘today technology’ provides climate controlled comfort wherever you live, work and relax.

Whether it’s consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple to use, reliable and above all, energy efficient.

Our commitment to quality, service, research and development has helped us gain a leading position in today’s marketplace.

Page 3: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Indoor Fan Coil UnitDelivers the conditioned air to the ductwork.

Outdoor UnitQuietly delivers refrigerant to the indoor unit.

Air DiffuserDiffusers are available in many designs to suit the decor of your home.

System ControllerLocated conveniently within the home generally near the return air grille.

DuctworkDelivers the conditioned air throughout the rooms of your home.

Return Air Grille and FilterFilters the air as it returns it back to the indoor unit.

Round DiffuserLinear Diffuser

4 Way Diffuser

To enhance your living environment has to be the ultimate in comfort.With Mitsubishi Electric Ducted Inverter Systems, climate control is at the touch of a button. Warm even heat during Winter and clean cool air during Summer. Our Ducted Systems are ideal for multiple room applications and can incorporate zone selection if required.

The Outdoor Inverter Unit that provides the power, is positioned outside your home, while the Indoor Fan Coil Unit is positioned out of sight in either the ceiling void, or under the floor. Cool or warm air is then ducted quietly into each room through visually appealing Air Diffusers positioned in the ceiling, wall or floor. Warm or cool air is then filtered and returned to the Indoor Fan Coil Unit through the Return Air Grille.

The system is easily operated via a wall mounted LCD Control Panel.

Mitsubishi Electric’s Ducted Inverter Technology gives you the edge.Mitsubishi Electric’s Advanced Technology Inverter Systems are more economical and efficient than conventional systems.

Conventional non-inverter systems run at a fixed speed. To maintain a set temperature the compressor switches on/off so room temperatures continually fluctuate, falling, rising and falling again.

To overcome this problem Mitsubishi Electric’s advanced inverter technology gently increases or decreases power to suit the prevailing conditions reaching the desired temperature quicker, more efficiently without severe temperature fluctuations.

The resulting reduction in electricity consumption by our energy saving technology not only saves you money but also reduces your carbon footprint on the environment.

Mitsubishi Electric’s Outdoor Inverter units have been aesthetically designed to minimise their visual impact on your environment.

Each contains a number of innovative features that makes them quieter, more energy efficient and reliable, placing them at the cutting edge in the industry.

Conventional air conditioner:Unstable temperature control

Inverter operation:Uniform temperature control

Set temperature

Temperature fluctuation

Compressor operation

Compressor operationON OFF ON OFF

Too cold

Too hot

Time

Time

Uniform temperature control

Set temperature

Page 4: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Conditions of trial calculation ( according to Japan Refrigerant Association )

Place

Operating time

Operatingperiod

Settemperature

Office in Tokyo (Japan)

8AM to 8PM (12 hours/day) &6 days/week

Cooling: April 16–November 8 Heating: December 14–March 23

Before replacement:

Installed 8 years ago

Model name PLH-3GKHB/PUH-3YKA

After replacement:

Power Inverter

Model name PLA-RP71AA/PUHZ-RP71VHA

70%reduction

Power Inverter Non-Inverter (R407C)

COP

Outdoor Unit

3.5

3.0

3HP 4HP 5HP 6HP

2.81

Average

33%increase

17%UP

3.30

26%UP

3.21

26%UP

2.402.61

2.55

2.25

3.60

60%UP

Reducing Energy Consumption.Cost performance comparison Inverter model vs. non-Inverter model:Thanks to the new Inverter System, a large reduction in power consumption is now possible.

This results in one of the highest COP* (Co-efficient of Performance) ratings in the industry, helping to lower overall running costs and provide greater savings.

Case Study 1– Power Consumption Based on our calculations on the operating conditions shown below, the new Inverter System can reduce power consumption by up to 70% compared to an old model installed 8 years ago.

Case Study 2 – COP* Comparison of COP between non-Inverter and Power Inverter (4 way cassette type) models.

Quiet OperationImprovements in the design of our fan blades combined with a new grille shape has seen us become No 1 in the industry.

The outdoor unit is even quieter when the outside temperatures drops, as it automatically switches to low noise mode which reduces it’s operating noise by a further 3dB.

DC Fan MotorA highly efficient DC Motor drives the fan of the outdoor unit, offering up to 60% greater efficiency than the equivalent AC Motor.

Peace of MindAll Mitsubishi Electric air conditioners used in residential applications are covered by a full 5 year parts and labour warranty.

Mitsubishi Electric air conditioners have been designed and built to deliver optimum performance year in year out.

* COP is a performance and efficiency rating similar to the Star Energy Rating System. The higher the COP, the more efficient the system.

Noise level

Train interior

Quiet passenger car interior (40km/h) Library interior

Sound of rustling leaves

Human hearing limits

(Extremely quiet)

10dB40dB60dB80dB

The compact configuration provides larger airflow with low noise.

OUTDOOR UNIT NOISE COMPARISON

*AT OUTDOOR TEMPERATURE OF 25ºC

DAY

50dB(in cooling mode)

DAY

47dB(in cooling mode)

Low-Noisemode

Suppressing to

about 1/2 audible sound compared to daytime

Page 5: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Higher performance, lower power consumption and longer life. When it comes to comfort, efficiency and durability, Mitsubishi Electric has a distinct advantage over the opposition, we call it MEQ – Mitsubishi Electric Quality. Simply put it is a superior standard that we apply to our own business. While other systems may meet stringent industry standards, Mitsubishi Electric continually strives to exceed them. MEQ delivers air conditioning systems at the leading edge of technology that operate efficiently in extreme weather conditions, year in, year out.

MEQ Gives Us 3 Important Advantages: Comfort

We have created products that are designed to provide you with exceptional comfort in your surroundings, in all weather conditions.

Efficiency

We strive for the perfect balance of performance, reliability, low power consumption and a long operational life span for all our products. The result is an air conditioning range that is rated amongst the best in the industry in terms of design, quality and energy efficiency.

Durability

We subject the indoor and outdoor units of all our systems to rigorous durability testing, which includes harsher temperature extremes than are likely to be found anywhere in the world. This allows us to produce higher quality products that protect your investment through years of reliable service.

Page 6: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Compact Inverter.The Advanced Technology in Mitsubishi Electric’s Compact Inverter makes it the perfect solution for today’s diversified Residential and Commercial requirements. For homes, or small to medium size offices, our Compact Inverter Ducted System gives you cost effective climate control for both heating and cooling. Technological advances have increased output and efficiency, allowing you to reach and maintain your chosen temperature faster, without fluctuations, while using less energy. The Compact Inverter is smaller and lighter, making handling and installation easier which gives you more flexibility in your choice of location.

Quiet OperationThe Compact Inverter operates at noise levels that are at the leading edge of Industry Standards.

Longer Maximum Piping LengthThe new technology has also made it possible to pipe refrigerant up to 70 metres from the Inverter to the concealed Indoor Fan Coil Unit, giving you more choice and versatility in the layout of your Ducted System and positioning your Outdoor Unit.

Flexibility in Layout Planning is further enhanced by the integration of the Compact Inverter or Power Inverter outdoor units and our range of Concealed Indoor Units.

Concealed Indoor UnitMitsubishi Electric’s range of Concealed Indoor Units are versatile and easy to install even where roof or under floor space is limited.

High Output Fan CapabilityEven when the ductwork is very long, the volume of airflow remains consistent due to the high static pressure available from the fan coil unit’s multiple speed fan motor.

Computerised DehumidificationThis feature allows you to reduce the humidity inside your home keeping you comfortable in all seasons.

Power Inverter.Ideal for larger homes or medium to large offices, the Mitsubishi Electric Power Inverter boasts all of the technological advances of the Compact Inverter with a number of design features that further reduce power consumption and make it ideally suited to commercial applications.

Ultra Quiet OperationImprovements to the design of the dual fan blades and a new grille shape deliver operating noise levels that are the best in the industry. A Low Noise Priority function is also available, where the noise of the outdoor unit can be reduced via a switch or time clock.

Longer Maximum Piping LengthThe Power Inverter can pipe refrigerant up to 75 metres to the concealed ceiling unit, further adding to it’s versatility and efficiency in getting airflow to where it is most effective.

Multi System UseThe Mitsubishi Electric Power Inverter can be connected to a number of concealed indoor units that can be centrally controlled by one remote controller.

100mm from wall 500mm from unit

100mm from wall 500mm from unit

Twin Triple

Compact Inverter

PUHZ-BP140VHA 2 x PEA-RP71

PUHZ-BP200VHA 2 x PEA-RP100EA-2

PUHZ-BP250VHA 2 x PEA-RP125

PUHZ-BP250VHA 3 x PEA-RP71

Power Inverter

PUHZ-RP140VHA2 2 x PEA-RP71

PUHZ-RP140YHA2 2 x PEA-RP71

Model Size 71 100 125 140 200 250

Compact Inverter SUZ PUHZ-BP

Single Phase • • • •

Three Phase • •

Power Inverter PUHZ-RP

Single Phase • • • •

Three Phase • • •

Easier Installation Work Thanks to Compact and Light Weight Design

The newly developed scroll com-pressor is equipped with a “Frame Compliance Mechanism” that al-lows movement in the axial direc-tion of the frame supporting the cradle scroll. This greatly reduces both leaking and friction loss, en-suring very high efficiency through-out the speed range.

The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets and reluctance torque results in more efficient operation.

This produces the most efficient waveform in response to varying compressor motor rpm. By improving operat-ing efficiency from low to high speeds, annual electricity costs are reduced.

Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and out-door temperature, this technology is tailored to the char-acteristics of the new refrigerant to enhance operating efficiency.

A high-efficiency DC motor drives the fan of the outdoor unit. It offers up to 60% greater efficiency than an equivalent AC motor.

Our New Inverter features Energy Saving, Compact Design, Light Weight,and Basic Performances as well.

Advanced technology for High Efficiency

Numerous Leading-edge Technologies Assure High Efficiency

The inverter has been made com-pact by insert-moulding the cir-cuit pattern in synthetic resin.To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters.

S series outdoor unit can be connected not only with SLZ and SEZ but also some P series indoor units. Greater inverter line up satisfies your various requirement.

The silent operation of the outdoor unit Model BP100 has attained down to 50dB (cooling). Further 3dB can be reduced under the Silent Operation Mode.

Standard Inverter

Silent Outdoor Unit

Heating Operation Possible Even at 15°C Outside Temperature

Another possibility! Compact S series outdoor unit can now be connected to P series indoor unit as well.

A Product Line of 19 Models in 5 Types Responds toYour Versatile Needs.

To meet your interior or space designing, optimum indoor units can be selected from 5 types. A combination with different type indoor units in two or three rooms besides 1:1 combination can be constituted various applications.

The outdoor unit model BP100 counts for 943mm only for the height and 66kg for the mass. A significant weight reduction of 55kg has been attained compared to the Power Inverter. The burdening of installation/transporta-tion work can be lightened by the compact design and light weight. BP200/250 became compact as well!!

3dB reduction50dB 47dB

Suppressing to

about 1/2 audible sound (compared to daytime)

Piping Length for Easier Installation

Refrigerant piping can be extended up to 50m or 70m by charging refrigerant additionally.

NEW

SUZ-KA25SUZ-KA35SUZ-KA50SUZ-KA60SUZ-KA71

5.0kW

6.0kW

7.1kW

10.0kW

12.5kW

14.0kW*50/60/71 models are for Twin/Triple use.

R22Fixed Speed New Inverter66kgPower Inverter New Inverter121kg

131kgTop flow Side flow198kgBP100

BP125/140BP200/250

20m20m30m

50m50m70m

94kg 66kg

2007_SLIM_Aus 07.8.8 1:44 PM ページ 7

Concealed Indoor Unit

PEA - RP100EA2PEA - RP125EA

Max Height Difference Max Piping Length

Compact Inverter

SUZ-KA71 15 30

PUHZ-BP100,125,140VHA 30 50

PUHZ-BP200/250VHA 30 70

Power Inverter

PUHZ-RP71VHA2 30 50

PUHZ-RP100,125,140VHA2 30 75

PUHZ-RP100,125,140YHA2 30 75

( )( ) ( )

Suppressing to

about 1/2 audible sound compared to daytime

Page 7: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Guaranteed Operating Range

SUZ-KA

10°C

24°C

15°C

15°C

24°C

10°C

21°C

20°C

25/35 50/60/71 all

46°C 43°C 46°C

PUHZ-RP/BP

5°C ( 15°C )1

2

With the optional air outlet guide, the operation at 15°C outdoor temperature is possible.

Complies with AS/NZS 3823.2:2005 Clause 3.4 (Amdt1).

1

3

11°C for PUHZ-RP71. 2

Compact Inverter – Outdoor units

Capacity Rated kWCapacity (min-max) kW

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingkW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Outdoor unit

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Indoor unitPower supply

SUZ-KA71VA

Single phase, 50Hz, 220-240V

Indoor unit

Outdoor unitFunction

PUHZ-BP200YHAPUHZ-BP100VHA PUHZ-BP250YHA

1067-1333125

367-450 450-567 567-700

52-55 54-58 53-55428785690

4281,055690

4281,255690

Power supply

818

Single phase, 50Hz, 220-240V

55

80

PUHZ-BP200YHA PUHZ-BP250YHAExternal finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1

100053

1.3

20

50475470

667

30

68943950

330+30

18.24/15.64

2053

850840330

52495572

Indoor unit

80

15.26/11.68

54-58 51-55

50

125

Discharge thermo, HP switch

3225

2 3.4

FunctionIndoor unit

PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2External finishPower supply

Munsell 3.0Y 7.8/1.1V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V

PUHZ-RP71VHA2 PUHZ-RP100V/YHA2

Single phase, 50Hz, 220-240V367-450 450-567 567-700 800-1000

920 1000 11701.6 1.9 2.4 3.9

44 47 49 5147 50 52 54

66 70 72 7448 54 55 56

Power supply

75 121 116 116

50 75Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:168.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20

1350950

330+30

V: 19.65/19.92 Y:6.37/6.46

30 30

1,255 1,415428 428 428 428

52-55

690 690 690 690785 1,055

46 59 72 76

4651,600614

46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 3.222.31 2.34 3.39 3.012.53 2.53 3.01 2.49 3.21

1170545156

84

74

19.46/15.3840

3.9

PUHZ-BP125VHA PUHZ-BP140VHA

5.5

133

1.0/12.01

PUHZ-BP170YHA

126

9.47/9.88

4.7Three phase, 50Hz, 380-415V

5956

2167

330+30

Shell thermo, HP switch70

5977

30

1350950

32

PEA-RP125EA

PUHZ-BP125VHA

PEA-RP140EA2

PUHZ-BP140VHA

(0.9-10.2)(0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5)

PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

51-55

76

4281,415690

800-1000Three phase, 50Hz, 380-415V

800-1000150

47-51

74

4651,600614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EAPEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2

Capacity Rated (min-max) 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0) Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25

Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 5.39 4.07 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50

PUHZ-BP170YHA

Capacity Rated kWCapacity (min-max) kW

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingkW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Outdoor unit

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Indoor unitPower supply

SUZ-KA71VA

Single phase, 50Hz, 220-240V

Indoor unit

Outdoor unitFunction

PUHZ-BP200YHAPUHZ-BP100VHA PUHZ-BP250YHA

1067-1333125

367-450 450-567 567-700

52-55 54-58 53-55428785690

4281,055690

4281,255690

Power supply

818

Single phase, 50Hz, 220-240V

55

80

PUHZ-BP200YHA PUHZ-BP250YHAExternal finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1

100053

1.3

20

50475470

667

30

68943950

330+30

18.24/15.64

2053

850840330

52495572

Indoor unit

80

15.26/11.68

54-58 51-55

50

125

Discharge thermo, HP switch

3225

2 3.4

FunctionIndoor unit

PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2External finishPower supply

Munsell 3.0Y 7.8/1.1V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V

PUHZ-RP71VHA2 PUHZ-RP100V/YHA2

Single phase, 50Hz, 220-240V367-450 450-567 567-700 800-1000

920 1000 11701.6 1.9 2.4 3.9

44 47 49 5147 50 52 54

66 70 72 7448 54 55 56

Power supply

75 121 116 116

50 75Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:168.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20

1350950

330+30

V: 19.65/19.92 Y:6.37/6.46

30 30

1,255 1,415428 428 428 428

52-55

690 690 690 690785 1,055

46 59 72 76

4651,600614

46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 3.222.31 2.34 3.39 3.012.53 2.53 3.01 2.49 3.21

1170545156

84

74

19.46/15.3840

3.9

PUHZ-BP125VHA PUHZ-BP140VHA

5.5

133

1.0/12.01

PUHZ-BP170YHA

126

9.47/9.88

4.7Three phase, 50Hz, 380-415V

5956

2167

330+30

Shell thermo, HP switch70

5977

30

1350950

32

PEA-RP125EA

PUHZ-BP125VHA

PEA-RP140EA2

PUHZ-BP140VHA

(0.9-10.2)(0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5)

PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

51-55

76

4281,415690

800-1000Three phase, 50Hz, 380-415V

800-1000150

47-51

74

4651,600614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EAPEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2

Capacity Rated (min-max) 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0) Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25

Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 5.39 4.07 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50

PUHZ-BP170YHA

Power Inverter – Indoor units

Power Inverter – Outdoor units

Capacity Rated kWCapacity (min-max) kW

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingkW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Outdoor unit

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Indoor unitPower supply

SUZ-KA71VA

Single phase, 50Hz, 220-240V

Indoor unit

Outdoor unitFunction

PUHZ-BP200YHAPUHZ-BP100VHA PUHZ-BP250YHA

1067-1333125

367-450 450-567 567-700

52-55 54-58 53-55428785690

4281,055690

4281,255690

Power supply

818

Single phase, 50Hz, 220-240V

55

80

PUHZ-BP200YHA PUHZ-BP250YHAExternal finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1

100053

1.3

20

50475470

667

30

68943950

330+30

18.24/15.64

2053

850840330

52495572

Indoor unit

80

15.26/11.68

54-58 51-55

50

125

Discharge thermo, HP switch

3225

2 3.4

FunctionIndoor unit

PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2External finishPower supply

Munsell 3.0Y 7.8/1.1V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V

PUHZ-RP71VHA2 PUHZ-RP100V/YHA2

Single phase, 50Hz, 220-240V367-450 450-567 567-700 800-1000

920 1000 11701.6 1.9 2.4 3.9

44 47 49 5147 50 52 54

66 70 72 7448 54 55 56

Power supply

75 121 116 116

50 75Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:168.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20

1350950

330+30

V: 19.65/19.92 Y:6.37/6.46

30 30

1,255 1,415428 428 428 428

52-55

690 690 690 690785 1,055

46 59 72 76

4651,600614

46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 3.222.31 2.34 3.39 3.012.53 2.53 3.01 2.49 3.21

1170545156

84

74

19.46/15.3840

3.9

PUHZ-BP125VHA PUHZ-BP140VHA

5.5

133

1.0/12.01

PUHZ-BP170YHA

126

9.47/9.88

4.7Three phase, 50Hz, 380-415V

5956

2167

330+30

Shell thermo, HP switch70

5977

30

1350950

32

PEA-RP125EA

PUHZ-BP125VHA

PEA-RP140EA2

PUHZ-BP140VHA

(0.9-10.2)(0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5)

PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

51-55

76

4281,415690

800-1000Three phase, 50Hz, 380-415V

800-1000150

47-51

74

4651,600614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EAPEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2

Capacity Rated (min-max) 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0) Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25

Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 5.39 4.07 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50

PUHZ-BP170YHA

Concealed Indoor Units

Capacity Rated kWCapacity (min-max) kW

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingkW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)Weight kg

Outdoor unit

Compressor output kWAirflow L/S

Cooling modeSound pressure level (dB)Silent modeHeating mode

Sound power level dB(A)Height (mm)

Dimensions Width (mm)Depth (mm)

Weight kgChargeless piping length mMax piping length mProtection deviceRated running current AmpsBreaker size Amps

Indoor unitPower supply

SUZ-KA71VA

Single phase, 50Hz, 220-240V

Indoor unit

Outdoor unitFunction

PUHZ-BP200YHAPUHZ-BP100VHA PUHZ-BP250YHA

1067-1333125

367-450 450-567 567-700

52-55 54-58 53-55428785690

4281,055690

4281,255690

Power supply

818

Single phase, 50Hz, 220-240V

55

80

PUHZ-BP200YHA PUHZ-BP250YHAExternal finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1

100053

1.3

20

50475470

667

30

68943950

330+30

18.24/15.64

2053

850840330

52495572

Indoor unit

80

15.26/11.68

54-58 51-55

50

125

Discharge thermo, HP switch

3225

2 3.4

FunctionIndoor unit

PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2External finishPower supply

Munsell 3.0Y 7.8/1.1V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V

PUHZ-RP71VHA2 PUHZ-RP100V/YHA2

Single phase, 50Hz, 220-240V367-450 450-567 567-700 800-1000

920 1000 11701.6 1.9 2.4 3.9

44 47 49 5147 50 52 54

66 70 72 7448 54 55 56

Power supply

75 121 116 116

50 75Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:168.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20

1350950

330+30

V: 19.65/19.92 Y:6.37/6.46

30 30

1,255 1,415428 428 428 428

52-55

690 690 690 690785 1,055

46 59 72 76

4651,600614

46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 3.222.31 2.34 3.39 3.012.53 2.53 3.01 2.49 3.21

1170545156

84

74

19.46/15.3840

3.9

PUHZ-BP125VHA PUHZ-BP140VHA

5.5

133

1.0/12.01

PUHZ-BP170YHA

126

9.47/9.88

4.7Three phase, 50Hz, 380-415V

5956

2167

330+30

Shell thermo, HP switch70

5977

30

1350950

32

PEA-RP125EA

PUHZ-BP125VHA

PEA-RP140EA2

PUHZ-BP140VHA

(0.9-10.2)(0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5)

PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2PEA-RP100EA2PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

51-55

76

4281,415690

800-1000Three phase, 50Hz, 380-415V

800-1000150

47-51

74

4651,600614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EAPEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2

Capacity Rated (min-max) 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0) Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25

Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 5.39 4.07 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50

PUHZ-BP170YHA

Page 8: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Concealed Bulkhead. Ideal for apartments or offices where ceiling access is not available for ducting, the ceiling concealed model compresses installation space to just 270 mm in height with the KA series and an even smaller 200mm when using the new KD series. The KD series offers a number of improvements on the KA series including higher static pressure (50Pa) that allows it to be ducted to a limited number of outlets and the choice of hard wired control panel (VA) or infra red remote control (VAL).

Whisper Quiet Operation When operating at full capacity the Bulkhead Unit generates just 28dB of sound, so other than feeling the benefit of the even temperature that it delivers, you would hardly know that it is operating.

SEZ-KA35/50/60/71VA

Noise level

Train interior

Quiet passenger car interior (40km/h) Library interior

Sound of rustling leaves

Human hearing limits

(Extremely quiet)

10dB40dB60dB80dB

SPECIFICA TIONS: BULKHEAD INVERTER TYPE

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingCapacity (min-max) kW 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4Input kW 1.06 1.1 1.78 1.84 1.96 2.45 2.46 2.36

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)W eight kg

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling HeatingCapacity (min-max) kW 0.9 -3.2 0.9 -4.5 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4Input kW 0.778 0.83 1.09 1.108 1.78 1.87 1.89 2.05 2.53 2.37

Airflow (Lo-Med-Hi) L/S

Ext static pressure Pa

Sound pressure level dB(A)

(Low-Mid-High)

Height (mm)

Dimensions Width (mm)

Depth (mm)

W eight kg

Compressor output kWAirflow L/SSound pressure level Cooling mode

Heating modeSound power level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)W eight kgChargeless piping length mMax piping length mBreaker size Amps

SUZ-KA61VA SUZ-KA71VAFunction

Outdoor unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA

35

SEZ-KD25VA SEZ-KD35VA SEZ-KD50VA SEZ-KD60VA SEZ-KD71VA

33.5

2701,100700

Single phase, 50Hz, 220-240V200-333

30-35 31-39

Picture

537

58

4861

3733

550

23 27

0.65 1.3

800285

SUZ-KA35VA SUZ-KA50VAMunsell 3Y 7.8/1.1

568/534

Single phase, 50Hz, 220-240V

4659

SEZ-KD60VA/VAL SEZ-KD71VA/VAL

SUZ-KA61VA SUZ-KA71VA

Single phase, 50Hz, 220-240V

30-34-37

200

1,100

700

5-15-35-50

55146

0.55818

47

0.85

53

Power supplyExternal finishOutdoor unit SUZ-KA25VA

SEZ-KA71VA

Standard: 30, Max: 5032-43

SEZ-KA35VA SEZ-KA50VA SEZ-KA60VA

167-217 200-283

SEZ-KA71VASUZ-KA71VA

SEZ-KA35VA SEZ-KA50VASUZ-KA35VA SUZ-KA50VA

SEZ-KA60VASUZ-KA61VA

Power supply

Indoor unitOutdoor unit

Function

SEZ-KD25VA/VAL SEZ-KD35VA/VAL SEZ-KD50VA/VAL

Power supply

92-1 16-150 116-150-183 166-208-250 200-250-300 200-266-333

23-26-30 30-34-38 30-35-4023-28-33

200

700

700

200

900

700

18 21

2010

55

3020

68850840330

EER Rated COP

EER Rated COP

3.33 3.65 2.76 3.21 2.76 2.77 2.89 3.38

Indoor unit*1

Indoor unit

Indoor unit*1

3.12 3.47 3.06 3.43 2.72 3.07 2.81 3.25 2.77 3.29

Specification Chart Concealed Bulkhead

Specification Chart Outdoor Bulkhead Units

SPECIFICA TIONS: BULKHEAD INVERTER TYPE

Cooling Heating Cooling Heating Cooling Heating Cooling HeatingCapacity (min-max) kW 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4Input kW 1.06 1.1 1.78 1.84 1.96 2.45 2.46 2.36

Airflow (Lo-Hi) L/SExt static pressure PaSound pressure level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)W eight kg

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling HeatingCapacity (min-max) kW 0.9 -3.2 0.9 -4.5 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4Input kW 0.778 0.83 1.09 1.108 1.78 1.87 1.89 2.05 2.53 2.37

Airflow (Lo-Med-Hi) L/S

Ext static pressure Pa

Sound pressure level dB(A)

(Low-Mid-High)

Height (mm)

Dimensions Width (mm)

Depth (mm)

W eight kg

Compressor output kWAirflow L/SSound pressure level Cooling mode

Heating modeSound power level dB(A)

Height (mm)Dimensions Width (mm)

Depth (mm)W eight kgChargeless piping length mMax piping length mBreaker size Amps

SUZ-KA61VA SUZ-KA71VAFunction

Outdoor unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA

35

SEZ-KD25VA SEZ-KD35VA SEZ-KD50VA SEZ-KD60VA SEZ-KD71VA

33.5

2701,100700

Single phase, 50Hz, 220-240V200-333

30-35 31-39

Picture

537

58

4861

3733

550

23 27

0.65 1.3

800285

SUZ-KA35VA SUZ-KA50VAMunsell 3Y 7.8/1.1

568/534

Single phase, 50Hz, 220-240V

4659

SEZ-KD60VA/VAL SEZ-KD71VA/VAL

SUZ-KA61VA SUZ-KA71VA

Single phase, 50Hz, 220-240V

30-34-37

200

1,100

700

5-15-35-50

55146

0.55818

47

0.85

53

Power supplyExternal finishOutdoor unit SUZ-KA25VA

SEZ-KA71VA

Standard: 30, Max: 5032-43

SEZ-KA35VA SEZ-KA50VA SEZ-KA60VA

167-217 200-283

SEZ-KA71VASUZ-KA71VA

SEZ-KA35VA SEZ-KA50VASUZ-KA35VA SUZ-KA50VA

SEZ-KA60VASUZ-KA61VA

Power supply

Indoor unitOutdoor unit

Function

SEZ-KD25VA/VAL SEZ-KD35VA/VAL SEZ-KD50VA/VAL

Power supply

92-1 16-150 116-150-183 166-208-250 200-250-300 200-266-333

23-26-30 30-34-38 30-35-4023-28-33

200

700

700

200

900

700

18 21

2010

55

3020

68850840330

EER Rated COP

EER Rated COP

3.33 3.65 2.76 3.21 2.76 2.77 2.89 3.38

Indoor unit*1

Indoor unit

Indoor unit*1

3.12 3.47 3.06 3.43 2.72 3.07 2.81 3.25 2.77 3.29

SEZ-KD models available with wireless remote controller.

Complies with AS/NZS 3823.2:2005 Clause 3.4 (Amdt1).

1

2

Page 9: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Our new state of the art Controller allows you to get the most out of your Mitsubishi Electric Ducted Air Conditioning System. To aid communication in today’s multicultural society, the control can be switched to 8 different languages.

Easy To Read DisplayThe large type in the dot Liquid Crystal Display allows the status of your system to be viewed at a glance, day or night.

While most remote controls can be confusing our control has been specifically designed to be more user friendly.

The Slimline styling has been designed to fit unobtrusively with any décor. The only visible buttons are those most frequently used: On/Off and Temperature Up/Down.

Total Control At Your FingertipsSimply open the front panel and total control of your comfort is there at the touch of a button. From temperature control to automatic stop/start on a daily or weekly basis, it’s all there at your fingertips.

Energy Saving ControlLimiting the set temperature range

Setting upper and lower temperature limits prevents the unit from excessive heating and cooling, thereby saving energy further and reducing your power bill.

Operation LockThe operation of all buttons on the control can be locked with the exception of the On/Off button. This stops little children or any unauthorised person changing temperatures or settings that may in turn waste valuable energy and increase running costs.

New Weekly TimerThe Weekly Timer allows you to programme the unit with up to 8 different automatic On/Off and Temperature changes per day, 7 days in advance, which means your home or office can be at the optimum temperature whenever required.

Versatility Is The Key To Comfort ControlTo allow you climate control of your home or office a number of Control System options are available. Three of the most popular are:

• LocatingtheSystemControlUnitinacentralposition,typically near the return air grille.

• MultipleControlUnits,eitherfixedorInfrared,positioned in different rooms, each of which can control your system.

• MultipleSystemscontrolledbytheirindividualControl Units or via one Central System Control which can be operated locally or “dialled into” through the World Wide Web, allowing you control of your system from anywhere in the world.

Easy Maintenance FunctionYour System Control can also give you a complete diagnostic on the condition of your indoor and outdoor units at the touch of a button, which means you can be sure that your system is operating efficiently at all times. In turn if any future service work is required, fault diagnostic time is drastically reduced.

French Russian Chinese Japanese

English Spanish Italian German

Control technology

Renovating air conditioning communication by advanced MA Remote Controller newly developed

The air conditioning operation can be switched off automatically thus prevent-

ing waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.

The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.

The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day.

Display can be switched over for 8 kinds of language.

Busy time frame

Setting to higher temperature

Less busy time frame

4

PAR-20MAAConventional MA remote controller

PAC-YT34STASchedule

timer PAR-21MAA-Gremote controller

Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowl-edgement capability. The operation and control status can be understood promptly.

Dot liquid crystal display section

Economical&

Space saving

26

25

24

23

22

0 10 12 14 16 18 20 22 24

Opening time

Lunch time Dinner time

Closing time

Setting to lower temperature

1

2

3 5

6 7

(Hr.)*Result of cooperative study with Japan Facility Solution Co, Ltd.

Recommend to use in

The lower temperatures cannot be selected.

Recommend to use in

* The “Simple timer” (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the “Auto off timer” by switching the function of the remote controller.

* The change of setting may be limited to the administrator who knows the method to release the locking.

Recommend to use inSetting to invalidate all buttons or the op-eration other than with ON/OFF button is

available. This always assures operation under an ade-quate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischie-vous operation.

*Based on our internal calculation

Easy maintenance information

(only for Power Inverter Mr. SLIM)

Reduces maintenance work drastically. Enables you to check operation data of the indoor and outdoor units by remote controller. Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.

(only for PUHZ-RP HA2)

The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function.With this function, the refrigerant leakage which may happen during a long period of use can be easily checkedwith a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind.

*The filter operating time is the time elapsed since the filter was reset.

NEW

NEW

ON/OFF TEMP.

Conventional inspection work

New improved method

Easy maintenance information

Accumulated operating time (x10 hours)

Number of ON/OFF times (x10 times)

Operating current (A)

Heat exchanger temperature (˚C)

Discharge temperature (˚C)

Outdoor temperature (˚C)

Intake air temperature (˚C)

Heat exchanger temperature (˚C)

Filter operating time* (Hours)

Outdoor unitCompressor Indoor unit

1

2

3

4

5

6

7

8

9

*The filter operating time is the time elapsed since the filter was reset.

Discharge temperature 64˚C

Indoor unit Outdoor unit

Measure the intake air temperature

Remove the service panel

Measure the discharge temperature

Measure the outdoor air temperature

Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.* The setting of the refrigerant add-

ress is required for outdoor unit.

Air conditioner can be started/stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA

(Example of 1 : 1 system)

Signal receiver

PAR-21MAAPAR-21MAA

(Example of 1 : 1 system)

(Example of 1 : 1 system)

(Example of 1 : 1 system)

PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally)

Adapter for remoteON/OFF

Adapter for remoteON/OFF

Indoor CN51

PAR-SL97A-E

PAR-SL97A-E

(Example of 1 : 1 system)

PAR-21MAA

(Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc.

Power supply unit

LOSSNAY operation cable

LOSSNAY

Wired remote controller

M-NET adapterPAC-SF80MA-E

Indoor CN51

Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub" remote controllers. * When you use wired and

wireless remote controllers

PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote ControllerPAR-21MAAWired Remote Controller Kit for PKAPAR-21MAAT-EWireless Remote ControllerPAR-SL97A-EWireless Remote Controller Kit for PCAPAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series,

no optional parts are required.)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter:PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remotedisplaypanel

Remotedisplaypanel

Indoor CN32

PAR-21MAA-G

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems.Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Adapter for remoteON/OFF

Adapter for remoteON/OFF

PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)Indoor CN51

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Operation/emergency signal canbe received at a distant place(no-voltage signal).

Weekly timer:ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)Simple timer:ON/OFF can be set once each within 72 hr. in a unit of one hour.Auto-off timer:Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals.*Simple timer and Auto off timer cannot be used at the same time.

Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)Remote ON/OFF adapterPAC-SE55RA-EConnector cable for remote displayPAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)Remote operation adapter PAC-SF40RM*Unable to use with wireless remote controllerRemote display panel (to be purchased locally)

MAC-397IF-E*

MAC-397IF-E*

MAC-397IF-E (Interface)

MAC-821SC-E (Centralized remote controller)

Centralized remote controller can be connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller.

Up to 8 indoor units can be switched ON/OFF with one remote controller.

Indoor unit

MAC-821SC-E

MAC-397IF-E

Outdoor unit

System Controls (P Series) Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25

66

8.04/9.74<cool/heat> (A)

(A)

(kg)

(kW)

hctiws PH ,omreht egrahcsiDhctiws PH ,omreht egrahcsiD

V: 32 Y: 16

69

V: 12.53/12.39 Y: 4.08/4.03

V: 32 Y: 16

70

V: 15.53/15.98 Y: 5.04/5.20

V: 40 Y: 16

71

V: 19.65/19.92 Y: 6.37/6.46

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

*These figures are only outdoor unit.

L/S

Sound power level

Breaker size (A)

(kg)

(kW)

Munsell 3.0Y 7.8/1.1

Single phase, 50Hz, 230V

3.158.0

49 (818)

53

55

68

0.55

34 (568) / 32 (534)

46

46

59

0.65

33 (551)

47

48

61

850

840

330

550

800

285

85353733

7

0302

2010

Cooling

Heating

Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size

<cool/heat> (A)

(A)

(kg)

(kW)

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

116121

Munsell 3Y 7.8/1.1

V514-083 ,zH05 ,esahp 3V042-022 ,zH05 ,esahp elgniS

0531349

059059

03+03303+033

4.7

59

56

59

77

5.5

130 (2167)

54

51

56

52

49

55

50

331621

32

30

70

Shell thermo, HP switch

9.47/9.88 11.0/12.0

848066

19.46/15.3818.24/15.6415.26/11.68

9.34.30.2

403225

20

50

Discharge thermo, HP switch

47

54

747270

70 (1170)60 (1000)

2007_SLIM_Aus 07.8.8 1:46 PM ページ 21

Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.* The setting of the refrigerant add-

ress is required for outdoor unit.

Air conditioner can be started/stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA

(Example of 1 : 1 system)

Signal receiver

PAR-21MAAPAR-21MAA

(Example of 1 : 1 system)

(Example of 1 : 1 system)

(Example of 1 : 1 system)

PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally)

Adapter for remoteON/OFF

Adapter for remoteON/OFF

Indoor CN51

PAR-SL97A-E

PAR-SL97A-E

(Example of 1 : 1 system)

PAR-21MAA

(Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc.

Power supply unit

LOSSNAY operation cable

LOSSNAY

Wired remote controller

M-NET adapterPAC-SF80MA-E

Indoor CN51

Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub" remote controllers. * When you use wired and

wireless remote controllers

PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote ControllerPAR-21MAAWired Remote Controller Kit for PKAPAR-21MAAT-EWireless Remote ControllerPAR-SL97A-EWireless Remote Controller Kit for PCAPAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series,

no optional parts are required.)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter:PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remotedisplaypanel

Remotedisplaypanel

Indoor CN32

PAR-21MAA-G

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems.Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Adapter for remoteON/OFF

Adapter for remoteON/OFF

PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)Indoor CN51

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Operation/emergency signal canbe received at a distant place(no-voltage signal).

Weekly timer:ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)Simple timer:ON/OFF can be set once each within 72 hr. in a unit of one hour.Auto-off timer:Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals.*Simple timer and Auto off timer cannot be used at the same time.

Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)Remote ON/OFF adapterPAC-SE55RA-EConnector cable for remote displayPAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)Remote operation adapter PAC-SF40RM*Unable to use with wireless remote controllerRemote display panel (to be purchased locally)

MAC-397IF-E*

MAC-397IF-E*

MAC-397IF-E (Interface)

MAC-821SC-E (Centralized remote controller)

Centralized remote controller can be connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller.

Up to 8 indoor units can be switched ON/OFF with one remote controller.

Indoor unit

MAC-821SC-E

MAC-397IF-E

Outdoor unit

System Controls (P Series) Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25

66

8.04/9.74<cool/heat> (A)

(A)

(kg)

(kW)

hctiws PH ,omreht egrahcsiDhctiws PH ,omreht egrahcsiD

V: 32 Y: 16

69

V: 12.53/12.39 Y: 4.08/4.03

V: 32 Y: 16

70

V: 15.53/15.98 Y: 5.04/5.20

V: 40 Y: 16

71

V: 19.65/19.92 Y: 6.37/6.46

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

*These figures are only outdoor unit.

L/S

Sound power level

Breaker size (A)

(kg)

(kW)

Munsell 3.0Y 7.8/1.1

Single phase, 50Hz, 230V

3.158.0

49 (818)

53

55

68

0.55

34 (568) / 32 (534)

46

46

59

0.65

33 (551)

47

48

61

850

840

330

550

800

285

85353733

7

0302

2010

Cooling

Heating

Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size

<cool/heat> (A)

(A)

(kg)

(kW)

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

116121

Munsell 3Y 7.8/1.1

V514-083 ,zH05 ,esahp 3V042-022 ,zH05 ,esahp elgniS

0531349

059059

03+03303+033

4.7

59

56

59

77

5.5

130 (2167)

54

51

56

52

49

55

50

331621

32

30

70

Shell thermo, HP switch

9.47/9.88 11.0/12.0

848066

19.46/15.3818.24/15.6415.26/11.68

9.34.30.2

403225

20

50

Discharge thermo, HP switch

47

54

747270

70 (1170)60 (1000)

2007_SLIM_Aus 07.8.8 1:46 PM ページ 21

Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.* The setting of the refrigerant add-

ress is required for outdoor unit.

Air conditioner can be started/stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA

(Example of 1 : 1 system)

Signal receiver

PAR-21MAAPAR-21MAA

(Example of 1 : 1 system)

(Example of 1 : 1 system)

(Example of 1 : 1 system)

PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally)

Adapter for remoteON/OFF

Adapter for remoteON/OFF

Indoor CN51

PAR-SL97A-E

PAR-SL97A-E

(Example of 1 : 1 system)

PAR-21MAA

(Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc.

Power supply unit

LOSSNAY operation cable

LOSSNAY

Wired remote controller

M-NET adapterPAC-SF80MA-E

Indoor CN51

Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub" remote controllers. * When you use wired and

wireless remote controllers

PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote ControllerPAR-21MAAWired Remote Controller Kit for PKAPAR-21MAAT-EWireless Remote ControllerPAR-SL97A-EWireless Remote Controller Kit for PCAPAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series,

no optional parts are required.)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter:PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remotedisplaypanel

Remotedisplaypanel

Indoor CN32

PAR-21MAA-G

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems.Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Adapter for remoteON/OFF

Adapter for remoteON/OFF

PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFFPAC-SE55RA-ERelay box (to be purchased locally)Remote control panel (to be purchased locally)Indoor CN51

Remotecontrolpanel

RemotecontrolpanelWired remote

controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operationis prohibited. Timer control is possible with an external timer.

Operation/emergency signal canbe received at a distant place(no-voltage signal).

Weekly timer:ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)Simple timer:ON/OFF can be set once each within 72 hr. in a unit of one hour.Auto-off timer:Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals.*Simple timer and Auto off timer cannot be used at the same time.

Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)Remote ON/OFF adapterPAC-SE55RA-EConnector cable for remote displayPAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)Remote operation adapter PAC-SF40RM*Unable to use with wireless remote controllerRemote display panel (to be purchased locally)

MAC-397IF-E*

MAC-397IF-E*

MAC-397IF-E (Interface)

MAC-821SC-E (Centralized remote controller)

Centralized remote controller can be connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller.

Up to 8 indoor units can be switched ON/OFF with one remote controller.

Indoor unit

MAC-821SC-E

MAC-397IF-E

Outdoor unit

System Controls (P Series) Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25

66

8.04/9.74<cool/heat> (A)

(A)

(kg)

(kW)

hctiws PH ,omreht egrahcsiDhctiws PH ,omreht egrahcsiD

V: 32 Y: 16

69

V: 12.53/12.39 Y: 4.08/4.03

V: 32 Y: 16

70

V: 15.53/15.98 Y: 5.04/5.20

V: 40 Y: 16

71

V: 19.65/19.92 Y: 6.37/6.46

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

*These figures are only outdoor unit.

L/S

Sound power level

Breaker size (A)

(kg)

(kW)

Munsell 3.0Y 7.8/1.1

Single phase, 50Hz, 230V

3.158.0

49 (818)

53

55

68

0.55

34 (568) / 32 (534)

46

46

59

0.65

33 (551)

47

48

61

850

840

330

550

800

285

85353733

7

0302

2010

Cooling

Heating

Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size

<cool/heat> (A)

(A)

(kg)

(kW)

Cooling mode

Silent mode

Heating mode

*These figures are only outdoor unit.

116121

Munsell 3Y 7.8/1.1

V514-083 ,zH05 ,esahp 3V042-022 ,zH05 ,esahp elgniS

0531349

059059

03+03303+033

4.7

59

56

59

77

5.5

130 (2167)

54

51

56

52

49

55

50

331621

32

30

70

Shell thermo, HP switch

9.47/9.88 11.0/12.0

848066

19.46/15.3818.24/15.6415.26/11.68

9.34.30.2

403225

20

50

Discharge thermo, HP switch

47

54

747270

70 (1170)60 (1000)

2007_SLIM_Aus 07.8.8 1:46 PM ページ 21

Controlling your comfort is easy in anyone’s language.

Control technology

Renovating air conditioning communication by advanced MA Remote Controller newly developed

The air conditioning operation can be switched off automatically thus prevent-

ing waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.

The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.

The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day.

Display can be switched over for 8 kinds of language.

Busy time frame

Setting to higher temperature

Less busy time frame

4

PAR-20MAAConventional MA remote controller

PAC-YT34STASchedule

timer PAR-21MAA-Gremote controller

Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowl-edgement capability. The operation and control status can be understood promptly.

Dot liquid crystal display section

Economical&

Space saving

26

25

24

23

22

0 10 12 14 16 18 20 22 24

Opening time

Lunch time Dinner time

Closing time

Setting to lower temperature

1

2

3 5

6 7

(Hr.)*Result of cooperative study with Japan Facility Solution Co, Ltd.

Recommend to use in

The lower temperatures cannot be selected.

Recommend to use in

* The “Simple timer” (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the “Auto off timer” by switching the function of the remote controller.

* The change of setting may be limited to the administrator who knows the method to release the locking.

Recommend to use inSetting to invalidate all buttons or the op-eration other than with ON/OFF button is

available. This always assures operation under an ade-quate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischie-vous operation.

*Based on our internal calculation

Easy maintenance information

(only for Power Inverter Mr. SLIM)

Reduces maintenance work drastically. Enables you to check operation data of the indoor and outdoor units by remote controller. Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.

(only for PUHZ-RP HA2)

The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function.With this function, the refrigerant leakage which may happen during a long period of use can be easily checkedwith a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind.

*The filter operating time is the time elapsed since the filter was reset.

NEW

NEW

Page 10: Mitsubishi Electric Ducted Air Conditioning Systems · PDF fileEnhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems

Publication effective August 2008. Specifications subject to change without notice. Printed in Australia.

Warm, even heat in winter and cool fresh air in summer is only a phone call or click away.Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about how to enhance your living environment. Our Specialists are fully qualified to give you all the right advice on which Mitsubishi Electric Ducted Air Conditioning System is right for you.

To locate your nearest Mitsubishi Electric Specialist go to our website www.mitsubishielectric.com.au They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for one of their Consultants to come to your home.

All Mitsubishi Electric Compact and Power Inverter Systems are MEPS (Minimum Efficiency Performance Standard) Compliant, so you can be sure that they will give you the performance and efficiency that they were designed to deliver.

Head Office Tokyo BUilding 2-7-3 MaRUnoUcHi, cHiyoda-kU 100-8310, JaPan

Mitsubishi Electric Shizuoka Works acquired ISO9001 certification under Series 9000 of the International Standard Organisation (ISO) based on a review of Quality warranties for the production of air conditioning equipment. The plant also acquired environmental management system standard ISO 14001 certification.

New South Wales348 Victoria RoadRydalmere NSW 2116Phone 02 9684 7555Fax 02 9898 1043

Victoria/TasmaniaSuite 28Omnico Business Park270 Ferntree Gully RoadNotting Hill VIC 3168Phone 03 9535 7800Fax 03 9535 7801

Queensland/Northern TerritoryUnit 12, 469 Nudgee RoadHendra QLD 4011Phone 07 3623 2000Fax 07 3630 1888

North QLD - TownsvilleMitsubishi Electric OfficePhone 07 4728 5223Fax 07 4728 5102Capricorn Air13 Mackley StreetGarbutt QLD 4814Phone 07 4775 5222Fax 07 4775 5305

South Australia77 Port RoadHindmarsh SA 5007Phone 08 8340 2000Fax 08 8340 0555

Western australiaUnit 5, 329 Collier RoadBassendean WA 6054Phone 08 9377 3400Fax 08 9377 3499

MITSUBISHI ELECTRIC AUSTRALIA PTY LTD.www.mitsubishielectric.com.au (Incorporated in New South Wales) ABN 58 001 215 792