Majestic Outdoor Fireplace Manual

Embed Size (px)

Citation preview

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    1/20

    Outdoor Gas Fireplace

    Models: ODGSR36A, ODGSR42A

    PLEASE READ THIS MANUAL

    BEFORE INSTALLING AND USING

    APPLIANCE.

    WARNING: If the information in this

    manual is not followed exactly, a fire or

    explosion may result causing property

    damage, personal injury or loss of life.

    Do not store or use gasoline or otherflammable vapors and liquids in the

    vicinity of this or any other appliance

    WHAT TO DO IF YOU SMELL GAS

    Do not try to light any appliance.

    Do not touch any electrical switch;do not use any phone in your

    building.

    Immediately call your gas supplierfrom a neighbor's phone. Follow

    the gas supplier's instructions.

    If you cannot reach your gassupplier, call the fire department.

    Installation and service must beperformed by a qualified installer,

    service agency or the gas supplier.

    WARNING: Improperinstallation,

    adjustment,alteration,serviceor

    maintenancecancauseinjuryor

    propertydamage.Readtheinstallation,

    operatingandmaintenanceinstructions

    thoroughlybeforeinstallingorservicing

    thisequipment.

    WARNING:

    For Outdoor Use ONLY.

    INSTALLER/CONSUMER

    SAFETY INFORMATION

    Homeowner'sInstallationandOperatingManual

    DESIGN

    CERTIFIED

    200071145/09Rev.14

    CERTIFIED

    INSTALLER: Leave this manual with the appliance.

    CONSUMER: Retain this manual for future reference.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    2/20

    2

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Table of ContentsThank you and Congratulations on your purchase of a MHSC fireplace.

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE

    IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these

    instructions may result in a possible fire hazard and will void the warranty.

    Installation & Operating Instructions..........................................................................................3

    GeneralInformation............................................................................................................. 3 FireplaceDimensions..........................................................................................................4

    MoistureResistance............................................................................................................5

    ScreenedPorchInstallation................................................................................................5

    ClearancetoCombustibles.................................................................................................5

    Mantels...............................................................................................................................5

    Hearth ...............................................................................................................................5

    MoistureResistance............................................................................................................6

    Framing&Finishing............................................................................................................6

    FinalFinishing..................................................................................................................... 6

    GasSpecifications...............................................................................................................7

    GasInlet&ManifoldPressures...........................................................................................7

    HighElevations...................................................................................................................7

    ValveAccess.......................................................................................................................7 ExteriorChaseInstallation..................................................................................................8

    GasLineInstallation............................................................................................................8

    RemoteWallSwitch............................................................................................................9

    Operating Instructions

    LogInstallation..................................................................................................................10

    LavaRock......................................................................................................................... 10

    FirstFiring......................................................................................................................... 10

    FlameAdjustment.............................................................................................................. 11

    FlameCharacteristics........................................................................................................ 11

    OptionalWeatherEnclosures............................................................................................12

    OptionalStainlessSteelHood...........................................................................................12

    Lighting&OperatingInstructions......................................................................................13 Troubleshooting................................................................................................................. 14

    Maintenance................................................................................................................................. 15

    Replacement Parts......................................................................................................................16

    Accessories..................................................................................................................................18

    Warranty.......................................................................................................................................19

    Proposition 65 Warning:Fuelsusedingas,wood-

    burningoroilfiredappliances,andtheproductsof

    combustionofsuchfuels,containchemicalsknownto

    theStateofCaliforniatocausecancer,birthdefects

    andotherreproductiveharm.

    CaliforniaHealth&SafetyCodeSec.25249.6

    IMPORTANT:

    PLEASE READ THE FOLLOWING CAREFULLY

    Removeanyplasticfromtrimpartsbeforeturningthe

    fireplaceON.

    Itisnormalforfireplacesfabricatedofsteeltogiveoffsomeexpansionand/orcontractionnoisesduringthe

    startuporcooldowncycle.Similarnoisesarefound

    withyourfurnaceheatexchangerorcarengine.

    ItisnotunusualforyourMajesticFireplacesgasfire-

    placetogiveoffsomeodorthefirsttimeitisburned.

    Thisisduetothecuringofthepaintandanyunde-

    tectedoilusedinthemanufacturingprocess.

    Itisrecommendedthatyouburnyourfireplaceforat

    leastten(10)continuoushoursthefirsttimeyouuseit.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    3/20

    3

    ODGSR Series Outdoor Gas Fireplace

    20007114

    General InformationThisgasapplianceshouldbeinstalledbyaqualified

    installerinaccordancewithlocalbuildingcodesandwith

    currentCSA-B149.1InstallationcodesforGasBurning

    AppliancesandEquipment.

    FORU.S.AInstallationsfollowlocalcodesand/orthecur-

    rentNational Fuel Gas Code. ANSI Z223.1/NFPA 54.

    IntheCommonwealthofMassachusetts,allgasfittings

    andinstallationofthisheatershallonlybedonebya

    licensedgasfitterorlicensedplumber.

    FOR SAFE INSTALLATION AND OPERATION PLEASE

    NOTE THE FOLLOWING:

    1. Thisappliancegivesoffhightemperaturesandshouldbe

    locatedoutofhightrafficareasandawayfromfurniture.

    2. Childrenandadultsshouldbealertedtothehazardsofthe

    highsurfacetemperaturesofthisapplianceandshouldstay

    awaytoavoidburnsorignitionofclothing.

    3. Childrenshouldbecarefullysupervisedwhentheyareinthe

    sameroomasyourappliance.

    4. Undernocircumstancesshouldthisappliancebemodified.Partshavingtoberemovedforservicingshouldbereplaced

    priortooperatingthisapplianceagain.

    5. Installationandanyrepairstothisapplianceshouldbecar-

    riedoutbyaqualifiedserviceperson.Aprofessionalservice

    personshouldbecontactedtoinspectthisappliancean-

    nually.Makeitapracticetohaveallofyourgasappliances

    checkedannually.Morefrequentcleaningmayberequired

    duetoexcesslintanddustfromcarpeting,beddingmaterial,

    etc.

    6. Controlcompartments,burnersandairpassagesinthisap-

    plianceshouldbekeptcleanandfreeofdustandlint.Make

    surethatthegasvalveandpilotlightareturnedoffbefore

    youattempttocleanthisunit.

    7. Keeptheareaaroundyourapplianceclearofcombustible

    materials,gasolineandotherflammablevaporandliquids.

    Thisapplianceshouldnotbeusedasadryingrackforcloth-

    ing,norshouldChristmasstockingsordecorationsbehung

    intheareaofit.

    8. Undernocircumstancesshouldanysolidfuels(wood,coal,

    paperorcardboardetc.)beusedinthisappliance.

    9. Theflowofcombustionandventilationairmustnotbeob-

    structedinanyway.

    10.Whethertheapplianceisinstalleddirectlyoncarpeting,vinyl

    tileoranycombustiblematerialotherthanwood,thisappli-

    ancemustbeinstalledonametalorwoodpanelextending

    thefullwidthanddepthoftheappliance.

    11.Thisappliancerequiresadequateventilationandcombus-

    tionairtooperateproperly.

    12.Donotusethisapplianceifanyparthasbeenunderwater.Immediatelycallaqualifiedservicetechniciantoinspectthe

    applianceandtoreplaceanypartofthecontrolsystemor

    gascontrolthathasbeenunderwater.

    13.Inspecttheburnerbeforeeachuseoftheappliance.The

    burnermustbereplacedpriortooperationifthereisevi-

    dencetheburnerisdamaged.Useonlyburnerspecifiedby

    manufacturer.

    LP-cylinderenclosures,ifprovidedbytheconsumermustcon-

    formtothedesignparametersasdetailedbelow.

    Enclosures for LP-Gas Supply Systems

    EnclosuresforLP-gassupplycylindersshallbeventilatedby

    openingsatthelevelofthecylindervalveandatfloorlevel.The

    effectivenessoftheopening(s)forpurposesofventilationshall

    bedeterminedwiththeLP-gassupplycylinder(s)inplace.This

    shallbeaccomplishedbyoneofthefollowing:a. Onesideoftheenclosureshallbecompletelyopen;or

    b. Foranenclosurehavingfoursides,atopandabottom:

    1. Atleasttwoventilationopeningsatcylindervalvelevel

    shallbeprovidedinthesidewall,equallysized,spacedat

    180degrees(3.14rad),andunobstructed.Eachopening

    shallhaveatotalfreeareaofnotlessthan1/2square

    inchperpound(3.2sq.cm/kg)ofstoredfuelcapacityand

    notlessthanatotalfreeareaof10squareinches(64.5

    sq.cm).

    2. Ventilationopening(s)shallbeprovidedatfloorleveland

    shallhaveatotalfreeareaofnotlessthan1/2square

    inchperpound(3.2sq.cm/kg)ofstoredfuelcapacityand

    notlessthanatotalfreeareaof10squareinches(64.5

    sq.cm).Ifventilationopeningsatfloorlevelareinasideall,thereshallbeatleasttwoopenings.Thebottomof

    theopeningsshallbeatfloorlevelandtheupperedgeno

    morethan5inches(127mm)abovethefloor.Theopen-

    ingsshallbeequallysized,spacedat180degrees(3.14

    rad)andunobstructed.

    3. Everyopeningshallhaveminimumdimensionssoasto

    permittheentranceofa1/8inch(3.2mm)diameterrod.

    Cylindervalvesshallbereadilyaccessibleforhandoperation.

    Adoorontheenclosuretogainaccesstothecylindervalves

    isacceptable,provideditisnon-lockingandcanbeopened

    withouttheuseoftools.

    Thereshallbeaminimumclearanceof2inches(51mm)

    betweenthelowersurfaceoftheflooroftheLP-gassupply

    cylinderenclosureandtheground.Thedesignoftheapplianceshallbesuchthat(1)theLP-gas

    supplycylinder(s)canbeconnected,disconnectedandthe

    connectionsinspectedandtestedoutsidethecylinderenclo-

    sure;and(2)thoseconnectionswhichcouldbedisturbedwhen

    installingthecylinder(s)intheenclosurecanbeleaktested

    insidetheenclosure.

    Description

    TheODGSRSeriesareradiantfireplaces.Donotburnwood

    orothermaterialsintheseappliances.Eachmodelisavailable

    withstandingpilotforusewithNaturalorPropanegasunits.

    Reporttoyourdealeranypartsdamagedinshipment.

    Adequatecombustionandventilationairmustbeprovided.TheflowofcombustionandventilationairMUSTNOTbeobstruct-

    ed.

    Provideadequateclearancesaroundtheairopeningintothe

    combustionchamber;andadequateaccessibilityclearancefor

    servicingandproperoperation.NEVERobstructthefrontopen-

    ingoftheappliance.

    This fireplace is not designed to be water tight.

    Therefore, when installing this unit against an exte-

    rior wall, the wall must be finished before setting unit

    in place.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    4/20

    4

    ODGSR Series Outdoor Gas Fireplace

    20007114

    42"(1067mm)

    46"(1168mm)

    396"(1007mm)

    6"(

    16mm)

    50" (1270mm)

    50"(1270mm)

    56O" (13mm)

    56O"

    56O"(

    1791

    mm)

    "

    (610mm)

    436M"(1111mm)

    56O"(191mm)

    56O"(165mm)

    56O"(191mm)

    RoughOpeningHeight

    6"(16mm)

    22"(559mm)

    56O"(572mm)

    56M"(667mm)

    RecessedNailingFlange

    Rough Opening Width 47"

    RoughOpeningDepth

    3"(76mm)

    3556M" (895mm)

    (1194mm)

    1456M"(362mm)

    36M"(95mm)

    Low VoltageWire Access

    Gas Line Access

    1456M"(362mm)

    Low VoltageWire

    Access

    Fireplace Dimensions

    Fig. 2 ODGSR42Aspecificationandframingdimensions.

    36"(914mm)

    40"(1016mm)

    396"(1007mm)

    6"(

    16mm)

    56O" (13mm)

    56O"

    6" (822mm)

    "(622mm)

    436M"(1111mm)

    856M"(210mm)

    56O"(165mm)

    56O"(191mm)

    Gas Line Access

    RoughOpeningHeight

    6"(16mm)

    22"(559mm)

    56O"(572mm)

    " (559mm)

    RecessedNailingFlange

    Rough Opening Width 41"

    RoughOpeningDepth

    36M"(95mm)

    (1041mm)

    3(6"(98mm)

    6856O"(

    1740

    mm)

    4856O" (1232mm)

    4856O"(1232mm)

    1456M"(362mm)

    36M"(95mm)

    Low VoltageWire Access 1456M"

    (362mm)

    Low VoltageWireAccess

    Fig. 1 ODGSR36Aspecificationandframingdimensions.

    Fireplace Dimensions

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    5/20

    5

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Moisture Resistance

    Thisoutdoorfireplacewillshedmoderateamountsof

    water,butisnotwaterproof.Waterandcondensingwa-

    tervapormayenterthechaseundercertainconditions.

    Thefireplacewillnotperformasanexteriorwall.Mois-

    turepenetrationmustbeconsideredforconstruction

    thatplacesthefireplaceinstructurewallsoronmois-

    turesensitivesurfaces.

    Wheninstalledonexteriorwalls:MHSCrecommends

    thefireplacechasebeconstructedoutsidethestruc-

    ture'sweatherenvelope.Wheretheplatformmeets

    thewall,useaflashingdetailsimilartothatrequired

    forattacheddecks.Chaseplatforms,includinghearths

    shouldslopeawayfromthestructureat1/4inperfoot.

    Thefireplacecanbeshimmedlevel.

    Wheninstalledonsurfaceswherewatermaycollector

    causedamage:MHSCrecommendsaslopeof1/8in

    to1/4inperfoottowardsthedrainportsuggested.The

    fireplacecanbeshimmedlevel.

    Hearthsshouldslopeawayfromthefrontofthefire-

    placeandchaseat1/8into1/4inperfoot.Metalsafety

    stripsmustbeontopofanycombustiblehearthmateri-

    alsusedformoisturemanagement.

    Clearance to Combustibles

    Appliances

    Top..........................................................0(0mm)

    Bottom.....................................................0(0mm)

    Side.........................................................0(0mm)

    Back........................................................0(0mm)

    PerpendicularSidewall...........................0(0mm)

    Topofunittoceiling..........................36(914mm)

    Frontofunittocombustibles.............36(914mm)

    Screened Porch Installation

    TheODGSRmaybeinstalledsafelyandisdesign

    certifiedbyCSAtobeinstalledinascreenedporchwith

    theseguidelines:

    Minimumporcharea..............................96sq.feet(9sqm)

    Minimumcelingheight..................................... 92"(234cm)

    Minimumoftwo(2)wallsmustbescreened

    Minimumtopofscreenheight,sidewalls........6'6"(198cm) Minimumscreenarea............................64sq.feet(6sqm)

    Mantels

    WARNING:A4"hoodmustbeusedifa

    mantelistobeinstalled.

    Theheightthatacombustiblemantelisfittedabovethe

    fireplaceisdependentonthedepthofthemantel.This

    alsoappliestothedistancebetweenthemantelleg(if

    fitted)andthefireplace.

    Forthecorrectmountingheightandwidthsreferto

    Figures3aand3b

    Noncombustiblemantelsandlegsmaybeinstalledat

    anyheightandwidtharoundtheappliance.

    When using paint or lacquer to finish the

    mantel, such paint or lacquer must be heat

    resistant to prevent discoloration.

    A B

    Y

    Z

    Fireplace

    Ref. Mantel Ref. Mantel From Top

    Shelf Depth of Comb. Chamber Y 8" (203mm) A 28" (711mm)

    Z 1"(38mm) B 26" (660mm)

    CFM146

    TopofCombustionChamber

    Fig. 3aMantelclearances.

    Side View

    StandoffMaintainminimum3/4"(19mm)clearancetocombustible.

    Hearth

    Ahearthisnotmandatorybutisrecommendedfor

    aestheticpurposes.Werecommendanoncombustible

    hearth.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    6/20

    6

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Framing and Finishing

    Check appliance to make sure it is levelled

    and properly positioned.

    Theapplianceshouldonlybemountedonthefollowing

    surfaces:

    Aflatcombustible(burnable)surface.

    Araisedwoodenplatform.

    Aconcreteblockorothersolidobjectplacedbeneatheachofthefourcornersoftheappliance.

    Tomounttheappliance:

    1.Chooseunitlocation.

    2.Four(4)nailingflangesaresuppliedwiththefire-

    place(foundonthefireplacehearth).Toleveltheboxandsecureitfirmlyinplace,removethenailing

    flangesfromthehearthandinstallatthesidesofthe

    fireplaceasshowninFigure4.

    Finishing

    CAUTION: All joints between the finished

    wall and the appliance surround (top and

    sides) may be sealed only with non-com-

    bustible material. Only noncombustible

    material can be applied as facing to the ap-

    pliance surround (the black painted face).Finishthewallwiththematerialofyourchoice.Referto

    Figures3aand3bforspecificclearanceswheninstall-

    ingacombustiblemantelorothercombustibleprojec-

    tion.

    FP549

    Fig. 4 Adjustabledrywallstrip(nailingflange).

    NailTopStandoffs

    NailSide-NailingFlanges

    J

    FG

    HI

    MantelLeg

    O

    N

    M

    LK

    Ref. Mantel Ref. Mantel Leg From

    Leg Depth of Comb. Opening

    F 14" (356mm) K 14" (356mm)

    G 12" (305mm) L 12" (305mm)

    H 10" (254mm) M 10" (254mm)

    I 8" (203mm) N 8" (203mm)

    J 1" (38mm) O 1" (38mm)

    BlackSurroundFace

    CFM164

    CFM170

    Fig. 3bCombustiblemantellegminimuminstallation.

    SideofCombustionChamber

    Moisture ResistanceThisoutdoorfireplacewillshedmoderateamountsof

    water,butisnotwaterproof.Waterandcondensingwa-

    tervapormayenterthechaseundercertainconditions.

    Thefireplacewillnotperformasanexteriorwall.Mois-

    turepenetrationmustbeconsideredforconstruction

    thatplacesthefireplaceinstructurewallsoronmois-

    turesensitivesurfaces.

    Wheninstalledonexteriorwalls:MHSCrecommends

    thefireplacechasebeconstructedoutsidethestruc-

    ture'sweatherenvelope.Wheretheplatformmeets

    thewall,useaflashingdetailsimilartothatrequired

    forattacheddecks.Chaseplatforms,includinghearthsshouldslopeawayfromthestructureat1/4inperfoot.

    Thefireplacecanbeshimmedlevel.

    Wheninstalledonsurfaceswherewatermaycollector

    causedamage:MHSCrecommendsaslopeof1/8in

    to1/4inperfoottowardsthedrainportsuggested.The

    fireplacecanbeshimmedlevel.

    Hearthsshouldslopeawayfromthefrontofthefire-

    placeandchaseat1/8into1/4inperfoot.Metalsafety

    stripsmustbeontopofanycombustiblehearthmateri-

    alsusedformoisturemanagement.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    7/20

    7

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Gas Inlet & Manifold Pressures

    Natural LP

    MinimumInletPressure 5.5w.c. 11.0w.c.

    MaximumInletPressure 14.0w.c. 14.0w.c.

    ManifoldPressure 3.5w.c. 10.0w.c.

    Gas Specification

    Max. Min.

    Model Fuel Gas Control Input Input

    ODGSR36ARN Nat. MillivoltHi/Lo 60,000 42,600

    ODGSR36ARP Prop. MillivoltHi/Lo 60,000 44,000

    ODGSR42ARN Nat. MillivoltHi/Lo 60,000 42,600

    ODGSR42ARP Prop. MillivoltHi/Lo 60,000 44,000

    High Elevations

    Input ratings are shown in BTU per hour and are

    certified without deration from elevations up to

    4,500 feet (1,370 m) above sea level.

    Nuisance outages may occur at altitudes above

    4,500 feet (1,370 m) if dirt, dust, lint and/or cob-webs are allowed to accumulate on burner and/or

    ODS pilot. Monthly inspection and cleaning is rec-ommended for altitudes above 4,500 feet (1,370 m)

    For elevations above 4,500 feet (1,370 m), instal-

    lations must be in accordance with the current

    ANSI Z223.1/NFPA 54 and/or local codes having

    jurisdiction.

    Valve Access

    Valveaccesscanbeaccomplishedinoneoftwoways:

    1. Removethefrontpaneljustbelowthefrontofthe

    hearthpan.Thisisaccomplishedbyliftingonthe

    panel.Toreplacethevalveaccesspanellineupthe

    twopinswiththeholesinthesurroundbottomandpushthepaneloverthefrontofthehearthpan.(Fig.

    5)

    2. LiftthebrickwiththeMajesticlogoonit.(Fig.6)

    ODGSR36A / ODGSR42A

    Certified to

    CSA 4-96

    FP1414

    Fig. 5Valveaccess.

    MajesticLogoBrick

    Fig. 6Liftbrickwithlogoonittoaccessvalve.

    FP1415

    1/2 (13 mm)

    NOTE:Wheninstallationis

    onahard,flatsurface(such

    asconcrete),thesurface

    mustbesloped1/4"perfoot

    awayfromanystructure.

    Blocking

    Hard,FlatSurface(i.e.concrete) FP1642a

    Fig. 7Exteriorchaseinstallation.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    8/20

    8

    ODGSR Series Outdoor Gas Fireplace

    20007114

    NailingFlange

    ValveAccessPanel

    Firebox

    Grate

    Screen

    Standoff

    Surround

    GasLineAc-cess

    FP1416

    Fig. 8Partsidentification.

    *Donotinstallheaderuntilunitisinplace.

    NailingFlange

    ValveAccessPanel

    Firebox

    Grate

    Screen

    Standoff

    Surround

    GasLineAccess

    *Donotinstallheaderuntilunitisinplace.

    Interiorsidesofanexteriorchase

    shouldbeweatherproof

    FP1644

    Fig. 9Exteriorchaseinstallation.

    Gas Line Installation

    Thisappliancemustbeisolatedfromthegassupply

    pipingsystembyclosingitsindividualmanualshutoff

    valveduringanypressureequaltoorlessthan1/2psig

    (3.45kPa).

    Theapplianceanditsindividualshutoffvalvemustbe

    disconnectedfromthegassupplypipingsystemduring

    anypressuretestingofthatsystemattestpressuresin

    excessof1/2psig(3.45kPa).

    Ifgaspipingfromthesourcetotheappliancelocation

    hasnotbeenaccomplished,installtherequiredpipe.

    Consultlocalplumbingcodetoassureproperpipesize.

    Thegaspipelinecanbebroughtinthroughtheright

    sideoftheappliance.Aknockoutisprovidedtoallow

    forthegaspipeinstallationandtestingofanygascon-

    nection.

    NOTE: Thegaslineconnectioncanbemadewith3/8"

    coppertubingapprovedforpropaneornaturalgas,1/2"

    rigidpipeoranapprovedflexconnector,thenreduced

    to3/8"totheappliance.Becausesomemunicipalities

    havesomeadditionallocalcodes,itisalwaysbestto

    consultyourlocalauthority.

    U.S.:ConsultthecurrentNationalFuelGasCode,ANSI

    Z223.1/NFPA54.

    Canada:CSA-B149.1installationcode.

    Testforleaks.Usea50/50solutionofliquidsoapand

    watertotestforleaksatgasfittingsandjoints.Apply

    water/soapsolutionwithbrushonly-donotoverapply.

    NEVER testwithanopenflame.

    Thegascontrolisequippedwithacapturedscrewtype

    pressuretestpoint,thereforeitisnotnecessarytopro-videa1/8"testpointupstreamofthecontrol.

    Whenusingcopperorflexconnectoruseonlyapproved

    fittings.Always provide a unionsothatgaslinecan

    beeasilydisconnectedforburnerorfanservicing.

    Seegasspecificationforpressuredetailsandratings.

    NOTE:Ifflexconnectorisused,itmustbekeptinside

    oftheappliance.(Fig.10)

    FP598

    Fig. 10 Typicalgassupplyinstallation.

    1/2"GasSupply

    1/2"x3/8"Shut-offValve

    3/8"Nipple

    3/8"Union

    3/8"Nipple

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    9/20

    9

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Remote Wall Switch

    NOTE:Useanapprovedoutdoorswitch.

    1.Threadwirethroughthelowvoltagewireaccesshole

    locatedoneithersideofunit.Donotcutwireorinsu-

    lationonmetaledges.Ensurethatwireisprotected.

    Runtheotherendtoaconvenientlylocatedwall

    receptaclebox.

    2.Attachwiretoswitchandinstallswitchintoreceptacle

    box.Attachcoverplatetoswitch.

    3.Connectwiringtogasvalve.RefertoFigure11.

    CAUTION: Do not wire millivolt remote

    wall switch for gas appliance to a 120v

    power supply.

    For lighting instructions, refer to Page 12.

    NOTE: If glass doors are installed, the unit must be

    operated with the doors fully open. (Fig. 12) If the

    doors are not fully open, the thermodisk will auto-

    matically turn the unit off.

    CAUTION: After the unit cools, the burner

    will automatically come on.

    OPEN

    Correct Wrong MD706-7

    Fig. 12Correctdoorpositionduringoperation.

    Pilot

    Thermodisk

    On/OffSwitch

    Valve

    HV105

    Fig. 11 Remoteswitchwiring.

    TPTH

    TH

    TP

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    10/20

    10

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Operating Instructions

    Log Installation

    1.Removelogsfromthepackaging.

    As with all plastic, these bags

    are not toys and should always

    be kept away from children andinfants.

    2.Placeleftrearlogonrearlogsupport.

    Ensurethatlogisfirmlypositionedand

    thereisnoside-to-sidemovement.(Figs.

    13&14)

    3.CarefullyplaceEmberLogbetween

    grateandburner.(Figs.13&14)

    4.Placethefrontofrightrearlogonthe

    burnerandthebackofthelogonthe

    rearlogsupport.

    5.Placethetoplogsontothelocator

    notches.Ensurethelogsaresecure.(Fig.13&14)

    First Firing

    Uponcompletingthegaslineconnection,asmall

    amountofairwillbetrappedintheline.When

    firstlightingtheunitwithpilotlight,itwilltakea

    fewminutestopurgethetrappedair.Oncepurg-

    ingiscomplete,thepilotandburnerwilllightand

    operateasindicatedintheinstructionmanual.

    Subsequentlightingsoftheappliancewillnot

    requirepurging.

    Whenlitforthefirsttime,theappliancewillemit

    aslightodorforanhourortwo.Thisisdueto

    paintandlubricantsusedinthemanufacturing

    process.Aftereachlighting,vapormaycon-

    denseandfogtheglass;thismoisturedisap-

    pearsinafewminutesofburning.

    RightCross

    Log

    LeftCross

    Log

    LeftRear

    Log

    RightRear

    Log

    Ember

    Log

    LG317

    Fig. 13ODGSR36logplacement.

    LeftRear

    Log

    LeftCross

    LogMiddleCrossLog

    RightCrossLog

    RightRear

    Log

    LogLeft

    Ember

    Grate

    Fig. 14ODGSR42Alogplacement.

    LG318

    LogRight

    Ember

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    11/20

    11

    ODGSR Series Outdoor Gas Fireplace

    20007114

    LG320

    Fig. 18ODGSR42Aflameappearance.

    Fig. 16Properpilotflameheight.

    FP581

    3/8"-1/2"

    NOVA SIT Pilot

    RedGlow LG319

    Fig. 17 ODGSR36Aflameappearance.

    Flame Adjustment

    ForunitsequippedwithHi/Lovalves,flameadjustment

    isaccomplishedbyrotatingtheHi/Loadjustmentknob

    locatednearthecenterofthegascontrol.

    LO

    HITurn

    counterclockwiseto increase

    flame height

    Turn clockwise

    to lower

    flame height

    Fig. 15FlameadjustmentknobforSIT820valve.

    Flame Characteristics

    Itisimportanttoperiodicallyperformavisualcheckof

    thepilotandtheburnerflames.Comparethemtotheil-

    lustrationsbelow(Figs.16,17,18).Ifanyoftheflames

    appearabnormalcallaserviceperson.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    12/20

    12

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Optional Weather Enclosure

    Anoptionalweatherenclosureisavailabletoprotect

    theburnerwhennotinuse.

    CAUTION:Donotusetheweatherenclosure

    iftheunithasglassdoorsinstalled.

    Installation Instructions

    1. TurntheunitOFFandallowtocool.

    2. Grabtheweatherenclosurebythehandle(s).

    3. Slidethetopoftheweatherenclosureupbetween

    thebackofthesurroundtopandthescreenrail.

    (Fig.19)

    4. Pushthebottomoftheweatherenclosureintothe

    fireboxjustenoughtoclearthevalveaccesscover

    andsetdown.(Fig.20)

    KT457

    Fig. 19Placetopofweatherenclosurebetweensurroundtop

    andscreenrail.

    SurroundTop

    WeatherEnclosureScreenRail

    Screen

    HearthBrick

    ValveAccessCover

    KT458

    Fig. 20Pushbottomofweatherenclosureintofirebox.

    Optional Stainless Steel Hood

    Anoptionalstainlesssteelhoodisavailableforboththe

    ODGSR36AandODGSR42A.

    NOTE: The stainless steel hood may NOT

    be used when the optional glass doors are

    installed.

    Installation Instructions:1. Turntheunitoffandallowtocool.

    2. Placethehoodsothe2B,"(67mm)slotclearsthe

    sensorplatelocatedunderthefireplaceopeningon

    thetopleftside.(Fig.21)

    3. Securethehoodtotheunitusingthethree(3)slots

    inthehoodandthepilotholesintheunitwiththe

    stainlesssteelsheetmetalscrewsprovided.(Fig.

    21)

    4. Alignthesidesofthehoodsothepilotholesonthe

    rightandleftsidesoftheunitareexposedthrough

    theslotsontheendsofthehood.Secureusingthe

    remainingstainlesssteelsheetmetalscrews.(Fig.21)

    StainlessSteelHood

    StainlessSteelSheet

    MetalScrews(5)

    SensorPlateSlot

    FP1635

    Fig. 21Securestainlesssteelhoodwithfive(5)sheetmetal

    screws.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    13/20

    13

    ODGSR Series Outdoor Gas Fireplace

    20007114

    3. Opencontrolaccesspanel.

    4. Pushingascontrolknobslightlyandturn

    clockwise to"OFF".Donotforce.

    5. Closecontrolaccesspanel.

    1. STOP!Readthesafetyinformationabove.

    2. TurnOFFallelectricalpowertothefireplace.

    3. ForMN/MP/TN/TPappliancesONLY,goonto

    Step4.ForRN/RPappliancesturntheOn/Off

    switchtoOFFpositionorsetthermostatto

    lowestlevel.

    4. Opencontrolaccesspanel.

    5. Pushingascontrolknobslightlyandturn

    clockwise to"OFF".

    10.Pushthecontrolknoballthewayinandhold.

    Immediatelylightthepilotbyrepeatedlydepress-

    ingthepiezosparkignitoruntilaflameappears.

    Continuetoholdthecontrolknobinforaboutone

    (1)minuteafterthepilotislit.Releaseknobandit

    willpopbackup.Pilotshouldremainlit.Ifitgoes

    out,repeatsteps5through8.

    Ifknobdoesnotpopupwhenreleased,stop

    FOR YOUR SAFETY READ BEFORE LIGHTING

    Ifyoucannotreachyourgassupplier,callthe

    FireDepartment

    C.Useonlyyourhandtopushinorturnthegas

    controlknob.Neverusetools.Iftheknobwillnot

    pushinorturnbyhand,donottrytorepairit,call

    aqualifiedservicetechnician.Applyingforceor

    anyattemptedrepairmayresultinafireorexplo-

    sion.

    D.Donotusethisfireplaceifanyparthasbeen

    underwater.Immediatelycallaqualifiedservice

    techniciantoinspecttheheaterandtoreplace

    anypartofthecontrolsystemandanygascontrol

    whichhasbeenunderwater.

    A. Thisheaterhasapilotwhichmustbelitmanu-

    ally. Whenlightingthepilotfollowthese

    instructionsexactly.

    B. BEFORELIGHTINGsmellallaroundthe

    heaterareaforgas.Besuretosmellnextto

    thefloorbecausesomegasisheavierthanair

    andwillsettleonthefloor.

    WHAT TO DO IF YOU SMELL GAS

    Donottrytolightanyfireplace

    Donottouchanyelectricswitch

    Donotuseanyphoneinyourbuilding

    Immediatelycallyourgassupplierfroma

    neighbor'sphone.Followthegassupplier's

    instructions.

    To Turn Off Gas to Heater

    Lighting and Operating Instructions

    1. TurntheOn/Offswitchto"OFF"positionorset

    thethermostattolowestsetting.

    2. Turnoffallelectricpowertothefireplaceif

    serviceistobeperformed.

    Lighting Instructions

    6. Waitfive(5)minutestoclearoutanygas.

    Thensmellforgas,includingnearthefloor.If

    yousmellgas,STOP!Follow"B"inthesafety

    informationabove.Ifyoudonotsmellgas,go

    tothenextstep.

    7. Removeglassdoorbeforelightingpilot.(See

    GlassFrameRemovalsection).

    8. Visiblylocatepilotbythemainburner.9. Turnknobongascontrolcounterclockwise

    to"PILOT".

    andimmediatelycallyourservicetechnicianor

    gassupplier.

    Ifafterseveraltries,thepilotwillnotstaylit,

    turnthegascontrolknobto"OFF"andcallyour

    servicetechnicianorgassupplier.

    11.Replaceglassdoor.

    12.TurngascontrolknobtoONposition.

    13.ForRN/RPappliancesturntheOn/Offswitchto

    ONpositionorsetthermostattodesiredsetting.14.Turnonallelectricalpowertothefireplace.

    WARNING:If you do not follow these instructions exactly, a fire or explosion

    may result causing property damage, personal injury or loss of life.

    Euro SIT SIT NOVA Honeywell

    PILO

    T

    ON

    OFF

    ON

    PILOT

    OF

    F

    OFF

    543

    2

    1

    OFF

    Pi

    lot

    3/8" - 1/2"

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    14/20

    14

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Troubleshooting

    FP396

    Gas Supply On Supply Line Hooked upShutoff Valve OpenNO

    NO

    NO

    NO

    Lockout has engaged. Wait 60

    seconds and try again.

    Piezo not tight enough for goodground.

    For spark at electrode while

    depressing Piezo (Red Button)

    1/8" gap to pilot hood needed.All wiring connections

    Replace Piezo IgnitorThermodisk

    For Air in the lines

    Thermopile needs a minimum

    325mV. Adjust pilot flame height.

    All wiring connectionsReplace Thermopile

    Thermocouple needs a minimum

    of 14mV.

    Defective valve. Turn to pilot,

    meter should read greater than100mV.

    Thermodisk

    Pilot Lights with

    Piezo Ignitor

    YES

    YES

    YES

    YES

    Pilot Stays Lit

    Pilot Lights Main

    Burner

    System OK

    START

    CHECK

    Wall switch is not turned on.

    Watch for grounded wires!

    Thermopile needs a minimum

    325mVPlugged burner orifice

    Doors not fully open (Fig. 10)

    Nova SIT 820 Standing Pilot

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    15/20

    15

    ODGSR Series Outdoor Gas Fireplace

    20007114

    Maintenance

    Burner and Burner Compartment

    Itisimportanttokeeptheburnerandtheburner

    compartmentclean.Atleastonceperyearthelogs

    shouldberemovedandtheburnercompartment

    vacuumedandwipedout.Removeandreplacethelogs

    aspertheinstructionsinthismanual.

    Always handle the logs with care as they are fragile

    and may also be hot if the fireplace has been in

    use.

    Cleaning

    Therearethreemethodsofcleaningthepolishedstain-

    lesssteelofyouroutdoorfireplace;

    1. Warm,soapywater-toloosenanydirtfilm

    2. Glasscleanerwithammonia

    3. Stainlesssteelcleaneravailableathardwarestores

    Regardlessofwhichmethodisused,rememberthatanythingwithtoomuchabrasivemaydullthefinish.

    Cleaning the Standing PilotControl System

    Theburnerandcontrolsystemconsistsof:

    mainburner

    gasorifice

    pilotburner

    thermopile

    combinationmillivoltgasvalve

    Mostofthesecomponentsmayrequireonlyanocca-

    sionalcheckupandcleaningandsomemayrequiread-

    justment.Ifrepairisnecessary,itshouldbeperformed

    byaqualifiedtechnician.

    Inordertoproperlycleantheburnerandpilotassembly

    turnoffthegastotheunit,removelogsexposingthe

    burnerandpilotassembly.Cleanallforeignmaterials

    fromthetopoftheburner.Checktomakesurethatburnerpartsareclean.Visuallyinspectpilot.Brushor

    blowawayanydustorlintaccumulationIfpilotorificeis

    plugged,disassemblymayberequiredtoremoveany

    foreignmaterialfromtheorificeortubing.

    Toobtainproperoperation,itisimperativethatthepilot

    andburner'sflamecharacteristicsaresteady,notlifting

    orfloating.

    Typically,thetop3/8"or1/2"ofthethermopileshould

    beengulfedinthepilotflame.(Fig.16)

    Toadjustpilotburner,turnpilotscrewmarked"pilot"for

    properflamesize.

    Theairshutterissetatfactorynoadjustmentshouldbe

    necessary.

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    16/20

    16

    ODGSR Series Outdoor Gas Fireplace

    20007114

    4a/b

    11

    13

    HI

    LO

    OFF

    ON

    OFF

    EA

    PILOT

    THTP

    TP

    TH

    14

    12a/b

    16

    15

    18a/b

    69 10

    a b

    d

    c

    h

    c

    d

    a

    b

    f

    e

    2

    3

    7

    8

    17

    20

    g

    19a/b

    21

    22

    25

    ODGSR36A, ODGSR42A Ref. Description ODGSR36A ODGSR42A

    1. Logs-CompleteSet 20007180 20007200

    1a. Log-LeftRear 20007175 20007193

    1b. Log-RightRear 20007176 20007194 1c. Log-RightCross 20007178 20007197

    1d. Log-LeftCross 20007177 20007195

    1e. Log-MiddleCross -- 20007196

    1f. Log-LeftEmber -- 20007198

    1g. Log-RightEmber -- 20007199

    1h. FrontEmberLog 20007179 --

    2. BurnerHousingAssembly 20007119 20007187

    3. CeramicTile(single) 57803 57803

    4a. BurnerOrifice-Natural(Manifold&Orifice) 20007106 20007106

    4b. BurnerOrifice-LP(Manifold&Orifice) 20007159 20007159

    6. SideBrick-Left* 20002008or92D0004 20002021or92D0011

    7. BackBrick* 20002006or92D0002 20002019or92D0005

    8. SideBrick-Right* 20002007or92D0003 20002020or92D0006

    9. LeftHearthBrick* 20007158or92D0008 20007241or92D0010

    10. RightHearthBrick* 20007157or92D0007 20007240or92D0009

    11. Piezo 52464 52464

    12a. PilotTopConvertible-Natural(3WayAssembly) 10002264 10002264

    12b. PilotTopConvertible-LP(3Wayassembly) 10002265 10002265

    13. Thermopile18" 7533113 7533113

    MHSCreservestherighttomakechangesindesign,materials,specifications,pricesanddiscontinuecolorsandproductsatanytime,without

    notice.

    7114

    1.ODGSR36ALogs 1.ODGSR42ALogs

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    17/20

    17

    ODGSR Series Outdoor Gas Fireplace

    20007114

    ODGSR36A, ODGSR42A (continued)Ref. Description ODGSR36A ODGSR42A

    14. PilotTubing 10001296 10001296

    15. CableIgnitor24" 7522432 7522432

    16. Thermocouple24" 7531137 7531137

    17. Grate 20006819 20006819

    18a. PilotOrifice-Natural 10002268 10002268 18b. PilotOrifice-LP 10002269 10002269

    19a. ValveNOVA-Natural 7529141 7529141

    19b. ValveNOVA-LP 7529142 7529142

    20a. AirShutter-Natural 20009120 20000129

    21. HearthBrickCover 20007183or92D0016 20007183or92D0016

    22. Thermodisk 20007568 20007568

    23. ConversionKitLPtoNatural 20008549 20008550

    24. ConversionKitNaturaltoLP 20008548 20008551

    25. ValveAccessPanelAssy 20009119 20008296

    ContactMHSCforquestionsconcerningpricesandpolicies

    coveringreplacementparts.Partsmaybeorderedthrough

    yourMajesticFireplacesdistributorordealer.

    Youwillneedthefollowinginformationwhenorderingre-

    placementparts:

    1. Theappliancemodelnumber.

    2. Theserialnumber.

    3. Adescriptionofthepart.

    Shouldyouneedadditionalinformationbeyondwhatyour

    dealercanfurnish,contact:

    MHSC

    149ClevelandDrive

    Paris,KY40361

    Modelandserialnumbersarelistedontherat-

    ingplate(locatedonrightsideofcombustion

    chamber).

    Recordyourmodelandserialnumbersherefor

    futurereference:

    Model# ____________________________

    Serial# ____________________________

    *Whenorderingreplacementfirebrick,checktheserialnumberandplantcodeofthefireplace,locatedontheUL

    labelinsidethefirebox.Serialnumbers/plantcodewitha'P'requirethefirebricklistedfirstundertherespective

    fireplace(whitebrick).Serialnumbers/plantcodewithan'X'requirethefirebricklistedsecondundertherespective

    fireplace(greybrick).

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    18/20

    18

    ODGSR Series Outdoor Gas Fireplace

    20007114

    AccessoriesThefollowingaccessoriesareavailablefromyourlocalMajesticFireplacesdistributor.Eachaccessorycomeswith

    aseparateinstallationinstructionformountingtotheparticularfirebox.Besuretoreadeachinstructionthoroughly

    beforeinstalling.

    CAUTION: This firebox is a highly engineered system, and, as such, must be operated only with MHSC ap-

    proved components. If you use an unapproved component to make any modifications, you may create a pos-

    sible fire hazard and will void the MHSC warranty. In addition, such action may void the coverage provided by

    the owner's insurance.

    Accessory Description Model Number

    4"StainlessSteel Forheaterupto40,000BTU'sandmantels UV36SH4

    Hood 8"highby12"wide UV42SH4

    GlassDoors Designedtoenhancethelookofthefireplace 36GDKSSSR

    42GDKSSSR

    WeatherEnclosure Designedtoprotecttheburnerwhenunitisnotinuse ODG36WE

    ODG42WE

    DrainPan Designedtobeinstalledunderunittoshedwater 20014194(36"models)

    bymeansofcontainingandpipingwayfromstructure 20014195(42"models)

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    19/20

    19

    ODGSR Series Outdoor Gas Fireplace

    20007114

    LIMITED WARRANTYFactory-Build Fireplace and Components

    (Except Blowers)

    What is Covered and For How Long

    Five-Year Coverage:Forfiveyearsfromthedatethisfireplaceandcomponentsarefirstpurchasedforuse,MHSC

    will,atitsoption,repairorreplaceanydefectivepartofthisfireplaceorcomponents,orrefundtoyouasumnottoexceedthefactoryretailpriceineffectatthetimeofpurchase.

    Ten-Year Coverage:Fromthesixththroughthetenthyearfollowingthedatethisfireplaceoraccessoryisfirst

    purchasedforuse,MHSCwillmakeavailabletoyou,atourfactory,afreereplacementforanydefectivepartinthis

    fireplaceoraccessory.

    Twenty-Five-Year Availability of Replacement Parts:Fromtheelevenththroughthetwenty-fifthyearfollowingthe

    datethisfireplaceoraccessoryisfirstpurchasedforuse,MHSCwillmakeavailableatourfactoryreplacementparts

    forthisfireplaceoraccessory,whichyoumaypurchaseforthelistpricecurrentatthetimeyourpurchaseorderis

    received.

    What is Not Covered

    Thislimitedwarrantydoesnotcover:

    Transportationorshippingcost.

    Thecostofaservicecalltodiagnosetrouble.

    Paintedsurfaces.

    Damageordefectcausedbyimproperinstallation,accident,misuse,abuseoralteration.

    Poorventilationofsmokeorgasescausedbyair-conditioningandheatingsystems,exhaustfans,orpressuredif-

    ferentialsproducedbywind.

    Brokenglasscomponents.

    Cracksinceramicandcastablepartsthatdonotaffectsafeoperation.

    Wedonotwarrantthisfireplacetobeincompliancewithyourlocalbuildingcode.Buildingcodesvarygreatly

    throughoutthecountry,andyoushoulddeterminewhetheryourlocalbuildingcodecontainsrestrictionsontheuse

    ofthisfireplacebeforeyoupurchaseit.

    Blowersorfans,whicharewarrantedseparately.

    Heatlossduetothepassageofheatorairthroughoraroundthefireplace.

    Also,underourfiveyearcoverage,wedonotpaythecostofremovalandreplacementofanyportionofthestructureinwhichthefireplaceissituated,madenecessarybytherepair,removalorre-installationofthefireplace.

    Andunderourtwenty-fiveyearwarrantyofavailabilityofreplacementparts,weonlypromisetomaintainasupplyof

    replacementpartsatourfactoryforyoutopurchase.

    Limitations and Exclusions

    1. Noonehasauthoritytoaddtoorvarythislimitedwarranty,ortocreateforMHSCanyotherobligationsofliability

    inconnectionwiththisfireplaceandaccessory.

    2. MHSCshallnotbeliableforincidental,consequential,specialorcontingentdamagesyoumightsufferasaresult

    ofitsbreachofthiswrittenwarrantyoranyimpliedwarranty.Somestatesdonotallowtheexclusionoflimitationof

    incidentalorconsequentialdamages,sotheabovelimitationsmaynotapplytoyou.

    3. ThiswarrantyappliesonlytoafireplacesoldandusedintheUnitedStates.

    Forinformationaboutthiswarranty,contact: MHSC

    149 Cleveland Drive

    Paris, Kentucky 40361

  • 8/22/2019 Majestic Outdoor Fireplace Manual

    20/20

    MHSC149ClevelandDriveParis,Kentucky40361

    www.mhsc.com