2
Mercaptans are organosulfur compounds often found in unrefined or partially refined hydrocarbon feedstocks. They contain several undesirable qualities, including strong odor, corrosivity, and degradation of downstream additives and hydrocarbon end products. A catalytic process is utilized to remove mercaptans for these reasons. Challenges to pH processes exist in both extraction and sweetening Merox processes, including reference fouling, coating, and abrasion. Challenges Reference electrolyte can be poisoned by ex- cess caustic, mercaptans, disulfides and other contaminants. Coating and plugging of porous reference junction by residual oils. Abrasion of pH measuring membrane due to suspended catalyst fines. Merox - Mercaptan Removal (pH/ORP) Specifications If the process is isolated, an in-line electrode such as the Y-410B-F6 or V-19DB-F6 Series is recommended. If the process is not isolated, a retractable such as the MK7 or Live Tap model is recommended. For more information, contact your AlpHa/Van London Co. representative or distributor. pH Range 0-14 0-14 0-14 Temperature Range 0-130ºC 0-130ºC 0-130ºC Pressure Range 0-150 PSI @ 25ºC Body material Ryton Kynar Stainless Steel

Merox - Mercaptan Removal (pH/ORP)

  • Upload
    others

  • View
    55

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Merox - Mercaptan Removal (pH/ORP)

Mercaptans are organosulfur compounds often found in unrefined or partially refined hydrocarbon feedstocks. They contain several undesirable qualities, including strong odor, corrosivity, and degradation of downstream additives and hydrocarbon end products. A catalytic process is utilized to remove mercaptans for these reasons. Challenges to pH processes exist in both extraction and sweetening Merox processes, including reference fouling, coating, and abrasion.

ChallengesReference electrolyte can be poisoned by ex-cess caustic, mercaptans, disulfides and other contaminants. Coating and plugging of porous reference junction by residual oils. Abrasion of pH measuring membrane due to suspended catalyst fines.

Merox - Mercaptan Removal (pH/ORP)

Specifications

If the process is isolated, an in-line electrode such as the Y-410B-F6 or V-19DB-F6 Series is recommended.

If the process is not isolated, a retractable such as the MK7 or Live Tap model is recommended.

For more information, contact your AlpHa/Van London Co. representative or distributor.

pH Range 0-14 0-14 0-14

Temperature Range 0-130ºC 0-130ºC 0-130ºC

Pressure Range 0-150 PSI @ 25ºC

Body material Ryton Kynar Stainless Steel

Page 2: Merox - Mercaptan Removal (pH/ORP)