Upload
dangkhuong
View
220
Download
0
Embed Size (px)
Citation preview
Marketing Division, Manufacturing Facility & Orders
9 C i r cu i t D r i veH e n d o n S A 5 0 1 4
A U S T R A L I A
Postal Address
PO Box 2346 Port Adelaide SA 5015
Telephone +618 8268 2033 • Facsimile +618 8347 0434
Email: [email protected]
D Y N E K P T Y L T DABN 16 007 758 465 • WHOLLY AUSTRALIAN OWNED COMPANY
Dynek Sutures manufactured to ISO 13485
T H E S Y M B O L O F T E C H N I C A L E X C E L L E N C E
D Y N E KS U T U R E S
G L O B A L
© Dynek Pty Ltd. BE053 28-05-2010
• Manufacture to ISO 13485Quality Standard
• AQIS approved laboratory
Dynek Pty Ltdthe company
Few professions are as demanding as modern medicine. From theskilled hands of the surgeon to the exacting duties of the operatingtheatre staff – surgery offers no room for compromise.This understanding of commitment to Quality is the driving force behindThe Southern Hemisphere’s leading supplier of surgical sutures; DynekPty Ltd.Dynek is proudly Australian owned. Its ‘state of the art’ manufacturingfacility is situated in Adelaide, the capital of South Australia.The company has been manufacturing quality sutures in South Australiasince 1974 and during this time has not remained inward looking;instead, a commitment to achieving the highest standards hasprevailed, ensuring dynamic growth and world class status as a supplierof the best surgical products.Dynek understands the unique needs of the medical profession andDynek’s fine surgical products exists as a result of close ongoingconsultation with medical professionals, and the knowledge gainedthrough meticulous research and development.Arising from this strong foundation, Dynek has established a reputationfor innovative product development and marketing, and today, suppliesin excess of 2000 different kinds of single use absorbable and non-absorbable sutures.Dynek is the only wholly Australian owned suture company.
DYNEK SUTURES
Plastic Micro Ophthalmic General O & G Cardiovascular Thoracic Paediatric Orthopaedic E.N.T. Neuro Orthodontic
At Dynek,Quality is placed above allother considerations.
No Compromisein pursuit of excellence
No compromise in Procedures,Equipment orSupplies.
Dynek suturesare made to uncompromisingstandards with provenperformance in many fields ofsurgery:
‘ s t a t e o f t h e a r t ’ l a b o r a t o r y . . .
A History of research, commitment and successful innovation
Dynek’s success has been widely acclaimed in Australia. Renownedfor its technical excellence, Dynek has produced a world class rangeof sutures, now exported around the globe.With production running into millions of sutures each year, Dyneklooked to the future when investing in a new ‘state of the art’manufacturing facility. This facility, along with advances in microengineering, has enhanced productivity and enabled the attainmentof ISO13485.In recent years, research and development has expanded into manynew areas. Dynek recognises that although research absorbs largeamounts of capital, the benefits to the medical profession and mostimportantly, the patient, are of paramount importance.Environmental concerns are foremost in people’s minds. Dynek iscommitted to ensuring that where possible, all products can berecycled or destroyed without harmful residue.A company’s greatest assets are the ideas and the visions of itsemployees.Dynek could not have achieved such advancements in technologywithout the proven performance of a well trained and dedicatedteam. The strength of this company is its people and their ongoingcommitment to quality and service.
Dynek described
Dynek is an equal opportunityemployer; driven by a one levelmanagement system with acommitment to staff trainingand further education.A responsible team ofprofessionals sensitive toenvironmental issues whilefocused on a common goal;the research and developmentof a world class product.
Dynek mission statement
We are committed to being theleading supplier of qualityworld class products in ourfield. Consistently providing alevel of quality andreliability of supply, that willequal or surpass theexpectations of our mostcritical customer.Proudly, our product is a resultof ongoing research anddevelopment, providing longterm benefits to the medicalprofession and mostimportantly the patient.
DYNEK SUTURES
Dynek privacy policy statement
Privacy Policy Objective - Toensure customers and DynekPty Ltd Personnel understandtheir rights and obligations withregard to preserving theprivacy of our customers.Privacy Statement - It is DynekPty Ltd intention to provide itscustomers with absoluteconfidence that all detailsrecorded by Dynek during thecourse of normal businessoperations are accorded theutmost confidentiality and thatthe full privacy of the customeris maintained at all times.
Needle specifications include:reverseconventionalFineline*straight cuttinground bodied taperLancet-SpatulaA-cute* taperreverse premium cutting point
Threads range from:plain catgutchromic catgutsilknylonpolyetherpolyesterpolyvinylidene fluoride(PVDF)polyglycolide
others available on request
The Dynek team is totally committed to the successful implementationand maintenance of Total Quality Control.Quality goals are achieved by the development and constant refining ofStandard Operating Procedures, thorough training, and continuouspersonnel education.Briefly, Dynek’s Quality Assurance Programme is executed by:
The employment of a team of Microbiologists to oversee Qualityprocedures.The validation of all incoming material to documented Qualitystandards.Ongoing Quality control checks made on all aspects of suturemanufacture.Strict testing procedures carried out to exacting Quality standards.The commitment of all personnel to support the company mandateto achieve, at all times, Quality in excess of that specified by worldstandards.
Dynek sutures are manufactured to Standard ISO 13485.Dynek is a company in which Total Quality Control is placed above allother considerations, a company whose primary task is absolutecustomer satisfaction and confidence in a product manufactured withpride under the Dynek trademark.
Qualitythe first word in our product
DYNEK SUTURES
DYNEK SUTURE MATERIALS AND TRADEMARKSAbsorbable Sutures
Non Absorbable Sutures
FINELINE* Needle
A-CUTE* TAPER Needle
Dermaloc* Skin Tone wound closure strips
Other non suture
IMPORTANT: Dynek sutures are single use only devices and should not be re-sterilised
The information contained in this catalogue is intended as a guide only.The final decision on suture selection and subsequent use remains the Surgeon’s.
CG No Trademark Chromic Catgut
PG No Trademark Plain Catgut
B BIOVEK* Violet Braided Coated Polyglycolide Synthetic Absorbable
B-C BIOVEK* UNDYED Beige Braided Coated Polyglycolide Synthetic Absorbable
V VILENE* Blue Monofilament Polyvinylidene Fluoride
N NYLENE* Blue Monofilament Nylon
D DYLOC* Blue Monofilament Polyether
S DYSILK* Black Braided Treated Silk
P-S DYFLEX* Green Braided Treated Polyester
P POLYFLEX* Black Braided Treated Polyester
T TEFLEX* White Braided Treated Polyester
R RADENE* Yellow Monofilament Polyvinylidene Fluoride
SS DYCROM* Monofilament Stainless Steel Wire
** TRADEMARK
DYNEK Research and Development leads to continuous improvement and replacement of products, andwe therefore reserve the right to make changes to specifications without notice.
CODE PRODUCT MATERIAL
CODE PRODUCT MATERIAL
CODE PRODUCT DESCRIPTION
DYNEK SUTURES
HOW TO INTERPRET DYNEK CODE NUMBERS
Code numbering is very important in the stock control and selection of sutures. There are manydifferent types, and this can make the choice difficult. We believe that codes must be kept simpleand should be easy to decipher.
The codes convey three pieces of information:A. The first letter(s) refer to the material.B. The next number(s) refer to the USP thread size.C. The final number(s) refer to the needle code.* If #1 precedes the thread size, this indicates a longer thread length than the standard.For example, N-306 has a 45cm thread, where N-1306 has a 76cm thread.
Pre-cut Lengths:Pre-cut lengths of sutures also have an easy to understand coding system. Please remember thatthe second letter of the code is equal to its numerical partner, i.e. A equals one strand; B equals twostrands; C equals three strands etc. The first number(s) indicate the USP thread size. The last twonumbers represent the thread length in inches eg: SM4024 = Silk x 13 strands size USP 4/0 x 24inches in length.Once the coding is understood it is possible to use the code without the catalogue. In a teachinghospital it is good practice for staff to be able to explain what they are using and how they selectedit.SYMBOL:The Symbol on the foil packet indicates the needle typeeg: = round bodied taper needle, = reverse cutting needleDOUBLE ARMED:Double armed sutures have two symbols ( ) next to the needle profile, to note two needles arein the foil packet.
Needle Type
Expiry Date
Lot No.
C: Needle Number in CatalogueA: Refers to the Suture Material
Length of Thread
Thread Size
Lift & Tear
DYNEK SUTURES
Single Use Only
Instructions For Use
Thread Type
B: Suture USP
PACKAGING INFORMATION
Packaging:
The packaging of sutures is very important toeveryone. Consequently, Dynek has developeda suture packet which is easy to use.
All Dynek sutures are colour coded using theinternationally accepted system, which allowseasy transition from one brand to another.
The Dynek primary foil packs are quick andeasy to open revealing the needle locked inplace to help prevent needle stick injury.
Expiry Dates:
To minimise stock holding, every Dynek primarypack and box label has the expiry date clearlyshown. This provides the Operating RoomStaff the ability to issue the sutures to otherareas.
Lot Numbers:
Every Dynek foil and label is clearly markedwith the lot number. Each lot number allows theproduct to be traced through every step ofproduction, ensuring maximum manufacturingcontrol and traceability.
DYNEK SUTURES
Specifications forAbsorbable Catgut Sutures
Specifications forNon-Absorbable Sutures
USP METRIC DIAMETER (MM) USP METRIC DIAMETER (MM)SIZE SIZE MINIMUM MAXIMUM SIZE SIZE MINIMUM MAXIMUM
8/0 0.5 0.050 0.069 10/0 0.2 0.020 0.0297/0 0.7 0.070 0.099 9/0 0.3 0.030 0.0396/0 1 0.100 0.149 8/0 0.4 0.040 0.0495/0 1.5 0.150 0.199 7/0 0.5 0.050 0.0694/0 2 0.200 0.249 6/0 0.7 0.070 0.0993/0 3 0.300 0.349 5/0 1 0.100 0.1492/0 3.5 0.350 0.399 4/0 1.5 0.150 0.1990 4 0.400 0.499 3/0 2 0.200 0.2491 5 0.500 0.599 2/0 3 0.300 0.3492 6 0.600 0.699 0 3.5 0.350 0.3993 7 0.700 0.799 1 4 0.400 0.4994 8 0.800 0.899 2 5 0.500 0.599
3 and 4 6 0.600 0.6995 7 0.700 0.7996 8 0.800 0.8997 9 0.900 0.999
Specifications forStainless Steel Sutures
Specifications forSynthetic Absorbable Sutures
USP METRIC DIAMETER (MM) USP METRIC DIAMETER (MM)SIZE SIZE MINIMUM MAXIMUM SIZE SIZE MINIMUM MAXIMUM
2/0 3 0.300 0.349 10/0 0.2 0.020 0.0290 3.5 0.350 0.399 9/0 0.3 0.030 0.0391 4 0.400 0.499 8/0 0.4 0.040 0.0492 5 0.500 0.599 7/0 0.5 0.050 0.069
3 and 4 6 0.600 0.699 6/0 0.7 0.070 0.0995 7 0.700 0.799 5/0 1 0.100 0.1496 8 0.800 0.899 4/0 1.5 0.150 0.1997 9 0.900 0.999 3/0 2 0.200 0.249
2/0 3 0.300 0.3490 3.5 0.350 0.3991 4 0.400 0.4992 5 0.500 0.599
3 and 4 6 0.600 0.6995 7 0.700 0.799
PACKAGING INFORMATION
Standards for Diameter:
DYNEK SUTURES
NEEDLE SPECIFICATIONS Types and Suggested Uses
REVERSE PREMIUM CUTTINGPOINT
REVERSE CUTTING
Flat shanked round-bodied needle constructed from a new seriesstainless steel, with an especially sharp cutting tip that allows foreasier penetration through hardened or calcified tissue. The needleis frequently used in cardiovascular and dental surgery.
A fine, flat-shanked round bodied taper needle with a speciallydesigned, sharp cutting point. This needle has been uniquelyconstructed for use in cardiovascular surgery to minimise the impactof the needle penetration on tissue trauma. The flat shanked bodyensures that the needle is held securely in the needle holder.
This flat shanked round bodied taper needle is ideal for soft, easilypenetrated tissues.
A range of bluntpoint needles are available for intestinal (liver)surgery.
A special hand-finished extremely sharp reverse cutting needledesigned for delicate tissue and ideal for plastic surgery.
A triangular reverse cutting needle, it is strong, retains it sharpnessand is considerably more resistant to bending than the standardconventional needle.
A flat-shanked plastic surgery needle designed for increased stabilityin the needle holder to permit accurate placement through the tissue.The conventional cutting point produces an excellent result incosmetic surgery.
A triangular cutting needle with the third cutting edge on its insideapex.
This square shanked, side cutting needle offers extra sharpness andpenetration, and is commonly used in ophthalmic surgery.
The majority of cutting needles are silicone treated to increasepenetration.
Dynek’s world leading CV300 needles for cardiovascular surgeryhave been developed to achieve extra penetration and a highbending resistance yet flexible when bent.
SILICONISED
CONVENTIONAL CUTTING
CV300
Important :As the range of needles iscontinually expanding, if theneedle you require is notlisted, please ask a Dyneksuture consultant.
ROUND BODIED TAPER
BLUNT POINT
FINELINE*
A-CUTE* TAPER
DYNEK SUTURES
LANCET - SPATULA
CARDIO CUTTING POINT
NEEDLE SELECTION
REVERSE PREMIUM CUTTING POINTNEEDLES1/2 Circle REVERSE PREMIUM CUTTINGPOINT
16 15MM
NEEDLE LENGTH (MM)
3/8 Circle REVERSE PREMIUM CUTTINGPOINT
3/8 Circle REVERSE CUTTING
NEEDLE LENGTH (MM)
2
40
4
5
6
47
7
9
31
13
10
12MM
13MM
16MM
18MM
24MM
26MM
28MM
30MM
35MM
40MM
45MM
15
14
34
90
16MM
18MM
25MM
60MM
REVERSE CUTTING NEEDLES1/2 Circle REVERSE CUTTING
DYNEK SUTURES
2D 11MM
24
20
3
21
8
16MM
18MM
20MM
24MM
26MM
13MM49
25
26
27
16MM
20MM
25MM
NEEDLE LENGTH (MM)
FINELINE* CUTTING NEEDLES3/8 Circle FINELINE* CUTTING
NEEDLE SELECTION
CONVENTIONAL CUTTING NEEDLES1/2 Circle CONVENTIONAL CUTTING
18
11
22MM
90MM
NEEDLE LENGTH (MM)
3/8 Circle CONVENTIONAL CUTTING
NEEDLE LENGTH (MM)
A-CUTE* TAPER NEEDLES1/2 Circle A-CUTE* TAPER
3/8 Circle A-CUTE* TAPER
ROUND BODIED TAPER NEEDLES1/2 Circle ROUND BODIED TAPER CV300
1/2 Circle ROUND BODIED TAPER HEAVY
NEEDLE LENGTH (MM)
18MM
20MM
25MM
35MM
45MM
55MM
35
58
32
42
44
83
51
55
60
64
65
68
69
70
85
10MM
13MM
16MM
18MM
20MM
25MM
30MM
35MM
65MM
86 76MM
97E5 40MM
70E5 35MM
98E5 48MM
63 18MM
DYNEK SUTURES
97 40MM
98 48MM
NEEDLE SELECTION
52
53
54
66
57
67
72
10MM
13MM
16MM
18MM
20MM
25MM
30MM
30
33
60MM
260MM
NEEDLE LENGTH (MM)
STRAIGHT CUTTING NEEDLES
3/8 Circle ROUND BODIED TAPER CV300NEEDLE LENGTH (MM)
Other Needles Available on Special Request
DYNEK SUTURES
3/8 Circle ROUND BODIED TAPER
3519 3.5MM
NEEDLE LENGTH (MM)
0.05MM
DIAM (MM)
351 3.5MM 0.07MM
MICRO NEEDLES
1/4 Circle LANCET SPATULA
1/2 Circle LANCET SPATULA
5.0MM 0.10MM502
LANCET-SPATULA NEEDLES3/8 Circle LANCET SPATULANEEDLE LENGTH (MM) DIAM (MM)
6010 6MM 0.15MM
6MM 0.20MM
6411 6.4MM 0.20MM
6011
6410 6.4MM 0.15MM
809 8.0MM 0.35MM
CARDIO POINT NEEDLES 3/8 Circle CARDIO POINT
NEEDLE LENGTH (MM) DIAM (MM)
8023 8.0MM 0.30MM
8022 8.0MM 0.25MM
13022 13.0MM 0.25MM
8520 8.5MM 0.30MM
643 6.4MM 0.15MM
644 6.4MM 0.20MM
5.0MM 0.15MM503
805 8.0MM 0.23MM
J TYPE ROUND BODIED TAPER CV300
1/4 Circle ROUND BODIED TAPER CV300
71 25MM
78 30MM
SURGICAL GUT CHROMIC & PLAIN
SURGICAL GUT
Dynek catgut is to our bestknowledge BSE FREE andproduced from bovine intestinalserosa. As an accredited AQISlaboratory, Dynek can onlyimport raw materials that are freefrom contamination.
Dynek CHROMIC gut ischromicised before it is spun intostrands. This allows control overthe amount of chromic contentfor an even absorption rate.
The specialised spinning andgrinding process creates a strandof uniform diameter. The suturestrand is then further polished toachieve maximum smoothness,for reliability and strength.
There are many sensible reasons forchoosing “DYNEK CATGUT”, but themost important can easily beoverlooked: the sheer pleasure ofworking with a Natural Fibre.
The selection of Plain andChromic Surgical Gut isdetermined by the rate ofhealing required in the tissuein which the suture is to be used.
4/0 3/0 2/0 0 1 2
DYNEK CATGUT
1
2
3
4
0
THREAD SIZE (USP)
5
6
OTHER STANDARD
DYNEK SUPER GUT – NATURALLY
NOTE: Tensile strength is determined as per the standard knot pull test stated in the United States Pharmacopoeia, Vol 23- NF18, for absorbable sutures utilising a surgeon’s knot.
TENSILE STRENGTH(KGF)
As this graph displays, when compared with other brands,Dynek Catgut is superior.
DYNEK SUTURES
CHROMIC SURGICAL GUT
LENGTH(cm) SUGGESTED USE
* A minimum order quantity may apply to this product
METRIC
THREAD SIZE
USP5/0 4/0 3/0 2/0
1.5 2 3 3.5
NEEDLE DESCRIPTION
REVERSE CUTTING2
12mm 3/8 Circle
40
13mm 3/8 Circle
4
16mm 3/8 Circle
5
18mm 3/8 Circle
6
24mm 3/8 Circle
47
26mm 3/8 Circle
9
30mm 3/8 Circle
15
16mm 1/2 Circle
34
35mm 1/2 Circle
Sub-Cuticular
Dental
Sub-Cuticular
Sub-Cuticular
Sub-Cuticular
Sub-Cuticular
Obstetrics &Gynaecology
Sub-Cuticular
50 CG502
50 CG5040
50 CG404 CG304
50 CG405 CG305
76 CG1405 CG1305
50 CG306 CG206
76 CG1306
50 CG2047*
50 CG209*
76 CG1209*
50 CG4015
76 CG12034
DentalOral Surgery
Dental/Sub-Cuticular/Oral Surgery
DYNEK SUTURES
CHROMIC SURGICAL GUT
LENGTH(cm) SUGGESTED USE
METRIC
THREAD SIZE
USP3/0 2/0 0 1
3 3.5 4 5
NEEDLE DESCRIPTION
17
45
12
35mm 1/2 Circle
40mm 1/2 Circle
48mm 1/2 Circle
76
100
76
50
CG3017* CG2017*
CG1117*
Obstetrics &Gynaecology
Obstetrics &GynaecologyCG1012* CG1112*
CG045*
REVERSE CUTTING
Obstetrics &Gynaecology
DYNEK SUTURES
* A minimum order quantity may apply to this productE5 Heavy Profile
CHROMIC SURGICAL GUT
LENGTH(cm) SUGGESTED USE
METRIC
THREAD SIZE
USP6/0 5/0 4/0 3/0 2/0 0 1 2
1 1.5 2 3 3.5 4 5 6
NEEDLE DESCRIPTION
REVERSE PREMIUM CUTTING POINT
24
16mm 3/8 Circle
20
18mm 3/8 Circle
50 CG6024 CG5024
50 CG4020*
2D
11mm 3/8 Circle
Plastic
Plastic
50 CG602D CG502D Plastic/ENT
STERILE LENGTHS - NON NEEDLE
DYNEK SUTURES
* A minimum order quantity may apply to this product
150 CGA3060 CGA2060 CGA060* CGA160* CGA260*Pre cutLengths
CHROMIC SURGICAL GUT
LENGTH(cm) SUGGESTED USE
METRIC
THREAD SIZE
USP5/0 4/0 3/0 2/0 0 1 2
1.5 2 3 3.5 4 5 6
NEEDLE DESCRIPTION
35mm 1/2 Circle + 35mm 1/2 Circle CUTTING
70+17Obstetrics &GynaecologyDCG2070E1*150
64
18mm 1/2 Circle
65
20mm 1/2 Circle
68
25mm 1/2 Circle
68+68
25mm 1/2 Circle
69
30mm 1/2 Circle
70
35mm 1/2 Circle
* A minimum order quantity may apply to this product
ROUND BODIED TAPER •
76 CG4064* CG3064*
76 CG4065* CG3065* CG2065*
76 CG5068* CG4068* CG3068 CG2068 CG068
76 DCG3068*
76 CG3069* CG2069* CG069 CG169
76 CG3070* CG2070* CG070 CG170
100 CG12070* CG1070* CG1170*
Urological
General/Intestinal
General/Intestinal
General/Intestinal
General/Intestinal
General/Intestinal
67
25mm 3/8 Circle
54
16mm 3/8 Circle
General/Intestinal
General/Intestinal
CG4054*
CG3067* CG2067*
76
76
DYNEK SUTURES
CHROMIC SURGICAL GUT
LENGTH(cm) SUGGESTED USE
* A minimum order quantity may apply to this product
42
35mm 1/2 Circle
Obstetrics &Gynaecology
General/Intestinal
ROUND BODIED TAPER (HEAVY)•
35mm 1/2 Circle
40mm 1/2 Circle
48mm 1/2 Circle
65mm 1/2 Circle
76mm 1/2 Circle
70E5
97E5
98E5
85
86
Obstetrics &Gynaecology
General/Intestinal
General/Intestinal
Obstetrics &Gynaecology
Obstetrics &Gynaecology
2/0
METRIC
THREAD SIZE
USPNEEDLE DESCRIPTION
0 1 2
3.5 4 5 6
CG170E5*
CG2097E5* CG097E5* CG197E5* CG297E5*
CG1097E5* CG1197E5* CG1297E5*
CG098E5* CG198E5* CG298E5*
CG1198E5*
CG1298E5*
CG2085*
CG2086* CG086*
CG2042*
76
76
100
76
100
76
76
76
A-CUTE* TAPER
E5 Heavy Profile
DYNEK SUTURES
ROUND BODIED TAPER •
90
2D
11mm 3/8 Circle
2
12mm 3/8 Circle
4
16mm 3/8 Circle
5
18mm 3/8 Circle
6
24mm 3/8 Circle
12
40mm 1/2 Circle
30
60mm STRAIGHT
PLAIN SURGICAL GUT
METRIC
THREAD SIZE
USP6/0 5/0 4/0 3/0 2/0 0 1
1 1.5 2 3 3.5 4 5
NEEDLE DESCRIPTION
LENGTH(cm) SUGGESTED USE
REVERSE CUTTING
Sub-Cuticular
Sub-Cuticular
Sub-Cuticular
Sub-Cuticular
General/Intestinal
Sub-Cuticular
50 PG602D PG502D Plastic/ENT
24
16mm 3/8 Circle
50 PG4024* Plastic
REVERSE PREMIUM CUTTING POINT
* A minimum order quantity may apply to this product
A-CUTE* TAPER
32
25mm 1/2 Circle
50 PG3032Z General/Dental
General/Intestinal
50 PG502
50 PG504 PG404 PG304
76 PG1404
50 PG405 PG305
76 PG1405* PG1305
50 PG306 PG206
76 PG1206
76 PG1112*
100 PG3030* PG2030*
DYNEK SUTURES
PLAIN SURGICAL GUT
LENGTH(cm) SUGGESTED USE
STERILE LENGTHS - NON NEEDLE
* A minimum order quantity may apply to this product
METRIC
THREAD SIZE
USP4/0 3/0 2/0 0 1 2
2 3 3.5 4 5 6
NEEDLE DESCRIPTION
ROUND BODIED TAPER •
150 PGA4060* PGA3060 PGA2060 PGA060* PGA160* PGA260*Pre cutLengths
65
20mm 1/2 Circle
68
25mm 1/2 Circle
69
30mm 1/2 Circle
70
35mm 1/2 Circle
97E5
40mm 1/2 Circle
98E5
48mm 1/2 Circle
86
76mm 1/2 Circle
General /Intestinal
General /Intestinal
General /Intestinal
General /Intestinal
General /Intestinal
General /Intestinal
General /Intestinal
76 PG4065 PG3065 PG2065*
76 PG3068 PG2068 PG068*
76 PG3069* PG2069* PG069* PG169*
76 PG2070 PG070* PG170*
100 PG1070*
76 PG2097 PG097*
76 PG2098E5* PG198E5*
100 PG1198E5* PG1298E5*
76 PG2086* PG086*
PG2097E5 PG097E5*76
76 PG4054*
54
16mm 3/8 Circle
DYNEK SUTURES