2
MARKET LEADERS IN FILTRATION RONA LENTICULAR HSG REV:1 OCT 2013 AUSTRALIA & NEW ZEALAND FEATURES • Compact design • Ease of handling • Designed to house 1, 2, 3 or 4 modules -12” and 16” diameter with flat gasket or double o-ring bayonet adapter. All internal parts in contact with the liquid to be filtered are mechanically polished to a high degree (roughness<- Ra 0.8um) enabling ease of washing and sterilization during cleaning Operations and also to comply with health and sanitation standards. • The bell housing locking system is secured by bolt clamps, which also allow quick release. This type of clamp arrangement eliminates risk of injury or damage due to unvented housing pressure. • The ball valve and sampling valve act as a steam trap and condensation drain during sterilization procedures. • The top of the housing bowl is designed to fit a vent valve plus pressure gauge, if required. Vent valve with hose adaptor can be utilized to purge the housing at completion of filter run. This prevents any cross contamination with flushing agents APPLICATIONS • Purification of wine & beer • Element subtraction in fruit juice • Element subtraction in tea-based beverages • Prefiltration of juice concentrate • Polishing filtration of olive oil • Lenticular filter housing units have a long history in Food and Beverage applications for small batch production or medium flow rate applications. OPERATING CONDITIONS 12” and 16” housings, basic and advanced models Max operating pressure at 20ºC 8 bar Max operating pressure at 95ºC 6 bar Max operating temperature with EP seal 120ºC Max operating temperature with silicone seal 145ºC MATERIALS OF CONSTRUCTION On top of the housing cover is a venting assembly Options: • Stainless steel 100mm, glycerine filled pressure gauge, 0-6 bar or 0-10ba • Sight glass • Vent ball valve with hose adaptor, 12 mm diameter • Gas inlet valve with 1/4” BS threaded female fitting Housing material: AISI 316L Type of seal: EP (standard) Polishing Standard mechanical, electro polish on request. Internal Finishing: Mechanical Polishing Internal Roughness: Ra<0.8 Micron External Finishing: Mechanical Polishing Housing DEPTH FILTER Progressive Group’s Lenticular Filter Housings are available in 12” & 16” diameter to suit a wide range of applications typically used as a prefilter to final membrane filtering. The lowest part of the inlet bend is equipped with a 1/2” BS threaded male fitting, where a drain valve can be fitted. The housing cover has a 1/2” BSP-M fitting for sight glass pressure gauge and vent valve assemblies.

MARET LEADERS IN FILTRATION - Progressive Group€¦ · • Compact design • Ease of handling • Designed to house 1, 2, 3 or 4 modules -12” and 16” diameter with flat gasket

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MARET LEADERS IN FILTRATION - Progressive Group€¦ · • Compact design • Ease of handling • Designed to house 1, 2, 3 or 4 modules -12” and 16” diameter with flat gasket

MARKET LEADERS IN FILTRATION

RONA LENTICULAR HSG REV:1 OCT 2013

AUSTRALIA & NEW ZEALAND

FEATURES•Compactdesign•Easeofhandling•Designedtohouse1,2,3or4modules-12”and16”diameterwithflatgasketordoubleo-ringbayonetadapter.Allinternalpartsincontactwiththeliquidtobefilteredaremechanicallypolishedtoahighdegree(roughness<-Ra0.8um)enablingeaseofwashingandsterilizationduringcleaningOperationsandalsotocomplywithhealthandsanitationstandards.

•Thebellhousinglockingsystemissecuredbyboltclamps,whichalsoallowquickrelease.Thistypeofclamparrangementeliminatesriskofinjuryordamageduetounventedhousingpressure.

•Theballvalveandsamplingvalveactasasteamtrapandcondensationdrainduringsterilizationprocedures.

•Thetopofthehousingbowlisdesignedtofitaventvalvepluspressuregauge,ifrequired.Ventvalvewithhoseadaptorcanbeutilizedtopurgethehousingatcompletionoffilterrun.Thispreventsanycrosscontaminationwithflushingagents

APPLICATIONS•Purificationofwine&beer•Elementsubtractioninfruitjuice•Elementsubtractionintea-basedbeverages•Prefiltrationofjuiceconcentrate•Polishingfiltrationofoliveoil•LenticularfilterhousingunitshavealonghistoryinFoodandBeverageapplicationsforsmallbatchproductionormediumflowrateapplications.

OPERATING CONDITIONS 12”and16”housings,basicandadvancedmodelsMaxoperatingpressureat20ºC8barMaxoperatingpressureat95ºC6barMaxoperatingtemperaturewithEPseal120ºCMaxoperatingtemperaturewithsiliconeseal145ºC

MATERIALS OF CONSTRUCTIONOntopofthehousingcoverisaventingassemblyOptions:

•Stainlesssteel100mm,glycerinefilledpressuregauge,0-6baror0-10ba

•Sightglass•Ventballvalvewithhoseadaptor,12mmdiameter

•Gasinletvalvewith1/4”BSthreadedfemalefitting

Housing material: AISI316LType of seal: EP(standard)PolishingStandardmechanical,electropolishonrequest.Internal Finishing: MechanicalPolishingInternal Roughness: Ra<0.8MicronExternal Finishing: MechanicalPolishing

HousingDEPTH FILTER

Progressive Group’s Lenticular Filter Housings are available in 12” & 16” diameter to suit a wide range of applications typically used as a prefilter to final membrane filtering. The lowest part of the inlet bend is equipped with a 1/2” BS threaded male fitting, where a drain valve can be fitted. The housing cover has a 1/2” BSP-M fitting for sight glass pressure gauge and vent valve assemblies.

Page 2: MARET LEADERS IN FILTRATION - Progressive Group€¦ · • Compact design • Ease of handling • Designed to house 1, 2, 3 or 4 modules -12” and 16” diameter with flat gasket

Australia Office:P: +61 (0) 3 9872 6811 F: +61 (0) 3 9872 6822 E: [email protected] 17 Redland Drive, Mitcham, 3132, Victoria, Australiawww.progressivegroup.com.au

New Zealand Office:P: +64 (0) 9 951 3142F: +64 (0) 9 951 3143E: [email protected] Farnham Street, Parnell, Auckland, 1052, New Zealandwww.progressivegroupnz.co.nz

ORDERING INFORMATION

ADJUSTABLE LEGS ±20

DN DN

601310010601300010

+ SIGHT GLASS1 SANITARY VALVE2 SANITARY VALVES

SAMPLING TESTBALL VALVEBUTTERFLY VALVE

602310150602300150602320150

6017000101 BALL VALVE

DN DN

FLAT GASKETADJUSTABLE LEGS ±20

601310010601300010

+ SIGHT GLASS1 SANITARY VALVE2 SANITARY VALVES

SAMPLING TESTBALL VALVEBUTTERFLY VALVE

602310150602300150602320150

MEASUREMENTS

OPTIONAL ACCESSORIES

RANGE END FITTINGMODULE

SIZE (inch)

MODULES DN

505 0: FlatGasketNoDrains 12 1 1038 (Weld1.5”)

3038 (Clamp1.5”) 2040 (RJTMALEPART1.5”)

2: FlatGasket2Drains 16 2 1051 (Weld2.0”)

3051 (Clamp2.0”) 2050 (RJTMALEPART2.0”)

3: BayonetNoDrains 3

4: Bayonet2Drains 4