4
Compact wall hung gas boilers METROPOLIS DGT

Metropolis DGT Opt

Embed Size (px)

DESCRIPTION

Gas Boiler Specifications

Citation preview

  • Compact wall hung

    gas boilers

    METROPOLISDGT

  • METROPOLIS DGT

    The small from the great performances

    The Metropolis DGT is Simes very latest compactwall hung gas boiler for central heating and theD.H.W. production, ideal for whom looks and greatperformances but in a small space are important. In particular, the compact dimensions allow easyfitting into kitchen furniture, as well as easymaintenance in the narrowest spaces.

    The high technical specifications, the elegantdesign and the facility of use assure the best ofSimes quality for the modern installations. Metropolis DGT comply with the EuropeanDirectives Gas EEC 90/396, ElectromagneticCompatibility 2004/108/CE, Low Tension2006/95/CE and Efficiency EEC 92/42.

    Wall hung boilers

  • 4 71

    2 8

    3

    5

    The compact dimensions of Metropolis DGT(depth reduced of 5 cm compared to the previousmodel) mean it can easily fit into a kitchencupboard and be serviced even in restricted spaces.Bithermal heat exchanger definitely reduces thedeposits on sanitary equipment, removes unreliablecritical components (spiral heat exchanger andswitch valve) and allows an easy layout in the boiler.Moreover, it helps the access and guarantees asimple maintainability.The flowmeter on the sanitary side allows tomaintain the temperature.

    Metropolis DGT is a high performance boiler.It comes equipped with an automatic pilotlight ionisation ignition, electronic circuitboard to continuously vary the heating andproduction of hot water, and anti-freezesystem which activates at 6C via an NTCsensor. If coupled with the external probe, it can adjust thetemperature, reducing the working costs of theheating plant.

    All versions, equipped with a special kit, perfectlymatch a heating system with solar arrays.The solar kit is composed by a thermostatic mixervalve and by a temperature controller probe NTC. Itcompares the sanitary water temperature comingfrom solar storage, with the one laid on the sanitarypotentiometer.The boiler starts only if the temperature of the solarboiler is lower than the temperature laid in theboiler.

    Metropolis DGT control board is both functionaland technological. For the first time, Sime adoptscapacitive keys, that is to say, electric devices, able torecognize a nearby finger.Moving mechanical parts are so removed and the

    panel is watertight (the boiler has actually reachedthe protection level IPX5D). Easy and intuitivecontrols really simplify the usage, the LCD displayand coloured leds immediately show the maininformation and possible working defects.

    List of functions/instruments

    LCD display

    Red led: boiler in allarm

    Green led: ok key

    Function selector (on, off, summer,winter, boiler reset)

    D.H.W. temperature control

    C.H. temperature control

    Change parameters

    Installer menu parameters shift

    1

    2

    3

    4

    5

    6

    7

    8

    Functional and technological

    Simply and reliable

    Highly concentrated performance

    6

  • 70

    10

    29,55039

    70 70 70 ==

    GMR E U

    79

    2

    L

    75

    08

    5

    6

    0/

    100

    K120

    188

    188

    8

    0

    8

    0

    125

    125

    290

    60100

    122

    G

    D

    Technical features

    Dimensional details - Hydraulic connections

    Dimensions

    Connections

    Technical features and safety devices

    Circulating pump with c/w air separatorBithermal heat exchangerDifferential pressure switch guaranteeing functioningof the flueing system3 bar safety valveAutomatic/manual by-pass on the C.H. circuitChimney sweep function allowing an easy maintenane andcombustion analisys operationsWater pressure switchFlowmeterSmokes statMatchable with remote control CR63 e CR73

    M C.H. flow 3/4R C.H. return 3/4G Gas connection 3/4E D.H.W. inlet 1/2U D.H.W. outlet 1/2

    25 OF 450 - 13025 BF 400 203 -30 BF 450 221 -

    OFL mm K mm D mm BFco

    d. 3

    951

    00

    0 -

    07

    /2

    00

    9

    We pursue a policy of continuing improvement in design and performance of our products. The right is therefore reserved to vary specifications without notice.

    Fonderie Sime S.p.A Via Garbo, 27 37045 Legnago (Vr) Italy Tel. +39 0442 631111 Fax +39 0442 631291 www.sime.it

    25 OF 25 BF 30 BFHeat outputNominal kW (kcal/h) 22,8 (19.600) 23,7 (20.400) 28,0 (24.000)Minimum kW (kcal/h) 8,5 (7.300) 7,5 (6.450) 9,0 (7.750)Heat input nominal kW 25,0 25,5 30,0Efficiency rating at nominal heat input % 91,3 93,0 93,3Efficiency rating at 30% of nominal heat input % 89,9 92,0 92,0Energy efficiency (EEC Directive 92/42) Water content litres 1,0 1,0 1,0Maximum water head bar 3 3 3Electrical power consumption W 85 110 115Electrical protection grade IPX4D IPX5D IPX5DExpansion vessel water content litres 6 6 6Expansion vessel preloading pressure bar 1,2 1,2 1,2Specific D.H.W. flow rate (EN 625) litres/min 10,9 11,3 13,0Continuous D.H.W. flow rate t 30C litres/min 10,9 11,3 13,4Minimum D.H.W. flow rate litres/min 2,0 2,0 2,0Minimum/Maximum D.H.W. pressure bar 0,2/7 0,2/7 0,2/7C.H. setting range C 4080 4080 4080D.H.W. setting range C 3060 3060 3060Max. horizontal lenght of coaxial flue duct 60/100 m - 3,5 3,0Max. horizontal lenght of coaxial flue duct 80/125 m - 6 6Max. horizontal lenght of twin flue ducts m - 15+15 12+12Weight kg 26 30 31

    Open combustion chamber Sealed combustion chamber

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice