2
NovoTouch Interacve Displays Displays Vivitek’s NovoTouch interacve touch displays can be controlled with Mira Connect™, Aveo Systems’ smart control appliance. Mira Connect communicates and controls NovoTouch interacve touch displays over an RS-232 connecon using a Global Caché IP2SL IP to serial adapter. Follow these steps to integrate an NovoTouch interacve touch display with Mira Connect: Add the NovoTouch interacve touch display to the room in Mira Portal (hps://mira.aveosystems.com), select the model number, enter the IP address of the display and press ‘add equipment’. Mira Connect will connect to the NovoTouch interacve touch display. Mira Portal will show the equipment status as a green circle if Mira Connect can communicate with the display, otherwise the warning symbol, ! , will appear indicang the IP address is not correct, Mira Connect ᨁ紁ḁ退 瘁紁騀 a network route to the disp ㄶ⸲y, the seri 褁紁谁騀 딁ᨀ 谩ㄹ⸳ate on the IP2SL is not set to 9600, or the seria ဩ㠮㜠⠁ 漁Ḁ 崁退 瘁紁騀 섁崁谩ㄱ⸲ed as sho⤲⸸wn in this document. S the troubleshoon 倀 逩㠮㔠⠁騩⸸ep⤴⸹s in this ᨁ紁ခ딁甁ḁ瘩㘮㌠⠁騀 騩㤮㠠⠁紀 崁送紁漁 issues before proceeding to the next step. Specify which vi ᨁḁ紀 崁瘁褁딁騁退 are used on the display by selecng Edit from the device’s menu, sel ḁခ鼁瘁倀 騁威Ḁ 猍IDEO INPUTS tab and enabling an input, sel ḁခ鼁瘁倀 崁ဍon, and entering text labels for the desired inputs. This will c 谩⸹eate a display menu as shown in the ⠩ㄹ⸶ollowing figures. The display menu wil 딁崁漁騀 and previewed on the VIDEO INPUTS tab within Mira Portal. An oponal d name may be entered which i 退 딁送ḩ㜠⠁⠁딁漀 崁⠀ 윩⸲ou ha⤱㔮㐠⠁쀩⸱e mulple ᨁ崁送褁漁 You can re-arrange the order of the items in the display menu by clicking 瘁ᨀ ᨁ谩ㄹagging an input. See the Mira Connect Administrators Guide for more informaon about using Mira Portal to set up Mira Connect. 192.168.44.102 Vivitek NovoTouch Equipment ADD 1 Step 2 Step ADD EQUIPMENT CANCEL Soft Codec ROOM COMPUTER Local Presentation LAPTOP Select source: Display Name (Optional) This menu will appear on Mira Connect. If you have more than one display, enter a name for each. Drag items to change order. The first item is the default selected input. Vivitek NovoTouch Add Equipment Equipment Type * Model * Icon Label Description (Optional) HDMI 3 ROOM COMPUTER Soft Codec Icon Label Description (Optional) Simulate equipment Universal PC HDMI 1 HDMI 2 Menu Preview CONNECTION VIDEO INPUTS LAPTOP Local Presentation Didn’t find your equipment? Request it! See the integration guide. Questions about Clevertouch Plus Series? i Display Power Select source: LAPTOP Local Presentaon Mira Connect Integraon R SYSTEMS Aveo Systems, Inc. 1791 West Oak Parkway Suite 8 Mariea, GA 30062 Phone: +1.678.653.7090 Fax: +1.844.fax.aveo Email: [email protected] www.aveosystems.com R SYSTEMS Connection failed ! 192.168.44.102 Vivitek NovoTouch Equipment ADD

Mira Connect Integration NovoTouch Interactive …Mira Connect communicates and controls NovoTouch interactive touch displays over an RS-232 connection using a Global Caché IP2SL

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Mira Connect Integration NovoTouch Interactive …Mira Connect communicates and controls NovoTouch interactive touch displays over an RS-232 connection using a Global Caché IP2SL

NovoTouch Interactive DisplaysDisplays

Vivitek’s NovoTouch interactive touch displays can be controlled with Mira Connect™, Aveo Systems’ smart control appliance. Mira Connect communicates and controls NovoTouch interactive touch displays over an RS-232 connection using a Global Caché IP2SL IP to serial adapter.

Follow these steps to integrate an NovoTouch interactive touch display with Mira Connect:

Add the NovoTouch interactive touch display to the room in Mira Portal (https://mira.aveosystems.com), select the model number, enter the IP address of the display and press ‘add equipment’. Mira Connect will connect to the NovoTouch interactive touch display.

Mira Portal will show the equipment status as a green circle if Mira Connect can communicate with the display, otherwise the warning symbol, ! , will appear indicating the IP address is not correct, Mira Connect does not have a network route to the display, the serial port baud rate on the IP2SL is not set to 9600, or the serial cable is not wired as shown in this document. See the troubleshooting steps in this document to isolate and correct those issues before proceeding to the next step.

Specify which video inputs are used on the display by selecting Edit from the device’s menu, selecting the VIDEO INPUTS tab and enabling an input, selecting an icon, and entering text labels for the desired inputs. This will create a display menu as shown in the following figures.

The display menu will be built and previewed on the VIDEO INPUTS tab within Mira Portal. An optional display name may be entered which is useful if you have multiple displays in a room. You can re-arrange the order of the items in the display menu by clicking and dragging an input.

See the Mira Connect Administrators Guide for more information about using Mira Portal to set up Mira Connect.

192.168.44.102

Vivitek NovoTouch

Equipment ADD

1Step

2Step

ADD EQUIPMENTCANCEL

Soft CodecROOM COMPUTER

Local PresentationLAPTOP

Select source:

Display Name (Optional)

This menu will appear on Mira Connect. If you have more than one display, enter a name for each. Drag items to change order. The first item is the default selected input.

Vivitek NovoTouch

Add Equipment

Equipment Type * Model *

Icon Label

Description (Optional)

HDMI 3 ROOM COMPUTER

Soft Codec

Icon Label

Description (Optional)

Simulate equipmentUniversal

PC

HDMI 1

HDMI 2

Menu Preview

CONNECTION VIDEO INPUTS

LAPTOP

Local Presentation

Didn’t find your equipment? Request it!

See the integration guide.Questions about Clevertouch Plus Series?i

Display Power

Select source:

LAPTOPLocal Presentation

Mira Connect Integration

R

S Y S T E M S

Aveo Systems, Inc. • 1791 West Oak Parkway • Suite 8 • Marietta, GA 30062 • Phone: +1.678.653.7090 Fax: +1.844.fax.aveo • Email: [email protected] • www.aveosystems.com

R

S Y S T E M S

Connection failed

!192.168.44.102

Vivitek NovoTouch

Equipment ADD

Page 2: Mira Connect Integration NovoTouch Interactive …Mira Connect communicates and controls NovoTouch interactive touch displays over an RS-232 connection using a Global Caché IP2SL

R

S Y S T E M S

For more information please contact our Sales Department at [email protected].

About Aveo SystemsAveo Systems is a leading provider of intuitive and easy-to-use solutions for audio, video, and collaboration, improving how systems are used and managed by customers world-wide.

DS-11055-001 Version 20200315

Specifications subject to change without notice. Aveo Systems and the Aveo logo are registered trademarks. All other trademarks are the property of their respective owners.

Mira Connect Integration with the NovoTouch interactive touch display Displays

Important information about the integration is summarized below.

Control Interface

Network connection using TCP, port 4999 using the Global Caché IP2SL device. Set a static IP address, or use a ‘reserved’ lease on a DHCP server to ensure the IP address of the Global Caché IP2SL does not change over time.

The default RS-232 baud rate for the display 9,600 baud. Since the default baud rate of the Global Caché IP2SL interface is 19,200 baud, you must change the baud rate on the Global Caché IP2SL interface to 9,600.

See the Global Caché integration guide for how to change the baud rate and how to set a static IP address.

RS-232 control requires a 9-Pin Female to 9-Pin Female straight-through cable as shown in the following figure.

Equipment to beControlled

Global Cache IP2SL

Pin 1Pin 5

Pin 9 Pin 6

Pin Signal12 RX3 TX45 Ground6789

DB9 FemalePin 1Pin 5

Pin 9 Pin 6

Pin 5Pin 1

Pin 6 Pin 9

DB9 FemaleDB9 Female

Pin Signal1 2 TX3 RX45 Ground6789

DB9 Male

Straight-Through RS-232 Control Cable DB9F - DB9F

RS-232 Connectoris DB9 Male

RS-232 connectoris DB9 Male

Supported ControlSupports video source selection, power control, volume control, and mute of the display audio.

Supported ModelsMira Connect supports all Clevertouch displays that utilize the API.

Software VersionsTested against the Clevertouch Plus series API.

TroubleshootingIf the display does shows a Connection failed message, check:

1. The RS-232 cable is wired as described in this document. Use a multi-meter to check continuity between the pins.

2. The Global Caché IP2SL’s baud rate is set to 9,600 bps as described in the Global Caché integration guide.3. The IP address of the Global Caché device is correct and Mira Connect has a route to that IP address.4. You have a static IP address or reserved lease for the IP address of the Global Caché IP2SL so that IP address doesn’t

change after a power outage.

See our RS-232 best practices article for best practices when using RS-232.

Connection failed

!192.168.44.102

Vivitek NovoTouch

Equipment ADD