  • Temperature Level 200:Temperature Level 200:TransmittersTransmitters

    Module 3 Module 3

  • Capability

    Value

    Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth

    04

    3144PMultivariableField mount

    Safety Transmitter

    34204 H1 Ff Segments

    248Head mount

    Rail mount

    144Head mountPC-Programmable

    648 WirelessFieldmount

    644Head & Rail mount

    848T Multi-InputRail mount

  • Rosemount 648: The Single-Point Wireless Temperature SolutionRosemount 648: The SingleRosemount 648: The Single--Point Wireless Point Wireless Temperature SolutionTemperature Solution

    LCD Display Local process and diagnostic indication

    Dual Compartment Housing Improves measurement reliability in high humidity, corrosive, and EMI/RFI environments

    Transmitter-Sensor Matching Provides highest accuracy and repeatability by eliminating sensor interchangeability error

    Variety of Sensor Inputs 2, 3 and 4-wire RTD, T/C ohm, and mV

    Ambient Temperature Compensation Reduces measurement error in harsh applications, especially wide fluctuations of ambient temperatures

    Smart PowerTM Battery 8 year battery lifetime (1 min. update rate)

    Field Replaceable

    Diagnostics and Alerts 4 configurable alarms

  • Rich HART Data & Diagnostics

    Single Input

    Supported Sensor Types

    Thermocouples, 2- 3- 4-wire RTDs, Ohms, mV

    Accepts 4-20mA input

    Temperature Sensor Diagnostics

    Open or short diagnostics

    4 User Configurable Alerts

    Smart Power Battery

    8 year life

    Engineered Solution

    Intrinsically Safe

    IS Class 1 Div 1 Approvals

    CPS Offering

    Rosemount 648Wireless Temperature TransmitterRosemount 648Rosemount 648Wireless Temperature TransmitterWireless Temperature Transmitter

  • Capability

    Value

    Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth

    04

    3144PMultivariableField mount

    Safety Transmitter

    34204 H1 Ff Segments

    248Head mount

    Rail mount

    144Head mountPC-Programmable

    648 WirelessFieldmount

    644Head & Rail mount

    848T Multi-InputRail mount

  • Dual Compartment Housing Superior EMI/RFI Handling

    Electronic Isolation

    3144P Features Provide Unmatched Differentiation with Measurable Benefits3144P Features Provide Unmatched 3144P Features Provide Unmatched Differentiation with Measurable BenefitsDifferentiation with Measurable Benefits

    Multiple Protocols HART

    FOUNDATION Fieldbus

    Increased Performance Ambient Temperature Compensation

    5 year stability rating

    Transmitter-Sensor Matching

    Hardware Features Integral Transient Protection

    Failure Mode Switch (HART)

    LCD Display

    SIS Certification Meets Industrial Standards

    More Rigorous Testing

    Dual Sensors Measurement Redundancy

    Increased Safety

    Hot Backup

    Advanced Diagnostics Statistical Process Monitoring

    Sensor Drift Alert

  • Sensor 1Good

    Sensor 2Good

    125.5FSNSR 1

    125.3FSNSR 2BACKUP

    Seamless TransferTo Sensor 2 if Sensor 1 Fails

    Sensor 1Open

    User alertedVia LCD, Field Communicator,

    Or Diagnostic Software

    Critical Application

    Dual Sensors for Measurement RedundancyDual Sensors Dual Sensors for Measurement Redundancyfor Measurement Redundancy

    Hot Backup ensures plant productivity and safety by using two measurement points.

  • All sensors drift due to:

    Vibration and mechanical shock

    Temperature swings

    Contamination

    Moisture

    3144P: Sensor Drift Alert

    Digital AlertCommunicatedwhen T exceedsuser defined limit.

    T measured betweentwo sensors measuringsame process temp.

    Advanced Diagnostics with Sensor Drift AlertAdvanced Diagnostics Advanced Diagnostics with Sensor Drift Alert

    Time

    Normal Sensor Operation

    P

    r

    o

    c

    e

    s

    s

    T

    e

    m

    p

    e

    r

    a

    t

    u

    r

    e

    User Definable

    Drift Limit Exceeded

    Alert Issued

  • Advanced Diagnostics with Statistical Process Monitoring (SPM)Advanced Diagnostics Advanced Diagnostics with Statistical Process Monitoring (SPM)

    Option Code: D01

    SPM detects abnormal process behavior before operating problems occur:

    Leakages Pressure Changes Clogging Equipment Malfunction

    Ambient Condition Changes Temperature Changes

    Process Change

    Quality Limits

    Standard Process Variations

    SPM Threshold

    Standard DeviationSPM PlantWeb Alert Issued

    Control System Samples May miss peeks therefore, no warning

  • ElectronicsCompartment

    TerminalCompartment

    Ambient Moisture

    Corrosive Environment

    EMI/RFI

    Water In Conduits

    Transition Pins:Environmentally Sealed

    Electromagnetically Filtered

    Dual Compartment Housings for Best ReliabilityDual Compartment HousingsDual Compartment Housings for Best for Best ReliabilityReliability

    The housing isolates the circuit board from the sensor.

  • Transmitter Drift With Time

    3144P3144P 2 Year Stability Transmitter2 Year Stability Transmitter

    18 Month Stability Transmitter18 Month Stability Transmitter3144P3144P

    Rosemount Saves $60 Per TransmitterEvery 5 Years vs Competitor ACompetitor A

    Rosemount Saves $90 Per TransmitterEvery 5 Years vs Competitor BCompetitor B

    Transmitter Drift With Time

    0

    0.05

    0.1

    0.15

    0.2

    0.25

    0 12 24 36 48 60

    Enhanced Stability Saves MoneyEnhanced Stability Enhanced Stability Saves MoneySaves Money

    0

    0.05

    0.1

    0.15

    0.2

    0.25

    0 12 24 36 48 60

    5-Year Stability Reduces Maintenance CostsOver Industry Standard 1 to 2 Year Stability

  • Sensor Matching to Improve Measurement AccuracySensor Matching Sensor Matching to Improve Measurement to Improve Measurement AccuracyAccuracy

    Standard Sensor& 3144P

    .9F 1.8F 2.7F

    Matched Sensor& 3144P

    .9F 1.8F 2.7F

    Better Accuracy

    by 70%+70%+

    Option Code: C2

  • Hardware Features Hardware Features Hardware Features Integral Transient

    ProtectionLCD

    Prevents transmitter damage from lightning, welding, heavy electrical equipment, or switch gears.

    Comes with the external ground lug assembly (Option G1)

    Rotates

    Easy to read

    Customizable Display Options

    Option Code: M5

    Option Code: T1

  • The Rosemount 3144P and FOUNDATION FieldbusThe Rosemount 3144P and The Rosemount 3144P and FOUNDATION FieldbusFOUNDATION Fieldbus

    Enhanced Functionality

    Lower Power Consumption

    Advanced Diagnostics

    Statistical Process Monitoring

    Thermocouple Diagnostic

    Min/Max Tracking

    Enhanced LCD

    Arithmatic Block

    Characterizer Block

    Benefits:Benefits:

    Note: The 3144P FF utilizes all of the standard

    advantages of FOUNDATION Fieldbus.

  • Enhanced Function Block with LCD DisplayEnhanced Function Block Enhanced Function Block with LCD Display

    Provides local indication of process temperature and diagnostics on a rotating LCD display

    3144P can display up to 4 variables on its LCD from any device on the same H1 Segment

    TT101

    234.5C

    PT137

    27.5 ar

    TT102 - 31.44 F

    PT137 - 27.5 Bar

    TT101 - 234.5 C

    TT137 - 125.5 F

    TT137

    125.5F

    Emerson Confidential

    Slide 15

  • Lower Power Consumption Only 11mA (Instead of 17.5mA)Lower Power Consumption Lower Power Consumption Only 11mA (Instead of 17.5mA)

    CONTROL ROOM EQUIPMENT

    Using a 80 mAbarrier

    Cable

    Hazardous Area Safe Area

    I.S.Barrier

    3144P Hart only 4 transmitters per I.S. barrierClass 1 Div 1 / Zone 0

    3144P can have 6 transmitters per I.S. barrier

    3144P Benefits: 2 additional devices

    per Intrinsically Safe H1

    segment

  • 3144P SIS Certification: 3144P SIS Certification: 3144P SIS Certification: SIS retains all of the 3144P HART features

    SIS adds Safety Certification

    IEC61508 SIL-2

    Follows industrystandards

    Meets certain industry requirements

    Certificates, labeling, and SIS-colored module

    SIS adds Rigorous 3rd Party Testing

    3144P SIS is available only in HART Communication

  • For Additional SIS InformationFor Additional SIS InformationFor Additional SIS Information

    Rosemount.com

    FAQs

    White papers

    SIS Options

    Exida.com

    Testing Specifications

    Value Selling Matrix

    Customer presentations

    Manuals

    Sample Certifications

  • Check for KnowledgeCheck forCheck for KnowledgeKnowledge

  • What does a transmitter with Dual Compartment What does a transmitter with Dual Compartment housing protect against? housing protect against?

    A) Mechanical Shock

    B) DIN A Design Flaws

    D) Sensor Degredation

    C) EMI/RFI Interference

  • What do you have to use to utilize the hot backup What do you have to use to utilize the hot backup function?function?

    A) HART Communications

    B) Foundation Fieldbus

    C) Sensor Drift Enabled

    D) Dual Sensors

  • Capability

    Value

    Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth Rosemount Temperature Breadth and Depth

    04

    3144PMultivariableField mount

    Safety Transmitter

    34204 H1 Ff Segments

    248Head mount

    Rail mount

    144Head mountPC-Programmable

    648 WirelessFieldmount

    644Head & Rail mount

    848T Multi-InputRail mount

  • Temperature Transmitter DifferentiationTemperature Transmitter DifferentiationTemperature Transmitter Differentiation

    Feature 144H 248 848T Customer Benefit

    Communication Protocols4-20 mA

    PC-Programmable

    HART

    PC-Programmable

    Option

    FOUNDATION fieldbusIncreased flexibility by using open

    digital protocols

    Sensor Inputs 1 1 8Multivariable capability provides

    lowest installed cost solution

    LCD MeterUse with 752 for Local

    FF IndicationLocal Temperature Indications

    Digital Accuracy Pt100 0.10% of span or 0.30

    C, whichever is greater

    0.10% of span or 0.20

    C, whichever is greater 0.30 C

    Economically provides adequate

    process performance for

    monitoring applications

    Stability 1-year 1-yearReduces maintenance costs with

    fewer required calibrations

    Transmitter-Sensor

    Matching (CVD)

    Improves measurement accuracy

    by 75%

    Differential Temp

    Reduces cost and process

    variability by performing 8T

    calculations in one transmitter

    Average, Minimum, and

    Maximum Temp

    Reduces cost, frees up DCS

    resources by performing

    calculations in transmitter

    Third Party Validated

    FMEDA Report

    Ensures accurate results for a

    SIL level calculation in a Safety

    Instrument System (SIS)

  • Temperature Transmitter DifferentiationTemperature Transmitter DifferentiationTemperature Transmitter Differentiation

    Feature 644H/R 644H 3144P 3144P Customer Benefit

    Communication

    ProtocolsHART

    FOUNDATION

    fieldbusHART

    FOUNDATION

    fieldbus

    Increased flexibility by using open digital

    protocols

    Sensor Inputs 1 1 2 2Better availability from multivariable

    capability or lower cost per measurement

    LCD Meter Head

    mountLocal Temperature indications

    Digital Accuracy Pt100 0.15 C

    ( 0.27 F)

    0.15 C

    ( 0.27 F)

    0.10 C

    ( 0.18 F)

    0.10 C

    ( 0.18 F)

    Better accuracy improves process

    performance

    Stability 2-year 2-year 5-year 5-yearReduces maintenance costs with fewer

    required calibrations

    Transmitter-Sensor

    Matching (CVD)Improves measurement accuracy by 75%

    Differential Temp

    Reduces cost and process variability by

    performing T calculations in one

    transmitter instead of two

    Average Temp

    Reduces cost and process variability and

    cost by performing average calculation in

    1 transmitter instead of 2

    Third Party Validated

    FMEDA ReportN/A

    Exida Certified

    and FMEDA N/A

    Ensures accurate results for a SIL level

    calculation in a Safety Instrument System

    (SIS)

  • Check for KnowledgeCheck forCheck for KnowledgeKnowledge

  • Which device is ideal for high density Which device is ideal for high density measurements? measurements?

    A) 3144P

    C) 144

    D) 3051S

    B) 848T

  • What device is ideal for a customer who wants the What device is ideal for a customer who wants the most basic of temperature measurements?most basic of temperature measurements?

    A) 3144P

    B) 248

    D) 644

    C) 144

  • SummarySummarySummary

    This section has helped you:

    Understand how a transmitter works

    Understand the advantages of using a transmitter over wiring direct

    Understand the key features and benefits of the Rosemount 144, 248, 848T, 644, 648, and 3144P temperature transmitters