32
Low Level MIP Technology from Geoprobe Systems ® Geoprobe ® -DI Dan Pipp June 2017 1

Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Low Level MIP Technologyfrom Geoprobe Systems®

Geoprobe®-DIDan Pipp

June 2017

1

Page 2: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

The Low Level (LL) MIP method significantly improves MIP detector sensitivity and signal to noise ratios.

Users will have greater confidence with their results when LL MIP is used where standard MIP detector signals have reached their practical limits.

LL MIP expands the utility of MIP by mapping certain VOC plumes an order of magnitude lower than the standard MIP method.

Standard MIP is still required in areas of ample and robust signal.

2

LL MIP Method

Page 3: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

3

➢ Enhances detector sensitivity ~10x.

➢ Adaptable to existing FI based MIP systems.

➢ Operate with any MIP probe or trunkline.

➢ Method is fully automated in software.

➢ Simple to switch between methods.

LL MIP Technology

Page 4: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

TL carrier flow is stopped.

Under a concentration gradient VOCs move across the membrane via diffusion.

In the LL method, VOCs will accumulate behind the membrane until the TL carrier gas flow is resumed. Then the contaminant mass (peak) is transported to the detectors.

4

LL MIP OperationCarrier Gas is Stopped

Probe Body

Semi-permeable Membrane

VOCs in Soil

VOCs Collect Behind the Membrane

Page 5: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

5

Comparison of 500ppb TCE standard response tests performed by standard MIP and LL MIP methods.

500ppb TCE Response Test

Standard MIP LL MIP

LL MIP Method

Page 6: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Operate LL technology with an FI based MIP system with any standard gas phase detectors.

6

LL MIP Equipment

Page 7: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

7

Operate LL MIP technology with any MIP trunkline or MIP tooling package you plan to utilize

➢MIP➢MiHpt➢MIP-CPT➢MIP-HTL

LL MIP Equipment

Page 8: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

8

Only additional piece of equipment needed to operate the LL MIP method.

Add this controller to your existing FI based MIP system.

LL MIP Controller - MP9000

LL MIP Equipment

Page 9: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

9

MP9000LL MIP

MP6505

FI6000

GC1000PID, FID, XSD

TL Supply and Return Gas Lines

Detector Carrier Gas Supply

Carrier Gas out to Detectors

Regulated Output

MP9000 LL MIP Controller is inserted intostandard FI Based MIP System.

LL MIP System Setup

Page 10: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

10

TCE in PPB 0 25 50 100

LL MIP Response Testing

Page 11: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Former Dry CleanersSite Contaminants Include:PCE, TCE

Field Site ExamplesSlangerup, Denmark

Page 12: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

12

MIP XSD - TCE PPB

0 10 50 100 250 500 1,000

Detection limit study by a Danish LL MIP provider has shown the TCE detectable at 10ppb with the 50ppb response achievable throughout a project based upon surface response tests.

LL MIP Response Testing

Page 13: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

13

EC HPT PSI PID XSD FIDLL MIP Logs

Page 14: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

14

EC vs. XSD response

These 3 logs move away from the source - left to right.

The middle log is approximately 15’ higher in elevation than the other 2 logs.

LL MIP Log Cross section

Page 15: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

x

Former Gas StationPetroleum release

Barn

ey S

t.

Field Site ExamplesSalina, KS

Page 16: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

16

Logs were run on the edge of a hydrocarbon plume

Overlay of:LL MIP log - redStandard MIP log - black

Detector response in fine grain lithology

LL MIP Logs

Page 17: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

17

Close up comparison of the PID & FID responses from the log on previous slide.

LL MIP Logs

Page 18: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

18

Logs were run on the edge of a hydrocarbon plume.

Overlay of:LL MIP log - redStandard MIP log - black

Fine Grain Lithology

LL MIP Logs

Page 19: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

19

Standard MIP PID vs. LL MIP PID Response

Std. MIP LL MIP Std. MIP LL MIPautoscaled synched graph scales

LL MIP Logs

Page 20: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Wall St

x

Former Military AirfieldSite Contaminants Include Primarily: TCE, Carbon Tetrachloride

Scan

lon

Ave

x

Field Site ExamplesSalina, KS

Page 21: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

21

Standard MIP-XSD Log WS19 with Soil Sample Results

Soil results 10’-20’ are all <50µg/kg

Higher soil results below 20’ correspond with higher detector signal

Soil samples contain TCE and some carbon tetrachloride.

Page 22: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Standard MIP – LL MIP Comparison

22

MIP Logs: WS19 WS LL MIP 02Std MIP LLMIP

0-500mg/kg CVOC

Logs run within 3’

The clean XSD baseline allows the LL MIP log to expose the <50µg/kg concentrations above 20’

The readings below 20’ jump out making field decisions easier

Page 23: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

LL MIP Log in mixed hydrocarbon –CVOC plume

Graphs L-R: EC, PID, FID, XSD

Hydrocarbons to 20’CVOCs 20-30’

Fine grained lithology

23

LL MIP Logs

Page 24: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

24

Logs on the edge of a XVOC plume

Overlay of:LL MIP log - redStandard MIP log - black

Fine grained lithology

LL MIP Logs

Page 25: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

25

Close up comparison of the XSD responses from the log on previous slide compared to a co-located standard MIP log.

Standard MIP – leftLL MIP – right

LL MIP Logs

Page 26: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

x

Grain Elevator SpillSite Contaminants Include Primarily: 1,2-DCA, Chloroform and Carbon Tetrachloride

N. 5

th S

t.

x

Grain Elevators

Field Site ExamplesSalina, KS

Page 27: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

27

Logs on the edge of a XVOC Plume

Overlay of:LL MIP log - redStandard MIP log - black

Coarse grain lithology

LL MIP Logs

Page 28: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

28

Close up comparison of the XSD responses from the log on previous slide.

Standard MIP – leftLL MIP – right

LL MIP Logs

Page 29: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

29

Replicate LL Logs with Analytical data

Coarse grained lithology

DCA = 1,2-DichloroethaneCT = Carbon TetrachlorideCFM = Chloroform

LL MIP Logs

Page 30: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

30

Replicate LL Logs with Analytical data

Coarse grained lithology

DCA = 1,2-DichloroethaneCT = Carbon TetrachlorideCFM = Chloroform

LL MIP Logs

Page 31: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

➢ Improves detector sensitivity ~10x➢ Define plumes further with greater confidence➢ Capable of tracking plumes to <50ppb range➢ Add controller to FI based MIP system➢ Increase the utilization of your MIP system➢ Does not replace standard MIP logging

LL MIP Chloroform Response

100ppb 500ppb

31

LL MIP Method Summary

Page 32: Low Level MIP Technology - Geoprobe Systems® · LL MIP log - red Standard MIP log - black Detector response in fine grain lithology LL MIP Logs. 17 Close up comparison of the PID

Geoprobe Systems®

1835 Wall StreetSalina, KS 674011-800-436-7762geoprobe.com

Copyright© 2017 by Kejr Inc.

All Rights Reserved

32