INERT GAS GLOVEBOX WORKSTATION
www.mbraun.com
I
N E R T G A S
T E C H N O L
O G Y
• Compact design with integrated purifer unit
• Stainless steel enclosure with polycarbonate window
• Removal of oxygen and moisture, <1 ppm• PLC-M. Braun controller with large color touch panel
• Large antechamber with sliding tray
• Closed loop recirculation
• Negative and/or positive pressure operation
• Foot pedal switch for temporary pressure adjustment
• ECO Mode operation feature available
• Optional control and safety features available
LABstar
S p r e
a d b y J S © M . B r a u n I n e r t g a s - S y s t e m e G m b H • S u b j e c t
t o b e c h a n g e d w i t h o u t n o t i c e !
B R 0 4 / V 3
7/21/2019 MB LABstar Glovebox
http://slidepdf.com/reader/full/mb-labstar-glovebox 2/4
Internal solvent vapor removal
Microscopes
Freezer
Feedthroughs
Oxygen, moisture, andsolvent sensor
External solvent vapor removal
Mini-antechamber Additional accessories available
LABstar Gloveboxes and accessories
GLOVEBOX TECHNICAL DATA:
MAIN ANTECHAMBER TECHNICAL DATA:
Type of construction.....................Side panels bolted on the box body
Material........................................Stainless steel (US 304, 1.4301)
Inside lengths...............................1200 / 1450 / 1950 mm
Inside depth.................................780 mm
Inside height.................................920 mm
Leak rate......................................< 0.05 Vol%/h
Inside surface...............................Brushed nish Ra < 1µm
Outside surface............................Coated, white (RAL 9003)
Window.........................................Scratch resistant polycarbonate window
Glove ports...................................POM, 220 mm diameter, O-ring sealed
Gloves..........................................Butyl, thickness 0,4 mm
Light.............................................Fluorescent lampFeedthroughs...............................2 / 3 / 4 DN40KF anges (depending on box length)
Electrical feedthrough..................1
Dust lter......................................HEPA H13 in/out
Shelves………………….............. 3 modular shelves (length: depending on box length)
Optional:
• Cold well
• Safety glass window
• Large choice of feedthroughs for signals, gas, liquids
• A variety of gloves (Hypalon, Neoprene and Butyl) and
thickness sizes are available
• Specifc shelves and storage arrangements....
Optional:
• Time controlled antechamber operation
• Round large main antechambers
• Round mini antechambers (side or bottom mounted)
• Rectangular square antechamber
• L-shaped square antechamber
• Round T-shaped antechamber • Square T-shaped antechamber...
Type.............................................Cylindrical
Material........................................Stainless steel
Dimensions.................................. 390 x 600 mm (D x L)
Inside surface...............................Brushed nish
Outside surface............................Coated, white (RAL 9003)
Leak rate......................................< 10E-5 mbar l/s
Sliding tray................................... Stainless steel
Dimensions of sliding tray............ 575 x 290 mm (L x W)
Doors............................................Aluminum , anodized, thickness 10 mmDoor lock......................................Door closing mechanism with spindle handle for one
hand operation
Pressure gauge............................Analog display
Vaccum / Rell process............... Manual operation via hand valves
Valves...........................................Hand valves (DN40 vacuum line / DN8 rell line)
7/21/2019 MB LABstar Glovebox
http://slidepdf.com/reader/full/mb-labstar-glovebox 3/4
*Technical note: Depending upon operating conditions
PLC-M. Braun controller with large color touch screen
Gas Inlet
Encapsulated Blower Gas Outlet
Reactor Column
Gas purifer unit LABstar
GAS PURIFIER UNIT TECHNICAL DATA:
Operation principle.........................................Closed loop recirculation
Attainable purity level.....................................Moisture < 1 ppm, Oxygen < 1 ppm
Recommended enclosure volume..................Up to 2 m³
Number of purication lines per purier..........1
Number of reactor columns per line...............1
Number of reactor columns per purier..........1
Reactor capacity per purication line*
(O2) Oxygen..................................20 l
(H2O) Moisture..............................900 g
Regeneration.................................................. Automatic regeneration sequence
Control unit.....................................................PLC - M. Braun
Display............................................................Large color touch panelBox pressure control......................................Automatic pressure control with foot switch (± 15mbar)
Vacuum pump*...............................................Rotary vane pump with 17 m³/h (10 CFM)
Blower (50 Hz / 60 Hz)*................................. Variable speed up to 22 m³/h
Main and side piping......................................Stainless steel 1.4301 (SUS 304)
Main and control valves..................................Electro-pneumatic
Regeneration gas...........................................N2/H2 mix. or Ar/H2 mix. (H2 2-10 %)
Working gas................................................... Nitrogen, Argon or Helium
Size................................................................472 mm x 459 mm x 705 mm (L x W x H)
Optional feature..............................................Moisture and oxygen analyzer
Optional feature..............................................ECO Mode
Optional feature..............................................Solvent vapor removal
Optional feature..............................................Dry pump upgrade
Optional feature w/ MBRAUN glovebox......... Box Purge function
Optional feature w/ MBRAUN glovebox......... Antechamber automatic (time controlled)
Optional feature w/ MBRAUN glovebox......... Freezer
The ECO mode option is designed toreduce noise emission and reduce powerconsumption up to 90%*.
Mode operation
7/21/2019 MB LABstar Glovebox
http://slidepdf.com/reader/full/mb-labstar-glovebox 4/4
1109
1 9 5 6
www.mbraun.com
Weight: 325 kg
Sizes and confguration
Weight: 360 kg Weight: 460 kg
Side view
Dimensions in mm
1956
LAB
2709
LAB
2206
LAB
LABstar
M. Braun Inertgas-Systeme GmbH (Headquarters)Dieselstr. 31 • D-85748 Garching • GermanyPhone: +49 89 32669-0 • Fax: +49 89 32669-105 • E-Mail Sales: [email protected] • E-Mail Service: [email protected]
VOLUMES:
Box length: 1200 mm........................0,8 m³
Box length: 1450 mm........................1,0 m³
Box length: 1950 mm........................1,3 m³
UTILITIES:
Medium (or type) Pressure Flow rate Connection
Working gas Nitrogen, Argon or Helium 6 bars 250 l/min Swagelok Ø 10 mm
Regeneration gas N2/H2 mix. or Ar/H2 mix. (H2 2-10 %) 0.3 - 0.4 bars 10-20 l/min Swagelok Ø 10 mm
Regeneration gas exhaust Flexible hose, 9 x 3mm
Vacuum pump exhaust Depressurized exible hose ,diameter not less than 25 mm (to be supplied by customer)
Electrical power (FLA) 230 V/50-60 Hz, 6 A or 115 V/50-60, 12 A or 100 V/50-60 Hz, 13 A
M. Braun Incorporated14 Marin Way • Stratham, NH • 03885 • USAPhone: +1 (603) 773 9333 • Fax: +1 (603) 773 0008 • E-Mail Sales: [email protected] Service: [email protected]
M. Braun Inertgas Systems (Shanghai) Co., LTDGround oor of building #1 • No. 145 Jintang Road • Tangzhen, Pudong, Shanghai • 201201 • P.R.ChinaPhone: + 86 21 5032 02 57 • Fax: + 86 21 5032 02 29 • E-Mail: [email protected]