6
SHADING SYSTEMS FOR LARGE AREAS safe · timeless · beautiful Stylish solar shading and weather protection for large areas Sleek and slender – the free-standing awning frame system for the markilux pergola 110 / 210 markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 rated to wind resistance class 3 (corresponds to Beaufort 6) www.samsonawnings.co.uk 01933 274276 11/2017 www.samsonawnings.co.uk 01933 274276 11/2017

markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

S H A D I N G S Y S T E M S F O R L A R G E A R E A S s af e · t im e le s s · b ea u t i f u l

Stylish solar shading and weather protection for large areasSleek and slender – the free-standing awning frame system for the markilux pergola 110 / 210

markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210

rated to wind resistance class 3

(corresponds to Beaufort 6)

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017

Page 2: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

markilux syncra 2 fix / uno fix pergola S H A D I N G S Y S T E M S F O R L A R G E A R E A S

366 | Special features w w w . m a r k i l u x . c o m

Design Features

sturdy, free-standing awning frame system in a more contemporary design

rounded support posts reflect the design style of the markilux folding-arm awnings

an elegant, free-standing awning support system resting on slender posts with unobtrusive lateral guide tracks

Technical Specification

free-standing awning frame system with two round support posts for the markilux pergola (in the case of the syncra 2 fix, two markilux pergolas, in the case of the syncra 2 uno fix, one markilux pergola)

especially large extensions provide generous shade with high wind stability (wind resistance class 3)

independent use of the individual awnings

simple fixture of the awning stand to a concrete foundation

For dimensions and technical details please consult the section on the pergola 110 / 210

Accessories

polyester powder coating in non-standard colours is available to individual order (prices on request, longer lead time)

the standard specification of the markilux pergola 110 / 210 is with hard-wired motor, optionally available with radio-controlled motor and markilux remote control

for individual awning model descriptions as well as optional accessories and bespoke options consult the section on the markilux pergola 110 / 210

For configuration options, colours and dimensions please consult the pergola 110 / 210 section of the sales manual.

with two markilux pergolas 110 / 210 with one markilux pergola 110 / 210markilux syncra 2 fix markilux syncra 2 uno fix

side view with markilux pergola 110 / 210

base plates for fixture to concrete footings

internal cavity for convenient storage and protection of any cabling

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017

Page 3: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

S H A D I N G S Y S T E M S F O R L A R G E A R E A S markilux syncra 2 fix / uno fix pergola

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

23

22

21

19

18

17

16

20A—A B—B

200

200

150

150

25

Ø 18 t = 12 4

00

340

30

Ø 20 t = 25

400 340

B B

SA SA

DH

VB

= 10

-111

Y

H

W

H

Ø 70

SH

2 1

2

AA

25

SH

1 A

H

Ø 140 Ø 70

GB = M

AH

S

H1

SAM1

25

SAM2 21 21

☐ 70* ☐ 70* ☐ 125*

w w w . m a r k i l u x . c o m Installation dimensions | 367

90

95

80

95

8585

F1

BG

armour matting basket made from rebar matting Q188(dimensions in cm)

armour matting basket made of 6 pieces of steel rebar, Ø 6 mm (dimensions in cm)

F1:

dimensions in mm

Installation dimensions

GBMSAM 1AHSH 1HSAM 2YSH 2

DHVBSA

WAXF1/F3BGt*

=========

===

======

headroomheight adjustment minimum 1 to maximum 11.1 cmseparation of the support posts of the markilux pergola to the support posts of the markilux syncraawning pitch 5° to 25°, factory set at 15°calculation value for SAconcrete foundationarmour matting basketthickness of the base plateInformation on angular posts

W

DHAH

H

SAM1

GB = M

F1

SASA

F1

F3

SH2

VB

SH1

SAM2

On site the following have to be prepared as per drawing for every post: → a concrete base of armoured concrete with a compressive strength of C25/30 (previously B25) with an armour matting basket made of rebar matting Q188 / rebar steel Ø 6 mm

→ the front base plates (F3) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021 (or equivalent)

→ the rear base plates (F1) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021 (or equivalent)

syncra 2 fix with markilux pergola 110 / 210 / single unit

F3:

80

60

70

50

BGF3

60

50

For dimensions, further technical details and configuration options please consult the pergola 110 / 210 section of the sales manual

overall width of the unit = awning width = order widthawning widthpost separation, centre to centre, of the markilux syncraunit heightmarkilux syncra post heightextensionpost separation, centre to centre, of the markilux pergolathe support post must be moved back a min. of 10 cm and a max. of 100 cmpost height of the markilux pergola

SA = cos W × (H − Y) + AX + 52,5 mm

DH = SH2 − sin W × Y

AH SH1 SAM 1 SAM 1* SH2 SAM 2 W AX

3470 3200 M − 140 M − 125 2500 SAM 1 + 42

5° 2610° 3215° 3820° 4425° 49

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017

Page 4: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

markilux syncra 2 fix / uno fix pergola S H A D I N G S Y S T E M S F O R L A R G E A R E A S

200

200

150

150

Ø 18

25

t = 12

SA SA

A–A

25

SH

1 A

H

12

A

DH

V

B =

10-1

11

A

SH

2

Ø 70 Ø 140 Ø 70

W

H

Y

H GB = M

25

B C

25

AH

S

H1

B C

400

3

40

Ø 20

400 340 3

0

B–B C–C

t = 25

SAM1

= =

400

3

40

400 340 3

0

t = 25 Ø 20

SAM2 21 21

368 | Installation dimensions w w w . m a r k i l u x . c o m

90

115

80

115

105105

F2

BG

armour matting basket made from rebar matting Q188(dimensions in cm)

F2:

dimensions in mm

Installation dimensions

GBMSAM 1AHSH 1HSAM 2YSH 2DH

VBSA

WAX12F1/F2/F3BGt*

==========

==

========

overall width of the unit = awning width = order widthawning widthpost separation, centre to centre, of the markilux syncraunit heightmarkilux syncra post heightextensionpost separation, centre to centre, of the markilux pergolathe support post must be moved back a min. of 10 cm and a max. of 100 cmpost height of the markilux pergolaheadroom

height adjustment minimum 1 to maximum 11.1 cmseparation of the support posts of the markilux pergola to the support posts of the markilux syncraawning pitch 5° to 25°, factory set at 15°calculation value for SAoutermost postcentral post (not required for widths up to 700 cm)concrete foundationarmour matting basketthickness of the base plateInformation on angular posts

W

DH

HGB = M

F1F2

F1

1 2 1AH

F3½ SAM1

½ SAM1

½ SAM2SASA

½ SAM2

F3F3

SH2

SH1

VB

On site the following have to be prepared as per drawing for every post: → a concrete base of armoured concrete with a compressive strength of C25/30 (previously B25) with an armour matting basket made of rebar matting Q188 /

rebar steel Ø 6 mm

→ the front base plates (F3) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021 (or equivalent)

→ the rear base plates (F1 and F2) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021

(or equivalent)

syncra 2 fix with markilux pergola 110 / 210 / coupled units

F1 and F3: see dimension overview of single unit

For dimensions, further technical details and configuration options please consult the pergola 110 / 210 section of the sales manual

SA = cos W × (H − Y) + AX + 52,5 mm

DH = SH2 − sin W × Y

AH SH1 SAM 1 SAM* SH2 SAM 2 W AX

3470 3200 M − 140 M − 125 2500SAM 1

+ 42

5° 2610° 3215° 3820° 4425° 49

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017

Page 5: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

S H A D I N G S Y S T E M S F O R L A R G E A R E A S markilux syncra 2 fix / uno fix pergola

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

23

22

21

19

18

17

16

20 200

200

150

150

Ø 18

25

t = 12

Y H

SH

1 A

H

SA 90

A–A

SH

2

DH

12 VB

= 10

-111

Ø 140 Ø 70

A A

W

AH

S

H1

B B

360

380

2

70

150

t = 25

150

90

B–B

Ø 20

30

25

80

GB = M

SAM1

25

SAM2 21 21

80

60

70

50

BGF3

60

50

w w w . m a r k i l u x . c o m Installation dimensions | 369

90

95

80

95

8585

F1

BG

armour matting basket made from rebar matting Q188(dimensions in cm)

armour matting basket made of 6 pieces of steel rebar, Ø 6 mm (dimensions in cm)

F1:

dimensions in mm

Installation dimensions

GBMSAM 1AHSH 1HSAM 2YSH 2

DHVBSA

WAXF1/F3BGt*

=========

===

======

W

AH

H

SAM2SA

GB = M

F1

F1

F3

F3VB

SH1

SAM1

DH

SH2

On site the following have to be prepared as per drawing for every post: → a concrete base of armoured concrete with a compressive strength of C25/30 (previously

B25) with an armour matting basket made of rebar matting Q188 / rebar steel Ø 6 mm

→ the front base plates (F3) are to be fixed using Fischer anchor bolts FAZ 10/30 in ma-

rine-grade stainless steel with washers certified to DIN 9021 (or equivalent)

→ the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts

FAZ II 16/50 and washers certified to DIN 9021 (or equivalent)

syncra 2 uno fix with the markilux pergola 110 / 210

F3:

For dimensions, further technical details and configuration options please consult the pergola 110 / 210 section of the sales manual

overall width of the unit = awning width = order widthawning widthpost separation, centre to centre, of the markilux syncraunit heightmarkilux syncra post heightextensionpost separation, centre to centre, of the markilux pergolathe support post must be moved back a min. of 10 cm and a max. of 100 cmpost height of the markilux pergola

headroomheight adjustment minimum 1 to maximum 11.1 cmseparation of the support posts of the markilux pergola to the support posts of the markilux syncraawning pitch 5° to 25°, factory set at 15°calculation value for SAconcrete foundationarmour matting basketthickness of the base plateInformation on angular posts

SA = cos W × (H − Y) + AX + 52,5 mm

DH = SH2 − sin W × Y

AH SH1 SAM 1 SAM 1* SH2 SAM 2 W AX

3470 3200 M − 140 M − 125 2500 SAM 1 + 42

5° 2610° 3215° 3820° 4425° 49

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017

Page 6: markilux syncra 2 fix / syncra 2 uno fix pergola 110 / 210 · 2017-11-27 · → the rear base plates (F1) to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ

markilux syncra 2 fix / uno fix pergola S H A D I N G S Y S T E M S F O R L A R G E A R E A S

150 200

150

2

00

Ø 18 t = 12

25

A–A

380

Ø 20 270

t = 25

360 300

80

B–B C–C

30

AH

S

H1

SH

1 AH

B B C C

GB = M

SAM 1 = = 90 SA

12

SH

2

A A

DH

V

B =

10-1

11

Y

H

W

Ø 70 Ø 140

380

Ø 20 270

t = 25

360 300

80

30

SAM2 21 21

370 | Installation dimensions

90

115

80

115

105105

F2

BG

F2:

dimensions in mm

Installation dimensions

W

AH

H

SA F3

GB = M

F1

1

12

F1

F2 F3

F3

VB

SH1

½ SAM2½ SAM2½ SAM1

½ SAM1

DH

SH2

On site the following have to be prepared as per drawing for every post: → a concrete base of armoured concrete with a compressive strength of C25/30 (previously B25) with an armour matting basket made of rebar matting Q188 /

rebar steel Ø 6 mm

→ the front base plates (F3) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021 (or equivalent)

→ the rear base plates (F1 and F2) are to be fixed using Fischer marine-grade stainless steel anchor bolts FAZ II 16/50 and washers certified to DIN 9021

(or equivalent)

syncra 2 uno fix with the markilux pergola 110 / 210 / coupled units

For dimensions, further technical details and configuration options please consult the pergola 110 / 210 section of the sales manual

armour matting basket made from rebar matting Q188(dimensions in cm)

F1 and F3: see dimension overview of single unit

GBMSAM 1AHSH 1HSAM 2YSH 2DH

VBSA

WAX12F1/F2/F3BGt*

==========

==

========

overall width of the unit = awning width = order widthawning widthpost separation, centre to centre, of the markilux syncraunit heightmarkilux syncra post heightextensionpost separation, centre to centre, of the markilux pergolathe support post must be moved back a min. of 10 cm and a max. of 100 cmpost height of the markilux pergolaheadroom

height adjustment minimum 1 to maximum 11.1 cmseparation of the support posts of the markilux pergola to the support posts of the markilux syncraawning pitch 5° to 25°, factory set at 15°calculation value for SAoutermost postcentral post (not required for widths up to 700 cm)concrete foundationarmour matting basketthickness of the base plateInformation on angular posts

SA = cos W × (H − Y) + AX + 52,5 mm

DH = SH2 − sin W × Y

AH SH1 SAM 1 SAM 1* SH2 SAM 2 W AX

3470 3200 M − 140 M − 125 2500SAM 1

+ 42

5° 2610° 3215° 3820° 4425° 49

www.samsonawnings.co.uk 01933 274276 11/2017

www.samsonawnings.co.uk 01933 274276 11/2017