Upload
kronikloops
View
80
Download
11
Embed Size (px)
DESCRIPTION
Rosemount Temperature Transmiters Module 3
Citation preview
Temperature Level 200:Temperature Level 200:TransmittersTransmitters
Module 3 Module 3
Capability
Value
Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth
04
3144PMultivariableField mount
Safety Transmitter
34204 H1 Ff Segments
248Head mount
Rail mount
144Head mountPC-Programmable
648 WirelessFieldmount
644Head & Rail mount
848T Multi-InputRail mount
Rosemount 648: The Single-Point Wireless Temperature SolutionRosemount 648: The SingleRosemount 648: The Single--Point Wireless Point Wireless Temperature SolutionTemperature Solution
LCD Display Local process and diagnostic indication
Dual Compartment Housing Improves measurement reliability in high humidity, corrosive, and EMI/RFI environments
Transmitter-Sensor Matching Provides highest accuracy and repeatability by eliminating sensor interchangeability error
Variety of Sensor Inputs 2, 3 and 4-wire RTD, T/C ohm, and mV
Ambient Temperature Compensation Reduces measurement error in harsh applications, especially wide fluctuations of ambient temperatures
Smart PowerTM Battery 8 year battery lifetime (1 min. update rate)
Field Replaceable
Diagnostics and Alerts 4 configurable alarms
Rich HART Data & Diagnostics
Single Input
Supported Sensor Types
Thermocouples, 2- 3- 4-wire RTDs, Ohms, mV
Accepts 4-20mA input
Temperature Sensor Diagnostics
Open or short diagnostics
4 User Configurable Alerts
Smart Power Battery
8 year life
Engineered Solution
Intrinsically Safe
IS Class 1 Div 1 Approvals
CPS Offering
Rosemount 648Wireless Temperature TransmitterRosemount 648Rosemount 648Wireless Temperature TransmitterWireless Temperature Transmitter
Capability
Value
Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth
04
3144PMultivariableField mount
Safety Transmitter
34204 H1 Ff Segments
248Head mount
Rail mount
144Head mountPC-Programmable
648 WirelessFieldmount
644Head & Rail mount
848T Multi-InputRail mount
Dual Compartment Housing Superior EMI/RFI Handling
Electronic Isolation
3144P Features Provide Unmatched Differentiation with Measurable Benefits3144P Features Provide Unmatched 3144P Features Provide Unmatched Differentiation with Measurable BenefitsDifferentiation with Measurable Benefits
Multiple Protocols HART
FOUNDATION Fieldbus
Increased Performance Ambient Temperature Compensation
5 year stability rating
Transmitter-Sensor Matching
Hardware Features Integral Transient Protection
Failure Mode Switch (HART)
LCD Display
SIS Certification Meets Industrial Standards
More Rigorous Testing
Dual Sensors Measurement Redundancy
Increased Safety
Hot Backup
Advanced Diagnostics Statistical Process Monitoring
Sensor Drift Alert
Sensor 1Good
Sensor 2Good
125.5FSNSR 1
125.3FSNSR 2BACKUP
Seamless TransferTo Sensor 2 if Sensor 1 Fails
Sensor 1Open
User alertedVia LCD, Field Communicator,
Or Diagnostic Software
Critical Application
Dual Sensors for Measurement RedundancyDual Sensors Dual Sensors for Measurement Redundancyfor Measurement Redundancy
Hot Backup ensures plant productivity and safety by using two measurement points.
All sensors drift due to:
Vibration and mechanical shock
Temperature swings
Contamination
Moisture
3144P: Sensor Drift Alert
Digital AlertCommunicatedwhen T exceedsuser defined limit.
T measured betweentwo sensors measuringsame process temp.
Advanced Diagnostics with Sensor Drift AlertAdvanced Diagnostics Advanced Diagnostics with Sensor Drift Alert
Time
Normal Sensor Operation
P
r
o
c
e
s
s
T
e
m
p
e
r
a
t
u
r
e
User Definable
Drift Limit Exceeded
Alert Issued
Advanced Diagnostics with Statistical Process Monitoring (SPM)Advanced Diagnostics Advanced Diagnostics with Statistical Process Monitoring (SPM)
Option Code: D01
SPM detects abnormal process behavior before operating problems occur:
Leakages Pressure Changes Clogging Equipment Malfunction
Ambient Condition Changes Temperature Changes
Process Change
Quality Limits
Standard Process Variations
SPM Threshold
Standard DeviationSPM PlantWeb Alert Issued
Control System Samples May miss peeks therefore, no warning
ElectronicsCompartment
TerminalCompartment
Ambient Moisture
Corrosive Environment
EMI/RFI
Water In Conduits
Transition Pins:Environmentally Sealed
Electromagnetically Filtered
Dual Compartment Housings for Best ReliabilityDual Compartment HousingsDual Compartment Housings for Best for Best ReliabilityReliability
The housing isolates the circuit board from the sensor.
Transmitter Drift With Time
3144P3144P 2 Year Stability Transmitter2 Year Stability Transmitter
18 Month Stability Transmitter18 Month Stability Transmitter3144P3144P
Rosemount Saves $60 Per TransmitterEvery 5 Years vs Competitor ACompetitor A
Rosemount Saves $90 Per TransmitterEvery 5 Years vs Competitor BCompetitor B
Transmitter Drift With Time
0
0.05
0.1
0.15
0.2
0.25
0 12 24 36 48 60
Enhanced Stability Saves MoneyEnhanced Stability Enhanced Stability Saves MoneySaves Money
0
0.05
0.1
0.15
0.2
0.25
0 12 24 36 48 60
5-Year Stability Reduces Maintenance CostsOver Industry Standard 1 to 2 Year Stability
Sensor Matching to Improve Measurement AccuracySensor Matching Sensor Matching to Improve Measurement to Improve Measurement AccuracyAccuracy
Standard Sensor& 3144P
.9F 1.8F 2.7F
Matched Sensor& 3144P
.9F 1.8F 2.7F
Better Accuracy
by 70%+70%+
Option Code: C2
Hardware Features Hardware Features Hardware Features Integral Transient
ProtectionLCD
Prevents transmitter damage from lightning, welding, heavy electrical equipment, or switch gears.
Comes with the external ground lug assembly (Option G1)
Rotates
Easy to read
Customizable Display Options
Option Code: M5
Option Code: T1
The Rosemount 3144P and FOUNDATION FieldbusThe Rosemount 3144P and The Rosemount 3144P and FOUNDATION FieldbusFOUNDATION Fieldbus
Enhanced Functionality
Lower Power Consumption
Advanced Diagnostics
Statistical Process Monitoring
Thermocouple Diagnostic
Min/Max Tracking
Enhanced LCD
Arithmatic Block
Characterizer Block
Benefits:Benefits:
Note: The 3144P FF utilizes all of the standard
advantages of FOUNDATION Fieldbus.
Enhanced Function Block with LCD DisplayEnhanced Function Block Enhanced Function Block with LCD Display
Provides local indication of process temperature and diagnostics on a rotating LCD display
3144P can display up to 4 variables on its LCD from any device on the same H1 Segment
TT101
234.5C
PT137
27.5 ar
TT102 - 31.44 F
PT137 - 27.5 Bar
TT101 - 234.5 C
TT137 - 125.5 F
TT137
125.5F
Emerson Confidential
Slide 15
Lower Power Consumption Only 11mA (Instead of 17.5mA)Lower Power Consumption Lower Power Consumption Only 11mA (Instead of 17.5mA)
CONTROL ROOM EQUIPMENT
Using a 80 mAbarrier
Cable
Hazardous Area Safe Area
I.S.Barrier
3144P Hart only 4 transmitters per I.S. barrierClass 1 Div 1 / Zone 0
3144P can have 6 transmitters per I.S. barrier
3144P Benefits: 2 additional devices
per Intrinsically Safe H1
segment
3144P SIS Certification: 3144P SIS Certification: 3144P SIS Certification: SIS retains all of the 3144P HART features
SIS adds Safety Certification
IEC61508 SIL-2
Follows industrystandards
Meets certain industry requirements
Certificates, labeling, and SIS-colored module
SIS adds Rigorous 3rd Party Testing
3144P SIS is available only in HART Communication
For Additional SIS InformationFor Additional SIS InformationFor Additional SIS Information
Rosemount.com
FAQs
White papers
SIS Options
Exida.com
Testing Specifications
Value Selling Matrix
Customer presentations
Manuals
Sample Certifications
Check for KnowledgeCheck forCheck for KnowledgeKnowledge
What does a transmitter with Dual Compartment What does a transmitter with Dual Compartment housing protect against? housing protect against?
A) Mechanical Shock
B) DIN A Design Flaws
D) Sensor Degredation
C) EMI/RFI Interference
What do you have to use to utilize the hot backup What do you have to use to utilize the hot backup function?function?
A) HART Communications
B) Foundation Fieldbus
C) Sensor Drift Enabled
D) Dual Sensors
Capability
Value
Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth
04
3144PMultivariableField mount
Safety Transmitter
34204 H1 Ff Segments
248Head mount
Rail mount
144Head mountPC-Programmable
648 WirelessFieldmount
644Head & Rail mount
848T Multi-InputRail mount
Temperature Transmitter DifferentiationTemperature Transmitter DifferentiationTemperature Transmitter Differentiation
Feature 144H 248 848T Customer Benefit
Communication Protocols4-20 mA
PC-Programmable
HART
PC-Programmable
Option
FOUNDATION fieldbusIncreased flexibility by using open
digital protocols
Sensor Inputs 1 1 8Multivariable capability provides
lowest installed cost solution
LCD MeterUse with 752 for Local
FF IndicationLocal Temperature Indications
Digital Accuracy Pt100 0.10% of span or 0.30
C, whichever is greater
0.10% of span or 0.20
C, whichever is greater 0.30 C
Economically provides adequate
process performance for
monitoring applications
Stability 1-year 1-yearReduces maintenance costs with
fewer required calibrations
Transmitter-Sensor
Matching (CVD)
Improves measurement accuracy
by 75%
Differential Temp
Reduces cost and process
variability by performing 8T
calculations in one transmitter
Average, Minimum, and
Maximum Temp
Reduces cost, frees up DCS
resources by performing
calculations in transmitter
Third Party Validated
FMEDA Report
Ensures accurate results for a
SIL level calculation in a Safety
Instrument System (SIS)
Temperature Transmitter DifferentiationTemperature Transmitter DifferentiationTemperature Transmitter Differentiation
Feature 644H/R 644H 3144P 3144P Customer Benefit
Communication
ProtocolsHART
FOUNDATION
fieldbusHART
FOUNDATION
fieldbus
Increased flexibility by using open digital
protocols
Sensor Inputs 1 1 2 2Better availability from multivariable
capability or lower cost per measurement
LCD Meter Head
mountLocal Temperature indications
Digital Accuracy Pt100 0.15 C
( 0.27 F)
0.15 C
( 0.27 F)
0.10 C
( 0.18 F)
0.10 C
( 0.18 F)
Better accuracy improves process
performance
Stability 2-year 2-year 5-year 5-yearReduces maintenance costs with fewer
required calibrations
Transmitter-Sensor
Matching (CVD)Improves measurement accuracy by 75%
Differential Temp
Reduces cost and process variability by
performing T calculations in one
transmitter instead of two
Average Temp
Reduces cost and process variability and
cost by performing average calculation in
1 transmitter instead of 2
Third Party Validated
FMEDA ReportN/A
Exida Certified
and FMEDA N/A
Ensures accurate results for a SIL level
calculation in a Safety Instrument System
(SIS)
Check for KnowledgeCheck forCheck for KnowledgeKnowledge
Which device is ideal for high density Which device is ideal for high density measurements? measurements?
A) 3144P
C) 144
D) 3051S
B) 848T
What device is ideal for a customer who wants the What device is ideal for a customer who wants the most basic of temperature measurements?most basic of temperature measurements?
A) 3144P
B) 248
D) 644
C) 144
SummarySummarySummary
This section has helped you:
Understand how a transmitter works
Understand the advantages of using a transmitter over wiring direct
Understand the key features and benefits of the Rosemount 144, 248, 848T, 644, 648, and 3144P temperature transmitters