MANUAL AND AUTOMATIC RESUSCITATION SYSTEM
MARS IIMARS II is a leading resuscitator developed for healthcare professionals and fi rst responders. MARS II is specifi cally designed to help emergency personnel, respond to patients that require resuscitation. The device can be used in confi ned spaces, low oxygen/toxic environments.MARS II meets the requirments of ISO 10651-5:2006 and European Resuscitation Council Guidelines for Resuscitation 2010 for ventilatory resuscitators.The MARS II is available in all regional gas-standards.MARS II can be used for children (20 kg), small adults and adults.
FEATURES• Simple to use• Robust design to withstand harsh environments• Can be enabled for automatic or manual (CPR)
resuscitation
TECHNICAL DATA - MARS II CONTROL MODULEGas: O2
Material: Brass, aluminium main inside parts, abs cover
Dimensions: 165× 110×63 mm
Weight: 1300 g
Regulator inlet connections: According regional high pressure standards
Inlet pressure (without reg.): 3.6 - 6 bar @ 100lpm
Working pressure: 3 bar
Inlet connection (module): Regional standard low pressure probe
Regulator performance: min 100 lpm and min 3 bar
Inlet filter: 30µm
Time to revert to automatic resuscitation: 5 - 7 seconds
Gas consumption: 9.6 lpm (Adult mode)
Connections according to European and International standards.
STANDARD RESUS MODE (AUTOMATIC)Setting Frequency
(min-1)Delivered volu-me (ml) I:E ratio Period
(s)On time(s)
O� time (s)
Adult: 70-100 kg 10 960 1:2 6 2.00 4.00
Small Adult: 40-70 kg 12 670 1:2 5 1.67 3.33
Child: 20-40 kg 20 240 1:2 3 1.00 2.00
ADULT RESUS MODE - ADULT ONLY (AUTOMATIC)Setting Frequency
(min-1)Delivered volu-me (ml) I:E ratio Period
(s)On time(s)
O� time (s)
Adult: 70-100 kg 10 960 1:2 6 2.00 4.00
MANUAL VENTILATIONSetting Flow (l/min)
Adult: 70-100 kg 36
Small Adult: 40-70 kg 28
Child: 20-40 kg 12
MARS II DEMAND VALVEMaterial: Polycarbonate, silicone, rubber, stainless steel
Dimensions: 120 × 50 × 70 mm
Weight: 175 g
Inspiratory resistance @ 5 lpm: -2.3 hPa (-2.3 cm H2O)
Inspiratory resistance @ 60 lpm: -4.4 hPa (-4.4 cm H2O)
Expiratory resistance @ 60 lpm: +4.8 hPa (+4.8 cm H2O)
Demand valve flow Spontaneous breathing: 0 -100 lpm
Relieve valve triggering pressure: 55 hPa (55 cm H2O)
Alarm valve triggering pressure: 46 hPa (46 cm H2O)
Connections according to European and International standards.
MARS II HOSE ASSEMBLYConnection Probes: By the national standards
Working pressure: 4.2 bar
Burst pressure: ±56 bar / 23°C and ±40 bar / 40°C
Material: PVC, anti-static in accordance with ISO 5359
Lenght: 1.2 m
Diameter: from 14 mm
Connections according to European and International standards.
Control module
Demand valve
The GCE Medical, MARS II is a manual (CPR) and automatic resuscitator and based around three central components : Control Module – Demand Valve – Regulator or integrated valve. Depending on the needs and national standards the MARS II can be delivered in many variants. In combinations the following features will be delivered.
AUTOMATIC VOLUME CYCLED RESUSCITATIONThe gas supply passes through the automatic channel and is delivered to the patient as a specific inhalation/exhalation breathing programme in accordance with the body weight, as set on the flow selector.
AUTOMATIC SWITCH TO BREATHING ON DEMANDWhen consciousness is regained, the patient will draw gas through the patient valve from the demand supply side of the module. The sensing of this flow instantly shuts down the automatic breathing programme.
AUTO-RETURN TO AUTOMATIC RESUSCITATIONShould spontaneous breathing lapse the module will sense the lack of flow; and volume cycled resuscitation will resume within 5-7 seconds.
AUDIBLE ALARMSet at 46 cm H20 pressure and mounted in the patient valve, an audible warning of airway blockage or over-pressurization of the patient is given to the operator.
OVERRIDE TRIGGERMounted in the patient valve, the override trigger enables the operator to perform initial lung saturation and manual resuscitation. On operation of the trigger, the automatic cycle will shut down but restart if the trigger is not re-operated within 5-7 seconds. Total manual operation for use in conjunction with cardiopulmonary massage can be undertaken by selecting the ‘MAN’ position on the flow selector.
MARS II REGULATORPressure gauge (reg): 0-200 bar
Therapy flows (reg): 1 to 25 lpm
Therapy outlet: Universal firtree 6 mm
Outlet pressure: 4.2 bar
Pressure relief valve setting: 8.4 bar
Quick connector: Regional standard according probe
Connections according to European and International standards.Standard: ISO 10524-1
Operating temperature: -18°C to +50°C
Storage temperature: -40°C to +60°C
Manufacturer: GCE, s.r.o, Žižkova 381, 583 81 Chotěboř, CZ
CE-marking: CE2460
MARS II ACCESSORIESCover hose assembly
Bacterial patient filter
Masks
Connections according to European and International standards.
Cover hose assembly
visit: www.gcegroup.com
REGIONAL OFFICES
EUROPE
CZECH REPUBLICFRANCEGERMANYHUNGARYITALYPOLANDPORTUGALROMANIASPAINSWEDENUNITED KINGDOM & IRELAND
AMERICA
LATIN AMERICAMEXICOUSA
ASIA
CHINAINDIARUSSIA
UNITED STATESOF AMERICA
CHINA
INDIA
RUSSIA
MEXICO
SWEDEN
POLANDGERMANY
FRANCE
SPAIN ITALY
IRELAND
UNITEDKINGDOM
PORTUGAL
ROMANIA
CZECH REPUBLIC
HUNGARY
PANAMA
GCE Groupwww.gcegroup.com
Art. Nr. 735100000588. Edition 1/2018. Alterations are subject to change without notice. 10012018ea© 2018