14
Page 1 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us Project: Type: Qty: Date: Customer: M36 LED Direct Custom colors are available, Please consult factory Order Code: - - - - - - Emergency Options Driver EC 17 Emergency Circuit Wiring DML 9,10 eldoLED SOLO- drive 0-10V (Logarithmic) DMD 9,10 eldoLED DALI (Logarithmic) DCE 9,10 Lutron Eco- System DC3 9,10 Lutron 3-Wire DC2 9,10,11 Lutron 2-Wire V90 18 Lit Inverted 90° Corner IT90 18 Lit “T” section IX90 18 Lit “X” section IL90 18 Lit Horizontal 90° Corner 17 See page 8 for full details and restrictions 18 See page 10 for full details and restrictions 9 See page 7 for full details 10 Not available for 1’ length Configuration Options - - - Individual fixtures, Runs and Configurations are supplied in nominal lengths to ensure full, even, illumination. See pages 2 thru 6 for additional details. DL 13 Damp Location Rated FS 13 In-line Fuse SS 13 Separate Switching Fixture Options 13 See page 8 for full details and restrictions LU 4,5 Light Up Lens DR 4,5 Drop Lens VC 6 Specular Louver 11 120V only DM 9,10 eldoLED SOLOdrive 0-10V (Linear) DIM 9 0-10V (Linear) Sensor Options xE 14,15 Enlighted xP1 14,15 Philips Daylight xP2 14,15 Philips Occ/Vac xP3 14,15 Philips Occ/Vac/ Daylight xS1 14,16 Sensor Switch Daylight xS2 14,16 Sensor Switch Occ/Vac xS3 14,16 Sensor Switch Occ/Vac/ Daylight 14 Minimum fixture length 2’. See page 9 for full details and restrictions. 15 For use with SR driver only 16 For use with DIM driver only 12 For use with E and P sensors only 4 Not available with sensors 5 Individual fixtures only. For Runs and Configurations, please consult factory. See page 8 for details. 6 Not available with IL90, V90, or IX90 Configurations. Replace “x” with quantity - - - VM 6 Matte Silver Louver VB 6 Matte Black Louver VW 6 Matte White Louver xSN nLight Enabled (consult factory) EMR Remote Micro Inverter (consult factory) EM Internal EM Battery Pack (consult factory) DC5 Lutron 5-Series (consult factory) Series L36 M36 LED Direct Light Engine 1B45 1,2,3 908lm/11.8W per foot 1B40 1,2,3 821lm/10.5W per foot 1B35 1 722lm/9.2W per foot 1B30 1,2 617lm/7.7W per foot CCT 30 3000K 35 3500K 40 4000K Shielding LW LED Optimized white lens MI Clear Lens w/microprism NB LMO Symmetric A2 LMO Asymmetric 20° Wall Washer BW LMO Batwing Mounting FF 8 Surface Mount (w/ Flex Whip) C Cable S Swivel Stem RS Rigid Stem W 7 Wall Mount Nominal Fixture Length 01 * 1 ft. 02 2 ft. 04 4 ft. 03 3 ft. 05 5 ft. 06 6 ft. 08 8 ft. 07 7 ft. XX Runs (over 12’) & Configurations, round up to the nearest foot and replace the “xx” with the # (i.e. 13=13’ nominal) Finish WH White BK Black SV Silver SP Specify Premium Color Voltage 120 120 Volt 277 277 Volt L36 LED WARRANTY 5 YEAR ARRA Compliant ADA Compliant L36 27 2700K F2 8 Surface Mount (for 2x4J-Box) F4 8 Surface Mount (w/4x4 J-Box cover) 7 Consult factory for lengths under 2’ 8 Over 8’ supplied with 2 or more housings that are joined in the field. 09 9 ft. 11 11 ft. 10 10 ft. 12 12 ft. UNV 120 thru 277 50/60hz capable A5 LMO Asymmetric 5° Wall Grazer 1 Values calculated from a 4’ fixture @4000K using LW Shielding and DIM driver. For additional information please see page 2. * 1’ fixture only available with 1B35 light engine SR 9,10,12 Philips Xitanium SR DALI 1B25 1,2 553lm/6.8W per foot 1B20 1,2 417lm/5.1W per foot 2 Available starting at 2’ and up. 3 Not available with Lutron. BL Semi-Matte Black 347 347 Volt (consult factory)

M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Embed Size (px)

Citation preview

Page 1: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 1 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Project:

Type: Qty:

Date: Customer:

M36LED Direct

Custom colors are available, Please consult factory

Order Code: - - - - - -

Emergency Options

Driver

EC17 Emergency Circuit Wiring

DML9,10

eldoLED SOLO-drive 0-10V (Logarithmic)

DMD9,10 eldoLED DALI (Logarithmic)

DCE9,10 Lutron Eco-System

DC39,10 Lutron 3-Wire

DC29,10,11 Lutron 2-Wire

V9018 Lit Inverted 90° Corner

IT9018 Lit “T” section

IX9018 Lit “X” section

IL9018 Lit Horizontal 90° Corner

17See page 8 for full details and restrictions

18See page 10 for full details and restrictions

9See page 7 for full details10Not available for 1’ length

Configuration Options

- - -

Individual fixtures, Runs and Configurations are supplied in nominal lengths to ensure full, even, illumination. See pages 2 thru 6 for additional details.

DL13 Damp Location Rated

FS13 In-line Fuse

SS13 Separate Switching

Fixture Options

13See page 8 for full details and restrictions

LU4,5 Light Up Lens

DR4,5 Drop Lens

VC6 Specular Louver

11120V only

DM9,10 eldoLED SOLOdrive 0-10V (Linear)

DIM9 0-10V (Linear)

Sensor Options

xE14,15 Enlighted

xP114,15 Philips Daylight

xP214,15 Philips Occ/Vac

xP314,15 Philips Occ/Vac/Daylight

xS114,16 Sensor Switch Daylight

xS214,16 Sensor Switch Occ/Vac

xS314,16 Sensor Switch Occ/Vac/Daylight

14 Minimum fixture length 2’. See page 9 for full details and restrictions.

15 For use with SR driver only16 For use with DIM driver only

12For use with E and P sensors only

4Not available with sensors

5I ndividual fixtures only. For Runs and Configurations, please consult factory. See page 8 for details.

6 Not available with IL90, V90, or IX90 Configurations.

Replace “x” with quantity

- - -

VM6 Matte Silver Louver

VB6 Matte Black Louver

VW6 Matte White Louver

xSN nLight Enabled (consult factory)

EMR Remote Micro Inverter (consult factory)

EM Internal EM Battery Pack (consult factory)

DC5 Lutron 5-Series (consult factory)

Series L36 M36 LED Direct

Light Engine 1B451,2,3 908lm/11.8W per foot

1B401,2,3 821lm/10.5W per foot

1B351 722lm/9.2W per foot

1B301,2 617lm/7.7W per foot

CCT 30 3000K

35 3500K

40 4000K

Shielding LW LED Optimized white lens

MI Clear Lensw/microprism

NB LMO Symmetric

A2 LMO Asymmetric 20° Wall Washer

BW LMO Batwing

Mounting FF8 Surface Mount (w/Flex Whip)

C Cable

S Swivel Stem

RS Rigid Stem

W7 Wall Mount

Nominal Fixture Length

01* 1 ft.

02 2 ft.

04 4 ft.

03 3 ft.

05 5 ft.

06 6 ft.

08 8 ft.

07 7 ft.

XX Runs (over 12’) & Configurations, round up to the nearest foot and replace the “xx” with the # (i.e. 13=13’ nominal)

Finish WH White

BK Black

SV Silver

SP Specify Premium Color

Voltage 120120 Volt

277277 Volt

L36

LED WARRANTY

5YEAR

ARRA Compliant

ADA Compliant

L36

27 2700K

F28 Surface Mount (for 2x4J-Box)

F48 Surface Mount (w/4x4 J-Box cover)

7Consult factory for lengths under 2’

8 Over 8’ supplied with 2 or more housings that are joined in the field.

09 9 ft.

11 11 ft.

10 10 ft.

12 12 ft.

UNV120 thru 277 50/60hz capable

A5 LMO Asymmetric 5° Wall Grazer

1 Values calculated from a 4’ fixture @4000K using LW Shielding and DIM driver. For additional information please see page 2.

* 1’ fixture only available with 1B35 light engine

SR9,10,12 Philips Xitanium SR DALI

1B251,2 553lm/6.8W per foot

1B201,2 417lm/5.1W per foot 2 Available starting at 2’ and up.

3 Not available with Lutron.

BL Semi-Matte Black

347347 Volt (consult factory)

Page 2: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 2 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Construction:

Housing - Continuous, low copper 6063-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 12’) or Runs.

Geartray - Low copper 6063-T6 extruded aluminum profile.

Shielding - Extruded, impact resistant acrylic lens:- LED optimized white lens (LW)- Clear lens with microprism inlay (MI)- “LMO” symmetric lens (NB)- “LMO” Asymmetric 5° wall grazer (A5)- “LMO” Asymmetric 20° wall washer (A2)- “LMO” Batwing (BW)- LED optimized Light Up Lens (LU)- LED optimized Drop Lens (DL)- Louvers: (VC) Specular, (VM) Matte Silver, (VB) Matte Black, (VW) Matte White- “LMO” refers to the Selux proprietary LED opti-cal system - Light Modulation Optics.

Mounting(s) - 1/16” Aircraft Cable, Ø1/2” Swivel or Rigid Steel Stem, Wall Bracket, Surface mounting (see pages 3 thru 6 for details).** Cable, Stem and Wall mountings may not be symmetrical for Runs and Configurations due to the use of modular housing lengths. If sym-metrical suspensions are required please consult the factory.

Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs and Con-figurations are available in approximately 1 1/2” increments starting at the nominal 12’ fixture length. ** Individual luminaires are not joinable in the field.

Exact length luminaires - Individual lumi-naires, Runs, and Configuration are available in exact lengths to meet your project needs. Please consult factory with your requirements. ** Lens luminance may soften at the very ends of the straight sections for exact length lumi-naires.

M36 Joiner(s) - Runs and Configurations are supplied in multiple housing that are joined together in the field using the supplied M36 Joiner System. This allows ease of installation and ensures a uniform appearance (see page 8 for detail).

Weight - 1.8 lb per foot

Electrical/Performance:

LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at 25,000 hours and 93% at 60,000 hours @ 25ºC per TM-21 reports. Reported L70 greater than 60,000 hours.

Delivered Lumens - Due to LED manufacturer’s tolerances the listed output has a ±5% toler-ance. For outputs based on different shielding or CCT please see photometry section at the end.

CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse.

CRI - Min. 90.

All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC > 0.90. For more detailed information on the available drivers please see page 7.

Sensors - Selux offers a variety of integral sensor options. For details and specifications, please refer to page 9.

Thermal Performance:

Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of 35° C (95° F) for all drivers.

Luminaires are suitable for minimum ambient temperatures of:-40ºC (-40ºF) for DIM, DM, DML, and DMD drivers.-20ºC (-4ºF) for SR drivers.0ºC (32ºF) for DC2, DC3, and DCE drivers.

Luminaire Finish:

Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI.

All products undergo a five stage intensive pretreatment process where product is thor-oughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention.

Standard interior colors are White (WH), Black (BK), Semi-Matte Black (BL), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.

Warranty:

5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the M36 series LED lumi-naire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see “Selux Terms and Condition of Sale.”

Certifications and Compliance: NRTL - For Dry and Damp location (I.E. cULus; cCSAus)ADA CompliantARRA CompliantRoHS Compliant

M36LED Direct

1 5/16” (34mm)

1 7/16” (37mm)

LOUVERDIFFUSER1/4” (6mm)

1 7/16” (37mm)

Light Up Lens Drop Lens LMO Lens LW lens shown for reference

Louver

2 13/16” (72mm)

Page 3: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 3 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Cable Mounting (C)

M36LED Direct

Outlet box for feed only (by others)

L36 Cable (C) Suspension Detail (Feed location(s) only)

L36 Cable (C) Suspension Detail (Non-Feed location(s) only)

Cross bar with 1/4-20 rod and ground screw

1/4” x 5” diameter canopy (white)

2x White cable stay

Cord strain relief bushing

Chrome gripper

1/4”- 20 Threaded Rod (supplied & installed in the field by others)

1. Ø 1/16” Aircraft Cable with chrome gripper for easy adjustment (48” max. from ceiling to luminaire).

2x Outlet box screws (by others)

1/4-20 Slip ring coupler

Feed cord (white)

1/16” Aircraft cable

Luminaire

1/4-20 Slip ring coupler

1/16” Aircraft cable

Chrome gripper

Luminaire

1/4” x 2” diameter Canopy (white)

Cable Mounting (C) - Dimensions

Nominal Length

“A” Housing Length

* “B” (Ref.) End Suspensions

“C” Mid. Suspension

“D” Feed Location

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

01 (1 ft.) 1' - 5/16" 313 0' - 2 1/8" 54 0'- 8 1/8" 206 0' - 1 1/8" 29

02 (2 ft.) 2' - 1/4" 616 0' - 2 1/8" 54 1'- 8 1/16" 509 0' - 1 1/8" 29

03 (3 ft.) 3' - 5/16" 923 0' - 3 1/8" 79 2'- 6 1/16" 764 0' - 2 1/8" 54

04 (4 ft.) 4' - 1/4" 1225 0' - 3 1/8" 79 3'- 6" 1067 0' - 2 1/8" 54

05 (5 ft.) 4' - 10 11/16" 1491 0' - 3 1/8" 79 4'- 4 7/16" 1332 0' - 2 1/8" 54

06 (6 ft.) 5' - 10 5/8" 1794 0' - 3 1/8" 79 5'- 4 7/16" 1636 0' - 2 1/8" 54

07 (7 ft.) 7' - 1/4" 2140 0' - 3 1/8" 79 6'- 6" 1981 0' - 2 1/8" 54

08 (8 ft.) 8' - 1/4" 2444 0' - 3 1/8" 79 7'- 6" 2286 0' - 2 1/8" 54

09 (9 ft.) 8' - 10 5/8" 2709 0' - 3 1/8" 79 8'- 4 7/16" 2551 0' - 2 1/8" 54

10 (10 ft.) 9' - 10 5/8" 3013 0' - 3 1/8" 79 9'- 4 3/8" 2854 0' - 2 1/8" 54

11 (11 ft.) 11' - 3/16" 3358 0' - 3 1/8" 79 10 - 6" 3200 0' - 2 1/8" 54

12 (12 ft.) 12' - 3/16" 3662 0' - 3 1/8" 79 11'- 5 15/16" 3503 0' - 2 1/8" 54

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance.

Cable Mounting (C)

Min. 5/8” to Max. 3/4”

Page 4: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 4 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Stem Mounting (S & RS)

Outlet box (supplied & installed by others)

L36 Swivel Stem (S) Suspension Detail (feed wires through stem supplied by Selux)

L36 Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by Selux)

Hemispherical assembly

1/4 IP Swivel crossbar with ground screw

3/4” x 5” diameter canopy (white)

1. Ø 1/2” Swivel Stem provides 45° swivel and can be cut in field (48” max. from ceiling to luminaire).

2. Ø 1/2” Rigid Stem is fixed and is not able to be cut/adjusted in field (48” max. from ceiling to luminaire).

Cotter pin

1/4 IP steel swivel stem (white)

3/8 Male x 1/4 Male hex bushing

Luminaire Luminaire

Outlet box (supplied & installed by others)

1/4 IP Crossbar with ground screw

1/4 IP Hex nut

1/4” x 5” diameter canopy (white)

Canopy securing screw (white)

1/4 IP Steel rigid stem (white)

3/8 Male x 1/4 Male hex bushing

Swivel (S) & Rigid Stem (RS) Mountings - Dimensions

Nominal Length

“A” Housing Length

* “B” (Ref.) End Suspensions

“C” Mid. Suspension

“D” Feed Location

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

01 (1 ft.) 1'- 5/16" 313 0' - 2 1/8" 54 0'- 8 1/8" 206 0' - 2 1/8" 54

02 (2 ft.) 2'- 1/4" 616 0' - 2 1/8" 54 1'- 8 1/16" 509 0' - 2 1/8" 54

03 (3 ft.) 3'- 5/16" 923 0' - 3 1/8" 79 2'- 6 1/16" 764 0' - 3 1/8" 79

04 (4 ft.) 4'- 1/4" 1225 0' - 3 1/8" 79 3'- 6" 1067 0' - 3 1/8" 79

05 (5 ft.) 4'- 10 11/16" 1491 0' - 3 1/8" 79 4'- 4 7/16" 1332 0' - 3 1/8" 79

06 (6 ft.) 5'- 10 5/8" 1794 0' - 3 1/8" 79 5'- 4 7/16" 1636 0' - 3 1/8" 79

07 (7 ft.) 7’- 1/4" 2140 0' - 3 1/8" 79 6'- 6" 1981 0' - 3 1/8" 79

08 (8 ft.) 8'- 1/4" 2444 0' - 3 1/8" 79 7'- 6" 2286 0' - 3 1/8" 79

09 (9 ft.) 8'- 10 5/8" 2709 0' - 3 1/8" 79 8'- 4 7/16" 2551 0' - 3 1/8" 79

10 (10 ft.) 9'- 10 5/8" 3013 0' - 3 1/8" 79 9'- 4 3/8" 2854 0' - 3 1/8" 79

11 (11 ft.) 11'- 3/16" 3358 0' - 3 1/8" 79 10 - 6" 3200 0' - 3 1/8" 79

12 (12 ft.) 12'-3/16" 3662 0' - 3 1/8" 79 11'- 5 15/16" 3503 0' - 3 1/8" 79

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance.

Stem Mounting (S & RS)

Page 5: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 5 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Wall Mounting (W)

1. Aluminum wall bracket (by Selux)2. 2” x 4” J-Box at feed location (supplied and installed by others).3. 1/4-20 Threaded rod, 1/4-20 lock washer and 1/4-20 nut required to

anchor the wall bracket. Mounting hardware supplied and installed to code by others.

Wall Mount (W) (Covers a 2x4 J-Box only)

Wall (W) Mount - Dimensions

Nominal Length

“A” Housing Length

* “B” (Ref.) End Suspensions

“C” Mid. Suspension

“D” Feed Location

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

01 (1 ft.) 1' - 5/16" 313 0' - 6 3/16" 157 N/A 0' - 6 3/16" 157

02 (2 ft.) 2' - 1/4" 616 0' - 3 1/8" 79 1' - 6 1/16" 458 0' - 3 1/8" 79

03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 2' - 1/8" 612 0' - 6 1/8" 156

04 (4 ft.) 4' - 1/4" 1225 0' - 6 1/8" 156 3' - 0" 914 0' - 6 1/8" 156

05 (5 ft.) 4' - 10 11/16" 1491 0' - 6 1/8" 156 3' - 10 7/16" 1180 0' - 6 1/8" 156

06 (6 ft.) 5' - 10 5/8" 1794 0' - 6 1/8" 156 4' - 10 7/16" 1484 0' - 6 1/8" 156

07 (7 ft.) 7' - 1/4" 2140 0' - 6 1/8" 156 6' - 0" 1829 0' - 6 1/8" 156

08 (8 ft.) 8' - 1/4" 2444 0' - 6 1/8" 156 7' - 0" 2133 0' - 6 1/8" 156

09 (9 ft.) 8' - 10 5/8" 2709 0' - 6 1/8" 156 7' - 10 7/16" 2398 0' - 6 1/8" 156

10 (10 ft.) 9' - 10 5/8" 3013 0' - 6 1/8" 156 8' - 10 3/8" 2702 0' - 6 1/8" 156

11 (11 ft.) 11' - 3/16" 3358 0' - 6 1/8" 156 9' - 11 15/16" 3047 0' - 6 1/8" 156

12 (12 ft.) 12' - 3/16" 3662 0' - 6 1/8" 156 10' - 11 7/8" 3350 0' - 6 1/8" 156

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance.

2 3/4” (70mm)

4” (102mm)

1” (25mm)

2 7/16” (62mm)

Page 6: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 6 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Surface Mounting (FF, F2 & F4) - 1’ to 8’

1. 6’ Flex Whip2. Ø 5/16” Mounting hole drilled at the factory(mounting hardware to code by others).3. 2”x 4” J-Box at feed location (supplied and installed by others).4. 2”x 4” J-Box cover (by Selux).5. 4”x 4” J-Box at feed location (supplied and installed by others).6. 4”x 4” J-Box cover (by Selux).

Surface Mount (FF)* (with Flex Whip)

Surface Mounting (FF, F2 & F4) - Over 9’

Surface Mount (F2) (with 2x4 J-Box cover)

Surface Mount (F4) (with 4x4 J-Box cover)

* Please note: Fixture does not cover a J-Box.

Surface Mount (FF, F2, & F4) - Dimensions

Nominal Length

“A” Housing Length

* “B” (Ref.) End Suspensions

* “B1” End Suspensions

“C” Mid. Suspension

“C1” Mid. Suspension

“C2” Mid. Suspension

“D” Feed Location

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

01 (1 ft.) 1' - 5/16" 313 0' - 1 5/8" 41 N/A 0' - 9 1/8" 231 N/A N/A 0' - 4 1/8" 105

02 (2 ft.) 2' - 1/4" 616 0' - 1 5/8" 41 N/A 1' - 9" 534 N/A N/A 0' - 4 1/8" 105

03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 N/A 2' - 1/8" 612 N/A N/A 0' - 2 1/8" 54

04 (4 ft.) 4' - 1/4" 1225 0' - 6 1/8" 156 N/A 3’ 914 N/A N/A 0' - 2 1/8" 54

05 (5 ft.) 4' - 10 11/16" 1491 0' - 6 1/8" 156 N/A 3' - 10 7/16" 1180 N/A N/A 0' - 2 1/8" 54

06 (6 ft.) 5' - 10 5/8" 1794 0' - 6 1/8" 156 N/A 3' 914 1' - 10 3/8" 569 N/A 0' - 2 1/8" 54

07 (7 ft.) 7' - 1/4" 2140 0' - 6 1/8" 156 N/A 3' 914 3' 914 N/A 0' - 2 1/8" 54

08 (8 ft.) 8' - 1/4" 2444 0' - 6 1/8" 156 N/A 3' 914 4' 1219 N/A 0' - 2 1/8" 54

09 (9 ft.) 8' - 10 5/8" 2709 0' - 6 1/8" 156 6” 153 3' - 10 7/16" 1180 N/A 3' 914 0' - 2 1/8" 54

10 (10 ft.) 9' - 10 5/8" 3013 0' - 6 1/8" 156 6” 153 3' 914 1' - 10 3/8" 569 3' 914 0' - 2 1/8" 54

11 (11 ft.) 11' - 3/16" 3359 0' - 6 1/8" 156 6” 153 3' 914 3' 914 3' 914 0' - 2 1/8" 54

12 (12 ft.) 12' - 3/16" 3662 0' - 6 1/8" 156 6” 153 3' 914 4' 1219 3' 914 0' - 2 1/8" 54

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance.

Page 7: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 7 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Driver Quantity

1 ft. 2 ft. 3 ft. 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. RUN

DIM, DM, DML, DMD, and SR drivers 1 1 1 1 1 1 2 2 2 2 3 3 Approximately 1 driver per 4 ft.

DC2, DC3, & DCE drivers N/A 1 1 1 2 2 2 3 3 3 3 3 Consult Factory

Drivers:

0-10V linear dimming (DIM)Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%. (Due to size con-straints, 1’ luminaires are supplied with a driver from a different manufac-turer than 2’ and above luminaires. For details, please consult factory).

eldoLED SOLOdrive 0-10V linear dimming (DM)Luminaires supplied with SOLOdrive 0-10V dimming driver for linear dim-ming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.

eldoLED SOLOdrive 0-10V logarithmic dimming (DML)Luminaires supplied with SOLOdrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.

eldoLED SOLOdrive DALI dimming (DMD)Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.

* For control recommendations for eldoLED drivers, please consult eldoLED.

LUTRON 2-wire dimming (DC2)Luminaires supplied with Hi-Lume 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.

LUTRON 3-wire dimming (DC3)Luminaires supplied with Hi-Lume 3-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.

LUTRON Ecosystem dimming (DCE)Luminaires supplied with Hi-Lume EcoSystem (4 wire, digital link) dim-ming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.

* For control recommendations and system layout for Lutron drivers, please contact Lutron.

Philips Xitanium Sensor Ready DALI dimming (SR)Luminaires supplied with Xitanium SR dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 5%. For use with E and P sensors only.

*For inrush and control current, please refer to the driver manufacturers’ spec sheets.

Wiring Diagrams Sensor Wiring Diagrams

ENLIGHTEDOR PHILIPSSENSOR

ELDO 0-10V

SENSORSWITCH

PHILIPS XR

SR (+)SR (-)

(+)(-) 0-10V AUX (+)

AUX (-)

standard0-10V linear (DIM) 0-10V linear eldoLED SOLOdrive (DM)0-10V logarithmic eldoLED SOLOdrive (DML)DALI eldoLED SOLOdrive (DMD)Philips SR DALI (SR)

DIM, DM, DML, DMD & SR

DALIDALI

Page 8: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 8 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse).

Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing.

*For Damp Location with sensors, please consult factory.

Separate Switching (SS) - Luminaires available with separately switched 4’ (nominal) sections starting at 7’ and up. Luminaire is in-tended to be wired to the same panel/breaker (not intended for Emer-gency use).

- To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order.

*If the project requires different separate switching than outlined above please consult the factory.

*For Separate Switching with sensors, please consult factory.

Emergency Circuit (EC) - Luminaires with EC option compliant to UL 924 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use.

- For 1’ to 6’ nominal luminaires, the entire fixture is wired for operation on emergency circuit.

- For 7’ and up nominal luminaires, the first 4’ nominal length is wired for operation by a separate EM circuit by default to meet the required “Life Safety Code” (NFPA 101).

*If a different configuration is needed please consult the factory.

*For EC with sensors, please consult factory.

90° Elbow on top of the housing (7/8" feed hole)

3/8" flexible metal conduit (6' long)

6" leads

Straight fitting

Flex Whip - standard for FF mounting Joiner System - standard for Runs and Configurations

Fixture extrusion

Joiner extrusion

Recommended #2 Phillips drive

Fixture extrusion

Additional view

Light Up or Drop Lens Detail

Light Up or Drop Lens

Housing

Light Up Lens 6mm Drop Lens 37mm

Page 9: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 9 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Lens

3” (76mm)

Qty 1 Sensor - Beginning

1 7/16” (37mm)Qty 3+ Sensor - For spacing between sensors, please consult the sensor manufacturer.

Beginning of Run

M36LED Direct

Occupancy Vacancy Daylight Harvesting Driver Compatibility

Enlighted FS-D22 (E) See Enlighted’s website for full capabilities SR

Philips EasySense SNS102 (P) √ √ √ SR

Sensor Switch MSD EZ (S) √ √ √ DIM

Factory Presets - Sensors come from the sensor manufacturer with factory presets for each of the settings in above chart. Please see sensor manufacturers’ spec sheets for details on presets and re-programming.

Commissioning - Commissioning of sensors and installation by others. Contact sensor manufacturer for details and costs associated with commissioning the system prior to specification of sensors.

Sensor Ordering Chart

Quantity Sensor Settings*

x Number of Sensors E Enlighted FS-D22

P Philips Easy Sense SNS102

S Sensor Switch MSD EZ

1 Daylight

2 Occupancy/Vacancy

3 Daylight/Occupancy/Vacancy

* Settings not available with Enlighted

Fixture LengthLit Section*

Enlighted FS-D22 (E)Occupancy/vacancy, daylight harvesting, plus the Internet of Things (IoT) data collection and reporting. For full details, please see FS-D22 spec sheet on the Enlighted website. Must be paired with Philips Xitanium SR driver (SR driver selection). Commissioning by Enlighted. *Please contact Enlighted for complete details prior to specifying. *Sensor can control up to 4 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths.

Philips EasySense SNS102 (P)Occupancy/vacancy and daylight harvesting. Sensor can be programmed on-site via NFC or IR using Android app only, by others. For full details, please see the SNS102 spec sheet on the Philips website. Must be paired with Philips Xitanium SR driver (SR driver selection). Wall dimming via wireless wall switch from Philips/Illumra (www.illumra.com/easysense). **Please contact Philips for complete details prior to specifying. *Sensor can control up to 10 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths.

Sensor Switch MSD EZ (S)Occupancy/vacancy and daylight harvesting. For full functionality and programming options, select settings option 3. If a different settings option is selected, other settings may be unavailable. For full details, please see MSD EZ spec sheets on the Sensor Switch website. Must be paired with eldoLED 0-10V driver (DIM driver selection). Manual control of dimming not available with MSD EZ sensor. *Please contact Sensor Switch for complete details prior to specifying.*Sensor can control up to 30 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths.

Standard Sensor Placement - for other placement options, please consult factory. For functionality and limitations, please see sensor details above.

Aluminum Sensor Plate -to be painted same as fixture unless specified otherwise

Qty 2 Sensor - Beginning and End (9’ fixtures and longer)

Notes: 1. For spacing between sensors, please consult the sensor manufacturer. 2. Exact sensor placement and coverage will be defined by approved factory drawing. 3. Sections controlled by sensors may not be symmetrical - consult factory for layout.

* Lit section will be the fixture length minus 3” for sensor plate.

Page 10: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 10 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Listed below are the minimum lengths and details for standard shapes. These standard shapes can be combined with each other and/or the standard luminaire lengths, ensuring full even illumination. If you have any questions, please consult the factory.

The minimum standard lengths for “L” shapes:- IL90 or V90 open shapes is 4’ x 4’ nominal (example: leg, 90, leg)- IL90 or V90 closed shapes is 6’ x 6’ nominal (example: 90, leg, 90)( Exception is that the IL90 & V90’s can be joined directly to provide a 4’ x 4’ nominal shape).

*For sensors in configurations, please consult factory.

Standard Direct shapes/configurations:

The minimum standard lengths for “T” & “X” shapes:- IT90 = 4’ nominal on the short leg and 8’ nominal on the long side- IX90 = 8’ nominal for either direction

Selux is capable of supplying a wide range of project solutions including different shapes, angles, and sizes to meet the project requirements. Due to the complex nature of these project specific layout(s) we ask that you please consult the factory with the project requirements for review.

Project Specific Direct shapes/configurations:

"B" Housing

"B"

Hou

sing

"B1" Housing

"B1"

Hou

sing

"E" Housing

"E"

Hou

sing

"E1"

Ref

.

"E1" Ref."C" Housing

"D"

Hou

sing

"D1"

Ref

.

"C1" Ref.

"A" Housing

"A"

Hou

sing

"A1" Housing

"A1"

Hou

sing

IL90 - Lit Horizontal corner

V90 - Lit Inside corner

IT90 - Lit "T" section IX90 - Lit "X" section

BottomView

BottomView

BottomView

SideView

Direct Lit Corner and Section - Dimensions

IL90 V90 IT90 IX90

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

“A” Housing (Outside) 2' - 13/16" 631

“A1” Housing (Inside) 1' - 11 3/8" 594

“B” Housing (Outside) 2' - 2 5/16" 669

“B1” Housing (Inside) 1' - 11 1/2" 597

“C” Housing 2' - 13/16" 631

*“C1” Ref. 2' - 1/8" 612

“D” Housing 4' - 3/16" 1224

* “D1” Ref. 2' - 1/8" 612

“E” Housing 4' - 3/16" 1224

* “E1” Ref. 2' - 1/8" 612

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance.

Page 11: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 11 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

259

517

776

1034

1

2

Maximum Candela = 1034 Located At Horizontal Angle = 90, Vertical Angle = .5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

LW Optics / 36W LED / 4000K CCT

M36LED Direct

Photometry

447

893

1340

1786

1

2

Maximum Candela = 1786 Located At Horizontal Angle = 90, Vertical Angle = 9.5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

MI Optics / 36W LED / 4000K CCT

Catalog #: L36-1B35-40-MI-X-04-XX-UNVReport #: 11684969.03 Delievered Lumens: 2950 Input Watts: 36.64WEfficacy: 81 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 1786 @ 9.5° from VerticalSpacing Criterion (0-180): 1.22 Spacing Criterion (90-270): 1.02 Spacing Criterion (Diagonal): 1.08

Catalog #: L36-1B35-40-LW-X-04-XX-UNVReport #: 11684969.01 Delievered Lumens: 2887 Input Watts: 36.74WEfficacy: 79 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 1034 @ .5° from VerticalSpacing Criterion (0-180): 1.24 Spacing Criterion (90-270): 1.24 Spacing Criterion (Diagonal): 1.38

381

761

1142

1522

1

2

Maximum Candela = 1522 Located At Horizontal Angle = 90, Vertical Angle = 6.5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

NB Optics / 36W LED /4000K CCT

Catalog #: L36-1B35-40-NB-X-04-XX-UNV Report #: 11684969.05 Delievered Lumens: 3529 Input Watts: 36.67WEfficacy: 96 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 1522 @ 6.5° from VerticalSpacing Criterion (0-180): 1.22 Spacing Criterion (90-270): 1.14 Spacing Criterion (Diagonal): 1.26

Page 12: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 12 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Photometry

A2 Optics / 36W LED / 4000K CCT

A5 Optics / 36W LED / 4000K CCT

Catalog #: L36-1B35-40-A5-X-04-XX-UNVReport #: 11684969.06 Delievered Lumens: 3660 Input Watts: 36.73WEfficacy: 95 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 2219 @ 3° from VerticalSpacing Criterion (0-180): 1.10 Spacing Criterion (90-270): 0.84 Spacing Criterion (Diagonal): 1.00

BW Optics / 36W LED / 4000K CCT

Catalog #: L36-1B35-40-BW-X-04-XX-UNVReport #: 11684969.04 Delievered Lumens: 3193 Input Watts: 36.65WEfficacy: 87 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 1388 @ 40.5° from VerticalSpacing Criterion (0-180): 1.28 Spacing Criterion (90-270): 2.36 Spacing Criterion (Diagonal): 1.98

347

694

1041

1388

1

2

Maximum Candela = 1388 Located At Horizontal Angle = 90, Vertical Angle = 40.5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

555

1110

1664

2219

12

Maximum Candela = 2219 Located At Horizontal Angle = 90, Vertical Angle = 3# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

621

1241

1862

2482

1

2

Maximum Candela = 2482 Located At Horizontal Angle = 0, Vertical Angle = 20# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

Catalog #: L36-1B35-40-A2-X-04-XX-UNVReport #: 11684969.07 Delievered Lumens: 3647 Input Watts: 36.69W Efficacy: 99 Power Factor: 0.990 Total Harmonic Distortion: 4.63 CCT: 3982KCRI: 83.9Max Candela: 2482 @ 20° from VerticalSpacing Criterion (0-180): 1.66 Spacing Criterion (90-270): 1.24 Spacing Criterion (Diagonal): 1.44

Page 13: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 13 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Photometry

M36LED Direct

LU Optics / 36W LED / 4000K CCT

Catalog #: L36-1B35-40-LU-X-04-XX-UNVReport #: 11684993.02 Delievered Lumens: 3102 Input Watts: 38.04WEfficacy: 82 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 1002 @ 1° from VerticalSpacing Criterion (0-180): 1.26 Spacing Criterion (90-270): 1.26 Spacing Criterion (Diagonal): 1.38

DR Optics / 36W LED / 4000K CCT

Catalog #: L36-1B35-40-DR-X-04-XX-UNVReport #: 11684993.01 Delievered Lumens: 3422 Input Watts: 37.95WEfficacy: 90 Power Factor: 0.989 Total Harmonic Distortion: 10.1 CCT: 3896KCRI: 95.7Max Candela: 600 @ 26.5° from VerticalSpacing Criterion (0-180): 1.26 Spacing Criterion (90-270): 1.62 Spacing Criterion (Diagonal): 1.62

150

300

450

600

1

2

Maximum Candela = 600.1 Located At Horizontal Angle = 90, Vertical Angle = 26.5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

251

501

752

1002

1

2

Maximum Candela = 1002 Located At Horizontal Angle = 0, Vertical Angle = 1# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

Page 14: M36 LED Direct [L36] · PDF filePage 2 of 14 (Rev. 09/2017) M36LED Direct_v[1B]3.2. In a continuing efiort to ofier the best product possible, we reserve the right to change, without

Page 14 of 14 (Rev. 09/2017)

M36LED Direct_v[1B]3.2

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M36LED Direct

Photometry

CCT and CRI multipliers apply to the photometry, IES files, and per foot values listed on page one (light engine).

Light engine multiplier supplied for per foot values listed on page one (light engine).

4000K3500K3000K2700K

LightEngine Lumens Wattages1B45 1.258 1.2851B40 1.137 1.1401B35 1.000 1.0001B30 0.855 0.8381B25 0.766 0.7401B20 0.578 0.552

LWMINBA2A5BWLUDRVWVMVCVB 0.000

L36LEDDirectPhotometryMultiplierTable

CCTMultiplier

LightEngineMultiplier

1.0000.9720.9630.931

1.0221.2221.2681.2631.1061.0741.1850.0000.0000.000

LensMultiplier1.000