MASTERFLEXTM
PVC WATERSTOP
BASF Construction Chemicals offices in ASEAN
SingaporeTel :+65-6861-6766Fax :+65-6861-3186
MalaysiaTel :+60-3-3344-3388Fax :+60-3-3344-2288
IndonesiaTel :+62-21-893-4339Fax : +62-21-893-4342
ThailandTel :+66-2204-9427Fax : +66-2664-9267
Vietnam Tel :+84-650-743-100Fax :+84-650-743-200
PhilippinesTel : +63-2-632-9995Fax : +63-2-632-9996
Centrally and externally placed PVC waterstop
DESCRIPTION
Masterflex PVC Waterstop is manufactured with highgrade polyvinyl chloride. It is designed for use invertical and horizontal joints in concrete slabs andperipheral walls of structures and conduits conveying or containing liquid and of buried walls of pumpingstations. Masterflex PVC Waterstop is composed of two sections:
Moving and anchoring part
The surface of the anchoring parts of the MasterflexPVC Waterstop is furnished with ribs and naps. Thisprofile has two important functions to fulfil:
To increase the anchoring power of the waterstop in theconcrete
To lengthen the way of penetration around the cast-inwaterstop
Even under high stresses, the anchoring parts of theembedded waterstop will not be stretched and couldanchor to the concrete. This tight bonding will preventthe water to flow around the separated concrete andwaterstop. The movement part of the waterstop alonewill absorb the differences in width of the joint throughcontraction or constructural movements. MasterflexPVC Waterstop is resistant to attacks from ground andleakage water containing natural alkaline, acids andsalts They are also non-rotting and resistant to theeffects from short time exposure to oils and greases.When exposed permanently to oils and greases themost suitable raw materials should be specified.
Masterflex PVC Waterstop is made in accordance tothe corps. of Engineers Specification CRD C-570, C-572, C-573 and ASTM D-412, D-638, D-746, D-792, D-2240. It is also approved by WRc for suitable use withpotable water.
RECOMMENDED FOR
Water retaining
Reservoirs, water towers and sewage tanks
Dams, culverts, canals and spillways
Swimming pools
Bunded areas surrounding liquid retaining tanks
Water excluding
Basements and underground car parks
Tunnels and subways
Abutments and retaining walls
Roof decks and podium areas
FEATURES AND BENEFITS
Range of profiles
Fully continuous bulbed network
Simple on site jointing
TYPICAL PERFORMANCE DATATensile strength (<120 kgf/cm
2)
(CRD-C573): 165 kgf/cm
2
Elongation (<2501%)(CRD-C573)
: 380
Stiffness in flexure(CRD-571)
: 55 kg/cm2
Ozone resistance (ASTM D1149) : No cracks
Water absorption 50°C for 48 hoursIncrease in weight (ASTM D570)
: 0.37%
Effect of alkalies
Change in weight : +0.07
Change in hardness : +0.2
PROPERTIES
Specific gravity (<1.4) (ASTM D792) : 1.29
Shore A hardness(ASTM D2240)
: 80
Masterflex PVC Waterstop profiles
7/29/2019 Masterflex PVC Waterstop
http://slidepdf.com/reader/full/masterflex-pvc-waterstop 2/4
MASTERFLEXTM
PVC WATERSTOP
Dimension (mm)Type
W T D CB H
DD-4 102 5 13 - -
DD-6 152 5 13 - -
DD-8 203 5 13 - -
DD-9 230 5 13 - -
DD-10 255 5 13 - -
DD-12 305 5 13 - -
SDD-6 152 9.5 19 - -
SDD-8 203 9.5 19 - -
SDD-9 230 9.5 25 - -
SDD-12 305 9.5 25 - -
Dimension (mm)Type
W T D CB H
CD-4 102 5 13 20 10CD-6 152 5 13 18 8
CD-8 203 5 13 18 8
CD-9 230 5 17 21 11
CD-10 255 5 19 23 13
CD-12 305 6 19 25 13
SCD-6 152 5 19 30 15
SCD-8 203 9.5 19 30 15
SCD-9 230 9.5 25 38 19
Dimension (mm)Type
W T D CB H
CR-6 152 5 13 30 10
CR-8 203 5 13 30 20
CR-9 230 5 13 30 20
CR-12 305 5 13 30 20
SCR-10 250 10 17 - -
Dimension (mm)
Type W T D CB H
WP-6 150 3 15 - -
WP-8 200 3 18 - -
WP-10 250 3 18 - -
Dimension (mm)Type
W T D CB H
RT-7 195 3 15 - -
RR-8 203 5 13 - -
RR-9 230 5 13 - -
RR-10 250 5 13 - -
RR-12 305 5 13 - -
SRR-9 230 9.5 15 - -
7/29/2019 Masterflex PVC Waterstop
http://slidepdf.com/reader/full/masterflex-pvc-waterstop 3/4
MASTERFLEXTM
PVC WATERSTOP
APPLICATION
Selection of waterstopCentrally placed or surface mounted types can beapplied when the waterstop has the function of preventing water penetration from outside to inside(ground water, rain water, etc.)
For structures where water is intended to be retaininside for long periods such as swimming pools,sewerage plants, tunnels, channels etc., centrallyplaced types of waterstops should be fixed on the sidewhere the water pressure is existing or expected.Therefore, surface mounted waterstops are not advisedin the above mentioned situations as the risk of
mechanical damage for the unprotected surface type isconsiderably increased.
Steel shutters make it difficult to fix the waterstop ontothem; therefore centrally placed types are preferred insuch case.
Structures with tight and complicated reinforcementsmake it often impossible or it is too time consuming toinstall centrally placed waterstops; in such cases,surface mounted ones are preferred and advised.
Where high water pressure is to be expected, centrallyplaced types are preferred. This is because thepassage for the eventually penetrating water to runaround the waterstop is longer for the centrally placedones than for the surface mounted types, providing that
they have the same width as illustrated in the sketchesshown. Centre bulb types must be used for expansion joints and all other joints where the reinforcement barsdo not pass through the joint between the slabs.
Dumb-bell types are sufficient for construction jointswhere no differential movement is permitted and theplenar movement is only by concrete contraction.
Selection of size of waterstopExperience has proved that the application of a fewsimple rules will ensure a satisfactory choice:
The overall width of the waterstop should be equal or little less than the thickness of the concrete slab intowhich it is placed.
The width of the waterstop should be at least six timesthe size of the largest used aggregate.
The waterstop should be positioned in the centre of theslab.
Fixing and installationThe sealing functions of a waterstop however, can onlybe achieved properly, when all necessary measures are
taken into consideration for the installation. Besidestight weldings, it is essential to fasten the waterstopproperly to the reinforcement rods or to the formworkshutters, so that the profile cannot be moved out of position during placement of fresh concrete. Fullattention must be paid also while concrete is beingpoured so that no air pockets are created; the profilemust be embedded completely in the concrete,therefore it is important to prevent leaks along the faceof the shutters and the waterstop. To enable thewaterstop be wired securely to the reinforcement barsto other suitable points.
7/29/2019 Masterflex PVC Waterstop
http://slidepdf.com/reader/full/masterflex-pvc-waterstop 4/4
MASTERFLEXTM
PVC WATERSTOP
PRECAUTIONS
For Health, Safety and Environmental
Recommendations, please consult and follow all
instructions on the product Material Safety Data Sheet.
1-1-1-1006
STATEMENT OF
RESPONSIBILITY
The technical information and application advice given in this BASF Construction Chemicals publication arebased on the present state of our best scientific and practical knowledge. As the information herein is of ageneral nature, no assumption can be made as to a product's suitability for a particular use or application andno warranty as to its accuracy, reliability or completeness either expressed or implied is given other thanthose required by law. The user is responsible for checking the suitability of products for their intended use.
NOTEField service where provided does not constitute supervisory responsibility. Suggestions made by BASFConstruction Chemicals either orally or in writing may be followed, modified or rejected by the owner,engineer or contractor since they, and not BASF Construction Chemicals, are responsible for carrying outprocedures appropriate to a specific application.