44
Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2020 Murata LTE-M EVK User Guide, 5/4/2020 Page 1 of 44 www.murata.com Revision History Revision Date Change Description 1.0 01/31/2020 Initial version for new Type1SC/Type1WG EVB with printed antenna 1.1 02/26/2020 Minor updates including email contact 1.2 4/7/2020 Fixed ToC error Type1SC/Type1WG Type1SC-DM EVK User Guide LTE CAT-M1 / NB-IoT EVK

LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2020

Murata LTE-M EVK User Guide, 5/4/2020 Page 1 of 44 www.murata.com

Revision History Revision Date Change Description

1.0 01/31/2020 Initial version for new Type1SC/Type1WG EVB with printed antenna

1.1 02/26/2020 Minor updates including email contact

1.2 4/7/2020 Fixed ToC error

Type1SC/Type1WG Type1SC-DM

EVK User Guide

LTE CAT-M1 / NB-IoT EVK

Page 2: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2020

Murata LTE-M EVK User Guide, 5/4/2020 Page 2 of 44 www.murata.com

Table of Contents

REVISION HISTORY .............................................................................................................................................................. 1

TABLE OF CONTENTS ......................................................................................................................................................... 2

1 INTRODUCTION ............................................................................................................................................................ 5

1.1 Scope ......................................................................................................................................................................... 5 1.2 Audience .................................................................................................................................................................... 6 1.3 Contact Info and Support ........................................................................................................................................... 6 1.4 Text Conventions ....................................................................................................................................................... 6 1.5 Kit Contents ................................................................................................................................................................ 6

2 DESCRIPTION ............................................................................................................................................................... 7

3 POWER SUPPLY ........................................................................................................................................................... 9

3.1 USB power supply ...................................................................................................................................................... 9 3.2 External 5V supply ................................................................................................................................................... 10

4 SERIAL INTERFACES ................................................................................................................................................ 10

5 INDICATION AND SERVICES .................................................................................................................................... 11

5.1 Optical Indicators ..................................................................................................................................................... 11 5.1.1 LED1: PMU_EXT_ALARM status ................................................................................................................... 11 5.1.2 LED2: PWM3 status ........................................................................................................................................ 11 5.1.3 LED3: SMA / ANT select status ...................................................................................................................... 11

5.2 Services.................................................................................................................................................................... 11 5.2.1 Reset operation ............................................................................................................................................... 12 5.2.2 Recovery operation ......................................................................................................................................... 12 5.2.3 Wakeup operation ........................................................................................................................................... 12 5.2.4 Reserved operation ......................................................................................................................................... 12

6 MODULE IO INTERFACE............................................................................................................................................ 12

6.1 Arduino interface ...................................................................................................................................................... 12 6.2 Expansion headers .................................................................................................................................................. 13

7 STARTUP PROCEDURE............................................................................................................................................. 15

7.1 Install PuTTY ............................................................................................................................................................ 15 7.2 Connection to PC ..................................................................................................................................................... 15 7.3 AT/PPP port ............................................................................................................................................................. 16

7.3.1 AT commands ................................................................................................................................................. 17 7.3.2 From AT Channel to PPP Channel ................................................................................................................. 17

7.4 CLI port ..................................................................................................................................................................... 17 7.4.1 CLI commands ................................................................................................................................................ 18 7.4.2 Sending AT commands from CLI channel ...................................................................................................... 19 7.4.3 From CLI Channel to AT Channel ................................................................................................................... 19

8 PPP LTE CONNECTION – WINDOWS ....................................................................................................................... 19

8.1 Creating a modem .................................................................................................................................................... 20 8.2 Creating PPP connection entry ................................................................................................................................ 23 8.3 Establishing the LTE connection .............................................................................................................................. 27 8.4 Making the PPP connection ..................................................................................................................................... 28

9 CURRENT MEASUREMENT ....................................................................................................................................... 32

10 FIRMWARE UPGRADE ............................................................................................................................................... 33

11 EVK SCHEMATICS ..................................................................................................................................................... 34

Page 3: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 3 of 44 www.murata.com

12 SAFETY RECOMMENDATIONS ................................................................................................................................. 43

12.1 Disposal of this product in the European Union ....................................................................................................... 43 12.2 Disposal of this product in other countries outside the European Union ................................................................. 43

13 ACRONYMS ................................................................................................................................................................. 44

Page 4: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 4 of 44 www.murata.com

LIST OF FIGURES Figure 1 Evaluation Board with Type1SC (top) and Type1WG (bottom) ................................................................................ 5 Figure 2 Murata LTE module development kit contents ......................................................................................................... 6 Figure 3 Murata LTE module evaluation board (top view) ...................................................................................................... 7 Figure 4 Murata LTE module evaluation board (bottom view) ................................................................................................ 8 Figure 5 Power supply block diagram ..................................................................................................................................... 9 Figure 6 USB connectors location........................................................................................................................................... 9 Figure 7 Ext_Vin pin location on bottom side of EVB ........................................................................................................... 10 Figure 8 Exported UART interfaces ...................................................................................................................................... 10 Figure 9 LED locations on EVB............................................................................................................................................. 11 Figure 10 Button locations on EVB ....................................................................................................................................... 11 Figure 11 EVK setup ............................................................................................................................................................. 15 Figure 12 COM ports assignment shown in Device Manger ................................................................................................ 16 Figure 13 PuTTY configuration for AT port ........................................................................................................................... 16 Figure 14 PuTTY configuration for CLI port .......................................................................................................................... 18 Figure 15 Prompt for CLI Port ............................................................................................................................................... 18 Figure 16 CLI Commands ..................................................................................................................................................... 19 Figure 17 Modems Tab ......................................................................................................................................................... 20 Figure 18 ‘Add New Hardware Wizard’ ................................................................................................................................. 20 Figure 19 Next Screen .......................................................................................................................................................... 21 Figure 20 Modem Selection .................................................................................................................................................. 21 Figure 21 Click Selected Ports .............................................................................................................................................. 22 Figure 22 Modems Installed .................................................................................................................................................. 22 Figure 23 Set the Baud Rate ................................................................................................................................................. 23 Figure 24 Accessing dial-up connection ............................................................................................................................... 24 Figure 25 Creating Dial-up Connection ................................................................................................................................. 24 Figure 26 Connection is Ready ............................................................................................................................................. 25 Figure 27 Set Connection Anyway ........................................................................................................................................ 25 Figure 28 Access for Change Adapter Settings .................................................................................................................... 26 Figure 29 Change Adapter Settings ...................................................................................................................................... 26 Figure 30 PPP Properties ..................................................................................................................................................... 27 Figure 31 CLI Console .......................................................................................................................................................... 28 Figure 32Enabling hardware control ..................................................................................................................................... 28 Figure 33 PPP Connection – Network Connections Panel ................................................................................................... 29 Figure 34 Windows 10 Pop-Up Screen ................................................................................................................................. 29 Figure 35: Click “PPP” ........................................................................................................................................................... 30 Figure 36 Connect “PPP” ...................................................................................................................................................... 30 Figure 37 Options .................................................................................................................................................................. 31 Figure 38 PPP Connection .................................................................................................................................................... 31 Figure 39 PPP Connection .................................................................................................................................................... 32 Figure 40 Power supply setup with Keysight power module ................................................................................................ 33 Figure 41 Image Burn Tool configuration .............................................................................................................................. 34

LIST OF TABLES Table 1 Default CN11 connections ......................................................................................................................................... 8 Table 2 EVB dimensions ......................................................................................................................................................... 9 Table 3 Arduino shield headers: CN3 (power) + CN4 (analog) ............................................................................................ 13 Table 4 Arduino shield headers: CN10 (D8-D15) + CN9 (D0-D7) ........................................................................................ 13 Table 5 Expansion headers pinout: CN3 + CN4 ................................................................................................................... 14 Table 6 Expansion headers pinout: CN10 + CN9 ................................................................................................................. 14

Page 5: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 5 of 44 www.murata.com

1 INTRODUCTION

1.1 Scope

This document provides the general operation instructions for the Murata Cat-M1/NB-IoT Evaluation Kit (EVK) based on the evaluation board with printed antenna and headers CN3, 4, 9, 10, 11 installed, as shown below. Please ensure that the board is the correct version prior to using this document. In the ensuing discussion, Murata LTE module refers to the module mounted on the evaluation board, so it could be either Type1SC or Type1WG.

Figure 1 Evaluation Board with Type1SC (top) and Type1WG (bottom)

CN11

CN3

CN4

CN10

CN9

Type1SC

Type1WG

Page 6: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 6 of 44 www.murata.com

1.2 Audience

This document is intended for software/firmware, hardware and systems engineers to evaluate and develop applications with Murata’s Type1SC and Type1WG LTE Cat M1/NB-IoT modules.

1.3 Contact Info and Support

For general contact, technical support services, technical questions and report documentation errors contact Murata Technical Support at: [email protected].

1.4 Text Conventions

Danger – This information MUST be followed or catastrophic equipment failure or bodily injury may occur. Caution/Warning Alerts the user to important points about using the EVK; if these points are not followed, the EVK and end user equipment may fail or malfunction. Tip/Information – Provides advice and suggestions that may be useful when using the EVK.

1.5 Kit Contents

The Murata LTE module EVK package contains the following items:

• 1 Type1SC (or Tye1WG) Evaluation Board (EVB)

• 2 mini-USB cables

Figure 2 Murata LTE module development kit contents

Page 7: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 7 of 44 www.murata.com

2 DESCRIPTION The EVK is an evaluation and application development kit for the Murata Type1SC and Type1WG LTE modules. It includes an Evaluation Board (EVB) with an Arduino shield interface which allows the EVB to be used across various Arduino based MCU development platforms such as the STM32 Nucleo-64 boards. Some major components of the EVB are listed and shown below.

• Type1SC (or Type1WG) module

• 2 mini-USB ports

• LTE/GNSS antenna

• 1 micro SIM slot

• 3 LEDs

• 4 buttons

• SMA connector for RF testing

• Pads for accessing Murata LTE module IO pins o Arduino headers supporting 3.3V/5V IOs for UART modem control interface o Expansion headers for access to the module pins o Jumpers CN11 to facilitate current measurements

Figure 3 Murata LTE module evaluation board (top view)

Murata LTE module

SMA

CN11 uSIM

socket

Antenna

USB/UARTs

Page 8: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 8 of 44 www.murata.com

Figure 4 Murata LTE module evaluation board (bottom view)

The default CN11 jumper settings are shown below:

Jumper connection Description

Top Bottom

20 1 Connect LDO_EN to 4V3_SUPP

19 2 Connect VBAT_FEM to VBAT_FEM_LDO

18 3 Connect VBAT to Vsys

15 6 Connect ANT_SEL to GND – select SMA path

Table 1 Default CN11 connections

The nominal EVB physical dimensions are as shown below.

VB

AT

_F

EM

Arduino Header

Expansion Header

CN11 pin 1

CN3

CN4

CN10

CN9 L

DO

_E

N

VB

AT

AN

T_

SE

L

Page 9: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 9 of 44 www.murata.com

Dimension Value (mm)

Description

Height 19 EVB height including Arduino connector

Length 100 EVB length

Width 70 EVB width

Table 2 EVB dimensions

3 POWER SUPPLY The EVB power can be provided by USB hosts or an external 5V supply which is then converted by LDOs to create the 3.3V and 1.8V needed for the onboard circuits. There is no switch needed for selecting a particular supply. Instead, diodes are installed to provide reverse current protection for each individual supply. Jumpers CN11 may be used to measure the current consumption of the module as described in Section 9. A block diagram of the power supply connections is shown below.

Figure 5 Power supply block diagram

3.1 USB power supply

In the default configuration, the EVB is connected to a PC through at least one of the two mini-USB ports CN13 and CN14. These connections provide the USB-UART serial interfaces and serve as the power sources for the EVB. The mini-USB connector locations are as shown below in Figure 6.

Figure 6 USB connectors location

Page 10: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 10 of 44 www.murata.com

3.2 External 5V supply

The EVB can also be powered by applying 5V to the Ext_Vin pin of the Arduino interface. This is pin 8 on the CN3 header which is located on the bottom side of the EVB as shown in Figure 7.

Figure 7 Ext_Vin pin location on bottom side of EVB

4 SERIAL INTERFACES The EVB exports 3 module UART ports through either the USB-UART mini-USB connectors or the Arduino header. A block diagram for this is shown in Figure 8.

Figure 8 Exported UART interfaces

In the default configuration, USB ports CN13 (UART A & C) and CN14 (UART B) are connected to a PC for application testing and development; the Arduino interface is not used. The host control for the modem is accomplished through the UART B (CN14) interface. There are two possible options:

• Use a PC application (e.g., PuTTY): connect a mini-USB cable to CN14 and disconnect the Arduino interface. See Section 0 for more instructions.

• Use the Arduino interface (e.g., Nucleo 64 board): connect MCU to the Arduino interface and disconnect the mini-USB cable from CN14. See Section 6.1 for the detailed Arduino interface pin assignments.

UART A & C (CN13) are used for CLI and debugging. See Sections 7.4 for more details.

Ext_Vin

3V3_IO

Page 11: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 11 of 44 www.murata.com

5 INDICATION AND SERVICES

5.1 Optical Indicators

The EVB has 3 LEDs which serve as status indicators. Their locations on the EVB are shown below.

Figure 9 LED locations on EVB

5.1.1 LED1: PMU_EXT_ALARM status

LED1 shows the power save mode status of the module. It is on whenever the module is not in one of the low power sleep states.

5.1.2 LED2: PWM3 status

LED2 is the status of the PWM3 pin.

5.1.3 LED3: SMA / ANT select status

LED3 indicates the antenna selection status: ON if the SMA connector is connected to the LTE RF path; OFF if the RF is routed to the onboard antenna. By default, the SMA connector is selected.

5.2 Services

The EVB has four push buttons which can be used to reset the module or place it in recovery mode.

Figure 10 Button locations on EVB

LED3

LED2

LED1

SW2 SW3

SW1

SW4

Page 12: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 12 of 44 www.murata.com

5.2.1 Reset operation

The module can be reset by pressing buttons SW1.

5.2.2 Recovery operation

The module can be placed in recovery mode by the following sequence: 1. Press and hold SW4 2. Press and release SW1 3. Release SW4

5.2.3 Wakeup operation

While the module is in sleep mode, press and hold SW2 to wake it up.

Pressing SW2 is only necessary if a PC terminal is not connected to the Murata module through the USB via CN14. Otherwise, the CTS signal from that USB-UART connection will keep the module awake.

5.2.4 Reserved operation

The function of SW3 is currently reserved.

6 MODULE IO INTERFACE The EVB exports the Arduino and expansion headers for access to the module IOs.

6.1 Arduino interface

The module exports the modem UART control interface to the Arduino headers. The external MCU signals are level-shifted to the 1.8V levels required by the module. To use the Arduino interface, disconnect the cable from mini-USB port CN14 and establish the following connections to the Arduino headers:

• MCU reference voltage to IOREF

• 5V supply to VIN

• MCU GND to EVB GND

• MCU UART to corresponding modem UART pins The pin assignments for the Arduino interface are shown below.

• I/Os levels are defined by IOREF to be either 1.8V/3V/5V • Signal with (DNS) is not connected by default, but can be connected with a 0Ω resister • Signal with (0Ω) is connected by default, but can be disconnected by removing the 0Ω resister

Signal Pin# EVB Direction Description

1

IOREF 2 IO_REF I MCU IO voltage reference

3 RESET_IO (0Ω) Signal to reset modem if pins 5 and 16 of CN11 are connected.

4

5

GND 6 GND -- Ground

GND 7 GND -- Ground

Page 13: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 13 of 44 www.murata.com

VIN 8 Ext_Vin I 5V input for EVB. See more details in Section 3.2.

A0 1 UART0_RTS_IO (0Ω) O Level shifted UART0_RTS

A1 2 UART0_CTS_IO (0Ω) I Level shifted UART0_CTS

A2 3

A3 4

A4 5 RESET_IO (DNS) I Optional signal to reset modem

A5 6 LDO_EN (DNS) I Optional signal to enable VBAT and VBAT_FEM LDOs

Table 3 Arduino shield headers: CN3 (power) + CN4 (analog)

Signal Pin# EVB Direction Description

D15 10

D14 9

AREF 8

GND 7 GND -- Ground

D13 6

D12 5

D11 4

D10 3

D9 2 PWM0_RST_IND_IO(DNS) O Optional level shifted signal

D8 1

D7 8 SC_SWP_IO (DNS) O Optional level shifted signal

D6 7

D5 6

D4 5 PMU_WAKEUP_IO (DNS) I Optional level shifted signal

D3 4

D2 3

D1 2 UART0_RX_IO (0Ω) I Level shifted UART0_RX

D0 1 UART0_TX_IO (0Ω) O Level shifted UART0_TX

Table 4 Arduino shield headers: CN10 (D8-D15) + CN9 (D0-D7)

6.2 Expansion headers

The EVB provides a set of expansion headers to access the module IO pins. The assignments for these headers are shown below.

• Signal with (DNS) is not connected by default, but can be connected with a 0Ω resister • Signal with (0Ω) is connected by default, but can be disconnected by removing the 0Ω resister

Signal Pin# EVB Level Direction Description

XP1 16

XP2 15 IO_REF IOREF I MCU IO voltage reference

XP3 14

XP4 13

Page 14: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 14 of 44 www.murata.com

XP5 12 4V3_SUPP 4.3V O 5V output from USB ports after diode drop

XP6 11

XP7 10

XP8 9

XA0 12 UART0_RTS_IO IOREF I/O Level shifted UART0_RTS

XA1 11 UART0_CTS_IO IOREF I/O Level shifted UART0_CTS

XA2 10

XA3 9

XA4 8

XA5 7

Table 5 Expansion headers pinout: CN3 + CN4

Signal Pin# EVB Level Direction Description

XD15 11

XD14 12

XDA 13 VDDIO 1.8V O 1.8V reference from modem

XDG 14

XD13 15

XD12 16

XD11 17

XD10 18

XD9 19 PWM0_RST_IND_IO IOREF O Optional level shifted signal

XD8 20 PWU_EXT_ALARM_IO IOREF O Level shifted signal indicating Device Status

XD7 9 SC_SWP_IO IOREF O Optional level shifted signal

XD6 10

XD5 11

XD4 12 PMU_WAKEUP_IO IOREF I Optional level shifted signal to wakeup module

XD3 13

XD2 14 PMU_POWER_BUTTON_IO IOREF I Level shifted Modem power button

XD1 15

XD0 16

Table 6 Expansion headers pinout: CN10 + CN9

Page 15: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 15 of 44 www.murata.com

7 STARTUP PROCEDURE Unpack the EVK package and use the following steps to setup the reference PC environment and configure the EVK. The ensuing discussions are based on a PC running Windows 10 Pro. Do not connect to the Arduino interface.

7.1 Install PuTTY

Download and install PuTTY for Windows from https://www.putty.org. This is the recommended serial port console for PC serial communication with the module.

7.2 Connection to PC

Connect two USB cables from a PC to the two mini-USB ports labeled CN13 and CN14. The driver should be automatically installed for the two UART ports (A & C) associated with CN13.

Figure 11 EVK setup

The driver for UART B associated with CN14 needs to be installed manually.

• Open the following web page: https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-drivers.

• Download the latest version of universal driver for Windows 10.

• Unzip the downloaded zip file, and run CP210xVCPInstaller_x64.exe to install the driver. After the above steps, there should be three COM ports shown in Device Manager -- one for Debug (e.g. COM8, 921600 baud), one for CLI (e.g. COM9, 115200 baud), and one for AT (COM13, 115200 baud). See below an example screenshot of the Device Manager.

Page 16: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 16 of 44 www.murata.com

Figure 12 COM ports assignment shown in Device Manger

7.3 AT/PPP port

By default, UART B is the dedicated AT/PPP port. Start a PuTTY session and connect to the AT port. The baud and flow control of PuTTY session, respectively, need to be set to 115200 8N1 and “None”.

If the driver is installed properly but there is no response from the module, use the CLI port to ensure that the modem is not in the u-boot mode (See Section 7.4 for details).

Figure 13 PuTTY configuration for AT port

Page 17: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 17 of 44 www.murata.com

7.3.1 AT commands

The module supports a subset of standard 3GPP AT commands and a set of proprietary commands.

• Standard AT commands start with “AT+”,

• Proprietary AT commands start with “AT%”.

All commands are case insensitive. Here is a list of some useful AT commands.

- at%ver to list versions - at+cgmi to read name of manufacturer - at+cgmm to read model number - at+cgsn to read IMEI number - at+cgmr to read software version - at%ccid to check SIM card status

7.3.2 From AT Channel to PPP Channel

The user can switch between an AT channel to a PPP channel as follows. See Section 8 for the details to create the PPP interface with a PC.

1. Connect a mini-USB cable to the CN14 (UART B) port. 2. Open a terminal shell to the AT channel COM port (the default functionality of UART B is AT

channel). 3. In order to switch to the PPP channel functionality, the user needs to run the ‘ATD*99’ AT

command. 4. After step #3, the AT channel will switch to a PPP channel, on which the user can establish a

PPP connection. 5. In order to switch back to AT channel functionality, the user needs to follow the steps below (in

the PPP terminal): a. Enter the ‘+++’ command without pressing the ‘Enter’ key. b. Wait for one second (at least). c. Press the ‘Enter’ key.

6. After step #5, the terminal will suspend the PPP and switch back to an AT channel terminal. 7. Now the port accepts regular AT commands; ATO and AT%H0, respectively, can be used to

resume and terminate the PPP session.

7.4 CLI port

The CLI port is intended for testing purposes and allows the user to enter commands to interact with the module. Open PuTTY to the CLI port. The following screenshot shows how to save the configuration as “COM9” for later use.

Page 18: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 18 of 44 www.murata.com

Figure 14 PuTTY configuration for CLI port

After connecting to the CLI port, check the prompt. If the prompt is “#”, that means the firmware is in u-boot mode. Enter “boot” command to boot it up; after boot up, the prompt should change to “>”. This is illustrated below.

Figure 15 Prompt for CLI Port

7.4.1 CLI commands

All supported CLI commands can be seen with the “help” command. The “help” command lists categories of CLI commands. Use “help <category>” to see commands under a particular category.

Page 19: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 19 of 44 www.murata.com

Figure 16 CLI Commands

Here is a list of example CLI commands.

- ver to show the current version of the firmware installed - ifconfig to show the interfaces - ping 127.0.0.1 to ping an IP address

7.4.2 Sending AT commands from CLI channel

The CLI channel supports sending AT commands to the modem, as follows: at <AT command> For example:

- at at+cfun? - at at%ccid

7.4.3 From CLI Channel to AT Channel

The user can switch a CLI channel to an AT channel as follows:

1. Connect a UART serial cable to the device’s CN13 (UART A & C) mini-USB connector. 2. Open a terminal shell to the CLI COM port (the default functionality of UART A is CLI). 3. To switch to the AT channel functionality, run the ‘serialSwitch’ CLI command. 4. After step #3, the terminal will switch to an AT channel terminal and the user can run normal

AT commands in it – there is no need for the extra “AT” as in the case with the CLI port. 5. To switch back to CLI functionality, run the ‘at%cli’ AT command. 6. After step #5, the terminal will switch back to a CLI terminal.

8 PPP LTE Connection – Windows Connect both CLI and AT port from the EVB to PC. Use PuTTY to connect to CLI port to make sure the modem is in application mode (“>” prompt is shown).

Page 20: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 20 of 44 www.murata.com

A valid SIM card inserted into the SIM slot is needed for LTE connection

Use the following steps to make the PPP connection for Windows to connect to the internet.

8.1 Creating a modem

1. Go to ‘Control Panel’ and select ‘Phone and Modem,’ select the ‘Modems’ tab, then click ‘Add.”

Figure 17 Modems Tab

The “Add Hardware Wizard” displays.

Figure 18 ‘Add New Hardware Wizard’

2. Click ‘Next’ to go to the next screen.

Page 21: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 21 of 44 www.murata.com

Figure 19 Next Screen

3. Click ‘Next’ to select ‘Standard 28800 bps Modem.’

Ensure that ‘Standard 28800 bps Modem’ is selected.

Figure 20 Modem Selection

4. Ensure there is no PuTTY session connected to the AT port. Click ‘Next’ to select the AT port.

Page 22: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 22 of 44 www.murata.com

Figure 21 Click Selected Ports

5. Click “Next”, then the “Finished” button. A screen like the following would be shown.

Figure 22 Modems Installed

6. Click “Properties”. The Device Status screen is then shown.

Page 23: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 23 of 44 www.murata.com

7. Click ‘Change settings’. In the Modem tab, change baud rate to 115200.

Figure 23 Set the Baud Rate

8. Click ‘OK’ twice on the modem window to complete the setup.

8.2 Creating PPP connection entry

1. Go to ‘Control Panel’ and type in ‘dial-up’ in the search bar.

Page 24: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 24 of 44 www.murata.com

Figure 24 Accessing dial-up connection

2. Select ‘Set up a dial-up connection’ and then click ‘Next’.

Figure 25 Creating Dial-up Connection

3. Enter “*99” for ‘Dial-up phone number,’ enter a name for the ‘Connection name’ e.g., “PPP”, then click ‘Connect’. After Step 3, it may take some time for the connection action to fail. In that case, stop the dialing process by clicking ‘Skip’ to stop the connection. A dialog similar to the following should be shown:

4. Click ‘Close’ to go to the next step.

Page 25: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 25 of 44 www.murata.com

Figure 26 Connection is Ready

5. If the connection fails with an error before the actions in Step 4 complete, a dialog similar to the following displays. Click ‘Set up the connection anyway’ and close.

Figure 27 Set Connection Anyway

6. Open ‘Network and Sharing Center’ under control panel and select ‘Change adapter settings’.

Page 26: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 26 of 44 www.murata.com

Figure 28 Access for Change Adapter Settings

Figure 29 Change Adapter Settings

7. Right click on the ‘PPP’ connection and select ‘Properties’.

Page 27: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 27 of 44 www.murata.com

Figure 30 PPP Properties

8. Click on ‘Configure’ and change baud rate to 115200, then close the windows.

8.3 Establishing the LTE connection

Insert the SIM card, reset the EVB, wait until LTE connection is established. The CLI console can be used to view the LTE connection process, as shown below.

Page 28: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 28 of 44 www.murata.com

Figure 31 CLI Console

8.4 Making the PPP connection

1. Open PuTTY on AT port, enter ‘at&k3’ to enable HW flow control, and then close PuTTY.

Figure 32Enabling hardware control

Page 29: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 29 of 44 www.murata.com

2. Open PuTTY on CLI port to monitor progress.

3. Double click the ‘PPP’ connection from the Network Connections panel.

Figure 33 PPP Connection – Network Connections Panel

4. In Windows 10, a popup screen similar to that shown below may appear at the lower right

corner.

Figure 34 Windows 10 Pop-Up Screen

5. Click on ‘PPP’.

Page 30: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 30 of 44 www.murata.com

Figure 35: Click “PPP”

6. Select the ‘PPP’ connection under ‘Dial-up’ then click on ‘Connect’

Figure 36 Connect “PPP”

Page 31: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 31 of 44 www.murata.com

7. Click on the ‘Properties’ button and then select the ‘Options’ tab. Make sure that the box is not checked for ‘Prompt for name and password…’ and then press OK.

Figure 37 Options

8. Click ‘Dial’. The CLI console should show PPP connection.

Figure 38 PPP Connection

Page 32: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 32 of 44 www.murata.com

9. Open a command prompt in Windows, and enter ‘ipconfig’. The PPP connection should

appear. If the routing is setup correctly, any internet traffic should now go through the PPP connection.

Figure 39 PPP Connection

Disable Ethernet or WiFi on the PC to ensure the internet connection is only through the LTE module.

Since the baud rate for the PPP port is 115200kbps, the data throughput is low. There are many PC programs sending and receiving packets to the network which now all use this PPP connection. Make sure any traffic heavy programs such as the web browser are closed when testing the internet connection via LTE.

9 Current measurement Configure the board as follows to use a power module that has its own meter, such as a Keysight N6705C DC Power Analyzer + N6781A power module as shown in Figure 40.

• Remove jumpers on pin 18, 19 on CN11

• Connect DC supply to both 18 and 19 which provides VBAT and VBAT_FEM, respectively

• Jump ANT_SEL (6 on CN11) to GND (15 on CN11) to select SMA antenna

• Connect the EVB to the PC

• The LTE connection can be either to a tester such as CMW500 or to the live network

The supply must be in the range of 3.2V to 4.2V and capable of delivering 1A of current.

Page 33: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 33 of 44 www.murata.com

Figure 40 Power supply setup with Keysight power module

Instead of using an external power supply, it is also possible to measure the VBAT and VBAT_FEM power consumption by using an amp meter to measure the current through the terminals of 18 and 19, respectively.

10 Firmware Upgrade Use the following steps to change the module firmware.

1. Download the PCTool software and new firmware image. Contact Murata at [email protected] for access.

2. Install both packages on a Windows PC.

3. After both packages are installed, start the Image Burn Tool utility (All Programs->Altair Semiconductor->PcTools). The new version of firmware should show up in the “Version” field.

4. Ensure that “System Header”, “U-Boot + Env”, “Flexible Partition Map”, “Application FW”, “Modem FW 1”, and “Modem FW 2” fields are all checked.

DO NOT check Configuration FS.

5. Select the CLI COM port for the UART port in Burning Options. The Baud Rate should be “3000000” and Flow Control should be “RTS_CTS”. See the screen shot below for details. Some PCs might have a hard time running at 3000000 if so try changing the Baud Rate to 921600.

Page 34: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 34 of 44 www.murata.com

Figure 41 Image Burn Tool configuration

6. Click on the “Burn” button to start the upgrade process. You will be prompted to reset the unit and then click the OK button. The firmware will take several minutes to upgrade, but there is no other input required from the user.

11 EVK Schematics

MUST not check! CLI portwith HW FC

Page 35: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 33 of 44 www.murata.com

Page 36: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 36 of 44 www.murata.com

Page 37: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 37 of 44 www.murata.com

Page 38: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 38 of 44 www.murata.com

Page 39: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 39 of 44 www.murata.com

Page 40: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 40 of 44 www.murata.com

Page 41: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 41 of 44 www.murata.com

Page 42: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 42 of 44 www.murata.com

Page 43: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/25/2018 Page 43 of 44 www.murata.com

12 SAFETY RECOMMENDATIONS

12.1 Disposal of this product in the European Union

For private households: Information on Disposal for Users of WEEE This symbol on the product(s) and / or accompanying documents means that used electrical and electronic equipment (WEEE) should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product(s) to designated collection points where it will be accepted free of charge. Alternatively, in some countries, you may be able to return your products to your local retailer upon purchase of an equivalent new product. Disposing of this product

correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation. For professional users in the European Union: If you wish to discard electrical and electronic equipment (EEE), please contact your dealer or supplier for further information.

12.2 Disposal of this product in other countries outside the European Union

This symbol is only valid in the European Union (EU). If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal.

Page 44: LTE CAT-M1 / NB-IoT EVK · Title: Type 1SC, Type 1SC-DM and Type 1SE | EVK User Guide | LTE-M PSM and eDRX Module | Murata Manufacturing Co., Ltd. Subject

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 2018

Type 1SC EVK User Guide, v1.3, 5/4/2020 Page 44 of 44 www.murata.com

13 ACRONYMS ADC Analog-to-digital converter

AT Abbreviation for Attention.

BPS Bits per second

CLI Command line interface

COM Abbreviation for communication

CTS Clear-To-Send

DNS Do Not Stuff

EVB Evaluation Board

EVK Evaluation Kit

FTP File Transfer Protocol

FW Abbreviation for firmware

GND Abbreviation for ground

GNSS Global Navigation Satellite System

HW Abbreviation for hardware

ICCID Integrated Circuit Card Identifier

IoT Internet of Things

I/O or IO Input/Ouput

I/OREF Input/Ouput voltage reference

LDO Low-drop out regulator

LED Light-emitting Diode

LTE Long-Term Evolution

MCU Abbreviation for microcontroller

PC Personal Computer

PMU Phase measuring units

PPP Point-to-Point Protocol

PWM Pulse Width Modulation

RAM Random Access Memory

ROM Read Only Memory

RF Radio Frequency

SIM Subscriber Identity Module

SW Abbreviation for software

USB Universal Serial Bus

UART Universal Asynchronous Receiver Transmitter

VBAT Voltage of the Battery

u.FL A type of RF connector

VIN Input Voltage