    RemoteMonitoring Module

    M-3904B

    PROTECTIVE

    RELAYS

    Provides monitoring of the M-3425A IntegratedProtection System

    Relays

    Solves Relay Panel Mounting Space Problems

    Can be used to provide access to relay information

    in remote Control Rooms 2 by 20 Character Backlit Liquid Crystal Display (LCD)

    User-Friendly Menu System

  • 8/10/2019 M-3904B-SP.pdf

    2/10

  • 8/10/2019 M-3904B-SP.pdf

    3/10

  • 8/10/2019 M-3904B-SP.pdf

    4/10

    4

    M-3904B Remote Monitor Module

    B-1268 Cable Connector KitEach unit includes a 25 foot B-1268 Cable and Connector Kit. The Remote Monitor Module can interface with theprotection relay through either the RS-232 or RS-485 port on the relay. Cable orientation and pin assignments areillustrated in Figure 2. The relay Com Port must be configured to util ize the MODBUS protocol and have the CommDelay setting for COM2 set to zero.

    RJ-45

    1 8

    RJ-45

    654

    RXDTXDRETURN

    3 CTS21

    TXD-TXD+

    87

    RXD+RXD-

    Rear Terminal Block

    of the M-3425A

    325

    RS-232 RJ45 RS-232RJ45(FEMALE)

    281

    281

    TXD-RXD+TXD+

    77RXD-

    (MALE)

    281

    7TXD-RXD+TXD+

    RXD-

    6 RXD

    5 TXD4 RETURN

    YELLOW

    GREENRED

    ORANGEWHITEBLUE

    BROWNGREENBLACKRED

    WHITE

    [RS-485][RS-232]

    TXD-

    RXD+ TXD+

    RXD-

    Figure 2 B-1268 Universal Connecting Cable

  • 8/10/2019 M-3904B-SP.pdf

    5/10

    5

    M-3904B Remote Monitor Module

    External ConnectionsM-3904B external connection points are illustrated in Figure 3.

    REAR VIEW

    CL

    SIDE VIEW

    4.00

    [101.2]

    6.00 [152.4]

    FRONT VIEW

    [40.6]

    1.60

    3.00 [76.2] 0.16[4.1]

    [44.7]

    1.76

    shown for ref.plug & cableShielded RJ-45

    Maximum depth

    behind the FRONTof any panel

    1.50[38.1]Ground lug &

    power cableshown for ref.

    Shielded

    green wire to ground

    (Panel)

    6-32UNC stud,

    BOTTOM VIEW

    4 places

    1.46 [37]

    Dimensions are in inches [mm].

    1 2 TARGETRESET

    M-3904B

    Figure 3 Remote Monitor Module Overall Dimensions

  • 8/10/2019 M-3904B-SP.pdf

    6/10

    6

    M-3904B Remote Monitor Module

    3.50 0.01

    [88.9 0.3]

    3.70 0.03

    [94.0 0.8]

    5.10 0.030

    [129.5 0.8

    5.60 0.01

    [142.2 0.3]

    0.172 0.01 [4.4 0.3]

    diameter, 4 holes

    R 0.08 [2.0mm] maximum,

    4 places

    Connect Mounting Stud(s) toControl Panel Earth Ground.

    NOTES:

    1. Dimensions are in inches [mm].

    2. Holes are symmetrically located on the center of the cutout.

    3. Maximum panel thickness is 0.125 [3.2mm].

    4. Minimum panel thickness is 0.029 [1.5mm].

    Figure 4 Cutout Dimensions

    Power Supply Requirements

    +12 to +30 V dc (24 V dc 1.2A dedicated Linear Power Supply recommended)

    Consumption 2.5 Watts typical, 3 Watts maximum

  • 8/10/2019 M-3904B-SP.pdf

    7/10

    7

    M-3904B Remote Monitor Module

    PhysicalSize: 6.0 wide x 4.0 high x 1.77 deep (15.24 cm x 10.16 cm x 4.5 cm)

    Mounting: Flush-mounted, by 4 pressure-type fasteners on a 0.059 to 0.125 (1.5 to 3.2 mm) thick panel. Panelcutout dimensions are shown in Figure 4.

    Approximate Weight: 1 lbs (0.45 kg)

    Patent & Warranty

    The M-3904B Remote Monitor Module is covered by an 18 month warranty from date of shipment.

    For additional information, please refer to the included Maple Systems, Inc. OIT 3165 data sheet No. 0901-0061,Rev. 00 (05/09).

    Specification subject to change without notice.