4
Featuring Proton ® PEM Advanced Water Electrolysis Technology number one by nature MC100/MC200/MC400 Containerized Hydrogen Plants

MC100/MC200/MC400 Containerized Hydrogen Plants · times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs. Nel Hydrogen

  • Upload
    others

  • View
    8

  • Download
    1

Embed Size (px)

Citation preview

Page 1: MC100/MC200/MC400 Containerized Hydrogen Plants · times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs. Nel Hydrogen

Featuring Proton® PEM Advanced Water Electrolysis Technology

number one by nature™

MC100/MC200/MC400 Containerized Hydrogen Plants

Page 2: MC100/MC200/MC400 Containerized Hydrogen Plants · times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs. Nel Hydrogen

The Proton Exchange Membrane (PEM) Hydrogen PlantNel Hydrogen Proton® PEM water electrolysers are designed to meet the specific needs of energy storage, fueling stations and high purity industrial applications. These state-of-the-art units offer turnkey solutions for the growing need for stable, cost-effective, high volume hydrogen supply.

Large Scale Hydrogen PlantsLarge scale renewable energy storage, grid management or industrial applications that demand fast response times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs.

Nel Hydrogen is the acknowledged expert in large scale electrolysers. The MC100, MC200 and MC400 containerized platforms enable flexible plant configurations and installations for medium to large scale hydrogen plants based on water electrolysis technology.

The units provide fast response times and production flexibility making them ideal for hydrogen generation utilizing renewable power sources. The MC100, MC200 and MC400 with Proton PEM Technology make for reliable and turnkey solutions with minimal maintenance.

Typical applications include: • Renewable energy storage • Industrial process gas • Hydrogen fueling

Representative view of MC400 – installation may vary.

Page 3: MC100/MC200/MC400 Containerized Hydrogen Plants · times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs. Nel Hydrogen

Electrolysis is the process of splitting the water molecule into hydrogen and oxygen using electricity.The inputs to this process are simply feed water and the current supplied to the electrolyser.

MODEL MC100 MC200 MC400

Class 0.5 MW 1.0 MW 2.0 MW

Description

Fully-automated MW-class on-site hydrogen generator utilizing a modular skid-based designTri-mode operation (selectable):• Command-following mode allows operation based on available input power• Load following mode automatically adjusts output 0-100% to match demand • Tank filling mode operates with power-conservation mode during standby

Electrolyte Proton Exchange Membrane (PEM) – Caustic-Free

HYDROGEN PRODUCTION

Net Production RateNm3/h @ 0°C, 1 barSCF/h @ 70°F, 1 atmSLPM @ 70°F, 1 atmkg/24 h

103 Nm3/h3,909 SCF/h1,845 SLPM222 kg/24 h

207 Nm3/h7,857 SCF/h3,708 SLPM446 kg/24 h

413 Nm3/h15,714 SCF/h7,416 SLPM892 kg/24 h

Delivery Pressure – Nominal 30 barg (435 psig); full differential pressure H2 over O2

Average Power Consumption at Stack per Volume of H2 Gas Produced1 4.53 kWh/Nm3

Average Power Consumed at Stack per Mass of H2 Gas1 50.33 kWh/kg

Purity (Concentration of Impurities)

Purity (Concentration of Impurities with Optional High Purity Dryer)

99.9% [H2O < 500 ppm, N2 < 2 ppm, O2 < 1 ppm, all others undetectable]

ISO 14687-1:1999 Type 1 Grade C / ISO 14687-2:2012 Type 1 Grade D99.9998% [H2O < 2 ppm, N2 < 2 ppm, O2 < 1 ppm, all others undetectable]

Start-Up Time (from Off State) <5 min

Ramp-Up Time (Minimum to Full Load) <10 Sec

Ramp Rate (% of Full-Scale) ≥ 15% per sec (Power Input Mode)

Turndown Range 10-100% (Input Power Mode); 0-100% (H2 Demand Mode)

DI WATER REQUIREMENT

Consumption Rate at Maximum Production 93 L/h (25 gal/h) 187 L/h (49 gal/h) 373 L/h (99 gal/h)

Temperature 5°C to 40°C (41°F to 104°F)

Input Water Quality Required: ASTM Type II Deionized Water, < 1 µS/cm (> 1 MΩ-cm) Preferred: ASTM Type I Deionized Water, < 0.1 µS/cm (> 10 MΩ-cm)

Page 4: MC100/MC200/MC400 Containerized Hydrogen Plants · times or compressor-less operation should consider our Proton PEM hydrogen plants for their hydrogen production needs. Nel Hydrogen

1. Dependent on configuration and operating conditions. 2. Requires access restriction and cover – site and configuration specific. 3. Plus vent and rooftop equipment, site specific – add 5 m (16.5’) to height.

PD-0600-0135 Rev A© 2019 Nel ASA. All Rights Reserved. Nel, number one by nature, Proton, and the Nel and Proton logos are trademarks of Nel ASA or its subsidiaries.

www.nelhydrogen.com | +1.203.949.8697 | [email protected] MADE IN USA

Certified to ISO 9001:2015

For reference only – specifications are subject to change. Please contact Nel Hydrogen for solutions to best fit your needs.

Representative views of MC400 – installation may vary.

MODEL MC100 MC200 MC400

ELECTRICAL SPECIFICATIONS

Electrical Requirements

Typical installation: 10 kV and 20 kV, three phase + Neutral, 50Hz/60Hz; for lower voltage connection, consult Nel Hydrogen Applications Engineering

Department for specific requirements and optionsAncillary equipment powered by customer or optionally powered by Nel Hydrogen

Power Quality Designed to German TAB specification

PHYSICAL CHARACTERISTICS

Rectifier Transformer Area2 W x D x H

3.5 m x 3 m x 3 m (11.5’ x 9.8’ x 9.8’)

3.5 m x 3 m x 3 m (11.5’ x 9.8’ x 9.8’)

4 m x 3.5 m x 3.5 m (13.2’ x 11.5’ x 11.25’)

Electrolyser Container Dimensions3 W x D x H

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

Power Supply Container Dimensions3 W x D x H

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

12.2 m x 2.5 m x 3 m (40’ x 8’ x 9.9’)

ENVIRONMENTAL CONSIDERATIONS – DO NOT FREEZE

Standard Siting Location Outdoor, cover required for high dust or snow load areas

Flatness 35/25 per ACI-117-10Bottom access for AC and DC electrical connections

Storage/Transport Temperature 5°C to 60°C (41°F to 140°F)

Ambient Temperature Range 5°C to 40°C (41°F to 104°F)

Altitude Range-Sea Level 1,000 m (3,281 ft)

OPTIONS

• Factory matched RO/DI water system • Factory matched thermal control unit• Dew point monitoring (requires dryer option)

• High purity hydrogen dryer • Air compressor • Low ambient temperature package (-20°C)