Carbon Dioxide Isotope Analyzer - Elevated CO2
LGR’s new “Carbon Dioxide Isotope Analyzer
- Elevated CO2“ provides many features that
researchers need when measuring isotopic
carbon dioxide from samples containing high
levels of CO2 including:
• LGR’sEnhancedPerformancepackage
provides ultra-low drift and high precision
• AbilitytomeasureCO2 as well as δ13C and
δ18O in CO2 from 2% to 100% CO
2
• Abilitytoanalyzeacidifiedcarbonates
• Abilitytoanalyzebreath(human,mice)
The stable isotope composition of carbonate
mineralshasbeenofinterestfordecades,with
initial research focusing on measurements of
carbonates in the ocean for paleoceanography
applications. Stable isotope studies of
carbonates have also been used extensively
toexploretheroleoffluid-rockreaction
and geosphere-hydrosphere-atmosphere
interactions in the earth and environmental
sciences.Todate,conventionalanalyses
involveacidificationofacarbonatesample
to produce CO2,followedbymeasurements
withIRMS.Whileeffective,IRMSrequiresa
trainedoperator,isexpensive,andcannotbe
performedinthefield.
LGR’s new “Carbon Dioxide Isotope Analyzer
- Elevated CO2“ provides measurements of
δ13C and δ18O as well as mixing ratios of13CO
2,12CO
2,and12C18O16O in gas samples
with high precision in measurement times
oflessthanaminuteinaneasy-to-use,field
portable unit. Due to its inherently fast time
response,theinstrumentprovidesδ13C and
δ18O measurements over a wide range of
even when CO2 values change rapidly as often
happensduringfieldstudies.
The new Analyzer meets all of the needs for
effective measurements of isotopic carbon
dioxide,including:(1)accuratemeasurements
overawiderangeofmolefractions,(2)high
precision,(3)abilitytoreportreliablevalues
evenifmixingratiosarerapidlychanging,
(4) portability(lowpower),(5)user-friendly
interface,(6)lowdrift/highstability.
Inaddition,theavailabilityofmanyvalue-added
options extends the abilities of the unit to
includediscretesamples(collectedinbagsor
vials,forexample)andtoautomaticallyhandle
multiple inlet sources.
The Analyzer uses LGR’s patented Off-axis ICOS
technology,afourth-generationcavityenhanced
absorptiontechnique.Off-axisICOShasmany
advantages over conventional Cavity Ringdown
Spectroscopy(CRDS)techniquessuchasbeing
morerobustmechanicallyandthermally,having
amuchshortermeasurementtime,andnot
requiringexpensiveandpowerconsuming
auxiliarycomponents.Asaresult,LGR
instrumentsprovideunsurpassedperformance,
durability and ease of use.
Features and Benefits
• Measuresδ13C,δ18O,12C16O2,
13C16O2,12C18O16O at 1 Hz
• 12CO2,13CO
2,andC18OO
from 2%
to 100% CO2
• Analysisofcarbonateminerals
• Analysisofbreath(mice,humans)
• Simultaneousmeasurementsofallgases provides maximum accuracyeven when CO
2 levels vary rapidly
• High-resolutionabsorptionspectraare viewable for real-time diagnostics
• Lowpower:idealforfieldapps
• EnhancedPerformancepackageprovidesunprecedentedstability,precision and low drift.
• (Option)Manualinjectionofdiscrete gas samples
Measure δ13C and δ18Oin samples with elevated CO
2 levels
Precisely.
Performance Specifications
Precision (1s, 100 sec):δ13C: 0.2‰δ18O: 0.6‰C16O
2: 20 ppm
Measurement Rates:All parameters measured simultaneously at rates up to 1 Hz
Measurement Range (meets all specs):CO
2 :2%–100%(benchtoppackage;model912-0021)
CO2 :4%–100%(rackmountpackage;model911-0021)
Operational RangeCO
2 : 0 – 100%
Max Drift at STP (1s, 1 hr average over 24 hours):δ13C:<0.5‰
Sampling Conditions:SampleTemperature:-20–50°COperatingTemperature:0–45°CAmbientHumidity:non-condensing(0-100%RH)
Outputs:digital(RS232),Ethernet,USB
Power Requirements:115/230VAC,50/60Hz165W
Dimensions:11”×38”×22”(benchtoppackage)14”×19”×24”(rackmountpackage)
Weight:50kg(benchtoppackage)40kg(rackmountpackage)
Ordering Information
Part Number:CCIA1-912 (EP Benchtop, GLA431 Series)CCIA1-911 (EP Rackmount, GLA331 Series)
Accessories and OptionsMIU-16:MultiportInletUnit–automated16-portmultiplexer
MIU-8: MultiportInletUnit–automated8-portmultiplexer
ACC-DP20: 3-head vacuum pump – for flow-through time <2 sec
OPT-BATCH-INJECTION: Syringe Injection – Allows measurements of discrete samples via manual injection
Carbon Dioxide Isotope Analyzer - Elevated CO2
Tel: +1 800 858 3847 (North America)Tel: +1 418 877 2944 (Worldwide)Fax: +1 418 877 2834 [email protected] www.lgrinc.com
—ABB Inc.Measurement & Analytics3400, rue Pierre-Ardouin Quebec, (Quebec) G1P 0B2 Canada
Instrumentcomplieswith21CFR1040.10and1040.11