40
ELEQ ® develops, produces and markets FAGET ® and KWK ® Metering Protection Lighting Light-mast sets Connection boxes for public lighting Quick and safe installation Wall-mounted solutions Special applications Public Lighting Management System

Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

Embed Size (px)

Citation preview

Page 1: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

ELEQ® develops, produces and markets FAGET® and KWK®

Metering

Protection

Lighting

Light-mast sets

Connection boxes for public lighting

Quick and safe installation

Wall-mounted solutions

Special applications

Public Lighting Management System

Page 2: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You
Page 3: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

1

Standard junction boxesTechnical information on light-mast sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5L5103 LS-74 1xE14 very small . . . . . . . . . . . . . . . . . . . . . . . . 9

5L1001 LS-84 1xE14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

5L1101 LS-84 2xE14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

5L1201 LS-84 3xE14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

5L4141-S LS-84 1xE14 Class 2 with phase switching . .13

5L4143 LS-84 3xE14 Class 2 . . . . . . . . . . . . . . . . . . . . . . . . . .14

5L8214 LS-100 2xE14 Class 2 IP55/IK10 . . . . . . . . . . . . .15

5L3252 LS-84 3xfuse 10x38mm . . . . . . . . . . . . . . . . . . . . . . .16

5L8010 LS-100 3xfuse 10x38mm . . . . . . . . . . . . . . . . . . . . . . .17

5L2001 LS-94EN 1xE27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

5L2101 LS-94L 2xE27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

5L2009 LS-94S1/10 1xE27 with phase switching. . . . . . . . . . .20

5L0403 LS-104S3/16 3xE27 with phase switching. . . . . . . . . . .21

Wall-mounted junction boxes5L8214 Junction box for wall-mounting IP55/IK10. . . . . . . . . . . . . . . . . . . .18

2RVS30 Stainless steel pillar box for LS-94. . . . . . . . . . . . . . . . . . . . . . . . . . . .22

2RVS50 Stainless steel wall-mounting box for LS-94 . . . . . . . . . . . . . . . . . . .23

2RVS60 Extended stainless steel pillar box for LS-94 . . . . . . . . . . . . . . . . .24

Special applications5L6002 Junction box with relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

5L6003 LS-94 provided with DIN-rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

5L6009 Junction box for video monitoring camera (CCTV) . . . . . . . . . . . .27

5L8005-H Junction box with circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

5L8012 LS-100 provided with DIN-rail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

5L8014 Junction box with earth leakage circuit breaker . . . . . . . . . . . . . .30

5L6051 Junction box for Philips OLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

5L6030 Junction box with for traffic masts. . . . . . . . . . . . . . . . . . . . . . . . . . . .32

5L8021 Junction box with earth leakage circuit breaker and socket. . .33

AccessoriesFuses, suspension brackets, screening caps, etc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

Table of contents

General informationOur company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

ISO 9001/14001 and RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

ELEQ and the Internet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Street Lighting Management SystemsStreet Lighting Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SMS ‘lighting on’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Page 4: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

2

ELEQ, the concentration of strength of KWK and FAGET

The company FAGET, founded in 1946, took over the German company KWK in 2003. This concentration of strength allows us to serve the European market better. We do this under the name ELEQ, with the FAGET and KWK brands.Our product programme comprises a broad range of current transformers, transducers, meters and light-mast junction boxes. Quality products that find their way to electricity companies, industry and technical wholesalers, etc.

MeteringProducts for metering purposes andenergy management for energy companies, marine and industry.

LightingJunction boxes and software for the management of street lighting.

ProtectionCurrent and voltage transformersystems for manufacturers of power transformers, high-power switches and generator builders.

A new name for a trusted companyThe name ELEQ stands for a new élan, and certainly also for trusted values. Our well-known brands FAGET and KWK will be kept and linked to our broad programme of products and services. And our way of working will also remain unchanged: efficient, customer-oriented and reliable.

We serve the market from three strategic product-market combinations

Our factory in Steenwijk (NL) Eleq Steenwijk (NL) and Eleq Kerpen (D)

This catalogue gives you an overview of the products and systems in our Lighting product-market combination.

Page 5: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

3

New digital catalogue of Light-mast setsELEQ has all its light-mast sets and wall-mounting junction boxes available in digital form. Our Internet site has one sheet with all technical specifications and a clear 3-D colour sketch per product. You can download the most widely-used products as PDF files, so that you easily add them to manuals or specifications.Besides the standard junction boxes, you can also find junction boxes for specific situations such as wall-mounted solutions, traffic lighting, CCTV, bus shelters, car park ticket machines or the new junction box for the Philips OLC, for example.If you miss any products or have any ideas to improve the site, please send us an e-mail.For more information, look at www.eleq.com.

ISO 9001, ISO 14001 and RoHS

ISO 9001 – ELEQ has been working in accordance with ISO standards since 1993. At both establishments, we develop, produce and sell in accordance with the new ISO 9001:2000 guideline and are certified by the KEMA.

ISO 14001 – ELEQ’s basic philosophy is to meet the most stringent environmental legislation. Therefore, ELEQ develops, produces and sells in accordance with the new environmental care system EN ISO 14001:2004 and is certified by TÜV. We are constantly reviewing all processes to minimise the use of toxic substances.

RoHS – As of 1 July 2006, the RoHS guideline forbids the sale of new electrical and electronic equipment in Europe that contains more than the maximum permissible quantity of lead, cadmium and mercury, etc. All our light-mast sets meet this guideline.You can find a declaration and more information on our Internet page www.eleq.com.

KEMA approval, your guarantee of quality

The FAGET light-mast sets have been tested by the KEMA and have been awarded KEMA approval.This means that the design and manufacture of the junction boxes meets the KEMA requirements. Checks are carried out at regular intervals. A copy of the certificates can be obtained on request.

Research and developmentThe models presented in this brochure are the fruit of many years of re-search. As a logical consequence of ELEQ’s market-oriented approach, these basic versions can be adapted to other specifications on request. Naturally, the junction boxes can be supplied completely assembled with a variety of accessories. With our modern 3-D development tools, we can quickly make proposals for tailor-made solutions.

Page 6: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

4

Street Lighting Management System

Together with the company DigiTel, ELEQ has developed a program for the management of street lighting. Not only is all data of your light masts easily accessed, the maintenance, replacement calculation or data mutation is also child’s

play. The database has an open structure and can be linked to other software packages if desired. This program is characterised by excellent user-friendliness and independence. Much attention has been paid to data entry and malfunction handling, plus mutating and selecting groups of data. In addition, the data can be approached in different ways with cross-reference tables and reports. The feeding points can also be clearly defined and managed. All relevant data on masts, fittings, lamps and feeding points are shown in one screen per mast. Your whole street lighting file can be accessed with just a few clicks on the mouse.Moreover, authorities and own settings can be defined per user. Obviously, photographs of armatures, masts and any feeding points can be added. The keyword is user-friendliness.

Layer modelThe program has three layers, i.e.: the basic package, the graphics link and remote switching. You start with the basic package and determine if and when you want to expand it.

The basic package (layer 1)The basic package is the heart of the program. It contains all master data, masts and feeding points. All geographical information, such as the layout in boroughs, streets and road surfaces and, if known, the X- and Y-coordinates.The functionality in the basic package is sufficient for a street lighting manager to perform his daily work. Examples of this are: entering malfunctions, replacement calculation, planning maintenance, entering new masts, entering mutations, making analyses or

calculating budgets required. Your existing files, for example in Excel, can be converted to our system.

The graphics link (layer 2)When the basic package is properly set up, a link can be made to your existing graphics environment. Here, selections can be displayed on a graphics card. With a selection on the card, the underlying data can also be retrieved. With a graphics extension module, the program can communicate with your existing graphics environment, such as Microstation, Autocad or Nedgraphics.

remote switching

graphic link

base

Page 7: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

5

Remote switching (layer 3)As user, the need can arise to switch the street lighting on or off remotely. Examples of this are event terrains and entertainment centres, etc. In this case, you can connect your hardware with the OVMS package. Now, you have an integral street lighting management and you only have one place where the information is kept up to date.

MalfunctionsWith this package, you can select by whom you want to have the malfunctions entered and by whom you want to have them handled (yourself or the contractor). The manager can see the average time that a malfunction is open.The contractor can print a malfunction note himself that contains all relevant data for him. You can also easily make an extensive analysis into the cause of the malfunction, such as the number of vandalism cases or car crashes in a borough or street.

MaintenanceWith the maintenance wizard, you can plan all work, such as replacement and regular maintenance. The costs of maintenance per borough, per period or per type of maintenance can also be easily calculated. You can immediately export all this data to Excel. The module for adding new masts ensures standardisation in your file. You select by entering basic configurations of masts, lamps and fittings.

Cross-reference tablesThese allow you to make fast and efficient relationships. Horizontally and vertically, you can make numerous combinations, such as: which lamps are in which street and how many? What is the age distribution of my masts? You literally have the answer with ‘one push on the button’. Then, with a second press, the data can be exported to Excel.

ReportsYou can print all sorts of reports with data that you consider important. By using an extensive filter, you can make multiple selections. One example can be: “All masts larger than 4 metres in the centre with a certain armature and installed before 1970”.A total of 20 standard reports are defined.

ExtrasTogether with our customers, we have also developed extra modules, such as: Standard figures, access through the web, road signs, barcode, links to other software packages or disciplines such as road management. For extensive and up to date advice or a demonstration, we advise you to contact our sales department.

malfunction wizard

replacement scedule

Malfunction report

Page 8: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

6

SMS ‘lighting on’switching (street) lighting with the mobile telephone.

ELEQ supplies a module, with which (street) lighting can easily be switched on or off with an SMS message. The sta-tus of the lighting can be called up and the burning hours are registered. In addition, it is possible to report malfunc-tions on the lighting installation by SMS to technicians on duty.Afterwards, you can establish exactly when the lighting went on or off and when a malfunction occurred or was cleared. This can be important in connection with the liability of the manager.

SafetyEven when the external power is absent, the data is stored by the internal clock and power supply. The unit can operate fully autonomously. Further-more, third parties cannot access the module by SMS. The unit knows from which telephone numbers it may accept commands. If desired, this can also be combined with a password.

Street lighting in a municipalityThis system makes it possible to switch power supply boxes for the street lighting at places where there is no TF signal available. Here, the system is built into the existing street lighting box and can operate autonomously. All units together can communicate with a central system. From this system, new commands can be given for all or for a part of the units.Besides this, it is possible to intervene in the different switching patterns and to get information about malfunctions, burning hours and consumptions.

Advertising pillar A10/A2:At a highly-visible location on the ring road near Amsterdam, the lighting fittings on a 43 m high advertising pillar are constantly monitored. Malfunctions are automatically reported by SMS and the system immediately connects a spare lamp. Moreover, it is possible to call up the status and the number of burning hours.

Harbours and industrial estatesIn harbours, there is often lots of light, usually at places where it is not immediately necessary. With this system, the lighting is managed on four loading and unloading quays in Harlingen. The lighting spots on these quays can be operated per quay with a simple SMS command.

Calamity lighting on market squaresBecause of the widening of the opening times for bars, hotels and catering in the entertainment centre, the police want to have the possibility of switching the lighting on by gsm when incidents occur. The lighting can also be switched off with an SMS message.For more information, contact our sales team or send an e-mail to [email protected].

Page 9: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

7

Technical information on light-mast sets

From back to frontNo matter how you look at it, our junction box is immediately recognisable. The base of the junction box is made of weather-resistant, glass-fibre reinforced, top quality plastic. A much more important aspect is that the touch-safe, closed housing is drip-proof, while the inside screening cap ensures that it is touch-safe when open. Anyone with practical experience can vouch for this. The transparent cap of indestructible polycarbonate is provided with a non-detachable single-screw fastening. The fact that all metal parts are made of corrosion-free (nickel-plated) brass emphasises the price-quality ratio.

Connection without further adoTerminal strips are essential for the functioning of light-mast junction boxes. To make things easy for you, ELEQ has fitted terminal strips between the terminals and the fuses, so that the junction box can be connected without any further ado.

Minimum inside diameter of the light mastIt goes without saying that there is only a very limited space for a junction box in a light mast.Junction boxes for light-mast sets are so compact that they unerringly fit in the tight space available. The minimum inside diameter that the light mast must meet is indicated on the product sheets. For example, an LS-94 fits in a mast with an inside diameter of 94 mm.

Pull reliefThe standard pull relief is suitable for two light-mast cords and two ground cables.There is also a version for three underground cables (5L9978). Ground cables with a diameter of 13 to 23 mm can be safely clamped with the spacers supplied. On request, the junction box can be fitted with a pull relief for three cables. This pull relief is made of stainless steel and can be ordered separately.

Degree of protectionAll our junction boxes are made of high-grade plastics. Where the plastic junction boxes are installed against a wall or on the outside of a mast, the junction boxes are a minimum of IK10 and IP55. The stan-dard LS-100 is provided with double isolation (class 2) and has an IP55 degree of protection.

Excellent ventilationThe inventive design of the junction box also makes adequate provision for the ca-bling method. The open cable inlet in the bottom ensures excellent ventilation inside the box. A deliberate decision was made to locate a cable inlet in the bottom, so that condensed moisture cannot collect. This also prevents soaking along the cables.

Touch-safe screening capsFor extra safety on the mantle terminals, plastic caps can be supplied, which make the terminals touch-safe.

Page 10: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

8

Different fusesBesides versions with E27 (DII) fuses, the range of junction boxes for light masts also includes a number of models with tube (10x38mm) or E14 (D01) fuses for different amperages. The standard junction boxes are mostly supplied without fuses; however, we can supply or fit them.

Suspension bracketsIf desired, a stainless steel suspension bracket can be supplied. This bracket can have one or two slotted holes. This makes it possible to hang the junction box lower or, if there is no sliding rail, to hook the box behind the assembly strip (5L9301).

LS-84/94/104 with phase switchingThis type of light-mast set has a phase switch and is suitable for street lighting networks with a maximum of three phases, neutral and earth. Three descending groups are possible, which are each secured separately. The switch can be used to connect each descending group to another core without removing the cables. The LS-84S1 and the LS-104S2 and S3 are mechanically secured against short circuiting between the phases.The LS-84S1 has one fuse; the switchable LS-104 has two or three fuses.

Earth-neutral connectionIf a fixed earth-neutral connection is desired, the box can be supplied with a brass nickel-plated connection strip fitted in it. The strips can also be obtained separately and fit all LS-94 models.

Automatic earthingThe earth clamp is connected to the fixture point in the light mast by the sleeve, so that it is automatically earthed without further provisions.An extra (second) earth connection is present in the bottom of the box.

Product sheetsOn the following pages, you can find a selection of light-mast sets, wall-mounting junction boxes and accessories.These sheets can also be found on our website. If you cannot find the solution for your problem, contact our sales team.

fuse 5x 25mm fuse 10x 38mmfuse E27fusecap E27 fuse E14

Page 11: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

9

LS-74 5L5103

Page 12: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

10

LS-845L1001

Page 13: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

11

LS-845L1101

Page 14: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

12

LS-84 5L1201

Page 15: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

13

LS-845L4141-S

Page 16: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

14

LS-84 5L4143

Page 17: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

15

LS-100 5L8214

Page 18: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

16

LS-945L3252

Page 19: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

17

LS-100 5L8010

Page 20: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

18

LS-94 5L2001

Page 21: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

19

LS-945L2101

Page 22: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

20

LS-94S1/10 5L2009

Page 23: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

21

LS-104S3/16 5L0403

Page 24: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

22

Stainless steel pillar box 2RVS30

Page 25: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

23

Stainless steel wall-mounting box for LS-94 2RVS50

Page 26: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

24

Extended stainless steel pillar box for LS-94 2RVS60

Page 27: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

25

Junction box with relay5L6002

Page 28: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

26

LS-94 provided with DIN rail 5L6003

Page 29: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

27

Junction box for video monitoring camera (CCTV) 5L6009

Page 30: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

28

Junction box with circuit breaker 5L8005-H

Page 31: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

29

LS-100 provided with DIN rail 5L8012

Page 32: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

30

Junction box with earth leakage circuit breaker 5L8014

Page 33: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

31

Junction box for Philips OLC 5L6051

Page 34: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

32

Junction box for traffic masts 5L6030

Page 35: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

33

LS-100 5L8021

Page 36: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

34

Bracket incl. M6 boldArticle nr. 5L9301Packing: 10 pieces

3-cable pull reliefArticle nr. 5L9978Packing: 10 pieces

Cover LS-100 type 1Article nr. 5L9971Packing: 1 piece

Triangle key for LS-100Article nr. 5L9960Packing: 1 piece

BracketArticle nr. 5L9302Packing: 10 pieces

Cover LS-100 type 2Article nr. 5L9972Packing: 1 piece

Triangle key for stainless steel boxesArticle nr. 5L9961Packing: 1 piece

Cover LS-100 2x27mmArticle nr. 5L9970Packing: 1 piece

Light-mast sets

Accessoires

ELEQ b.v.ELEQ b.v.Tukseweg 1308331 LH SteenwijkThe Netherlands T: +31 (0) 521 533 333T: +31 (0) 521 533 391www.eleq.com

Page 37: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

35

Slide nut for TS32-railArticle nr. 5L9658Packing: 100 sets

Pull relief Bottom: Article nr. 5L9040Top: Article nr. 5L9041Packing: 10 pieces

Bracket LS-84/LS74Article nr. 5L9002Packing: 10 pieces

Screw M6 x 16 brassArticle nr. 81985Packing: 1000 pieces

Bending tool16mm²: Article nr. 5L995025mm²: Article nr. 5L9951Packing: 1 piece

Screening caps 10mm²: Article nr. 523979 16mm²: Article nr. 7042025mm²: Article nr. 71441Packing: 100 pieces

RelayArticle nr. 80969Packing: 10 pieces

Plate for covering fuse holder E27Article nr. 71861Packing: 100 pieces

Earth neutral connection 10mm2

Article nr. 70328Packing: 100 pieces

2xyour logo

ELEQ b.v.ELEQ b.v.Tukseweg 1308331 LH SteenwijkThe Netherlands T: +31 (0) 521 533 333T: +31 (0) 521 533 391www.eleq.com

Page 38: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

36

Fuse cap E14 (D01)Article nr. 80387Packing: 10 pieces

Fuse cap E27 (DII)Article nr. 10244Packing: 10 pieces

Fuse E27 (DII)2A: Article nr. 064764A: Article nr. 102436A: Article nr. 16263Packing: 10 pieces

Fuse E14 (D01)6A: Article nr. 8038410A: Article nr. 80385Packing: 10 pieces

Adaptor ring E27 (DII)2A: Article nr. 169654A: Article nr. 102426A: Article nr. 16264Packing: 10 pieces

Adaptor ring E14 (D01)6A: Article nr. 8038810A: Article nr. 80389Packing: 10 pieces

Fuse 5x 25mm 2A: Article nr. 52356.24A: Article nr. 52356.46,3A: Article nr. 52356.6,3Packing: 10 pieces

Fuse cap Article nr. 52358Packing: 10 pieces

Fuse 10x 38mm2A: Article nr. 815594A: Article nr. 815606A: Article nr. 81722Packing: 10 pieces

This cataloque has been put together with the utmost

care. In spite of that, it can not be prevented that

drawings and text containe mistakes. If that is the case

we apologise for it. If you will find a mistake we kindly

ask you to contact us so we can update the sheets on

our website.

Fuses

Page 39: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You
Page 40: Metering Protection Lighting - injab BR Light-mast sets EN.pdf · Metering Protection Lighting ... new environmental care system EN ISO 14001:2004 and is certified by TÜV. ... You

Mastering Electricity

ELEQ b.v.

P.O. Box 128330 AA SteenwijkThe Netherlands Tukseweg 1308331 LH SteenwijkT: +31 (0) 521 533 333F: +31 (0) 521 533 398

Siemensstraße 150170 Kerpen-SindorfGermanyT: +49 (0) 2273 98 870F: +49 (0) 2273 51 951

E: [email protected]: www.eleq.com

LS092006EN