    MIC Microbiologically induced corrosion

    in cold systems at Forsmark NPP

    FOP 7-9 april 2019, Västerås

    Massimo Cocco – FKA Material Analysis

    Pär Blombergsson – FKA In Service Inspection

    1

  • © Forsmarks Kraftgrupp AB

    The utilization of Fe(II) as an electron donor makes iron oxidizing bacteria to strong analog organisms for any potential life that could be found on Mars.

    2

  • © Forsmarks Kraftgrupp AB

    MIC: an underestimated degradation mechanism

    • 20% of all corrosion damage is estimated to be caused by MIC • Yet the degradation mechanism has officially been recognised only

    recently (NACE, 1990) • MIC differs från other types of local corrosion damage in terms of attack

    patterns, propagation, degradation speed, effects on mechanical integrity, counteractions and recidivity

    • Lack of systematic characterization of different MIC-phenomena makes it difficult to predict damage tollerance of mechanical components in specific cases

    • Improved characterization and understanding of MIC-phenomena is directly relevant to the optimization of the maintenance program at FKA

    3

  • © Forsmarks Kraftgrupp AB

    MIC in the cooling water system for the turbin

    4

    Voluminous tubercles, but minimal amount of material degradation. The tubercles developes in shelted places, on painted carbon steel. The distribution pattern on equivalent places appear to be random, although there is a tendency for the tubercles to develope in colonies

  • © Forsmarks Kraftgrupp AB

    Soft, well defined forms

    5

    A thin outer layer covers the tubercles. On the inside the body is spongelike, soft and friable. If powdered it shows an intensive yellow ochre color. This type of MIC bacteria metabolize probably both organic matter and iron ions. The rate of material degradation is so low that it is not expected to affect the mechanical integrity of the components under their designed life time.

  • © Forsmarks Kraftgrupp AB

    At a closer look many other interesting features are disclosed

    6

  • © Forsmarks Kraftgrupp AB

    MIC displays different habits on different materials

    7

    On the flat surfaces of super duplex cast steel are found small, individual tubercles with hard shell and spongelike core which is partially green colored. They do not cause any significant level of material degradation

    Element Wt% Wt%

    Sigma C 6,08 0,79 O 32,82 0,89 Si 0,7 0,11 S 4,75 0,62 Cl 0,82 0,17 Cr 37,64 1,12

    Mo 17,19 1,52 Total: 100

  • © Forsmarks Kraftgrupp AB

    A third type of tubercles

    8

    Within the shelted gaps between the flanges inside the pump house are found well shaped tubercles with well defined canals for exchange between the inside and the outside environment. The base material is painted carbon steel.

  • © Forsmarks Kraftgrupp AB

    Well defined features

    9

    The tubercles display some remarcably regular features. The inside is hollow, with walls that in some parts display uniform thickness, which appear to be defined by a dark, smooth and perfectly adherent film.

  • © Forsmarks Kraftgrupp AB

    Canals and growth directions

    10

    Orifices appear on the top of the inside dome. The spongelike core has distinct growth directions. Different structural levels can be identified by different color nuances.

  • © Forsmarks Kraftgrupp AB

    MIC in the fire protection system

    11

    A more aggressive type of MIC is encountered in the open tanks of the fire protection system. Here we find distinct, big tubercles which appear to be randomly distributed, although preferentially on shelted places. The form of the tubercles is often elongated, like big slugs, and can protude well beyond the solid support on which they stand. The base material is painted carbon steel. The environment is industrial water.

  • © Forsmarks Kraftgrupp AB

    Protuding tubercles

    12

    The tubercles may develop and protude well beyond the metal surface from which they assume their building material. The feature is suggestive of an advanced transport system supporting the metabolism of the tubercles.

  • © Forsmarks Kraftgrupp AB

    Deposits of black and soft iron(II)-compounds

    13

    The degradation of the base material is concentrated on a limited spot under the body of the tubercle. The material damage is significant. At the bottom of the corrosion holes are found deposits of black and soft iron(II)-compounds.The size of the corrosion holes appear to be related to how big the tubercles are. The dark holes are probably colonized by sulphur reducing bacteria, SRB, which ”dig out” iron(II) ions from the base material. Those ions are then metabolized by the iron oxidizing bacteria which build up the red body of the tubercles.

  • © Forsmarks Kraftgrupp AB

    A big hanging ”slug” digged a deep corrosion hole

    14

    This remarcably clinging specimen has digged a 5mm deep hole on top of its support

  • © Forsmarks Kraftgrupp AB

    Some solitary specimens

    15

    A big, elongated tubercle in a solitary position far away on a pipe wall. And a small tubercle on a screw head

  • © Forsmarks Kraftgrupp AB

    Complex structure

    16

    An ordered pattern of thin magnetite walls builds up a complex system of adjacent cells

  • © Forsmarks Kraftgrupp AB

    Biogenerated iron(III)oxide-structures

    17

    In the scanning electron microscope the biogenerated features of the corrosion tubercles are displayed in an astonishing richness of details

  • © Forsmarks Kraftgrupp AB

    Hollow microtubes

    18

    The spongelike core material of the tubercles is build up by an intricate network of hollow microtubes. Iron(III)-oxide is crystallised radially around the bacteria in the process building up the microtubes

  • © Forsmarks Kraftgrupp AB

    Biomineralization

    19

    The iron oxidizing bacteria take up the energy contained in the metal and return it to a mineral compound

  • © Forsmarks Kraftgrupp AB

    Life is way of sustaining energy dissipation

    20

    By buildning up complex solid structures the bacteria obtain a selfsustaining dynamic system which optimize the flow of metabolites and maximize the energy uptake from the base material. That’s way MIC may results in substantially higher degradation rates as compared to trivial cases of pure electrochemical corrosion.

    LIFE IS AN ORDERED WAY OF PRODUCING DISORDER

  • © Forsmarks Kraftgrupp AB

    Different features - different functionality

    21

    In same regions the microtubes are equipped with small plates

  • © Forsmarks Kraftgrupp AB

    Iron oxidizing bacteria

    22

    The pictures below catch a bacteria emerging from in between a group of plates

  • © Forsmarks Kraftgrupp AB

    Bacteria

    23

    Bacteria elongating from in between a group of plates on a microtube to the microtube next by. What’s going on?

  • © Forsmarks Kraftgrupp AB

    Further features yet to be understood

    24

    Deep buried into a system of merging hollows is observed a porous structure. The richness of features observed gives clues to a complex biological system yet to be understood

  • © Forsmarks Kraftgrupp AB

    MIC diagnosis

    25

    The twisted shape of the bacteria catched in the right picture suggests that it may belong to the iron oxidizing species Gallionella Ferruginea

  • © Forsmarks Kraftgrupp AB

    Some summarizing remarks

    26

    • MIC-tubercles display a high level of structural organization, as compared to the simple model used to describe tubercle formation by pure electrochemical theory.

    • A richness of morphological features calls for better characterization and understanding

    • Diagnosys, damage prediction and proper countermeasures may be much improved by learning more about the phenomena.

    Electrochemical model for corrosion tubercle

  • © Forsmarks Kraftgrupp AB

    Engineering challenges

    27

    In order to be able to predict the impact of MIC on the systems we need to be able to quantify the extent of MIC-damage in a rational and reproducible way In the coming years Forsmark will carry out both extensive inspections of the fire protection system and discrete sampling for in depth charachterization Inspection systems need to be able to:

    • identify the degradation mechanism • quantify parameters related to the number and size of both the tubercles and

    the max deptht of the corrosion holes .

  • © Forsmarks Kraftgrupp AB

    The pressurized part of the fire protection system

    28

    Out in the tube system the water pressure rises to 20 bar and the oxygen level becomes much lower then in the open tanks. The base material is galvanised steel. Here the MIC tubercles take on a different habit: they are relatively small and homogeneous in some of their size parameters. They have hard shells and hard cores.The depth of the corrosion holes appear to be related to the hight of the tubercles.The corrosion rate appear to be constant and relatively slow..

  • © Forsmarks Kraftgrupp AB

    Thick shell and hard spongy core

    29

    Evidence for MIC is given by the spongy appearance of the core material of the tubercles. At higher magnification the biogenerated microtubes are clearly identified, although the picture on the ringht gives the impression of higher density and sharper angles than expected.

  • © Forsmarks Kraftgrupp AB

    Advanced state of crystallization

    30

    At even higher magnification the microtubes look kind of fossilized.The originally biogenic Fe(III) Oxide-structures appear to have undergone a further process of mineralization.

  • © Forsmarks Kraftgrupp AB

    Inspection methods

    The fire protection systems at Forsmark are quite extensive. Which inspection methods are suited to give us a the real picture of the system’s status? • Visual • UT • RT

    31

  • © Forsmarks Kraftgrupp AB

    Galvanized pipe DN 50

    32

    • Detection • Characterization • Sizing

  • © Forsmarks Kraftgrupp AB

    Visual • It requires opening of the

    systems • Fireprotection system not in

    operation

    33

  • © Forsmarks Kraftgrupp AB

    Digital x-ray • Screen size ca 500mm • Voltage up to 300kv • Online evaluation • Conventional x-ray

    equipment • Need safety zone • Ca 50-100 pictures in 8

    hours

    34

  • © Forsmarks Kraftgrupp AB

    Mechanised ultrasonic Testing

    • Loss of bottom eco due to scanning • The problem could eventually be

    solved by using focused probe • Small pipe diameters and thin pipe

    walls limit the applicability of UT

    35

  • © Forsmarks Kraftgrupp AB

    Summery

    36

    Mechanised ultrasonic testing • It finds the defects • It is difficult to identify the degradation

    mechanism Digital x-ray • It finds the defects • It is possible to identify the degradation

    mechanism • Quantitative measurements are possible Visual inspection • It requires opening of the systems • It clearly identifies the degradation

    mechanism • Needs open system

  • © Forsmarks Kraftgrupp AB

    Real case 2019 • Pipe diameter

    150mm to 200mm • Waterfilled

    37

  • © Forsmarks Kraftgrupp AB

    Real case 2019

    38

  • © Forsmarks Kraftgrupp AB

    Real case 2019

    39

  • © Forsmarks Kraftgrupp AB

    Real case 2019

    40

  • © Forsmarks Kraftgrupp AB

    Energy for life

    41