6
Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors’ Association (www.area-eur.be) Training and Certification schemes to ensure the safe and environmentally friendly handling of Low GWP alternative refrigerants Bangkok, 21st April 2015

Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors’ Association () Training and Certification schemes

Embed Size (px)

Citation preview

Marco BuoniVicePresident, AREA

Air Conditioning & Refrigeration European contractors’ Association(www.area-eur.be)

Training and Certification schemes to ensure the safe and environmentally friendly handling of

Low GWP alternative refrigerants

Bangkok, 21st April 2015

Contractors’ training with low GWP refrigerants: mind the gap!

In EUROPE,the use of HFCs is legislatively decreased ( by 79% by 2030 ) and consequently the use of alternative refrigerants is pushed, there will probably be a gap between training offer and training needs resulting in a shortage of trained contractors

(2012)

Why creatingTraining, Assessment, Certification

Training and Certification is an important tool and the only way to reach the competence necessary to handle refrigerants and the systems Legislation-driven:•Environment

1. Reducing Refrigerant Emissions, GHG, ODS2. Increasing energy efficiency (reducing CO2)

•Safety

Customer-driven:•Wholesalers, distributors, big customers … require environmentally friendly and energy efficient products•Protects the interests of customer through providing services according to applicable standards

Certification of the personnel and of the companies who handle air conditioning, refrigeration and heat pumps equipment should be necessary

To buy refrigerantTo install, repair, dismantling

Recommendations of AREA: Minimum Requirements for the specific refrigerant HC – NH3– CO2– HFO

COMPETENCE OF SERVICE TECHNICIANS Assessment: P Practical T Thoretical HC NH3 CO2 HFO

BASIC THERMODYNAMICS AND PHYSICS T T T T

• Properties : temperature, pressure, density, thermal capacity..• Differences between Low GWP refrigerants and HFCs• ……

GOOD PRACTICE P P P P

• Identify typical application• State and identify the commonly used refrigerants designation• ……

HEALTH AND SAFETY REQUIREMENTS P P P P

• Safe system shutdown and isolation• Extinguish a fire, First aid care treatment• ……

REGULATIONS AND STANDARDS T T T T

• Knowledge of International and National Regulations standards • Storage of the refrigerant• …….

Details in AREA Guidance

www.area-eur.be

FREE Blended learning for alternative refrigerants in new equipment

safety, efficiency, reliability and containment

e-learning

classroom practice

e-library

Co-financed by

We are proud to have among our

stakeholders the European Commission DG Clima & UNEP Ozone Action

REAL Alternativeswww.realalternatives.eu

THANK YOU!

Email: [email protected]

Marco BuoniVicePresident, AREA

Air Conditioning & Refrigeration European contractors’ Association(www.area-eur.be)

Secretary General Italian Association of Refrigeration Technician, ATF (www.associazioneATF.org)