3
Rf-Technologies nv - Lange Ambachtstraat 40 - 9860 Oosterzele - Belgium - Tel +32 9 362 31 71 - Fax +32 9 362 33 07 - www.rft.be - [email protected] ME MANF K107-C 05/2012 Rearmation motor for MANF + MANF EVO

ME MANF - RFT · ATTENTION: An electromagnet (VM) needs power supply for rearmation. Motorized unlocking: 1. Switch off the power supply for at least 10 sec. 2. Supply the actuator

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ME MANF - RFT · ATTENTION: An electromagnet (VM) needs power supply for rearmation. Motorized unlocking: 1. Switch off the power supply for at least 10 sec. 2. Supply the actuator

Rf-Technologies nv - Lange Ambachtstraat 40 - 9860 Oosterzele - Belgium - Tel +32 9 362 31 71 - Fax +32 9 362 33 07 - www.rft.be - [email protected]

ME MANF

K

10

7-C

05

/20

12

Rearmation motor for MANF + MANF EVO

Page 2: ME MANF - RFT · ATTENTION: An electromagnet (VM) needs power supply for rearmation. Motorized unlocking: 1. Switch off the power supply for at least 10 sec. 2. Supply the actuator

ME MANF Rearmation motor for MANF (EVO)K107 - C

05/2012

2

PRODUCT PRESENTATION

The electric rearmation motor arms the smoke evacuation damper by remote control. When the rearmation motor is set under current, the mechanisms main axis moves the operation lever till the damper blade arrives in its stand-by position (closed).

LIST OF PARTS

Description Characteristics Number

Rearmation motor ME 1

Fastening screws DIN 7985 M5x6 2

Lock washer DIN 6798 M5 2

Label 'KIT' (yellow) ETIK-D042 1

DETAILED CHARACTERISTICS

ME MANF (EVO)

Power supply 24VDC/24VAC/48VDC/48VDC

Power consumption 24V: Pmax=20W / 48V: Pmax=40WRunning time motor <30sNoise level motor Max. 50dB[A]Maintenance Maintenance freeAmbient temperature -30°C until 50°C

ELECTRICAL WIRING DIAGRAM

Fig. MANF (EVO) (+ ME)

DCU

121110

FCB

NONFC

15 161413

DCB

NONFC

9875 6

FCU

NONFCNONFC

3

-

-

+

+

4

ME

1

-+

2

24/48 VDC +/- 10%24/48 VAC +/- 10%

24 VDC 48 VDC

• ME: Rearmation motor

• DCU: Unipolar beginning of range switch

• FCU: Unipolar end of range switch

• DCB: Bipolar end of range switch (option)

• DCB: Bipolar beginning of range switch (option)

APPLICATIONS MANF (EVO)

fig. VR2 fig. VU2

Page 3: ME MANF - RFT · ATTENTION: An electromagnet (VM) needs power supply for rearmation. Motorized unlocking: 1. Switch off the power supply for at least 10 sec. 2. Supply the actuator

3

ME MANF Rearmation motor for MANF (EVO)K107 - C 05/2012

OPERATION MANF (EVO)

MANF (EVO)

Manual rearmation: Turn 90° with a Torcq key 13 mm (1)ATTENTION: An electromagnet (VM) needs power supply for rearmation.

Motorized unlocking: 1. Switch off the power supply for at least 10 sec.2. Supply the actuator for at least 30sec. (respect the prescribed voltage). 3. The rearmation stops automatically:

- when detecting a torque > 20 Nm - ! Switch off the power supply after rearmation ! Switch off the power supply for at least 15 sec. in between each rearmation cycle.

Manual unlocking:Use the unlocking button (2)

Remote controlled unlocking:By sending an electrical impulse (VD) or by interrupting the power supply (VM) to the magnet.

MOUNTING AND DISMANTLING

Dismantling of the motor

Mounting of the motor

1. Unlock the mechanism. 2. Remove cover.3. Disconnect electric wires.

4. Remove protection cover. 5. Remove the current motor

Fig. MANF (EVO)

1

2

Fig. MANF (EVO)

1

2

8. Connect motor and magnet to the print.9. Connect all electric wires. 10. Place cover.

6. Mount the rearmation motor.

7. Place protection cover. 11. Test the good functioning of the mechanism.12. Apply the label 'KIT' and fi ll in the necessary information.

If the damper is manipulated in any other way than described in this manual, Rf-Technologies will decline any responsibility and the guarantee will immediately expire!