1

HISTORYThe H.A. King Company has provided design, consulting and manufacturing services forrubber bonded to metal products for over 50 years. These products have provided solu-tions for vibration, shock and noise problems for many industry applications.

PRODUCTSH.A. King Company was originally founded to provide design services and the manufactureof rubber to metal engine mounting components and special torsional crankshaft vibrationdampers. We have now expanded our activities to include many special rubber to metalisolators to solve problems in many stationary and non vehicular applications.

CAPABILITYAt H.A. King Company, we specialize in rubber to metal bonded products. These are usedto solve any vibration control applications. This means our products are engineered tomeet rigid specifications required by a particular application. Part of our capability is thatwe utilize the flexibility of out-sourcing many of our individual components:

RUBBER COMPOUNDING: Rather than being limited to some in house rubbercompounding methods, we are free to solicit the most up-to-date processes used by theindustries leading rubber compounders. This affords you, the customer, the best of bothworlds competitive pricing and the latest "state-of-the-art,"' rubber compounding.

METAL FABRICATING: we also utilize out-sourcing for the necessary metalstamping used in our products. Again, this allows us to review and purchase the mostcompetitive unit from a price and quality stand point that is available in the industry.

H.A. King Company then processes and assembles these parts into quality isolators,engine mounts and other specialized rubber parts.

SUMMARYWhen you have any problems that are related to vibration, shock or noise control, H.A.King has the capability to provide you with high quality rubber to metal isolators, enginemounts and/or specialized rubber parts.

Please give us a call: (248) 280-0006 or

Contact us at: www.ha-king.com

55053_HAKingtext 10/9/06 7:01 AM Page 1

H. A. KING

2

Table of Contents

PAGEElastomer Selection Guide 3

Cylindrical Mounts 4-25

Center Bolted Mounts 27-30

Bonded Bushing and Snubber 31

Plate Mounts 32-39

Bonded Bushing and Snubber Mounts 40-42

Shear Mounts 43-50

Engine Mounts 51-53

Application Sheets 54-56

Conversion Table 57

55053_HAKingtext 10/9/06 7:01 AM Page 2

H. A. KING

3

ELASTOMER SELECTION GUIDE

The selection of elastomers is an important and crucial step in isolatordesign. In compounding elastomers for isolator use, the objectives are toproduce 1) mechanical properties that fulfill service and performance require-ments, 2) processing characteristics that can be used with existing toolingand equipment, and 3) an elastomer with satisfactory properties that is low incost.

It is important to define all the service conditions and limits thoroughly whenselecting the elastomer that best suits the application. These include operatingtemperatures, environmental conditions (exposure to chemicals and othercontaminants) and performance requirements such as load capacity andresponse to dynamic inputs.

Unless the performance and environmental requirements are particularlystringent, the most cost effective choice would be to use a standardelastomer. H.A. King utilizes these compounds as standards that meet themajority of application requirements.

Natural High DampedProperties NeopreneRubber Silicone

Adhesion to metal Excellent Excellent Good

Tensile strength Excellent Excellent Good

Tear resistance Good Good Fair

Compression resistance Good Fair Fair

Damping Factor, c/cc (approx) 0.05 0.05 0.15

Operating temperature (max) 200°F 200°F 350°F

Stiffness increase (approx) @ -65°F 10x 10x 2x

Oil resistance Poor Good Fair

Ozone resistance Poor Good Excellent

Resistance to sunlight aging Poor Very Good Excellent

Resistance to heat aging Fair Good ExcellentCost Low Low High

55053_HAKingtext 10/9/06 7:01 AM Page 3

H. A. KING

4

H.A. King's Cylindrical Mounts are a family of elastomeric isolators or protectionof equipment an machinery against damaging vibration and shock inputs.Cylindrical mounts are constructed of a resilient elastomeric element bondedbetween two metal isolation system. The small, yet rugged, design and the vastrange of sizes and configurations make the Cylindrical Mounts an ideal choicefor a wide range of applications.

TYPICAL APPLICATIONS•Compressors •Computers •Engine Generator Sets•Pumps •Electronic Units •Motorcycles•Blowers •Relays •Small Tillers & Tampers•Fans •Timing Devices •Garden Tractors & Mowers•Motors •Control Panels •Plant Machinery•Air Conditioning Equip. •Business Machines •Vibratory Feeders

FEATURES• Reduce transmitted vibration from reciprocating or rotating equipment• Prevent transmission of structure-borne noise• Prevent damage to sensitive equipment from vibration and shock• Can be loaded in compression or shear• Available in a wide range of styles, sizes and load ranges

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS

55053_HAKingtext 10/9/06 7:01 AM Page 4

H. A. KING

1105-801 3/8 5/16 7/32 4.5 6.5

1105-802 3/8 5/16 7/32 5.5 9.0

1105-803 3/8 5/16 7/32 8.0 12.0

1105-804 3/8 5/16 7/32 10.0 15.5

1105-805 3/8 5/16 7/32 12.5 18.0

1105-811 3/8 1/2 3/8 2.5 5.0

1105-812 3/8 1/2 3/8 3.5 6.5

1105-813 3/8 1/2 3/8 5.5 11.0

1105-814 3/8 1/2 3/8 7.0 14.0

1105-815 3/8 1/2 3/8 8.5 17.0

5

1000 SERIES ISOLATORSRECTANGULAR MOUNTS • 8-32 THREADS

SQ STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER (square) T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

T

SQ

55053_HAKingtext 10/9/06 7:01 AM Page 5

H. A. KING

6

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 6-32 THREADS

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1000-101 .5 3.0

1000-102 .7 4.0

1000-103 2,4,5 3/8 5/16 3/8 1.0 5.0

1000-104 1.2 6.0

1000-105 1.5 7.0

1000-121 2.0 4.2

1000-122 2.9 5.7

1000-123 2,4,5 7/16 7/16 3/8 4.2 8.5

1000-124 5.8 10.4

1000-125 6.9 11.9

1000-131 2.7 4.9

1000-132 3.6 6.4

1000-133 2,4,5 7/16 1/2 3/8 5.6 10.4

1000-134 6.4 13.3

1000-135 7.4 15.8

1000-141 3.6 6.5

1000-142 4.5 9.2

1000-143 2,4,5 1/2 1/2 3/8 7.3 13.2

1000-144 9.2 19.3

1000-145 11.2 27.2

STYLE 2 STYLE 4 STYLE 5

T T T

DIA.DIA.DIA.

55053_HAKingtext 10/9/06 7:01 AM Page 6

H. A. KING

7

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1100-101 .5 3.0

1100-102 .7 4.0

1100-103 1,2,4,5 3/8 1/4 3/8 1.0 5.0

1100-104 1.2 6.0

1100-105 1.5 7.0

1100-106 .3 2.5

1100-107 .5 3.5

1100-108 2,5 3/8 5/32 3/8 .8 4.5

1100-109 1.0 5.5

1100-110 1.2 6.5

1100-111 .8 4.5

1100-112 1.2 6.2

1100-113 1,2,4,5 3/8 1/2 3/8 1.7 8.0

1100-114 1.9 9.5

1100-115 2.3 10.9

1100-116 .5 3.0

1100-117 .7 4.0

1100-118 2,5 3/8 5/16 3/8 1.0 5.0

1100-119 1.2 6.0

1100-120 1.5 7.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 8-32 THREADS

STYLE 1 STYLE 2 STYLE 4 STYLE 5

DIA. DIA. DIA. DIA.

T T T T

55053_HAKingtext 10/9/06 7:01 AM Page 7

H. A. KING

8

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1100-121 2.7 4.9

1100-122 3.6 6.4

1100-123 1,2,3,4,5 7/16 1/2 3/8 5.6 10.4

1100-124 6.4 13.3

1100-125 7.4 15.8

1100-126 4.5 8.5

1100-127 7.0 12.0

1100-128 1,2,3,4,5 1/2 3/4 3/8 9.0 16.0

1100-129 12.0 20.0

1100-130 15.0 25.0

1100-131 4.4 8.0

1100-132 6.7 12.0

1100-133 1,2,3,4,5 9/16 1/2 3/8 9.0 16.0

1100-134 12.0 25.0

1100-135 15.0 33.0

1100-136 4.2 7.8

1100-137 6.3 11.5

1100-138 1,2,3,4,5 9/16 .66 3/8 8.5 15.3

1100-139 11.4 22.2

1100-140 14.1 25.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 8-32 THREADS

STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5

T

DIA. DIA. DIA. DIA. DIA.

T T T T

55053_HAKingtext 10/9/06 7:01 AM Page 8

H. A. KING

9

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1100-141 4.0 8.5

1100-142 6.0 12.0

1100-143 1,2,3,4,5 9/16 3/4 3/8 8.5 16.0

1100-144 11.5 20.0

1100-145 14.5 25.0

1100-146 2.0 4.2

1100-147 2.9 5.7

1100-148 1,2,3,4,5 7/16 7/16 3/8 4.2 8.5

1100-149 5.8 10.4

1100-150 6.9 11.9

1100-151 4.6 9.0

1100-152 6.8 13.0

1100-153 1,2,3,4,5 5/8 1/2 3/8 9.5 17.0

1100-154 13.0 26.0

1100-155 15.0 31.0

1100-161 8.0 16.0

1100-162 11.0 22.0

1100-163 1,2,3,4,5 3/4 1/2 3/8 15.0 30.0

1100-164 18.0 35.0

1100-165 21.0 40.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 8-32 THREADS

STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5

T

DIA. DIA. DIA. DIA. DIA.

T T T T

55053_HAKingtext 10/9/06 7:01 AM Page 9

H. A. KING

10

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1200-101 4.4 8.0

1200-102 6.7 12.0

1200-103 2,4,5 9/16 1/2 3/8 9.4 16.0

1200-104 12.0 25.0

1200-105 15.0 33.0

1200-106 3.0 6.0

1200-107 5.2 8.0

1200-108 2,5 9/16 5/16 3/8 7.0 12.0

1200-109 9.0 19.0

1200-110 11.0 27.0

1200-121 9.0 23.0

1200-122 12.0 30.0

1200-123 2,4,5 3/4 5/8 3/8 16.0 37.0

1200-124 18.5 41.0

1200-125 21.0 45.5

1200-131 8.5 21.0

1200-132 1.2 31.0

1200-133 2,5 1 3/8 3/8 17.5 36.5

1200-134 18.0 40.0

1200-135 22.0 46.0

1200-141 18.0 35.0

1200-142 25.0 45.0

1200-143 2,4,5 1 3/4 3/8 34.0 60.0

1200-144 40.0 80.0

1200-145 48.0 92.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 10-32 THREADS

STYLE 2 STYLE 4 STYLE 5

T T T

DIA.DIA.DIA.

55053_HAKingtext 10/9/06 7:01 AM Page 10

H. A. KING

11

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1300-101 5.2 9.2

1300-102 7.3 13.1

1300-103 1,2,4,5 5/8 5/8 1/2 10.1 17.0

1300-104 13.2 24.0

1300-105 14.0 28.0

1300-111 8.5 22.0

1300-112 12.0 29.0

1300-113 2,4,5 3/4 3/8 1/2 16.0 35.0

1300-114 20.0 40.0

1300-115 25.0 45.0

1300-116 10.0 22.0

1300-117 12.5 32.0

1300-118 2,4,5 1 1/4 1/2 17.0 36.5

1300-119 19.5 43.0

1300-120 21.0 46.5

1300-121 8.5 22.0

1300-122 13.0 30.0

1300-123 1,2,4,5 3/4 1/2 1/2 16.5 36.0

1300-124 19.2 42.5

1300-125 26.5 47.0

1300-126 9.0 20.0

1300-127 11.5 30.0

1300-128 2,5 1 3/8 1/2 15.5 35.0

1300-129 18.0 41.0

1300-130 20.5 45.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 1/4-20 THREADS

STYLE 1 STYLE 2 STYLE 4 STYLE 5

T T T T

DIA. DIA. DIA. DIA.

55053_HAKingtext 10/9/06 7:01 AM Page 11

H. A. KING

12

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1300-131 9.0 23.0

1300-132 12.0 30.0

1300-133 1,2,4,5 3/4 5/8 1/2 16.0 37.0

1300-134 18.5 41.0

1300-135 21.0 45.5

1300-136 9.5 24.0

1300-137 14.0 32.0

1300-138 1,2,4,5 3/4 3/4 1/2 18.0 38.0

1300-139 21.0 45.0

1300-140 28.5 50.0

1300-141 8.0 22.5

1300-142 12.5 30.5

1300-143 1,2,4,5 3/4 1 1/2 17.0 36.5

1300-144 20.0 43.0

1300-145 27.0 48.5

1300-146 19.0 40.0

1300-147 21.0 43.0

1300-148 1,2,4,5 1 17/32 1/2 37.0 74.0

1300-149 42.0 175.0

1300-150 49.0 380.0

1300-151 18.0 35.0

1300-152 25.0 45.0

1300-153 1,2,4,5 1 3/4 1/2 34.0 60.0

1300-154 40.0 80.0

1300-155 45.0 88.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 1/4-20 THREADS

STYLE 1 STYLE 2 STYLE 4 STYLE 5

DIA. DIA. DIA. DIA.

T T T T

55053_HAKingtext 10/9/06 7:01 AM Page 12

H. A. KING

13

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1300-156 18.5 37.5

1300-157 23.0 44.0

1300-158 1,2,4,5 1 5/8 1/2 35.0 57.0

1300-159 41.0 77.0

1300-160 47.0 84.0

1300-161 15.0 37.0

1300-162 23.0 50.0

1300-163 1,2,4,5 1 1 1/2 35.0 62.0

1300-164 43.0 85.0

1300-165 48.0 91.0

1300-166 13.0 34.5

1300-167 21.5 48.0

1300-168 1,2,4,5 1 1 1/4 1/2 33.0 60.0

1300-169 41.0 83.5

1300-170 46.5 89.0

1300-171 30.0 55.0

1300-172 40.0 75.0

1300-173 1,2,4,5 1 1/4 3/4 1/2 50.0 100

1300-174 60.0 140

1300-175 70.0 160

1300-176 32.0 56.0

1300-177 37.0 82.0

1300-178 1,2,4,5 1 1/4 1 1/2 48.0 115

1300-179 63.0 123

1300-180 72.0 130

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 1/4-20 THREADS

STYLE 1 STYLE 2 STYLE 4 STYLE 5

T T T T

DIA. DIA. DIA. DIA.

55053_HAKingtext 10/9/06 7:02 AM Page 13

H. A. KING

14

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1400-091 10.0 25.0

1400-092 13.0 30.0

1400-093 1,2,4,5 3/4 1 1/2 15.8 39.0

1400-094 22.0 47.0

1400-095 31.0 59.0

1400-096 9.0 23.0

1400-097 12.0 30.0

1400-098 1,2,4,5, 3/4 5/8 1/2 16.0 37.0

1400-099 18.5 41.0

1400-100 21.0 45.5

1400-101 19.0 37.0

1400-102 23.5 44.5

1400-103 1,2,5 1 5/8 1/2 35.5 56.0

1400-104 41.0 77.0

1400-105 47.5 84.0

1400-106 20.0 39.0

1400-107 22.0 44.0

1400-108 1,2,4,5 1 17/32 1/2 37.0 54.0

1400-109 42.0 74.0

1400-110 50.0 80.0

1400-111 18.0 35.0

1400-112 25.0 45.0

1400-113 1,2,4,5 1 3/4 1/2 34.0 60.0

1400-114 40.0 80.0

1400-115 45.0 88.0

1400-116 9.0 20.0

1400-117 11.5 30.0

1400-118 2,5 1 3/8 1/2 15.5 35.0

1400-119 18.0 41.0

1400-120 20.5 45.0

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 5/16-18 THREADS

STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5

DIA. DIA. DIA. DIA.

T T T T T

DIA.

55053_HAKingtext 10/9/06 7:02 AM Page 14

15

H. A. KING

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1400-121 15.0 37.0

1400-122 23.0 50.0

1400-123 1,2,3,4,5 1 1 1/2 35.0 62.0

1400-124 43.0 85.0

1400-125 48.0 91.0

1400-126 9.5 24.0

1400-127 14.0 32.0

1400-128 1,2,4,5 3/4 3/4 1/2 18.0 38.0

1400-129 22.0 45.0

1400-130 28.5 50.0

1400-131 16.5 40.0

1400-132 25.0 52.0

1400-133 1,2,4,5 1 1 1/4 5/8 37.0 63.0

1400-134 45.0 87.0

1400-135 50.0 98.0

1400-146 N/A 22.0

1400-147 N/A 28.5

1400-148 2 3/4 3/8 1/2 N/A 35.0

1400-149 N/A 41.0

1400-150 N/A 48.5

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 5/16-18 THREADS

STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5

T T T T T

DIA. DIA. DIA. DIA. DIA.

55053_HAKingtext 10/9/06 7:02 AM Page 15

H. A. KING

16

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 5/16-18 THREADS

STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1400-156 30.0 55.0

1400-157 40.0 75.0

1400-158 1,2,4,5 1 1/4 3/4 9/16 50.0 100

1400-159 60.0 140

1400-160 70.0 155

1400-161 30.0 55.0

1400-162 40.0 80.0

1400-163 1,2,3,4,5 1 1/4 1 9/16 49.0 112

1400-164 60.0 126

1400-165 69.0 140

1400-166 32.0 56.0

1400-167 37.0 82.0

1400-168 1,2,3,4,5 1 1/4 7/8 9/16 48.0 115

1400-169 63.0 123

1400-170 75.0 135

1400-171 21.0 41.0

1400-172 31.0 64.0

1400-173 1,2,3,4,5 1 1/4 1 1/4 9/16 48.0 90.0

1400-174 63.0 120

1400-175 72.0 140

1400-176 N/A 75.0

1400-177 N/A 100

1400-178 2 1 1/4 1/4 9/16 N/A 132

1400-179 N/A 146

1400-180 N/A 160

1400-181 36.0 93.0

1400-182 46.0 118

1400-183 2,4,5 1 3/8 5/8 9/16 57.0 158

1400-184 67.0 185

1400-185 77.0 220

DIA. DIA. DIA. DIA. DIA.

T T T T T

55053_HAKingtext 10/9/06 7:02 AM Page 16

H. A. KING

17

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 5/16-18 THREADS

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

1400-191 30.0 55.0

1400-192 40.0 81.0

1400-193 1,2,4,5 1 3/8 1 9/16 50.0 110

1400-194 61.0 125

1400-195 70.0 142

1400-201 30.0 90.0

1400-202 42.0 110

1400-203 2,4,5 1 3/8 1 1/2 9/16 53.0 148

1400-204 62.0 179

1400-205 70.0 195

1400-206 23.5 44.5

1400-207 35.0 67.0

1400-208 2,4,5 1 1/2 3/4 9/16 49.5 102

1400-209 63.5 115

1400-210 72.0 125

1400-211 22.0 43.0

1400-212 33.0 65.0

1400-213 2,4,5 1 1/2 1 9/16 48.0 100

1400-214 62.0 110

1400-215 70.0 119

1400-216 20.0 41.0

1400-217 31.5 63.0

1400-218 2,4,5 1 1/2 1.2 9/16 46.0 97.5

1400-219 60.0 107

1400-220 67.5 115

1400-246 18.0 39.5

1400-247 24.5 61.0

1400-248 2,4,5 1 1/2 1 1/2 9/16 44.5 96.0

1400-249 57.5 105

1400-250 65.0 112

STYLE 2 STYLE 4 STYLE 5

DIA. DIA. DIA.

T T T

55053_HAKingtext 10/9/06 7:02 AM Page 17

H. A. KING

18

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE

1500-106 18.0 37.0

1500-107 25.0 50.0

1500-108 2,4,5 1 1 3/8 35.0 62.0

1500-109 43.0 85.0

1500-110 48.0 91.0

1500-111 22.0 95

1500-112 33.0 135

1500-113 2,4,5 1 1/2 1 3/4 48.0 185

1500-114 62.0 210

1500-115 70.0 210

1500-126 45 250

1500-127 70 310

1500-128 2,4,5 2 3/4 3/4 90 370

1500-129 110 450

1500-130 140 560

STYLE 2 STYLE 4 STYLE 5

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 3/8-16 THREADS

DIA. DIA. DIA.

T T T

55053_HAKingtext 10/9/06 7:02 AM Page 18

H. A. KING

19

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS • 3/8-16 THREADS

STYLE 2 STYLE 5

T T

DIA. DIA.

STYLES STANDARD STUD MAXIMUM STATIC LOAD (lbs.)PART NUMBER AVAILABLE DIA T LENGTH

(in) (in) (in) Shear Compression

AVAILABLE IN NATURAL AND NEOPRENE

1500-131 35.0 80.0

1500-132 40.0 100

1500-133 2,5 2 1 1/2 3/4 55.0 165

1500-134 65.0 240

1500-135 80.0 350

1500-141 24.0 80.0

1500-142 29.0 135

1500-143 2,5 2 1 3/4 3/4 58.0 280

1500-144 79.0 360

1500-145 29.0 8.5

1500-151 32.0 140

1500-152 44.0 250

1500-153 2,5 2 2 1/8 3/4 50.0 110

1500-154 58.0 285

1500-155 92.0 380

55053_HAKingtext 10/9/06 7:02 AM Page 19

PART NUMBER D1 D2 T S STATIC LOAD DYNAMIC LOAD(in) (in) (in) (in) (lbs) (lbs)

AVAILABLE IN NATURAL AND NEOPRENE

1600-101 44 90

1600-102 49 100

1600-103 1 1/2 1 1 1/4 9/16 56 125

1600-104 62 150

1600-105 68 160

1600-106 44 90

1600-107 49 100

1600-108 1 1/2 1 1 1/4 5/8 56 125

1600-109 62 150

1600-110 68 160

1600-111 44 90

1600-112 49 100

1600-113 1 1/2 1 1 1/4 3/4 56 125

1600-114 62 150

1600-115 68 160

1600-121 44 90

1600-122 49 100

1600-123 1 1/2 1 1 1/4 1 1/8 56 125

1600-124 62 150

1600-125 68 160

H. A. KING

20

1000 SERIES ISOLATORSCONICAL MOUNTS • 5/16-18 THREADS

TS

D1O D2O

55053_HAKingtext 10/9/06 7:02 AM Page 20

H. A. KING

21

1000 SERIES ISOLATORSCONICAL MOUNTS • 5/16-18 THREADS

PART NUMBER D1 D2 T S STATIC LOAD DYNAMIC LOAD(in) (in) (in) (in) (lbs) (lbs)

AVAILABLE IN NATURAL AND NEOPRENE

1600-126 44 90

1600-127 49 100

1600-128 1 1/2 1 1 1/4 1 56 125

1600-129 62 150

1600-130 68 160

1600-131 44 90

1600-132 49 100

1600-133 1 1/2 1 1 1/4 1 1/2 56 125

1600-134 62 150

1600-135 68 160

1600-141 44 90

1600-142 49 100

1600-143 1 1/2 1 1 1/4 1/2 56 125

1600-144 62 150

1600-145 68 160

1600-301 40 85

1600-302 55 115

1600-303 1 5/8 1 3/8 1 5/8 80 175

1600-304 100 205

1600-305 180 350

D1O D2O

S T

55053_HAKingtext 10/9/06 7:02 AM Page 21

H. A. KING

22

1000 SERIES ISOLATORS

D2OD1O

S ST

1600-501 30

1600-502 40

1600-503 50

1600-504 60

1600-505 70

PART DUROMETERNUMBER

1600-541 30

1600-542 40

1600-543 50

1600-544 60

1600-545 70

PART DUROMETERNUMBER

1600-511 30

1600-512 40

1600-513 50

1600-514 60

1600-515 70

PART DUROMETERNUMBER

1 1/4"

1 1/2"

.1

11/16"

1 5/8"

0.19 + 0.03

2.00 + 0.06

0.94 + 0.06

0.375—16UNC-2A

RO.12 + 0.03

RO.25 + 0.03

2.00 + 0.062.25 + 0.03

90° NCM

2.50"

55053_HAKingtext 10/9/06 7:02 AM Page 22

H. A. KING

23

1000 SERIES ISOLATORS

1602-561 30

1602-562 40

1602-563 50

1602-564 60

1602-565 70

PART DUROMETERNUMBER

1.75 O2.50 O A A

.63 O HOLE

1.635O MOUNTING HOLE1.625

1.25 O

.20MOUNT

REINFORCEMENT

1.19

H. A. KING

24

PART DIA. T THREAD S DUROMETERNUMBER (in.) (in.) (in.)

1620-151 301620-152 401620-153 1 3/4 3 5/16-18 5/8 501620-154 601620-155 70

PART DIA. T THREAD S DUROMETERNUMBER (in.) (in.) (in.)

PART DIA. T THREAD S DUROMETERNUMBER (in.) (in.) (in.)

1620-401 301620-402 401620-403 3 1 3/4 5/16-18 1.31 501620-404 601620-405 70

1620-301 301620-302 401620-303 3 2 3/4 1/2-13 .81 501620-304 601620-305 70

S T

DIA.

S

DIA.

T

DIA.

TS

1.75

AVAILABLE IN NATURAL AND NEOPRENE NON STANDARD STUD LENGTHS AVAILABLE

AVAILABLE IN NATURAL AND NEOPRENE

AVAILABLE IN NATURAL AND NEOPRENE

1000 SERIES ISOLATORSBUMPERS

55053_HAKingtext 10/9/06 7:02 AM Page 23

H. A. KING

25

1700-101 110 260

1700-102 140 330

1700-103 2 3/4 2 1 1/32 1/2-13 1 1/4 165 380

1700-104 190 430

1700-105 230 500

1700-111 110 260

1700-112 140 330

1700-113 2 3/4 2 1 1/32 1/2-20 29/32 165 380

1700-114 190 430

1700-115 230 500

PART NUMBER D1 D2 T THREAD S STATIC LOAD DYNAMIC LOAD(in) (in) (in) (in) (lbs) (lbs)

AVAILABLE IN NATURAL AND NEOPRENE

D2OD1O

S ST

55053_HAKingtext 10/9/06 7:02 AM Page 24

H. A. KING

26

1000 SERIES ISOLATORSCYLINDRICAL MOUNTS

PART STYLE DIA. T THREAD COMPRESSION SHEARNUMBER (in.) (in.) (lbs.) (lbs.)

1830-301 90 40

1830-302 120 60

1830-303 3 2 1 3/4 1/2-13 160 80

1830-304 225 100

1830-305 480 200

1830-311 80 30

1830-312 100 40

1830-313 3 2 2 1/8 1/2-13 135 55

1830-314 180 70

1830-315 400 140

1810-331 90 N/A

1810-332 150 N/A

1810-333 1 2 1 3/4 1/2-13 275 N/A

1810-334 625 N/A

1810-335 780 N/A

1810-341 95 N/A

1810-342 160 N/A

1810-343 1 2 1 1/2-13 300 N/A

1810-344 650 N/A

1810-345 725 N/A

1810-361 60 15

1810-362 90 30

1810-363 3 2 2 5/8 1/2-13 125 45

1810-364 160 50

1810-365 385 100

DIA.

T

AVAILABLE IN NATURAL AND NEOPRENE

STYLE 1 STYLE 3T

55053_HAKingtext 10/9/06 7:02 AM Page 25

H. A. KING

27

H.A. King's Center-Bolted Mounts isolate vibrations, control shock and reducenoise due to structure-borne vibrations. The one piece design, in which aresilient elastomer is bonded to a tubular steel inner member, assures properinstallation of the mount and improved fatigue life over unbonded designs.Standard elastomer is natural rubber. Neoprene elastomer is also available.

TYPICAL APPLICATIONS•Engine/Transmissions •Compressors •Generators•Cabs •Pumps •Accessory Equipment•Radiators •Fuel Tanks •Industrial Machinery

FEATURES• Efficiently isolates vibration• Attenuates shock inputs• Prevent transmission of structure-borne noise• Dynamically effective in all directions• Built-in rebound protection• Long service life• Low cost installation

2000 SERIES ISOLATORSCENTER • BOLTED MOUNTS

55053_HAKingtext 10/9/06 7:02 AM Page 26

0.31 0.22 0.69 0.40 1.25 1.10 0.81 0.75 1.09 0.80 0.06

0.31 0.22 0.62 0.40 1.25 1.10 0.81 0.75 1.09 1.02 0.06

0.41 0.38 1.00 0.47 2.00 1.50 1.24 1.12 1.75 1.25 0.06

0.41 0.38 1.00 0.52 2.00 1.50 1.24 1.12 1.75 1.25 0.06

0.50 0.53 1.00 0.53 2.25 1.70 1.35 1.25 2.00 1.25 0.06

0.50 0.53 1.00 .625 2.25 1.70 1.35 1.25 2.00 1.25 0.06

2001-01 30 1,000

2001-02 50 2,000

2001-03 80 4,200

2001-04 140 9,750

2001-11 45 1,800

2001-12 75 3,000

2001-13 125 5,000

2001-14 160 6,400

2002-01 130 2,000

2002-02 190 3,875

2002-03 300 7,500

2002-04 520 15,500

2002-11 130 2,000

2002-12 190 3,875

2002-13 300 7,500

2002-14 520 15,500

2003-01 230 3,400

2003-02 360 6,000

2003-03 520 10,600

2003-04 720 18,200

2003-11 230 3,400

2003-12 360 6,000

2003-13 520 10,600

2003-14 720 18,200

H. A. KING

28

2000 SERIES ISOLATORSCENTER • BOLTED MOUNTS

AXIALPART MAX SPRING A B C D E F G H I J R

NUMBER LOAD RATE (MIN) (MIN) (MIN)(lbs/in.)

E (MIN. FLAT SURFACE)

LOAD

WITHOUTAPPLIED LOAD

SUPPORTC

REBOUND WASHERTYPICAL INSTALLATION

HF

A

B

RJ

G

ID

55053_HAKingtext 10/9/06 7:02 AM Page 27

29

H. A. KING

2004-01 230 3.400

2004-02 360 6,000

2004-03 520 10,600

2004-04 720 18,200

2004-11 230 3,400

2004-12 360 6,000

2004-13 520 10,600

2004-14 720 18,200

2005-01 400 4,450

2005-02 540 7,500

2005-03 750 12,900

2005-04 1100 22,000

2006-01 600 5,200

2006-02 800 9,400

2006-03 1100 15,000

2006-04 1500 23,500

2007-01 950 6,500

2007-02 1300 10,700

2007-03 1850 18,500

2007-04 2400 26,700

2000 SERIES ISOLATORSCENTER • BOLTED MOUNTS

AXIALPART MAX SPRING A B C D E F G H I J R

NUMBER LOAD RATE (MIN) (MIN) (MIN)(lbs/in.)

0.62 0.53 1.38 0.53 2.25 1.70 1.35 1.25 2.00 1.61 0.06

0.62 0.53 1.38 0.64 2.25 1.70 1.35 1.25 2.00 1.61 0.06

0.75 0.62 1.75 0.64 2.85 2.20 1.61 1.50 2.50 2.00 0.06

0.93 0.71 2.00 0.64 3.50 2.50 1.96 1.81 2.97 2.22 0.12

0.75 0.94 2.12 0.77 4.25 2.70 2.20 2.00 3.68 2.50 0.12

E (MIN. FLAT SURFACE)

LOAD

WITHOUTAPPLIED LOAD

SUPPORTC

REBOUND WASHERTYPICAL INSTALLATION

HF

A

B

RJ

G

ID

55053_HAKingtext 10/9/06 7:02 AM Page 28

30

H. A. KING

2012-01 60 660

2012-02 100 1,112

2012-03 200 2,230

2012-04 300 3,300

2012-11 60 660

2012-12 100 1,112

2012-13 200 2,230

2012-14 300 3,300

2000 SERIES ISOLATORSCENTER • BOLTED MOUNTS

AXIALPART MAX SPRING A B C D E F G H I J R

NUMBER LOAD RATE (MIN) (MIN) (MIN)(lbs/in.)

.38 .55 1.07 .41 1.50 1.50 .95 .875 1.25 1.44 .06

.38 .55 1.07 .34 1.50 1.50 .95 .875 1.25 1.44 .06

E (MIN. FLAT SURFACE)

LOAD

WITHOUTAPPLIED LOAD

SUPPORTC

REBOUND WASHERTYPICAL INSTALLATION

HF

A

B

RJ

G

ID

55053_HAKingtext 10/9/06 7:02 AM Page 29

H. A. KING

31

2100 SERIES ISOLATORSBONDED BUSHING AND SNUBBER

AXIALPART MAX SPRING A B C D E F G H

NUMBER LOAD RATE (MIN) (MIN)(lbs/in.)

.50 .78 1.94 .53 2.25 2.25 1.23 1.88

H

B

D

GMetalReinforcement

Frame

Support Structure

Isolated Equipment

C

A

2100-01 16 100

2100-02 20 150

2100-03 25 200

2100-04 32 250

2100-05 40 300

E

F

C

55053_HAKingtext 10/9/06 7:02 AM Page 30

32

H. A. KING

3000 SERIES ISOLATORSPLATE MOUNTS

H.A. King's Plate Mounts are a family of versatile low-frequency isolatorsrecommended to isolate steady state vibration and control occasional shockinputs. These lightweight and compact isolators provide multi-directionalisolation from lower frequency disturbances.

TYPICAL APPLICATIONS•Medical Equipment •Business Equipment •Computers•Compressors •Office Machines •Instrumentation•Small Pumps •Electronic Equipment •Appliances

FEATURES• Excellent isolation of low frequency vibration inputs• Controls occasional shock inputs• Prevent transmission of structure-borne noise• Available in a wide varieties of sizes and load ranges

55053_HAKingtext 10/9/06 7:02 AM Page 31

H. A. KING

33

3001-01 4 62 .75 .45

3001-02 8 125 .75 .45

3001-03 12 190 .75 .45

3001-04 20 330 .75 .45

3000 SERIES ISOLATORSPLATE MOUNTS

MAX AXIALPART STATIC SPRING A B

NUMBER LOAD RATE height height(lbs.) (lbs./in.)

1.414

.14 DIA.

1.25 DIA. 1.68

.17 DIA.

1.0 DIA.

A.

.17

B

.035

.17 DIA.

1.0 DIA.

A.

.17

B

.035

.14 DIA.

1.25 TYP.

1.0 TYP.3001-51 4 62 .75 .45

3001-52 8 125 .75 .45

3001-53 12 190 .75 .45

3001-54 20 330 .75 .45

MAX AXIALPART STATIC SPRING A B

NUMBER LOAD RATE height height(lbs.) (lbs./in.)

55053_HAKingtext 10/9/06 7:02 AM Page 32

H. A. KING

34

3002-01 3 33

3002-02 6 63

3002-03 9 100

3002-04 12 130

3002-05 14 163

3002-06 17 192

3002-07 20 220

3002-08 26 290

3000 SERIES ISOLATORSPLATE MOUNTS

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

3002-51 3 33

3002-52 6 63

3002-53 9 100

3002-54 12 130

3002-55 14 163

3002-56 17 192

3002-57 20 220

3002-58 26 290

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

1.78 DIA.

.16 DIA.

1.95

2.34

.26 DIA.

1.50 DIA.

.050

.63

.20

.39

.26 DIA.

1.50 DIA.

.050

.63

.20

.39

.16 DIA.

1.38 TYP.

1.78 TYP.

55053_HAKingtext 10/9/06 7:02 AM Page 33

H. A. KING

35

3003-01 12 67

3003-02 20 110

3003-03 30 155

3003-04 45 240

3003-05 60 315

3000 SERIES ISOLATORSPLATE MOUNTS

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

3003-51 12 67

3003-52 20 110

3003-53 30 155

3003-54 45 240

3003-55 60 315

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

.19 DIA.

2.25 DIA. 2.98

2.475

2.00 DIA.

.56

1.062

.391 DIA.

.34

.062

2.00 DIA.

.56

1.062

.391 DIA.

.34

.062

.16 DIA.

2.25 TYP.

1.75 TYP.

55053_HAKingtext 10/9/06 7:02 AM Page 34

H. A. KING

36

3004-00 20 160

3004-01 30 230

3004-02 40 300

3004-03 50 385

3004-04 70 530

3004-05 90 690

3000 SERIES ISOLATORSPLATE MOUNTS

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

3004-50 20 160

3004-51 30 230

3004-52 40 300

3004-53 50 385

3004-54 70 530

3004-55 90 690

PART MAXIMUM AXIALNUMBER STATIC SPRING RATE

(lbs.) (lbs./in.)

2.475

2.982.25 DIA.

.19 DIA.

.39 DIA.

2.00 DIA.

1.015

.062

.25

.59

.39 DIA.

2.00 DIA.

1.015

.062

.25

.59

.19 DIA.

2.25 TYP.

1.75 TYP.

55053_HAKingtext 10/9/06 7:02 AM Page 35

H. A. KING

37

3000 SERIES ISOLATORSPLATE MOUNTS

AXIAL MAXPART SPRING LOAD A D E F G I Q R S U

NUMBER RATE (lbs.) +.008 +.003 (MIN)(lbs./in.) -.005 -.002

3106-01 5 1

3106-02 11 2

3106-03 16 3

3106-04 21 4

3106-05 32 6

1.00 0.166 0.166 0.032 0.53 0.84 1.414 0.62 1.66 0.38

AXIAL MAXPART SPRING LOAD A B C D E F G I O U

NUMBER RATE (lbs.) +.008 +.003(lbs./in.) -.005 -.002

3106-51 5 1

3106-52 11 2

3106-53 16 3

3106-54 21 4

3106-55 32 6

1.00 1.25 1.000 0.166 0.166 0.032 0.53 0.84 1.414 0.38

E

R

Q

S

F

D

A

I

GU

GU

I

D

F

A

O

C

B

BC

E

A A

55053_HAKingtext 10/9/06 7:02 AM Page 36

H. A. KING

38

3000 SERIES ISOLATORSPLATE MOUNTS

AXIAL MAXPART SPRING LOAD A D E F G I Q R S U

NUMBER RATE (lbs.) +.008 +.003 (MIN)(lbs./in.) -.005 -.002

3156-01 32 6

3156-02 48 9

3156-03 69 13

3156-04 85 16

1.50 0.257 0.166 0.050 0.55 0.97 1.945 0.88 2.32 0.38

AXIAL MAXPART SPRING LOAD A B C D E F G I O U

NUMBER RATE (lbs.) +.008 +.003(lbs./in.) -.005 -.002

3156-51 32 6

3156-52 48 9

3156-53 69 13

3156-54 85 16

1.50 1.75 1.375 0.257 0.166 0.050 0.55 0.97 1.945 0.38

E

R

Q

S

F

D

A

I

GU

GU

I

D

F

A

O

C

B

BC

E

A A

SECTION "A-A"

SECTION "A-A"

55053_HAKingtext 10/9/06 7:02 AM Page 37

H. A. KING

39

3011-01 30

3011-02 40

3011-03 50

3011-04 60

3011-05 70

PART DUROMETERNUMBER

2.88 DIA.

1.12

.328 DIA.

2.562

.125

.516 DIA.

3.62

2.562

3000 SERIES ISOLATORSPLATE MOUNTS

3020 SERIES ISOLATORS

3.25

3.25

1.50

1.75

2.375

.344 Dia.

1.00.07

3.13.180

.121.515

1.2

5/16" - 18THD 3020-01 30

3020-02 40

3020-03 50

3020-04 60

3020-05 70

PART DUROMETERNUMBER

55053_HAKingtext 10/9/06 7:02 AM Page 38

H. A. KING

40

H.A. King's 5000 Series Bonded Bushing and Snubber Mounts are designed toabsorb extreme static and dynamic forces. This system also absorbs forces inthe rebound mode. These mounts are designed for engines, cabs and auxiliaryequipment for the on and off highway, military, farm, and construction vehicles.

TYPICAL APPLICATIONS•Engines •Vehicular Cabs •Vehicular Electronics•Radiators •Gas Tanks •Transmission and Transfer Cases

FEATURES• Isolates static and dynamic loads in all directions• Built-in rebound protection• Ease of installation• Operational temperature range of -40°F to 200°F• Available in a wide range of sizes and load ranges

5000 SERIES ISOLATORSBONDED BUSHING AND SNUBBER

55053_HAKingtext 10/9/06 7:02 AM Page 39

41

H. A. KING

5001-01 35 185001-02 80 275001-03 103 365001-04 235 455001-05 280 555002-01 65 455002-02 125 805002-03 170 1255002-04 275 1905002-05 390 2905003-01 100 805003-02 180 1205003-03 250 1755003-04 350 2655003-05 500 3705004-01 150 1105004-02 300 2205004-03 400 3005004-04 500 4005004-05 600 5805006-01 35 185006-02 80 275006-03 103 365006-04 235 455006-05 280 555007-01 35 185007-02 80 275007-03 103 365007-04 235 455007-05 280 55

5000 SERIES ISOLATORSBONDED BUSHING AND SNUBBER

PART RATED (lbs.) RATED (lbs.) A B C D E F G HNUMBER AXIAL LOAD RADIAL LOAD (REF) (REF)

1.25 .50 1.25 .39 .52 .78 .53 .37

1.94 .78 1.87 .53 .77 1.31 .78 .50

2.50 .90 2.53 .64 .89 1.54 .90 .75

2.88 1.0 3.5 .94 1.35 2.30 1.36 1.00

1.00 .50 1.25 .39 .52 .78 .53 .125

1.00 .50 1.25 .32 .52 .78 .53 .125

TYPICAL INSTALLATION

LoadDirection

EquipmentIsolated

SupportingStructure

ReboundWasher

C

D

B

A

E

F

B

GC

H

BOLT

55053_HAKingtext 10/9/06 7:02 AM Page 40

42

H. A. KING

5008-01 10 55008-02 20 75008-03 27 95008-04 40 115008-05 50 155009-01 35 185009-02 80 275009-03 103 365009-04 235 455009-05 280 55

5000 SERIES ISOLATORSBONDED BUSHING AND SNUBBER

PART RATED (lbs.) RATED (lbs.) A B C D E F G HNUMBER AXIAL LOAD RADIAL LOAD (REF) (REF)

.580 .25 .75 .257 .375 .50 .41 .125

1.25 .50 1.31 .39 .52 .78 .53 .37

TYPICAL INSTALLATION

LoadDirection

EquipmentIsolated

SupportingStructure

ReboundWasher

C

D

B

A

E

F

B

GC

H

BOLT

55053_HAKingtext 10/9/06 7:02 AM Page 41

H. A. KING

43

H.A. King's 7000 Series Shear Mounts are normally composed of two metal partswith elastomeric compound in between. This system enables the Shear Mountsto be able to absorb a high level of G's. The Shear Mounts help providea cost effective protection for numerous types of equipment.

TYPICAL APPLICATIONS•Engines Containers •HVAC Equipment •Computers and Generator Sets•Highway Rollers •Gas and Generator Sets •Vibratory Compactors•Vibratory Feeders •Missiles and Missile Transmission and Transfer Cases

Components Containers Containers

FEATURES• Excellent load carrying capacity• Numerous configurations for ease of installation and maintenance• Operational temperature range of -40°F to 160°F• Available in a wide range of sizes and load ranges

7000 SERIES ISOLATORSSHEAR MOUNTS

55053_HAKingtext 10/9/06 7:02 AM Page 42

H. A. KING

44

7000 SERIES ISOLATORSSHEAR MOUNTS

Studs & Nuts: Interchangeable

Stud Lengths: Variable

Threads: Standard or Metric

Spring Rates: 150 - 500 Lbs/In

Studs & Nuts: Interchangeable

Stud Lengths: Variable

Threads: Standard or Metric

Spring Rates: 400 - 1500 Lbs/In

7050

7100

4.00Dia.

3.00Max.2.00 Min.

3.12Dia.

2.25Max.1.50 Min.

4.70

55053_HAKingtext 10/9/06 7:02 AM Page 43

H. A. KING

45

7000 SERIES ISOLATORSSHEAR MOUNTS

Studs & Nuts: Interchangeable

Stud Lengths: Variable

Threads: Standard or Metric

Spring Rates: 400 - 1500 Lbs/In

Studs & Nuts: Interchangeable

Stud Lengths: Variable

Threads: Standard or Metric

Spring Rates: 300 - 800 Lbs/In

Studs Only

Stud Lengths: Variable

Threads: Standard or Metric

Spring Rates: 600 - 1200 Lbs/In

7150

7200

7250

2.75Max.1.50 Min.

3.75SQ.

4.82SQ.

4.78 3.831.75

2.56

2.81

3.08

2.25

6.75 5.88 3.81

1.502.52

.252.52

4.06Dia..

55053_HAKingtext 10/9/06 7:02 AM Page 44

H. A. KING

46

7000 SERIES ISOLATORSSHEAR MOUNTS

Nuts Only

Threads: Standard orMetric

Spring Rates:1200 - 2400 Lbs/In

7300

7350

7400

Nuts Only

Threads: Standard orMetric

Spring Rates:1200 - 2400 Lbs/In

Studs Only

Threads: Standard orMetric

Spring Rates:600 - 1400 Lbs/In

2.625 SQ.

4.75SQ.

5.12SQ.

2.12

5.12

6.424.75

2.12

7.66

5.75SQ. 5.72

4.00 Dia.B.C.

7.00SQ.

2.25

2.625

55053_HAKingtext 10/9/06 7:02 AM Page 45

H. A. KING

47

7000 SERIES ISOLATORSSHEAR MOUNTS

Nuts Only

Threads: Standard orMetric

Spring Rates:1500 - 3000 Lbs/In

7450

7500

7550

Nuts Only

Threads: Standard orMetric

Spring Rates:2500 - 4300 Lbs/In

Studs Only

Threads: Standard orMetric

Spring Rates:900 - 3000 Lbs/In

5.25

7.25

2.15

2.25 Max.2.00 Min.

2.50 Max.2.225 Min.

7.38

4.00

7.00

3.00

6.00

6.30

4.00

7.125

8.50

3.50

4.00

4.00

12.07

10.38

4.00

8.53

55053_HAKingtext 10/9/06 7:02 AM Page 46

H. A. KING

48

7000 SERIES ISOLATORSSHEAR MOUNTS

7600

Studs & Nuts:Interchangeable

Studs Length: Variable

Threads: Standard orMetric

Spring Rates:900 - 3000 Lbs/In

7.14

5.50

4.00

7.123.88

2.50

9.00

55053_HAKingtext 10/9/06 7:03 AM Page 47

Spring Rates:500 - 1300 Lbs/In

7650 5.75SQ.

3.00

7.12SQ.

.51

7610

1.4810.48

R0.56

4.81

1.31

Spring Rates: 1100 - 2000 LBS/In

12.00

O 1.004 Places

H. A. KING

49

7000 SERIES ISOLATORSSHEAR MOUNTS

7700

Spring Rates:1100 - 2000 Lbs/In

7.50SQ.

9.00SQ.

.51

4.00

7750

7800

Spring Rates:240 - 800 Lbs/In

Nuts Only

Threads: Standard orMetric

Spring Rates:600 - 1200 Lbs/In

3.9SQ. 2.49

5.2SQ.

5.0SQ.

6.25SQ.

4.31

H. A. KING

50

7000 SERIES ISOLATORSSHEAR MOUNTS

7850

2.5

Spring Rates:300 - 900 Lbs/In

55053_HAKingtext 10/9/06 7:03 AM Page 48

7900

Nuts Only

Threads: Standard orMetric

Spring Rates:350 - 1000 Lbs/In

5.25

6.38

2.50

3.00

.41DIA.

1.75

2.25

.504.25

H. A. KING

51

ENGINE AND POWER TRAIN MOUNTS

FRONTMOUNT

REARMOUNT

MILITARYVEHICLES

CONSTRUCTIONEQUIPMENT

MEDIUM and HEAVY DUTY TRUCKS

TRANSITMIXERS

55053_HAKingtext 10/9/06 7:03 AM Page 50

H. A. KING

52

8000 SERIES ISOLATORSENGINE MOUNTS

8100

8200

8150

8250

Pilot bushing to relieve lateralstress's on mounting bolt

Metal surfaces to control move-ment in the FOR, AFT, and lat-eral

Elimination of stress and exces-sive wear on rubber surfacesthrough use of metal plates onall contact surfaces

Control torque reactions

Ease of location via pilot flangeinto mounting bracket

Designed to incorporate spacerto achieve correct preloadinstallation

Pilot bushing to relieve lateralstress's on mounting bolt

Elimination of stress andexcessive wear on rubbersurfaces through use of metalplates on all contact surfaces

Control torque reactions

Ease of location via pilot flangeinto mounting bracket

Designed to incorporate spacerto achieve correct preloadinstallation

Rear Engine Mount 4.56

Rear Engine Snubber

Front Engine Mount

Front Engine Snubber

3.38

1.94

.969 Dia.

3.03

.656

1.06

3.06 1.53 1.63

.594

1.56

1.25

4.755.94

1.18

1.00

2.44 2.56

.594

.67 DIA.

.91Dia.

2.75

1.13

55053_HAKingtext 10/9/06 7:03 AM Page 51

H. A. KING

53

8000 SERIES ISOLATORSENGINE MOUNTS

8300Front Engine Mount

Metal cup to control lateralmovement and providesuperior load capacity

Spacer incorporated in mount

Elimination of stress andexcessive wear on rubbersurfaces through use of metalplates on all contact surfaces

1.61 DIA.2.50 DIA.

2.94 DIA.

.52 DIA.

1.31.75

55053_HAKingtext 10/9/06 7:03 AM Page 52

H. A. KING

54

ENGINE MOUNTING FORVIBRATION AND NOISE CONTROL

The engine is one of the major causes of vibrationaldisturbances in an on-or-off-highway vehicle. The on-or-off-highway vehicle, being a complex network ofstructural members and mechanical, electrical andelectronic components, is very susceptible to the dam-aging effects of vibrational disturbances. Isolating theengine can help to eliminate thesedamaging inputs.

An engine coupled directly to a support structure hasa direct path for the transmission of vibration andnoise. These vibrational and noise inputs are damag-ing to the structure and equipment of the cab and cre-ate a poor environment for the operator. Othermechanical, electrical and electronic components with-in the vehicle can also suffer a loss in operation effi-ciencies and service life due to these inputs.

The use of a properly designed resilient element tomount the engine to the support structure will reducethe transmitted vibrations and sever the noise paths.This resilient coupling results in a smoother and qui-eter environment for the operator. Additional benefitsare added fatigue life for components, accessoriesand structural fasteners.

The information required of the designer is simply adescription of the engine and its operating characteris-tics. With only the information obtained from theanalysis form presented on the reverse, the H.A. kingdesign team can make isolator recommendations tosolve even the most troublesome engine isolation pro-jects.

Please Return To:

5038 LeafdaleRoyal Oak, Mi 48073

Phone: (248) 280-0006Fax: (248) 280-1510

H. A. KING

Name

Title

Company

Address

City State Zip

Phone Fax

Date Reply Required

55053_HAKingtext 10/9/06 7:03 AM Page 53

H. A. KING

55

ENGINE MOUNTING FORVIBRATION AND NOISE CONTROL

DATA REQUIRED FOR ENGINE ANALYSIS

Engine Manufacturer and Model

Number of Cylinders Two or Four Stroke Firing Order

Engine Speeds: Idle Operating

Engine Weight (Wet, Including Accessories)

Transmission Manufacturer and Model

Transmission Weight (Wet)

Engine C G. Distance to Front Mount....................................................... X1=

Engine C.G. Distance to Rear Face of Engine Block.................................. X2=

Rear Engine Mount Distance to Rear Face of Engine Block.................... X3=

Rear Engine Mount Distance to Front Mount........................................... X4=

Transmission C.G. Distance to Rear Engine Mount.................................. X5=

Tail Stock Mount Distance to Transmission C.G....................................... X6=

Front Mount Height Above/Below CSCL*................................................. Y1=

Engine C.G. Height Above CSCL*............................................................. Y2=

Rear Engine Mount Height Above/Below CSCL*...................................... Y3=

Tail Stock Mount Height Above CSCL*..................................................... Y4=

Transmission C.G. Height Above/Below CSCL*....................................... Y5=

Distance Between Front Mounts (Zero for Single Front Mount)................ Z1=

Distance Between Rear Mounts................................................................ Z2=

Temperature Range: Operating Non-Operating

Comments

*CSCL — Crank Shaft Center Line

Z2

*CSCLZ

Y5

Y4

X6

X3

X5

Y3

X2

X4

Transmission C.G.

Composite C.G.

Rear Face of Engine Block Y

X1

Engine C.G.

Y2

Y1

FrontEngineMount

Z1

Z

TailStockMount

Z

55053_HAKingtext 10/9/06 7:03 AM Page 54

H. A. KING

56

OPERATOR CAB MOUNTINGFOR VIBRATION AND NOISE CONTROL

Vibration and shock inputs to cab of a heavy-dutyvehicle can come from various sources. One ofthe primary vibration sources is the engine Othersources are highway and off-highway vibration andshock inputs which reduce operator efficiencywhile the vehicle is in motion. These multi-sourceinputs are also damaging to the structure andequipment in the cab. Instruments and electroniccomponents can suffer a loss in operation efficien-cies and service life due to these dynamic inputs.

The use of a resilient element to couple the cab tothe frame provides a method to isolate vibrationand reduce noise. This resilient coupling results ina smoother and quieter operating environment.

The information required of the designer is simplya description of the cab's design and performancegoals. With only the information obtained below,the H. A. king design team can make one or moreisolation system recommendations to improve theoperating environment and extend the service lifeof the cab's components.

NameTitleCompanyAddressCityState ZipPhone FaxWeight: Without Operator (lbs.)

With Operator (lbs.)

Moments of Inertia Ix-x

Iy-y

Iz-z

Allowable Sway During ROP SituationsDirection:X

YZ

Disturbing Frequencies (HZ)

Current Noise Level (bd)Desired Noise Level (bd)Date Reply Required

Please Return To:

5038 LeafdaleRoyal Oak, Mi 48073

Phone: (248) 280-0006Fax: (248) 280-1510

H. A. KING

X

Y

Z

CONFIGURATION 1

CONFIGURATION 2

CONFIGURATION 3

Please complete above sketch and encloseyour drawings of frame and a cab attachmentincluding relevant dimensions, CG location,and mounting locations.

55053_HAKingtext 10/9/06 7:03 AM Page 55

H. A. KING

57

TABLES FOR CONVERSIONFROM INCHES INTO MILLIMETERS

55053_HAKingtext 10/9/06 7:03 AM Page 56

Please Return To:

5038 LeafdaleRoyal Oak, Mi 48073

Phone: (248) 280-0006Fax: (248) 280-1510

www.ha-king.com

H. A. KING

Revision 10/06©

55053_HAKing-Covers 10/9/06 1:27 PM Page 2