8/8/2019 m120 Pic Eol
1/30
M120 Multiservice Edge Router
End-of-Life PIC Guide
August2010
This guide provides an overview and description of the PICs supported by the Juniper
Networks M120Multiservice Edge Router that areend-of-life andcan no longerbe ordered.
Contents M120 PICs Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
M120 End-of-Life PICs Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Adaptive Services II PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Adaptive Services II Layer 2 Services PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . 7
Channelized E1 IQ PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Channelized OC12 IQ PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
DS3 PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Link Services PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SONET/SDH OC3c/STM1 PICs (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SONET/SDH OC12c/STM4 PICs (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . 20SONET/SDH OC48c/STM16 PIC with SFP (M120 Router) . . . . . . . . . . . . . . . . . . . 23
SONET/SDH OC192c/STM64 PIC (M120 Router) . . . . . . . . . . . . . . . . . . . . . . . . . 26
Junos OS Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
1Copyright 2010, Juniper Networks, Inc.
8/8/2019 m120 Pic Eol
2/30
M120 PICs Description
PICs provide the physical connection to various network media types, receiving incoming
packets from the network and transmitting outgoing packets to the network. During this
process, each PIC performs framing and line-speed signaling for its media type. Before
transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the
media type of that PIC. The PICslotsare labeledPIC0,PIC1,PIC2,andPIC3, topto bottom
and left to right.
PICs are hot-removable and hot-insertable. You can install up to four PICs into the slots
ina Type 1 orType 2 FPC orone PIC ina Type 3 FPC. PICsusedin anFPC1 or FPC2have
captive screws attheir upper and lower corners, and PICs used in an FPC3 havean upper
ejector handle and a lower captive screw.
The router supports various PICs,including ATM, Channelized,Gigabit Ethernet, IP Services,
and SONET/SDH interfaces. For a complete list of supported PICs, see M120 PICs
Supported. For a complete listof end-of-life PICs, seeM120 End-of-Life PICs Supported
on page 3.
Blank PICs resemble other PICs but do not provide any physical connection or activity.
When a slot is not occupied bya PIC, you must insert a blank PIC tofill the empty slot
and ensure proper cooling of the system.
Related Topics M120 PICs Supported
M120 PIC/FPC Compatibility
Troubleshooting M120 PICs
Maintaining M120 PICs and PIC Cables
Replacing an M120 PIC
Copyright 2010, Juniper Networks, Inc.2
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
3/30
M120 End-of-LifePICs Supported
Table 1 on page 3 lists the end-of-life PICs supported by the M120 Router. The PICs are
listed alphabetically by PIC family.
Table 1: End-of-LifePICs Supported in theM120 Router
First JunosOS
Release
SupportPortsModelNumberPICFamily andType
Channelized IQ
8.0R210PB-10CHE1-RJ48-QPPChannelized E1 IQPIC(M120Router)onpage 10
8.0R21PB-1CHOC12SMIR-QPPChannelizedOC12 IQPIC(M120Router)onpage 12
DS3
8.0R24PB-2DS3DS3 PIC(M120Router)onpage 14
Services
8.0R20PB-AS2Adaptive Services II PIC(M120Router) onpage 4
8.0R20PB-AS2-LAYER2SERVICESAdaptive Services II Layer2 Services PIC(M120
Router) onpage7
6.10PE-LS-4
PE-LS-32
PE-LS-128
LinkServicesPIC(M120Router)onpage 16
SONET/SDH
8.0R24PB-4OC3-SON-MM
PB-4OC3-SON-SMIR
SONET/SDHOC3c/STM1 PICs(M120Router) on
page 17
SONET/SDHOC12c/STM4PICs(M120Router) on
page 20
8.0R21PB-1OC12-SON-MM
PB-1OC12-SON-SMIR
SONET/SDH OC12c/STM4 PIC
8.0R24PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
SONET/SDH OC12c/STM4 PIC
8.0R21PB-1OC48-SON-SFPSONET/SDHOC48c/STM16PICwithSFP (M120
Router) onpage23
5.41PC-1OC192-SON-LR
PC-1OC192-SON-SR2
SONET/SDHOC192c/STM64PIC(M120Router) on
page 26
Related Topics M120 PICs Description on page 2
3Copyright 2010, Juniper Networks, Inc.
M120End-of-Life PICs Supported
8/8/2019 m120 Pic Eol
4/30
Adaptive Services II PIC(M120 Router)
Junos OS Release 8.0R2and later
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
Supportstunnel services.This featureis includedwith thePIC and doesnot requirean individual
license.
Individual licenses must be purchased foradditional services.
Power requirement: 0.4 A @ 48 V (19 W)
Description
Support for up to 2000 service sets
Active monitoring on up to 1 million flows
Support for MTUs up to 9192 bytes forGigabit Ethernet and SONET interfaces
Hardware features
Depending on your Junos OS Release and individual licenses, software features for this PIC can
include the features listed in Table2 on page5. Formore information about thesoftwarefeatures
available for services PICs, see theJunos Services Interfaces Configuration Guide.
Software features
Status LED, one tricolor:
OffPIC is offline andit is safe toremove it from the chassis.
GreenPIC is operating normally.
YellowPIC is initializing.
RedPIChas anerroror failureand nofurtherharmcan bedoneby removingit from thechassis.
Application LED, one bicolor:
OffService is not running.
GreenService is running under acceptable load.
YellowService is overloaded.
LEDs
Copyright 2010, Juniper Networks, Inc.4
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
5/30
Table 2: Adaptive Services PICs SoftwareFeatures Supported by theM120Router
AdaptiveServices
II Layer 2 ServicesPIC
Adaptive Services IIPICSoftware Feature
GRE Key
GRE dont-fragment
8.0R2Stateful firewall with packet inspection: detects
SYN attacks, ICMP and UDP floods, and
ping-of-death attacks
8.0R2Network Address Translation (NAT) for IP
addresses
8.0R2PortAddress Translation(PAT) forport numbers
8.0R2IP Security (IPSec) encryption
8.0R2Active flow monitoring exports cflowd version 5
and version 8 records
8.3Active flow monitoring exports flow monitoring
version 9 records, based on RFC 3954 (IPv4
templates only)
Passive flow monitoring
Passive flow collection
Flow-tap
Dynamic flow capture
8.3Real-time performance monitoring
8.0R28.0R2Link services
8.0R28.0R2Tunnel services:
IP-IP unicast tunneling
GRE unicast tunnelingSupports GRE
fragmentation
Protocol Independent Multicast (PIM) sparse
mode unicast tunneling
8.0R2Virtual tunnel interface for Layer 3 VPNs
8.0R28.0R2Layer 2 Tunneling Protocol (L2TP)
5Copyright 2010, Juniper Networks, Inc.
Adaptive Services II PIC (M120 Router)
8/8/2019 m120 Pic Eol
6/30
Table 2: Adaptive Services PICs SoftwareFeatures Supported by theM120Router (continued)
AdaptiveServices
II Layer 2 ServicesPIC
Adaptive Services IIPICSoftware Feature
8.0R28.0R2Voice services:
Compressed Real-Time Transport Protocol
(CRTP)
8.0R2Encapsulations:
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
Copyright 2010, Juniper Networks, Inc.6
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
7/30
Adaptive Services II Layer 2 ServicesPIC(M120 Router)
Junos OS Release 8.0R2and later (Type 1)
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
SupportsLayer 2 Servicepackageonly.Tunnel servicesare includedwith the PIC.Other services
require an individual license.
Power requirement: 0.4 A @ 48 V (19 W)
Description
Support for up to 2000 service sets
Support for MTUs up to 9192 bytes forGigabit Ethernet and SONET interfaces
Hardware features
Depending on your Junos OS Release and individual licenses, software features for this PIC can
include the features listed in Table3 onpage 8. Formore information about thesoftwarefeatures
available for services PICs, see theJunos Services Interfaces Configuration Guide.
Software features
Status LED, one tricolor:
OffPIC is offline andit is safe toremove it from the chassis.
GreenPIC is operating normally.
YellowPIC is initializing.
RedPIChas anerroror failureand nofurtherharmcan bedoneby removingit from thechassis.
Application LED, one bicolor:
OffService is not running.
GreenService is running under acceptable load.
YellowService is overloaded.
LEDs
7Copyright 2010, Juniper Networks, Inc.
Adaptive Services II Layer 2 Services PIC (M120 Router)
8/8/2019 m120 Pic Eol
8/30
Table 3: Adaptive Services PICs SoftwareFeatures
AdaptiveServices
II Layer 2 Services
PIC
Adaptive Services II
PICSoftware Feature
GRE Key
GRE dont-fragment
8.0R2Stateful firewall with packet inspection: detects
SYN attacks, ICMP and UDP floods, and
ping-of-death attacks
8.0R2Network Address Translation (NAT) for IP
addresses
8.0R2PortAddress Translation(PAT) forport numbers
8.0R2IP Security (IPSec) encryption
8.0R2Active flow monitoring exports cflowd version 5
and version 8 records
8.3Active flow monitoring exports flow monitoring
version 9 records, based on RFC 3954 (IPv4
templates only)
Passive flow monitoring
Passive flow collection
Flow-tap
Dynamic flow capture
8.3Real-time performance monitoring
8.0R28.0R2Link services
8.0R28.0R2Tunnel services:
IP-IP unicast tunneling
GRE unicast tunnelingSupports GRE
fragmentation
Protocol Independent Multicast (PIM) sparse
mode unicast tunneling
8.0R2Virtual tunnel interface for Layer 3 VPNs
8.0R28.0R2Layer 2 Tunneling Protocol (L2TP)
Copyright 2010, Juniper Networks, Inc.8
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
9/30
Table 3: Adaptive Services PICs SoftwareFeatures (continued)
AdaptiveServices
II Layer 2 Services
PIC
Adaptive Services II
PICSoftware Feature
8.0R28.0R2Voice services:
Compressed Real-Time Transport Protocol
(CRTP)
8.0R2Encapsulations:
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
9Copyright 2010, Juniper Networks, Inc.
Adaptive Services II Layer 2 Services PIC (M120 Router)
8/8/2019 m120 Pic Eol
10/30
ChannelizedE1 IQPIC (M120 Router)
Junos OS Release 8.0R2and later
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
Ten E1 ports
Power requirement: 0.15 A @ 48 V (7.2 W)
Fine-grained queuing per logical interface.
Channelization: E1, DS0
Description
Data service unit (DSU) functionality
Ports configurable as clear channel E1 interfaces with 2.048-Mbps connectivity Supports unframed E1 G.703 and G.704 framing modes
Supports HDB3 line coding
CRC4 configurable
Local and remote loopback testing
Hardware features
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
SimpleNetwork Management Protocol (SNMP): E1 MIB, DS0 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
120-ohm RJ-48CCablesand connectors
Copyright 2010, Juniper Networks, Inc.10
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
11/30
One bicolor per E1 port:
OffPort not enabled
GreenPhysical E1 link is up; individual subchannels can be down
RedPhysical E1 link is down
LEDs
Alarm indication signal (AIS)
Loss of frame (LOF)
Out of frame (OOF)
Failed signal rate (FSR)
Alarms, errors, and
events
Layer 2 per-queue and per-channel packet and byte countersInstrumentation
(counters)
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
11Copyright 2010, Juniper Networks, Inc.
ChannelizedE1 IQ PIC (M120 Router)
8/8/2019 m120 Pic Eol
12/30
ChannelizedOC12 IQPIC(M120 Router)
Junos OS Release 8.0R2and later (Type 1)
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
OneOC12port
Power requirement: 0.23 A @ 48 V (10.8 W)
Fine-grained queuing per logical interface
Channelization: OC3, DS3, DS1, DS0
Description
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local and remote loopback testing
Hardware features
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
SimpleNetwork Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
Copyright 2010, Juniper Networks, Inc.12
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
13/30
Duplex SC/PC connector (Rx and Tx); single-mode fiber
SONET/SDH OC12/STM4 fixed transceivers:
Intermediate reach (IR-1)
Optical interfacespecificationssee SONET/SDH OC12/STM4Optical InterfaceSpecifications
Cablesand connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end
block error (FEBE), far-end erroredseconds(ES-LFE, ES-PFE),far-endseverelyerrored seconds
(SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Frame error
Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored
seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Yellow alarm bit (X-bit) disagreements
Alarms, errors, and
events
Layer 2 per-queue and per-channel packet and byte countersInstrumentation
(counters)
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
13Copyright 2010, Juniper Networks, Inc.
Channelized OC12IQ PIC (M120 Router)
8/8/2019 m120 Pic Eol
14/30
DS3 PIC(M120 Router)
Junos OS Release 8.0R2and later (Type 1)
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
Four DS3 ports
Power requirement: 0.47A @ 48 V (22.5 W)
Integrated DSU interoperability with leading DSU vendors
Description
High-performance throughput on each port at speeds up to 44.736 Mbps, full duplex
C-bit framing
B3ZS line encoding
Subrate and scrambling:
Digital Link
Kentrox
Larscom
Per-port rate policing on input
Per-port rate shaping on output
Packet buffering, Layer 2 parsing
Hardware features
DS3 functionality:
C-bit framing
B3ZS line encoding
DS3 diagnostics and loopback control
DS3 alarm and event counting and detection
Per-packet counts and byte counts Local and remote loopback testing, as well as BERT testing per DS3
DS3 far-end alarm and control (FEAC) channel support
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Software features
Copyright 2010, Juniper Networks, Inc.14
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
15/30
Custom 10-ft (3.05-m) posilock SMB to BNC male cable, separate Rx and Tx (provided)Cablesand connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
Alarm indication signal (AIS)
Bit error rate test (BERT) functionality on PIC (you can configure one DS3 channel in BERT
mode and configure the remaining channels to transmit and receive normal traffic)
Equipment failure (does not affect service)
Far-end block error (FEBE)
Frame error
Idle code, Idle received
Local and remote loopback Loss of signal (LOS)
Out of frame (OOF)
Parity bit (P-bit) disagreements
Path parity error
Yellow alarm bit (X-bit) disagreements
Alarms, errors, and
events
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
15Copyright 2010, Juniper Networks, Inc.
DS3 PIC (M120 Router)
8/8/2019 m120 Pic Eol
16/30
LinkServicesPIC(M120 Router)
Junos OS Release 6.0 and laterSoftware release
Power requirement: 0.17A @ 48 V (8 W)
Three versions:
4 multilink bundles, 256 LFI links
32 multilink bundles, 256 LFI links
128multilink bundles, 256 LFI links
Multilink bonding, link fragmentation and interleaving (LFI), and tunneling
Description
Rate limiting/policing per multilink bundle
Byte-wise load balancing across multilink bundles
Bonding T1 links enable service ranging from 1.5 Mbps through 12 Mbps
Bonding E1 links enable service ranging from 2 Mbps through 16 Mbps
Loopback function that encapsulates and de-encapsulates packets
Hardware features
For a list of the software features available for services PICs, see theJunos Services Interfaces
Configuration Guide.
Protocol support:
Multilink PPP (MLPPP)
Multilink Frame Relay (MLFR)FRF.15 and FRF.16
Link fragmentation and interleaving (LFI)FRF.12
LFI over MLPPP
IP-IP unicast tunneling
GRE unicast tunneling
PIM sparse mode unicast tunneling
Software features
One bicolor:
OffPIC is offline
GreenPIC is online and at least one configured bundle is operating
YellowPIC is online, but no configured bundles are operating
LEDs
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
Copyright 2010, Juniper Networks, Inc.16
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
17/30
SONET/SDHOC3c/STM1PICs (M120Router)
Figure2: 4-PortSONET/SDHOC3c/STM1 PIC(SMF-IR)
STATUS
ONLINE/OFFLINE
STM-1/OC-3SONET SMF-IR
STATUS
RX
TX
TX
RX
PO
RT
1
PO
RT
3
PO
RT
2
PO
RT
0
g
00
23
79
Figure 1: 4-PortSONET/SDHOC3c/STM1 PIC(MMF)
Junos OS Release 8.0R2and later (Type 1) multimode and single-mode intermediate reach
NOTE: These PICs are not supported in Junos OS Release 8.1R1.
Software release
Four OC3 ports
Power requirement: 0.49 A @ 48 V (23.7 W)
Description
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Hardware features
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
17Copyright 2010, Juniper Networks, Inc.
SONET/SDH OC3c/STM1 PICs (M120 Router)
8/8/2019 m120 Pic Eol
18/30
Duplex SC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 fixed transceivers:
Multimode
Intermediate reach (IR-1) (model number: SFP-OC3-IR)Optical interface specificationssee SONET/SDH OC3/STM1 Optical Interface Specifications
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links,
take thePIC offline until youare ready toestablish a linkto another device. For information about
taking a PIC offline, see the request chassis pic offlinecommand in theJunos System Basics and
Services Command Reference.
Cablesand connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
Copyright 2010, Juniper Networks, Inc.18
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
19/30
SONET alarms:
Alarm indication signalline (AIS-L)
Alarm indication signalpath (AIS-P)
Bit error rate signal degrade (BERR-SD) Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indicationline (REI-L) (CV-LFE)
Far-end bit error: remote error indicationpath (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indicationline (RDI-L) Remote defect indicationpath (RDI-P)
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
Erroredseconds(ES-S,ES-L, ES-P), far-enderrored seconds(ES-LFE, ES-PFE),far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored
seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Alarms, errors, and
events
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
SONET/SDH OC3/STM1 Optical Interface Specifications
19Copyright 2010, Juniper Networks, Inc.
SONET/SDH OC3c/STM1 PICs (M120 Router)
8/8/2019 m120 Pic Eol
20/30
SONET/SDHOC12c/STM4PICs (M120 Router)
Figure4: 4-PortSONET/SDHOC12c/STM4PIC
Figure3: 1-PortSONET/SDHOC12c/STM4PIC
Junos OS Release 8.0R2and later
NOTE: These PICs are not supported in Junos OS Release 8.1R1.
Software release
Oneor four ports
Power requirement: 0.23 A @ 48 V (10.8 W)
Description
Multiplexing and demultiplexing Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Hardware features
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
Copyright 2010, Juniper Networks, Inc.20
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
21/30
Duplex SC/PC connector (Rx and Tx)
SONET/SDH OC12/STM4 fixed transceivers:
Multimode
Intermediate reach (IR-1)Optical interfacespecificationssee SONET/SDH OC12/STM4Optical InterfaceSpecifications
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links,
take thePIC offline until youare ready toestablish a linkto another device. For information about
taking a PIC offline, see the request chassis pic offlinecommand in theJunos System Basics and
Services Command Reference.
Cablesand connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
21Copyright 2010, Juniper Networks, Inc.
SONET/SDH OC12c/STM4 PICs (M120 Router)
8/8/2019 m120 Pic Eol
22/30
SONET alarms:
Alarm indication signalline (AIS-L)
Alarm indication signalpath (AIS-P)
Bit error rate signal degrade (BERR-SD) Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indicationline (REI-L) (CV-LFE)
Far-end bit error: remote error indicationpath (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indicationline (RDI-L) Remote defect indicationpath (RDI-P)
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
Erroredseconds(ES-S,ES-L, ES-P), far-enderrored seconds(ES-LFE, ES-PFE),far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored
seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Alarms, errors, and
events
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
SONET/SDH OC12/STM4 Optical Interface Specifications
Copyright 2010, Juniper Networks, Inc.22
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
23/30
SONET/SDHOC48c/STM16PICwithSFP(M120Router)
Junos OS Release 8.0R2and later
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
Software release
OneOC48port
Power requirement: 0.33 A @ 48 V (16 W)
Description
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Hardware features
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
23Copyright 2010, Juniper Networks, Inc.
SONET/SDHOC48c/STM16 PIC withSFP (M120 Router)
8/8/2019 m120 Pic Eol
24/30
Duplex LC/PC Connector (Rx and Tx)
SONET/SDH OC48/STM16 small form-factor pluggable (SFP) transceivers:
Short reach (SR-1) (model number: SFP-1OC48-SR)
Intermediate reach (IR-1) (model number: SFP-1OC48-IR) Long reach (LR-1) (model number: SFP-1OC48-LR)
OpticalinterfacespecificationsseeSONET/SDHOC48/STM16 OpticalInterfaceSpecifications
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links,
take thePIC offline until youare ready toestablish a linkto another device. For information about
taking a PIC offline, see the request chassis pic offlinecommand in theJunos System Basics and
Services Command Reference.
Cablesand connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
Copyright 2010, Juniper Networks, Inc.24
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
25/30
SONET alarms:
Alarm indication signalline (AIS-L)
Alarm indication signalpath (AIS-P)
Bit error rate signal degrade (BERR-SD) Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indicationline (REI-L) (CV-LFE)
Far-end bit error: remote error indicationpath (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indicationline (RDI-L) Remote defect indicationpath (RDI-P)
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
Erroredseconds(ES-S,ES-L, ES-P), far-enderrored seconds(ES-LFE, ES-PFE),far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored
seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Alarms, errors, and
events
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
SONET/SDH OC48/STM16 Optical Interface Specifications
25Copyright 2010, Juniper Networks, Inc.
SONET/SDHOC48c/STM16 PIC withSFP (M120 Router)
8/8/2019 m120 Pic Eol
26/30
SONET/SDHOC192c/STM64 PIC (M120Router)
Junos OS Release 5.4 and later (Type 3)Software release
One OC192 port
Power requirement: 0.45 A @ 48 V (21.6 W)
Description
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Hardware features
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
SONET/SDH OC192c/STM64 fixed transceivers:
Short reach (SR-2): duplex SC/PC connector (Rx and Tx)
Long reach (LR-1): duplex SC/PC connector (Rx and Tx)
Optical interface supportSeeSONET/SDHOC192c/STM64Fixed TransceiverOptical Interface
Specifications
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links,
take thePIC offline until youare ready toestablish a linkto another device. For information about
taking a PIC offline, see the request chassis pic offlinecommand in theJunos System Basics and
Services Command Reference.
Cablesand connectors
Copyright 2010, Juniper Networks, Inc.26
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
27/30
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
YellowOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
SONET alarms:
Alarm indication signalline (AIS-L)
Alarm indication signalpath (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indicationline (REI-L) (CV-LFE)
Far-end bit error: remote error indicationpath (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indicationline (RDI-L)
Remote defect indicationpath (RDI-P)
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
Erroredseconds(ES-S,ES-L, ES-P), far-enderrored seconds(ES-LFE, ES-PFE),far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored
seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Alarms, errors, and
events
Related Topics M120 PICs Description on page 2
M120 End-of-Life PICs Supported on page 3
27Copyright 2010, Juniper Networks, Inc.
SONET/SDH OC192c/STM64 PIC (M120 Router)
8/8/2019 m120 Pic Eol
28/30
SONET/SDH OC192c/STM64 Fixed Transceiver Optical Interface Specifications
Copyright 2010, Juniper Networks, Inc.28
M120 Multiservice Edge Router End-of-Life PIC Guide
8/8/2019 m120 Pic Eol
29/30
JunosOSDocumentationandReleaseNotes
For a list of related Junos OS documentation, see
http://www.juniper.net/techpubs/software/junos/ .
If the information in the latest release notes differs from the information in the
documentation, follow theJunos OS Release Notes.
To obtain the most current version of all Juniper Networks
technical documentation,
see the product documentation page on the Juniper Networks website at
http://www.juniper.net/techpubs/.
RequestingTechnical Support
Technical productsupportis available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or JNASC support contract,
or are covered under warranty, and need post-sales technical support, you can access
our tools and resources online or open a case with JTAC.
JTAC policiesFor a complete understanding of our JTAC procedures and policies,
review the JTAC User Guide located at
http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf .
Product warrantiesFor product warranty information, visit
http://www.juniper.net/support/warranty/ .
JTAC hours of operationThe JTAC centers have resources available 24 hours a day,
7 daysa week, 365 days a year.
Self-HelpOnline Tools andResources
For quick and easy problem resolution, Juniper Networks has designed an online
self-service portal called the Customer Support Center (CSC) that provides you with the
following features:
Find CSC offerings: http://www.juniper.net/customers/support/
Search for known bugs: http://www2.juniper.net/kb/
Find product documentation:http://www.juniper.net/techpubs/
Find solutions and answer questions using our Knowledge Base:http://kb.juniper.net/
Download the latest versions of software and review release notes:
http://www.juniper.net/customers/csc/software/
Search technical bulletins for relevant hardware and software notifications:
https://www.juniper.net/alerts/
Join and participate in the Juniper Networks Community Forum:
http://www.juniper.net/company/communities/
Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
29Copyright 2010, Juniper Networks, Inc.
Junos OS Documentation and Release Notes
http://www.juniper.net/techpubs/software/junos/http://www.juniper.net/techpubs/http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdfhttp://www.juniper.net/support/warranty/http://www.juniper.net/customers/support/http://www2.juniper.net/kb/http://www.juniper.net/techpubs/http://kb.juniper.net/http://www.juniper.net/customers/csc/software/https://www.juniper.net/alerts/http://www.juniper.net/company/communities/http://www.juniper.net/cm/http://www.juniper.net/cm/http://www.juniper.net/company/communities/https://www.juniper.net/alerts/http://www.juniper.net/customers/csc/software/http://kb.juniper.net/http://www.juniper.net/techpubs/http://www2.juniper.net/kb/http://www.juniper.net/customers/support/http://www.juniper.net/support/warranty/http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdfhttp://www.juniper.net/techpubs/http://www.juniper.net/techpubs/software/junos/8/8/2019 m120 Pic Eol
30/30
To verify service entitlementby productserial number, use our Serial NumberEntitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Casewith JTAC
You can open a case with JTAC on the Web or by telephone.
Use the Case Management tool in the CSC athttp://www.juniper.net/cm/.
Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see
http://www.juniper.net/support/requesting-support.html .
RevisionHistory
August 2010Corporate rebranding.
May 2010Added Channelized OC12 IQ 1-port and DS3 4-port PICs.
January 2010Added bulleted list and model numbers to the PICs Supported table.
10 2009530-022465-01.Revision 4. Added Channelized E1 IQ PIC. Added related topics
for easier customer navigation.
28 July 2008530-022465-01. Revision 3. Added Adaptive Services II PIC. Added
SONET/SDH OC3 and OC12 PICs.
1 February 2008530-022465-01. Revision 2. Added SONET/SDH OC3c/STM1 PIC
(SMF-IR),SONET/SDHOC12c/STM4 PIC (SMF-IR),SONET/SDHOC12c/STM4 PIC (MM),
and SONET/SDH OC48c/STM16 PIC with SFP.
12 October 2007530-022465-01. Revision 1. Added SONET/SDH OC192c/STM64 PIC
(PC-1OC192-SON-SR2).
29 June 2007530-021483-01. Revision 1.
Copyright 2010, Juniper Networks, Inc.All rights reserved.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc.in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc.All othertrademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,
transfer, or otherwise revise this publication without notice.
Products made or sold byJuniper Networks or components thereof might be covered by oneor more of thefollowing patents that are
owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440,6,192,051, 6,333,650, 6,359,479, 6,406,312,
6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
M120 Multiservice Edge Router End-of-Life PIC Guide
https://tools.juniper.net/SerialNumberEntitlementSearch/http://www.juniper.net/cm/http://www.juniper.net/support/requesting-support.htmlhttp://www.juniper.net/support/requesting-support.htmlhttp://www.juniper.net/cm/https://tools.juniper.net/SerialNumberEntitlementSearch/