MINERvA Calorimetry Calibration with infinite d etector Jaewon Park University of Rochester piter/MINERvA Group Meeting, Nov 15, 2006

MINERvA Calorimetry Calibration with infinite detector

  • Upload
    jael

  • View
    42

  • Download
    0

Embed Size (px)

DESCRIPTION

MINERvA Calorimetry Calibration with infinite detector. Jaewon Park University of Rochester. Jupiter/MINER v A Group Meeting, Nov 15, 2006. Infinite ID gap dependence. Angle: 0deg (perpendicular to detector) Gap difference gives ~1% contribution. Infinite DS-HCAL. No gaps - PowerPoint PPT Presentation

Citation preview

Page 1: MINERvA Calorimetry Calibration with infinite detector

MINERvA CalorimetryCalibration with infinite detector

Jaewon Park

University of Rochester

Jupiter/MINERvA Group Meeting, Nov 15, 2006

Page 2: MINERvA Calorimetry Calibration with infinite detector

2

Infinite ID gap dependence

Angle: 0deg (perpendicular to detector) Gap difference gives ~1% contribution

Page 3: MINERvA Calorimetry Calibration with infinite detector

3

Infinite DS-HCAL

No gapsProton beam energy: 1, 1.5, … 5GeVAngle: 0, 10, … 60deg

0deg means perpendicular to DS-HCAL

Page 4: MINERvA Calorimetry Calibration with infinite detector

4

Infinite DS-HCAL

Page 5: MINERvA Calorimetry Calibration with infinite detector

5

Infinite OD

With gapsIron width: 3, 5, 7, 10cmProton beam energy: 1, 1.5, … 5GeVAngle: 30, 40, … 80deg

90deg means perpendicular to OD

Page 6: MINERvA Calorimetry Calibration with infinite detector

6

Infinite OD (3cm iron)

Page 7: MINERvA Calorimetry Calibration with infinite detector

7

Infinite OD (5cm iron)

Page 8: MINERvA Calorimetry Calibration with infinite detector

8

Infinite OD (7cm iron)

Page 9: MINERvA Calorimetry Calibration with infinite detector

9

Infinite OD (10cm iron)

Page 10: MINERvA Calorimetry Calibration with infinite detector

10

Infinite OD (summary)

Page 11: MINERvA Calorimetry Calibration with infinite detector

11

Summary Calibration constants are calculated for ID, DS-HCA

L, OD ID

Gap dependence Average over beam energy

DS-HCAL Average over beam energy and angle(0 to 50deg)

OD Iron width dependence Average over beam energy and angle(30 to 80deg)

Next step is to test those calibration constants with composite detectors (ID+DSHCAL and ID+OD)

Page 12: MINERvA Calorimetry Calibration with infinite detector

12

ID + infinite DS-HCAL

No gaps in ID and DS-HCAL Angle: 0deg (perpendicular to detector) Proton beam energy: 1, 1.5, … 5GeV ID track length: 476, 376, 276, 176, 76, 26cm

~2% deviation from beam energy

Page 13: MINERvA Calorimetry Calibration with infinite detector

13

ID + infinite OD

With gaps in ID and OD4 types of ID+OD: iron width=3, 5, 7, 10cmProton beam energy: 1, 1.5, … 5GeVAngle = 50deg

This is middle point of previous calibration(30 to 80deg)

ID track length: -100, -80, -40, 0, 40, 80, 100cm from center

Page 14: MINERvA Calorimetry Calibration with infinite detector

14

ID+Infinite OD

Iron width: 3cm

Iron width: 5cm

Page 15: MINERvA Calorimetry Calibration with infinite detector

15

ID+Infinite OD

Iron width: 7cm

Iron width: 10cm

Page 16: MINERvA Calorimetry Calibration with infinite detector

16

ID+Infinite OD (summary)

Calibration doesn’t work very well

~5-10% lesser than beam energy

Page 17: MINERvA Calorimetry Calibration with infinite detector

17

Calibration without back-scattered particles

When ID track length=0, it should be 1 Back-scattered particle can’t contribute DS-HCAL for composi

te detector

When ID track length is large, it’s ID only geometry

Two end point should be 1 With new calibration for DS-HCAL

Page 18: MINERvA Calorimetry Calibration with infinite detector

18

Calibration without back-scattered particles

It doesn’t help very much for OD

With new calibration for OD

Page 19: MINERvA Calorimetry Calibration with infinite detector

19

Next try

I don’t want change ID calibration Relative OD calibration doesn’t help It would be best to make flat in the central region a

nd to scale (ID+OD)

5cm OD

Page 20: MINERvA Calorimetry Calibration with infinite detector

20

Another try

First of all, I used different OD calibrations for 5, 7, 10cm OD to make close to 3cm OD curve

Then, scale (ID+OD) to make it near 1 Scale factor was 1.03 I hope to use same ID calibration for DS-HCAL and OD

Page 21: MINERvA Calorimetry Calibration with infinite detector

21

Summary

Individual calibration didn’t work very well for ID+OD.

It seems best to calibrating with combined detector which requires constant total energy over different ID track length.

Next step is leakage study