    OPTIMASS / 400

    1000 Series Twin Straight Tube Coriolis Mass Flowmeter

    2000 Series Twin Straight Tube Coriolis Mass Flowmeter

    3000 Series Single Z Tube Coriolis Mass Flowmeter

    6000 Series Twin U Tube Coriolis Mass Flowmeter

    7000 Series Single Straight Tube Coriolis Mass Flowmeter

    MFC 400 Mass Flow Converter

    Guidelines for the use of Coriolis meters in hazardous areas

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    2/28

    2

    1. Introduction

    1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

    1.2 MFC 400F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

    1.3 OPTIMASS 1000 / 1000F / 1400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

    1.4 OPTIMASS 2000 / 2000F / 2400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

    1.5 OPTIMASS 3000 / 3000F / 3400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

    1.6 OPTIMASS 6000 / 6000F / 6400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

    1.7 OPTIMASS 7000 / 7000F / 7400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

    1.8 Data Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

    2. Temperature limits

    2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

    2.2 MFC 400F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

    2.3 OPTIMASS 1000 / 1000F / 1400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112.4 OPTIMASS 2000 / 2000F / 2400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

    2.5 OPTIMASS 3000 / 3000F / 3400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

    2.6 OPTIMASS 6000 / 6000F / 6400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

    2.7 OPTIMASS 6000F (high temperature) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

    2.8 OPTIMASS 7000 / 7000F / 7400C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

    2.9 Painted options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

    3. Connection of separated systems

    3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

    3.2 Cable parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

    3.3 Equipotential bonding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

    3.4 Terminal diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

    4. Electrical connections

    4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

    4.2 Non-Ex I signal I/O connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

    4.3 Ex i signal I/O connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

    5. Service and maintenance

    5.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245.2 Replacement of mains fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

    5.3 Returning the device for service or repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

    Appendix 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

    OPTIMASSCONTENTS

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    3/28

    3

    Do not install, operate or maintain this device without reading, understanding and followingthe factory supplied handbook. Failure to do so, may result in injury or damage.

    Read these instructions carefully before starting installation and save them for futurereference.

    Observe all warnings and instructions marked on the device. You MUST only use a power supply that has a protective earth.

    Do not use the device with the covers removed!

    You MUST follow the installation instructions in the handbook, paying particular attentionto:

    Handling

    Lifting

    Supporting and fixing the meter

    Cabling and connections.

    If the product does not operate normally, refer to the handbook or consult a qualifiedKROHNE service engineer. There are no operator-serviceable parts inside the product.

    Explanation of Symbols Used

    The following is a guide to the meaning of the symbols used in this handbook.The symbols fallinto two types. The rectangular symbols with blue background draw the readers attention togeneral points of information. The triangular symbols with yellow background draw the read-ers attention to hazards or hazardous situations.

    General InformationInformation is important to theinstallation/operation of the meter.

    General Warning Risk of damage to the meter or installation.

    EX - Hazardous Area WarningInstruction MUST be observed in order tocomply with Hazardous Areas Certification.

    High Voltage Risk of electric shock.

    General Hazard Non specific hazard that could result in injury.

    Hot Surface or High Temperature Risk of burning.

    Heavy Item Risk of injury.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    4/28

    4

    These terms may appear in this manual or on the device:

    Warning statement: Identify conditions or practices that could result in injury or loss of life.

    or

    Caution statement: Identify conditions or practice that could result in damage to the instru-ment or other property.

    Disclaimer:

    This document contains important information on the device. KROHNE attempts to be asaccurate and up-to-date as possible but assumes no responsibility for errors or omissions.Nor does KROHNE make any commitment to update the information contained herein. Thismanual and all other documents are subject to change without prior notice.

    KROHNE will not be liable for any damage of any kind by using this device, including, butnot limited to: direct; indirect; incidental; punitive and consequential damages.

    Any device purchased from KROHNE is warranted in accordance with the relevant productdocumentation and our Terms and Conditions of Sale.

    KROHNE reserves the right to alter the content of its documents, including this disclaimerin any way, at any time, for any reason, without prior notification and will not be liable in anyway for possible consequences of such changes.

    Product liability and Warranty

    Responsibility for suitability and intended use of this device rests solely with the user.Improper installation and operation of the device may lead to loss of warranty.

    In addition, the Terms and Conditions of Sale are applicable and are the basis for the pur-chase contract.

    If a device needs to be returned to KROHNE, please note the information given at the backof the Handbook. KROHNE regrets that they cannot repair or service a device unlessaccompanied by the completed form

    This instrument has been developed and manufactured by:

    KROHNE Ltd

    Rutherford DrivePark Farm Industrial EstateWellingboroughNorthantsNN8 6AEUnited Kingdom

    For information, maintenance or service, please contact your nearest local KROHNE represen-tative.

    See www.krohne.com

    WARNING

    No changes may be made to the devices. Unauthorized changes might affect the explosionsafety of the devices. Be sure to follow these instructions!

    IMPORTANT

    The prescriptions, regulations and electrical data described in the EC type examinationcertificate MUST be obeyed.

    In addition to the general regulations for low-voltage installations (e.g.HD384) theregulations laid down in the standard for electrical installations in gas hazardous areas(e.g. IEC/EN 60079-14) or dust hazardous areas (e.g. IEC/EN 61241-14) MUST be compliedwith.

    Installation, commissioning, utilization and maintenance must be carried out only bypersonnel trained in explosion safety.

    This manual must be read in conjunction with the OPTIMASS / OPTIGAS Handbooks.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    5/28

    5

    OPTIMASS1 INTRODUCTION

    For Ex i outputs

    Ex d connection compartment Ex e connection compartment

    II 2(1) G Ex d [ia Ga] IIC T6 Gb II 2(1) G Ex de [ia Ga] IIC T6 Gb

    II 2(1) D Ex t [ia Da] IIIC T75C Db II 2(1) D Ex ib t [ia Da] IIIC T75C DbFor non-Ex i outputs

    II 2 G Ex d [ia] IIC T6 Gb II 2 G Ex de [ia] IIC T6 Gb

    II 2 D Ex t IIIC T75C Db II 2 D Ex t IIIC T75C Db

    1.1 General

    The OPTIMASS flowmeter system consists of a mass flow sensor and a mass flow converter ora mass flow sensor and associated apparatus.

    The separate mass flow sensor with a mass flow converter is identified as:

    OPTIMASS 1000 flow sensor with MFC 400F flow converter; see PTB XX ATEX XXXX X OPTIMASS 2000 flow sensor with MFC 400F flow converter; see PTB XX ATEX XXXX X

    OPTIMASS 3000 flow sensor with MFC 400F flow converter; see PTB XX ATEX XXXX X

    OPTIMASS 6000 flow sensor with MFC 400F flow converter; see PTB XX ATEX XXXX X

    OPTIMASS 7000 flow sensor with MFC 400F flow converter; see PTB XX ATEX XXXX X

    The flowmeter in a compact configuration is identified as:

    OPTIMASS 1400C (OPTIMASS 1000 + MFC400 ); see PTB XX ATEX XXXX X

    OPTIMASS 2400C (OPTIMASS 2000 + MFC400 ); see PTB XX ATEX XXXX X

    OPTIMASS 3400C (OPTIMASS 3000 + MFC400 ); see PTB XX ATEX XXXX X

    OPTIMASS 6400C (OPTIMASS 6000 + MFC400 ); see PTB XX ATEX XXXX X

    OPTIMASS 7400C (OPTIMASS 7000 + MFC400 ); see PTB XX ATEX XXXX X

    All OPTIMASS sensors (separate and compact) and converters are available with a painted fin-ish for aggressive environments. For these meters, the model name has the suffix -Painted

    Example: OPTIMASS 1400C-Painted

    The output configuration of the MFC400 is described by the CG33.XYZ number listed on thedata label. See section 4 for a detailed description.

    All types are intended for use in Zone 1 Category 2.All types (except OPTIMASS3000/3000F/3400C) are also intended for Zone 0 Category 1 areas. Refer to the Ex markingstable for each meter. In addition, certain versions of MFC400 have intrinsically safe signal out-

    puts suitable for use in Category 1 areas.

    1.2 MFC 400F

    The MFC 400F has intrinsically safe connections to the mass flow sensor with either increasedsafety or intrinsically safe signal outputs. The signal output connection compartment can beconfigured with protection type Ex d or Ex e. The marking is as follows:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    6/28

    6

    For non-Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2 G Ex d ia IIC T6....T1 Ga/Gb II 1/2 G Ex de ia IIC T6....T1 Ga/Gb

    II 2 D Ex t IIIC T165C Db II 2 D Ex t IIIC T165C Db

    For Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2(1) G Ex d ia [ia Ga] IIC T6....T1 Ga/Gb II 1/2(1) G Ex de ia [ia Ga] IIC T6....T1 Ga/Gb

    II 2(1) D Ex t [ia Da] IIIC T165C Db II 2(1) D Ex t [ia Da] IIIC T165C Db

    1.4 OPTIMASS 2000 / 2000F / 2400C

    The OPTIMASS 2000 / 2000F mass flow sensors / mass flow meters are designed withintrinsically safe protection type. The marking for the OPTIMASS 2000 / 2000F (with or withoutheating jacket / insulation) is as follows:

    II 1 G Ex ia IIC T6...T1 Ga

    II 1 D Ex ia IIIC T160C Da

    The marking for the compact OPTIMASS 2400C is as follows:

    For non-Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2 G Ex d ia IIC T6....T1 Ga/Gb II 1/2(1) G Ex de ia IIC T6....T1 Ga/Gb

    II 2 D Ex t IIIC T160C Db II 2 D Ex t IIIC T160C Db

    For Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2(1) G Ex d ia [ia Ga] IIC T6....T1 Ga/Gb II 1/2(1) G Ex de ia [ia Ga] IIC T6....T1 Ga/Gb

    II 2(1) D Ex t [ia Da] IIIC T160C Db II 2(1) D Ex t [ia Da] IIIC T160C Db

    1.3 OPTIMASS 1000 / 1000F / 1400C

    The OPTIMASS 1000 / 1000F mass flow sensor / mass flow meter is designed with intrinsicallysafe protection type. The marking for the OPTIMASS 1000 / 1000F (with or without heating jack-et / insulation) is as follows:

    II 1 G Ex ia IIC T6...T1 Ga

    II 1 D Ex ia IIIC T165C Da

    The marking for the compact OPTIMASS 1400C is as follows:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    7/28

    7

    For non-Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 2 G Ex d ia IIC T6....T1 Gb II 2 G Ex de ia IIC T6....T1 Gb

    II 2 D Ex t IIIC T165C Db II 2 D Ex t IIIC T165C Db

    For Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 2(1) G Ex d ia [ia Ga] IIC T6....T1 Gb II 2(1) G Ex de ia [ia Ga] IIC T6....T1 Gb

    II 2(1) D Ex t [ia Da] IIIC T165C Db II 2(1) D Ex t [ia Da] IIIC T165C Db

    1.6 OPTIMAS 6000 / 6000F / 6400C

    The OPTIGAS 6000 / 6000F mass flow sensor / mass flow meter is designed with intrinsicallysafe protection type. The marking for the OPTIGAS 6000 / 6000F (with or without heating jacket/ insulation) is as follows:

    II 1 G Ex ia IIC T6...T1 Ga

    II 1 D Ex ia IIIC T270C Da

    The marking for the compact OPTIMAS 6400C is as follows:

    1.5 OPTIMASS 3000 / 3000F / 3400C

    The OPTIMASS 3000 / 3000F mass flow sensors / mass flow meters are designed withintrinsically safe protection type. The marking for the OPTIMASS 3000 / 3000F (with or withoutheating jacket / insulation) is as follows:

    II 1 G Ex ia IIC T6...T1 Ga

    II 1 D Ex ia IIIC T165C Da

    The marking for the compact OPTIMASS 3400C is as follows:

    For non-Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2 G Ex d ia IIC T6....T1 Ga/Gb II 1/2 G Ex de ia IIC T6....T1 Ga/Gb

    II 2 D Ex t IIIC T270C Db II 2 D Ex t IIIC T270C Db

    For Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2(1) G Ex d ia [ia Ga] IIC T6....T1 Ga/Gb II 1/2(1) G Ex de ia [ia Ga] IIC T6....T1 Ga/Gb

    II 2(1) D Ex t [ia Da] IIIC T270C Db II 2(1) D Ex t [ia Da] IIIC T270C Db

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    8/28

    8

    For Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2(1) G Ex d ia [ia Ga] IIC T6....T1 Ga/Gb II 1/2(1) G Ex de ia [ia Ga] IIC T6....T1 Ga/Gb

    II 2(1) D Ex t [ia Da] IIIC T165C Db II 2(1) D Ex t [ia Da] IIIC T165C Db

    For non-Ex i signal outputs with or without heating jacket / insulation

    Ex d connection compartment Ex e connection compartment

    II 1/2 G Ex d ia IIC T6....T1 Ga/Gb II 1/2 G Ex de ia IIC T6....T1 Ga/Gb

    II 2 D Ex t IIIC T165C Db II 2 D Ex t IIIC T165C Db

    1.7 OPTIMASS 7000 / 7000F / 7400C

    The OPTIMASS 7000 / 7000F mass flow sensors / mass flow meters are designed withintrinsically safe protection type. The marking for the OPTIMASS 7000 / 7000F (with or withoutheating jacket / insulation)is as follows:

    II 1 G Ex ia IIC T6....T1 Ga

    II 1 D Ex ia IIIC T165C Da

    The marking for the compact OPTIMASS 7400C is as follows:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    9/28

    9

    7

    81

    2

    3

    5

    4

    6

    1.8 Data Plates

    The data plate on the connection box of separate mass flow sensors typically contains the fol-lowing information:

    1 Company logo and address

    2 Model/size

    3 Year of Manufacture

    4 Serial Number

    5 Handbook Publication Number6 Identification Number of the notified body, as required by Directive 94/95 EC, Annex IV

    7 Ex Specific Requirements (example shown)

    8 Certificate Number

    9 Ex Marking (Example Shown)

    1 Company Logo and Address

    2 Model/size

    3 Date of Manufacture

    4 Serial Number

    5 Handbook Publication Number

    6 Power Supply Data

    7 Ex Specific Requirements

    8Certificate Number

    9 Ex Marking (Example Shown)

    0 Identification Number of the notified body, as required by Directive 94/95 EC, Annex IV

    6

    0

    8

    7

    9

    9

    1

    2

    3

    5

    4

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    10/28

    10

    OPTIMASS2 TEMPERATURE LIMITS

    IO Configuration (last three characters) Designation

    100 Basic IO

    488, 4C8 to 4K8

    688, 6C8 to 6K8

    788, 7C8 to 7K8

    Modular IO and Module Carrier with 1 modulepulse / status or control in

    888, 8C8 to 8K8B88, BC8 to BK8

    C88, CC8 to CK8

    Modular IO and Module Carrier with 1 modulepulse / status

    D88 to DP8

    E88 to EP8Profibus PA or Foundation Fieldbus andModule Carrier with 1 module (all modules)

    F80,

    FCO to FKO

    Profibus DP and Module Carrier with 1 mod-ule Pulse / Status or Control In

    G88 to GP8MODBUS IO and Module Carrier with 1 mod-ule (all modules)

    GCC to GKC, GCE to GKC

    GCF to GKFHCC to HKC, HCE to HKC

    HCF to HKF

    Modbus IO and Module Carrier with 2 modulepulse / status or control in

    200 300 Exi IO

    2.1 General

    Due to the influence of the media temperature, mass flow sensors and compact mass flowmeters are not allocated to any fixed temperature class. For allocation regarding thenon-insulated and heated/insulated versions, please refer to the tables below.

    The temperature limits below apply under the following conditions:

    The flowmeter is installed and operated in accordance with the installation directions givenin the Installation and Operating Instructions.

    The flowmeter is not heated up by any additional heat radiation (direct solar radiation, heatfrom adjacent plant parts) so causing it to operate above the permissible ambient tempera-ture range.

    Insulation is not hindering free ventilation of the mass flow converter housing.

    2.2 MFC 400F

    The MFC 400F mass flow converter is suitable for temperature classes T6.T1 with amaximum surface temperature T75 C. with the following restictions on ambient temperature:

    1 Aluminium converter housing:

    Tamb: - 40C...+65C

    2 Stainless steel converter housing:

    Tamb: - 40C...+60C

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    11/28

    11

    OPTIMASS 1400C with SS converter housing, with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T75

    55 T5 T90

    90 T4 T125

    130 T3 T1 T165

    5055 T5 T90

    90 T4 T1 T125

    60 60 T5 T1 T95

    OPTIMASS 1400C with aluminium converter housing, with or without heatingjacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T75

    55 T5 T90

    90 T4 T125

    130 T3 T1 T165

    5055 T5 T9090 T4 T125

    130 T3 T1 T165

    65 65 T4 T1 T100

    OPTIMASS 1000 / 1000F - with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T7555 T5 T90

    90 T4 T125

    130 T3-T1 T165

    50

    55 T5 T90

    90 T4 T125

    130 T3-T1 T165

    6575 T4 T110

    130 T3-T1 T165

    The cable supplied by KROHNE is designed for a continuous working temperature of up to 85C. Alternativecabling must be a heat-resistant type with a continuous minimum working temperature of 85C.

    2.3 OPTIMASS 1000 / 1000F / 1400CThe OPTIMASS 1000 / 1000F / 1400C is suitable for temperature classes T6.T1 according tothe following tables:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    12/28

    12

    OPTIMASS 2400C with SS converter housing, with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T70

    55 T5 T85

    90 T4 T120

    130 T3 T1 T160

    5055 T5 T85

    90 T4 T1 T120

    60 60 T5 T1 T90

    OPTIMASS 2400C with aluminium converter housing, with or without heatingjacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T70

    55 T5 T85

    90 T4 T120

    130 T3 T1 T160

    50

    55 T5 T85

    90 T4 T120

    130 T3 T1 T160

    65 65 T5 T1 T95

    OPTIMASS 2000 / 2000F - with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T70

    55 T5 T85

    90 T4 T120

    130 T3-T1 T160

    50

    55 T5 T85

    90 T4 T120

    130 T3-T1 T160

    6565 T5 T95

    130 T3-T1 T160

    2.4 OPTIMASS 2000 / 2000F / 2400C

    The OPTIMASS 2000 / 2000F / 2400C are suitable for temperature classes T6.T1 according tothe following tables:

    The cable supplied by KROHNE is designed for a continuous working temperature of up to85C. Alternative cabling must be a heat-resistant type with a continuous working temperatureof 85C.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    13/28

    13

    OPTIMASS 3400C with SS converter housing, with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T55

    70 T5 T85

    90 T4 T105

    130 T3 T1 T145

    5070 T5 T85

    90 T4 T1 T105

    60 60 T6 T1 T75

    OPTIMASS 3400C with aluminium converter housing, with or without heatingjacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T55

    70 T5 T85

    90 T4 T105

    150 T3 T1 T165

    5090 T4 T105

    145 T3 T1 T160

    65 65 T6 T1 T80

    OPTIMASS 3000 / 3000F - with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T55

    70 T5 T85

    90 T4 T105

    150 T3-T1 T165

    50

    70 T5 T85

    90 T4 T105

    150 T3-T1 T165

    6590 T4 T105

    130 T3-T1 T145

    2.5 OPTIMASS 3000 / 3000F / 3400C

    The OPTIMASS 3000 / 3000F / 3400C is suitable for temperature classes T6.T1according to the following tables:

    The cable supplied by KROHNE is designed for a continuous working temperature of up to85C. Alternative cabling must be a heat-resistant type with a minimum continuous workingtemperature of 85C.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    14/28

    14

    OPTIMASS 6400C with aluminium converter housing, with or without heatingjacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T80

    150 T3 T190

    230 T2 - T1 T270

    50

    40 T6 T80

    150 T3 T190

    230 T2 - T1 T270

    65 65 T4 T1 T105

    Low temperature version

    -25...65 -200...40 T6-T1 T80

    OPTIMASS 6000 / 6000F - with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    4040 T6 T80

    150 T3 T190

    230 T2-T1 T270

    55

    40 T6 T80

    150 T3 T190

    230 T2-T1 T270

    65

    40 T6 T80

    150 T3 T190

    230 T2-T1 T270Low temperature version

    -20...65 -200...40 T6-T1 T80

    OPTIMASS 6400C with SS converter housing, with or without heating jacket / insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    40

    40 T6 T80

    150 T3 T190

    230 T2-T1 T270

    50

    40 T6 T80

    150 T3 T190

    230 T2 T1 T270

    60 60 T4 T1 T100

    Low temperature version

    -25...60 -200...40 T6-T1 T80

    2.6 OPTIMASS 6000 / 6000F / 6400C

    The OPTIMASS 6000 / 6000F / 6400C is suitable for temperature classes T6.T1according to the following tables:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    15/28

    15

    OPTIMASS 6000F with aluminium or SS junction box and with or without heating jacket /insulation

    AmbientTemp. Tamb C

    Max. mediumtemp. Tm C

    TemperatureClass

    Max. SurfaceTemp. C

    -40...40

    40 T6 T80

    230 T2 T270

    400 T1 T440

    -40...55

    40 T6 T80

    230 T2 T270

    400 T1 T440

    -40...65

    40 T6 T80

    230 T2 T270

    400 T1 T440

    2.8 OPTIMASS 7000 / 7000F / 7400C

    The OPTIMASS 7000 / 7000F / 7400C is suitable for temperature classes T6.T1 according tothe following tables:

    OPTIMASS 7000 / 7000F - with or without heating jacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T55

    70 T5 T85

    90 T4 T105

    150 T3 T1 T165

    50

    70 T5 T85

    90 T4 T105150 T3 T1 T165

    6590 T4 T105

    130 T3 T1 T145

    2.7 OPTIMASS 6000F (high temperature)

    The OPTIMASS 6000F high temperature version, is suitable for temperature classes T6.T1according to the following tables:

    The cable supplied by KROHNE is designed for a continuous working temperature of up to85C. Alternative cabling must be a heat-resistant type with a minimum continuous workingtemperature of 85C.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    16/28

    16

    2.9 Painted options

    OPTIMASS 1000, 1000F, 1400C, 2000, 2000F, 2400C, 3400C, 6000, 6000F, 6400C, 7000,7000F,7400C are available with a paint finish to prevent corrosion.

    For painted meters, the maximum permissible ambient temperature Tamb is 40C and the

    maximum permissible medium temperature Tm is 110C (or lower as required by the

    temperature class).

    OPTIMASS 7400C with SS converter housing, with or without heating jacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T5570 T5 T85

    90 T4 T105

    130 T3 T1 T145

    5070 T5 T85

    90 T4 T1 T105

    60 60 T6 T1 T75

    OPTIMASS 7400C with aluminium converter housing, with or without heatingjacket / insulation

    Ambient Temp.Tamb C

    Max. mediumtemp. Tm C

    Temperature ClassMax. Surface

    Temp. C

    40

    40 T6 T55

    70 T5 T85

    90 T4 T105150 T3 T1 T165

    5090 T4 T105

    145 T3 T1 T160

    65 65 T6 T1 T80

    The cable supplied by KROHNE is designed for a continuous working temperature of up to

    85C. Alternative cabling must be a heat-resistant type with a minimum continuous workingtemperature of 85C.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    17/28

    17

    CONNECTION OF SEPARATED SYSTEMS OPTIMASS3

    3.1 General

    In the case of separate systems, the sensor and converter are connected using 5 pair lowcapacitance cable, with outer screen. Each cable pair carries an intrinsically safe circuit.

    The cable MUST NOT exceed the capacitance and inductance limits specified in section 3.2below.

    The requirements of IEC/EN 60079-14 should be adhered to when installing the flowmeter.

    3.2 Cable Parameters

    When selecting the connecting cable, note the following points:

    The maximum permitted total capacitance and inductance for the connecting cable is:

    CL = 90 nF

    LL = 36 H

    Cable supplied by Krohne meets the following specification:

    CL < 78 pF/m

    LL < 0.8 H/m

    The cable must have a temperature rating equal to, or better than, the maximum range oftemperatures present in the installation. When calculating the temperature range, youMUST give consideration to the temperature gradients on the flow sensors (see the notes insection 2).

    The cable must be capable of withstanding a test voltage of 1000V AC and have a minimuminsulation thickness of 0.2mm, as per IEC/EN60079-14 section 12.2.2.7

    3.3 Equipotential bondingThe MFC 400F mass flow converter or OPTIMASS X400C mass flow meter must be included inthe equipotential bonding of the installation using the equipotential bonding terminal on themass flow converter housing wall bracket or mass flow meter housing mounting stem respec-tively.

    In separated systems, a screened cable is used and is earthed at both the mass flow sensorand the mass flow converter ends. You MUST fit an equalisation cable with a minimum crosssection area of 4mm2, to the equipotential bonding terminals locted on the mass flow converterhousing bracket and the mass flow sensor electronics stem.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    18/28

    18

    MFC 400F mass flow sensor and converter junction box

    The supplied cable has twisted pairs

    Terminal block X1 are the signal circuits

    Terminal block X2 are the strain guage and temperature sensor circuits

    Terminal block X3 are the driver circuits

    Screening:

    Please see the illustrations above and refer to section 3.3.

    3.4 Terminal Connections

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    19/28

    19

    OPTIMASS4 ELECTRICAL CONNECTIONS

    4.1 General The MFC 400F mass flow converter (or OPTIMASS X400C mass flow meter) must be includ-

    ed in the equipotential bonding system of the installation. Do this by using the the equipo-tential bonding terminal on the mass flow converter housing wall bracket, or mass flowmeter electronics stem.

    The covers of the housing electronics compartment and the housing itself, are providedwith a "flameproof" thread. The thread is a tight fit because of explosion proofrequirements. Screw the cover on or off with care and never use excessive force.

    Keep the threads free of dirt and apply Teflon grease (eg. NONTRIBOS type Li EP2). Thegrease will help to prevent the threads from locking due to corrosion

    To open the covers, remove the hexagonal "retention" lock using a 2.5mm hex head tool.After closing the covers, refit the "retention lock".

    Electronics compartment:

    Allow the electronics to de-energize before opening the electronics compartment. For T6class meters wait for a minimum of 35 minutes and for T5 class meters, wait for aminimum of 10 minutes.

    Terminal compartment:

    The terminal compartment can be opened in hazardous areas, for a short period of time(eg. to check wiring configuration) with the power supply connected, where:

    a) the terminal compartment has an ignition protection type increased safety (standard) and

    b) the I/O circuits have an ignition protection type intrinsic safety and

    c) the cover for the power supply terminals (L,N) is closed (see illustration)

    Work on I/O terminals A-D can be carried out with the power supply connected, provided thatthe regulations regarding intrisically safe circuits are followed

    As soon as the work has been completed, the cover must be replaced and the retention lock re-fitted.

    N L D-DC-CB-BA+A-A

    1 Electrical Connections

    2 I/O Connections

    1 2

    Terminal Function, electrical data

    L, N

    L+, L-

    Connection for mains, always non-Ex i

    100..230 VAC, +10%/-15%, 22 VA

    12..24 V DC, +30%/-25%, 12 W

    24 VAC, +10%/-15%, 22VA

    24 VDC, +30%/-25%, 12W

    Um = 253 V

    A, A-,A+

    B, B-

    C, C-

    D, D-

    Connection for signal I/Os (PELV circuits), non-Ex I or ExI, are dependent on specific version of the MFC400 con-verter ordered.

    Consult the table with CG33 numbers below for details

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    20/28

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    21/28

    21

    The options separated with / are software selectable (can be changed by user)

    The options separated by or are hardware versions (must be ordered as such)

    All outputs are passive unless otherwise indicated

    HighC means High Current input/output, Namur means input/output to Namur recommen-dations

    Overview of possible combinations, defined by the CG33 number

    CharactersXYZ

    Name I/Ocircuits

    Terminals A, A- Terminals B, B- Terminals C, C- Terminals D, D-

    100 Basic I/O CO CO (a) over A+ SO/CI SO PO/SO

    488 to 4RR588 to 5RR688 to 6RR788 to 6RR

    888 to 8RRA88 to ARRB88 to BRRC88 to CRR

    Modular I/O orModular Carrier

    with 1 or 2 I/OModules

    Many combinations possible

    D88Fieldbus I/OProfibus PA

    n.c. n.c. PA PA

    D8A to DRR

    Fieldbus I/OProfibus PA withModule Carrierwith 1 or 2 I/OModules

    many combinations possible PA PA

    E88Fieldbus I/OFoundationFieldbus

    n.c n.c FF FF

    E8A to ERR

    Fieldbus I/OFoundationFieldbus withModule Carrierwith 1 or 2 I/OModules

    many combina-tions possible

    FF FF

    F00 Profibus DP I/O n.c DP(a) DP(a) DP(a)

    F80 to FROProfibus DP I/Owith 0 or 1 I/O

    many combina-tions

    DP(a) DP(a) DP(a)

    G00 to GRR RS485 Modbus

    Many combinations possible RS485 RS485

    H00 to HRRModbus with 1 or 2I/O modules

    shorts for in/output functions: CO= current output, PO=Pulse Output, SO= Status Output, CI= Control

    Input, PA=Profibus PA, FF=Foundation Fieldbus, DP=Profibus DP; RS458= RS485 Modbus. all in/outputs are passive unless otherwise noted as active (a) n.c. = not connected.

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    22/28

    22

    4.3 Ex i signal I/O connections

    Following intrinsically safe signal I/Os are available:

    The I/O circuits named Ex i I/O, Ex i Option are always in the Intrinsically safe (Ex ia) type ofprotection. The I/O circuits Fieldbus I/O Profibus PA and Fieldbus I/O Foundation Fieldbuscan be in the Intrinsically safety type of protection.

    A maximum of 4 intrinsically safe (Ex ia) in/outputs are possible. All intrinsically safe cir-cuits are galvanically insulated with respect to earth and each other. To avoid summation ofvoltages and currents, the wiring of these Ex ia circuits must be sufficiently separated, e.g.in line with the requirements of standard IEC/EN 60079-14, clause 12.2.

    The Ex ia signal in/outputs may only be connected to other Ex ia or ib certified device (e.g.intrinsically safe isolation amplifiers), even if such devices are installed in the non-haz-ardous area!

    Connection to a non-Ex i apparatus cancels the Ex ia properties of the flowmeter.

    Terminals L, N (or L+, L-) for mains connection are always non-intrinsically safe. To achievethe necessary spatial separation to IEC/EN 60079-11 between the non-Ex i and Ex i circuits,the mains terminals are provided with a semi-circular insulation cover with a "snap-in"lock. This cover MUST be closed before establishing the power supply to the converter.

    I/O PCB I/O functions

    Ex i I/O

    Current Output + HART communication

    Pulse / Status Output

    Ex ia IIC

    Ui =30V, Ii = 100 mA, Pi = 1,0 W

    Ci = 10nF, Li = negligibly low

    Current Output, active+ HART communication

    Ex ia IIC

    Uo = 21 V, Io = 90 mA, Po = 0,5 W

    linear characteristicCo = 90 nF, Lo =2,0 mHCo = 110 nF, Lo =0,5 mH

    Ex i OptionorEx i Option2

    Current input passive

    Current Output

    Pulse / Status Output / Control Input

    Ex ia IIC

    Ui =30V, Ii = 100 mA, Pi = 1,0 W

    Ci = 10nF, Li = negligibly low

    Current Output, active

    Ex ia IIC

    Uo = 21 V, Io = 90 mA, Po = 0,5 W

    linear characteristic

    Co = 90 nF, Lo = 2,0 mH

    Co = 110 nF, Lo = 0,5 mH

    Current input active

    Ex ia IIC

    Uo = 24.1 V, Io = 99 mA, Po = 0,6 W

    linear characteristic

    Co = 75 nF, Lo = 0.5 mH

    Fieldbus I/O

    Profibus-PA

    Foundation Fieldbus

    Ex ia IICUi = 24 V, Ii = 380 mA, Pi = 5,32 W

    Ci = 5 nF, Li = 10 H

    suitable for connection to an intrin-sically safe fieldbus in accordancewith the FISCO-model

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    23/28

    23

    Overview possible CG33 numbers with Ex ia in/outputs

    CharactersXYZ

    Name I/Ocircuits

    Terminals A, A- Terminals B, B- Terminals C, C- Terminals D, D-

    200 Ex i I/O n.c. n.c. CO (a) PO/SO

    300 n.c. n.c. CO PO/SO

    210

    Ex i I/O

    with

    Ex i Option

    CO (a) PO/SO/CI CO (a) PO/SO

    220 CO PO/SO/CI CO (a) PO/SO

    310 CO (a) PO/SO/CI CO PO/SO

    320 CO PO/SO/CI CO PO/SO

    D00Fieldbus I/O

    Profibus PAn.c. n.c PA PA

    D10

    Fieldbus I/O

    Profibus PA

    with

    Ex i Option

    CO (a) PO/SO/CI PA PA

    D20 CO PO/SO/CI PA PA

    E00

    Fieldbus I/O

    FoundationFieldbus

    n.c. n.c FF FF

    E10

    Fieldbus I/O

    Foundation

    FieldbuswithEx i Option

    CO (a) PO/SO/CI FF FF

    Abbreviations for in/output functions: CO= current output, PO=Pulse Output, SO= Status Output, CI=Control Input, PA=Profibus PA, FF=Foundation Fieldbus, DP=Profibus DP

    All in/outputs are passive unless otherwise noted as active (a) n.c. = not connected

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    24/28

    24

    OPTIMASS5 SERVICE AND MAINTENANCE

    5.1 Maintenance

    The OPTIMASS flowmeters are maintenance free with respect to the flowmetering properties.Within the scope of periodic inspections required for electrical equipment installed in haz-ardous areas it is recommended to check the flameproof converter housing and covers forsigns of damage or corrosion.

    5.2 Replacement of mains fuseOpen the window cover. Press the two metal clips on each side of the display and pull the dis-play unit forward. Move the display-unit sideward, out of the way. Loosen the two crossheadscrews holding the electronic unit is place. Slide the electronic unit forward, with care. Whenthe unit is almost completely removed from the housing, disconnect the long rectangular (10-pole) blue connector at the back-end of the unit. This connector is for the flow sensor circuits.Remove the unit from the housing.

    The mains fuse is situated in a fuse holder at the back-end of the electronic unit. The specifica-tion must be as follows:

    5.3 Returning the device for service or repair

    This device has been carefully manufactured and tested. If installed and operated in accor-dance with these operating instructions, it will rarely present any problems. Should you needto return a device for inspection or repair, please pay strict attention to the following points:

    Due to statutory regulations on environmental protection and safeguarding the health andsafety of our personnel, KROHNE may only handle, test and repair returned devices that havebeen in contact with products without risk to personnel and environment.

    This means that KROHNE can only service this device if it is accompanied by the following cer-tificate confirming that the device is safe to handle.

    If the device has been operated with toxic, caustic, flammable or water polluting liquids, youare kindly requested:

    To check and ensure, if necessary by rinsing or neutralizing, that all cavities in the device arefree from dangerous substances.

    To enclose a certificate with the device confirming that it is safe to handle and stating the prod-uct used.

    We cannot service your device unless accompanied by a certificate.

    The specimen shown in appendix 1 can be photocoppied and used and it is also available on theKROHNE website as a word file. Simply download and use the tabulator key to go from one fill-out field to the next. Please attach the form to the returned device

    Fuse type: 5 x 20 mm (H) according to IEC 60127-2/V

    Power Supply: Time Lag: KROHNE Part Number:

    12-24 VDC 250V / 2A 5060200000

    24 VAC/DC 250V / 2A 5060200000

    100-230 VAC 250V / 0.8A 5080850000

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    25/28

    25

    Appendix 1 Declaration of Cleanliness Certificate

    Company: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Department: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tel. No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fax No.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    The enclosed device

    Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    KROHNE Order No. or Series No.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    has been operated with the following liquid: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Because this liquid is water-hazardous toxic caustic flammable

    we have checked that all cavities in the instrument are free from such substances /

    flushed out and neutralized all cavities in the device

    We confirm that there is no risk to humans or environment through any residual liquid contained in this

    device.

    Date: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Signature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Company stamp:

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    26/28

    26

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    27/28

    27

  • 8/10/2019 Ma Optimass Mfc400 Haz_areas_en

    28/28

    Australia

    KROHNE Australia Pty Ltd

    Quantum Business Park10/287 Victoria Rd

    Rydalmere NSW 2116

    TEL.: +61 2 8846 1700FAX: +61 2 8846 1755

    e-mail: [email protected]

    Austria

    KROHNEAustria Ges.m.b.H.

    Modecenterstrae 14

    A-1030 Wien

    TEL.: +43(0)1/203 45 32FAX: +43(0)1/203 47 78

    e-mail: [email protected]

    Belgium

    KROHNEBelgium N.V.

    Brusselstraat 320

    B-1702 Groot Bijgaarden

    TEL.: +32(0)2-4 66 00 10FAX: +32(0)2-4 66 08 00

    e-mail: [email protected]

    BrazilKROHNEConaut

    Controles Automaticos Ltda.

    Estrada Louis Pasteur, 230 C.P. 56

    06835 - 080 EMBU - SPTEL.: +55(0)11-4785-2700

    FAX: +55(0)11-4785-2768

    e-mail: [email protected]

    China

    KROHNEMeasurement Instruments

    (Shanghai) Co. Ltd.9th Floor, Xujiahui International Building

    1033 Zhaojiabang Road

    Shanghai 200030

    P. R.ChinaTEL.: +86 21 6487 9611

    FAX: +86 21 6438 7110

    e-mail: [email protected]

    CIS

    Kanex KROHNE Engineering AG

    Business-Centre Planeta, Office 403

    Marxistskaja-Street 3109147 Moscow/Russia

    TEL.: +7(0)095-9117 165

    FAX: +7(0)095-9117 231e-mail: [email protected]

    Czech Republic

    KROHNECZ, spol.s r.o.

    Sobick 15663800 Brno

    TEL.: +420 545 532 111

    FAX: +420 545 220 093

    e-mail: [email protected]

    Algeria

    Argentina

    Belarus

    CameroonCanada

    Chile

    Colombia

    CroatiaDenmark

    Ecuador

    Egypt

    FinlandGabon

    Ghana

    Greece

    Hong KongHungary

    Indonesia

    Ivory Coast

    IranIreland

    Israel

    Japan

    Jordan

    KuwaitLibya

    Lithuania

    Malaysia

    MoroccoMauritius

    Mexico

    New Zealand

    PeruPoland

    Portugal

    Romania

    Saudi ArabiaSenegal

    Slovakia

    Slovenia

    SwedenTaiwan

    Thailand

    Turkey

    TunisiaVenezuela

    Yugoslavia

    France

    KROHNES.A.S.

    Les OrsBP 98

    F-26103 ROMANS Cedex

    TEL.: +33(0)4-75 05 44 00

    FAX: +33(0)4-75 05 00 48e-mail: [email protected]

    Germany

    KROHNEMesstechnik

    GmbH & Co. KGLudwig-Krohne-Str.

    D-47058 Duisburg

    TEL.: +49(0)203-301-0

    FAX: +49(0)203-301-10 389e-mail: [email protected]

    India

    KROHNEMarshall Ltd.

    A-34/35,M.I.D.C.

    Industrial Area,H-Block,Pimpri Poona 411018

    TEL.: +91(0)202-7442020

    FAX: +91(0)202-7442020

    e-mail: [email protected]

    Iran

    KROHNE Liaison Office

    North Sohrevardi Ave.

    26,Sarmad St.,Apt.#9

    Tehran 15539TEL.: ++98-21-874-5973

    FAX: ++98-21-850-1268

    e-mail: [email protected]

    Italy

    KROHNEItalia Srl.

    Via V.Monti 75

    I-20145 Milano

    TEL.: +39(0)2-4 30 06 61FAX: +39(0)2-43 00 66 66

    e-mail:[email protected]

    Korea

    KROHNE Korea

    Room 508 Miwon Bldg43 Yoido-Dong

    Youngdeungpo-Ku

    Seoul, Korea

    TEL.: 00-82-2-780-1743FAX: 00-82-2-780-1749

    e-mail: [email protected]

    Netherlands

    KROHNEAltometer

    Kerkeplaat 12NL-3313 LC Dordrecht

    TEL.: +31(0)78-6306300

    FAX: +31(0)78-6306390

    e-mail: [email protected]

    Netherlands

    KROHNENederland B.V.

    Kerkeplaat 14

    NL-3313 LC Dordrecht

    TEL.: +31(0)78-6306200FAX: +31(0)78-6306405

    Service Direkt:+31(0)78-6306222

    e-mail: [email protected]

    Norway

    KROHNENorway A.S.

    Ekholtveien 114NO-1526 Moss

    P.O.Box 2178,NO-1521 Moss

    TEL.: +47(0)69-264860

    FAX: +47(0)69-267333e-mail: [email protected]

    Internet: www.krohne.no

    Singapore

    Tokyo Keiso - KROHNE Singapore Pte. Ltd.

    14, International Business Park,

    Jurong EastChiyoda Building #01-01/02

    Singapore 609922

    Singapore

    TEL.: ++65-65-67-4548FAX: ++65-65-67-9874

    South Africa

    KROHNEPty.Ltd.163 New Road

    Halfway House Ext. 13

    Midrand

    TEL.: +27(0)11-315-2685FAX: +27(0)11-805-0531

    e-mail: [email protected]

    Spain

    I.I.KROHNE Iberia,S.r.L.

    Poligono Industrial Nilo

    Calle Brasil,n. 5

    E-28806 Alcal de Henares -MadridTEL.: +34(0)91-8 83 21 52

    FAX: +34(0)91-8 83 48 54

    e-mail: [email protected]

    Switzerland

    KROHNEAG

    Uferstr.90CH-4019 Basel

    TEL.: +41(0)61-638 30 30

    FAX: +41(0)61-638 30 40

    e-mail: [email protected]

    United Kingdom

    KROHNELtd.

    Rutherford DrivePark Farm Industrial EstateWellingborough,

    Northants NN8 6AE, UKTEL.: +44(0)19 33-408 500

    FAX: +44(0)19 33-408 501

    e-mail: [email protected]

    USA

    KROHNEInc.

    7 Dearborn RoadPeabody, MA 01960

    TEL.: +1-978 535-6060

    FAX: +1-978 535-1720

    e-mail: [email protected]

    Other Representatives

    Other Countries

    KROHNEMesstechnik

    GmbH & Co. KGLudwig-Krohne-Str.

    D-47058 Duisburg

    TEL.:+49(0)203-301-0

    FAX: +49(0)203-301-389e-mail: [email protected]

    Subject to change without notice

    KROHNE08/201

    0

    4003491801

    Krohnereservestherighttomakechangeswithoutpriornotice