Measure of internal contamination from electronic componants Use of a technic from nuclear physic to improve detection limits and to identify alpha emitter Guillaume Warot 2011 LSM

Measure of internal contamination from electronic componantsewh.ieee.org/soc/cpmt/presentations/cpmt1110w-2.pdf · secular equillibrium . Radioactives Chains . ... • Non direct

Embed Size (px)

Citation preview

Measure of internal contamination from

electronic componants Use of a technic from nuclear physic to improve detection limits and to identify

alpha emitter

Guillaume Warot 2011 LSM

2 fire-stop door

Laboratory entrance

FRANCE ITALIE

AltitudesDistances

1228 m 1298 m1263 m0 m 6210 m 12 868 m

Tunnel Routier du Fréjus LSM

Guillaume Warot 2011 LSM

For the rare event experiments this background is too important for the experiment to be settled at the surface

Montain stop most of them This is the deepest lab in europe the 1700 m of the rock overburden reduce By a million factor this cosmic ray flux

Mais pourquoi un laboratoire souterrain ??

Fréjus

Modane

Entrée du tunnel routier

first goal Protection against cosmic rays

Guillaume Warot 2011 LSM

• Neutron background due to self fission from U Th – Flux mesured in different location in the

laboratory. • Radon in air

– Radonless air in critical location. – Continuous monitoring in the laboratory.

Caracterisation of background

Guillaume Warot 2011

NEMO neutrino ettore majorana experiment

double bêta decay

neutrino mass ???

neutrino = antineutrino ???

Dirac’s Neutrino :

Majorana’s Neutrino : ν ≠ ν ν = ν

Guillaume Warot 2011 LSM

~ 2000 PM tubes

6 m

3 m

X 20 modules

40 000 wires

Sources = 10kg 100Mo, 82Se, …

surface = 20 m2

Plastic scintilliator

Mixture Helium – alcool

30 m3

NEMO 3 ββ expt with 100Mo

Guillaume Warot 2011 LSM

EDELWEISS II • Goal : Discovering Dark matter anomalous rotation speed

• Germaniums detectors cooled down to 20mK

Guillaume Warot 2011 LSM

EDELWEISS II

Cristal de Germanium

WIMP

NTD (t°)

Electrodes

heat

ionisation

Energie de recul

Electron

Guillaume Warot 2011 LSM

Natural radioactivity

• There are different kind of radioactovity. Alpha decay is the only constraint for electronic

• α Particles have an important LET so they can ionise matter enough to perturbate electronic device

Desintegration rate

Élément T1/2 (s) Abundance (%)

Désintégrations/bilions of d'hours

(pour un volume 250 µm x 1 cm²)

147Sm 3.34x1018 15 1.40x1014

190Pt 2.05x1019 0.014 2.13x1010

144Nd 7.23x1022 23.8 1.03x1010

152Gd 3.41x1021 0.2 1.94x109

148Sm 2.21 x1023 11.24 1.59x109

187Re 1.37 x1018 62.6 1.43x109

186Os 6.31 x1022 1.59 7.86x109

174Hf 6.31 x1022 0.16 7.91x108

238U (1ppb) 1.41x1017 99.2742 2.20x107

232Th (1ppb) 4.43x1017 100 7.04x106

Neut ron

0,6 réaction/jour = 2.50x107 /milliard heures

Desintegration rate • Material : desintegration rate are very high because they

don’t take into account the mass used in the final application

These rates show that to an equal volume there will more alpha decays than nuclear reaction induced by neutrons

• Impureties : rates are higher because therre is a whole

chain the main challenge is to measure the breaks in the secular equillibrium

Radioactives Chains

Guillaume Warot 2011 LSM

• Radioactivity is measured in Becquerels • 1Bq = one decay per second • For an alpha emitter 1 alpha per second • Secular equilibrium break means that U/Th

activity is different from its daughter

Radioactives Chains

Guillaume Warot 2011 LSM

• Secular equilibrium is broken by chemical operation which depends on properties of elements

• It is reached after 10 half lives of the daughter

• At the timescale of a component it could be broken for these nuclides

Equilibrium breaks

Guillaume Warot 2011 LSM

Equilibrium breaks

• Measuring U/Th => measuring radioactive contamination

• Measure radioactivity in becquerel – Conversion mass-becquerel – 1ppb 238U= 12mBq/kg – 1ppb 232Th=10-6g/kg= 3.1mBq/kg – 1Bq/kg 226Ra= 2.7 *10-11g/kg =27 pps – 1Bq/kg 210Pb= 3.7 *10-13g/kg

Equilibrium breaks

Guillaume Warot 2011 LSM

• Examples : measure Al/Mg/Si 98/1/1 Goodfellow 5N

• 1Bq / kg of Uranium but no daughters • High purity products • Low radioactives products

Equilibrium breaks

Guillaume Warot 2011 LSM

• Radon issues • External source of contaminations • 220Rn 55s 3α low contamination • 222Rn 3.66j 3α and radioactives daughters • Penetration through plastics • Daugther implantation

Equilibrium breaks

Guillaume Warot 2011 LSM

• Base of the law background experiment • 20 years of optimisation at LSM • Various application:

– Élément de structure des expériences bas bruit (CENBG,LSM,EDELWEISS)

– Surveillance environnementale(IRSN,DASE) – Datation d’objet(LSCE,LSM,CENBG) – Identification de provenance(LSCE)

Gamma ray measurment

Guillaume Warot 2011 LSM

• Collaboration with iRoC • benchmark alpha-gamma performed • Global alpha measurement • Gamma ray measurment of the same

sample

Gamma ray measurement

Guillaume Warot 2011 LSM

Gamma ray measurement

• Alpha emission: 2,40 ± 0.06±0.05 • iRoC counting (2.4 ± 0.5)

Knowledge of low background radioacivity

Possibility to measure low level of

radioactivity with HPGe

Simulation GEANT 4 of alpha emitted

Measure of radioelement in

Becquerel

Gamma spectra

Guillaume Warot 2011 LSM

• Improving the detection limit • Main advantage

– Low background : • 6 count per hour in 15-1500keV • Energy resolution 900 eV • Detection limits about 1 mBq/kg for ten days 50g • Testing the vlume not the surface • Radionuclide identification • Simulation more accurate introducing energy emitted

Gamma ray measurement

Guillaume Warot 2011 LSM

• disadvantage: – Isotopes without gamma rays

»Possibility to measure mother or daughter and use secular equilibrium

– Simulation needed for alpha emission measurement

Gamma ray measurement

Guillaume Warot 2011 LSM

• Disadvantage • Underground lab and radonless to reach

low level of radioactivity • Non direct results • Usefull for volumic samples

Gamma ray measurement

Guillaume Warot 2011 LSM

• Volumic samples not surface only • Detection limits about 1 mBq/kg for 10 days for

50g 10-4 α/cm2.h • Proposed in R.J. McDonald & al « low level

measurment of alpha emitting Nuclei in Ceramics and Lead » Journal of radioanalytical and Nuclear chemistry , Vol 233 No1-2 1998, p185-189

• Determination around 0.1 ppb for U/Th

Gamma ray measurement

Guillaume Warot 2011 LSM

• Simulations nucleus by nucleus • Simulation changing the sample shape • No need for flat samples • Allow to dismantle chip and make

benchmark after use

Gamma ray measurement

Guillaume Warot 2011 LSM

• Need of recognition • Need chip tests • Possibility to dismantle • Measure of different layer • Simulation of the number of error • Accelerated test with source

Gamma ray measurement

Guillaume Warot 2011 LSM

• Fisson Product = Bêta emitter • Transuranien products • 0,3Bq / kg Pu on vegetables from Sendai

market • France Cs/I/Ba/La/Te • Nd métal coming from japan

Fukushima

Guillaume Warot 2011 LSM

• Conclusion

• Less sensitivity for surface contamination during manipulation • Reconstruction of the final emission by simulation • Possibility to use different kind of samples and the • Hypothesis on secular equilibrium or coupling with radiochemistry

and ICP-MS • Simulation of alpha emitted to have the energy dependance • Max sample size 196mm

• Contact : [email protected]

Guillaume Warot 2011 LSM