8/2/02 Michelle Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 1 Michelle Jenkins, Mechanical Engineer

Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

1

Michelle Jenkins, Mechanical Engineer

Page 2: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

2

• Modules and bins common to vertex room and CEB

• CEB racks are standard 19” equipment racks

• Vertex room racks are VLA B-Racks

Page 3: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

3

• Plascore® honeycomb panels used for RFI shielding

Page 4: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

4

• Reusing VLA bins

Page 5: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

5

• Building on AT design using VLA Dimensions

• Extrusions & panels utilizing RFI gasketing

Page 6: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

6

• Same design with heatsink

• Requires the same bin space as a double wide

Page 7: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

7

Page 8: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

8

• Designed to house synthesizer

• Optional center panel for multiple layer component mounting

Page 9: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

9

• Provisions for heatsinking Yigoscillator with hole through module for airflow over heatsink

• Heatsink gasketed to provide RFI seal

Page 10: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

10

Page 11: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

11

Michelle Jenkins, Mechanical Engineer

Page 12: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

12

• Completely new design– Integrates digitizer, samplers, and IF DTS into

single package– Designed specifically to address RFI and

Thermal Issues

Page 13: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

13

• Panels 100% welded to frame – Vibration stability – RFI

• Plexiglas door to protect fiber connections

• Dimensions– 32”H x 30”W x 26”D

Page 14: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

14

• Gasketed filters– UAF with internal

foam barrier– SpiraTM honeycomb

• Rack sits on base for air flow reasons

• All fiber runs to fiber mux inside the rack

Page 15: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

15

• Follows design of VLA bin

• Gasketed faceplate added for RFI seal

• Dimensions– Faceplate 11.25”H x

26.6”W x .125”D

– Body 11”H x 25”W x 20.25”D

Page 16: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

16

• Solid outer case – RFI sealed

– SpiraTM filters

• All connections on module front panel

• Dimensions– 10.46”H x 6.17”W x

~19.95”D

Page 17: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

17

• Slides in/out of solid case

• Center plate provides module stability

• Heat-producing components mounted to center plate

• PCBs connected by internal backplane

• Stand-offs provided to support module on bench during maintenance

Page 18: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

18

• Welded single-piece construction

• VLA guide blocks

• Gasketed filters mounted top & bottom

Page 19: Michelle Jenkins, Mechanical Engineer · Jenkins EVLA Rack/Bin/Module PDR 17 June 2002 2 • Modules and bins common to vertex room and CEB • CEB racks are standard 19” equipment

8/2/02 Michelle Jenkins

EVLA Rack/Bin/Module PDR17 June 2002

19