MASyUb TayMac Covered Recessed ReceptaclesONE GANG RECEPTACLES
Duplex
GFCI
CATALOGNUMBER
71101
71202
71103
7120471105
7120672101
7220272103722047210572206
DESCRIPTION
Interior (PLASTIC BOX)Exterior (PLASTIC BOX)Interior (METAL BOX)Exterior (METAL BOX)Interior RETROFITExterior RETROFITInterior (PLASTIC BOX)Exterior (PLASTIC BOX)Interior (METAL BOX)Exterior (METAL BOX)Interior RETROFITExterior RETROFIT
UNITCOMPONENTS
S1, A1
S1G,A2S1, A3S1G,A4S1, A5S1G,A5S2, A1
S2G, A2
S2, A3
S2G, A4
S2, A5
S2G, A5
NOTE: For telephone and CATV, the GFCI LEVITONconfiguration is compatible with these Telephone 40649-1, 40649-WLeviton Decora and Eagle Decorator devices: CATV 40681 -I, 40681 -W
EAGLETWD3560, TVD3560
2162V-BOX, 21621-BOX
Leviton and Decora are registeredtrademarks of Leviton Mfg. Co. Eagle
is a registered trademark of EagleElectric Mfg. Co., Inc.
Available in GFCI and Duplex, for interior or exterior
Q) Recommended for interior residential - Includes plastic box and extension ring with shoulder(^ Recommended for exterior residential - Includes plastic box and extension ring without shoulder(m Recommended for interior commercial - Includes metal box and extension ring with shoulder(Q Recommended for exterior commercial - Includes metal box and extension ring without shoulder/& Recommended for retrofit - Includes metal box
Plastic box withnail brackets,plastic extensionring withshoulder
Plastic box withnail brackets,plastic extensionring withoutshoulder
Metal box withflat bracket,plastic extensionring withshoulder
Metal boxwith flat bracket,plastic extensionring withoutshoulder
Metal retrofit box
DuplexGasketsincluded forwet locationinstallation
GFCIGasketsincluded forwet locationinstallation
All MASQUE units available with tumbler lock.
MASQUE units are shipped in Bone unless otherwise specified.After catalog number add "W" for White or "BL" for Blush.
SPECIFICATION GRADETayMac Safety Outlet Enclosures
tSUITABLE FOR WET LOCATIONS WHILE IN USE
The ProblemNot UL Listed For Use In WetLocations With Plug Connected
r,
The TayMac SolutionsStandard Surface Mount MASQUE Covered Recessed
Receptacle Receptacle (Interior Unit Also Available)
COMPLY WITH 1999 NECThe BEST way to assure full compliance with NEC Article 410-57(b)
for receptacles in wet locations is to use the TayMac safety outlet enclosures which are WEATHERPROOF WHILE IN USE.
410-57. Receptacles in Damp or Wet Locations (b) Wet Locations. A receptacle installed in a wet location where theproduct intended to be plugged into it is not attended while in use (e.g., sprinkler system controllers, landscape lighting,
holiday lights, etc.) shall have an enclosure that is weatherproof with the attachment plug cap inserted or removed.
TAYMAC PRODUCT FEATURES:
¥
Design provides rainproof protection WHILE OUTLET IS IN USE.Meets OSHA and NEC requirements while in use.Flame retardant, UV stabilized polycarbonate, non-conductive.Available only through electrical wholesalers.UL listed, tamper resistant.
STANDARD SURFACE MOUNT FEATURES:
Complete with sealing gaskets & stainless steel mounting screws.Battleship grey finish. AVAILABLE WITH CLEAR COVER -ADD LETTER "C" TO CATALOG NUMBER.CSA approved.One gang 47/s" L x 3" W, Two gang 6" L x 47/s" W.Cover depths: Shallow .8', Small 1.3", Standard 2.5", Deep 3.5",Jumbo 5.4", Two gang 3.5".Jumbo covers accommodate up to 10-3 Cord.One gang accommodate up to 12-3 cord.Two gang accommodate up to 8-3 cord.
Individually boxed. Easily painted.NEMA 3R rated while in use.Functional -60° to +200°F.Also available in locking or tumbler key lock.Mounts on either F-S or flush box.
MASQUE RECESSED RECEPTACLE FEATURES:Accommodates 3/s" cord.Cover57/8"Lx33/4"WxV2"D.Available colors: White, Bone and Blush.Suitable for standard 2 x 4 construction.NEMA 1 for interior use. NEMA 3R for exterior use.
(800)526-5416 FAX 1-888-883-2725 www.taymac.com2440 West 12th Street, Suite 5, Tempe, AZ 85281
WTayMacC O R P O R A T I O N
EFFECTIVE 07/00
Specialoptions
available -See inside for details
and ordering information©TayMac Corporation 1993. Patent No. 4,803,307; 4,874,906; 4,986,832. Other Patents Pending. Made in USA.
SPECIFICATIONS SHEET
MASQUE Covered Recessed Receptacles
TYPICALINSTALLATION FORNEW CONSTRUCTION
TYPICALRETROFITINSTALLATION
Suitable for standard 2x4construction
(receptacle not included)4
MASQUE - Wet LocationsSPECIFICATIONS FOR EXTERIOR (WET LOCATION) RECESSED COVEREDSAFETY OUTLET ENCLOSURES General requirements: Receptacles shall beinstalled recessed 2" into wall (i.e. TayMac MASQUE). The receptacle covershall have ports to allow two 3/8" diameter cords to pass through and mustnot protrude over 1/2" from wall surface. Recessed enclosure must have agasket between the enclosure and the mounting surface, and between thecover and sleeve to assure that the enclosure is "Weather proof while in use."The enclosure shall be UL Listed. Enclosure should be manufactured byTayMac Corporation or equal approved by engineer prior to bid.MASQUE - Dry LocationsSPECIFICATIONS FOR INTERIOR (DRY LOCATION) RECESSED COVEREDSAFETY OUTLET ENCLOSURES. General requirements: Receptacles shall beinstalled recessed 2" into wall (i.e. TayMac MASQUE). The receptacle covershall have ports to allow two 3/8" cords to pass through and must notprotrude over 1/2" from wall surface. The enclosure shall be UL Listed.Enclosure should be manufactured by TayMac Corporation or equal approvedby engineer prior to bid.