Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2 IE ASCON spa 20021 Bollate (Milan) Italy via Falzarego, 9/11 Tel. +39 02 333 371 Fax +39 02 350 4243 http://www.ascon.it e-mail [email protected] ASCON spa ISO 9001 Certified U L C US LISTED

M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Embed Size (px)

Citation preview

Page 1: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Hot runner temperature controller1/16 DIN - 48 x 48

M2 line ccU s e r m a n u a l • M . I . U . M 2 - 2 / 0 3 . 0 1 • C o d . J 3 0 - 4 7 8 - 1 A M 2 I E

ASCON spa20021 Bollate(Milan) Italyvia Falzarego, 9/11Tel. +39 02 333 371 Fax +39 02 350 4243http://www.ascon.ite-mail [email protected]

ASCON spa

ISO 9001C e r t i f i e d

ULC US

LISTED

Page 2: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Hot runner temperature controller1/16 DIN - 48 x 48

M2 line cc

274.8275.0

123

2

MANSP2REM

ULC US

LISTED

Page 3: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

2

Information

ccNOTES

ON ELECTRIC

SAFETY AND

ELECTROMAGNETIC

COMPATIBILITY.

Please, read carefully these instructions before proceeding withthe installation of the controller.Class II instrument, rear panel mounting.

This controller has been designed with compliance to:Regulations on electrical apparatus (appliance, systems and installa-tions) according to the European Community directive 73/23/EEC amend-ed by the European Comunity directive 93/68/EEC and the Regulationson the essential protection requirements in electrical apparatus EN61010-1 : 93 + A2:95.

Regulations on Electromagnetic Compatibility according to theEuropean Community directive n089/336/EEC, amended by the EuropeanCommunity directive n° 92/31/EEC, 93/68/EEC, 98/13/EECand the following regulations:Regulations on RF emissionsEN61000-6-3 : 2001 residential environmentsEN61000-6-4 : 2001 industrial environmentsRegulation on RF immunity EN61000-6-2 : 2001 industrial equipment and system

It is important to understand that it’s responsibility of the installer to ensurethe compliance of the regulations on safety requirements and EMC.This device has no user serviceable parts and requires special equipmentand specialised engineers. Therefore, a repair can be hardly carried ondirectly by the user. For this purpose, the manufacturer provides techni-cal assistance and the repair service for its Customers. Please, contact your nearest Agent for further information.All the information and warnings about safety and electromagneticcompatibility are marked with the B sign, at the side of the note.

Page 4: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

3

Table of contents

1 INSTALLATION .............................................................................................................................Page 42 ELECTRICAL CONNECTIONS.......................................................................................Page 83 PRODUCT CODING ................................................................................................................Page 164 OPERATIONS................................................................................................................................Page 205 AUTOMATIC TUNING ..........................................................................................................Page 386 SPECIAL FUNCTIONS ........................................................................................................Page 407 TECHNICAL SPECIFICATIONS.....................................................................................Page 45

TABLE OF CONTENTS

Main universal input

Control Alarms

Resources

OP1PV

AUX OP2

Setpoint

OP3

Operating mode

2 Single OP2 OP1 OP3action

3 Double OP1 OP3 OP2action

4 Double OP1 OP2 OP3action

5 Double OP2 OP3 OP1action

1 Single OP1 OP2 OP3action

M2

Fuzzy tuning with automatic selection

One shotAuto tuning

One shotNatural Frequency

Special functions

Auxiliary input (option)

Digital input (option)IL

IL connected functions

Continuous tuning

Adaptive

(option)

(option)

Page 5: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

4

1 - Installation

1 INSTALLATION

Installation must only be carriedout by qualified personnel.

Before proceeding with the instal-lation of this controller, follow theinstructions illustrated in this man-ual and, particularly the installationprecautions marked with the Bsymbol, related to the EuropeanCommunity directive on electricalprotection and electromagneticcompatibility.

BTo prevent hands or metal touch-ing parts that may be electricallylive, the controllers must beinstalled in an enclosure and/orin a cubicle.

1.1 GENERAL DESCRIPTION

IP 20 Terminal BlockEN61010 - 1 (IEC1010 - 1)

Product code label

Sealing front panel gasket

Mounting clamps

Panel surface

Front panelIP65 protection

EN 650529 (IEC 529)

Page 6: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

5

1 - Installation

1.2 DIMENSIONAL DETAILS

48 mm1.89 in

120 mm4.72 in

48 mm1.89 in

20 mm max0.79 in max

1.3 PANEL CUT-OUT

65 mm min2.56 in min

45+0.6 mm1.78+0.023 in

45+

0.6

mm

1.78

+0.

023

in

65 m

m m

in2.

56 i

n m

in

Page 7: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

6

1 - Installation

Special conditions

M Altitude > 2000 m

T Temperature >50°C

%Rh Humidity > 95 %

P Conducting atmosphere Use filter

Warm up

Use forced air ventilation

Use 24V~ supply version

Suggestions

Forbidden Conditions D

C Corrosive atmosphere

E Explosive atmosphere

Operating conditions

M Altitude up to 2000 m

T Temperature 0… 50°C

%Rh Relative humidity 5… 95 % non-condensing

1.4 ENVIRONMENTAL RATINGS B

Page 8: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

7

1 - Installation

1.5.1 INSERT THE INSTRUMENT

1 Prepare panel cut-out2 Check front panel gasket posi-

tion3 Insert the instrument through

the cut-out

UL note

[1] For Use on a Flat Surface ofa Type 2 and Type 3 ‘raintight’Enclosure.

1.5.2 INSTALLATION SECURING

1 Fit the mounting clamps2 Push the mounting clamps

towards the panel surface tosecure the instrument

1

3

2

1.5.3 CLAMPS REMOVING

1 Insert the screwdriver in the clipsof the clamps

2 Rotate the screwdriver

1

2

1.5.4 INSTRUMENT UNPLUGGING B

1 Push and 2 pull to remove the instrument

Electrostatic discharges can dam-age the instrumentBefore removing the instrument the

operator mustdischarge himselfto ground

1

2

1

1MΩ

1.5 PANEL MOUNTING [1]

1

1

2

Page 9: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

8

2 - Electrical connections

2 ELECTRICALCONNECTIONS

UL note[1] Use 60/70 °C copper (Cu) con-

ductor only.

2.1 TERMINATION UNIT [1] B

16 screw terminals

Option terminals

Holding screw 0.5 Nm

Pin connectorq 1.4 mm0.055 in max

ØFork-shapeAMP 165004Ø 5.5 mm - 0.21 in

Stripped wireL 5.5 mm - 0.21 in

Terminals

L

0,5Nm

6

5

4

3

2

1

12

11

10

9

16

15

18

17

14

13

Positive screwdriver PH1Negative screwdriver 0,8 x 4 mm

6

5

4

3 9

2

1

12

11

10

18

17

16

15

14

13

RTD

N

L

B

TAO

P3NO

C

OP

2-RNO

C

NO

COP

1

OP

2-L

bTC

mA mV

A

11

9 LOGICINPUT

Rear terminal

cover

5.7 mm0.22 in

Wire size1 mm2 (18 AWGSolid/Stranded)

Page 10: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

9

2 - Electrical connections

PRECAUTIONS B

Despite the fact that the instrumenthas been designed to work in anharsh and noisy environmental(level IV of the industrial standardIEC 801-4), it is recommended tofollow the following suggestions.

AAll the wiring must comply with thelocal regulations.

The supply wiring should be rout-ed away from the power cables.Avoid to use electromagnetic con-tactors, power Relays and highpower motors nearby.Avoid power units nearby, espe-cially if controlled in phase angle

Keep the low level sensor inputwires away from the power linesand the output cables.If this is not achievable, use shield-ed cables on the sensor input, withthe shield connected to earth.

2.2 PRECAUTIONS AND ADVISED CONDUCTOR COURSE B

BB

6

5

4

3

2

1

12

11

10

9

L

N

C D

16

15

B B

6

5

4

3

2

1

12

11

10

9

L

N

C D

16

15

B

18

17

14

13

18

17

14

13

C C

A A

A = SupplyB = OutputsC = Analog

inputsD = Logic

input/output

Conduit for supply and output cables

Conduit for low level sensor cables

Page 11: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

10

2 - Electrical connections

2.3 EXAMPLE OF WIRING DIAGRAM (HEAT COOL CONTROL) B

Fuse[5]

6

Power supply

CT Current transformer 50 mA

Fuse[5]

Powersupplyswitch

OP2

OP1

V~

PTC [4]

5

4

3

2

1

12

11

10

9[6]

16

15Fuse 2A~T

[6]

Alarm

V~OP2

18

17

14

13OP3 [6]

V~

TC

HeatingV~

V~Cooling

[3]

Notes:1] Make sure that the power supply

voltage is the same indicated onthe instrument.

2] Switch on the power supply onlyafter that all the electrical con-nections have been completed.

3] In accordance with the safety reg-ulations, the power supply switchshall bring the identification of therelevant instrument. The powersupply switch shall be easilyaccessible from the operator.

4] The instrument is is PTC pro-tected. In case of failure it is sug-gested to return the instrument tothe manufacturer for repair.

5] To protect the instrument internalcircuits use:- 2 A~ T fuses for Relay outputs

6] Relay contacts are already pro-tected with varistors.Only in case of 24 V ~ induc-tive loads, use model A51-065-30D7 varistors (on request)

Page 12: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

11

2 - Electrical connections

2.3.1 POWER SUPPLY B

Switching power supply with mul-tiple isolation and internal PTC• Standard version:

nominal voltage:100 - 240V~ (- 15% + 10%)Frequency 50/60Hz

• Low Voltage version:Nominal voltage: 24V~ (- 25% + 12%)Frequency 50/60Hz or 24V– (- 15% + 25%)

• Power consumption 3VA max

L

N

1

2

Included PTC

Supply

2.3.2 PV CONTROL INPUT B

A For L-J-K-S-T thermocouple type• Connect the wires with the

polarity as shown• Use always compensation cable

of the correct type for the ther-mocouple used

• The shield, if present, must beconnected to a proper earth.

B For Pt100 resistance thermometer

• If a 3 wires system is used, usealways cables of the same diam-eter (1mm2 min.) (line 20 Ω/leadmaximum resistance)

• When using a 2 wires system, usealways cables of the same diam-eter (1,5mm2 min.) and put ajumper between terminals 5 and 6

C For ∆T (2x RTD Pt100) SpecialAWhen the distance between

the controller and the sensoris 15 mt. using a cable of 1.5mm2 diameter, produces anerror on the measure of 1°C(1°F).

R1 + R2 must be <320Ω

Wire resistance150Ω max

For 3 wires onlyMaximumresistance/line 20Ω

Use wires of thesame length and1.5 mm2 size.Maximumresistance/line 20Ω

5

6

12

A

B

A

R1

R2

5

6

12

B

b

A

5

6

Page 13: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

12

2 - Electrical connections

D For mA, mV

Rj >10MΩ

mV mA5

6External

Shunt 2.5Ω

2.3.2 PV CONTROL INPUTB

2.3.3 AUXILIARY INPUT (option) B

For current transformer CTNot isolatedFor the measure of the load cur-rent (see page 34)

• Primary coil10A…100A• Secondary coil 50mA default

100mA jumper selectable

18

17

10…100A50/100mA

loadCT

~

5 watt burden resistor0.5Ω for 1A secondarytransformer coil0.1Ω for 5A secondarytransformer coil

Jumper for 100 mA

secondary transformer coil

2.3.4 DIGITAL INPUT (option) (page 35) B

• The input is active when thelogic state is ON, correspond-ing to the contact closed

• The input is inactive when thelogic state is OFF, correspond-ing to the contact open

11

10

9

TTLopen

collector

NPNopen collector

IsolatedcontactCom.

IL 1 C1

• To use with APG2-DRSPCboard, see page 40.

Page 14: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

13

2 - Electrical connections

2.3.5 OP1 - OP2 - OP3 OUTPUTS B

The functionality associated to each of the OP1, OP2 and OP3 input is definedduring the configuration of the instrument index l(see page 18).The suggested combinations are:

OP2 output can be Relay (Std) orlogic (option).The “jumper” on the auxiliaryboard selects the output type:

Link Pins 1-2 for OP2-RelayLink Pins 2-3 for OP2-Logic

Note[1] With heat / cool control AL2 and AL3 share in or mode the same output

(the free one).

12

3

Jumper

Auxiliaryboard

AlarmsAL2

OP1Heat OP2-R OP3

OP2-LHeat OP1 OP3

OP1Heat

OP3Cool

OP2-R[1]

OP1Heat

OP2-LCool

OP3[1]

OP2-LHeat

OP3Cool

OP1[1]

AL3

Doubleaction

Doubleaction

Doubleaction

Singleaction

Singleaction

Control outputs

E

D

C

B

A

OP1 - OP3

OP2 - R

Relay output

Relay outputOP2 - L Logic output

Page 15: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Heatload

Staticrelay

10

11

OP2

14

2 - Electrical connections

Relay output• SPST Relay N.O., 2A/250 V~

for resistive load, fuse 2A ~ T

Logic output not isolated • 0…5V–, ±20%, 30 mA max

2.3.5-A SINGLE ACTION RELAY (TRIAC) CONTROL OUTPUT B

2.3.5-B SINGLE ACTIONLOGIC CONTROL OUTPUT B

2.3.5-C DOUBLE ACTION RELAY/RELAY CONTROL OUTPUT B

2.3.5-D DOUBLE ACTION RELAY/LOGIC CONTROL OUTPUT B

2.3.5-E DOUBLE ACTION LOGIC/RELAY CONTROL OUTPUT B

LoadStaticrelay

10

11

OP2

Fuse

Coil of theheat loadcontactor

3

4OP1

Fuse

Coil of theheat loadcontactor

3

4OP1

Fuse

Coil of theheat loadcontactor

3

4OP1

Fuse

Coil of thecool loadcontactor

13

14OP3

Fuse

Coil of thecool loadcontactor

13

14OP3

Coolload

Staticrelay

10

11

OP2

Varistor forinductive load24V~ only

Varistor forinductive load24V~ only

Varistor forinductive load24V~ only

Varistor forinductive load24V~ only

Page 16: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

15

2 - Electrical connections

2.3.6 ALARMS OUTPUTSB

Fuse

Coil of theload alarm contactor

3

4OP1

Fuse

Coil of theload alarm contactor

15

16OP2

Fuse

Coil of theload alarm contactor

13

14OP3

e The outputs OP1, OP2 (Relayoptional) and OP3, can be usedas alarm outputs only if they arenot configured as control outputs.

Varistor for inductive load24V~ only

Page 17: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

16

3 - Product coding

3 PRODUCT CODING

The complete code is shown onthe instrument label. The informa-tions about product coding areaccessible from the front panel bymean of a particular proceduredescribed at section 4.2.2 page 21

L

C D

M N

B

P/NCONFS/NV~(L-N).100÷240V 50/60 Hz - 2,6W

: M2-3600-0000: 2002: A0A-9909/0013

3600Hard

123

2

MANSP2REM

Basic product code (hardware)

Instrument Label

Configuration code (software)

Page 18: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

17

3 - Product coding

3.1 MODEL CODE

The product code indicates the specific hardware configuration of the instrument, that can be modified, byspecialized engineers only.

Line Basic Accessories Configur.

M 2 A B C D - E F G 0 / I L M NModel:

Power supply A100 - 240V~ (- 15% + 10%) 324V~ (- 25% + 12%) or 24V– (- 15% + 25%) 5

Line 2M

Front panel colour GDark (std) 0Beige 1

User manual FItalian/English (std) 0French/English 1German/English 2Spanish/English 3

Only Logic 6

OP2 Outputs BRelay and Logic 1

CT [1]

Digital input DOptions

Not fitted 0None

9 3Fitted 0None

C0

93Current transformer input (CT) [1] 0

Digital remote setpoint control + Safety average OP on sensor break 8Safety average OP on sensor break 7

Special functions ENot fitted 0SP Raise/Lower by digital input 6

[1] Only for B=1

Page 19: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

18

3 - Product coding

3.2 CONFIGURATION CODING

The configuration code consists of4 digits that identify the operat-ing characteristic of the controller,as chosen by the user.Section 4.6 at page 35 reports theinstructions how to set a new con-figuration code.

The configuration code can be dis-played on the front panel, follow-ing the instructions at page 21 sec-tion 4.2.2.

I L M N

Conf2002

Input type and range ITR Pt100 IEC751 0TR Pt100 IEC751 1TC L Fe-Const DIN43710 2TC J Fe-Cu45% Ni IEC584 3TC T Cu-CuNi 4TC K Cromel -Alumel IEC584 5TC S Pt10%Rh-Pt IEC584 6DC input 0…50 mV, linear 7DC input 10…50 mV, linear 8Custom input and range [1] 9

-328…752 °F32…2192 °F32…2912 °F

-99.9…572.0 °F-328…1112 °F32…1112 °F32…1112 °F

-200 …400 °C0…1200 °C0…1600 °CEngineering units

-99.9…300.0 °C

Engineering units

-200…600 °C0…600 °C0…600 °C

Control action type MReverse (single action)Direct (single action)

0Linear Cool (Heat/Cool double action)1On-Off Cool (Heat/Cool double action)

Heat/Cool action

67

Control mode Output configuration [1] L

Control OP1- OP3 / alarm AL2 on OP2

PID 0

Control OP1- OP2 / alarm AL2 on OP3

Control OP1 / alarm AL2 on OP21Control OP2 / alarm AL2 on OP1

On - Off 2Control OP1 / alarm AL2 on OP23Control OP2 / alarm AL2 on OP1

Control OP2- OP3 / alarm AL2 on OP1 8

[1] For instance, other thermocouples types, ∆T (with 2 PT 100), custom lineari-sation etc.

Page 20: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

19

3 - Product coding

AIf, when the controller is poweredup for the first time, the displayshows the following message

it means that the controller hasnot been configured yet.

The controller remain in stand-byuntil the configuration code is setcorrectly (see chapter 4.6 page 35).

9999Conf

123

4

Alarm 2 type and function NDisabled 0Sensor break alarm / Loop Break Alarm

Absolute 2active high3active low

Deviation active high 4active low 5

Bandactive out 6active in 7

Heater break by CT [2]

active during ON output state 8active during OFF output state 9

1

For alarm 3 type and function see page 34

Note [2] Only with CT options.

Deviation active high

Heater break by CT [2]

4

active during ON output state

active low

Alarm 3 type and function O

8

Disabled 0

5

Band

Sensor break alarm / Loop Break Alarm 1

Absolute 2active high

active during OFF output state

3active low

active out

9

6active in 7

Page 21: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

20

4 - Operations

4 OPERATIONS 4.1.A KEYS FUNCTIONS AND DISPLAY IN OPERATOR MODE

274.8275.0

123

MAN

Setpointsetting

OP1 output ONOP2 output ONOP3 output ON

Menuaccess

Enter key forselection andvalue settingconfirmation

PV control inputin engineeringunits

OperatingSetpoint

(At the poweron the target

Setpoint valueis displayed

for 3 seconds)

Output statusLEDs(red):

When the measuredvalue is greater thansensor high range

2

When the measuredvalue is less than thesensor low range

Fuzzy Tuning running(green):blinkingManual

operating mode(green): steady

SP2Stand-by

Setpoint enable(green): steady

REM

Digital remoteSetpoint control

(see page 40)

Valuesmodification

Enter key forselection andvalue settingconfirmationAccess to the

menu for:- configuration- parameter setting

Parameter value

Parameter mnemonic

35.0p.b.

123

A / M

2

4.1.B KEYS FUNCTIONS AND DISPLAY IN PROGRAMMING MODE

Page 22: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

21

4 - Operations

4.2 DISPLAY

During the operation, the para-meters values cannot be modi-fied by the user

4.2.1 OF THEPROCESS VARIABLES

4.2.2 OF THE CONFIGURATIONCODES

275..0274.8

°C274.8

Out 63.4

t.Cur 47

s.p.275.0

Operator mode

Engineeringunits [1]

OP1 output(auto) [2]

Load current [3]

Local Setpoint (manual)

Note[1] See table page 37[2] This display is not presented if the

instrument has been configured asan On - Off controller

[3] Value in Ampere. Only with CToption (see page 34)

°C274.8

275..0274.8

Hard3600

Conf2002

rel. 00A

Operator mode

Engineeringunits [1]

Basic product code (see page 16)

Configurationcode (see page 18)

Software release

Example: M2 - 3600 - 2002 / Release 00A

Page 23: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

22

4 - Operations

Operatormode working Setpointdisplayed

Local Setpoint display

Setpoint modification

Setpoint entry.The operation isacknowledged byone flash of the display.

4.3 PARAMETER SETTING

Press $ or % momentarily tochange the value of 1 unit everypushContinued pressing of $ or %changes the value, at rate thatdoubles every second. Releasingthe button the rate of changedecreases.In any case the change of the valuestops when it has reached themax/min limit set for the parameter.

In case of Setpoint modification: press $ or % once to displaythe local Setpoint instead of work-ing Setpoint.To evidence this change the dis-play flashes once. Then theSetpoint can be modified

4.3.1 NUMERIC ENTRY(i.e. the modification of the Setpoint value from 275.0 to 240.0 )

after 2 s

—Lower

—Raise

275.0274.8

275.0274.8

230.0274.8

240.0274.8

240.0 °C

Page 24: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Unit °C

Unit °f

Unit °C

Unit °f

Unitnone

Unit ph

23

4 - Operations

Engineering UnitsDegree Centigrade

Degree Fahrenheit

Degree Centigrade

Degree Fahrenheit

no unitsdefined

Ph

4.3.2 MNEMONIC CODES SETTING (e.g. configuration see page 35)

Press the $ or % to display the next or previous mnemonic forthe selected parameter. Continued pressing of $ or % will display further mnemonics at arate of one mnemonic every 0.5 s. The mnemonic displayed at the timethe next parameter is selected, is the one stored in the parameter.

4.3.3 KEYPAD LOCK

To lock/unlock the keypad pressthe keys í and è simulta-neously for 2 seconds.To confirm the keypad lock/unlockthe display flashes once.

The keypad lock/unlock can beachieved by serial communicationstoo.

AThe keypad lock is main-tained in case of powerfailure.

274.8275.0

2

operator mode

Press simultaneouslyfor 2 seconds

Page 25: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

24

4 - Operations

4.3.4 OUTPUTS LOCK

The outputs are switched to theOFF status by pressing the keysè and %together.When the outputs are locked , themessage #Off is displayedinstead of the Setpoint value.To unlock the outputs press againthe keys simultaneously (the Soft-start will be enabled).

The outputs lock/unlock can beachieved by serial communica-tions too

AThe outputs lock/unlock ismaintained in case ofpower failure.

274.8OFF

2

operator mode

Press simultaneouslyfor 2 seconds

4.3.5 AUTO / MAN

• Press è to confirm. Back to operator mode.

• The led shows the manualmode status.

• When manual mode is active,the Setpoint display shows theoutput value, that can be mod-ified by $ %

MAN

A.ManAuto

275..0274.8

A.ManMan

Operator mode

Select #Manto switch to manual mode

Select #Autoto switch to automaticmode

4.3.5 DIGITAL REMOTE SETPOINT CONTROL

(code E=6 or 8, see pag. 17)Holding pressed simultaneously fortwo second the % and è keysthe Setpoint raise/lower functioncomes inhibited to indefinite time.The return to the full functionality ispossible still pressing simultane-ously for two second the% andè keys.

AThe raise/lower function lock ismaintained in case of power fail-ure

274.8275.0

2

operator mode

Press simultaneouslyfor 2 seconds

Page 26: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

275..0

é 5:0

t.i.

é 5:0

p.b.

é 0

A3s.p

274.8 A.Man

O.C.

t.c.

é 1:00

t.d.

é 20

é 1:00

25

4 - Operations

4.4 PARAMETERISATION

AThe parameter setting procedurehas a timeout. If no keys arepressed for, at least, 30 seconds,the controller switches back, auto-matically, to the operator mode.

After having selected the parame-ter or the code, press $ and %to display or modify the value (seepage 22) The value is entered whenthe next parameter is selected, bypressing the è key.

Pressing the í key, the next groupof parameters is presented on thedisplay.

Valuesmodification

Modification/selection

enter

Prametermenu

selection

35.0p.b.

Parametervalue

Parametermnemonic

M2 Operator modeAuto/Manselection(see page 24)

AL3 alarm threshold [1](see page 28)

Proportional band(PID algorithm only)0.5…999.9% of span

Integral time (PID algorithm only)0ff / 0.1…100.0 min

Derivative time (PID algorithm only)0.5…999.9% of span

Cycle time(Time proportioning only)1…200 s

Overshoot control(PID algorithm only)0.01…1.00

Note[1] It is not presented if the con-

troller has been configuredwith alarm n° 2 not active orof sensor break type. DigitN/M of the configurationcode is assigned to 0 or 1.

[2] These values are not auto-matically stored on the PIDmenu parameters P.b., t.i, t.d.

Page 27: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

tune

5000

é 0:5

d.bnd

é100:0

Op. H

é100:0

Op.HC

hy.é 0:5

hy. C

r.C.Ga

é 20

t.c. C

é 33

pAssé 0

A2s.p

OK

é 1:0

é 0:5

p.b. a

T.i. A

ADPT

26

4 - Operations

Cool cycle time (heat/cool with cool timeproportioning only)1…200 s

Cool relative gain (heat/cool configuration only)0.1…10.0

Cool output hysteresis (On-Off control only)0.1…10.0% range

Password entryonly if Code value≥5000 (see pages 35…37)

1st GROUPAL2 alarm threshold [1](see page 28)

Dead band(heat/cool configuration only)-10.0…10.0%

Control output high limit(PID algorithm only)10.0…100.0%

Cool control output high limit(heat/cool PID configuration only)10.0…100.0%

Control output hysteresis(On-Off control only)0.1…10.0% of span

2nd GROUPTuning run/stop (PID algorithm only)

Continuous Tuning start(adaptive tuning)(PID algorithm only) PrGh

Calculated Proportional band [2] (display only)(available when adaptivetuning is selected)

Calculated Integral Time[2] (display only)(available when adaptivetuning is selected)

PARAMETER MENU

Back to the 1st parameter group

Code entryfrom 5000 to 9999Must be equal to thevalue of the parame-ter Code

YESNO

Page 28: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

éF.sécala

é 0

é Off

é Off

éIn.sécala

t.d. Aé I

s.p. 2

sl. u

sl. d

s.p. l

s.p. H

s.p.In

é 0:5

A2hy

énone

A2L.béH. r éange

éL. r éange

27

4 - Operations

Calculated derivativetime [2] (display only)(available when adaptivetuning is selected)

Stand-by Setpoint s.p. l…s.p. H

Setpoint ramp up 0ff/0.1…999.9digit/min

Setpoint ramp down0ff/0.1…999.9digit/min

Setpoint low limit low range… s.p. H

Setpoint high limits.p. l…high range

Setpoint inc./decr. value by digital input(if option installed)0…full range

AL2 hysteresis0.1…10.0% of span [1]

AL2 latching and blocking functionsnone / Ltchbloc / Lt.bL

Page 29: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

28

4 - Operations

pass

énone

é Off

é Off

é Off

é Off

st.Op

é 1

st.tM

sa.Opé 0é Off

In.shA3L.b

A3hyé 0:5

t.LbA

t.Fil

d.Err

Password entryonly if Code value <5000 (see pages 35…37)

AL3 hysteresis0.1…10.0% of span [1]

AL3 latching and blocking functionsnone / Ltchbloc / Lt.bL

LBA delay(see page 31)0ff= sensor break1…9999 s LBA

Filter time constant1…30 s or Off

Input shift -60…60 digits

Error dead band (PID algorithm only)0ff/0.1…10.0 digits

Soft-start output value(PID algorithm and 0ff/0.1…100.0%

Soft-start activation time (only if st.Op different than0ff) 1…9999 s

Output safety value 0.0…100.0% (not shown if E = 7 or E = 8see page 17)(-100.0…100.0% forheat/cool)

Direct access to the configuration(pages 35 … 37)

Back to the 2nd parameter group

Page 30: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

Proportional band

This parameter specifies the pro-portional band coefficient that mul-tiplies the error (SP - PV)

Integral time

It is the integral time value, thatspecifies the time required by theintegral term to generate an outputequivalent to the proportional term.When Off the integral term is notincluded in the control algorithm.

Derivativetime

It is the time required by the proportionalterm P to repeat the output provided bythe derivative term D. When Off thederivative term is not included in thecontrol algorithm.

Control output cycle time Cycle time cool

It’s the cycle time of the logic con-trol output. The PID time propor-tional control output is providedthrough the pulse width modula-tion of the digital waveform.

#t.c. C#t.c.

#t.d.

#t.i.

#p.b.

29

4 - Operations

4.5 PARAMETERS

Band alarmOnOff

Activeout

Activein

hy

SP

Full scaleFull scale

hy

Alarm threshold

OnOff

Deviation alarmOnOff

Activehigh

Activelow

hy

+ high range- low rangeAlarm threshold

OnOff

SP

Absolute alarmOnOff

Activehigh

Activelow

hy

High rangeLow rangeAlarm threshold

OnOff

T

Sensor break or input disconnection

over-range

under-range

VisualisationSensor

The controller parameters havebeen organised in group, accord-ing to their functionality area.

AL2 alarm threshold AL3 alarm threshold

The alarm occurrences handle theOP1, OP2 and OP3 outputs, in dif-ferent ways, according to the con-figured types of alarms, as illus-trated.With double action control out-put, AL2 and AL3 share in ormode the same output (the freeone) (see table on page 13)

#A3s.p#A2s.p

FIRST GROUP

Page 31: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

30

4 - Operations

Overshoot control

(Automatically disabled when theadaptive tuning is running).This parameter specifies the span ofaction of the overshoot control. Settinglower values (0.99 —> 0.01) the over-shoot generated by a Setpoint changeis reduced. The overshoot controldoesn’t affect the effectiveness of thePID algorithm. Setting 1, the over-shoot control is disabled.

Heat/Cool dead band

This parameter specifies the widthof the deadband between the Cooland the Heat channel.

Control outputhigh limitCool outputhigh limit

It specifies the maximum value thecontrol output can be set

Control outputhysteresisCool outputhysteresis#hy. C

#hy.

#Op.HC#Op. H

#d.bnd

#O.C.

Control or alarm output hysteresisspan, set in % of the full scale.

Off

SPOn

Hysteresis of the threshold

hy

Setpoint incre-ment/decrement

step value by digital input

AL2 alarm hysteresisAL3 alarm hysteresis

Hysteresis of the threshold of boththe alarms, that activate OP1 andOP2 control output. It is specifiedas a % of the full scale.

AL2, AL3 latching and blocking functions

For each alarm it is possible toselect the following functionsnone noneLtch latchingbloc blockingLt.bL both latching and blocking

#A2L.b#A3L.b

#A3hy#A2hy

#s.p.In

SECOND GROUP

Stand-bySetpoint

Setpoint ramp upSetpointramp down

This parameter specifies the max-imum rate of change of the Setpointin digit/min. When the parameter isOff, this function is disabled.

Setpoint low limitSetpoint high limit

Low / high limit of the Setpoint value.

#s.p. H#s.p. l

#sl. d#sl. u

#S.P. 2

Page 32: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

31

4 - Operations

#Ltch ALARM ACKNOWLEDGE FUNCTIONThe alarm, once occurred, is pre-sented on the display until to thetime of acknowledge. The acknowledge operation con-sists in pressing any key.After this operation, the alarmleaves the alarm state only whenthe alarm condition is no longerpresent.

#bloc START-UP DISABLING

DisableSP∆SP

OnOff

Start-up

∆SP Disable

SP

OnOff

Start-up

Ramp down

Ramp up

∆SP Threshold = SP ± range

ALARMS WITH LBA (LOOP BREAK ALARM) AND SENSOR BREAK OPERATIONSelect the code 1 on n or o configuration indexes (see pages 18 or19). The following parameter is then available:

LBA delay#t.LbASetting a value between 1 and9999 s the alarm works asLBA+Sensor break with delay [1]This condition is shown by meansa red led as well as the blinking PVdisplay.

Setting OFF the alarm works asSensor break with immediateaction.This condition is shown by meansthe red led of the selected alarm aswell as:

When the cause of the alarm disappears, the alarm status stops.

or275.08888

275.08888____ ----

Note [1] In case of sensor break, con-dition, the alarm action is immediate.

275.0274.8

mA

°C

OP1

Page 33: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

32

4 - Operations

Input filter time constant

Time constant, in seconds, of the RCinput filter applied to the PV input.When this parameter is set to Offthe filter is bypassed.

Input shift

This value is added to the measuredPV input value. Its effect is to shift thewhole PV scale of up to ± 60 digits.

Error Dead Band

Inside this band for (PV - SP), the con-trol output does not change to protectthe actuator (output Stand-by)

#d.Err

#In.sh

Filter response100%

0

PV63,2%

t.Fil Time

#t.fil Soft-startcontrol outputvalue

Value of the control output duringthe Soft-start activation time.

Soft-startactivation time

Time duration (starting from thepower on) of the Soft-start func-tion.

Soft-startphase

100%

Start up

#St.tM

#St.OP

OP

Time

#st.tM

#St.OP OutputSafety Value

Output Value in case of inputanomalyNot shown if E = 7 or E = 8 (seepage 17)

#Sa.OP

SECOND GROUP

Page 34: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

33

4 - Operations

By a sole PID control algorithm, thecontroller handles two different out-puts, one of these performs theHeat action, the other one the Coolaction.It is possible to overlap the out-puts. The dead band parameter #d.bnd,is the zone where it is possible toseparate or overlap the Heat andCool actions.

The Cool action can be adjustedusing the relative cool gain para-meter #r.C.Ga.

To limit the Heat and Cool outputsthe parameters #0p. H and #0p.HCcan be used.

When there is an overlap, the dis-played output # OUt shows thealgebric sum of the Heat and Cooloutputs.

HEAT COOL CONTROL

A Heat /Cool actions separated

Insert positive #d.bnd value(0…10%)

B Heat /Cool actions overlapped

Insert negative #d.bnd value (-10…0%)

100%

100%

#d.b.nd

#Op.HC#Op. H

50%

Heatoutput

Cooloutput0%

0%PID output

-100%

100%

100%

#d.b.nd

#Op.HC#Op. H

50%

Heatoutput

Cooloutput0%

0%PID output

-100%

C Cool action adjustingExample with different relative coolgains

D On-Off Cool action

100%

100%

#d.b.nd

#hy. C

50%

Heatoutput

Cooloutput0%

0%PID output

On

Off

100%

100%

#d.b.nd

#r.C.Ga 0.1…10.0

50%

Heatoutput

Cooloutput0%

0%PID output

-100%

=2.0=1.0=0.5

Page 35: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

34

4 - Operations

CURRENT TRANSFORMER INPUT

With CT option it is possible to dis-play the load current and set analarm threshold.It is possible to set AL2 or AL3(index 8 and 9) to have an alarmwhen, during the ON time of thetime proportional output, the loadcurrent is less then the specifiedthreshold or, during the OFF time,there is at least 3% of full scale

load currentThe alarm condition must be longerthan 120 ms to set the alarm.During the OFF time the parame-ter tCur latches the last on timecurrent value

Example:CT input on OP1, alarm on AL2 dur-ing on time (configuration digit N = 8)

ON ON

ON ON

3%

A2s.p

t.Cur

120 ms 120 ms

OFFOP1

AL2 OFF OFF OFF

Load

cur

rent

Page 36: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

275..0274.8

Code

A.Man

sc.Hi

Ht.f.s

IL.Fn

Password [2]0…999933 default from factory

High range [1](linear scale only)-999…9999

Digital input function(only if installed)(see table 2)

CT primary high range(only if installed) 10…200 A

35

4 - Operations

4.6 CONFIGURATION

The configuration of the controlleris specified through a 4 digit codethat defines the type of input, ofcontrol output and of the alarms.(sect. 3.2 page 18)

Press $ or % to display thenext parameter or the next codeand change its value.The new value entered is stored intothe controller when the next para-meter is selected by pressing è.Pressing the í the next groupof parameters is displayed.

Valuesmodification

Enter key forselection andvalue settingconfirmation

Configurationmenu access

200.2Conf

Parametervalue

Parametermnemonic

M2

Operator mode Auto / Man selection (see page 24)

Page 37: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

2002

tune

I L M N

A2s.p

Con2sc.lo

sc.d.d

ConfUnit

5000

pAss

OK

Direct access to the configuration

36

4 - OperationsCONFIGURATION MENU

1st GROUP 2nd GROUP

AL3 configuration code(see table O, page 19)

Engineering units(see table 1)

N° of decimals(linear scale only)0…3

Low range [1](linear scale only)-999…9999

Entry of digits I-L-M-N of the configuration code

(chapter 3.2 page 18 and 19)

YES

NO

Password entryonly if Codevalue ≥5000

Code entryfrom 5000 to 9999Must be equal to thevalue of the parameterCode

Page 38: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

pass

33

OK

37

4 - Operations

Code entryfrom 0 to 4999 (33 default from factory)The entered password must correspond tothe one store in the Code parameter.

Password entryonly if Code value <5000

ADirect access to the configuration

A From parameterisation (see page 27).B At the first power on when the

controller is not configured:

In this situation, the controller has its outputs and inputs not active.This situation ends when a correct configuration code is entered.

Conf9999

Table 1 - Supported Engineering Units.

Notes[1] Minimum Range 100 digits.[2] To avoid free parameter access

insert 5000…9999[3] If option installed

mV nUVolt UmA MA

Centigrade degrees* °C

Ampere

Fahrenheit degrees * °f

ABar bArPSI

none none

psIRh rhpH ph* For inputs from thermocouple or

resistance thermometer, the choiceis between °C and °F only.

Stand-by Setpoint s.p. 2Remote Setpoint control [3] CuSt

Not used OffKeypad lock keb.IAuto/Man A.Man

Table 2- Digital input functions

NOYES

Page 39: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

38

5 - Automatic tuning

275..0274.8

tunestop

tunestrt

Operatormode

press until

To startselect strt

To stop select stop

Step response

SP

Natural frequency

Start of autotuneoperation

PV variable

Control output

PV variable

Control output

tuning start

End of the tuningoperating and setting of

the new calculatedterms.

Setpoint change End of the tuningoperating and setting of

the new calculatedterms.

5 AUTOMATICTUNING

Two tuning methods are provided:• Initial one shot Fuzzy-tuning • Continuous, self learning

Adaptive Tuning

The Fuzzy-Tuning allows the calcu-lation of the optimal PID terms para-meters, monitoring the response ofthe process to disturbances.The controller provides 2 types of“one shot” tuning algorithm, thatare selected automatically accord-ing to the process condition whenthe operation is started.Step responseThis type is selected when, at thestart of the autotune operation, thePV is far from the Setpoint of morethan 5% of the span.This method has the big advantageof fast calculation, with a reasonableaccuracy in the term calculation.Natural frequencyThis type is selected when the PV isclose to the SP Setpoint.This method has the advantage of

a better accuracy in the term cal-culation with a reasonable speedcalculation.The Fuzzy Tuning determinesautomatically the best method touse to calculate the PID term,according the process conditions.

The green led blinking goes onwhen the Fuzzy Tuning is inprogress. At the end of this opera-tion, the calculated PID terms para-meter are stored and used by thecontrol algorithm and the controllergoes back to the operator mode.The green led becomes off.

Page 40: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

39

5 - Automatic tuning

The self-learning Adaptive Tuningis not intrusive. It doesn’t affect theprocess, at all, during the phase ofcalculation of the optimal termsparameters.

It is particularly suitable for con-trolling process whose controlcharacteristics change withtime or are not linear in relationto the Setpoint values.It doesn’t require any operation bythe user. It is simple and works fine:it samples continuously theprocess response to the variousperturbations, determining the fre-quency and the amplitude of thesignals. On the basis of this dataand their statistical values, storedin the instrument, it modifies auto-matically the PID term parameters.It is the ideal for all applicationswhere it is required to change con-

Perturbation

Newparameters

Continuous adaptive tune

tinuously the PID terms parame-ters, in order to adjust the PID tothe changes of the processdynamic conditions.

In case of power off with theAdaptive Tuning enabled, thevalues of the PID terms para-meters are lost. At the power onthe Adaptive Tuning starts auto-matically and computes againthe values of the PID terms para-meters.

275..0274.8

Adptstop

Adptstrt

tuneStop

Operatormode

press until

press è

To startselect strt

To stop selectstop

Page 41: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

40

6 - Special functions

6 SPECIAL FUNCTIONS

Two special functions are available:6.1 Safety average OP on

sensor break6.2 Digital remote setpoint control

(Setpoint raise/lower + Stand-by Setpoint)

This function is available only if theindex E of the model code (seepage 17) engages the value 7 or 8.The averages comes effected, fil-tering the output with a first orderfilter with around 50 seconds ofconstant of time. Such filter isactive in a continuous way whenthe input is in conditions of normaloperation; in conditions of outscale the refresh of the filter comesjammed and the reached valuebecomes the output. The #Sa.OP parameter (see pages28,32) doesn't appear when theoption is enabled.

This function is available only if theindex E of the product code of themodel (see page 17) engages thevalue 6 or 8 and the digital inputoption (C index= 9) is present.The parameter of configuration#Il...fn (see page 35) allows to setthe Cust value that enable thefunction.Connecting to the digital input anoutput of the APG2- DRSPC card(see manual N. M.I.U. DRSPC J30-628-1ADRSPC) it is possible:

1. To increase the Setpoint of astep

2. To decrease the Setpoint of thesame step

3. To select the Stand-by Setpoint#S.P. 2 (see page 27)

The value of the step has givenfrom the # .S.P.In parameter (seepages 27,30).

6.1 SAFETY STATE USING THE AVERAGE OF THE OUTPUT

6.2 DIGITAL INPUT WITH REMOTE SETPOINT CONTROL

Page 42: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

41

6 - Special functions

When the option is activated the Ü led comes alight and the func-tion of the digital input it is the following:

Digital input disabled The instrument operates on local Setpoint

Raise function activation

The local Setpoint increase of the value of S.P.In, Ü led flashes threetimes to point out the operation

Lower function activationThe local Setpoint decrease of the value ofS.P.In, the Ü led flashes three times topoint out the operation

Stand-by SP selectionThe controller uses the Stand-by SetpointS.P. 2, the ä led alight points out thestate

Page 43: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

42

7 - Technical specification

7 TECHNICAL SPECIFICATIONS

Common characteristics

A/D converter with resolution of 50,000 pointsUpdate measurement time: 0.2 secondsSampling time: 0.5 secondsInput bias: - 60…+ 60 digitInput filter with enable/disable: 1…30 seconds

Accuracy0.25% ± 1 digits for temperature sensors0.1% ± 1 digits (for mV and mA)

Between 100…240V~the error is minimal

Resistance thermometer(for ∆T: R1+R2 must be <320Ω)

Pt100Ω at 0°C(IEC 751)°C/°F selectable

2 or 3 wires connectionBurnout (with any combination)

Max. wire Res: 20Ω max(3 wires)Sensitivity: 0.1°C/10° E. T.<0.1°C / 10Ω Wire Res.

Thermocouple

L,J,T,K,S(IEC 584)Rj >10MΩ°C/°F selectable

Internal cold junctioncompensation con NTCError 1°C/20°C ±0.5°CBurnout

Line: 150Ω max Input drift:<2µV/°C.Env. Temp<0.5µV / 10Ω Wire Res.

DC input (current)4…20mA,0-20mAwith external shunt 2.5ΩRj >10MΩ

Engineering unitsConf. decimal point positionInit. Sc -999…9999Full Sc. -999…9999(min. range of 100 digits)

Input drift:<0.1% / 20°C Env. Temp.

DC input (voltage)10…50mV, 0-50mVRj >10MΩ

Total configurability(see par. 3.2 page 18

par. 4.6 page 35)

PV Input(see page11,12 and page 18)

Description

From keypad the user selects:- the type of input - the associated functions and the corresponding outputs- the type of control algorithm - the type of output and the safe conditions - the type and functionality of the alarms - the values of all the control parameters.

Features(at 25°C environmental temp.)

Page 44: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

43

7 - Technical specification

Features(at 25°C environmental temp.) Description

Single action

DoubleactionHeat/cool

CT auxiliary input(option)

Current transformer(see page 12)

50 or 100 mAinput hardwareselectable

Current visualisation 10 … 200AWith 1A resolutionand Heater Break Alarm

Digital input(option)

The closure of the externalcontact produces any ofthe following actions:

Auto/Man mode change, Stored Setpoint activation, Keypad lock,Remote Setpoint Control

Operating mode and Outputs

1 doubleaction PIDloop or On/Offwith 1 or 2alarms

Control output AL2 alarm AL3 alarmOP1-Relay OP2-Logic or Relay(opt.) OP3-Relay/TriacOP2 -Logic OP1-Relay OP3-Relay/TriacOP1-Relay OP3-Relay OP2-Logic or Relay(opt.)OP1-Relay OP2 Logic OP3-Relay/TriacOP2 Logic OP3-Relay OP1-Relay

Control mode

Algorithm PID with overshoot control or On-OffProportional band (P) 0.5…999.9%

PID algorithmIntegral time (I) 0.1…100.0 min

OFF = ODerivative time (D) 0.01…10.00 min

1…200 sDead band -10.0…10.0%

Heat / cool control action

Cool relative gain 0.1…10.0

Cool cycle time 1…200 sOvershoot control 0.01…1.00

PID algorithmHigh limit 100.0…10.0% (heat) -100.0…-10.0%(cool)Hysteresis 0.1…10.0% On-Off algorithm

Error band 0.1…10.0 digitCycle time

Page 45: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

44

7 - Technical specification

OP1 output SPST Relay N.O., 2A/250V~ for resistive load

Active low

Protection by varistor for 220V ~and capacitor

OP2 outputLogic not isolated: 5V–, ± 10%, 30mA maxSPST Relay(option),N.O., 2A/250V~ for resistive load

Jumper selectable (page 13)

OP3 output SPST Relay N.O., 2A/250V~ for resistive load,

Features(at 25°C environmental temp.) Description

AL2 - AL3 alarms

Hysteresis 0.1…10.0% c.s.

Action

Active highAction type

Deviation threshold ±range

Band threshold 0…range

Absolute threshold whole range

Sensor break, heater break alarm,Latching/Blocking, Loop Break Alarm

Setpoint

Local and stand-by, digital input or serial communications

Ramp up and down. User inhibited 0.1…999.9 digit/min

Low limit from low range to high limit

High limit from low limit to high range

Tuning

Fuzzy-Tuning The controller selects automaticallythe best method according to the process conditions

Step response

Natural frequency

Auto/Man station Standard with bumpless function, by keypad, digital input or serial communications

Adaptive Tuning self-learning, not intrusive, analysis of the process response to perturbations andcontinuously calculation of the PID parameters

Page 46: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

45

7- Technical specification

Features(at 25°C environmental temp.) Description

Operational safety

Measure input Detection of out of range, short circuit or sensor break with automaticactivation of the safety strategies and alerts on display

Control output Safety value: -100%…100% or Average (option)

Parameters Parameter and configuration data are stored in a non volatile memory foran unlimited time

Access protectionPassword to access the configuration and parameters data,keypad lock, output lock

General characteristics

Power supply(fuse protected)

100 - 240V~ (- 15% + 10%) 50/60 Hz or 24V~ (- 25% + 12%), 50/60 Hz and 24V– (- 15% + 25%)Power consumption 2.6W max

Safety Compliance to EN61010-1 (IEC 1010 – 1), installation class 2 (2500V) pollution class 2, instrument class II

Electromagnetic compatibility Compliance to the CE standards (see page 2)

Protection EN60529 (IEC 529) IP65 front panel

Dimensions 1/16 DIN - 48 x 48, depth 120 mm, weight 130 gr. apx.

UL and cUL Omologation File 176452

Page 47: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

1 WARRANTY

We warrant that the prod-ucts will be free fromdefects in material andworkmanship for 3 yearsfrom the date of delivery.The warranty above shallnot apply for any failurecaused by the use of theproduct not in line with theinstructions reported on thismanual.

G.&

P. G

rafic

a &

Pub

blic

ità •

Gaz

zani

ga (B

G) •

e-m

ail:

G&

P@

ma

il.c

sg

-ne

t.it

46

Warranty

Page 48: M2 line DIN - 48 x 48 controller temperature Hot runner · Hot runner temperature controller 1 / 16 DIN - 48 x 48 M2 line c User manual • M.I.U.M2 -2/03.01 • Cod. J30-478-1AM2

47

SUBSIDIARY

FRANCEASCON FRANCE

Phone 0033 1 64 30 62 62Fax 0033 1 64 30 84 98

AGENCE SUD-EST

Phone 0033 4 74 27 82 81Fax 0033 4 74 27 81 71

AGENCE RÉGION-EST

Phone 0033 3 89 76 99 89Fax 0033 3 89 76 87 03

DISTRIBUTORS

ARGENTINAMEDITECNA S.R.L.Phone +5411 4585 7005Fax +5411 4585 3437

AUSTRALIAIPA INDUSTRIAL PYROMETER

(AUST) PTY.LTDPhone +61 8 8352 3688Fax +61 8 8352 2873

FINLAND & ESTONIATIM-TOOL OY

Phone +358 50 501 2000Fax +358 9 50 55 144

GERMANYMESA INDUSTRIE ELEKTRONIK GMBHPhone +49 2365 915 220Fax +49 2365 915 225

GREECECONTROL SYSTEM

Phone +30 23 10 521 055-6 Fax +30 23 10 515 495BRANCH OFFICE

Phone +30 1 646 6276Fax +30 1 646 6862

HOLLANDTEMPCONTROL I.EP. B.V.Phone +31 70 347 64 31Fax +31 70 38 22 55 16

PORTUGALREGIQUIPAMENTOS LDAPhone +351 21 989 0738Fax +351 21 989 0739

SPAININTERBIL S.L.Phone +34 94 453 50 78Fax +34 94 453 51 45

BRANCH OFFICES

Phone +34 93 311 98 11 Fax +34 93 311 93 65 Phone +34 91 656 04 71Fax +34 91 656 04 71

SWITZERLANDCONTROLTHERM GMBHPhone +41 1 954 37 77Fax +41 1 954 37 78

TURKEY KONTROL SISTEMLERI LTDPhone +90 216 527 96 15Fax +90 216 527 96 20

UNITED KINGDOMEUKERO CONTROLS LTDPhone +44 20 8568 4664Fax +44 20 8568 4115

ASCON’S WORLDWIDE SALES NETWORK