LC-4221-K050LC-4221-K300
Hermetically Sealed, Beam Type Stainless Steel Load CellIdeal for measurements in harsh environments
Loadcell
1800 241 4341800 241 434 For more information please call:
Loadcell
300 300kgf (2.94kN)
3
http://www.aandd.jp
…Clearly a Better Value
ContentsTerminology of Load Cells
Single point LCB03/04 Series LCB05 Series LC-4001 LC-4101 Series LC-4102 Series LC-4103 Series LC-4204 Series
Beam Type LCM13 Series LC-4221 Series LC-5206 Series LC-5223 Series
Tension Type LC-1205 Series LC-1216 Series
Compression Type LCC07 Series LCC11/N Series LCC12 Series
Equipment
Accessories
3
456789
1011
1213141516
171819
20212223
24
26
2
Hysteresis
NonlinearityCombined error
Load
Output
Load Cell TerminologyEach country has its own standard for the performance and quality of load cells. In Japan, there is no standard stipulated uniquely for load cells, although JIS (Load Cell - Test Method JIS B7602) and JMIF (Japan Measuring Instruments Federation) prescribe methods for performance tests.Meanwhile, the OIML (International Organization of Legal Metrology) sets the international recommendation titled “Metrological Regulation for Load Cells,” with which each member country tries to make their local regulation consistent. The terms described below are commonly used by the OIML and its member countries.
Rated Capacity (RC)The maximum load that a load cell can measure while meeting its specifications.
Rated Output (RO)The difference when there is no load and when there is a load of rated capacity. It is generally expressed in output per excitation voltage (mV/V). Alternatively called “Span.”
Safe load limitThe maximum load that can be applied beyond the rated capacity without causing any permanent damage. Expressed as a percentage of rated capacity.
Compensated temperature rangeThe temperature range within which the rated output and the zero balance are compensated to meet the specifications.
Temperature effect on zero balanceDrifting of the zero balance caused by changes in the ambient temperature. Expressed as a percentage of rated output.
Temperature effect on rated outputDrifting of the rated output caused by changes in the ambient temperature.
NonlinearityThe maximum deviation in output from the linear calibration curve linking the zero balance and the rated output, which is measured only when the load increases. Expressed as a percentage of rated output.
Hysteresis errorThe maximum difference in output between when the load increases and when the load decreases.
Combined errorThe maximum deviation of output from the linear calibration curve linking the zero balance and the rated output, including when the load increases and decreases.
Recommended/maximum excitation voltageThe voltage applied to the input terminals of load cell.
Zero balanceThe electrical output when the rated excitation voltage is applied without any load on the cell. Generally expressed as a percentage of rated output.
Input terminal resistanceMeasured while the input terminals are open, with no load on the cell.
Output terminal resistanceMeasured while the input terminals are open, with no load on the cell.
Insulation resistanceThe direct current resistance between the load cell unit and its circuit.
3
200(
MAX
)
200(MAX) 200(MAX)
200(
MAX
)
Corner point
Platform
Platform
Platform specer Corner stopper
Corner stopperCorner lineof platform
Base
Unit = mm
Single PointSingle-point load cells are ideal to be used alone and for relatively small loading.Already adjusted to correct four-corner errors.
Example ApplicationslElectronic balances
lDesktop scales
lSmall/medium-sized platform scales
lConveyer scales, etc.
Example of InstallationUsing LCB04
4
Single Point
LCB04 Series
LCB03 Series
LCB03M/L Series
LCB04M Series
LCB04L Series
1304-M612 106 12
15 30(40)
25 80 25
22
(40) : L Series
1501026 18 18 6
18 4018
4-M6 16mm deep
M6 34mm deep
2-M6 16mm deep
30
30
34
1509820 20 66 4-M8 16mm deep
20 40
32
324-M8 16mm deep
20
34
Unit = mm
CABLE COLOR CODERED EXC+WHITE EXC–GREEN SIG+BLUE SIG–YELLOW SHIELD
Net Weight : 0.23kg(L Series : 0.3kg)
Net Weight : 0.5kg
Net Weight : 0.5kg
LCB03/04 SeriesSingle-point Aluminum Load Cell
LCB03K003M
LCB03K006M
LCB03K010M
LCB03K015M
LCB03K020M
LCB03K025L
LCB03K030L
LCB03K035L
LCB03K060L
LCB04K060M
LCB04K100M
LCB04K150L
LCB04K250L
3kgf (30N)
6kgf (60N)
10kgf (100N)
15kgf (150N)
20kgf (200N)
25kgf (250N)
30kgf (300N)
35kgf (350N)
60kgf (600N)
60kgf (600N)
100kgf (1kN)
150kgf (1.5kN)
250kgf (2.5kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
2mV/V±10%
150% of R.C.
0.02% of R.O.
DC12V
DC15V
±5% of R.O.
420±30Ω350±5Ω2000MΩ/DC50V(B/E)
–10ºC to 40ºC
0.023% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø3.5/0.4m (LCB03)
ø3.5/1.5m (LCB04)
3005300mm (LCB03)
4005400mm (LCB04)
IP54
Model No. Capacity
LCB03M Series
LCB03L Series
LCB04M Series
LCB04L Series
M6
M6
M6
M8
Bolt diameter
12Nm
12Nm
12Nm
30Nm
Clamping torque
Applicable clamping torque
5
Single Point
15010
18 6
40
2-M6 Depth 15mm M6 Pierced
18
378.5
4-M4 Bolt with Hexagonal hole
8632
19
6.5
32
30
18
18102186
15010
40
620
20
378.5
32
30
6.5
19
8632
6 20 98 20
20
LCB05K030/060
LCB05K150
Unit = mm CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
4-M8 Depth 15mm
4-M4 Bolt with Hexagonal hole
4-M6 Depth 12mm
4-M8 Depth 12mm
Net Weight : 1.2kg
Net Weight : 1.2kg
LCB05 SeriesHermetically Sealed Single-point Stainless Steel Load CellIdeal for measurements in harsh environments
LCB05K030
LCB05K060
LCB05K150
30kgf (300N)
65kgf (600N)
150kgf (1.5kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
2mV/V+15% –0%
150% of R.C.
0.03% of R.O.
DC12V
DC15V
±5% of R.O.
Approximately 390Ω350±5Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø5.6/3m
4005400mm
IP67
Model No. Capacity
LCB05K030
LCB05K060
LCB05K150
M6
M6
M6
Bolt diameter
12Nm
12Nm
28Nm
Clamping torque
Applicable clamping torque
6
Single Point
Net Weight : 0.26kgUnit = mm
F.P.C. connection code1. Excitation –2. Signal –3. Excitation + 4. Signal + 5. N.C.
Depth 8
Appr
ox. 6
6
LC-4001Single-point Aluminum Load Cell with Ultra-high SensitivityHigh resolution, as high as 10mgBuilt-in metal overload stopper
LC-4001-G120 120gf (1.177N)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
0.4mV/V or greater
300% of R.C.
0.015% of R.O.
DC12V
DC15V
±25% of R.O.
Approximately 400Ω350±5Ω500MΩ/DC50V
–5ºC to 35ºC
0.14% of R.O./10ºC
0.02% of Load/10ºC Typ.
F.P.C.75mm
1205120mm
IP22
Model No. Capacity
LC-4001-G120 M4
Bolt diameter
1Nm or below 10mm or below
Clamping torque Screw-in depth
Applicable clamping torque
* F.P.C. compliant connector HBLB5S-5J (Japan FCI)
7
Single Point
Net Weight : 0.12kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
6-M4 Depth 10
Approx.1.5m ø4
LC-4101 SeriesSingle-point Aluminum Load Cell Ideal for Small Capacity Weighing
LC-4101-G600
LC-4101-K1.5
LC-4101-K003
LC-4101-K006
LC-4101-K015
600gf (5.88N)
1.5kgf (14.7N)
3kgf (29.42N)
6kgf (58.8N)
15kgf (147N)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
1mV/V+15% –0%
300% of R.C.
0.015% of R.O.
DC12V
DC15V
20±5% of R.O.
Approximately 400Ω350±5Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø4/1.5m
3005300mm
IP22
Model No. Capacity
LC-4101 Series M4
Bolt diameter
3Nm 6 to 8mm
Clamping torque Screw-in depth
Applicable clamping torque
8
Single Point
Net Weight : 0.6kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
4-M6 Depth 15Rear
Cable
2-M6 Depth 15Protective cover M6 Pierced
Loading area
Width of shelf
Load
LC-4102 Series
LC-4102-K010
LC-4102-K010
LC-4102-K010
LC-4102-K010
LC-4102-K010
10kgf (98.1N)
15kgf (147N)
30kgf (294N)
60kgf (588N)
150kgf (1.47kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
1mV/V+15% –0%
300% of R.C.
0.015% of R.O.
DC12V
DC15V
20±5% of R.O.
Approximately 400Ω350±5Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø4/1.5m
4005400mm
IP54
Model No. Capacity
Single-point Aluminum Load Cell Ideal for Small / Medium Capacity Weighing
LC-4102 Series M6
Bolt diameter
15Nm 10 to 13mm
Clamping torque Screw-in depth
Applicable clamping torque
9
Single Point
Net Weight : 1.2kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
Loading area
Width of shelf
Load
Depth 22M8 Pierced
Protective cover
LC-4103 SeriesSingle-point Aluminum Load Cell Ideal for Medium Capacity Weighing
LC-4103-K060
LC-4103-K100
LC-4103-K150
60kgf (588N)
100kgf (981N)
150kgf (1.47kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
1mV/V+15% –0%
300% of R.C.
0.015% of R.O.
DC12V
DC15V
20±5% of R.O.
Approximately 400Ω350±5Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø6/2m
4005600mm
IP54
Model No. Capacity
LC-4103 Series M8
Bolt diameter
30Nm 15 to 20mm
Clamping torque Screw-in depth
Applicable clamping torque
10
Single Point
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD Net Weight : 2kg
Unit = mm
Loading area
Width of shelf
Load
4-ø13 Pierced 4-M12 Pierced
Protective cover
LC-4204 Series
LC-4204-K300
LC-4204-K600
300kgf (2.94kN)
600kgf (5.88kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Maximum platform size
Dustproof/waterproof
1.5mV/V±0.2%
200% of R.C.
0.015% of R.O.
DC12V
DC15V
20±5% of R.O.
Approximately 400Ω350±5Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø6/5m
6005700mm
IP54
Model No. Capacity
Single-point / Multi-point Aluminum Load Cell
LC-4204 Series M12
Bolt diameter
80Nm
Clamping torque
Applicable clamping torque
11
Leveling foot
Platform
Load cell
Platform
Frame
Socket
BallSocket
Load cell
Beam TypeBeam type (multi-point) load cells are suitable for large capacity weighing.Ideal for low-profile scales.
Example ApplicationslPlatform scales
lHopper scales
lTank scales
lConveyer scales, etc.
Example of InstallationUsing LCM13
12
Beam Type
LCM13K200
LCBM13T002
Net Weight =kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
G I
AB C D E
H
FJ
KLM
AB C D E
F
IHG
JK
LM
LCM13K500 / LCM13T001 / LCM13T002LCM13T003
LCM13T005
Model No.LCM13K100LCM13K200LCM13K300LCM13K500LCM13T001LCM13T002LCM13T003LCM13T005
A
130
130
171
171
B
16
16
19
19
C
25
25
38
38
D
76
76
95
95
E
13
13
19
19
F
32
32
38
43
G
2-ø14
2-ø14
2-ø21
2-ø21
H
M12
M12
M20
M20
I
ø21
ø21
ø30.2
ø30.2
J
32
32
38
43
K
15
15
18
20.5
L
2
2
2
2
Net Weight
1
1
1.5
2
M
58
58
76
76
LCM13K100 / LCM13K200 / LCM13K300
G I
AB C D E
H
FJ
KLM
(36)
(1)
Mounting Surface Mounting Surface
Mounting Surface
Direction of Load (Positive output) Direction of Load (Positive output)
Direction of Load (Positive output)
LCM13 SeriesBeam Type Stainless Steel Load Cell
LCM13K100
LCM13K200
LCM13K300
LCM13K500
LCM13T001
LCM13T002
LCM13T003
LCM13T005
102kgf(1kN)
204kgf(2kN)
306kgf(3kN)
510kgf(5kN)
1tf(10kN)
2tf(20kN)
3tf(30kN)
5tf(50kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.1%
150% of R.C.
0.03% of R.O.
DC5 to 12V
DC15V
±1% of R.O.
380±20Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 40ºC
0.016% of R.O./10ºC
0.013% of Load/10ºC Typ.
ø4/3m
IP67
Model No. Capacity
LCM13K100
LCM13K200
LCM13K300
LCM13K300
LCM13T001
LCM13T002
LCM13T003
LCM13T005
M12
M12
M12
M12
M12
M20
M20
M20
Bolt diameter
80Nm
80Nm
80Nm
80Nm
80Nm
400Nm
400Nm
400Nm
Clamping torque
Applicable clamping torque
Weighing Module Kit* See P25 for more details
Swivel Foot for LCM13
13
Beam Type
Model No.LC4221K010/020/050 LC4221K100/200/300
A2725
B1820
C6565
D1010
Eø6.6ø8.4
Fø8.1
ø10.1
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
Net Weight : 0.8kgUnit = mm
LC-4221 SeriesHermetically Sealed, Beam Type Stainless Steel Load Cell Ideal for measurements in harsh environments
LC-4221-K010
LC-4221-K020
LC-4221-K050
LC-4221-K100
LC-4221-K200
LC-4221-K300
10kgf (98.1N)
20kgf (196N)
50kgf (490N)
100kgf (981N)
200kgf (1.96kN)
300kgf (2.94kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.2%
200% of R.C.
0.05% of R.O.
DC12V
DC15V
±1% of R.O.
Approximately 400Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 60ºC
0.07% of R.O./10ºC
0.02% of Load/10ºC Typ.
ø6/5m
IP67
Model No. Capacity
LC-4221-K010
LC-4221-K020
LC-4221-K050
LC-4221-K100
LC-4221-K200
LC-4221-K300
M6
M6
M6
M8
M8
M8
Bolt diameter
15Nm
15Nm
15Nm
30Nm
30Nm
30Nm
Clamping torque
Applicable clamping torque
14
Beam Type
Model No.LC5206-K300/K500LC5206-T001/T002
A137185
B*1010
C5288
D55
57.5
E30
39.5
F31
43.2
G1935
H1619
I25
44.5
J83
102.5
K10.517
L10517
M–
72.5
N–
5.5
P–
0.8
Net Weight(kg)0.71.7
Unit = mm B* : Approximately
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
LC-5206 Series
LC-5206-K300
LC-5206-K500
LC-5206-T001
LC-5206-T002
300kgf (2.94kN)
500kgf (4.90kN)
1tgf (9.81kN)
2tgf (19.6kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.2%
200% of R.C.
0.02% of R.O.
DC12V
DC15V
±1% of R.O.
Approximately 400Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 60ºC
0.07% of R.O./10ºC
0.02% of Load/10ºC Typ.
ø6/3m (K300/K500)
ø6/3m (T001/T002)
IP67
Model No. Capacity
Beam Type Tool Steel Load Cell
LC-5206-K300
LC-5206-K500
LC-5206-T001
LC-5206-T002
M10
M10
M16
M16
Bolt diameter
60Nm
60Nm
250Nm
250Nm
Clamping torque
Applicable clamping torque
15
Beam Type
Model No. A
130
171
B
16
19
C
25
38
D
76
95
E
13
19
F
32
38
H
52
76
J
ø14
ø21
K
M12P=1.75
Depth16
M20P=1.5
Depth19
L
26
38
1
1.5
Net Weight(kg)LC5223-K500LC5223-T001LC5223-T1.5LC5223-T002LC5223-T003LC5223-T005
Unit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
Spacer
LC-5223 SeriesBeam Type Tool Steel Load Cell
LC-5223-K500
LC-5223-T001
LC-5223-T1.5
LC-5223-T002
LC-5223-T003
LC-5223-T005
500kgf(4.90kN)
1tf (9.81kN)
1.5tf (14.7kN)
2tf (19.6kN)
3tf (29.4kN)
5tf (48.0kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.2%
150% of R.C.
0.03% of R.O.
DC12V
DC15V
±1% of R.O.
Approximately 400Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 60ºC
0.07% of R.O./10ºC
0.02% of Load/10ºC Typ.
ø4/3m
IP67
Model No. Capacity
LC-5223-K500
LC-5223-T001
LC-5223-T1.5
LC-5223-T002
LC-5223-T003
LC-5223-T005
M12
M12
M12
M12
M20
M20
Bolt diameter
80Nm
80Nm
80Nm
80Nm
400Nm
400Nm
Clamping torque
Applicable clamping torque
16
Load cell bracket (stationary side)
Load cell bracket (load side)
Load cell
Rod-end bearing
Joint
Protective hardware
Tension TypeTension type load cells are ideal for tensile measurements (compression measurements are also possible).Installation is easy (safety precautions must be observed). The structure is less susceptible to biased loading.
Example ApplicationslHopper scales
lTension measurement, etc.
Example of InstallationUsing LC-1205
17
Tension Type
Model No.LC1205-K020/K050LC1205-K100
A5050
B6464
C1912
D2316
Net Weight(kg)0.30.4
M5P5DepthM651511M651510
LC1205-K200/K500LC1205-T001A
5075
64100
1924
2328
0.51.3
M1251.75510M1851.5525
LC1205-T002LC1205-T005
7575
100100
2436
2840
1.31.9
M1851.5522.5M2452521
Unit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
(Tension)
(Compression)
LC-1205 SeriesTension type Tool Steel Load Cell
LC1205-K020
LC1205-K050
LC1205-K100
LC1205-K200
LC1205-K500
LC1205-T001A
LC1205-T002
LC1205-T005
20kgf (192N)
50kgf (490N)
100kgf (981N)
200kgf (1.96kN)
500kgf (4.90kN)
1tf (9.81kN)
2tf (19.6kN)
5tf (49.0kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.5%
1.5mV/V±0.5% (K020/K050)
200% of R.C.
0.02% of R.O.
DC12V
DC15V
±2% of R.O.
Approximately 400Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 60ºC
0.07% of R.O./10ºC
0.02% of Load/10ºC Typ.
ø6/3m
ø6/5m (T001A/T002/T005)
IP54
Model No. Capacity
18
Tension Type
Model No.LC1216-K100LC1216-K200/K500
A104104
B6262
øC7777
D5050
Net Weight(kg)1.71.8
M5P5DepthM65159
M1251.75510LC1216-T001A(LC1216-T002)
150150
8080
102102
7575
4.04.0
M1851.5513M1851.5513
LC1216-T002A/005 180 80 102 90
E4545636363
F1616272736
G1919313141
H1616202034 5.6M2452525
Unit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
(Tension)
(Compression)
LC-1216 Series
LC1216-K100
LC1216-K200
LC1216-K500
LC1216-T001A
LC1216-T002A
LC1216-T005
100kgf (981kN)
200kgf (1.96kN)
500kgf (4.90kN)
1tgf (9.81kN)
2tgf (19.6kN)
5tgf (49.0kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.5%
200% of R.C.
0.05% of R.O.
DC12V
DC15V
±2% of R.O.
Approximately 400Ω350±3.5Ω5000MΩ/DC50V
–10ºC to 60ºC
0.07% of R.O./10ºC
0.02% of Load/10ºC Typ.
ø6/3m (K300/K500)
ø6/5m (T001A/T002A/T005)
IP67
Model No. Capacity
Hermetically Sealed Tool Steel Load CellIdeal for measurements in harsh environments
19
StopperMaximum clearance : 5mmRecommended clearance : 2 to 3mm
Base plateMutual level error : within 3mmSelf level : within 1/500
Reinforce plate
Shunt wire
Slope of bottom : more than 1/100
Use steel gonduitand flexible tube forload cell cable
Compression TypeCompression type load cells are used for compression measurements.Suitable for large capacity weighing.
Example ApplicationslTruck scales
lWeigh bridges
lHopper scales
lTank scales
lCompression measurements, etc.
Example of InstallationTruck scale
20
Compression Type
8-ø12
SUS Ball
R1/4-19
100±1
100±
1
77
77
ø78
95
1216
3
Net Weight : 4kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
LCC07 SeriesHermetically Sealed Stainless Steel Load CellEquipped with the transverse load stopper
LCC07K500
LCC07T001
LCC07T002
LCC07T003
LCC07T005
500kgf(5kN)
1tf(10kN)
2tf(20kN)
3tf(30kN)
5tf(50kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.1%
150% of R.C.
0.03% of R.O.
DC12V
DC15V
±1% of R.O.
780±20Ω700±10Ω500MΩ/DC50V
–10ºC to 40ºC
0.04% of R.O./10ºC
0.014% of Load/10ºC Typ.
ø5.6/5m
IP67
Model No. Capacity
21
Compression Type19
9±1
103
3610
012
12
8412ø72
ø72ø94
28
PT-1/2
47 42
108
150±
110
0
1408-ø20
200±1
36
Ground terminal M4
Net Weight : 7.5kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
Four-conductor shielded cable
Dust cover
LCC11/N SeriesHermetically Sealed Stainless Steel Load Cell with Very Large Weighing Capacity High resistance to adverse environmental conditions and corrosion (IP68)With or without mounting kit
LCC11T010/LCC11T010N
LCC11T020/LCC11T020N
LCC11T030/LCC11T030N
10tf (100kN)
20tf (200kN)
50tf (300kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.1%
200% of R.C.
0.016% of R.O.
DC5 to 12V
DC15V
±1% of R.O.
800±80Ω2200±10Ω5000MΩ/DC50V
–20ºC to 60ºC
0.019% of R.O./10ºC
0.010% of Load/10ºC Typ.
ø8/12m
IP68 (100h at 1.5m immersion)
Model No. Capacity
LCC11/N Series 100N • m
Normal bolt
200N • m
High-tension bolt
Applicable clamping torque
22
Compression Type
Net Weight : 23kgUnit = mm
CABLE COLOR CODERED EXC +WHITE EXC –GREEN SIG + BLUE SIG – YELLOW SHIELD
8-ø18 120±0.5
120±
0.5
130±
1.8
160±
1.8
270±2.2
300±2.2
1818
PT-1/2 225±
1
127
GroundterminalM4
Four-conductor shielded cable
LCC12 Series
LCC12T010
LCC12T020
LCC12T030
10tf (100kN)
20tf (200kN)
50tf (300kN)
SpecificationsRated output
Safe load limit
Combined error
Recommended excitation voltage
Maximum excitation voltage
Zero balance
Input terminal resistance
Output terminal resistance
Insulation resistance
Compensated temperature range
Temperature effect on
Zero balance
Span
Cable diameter/length
Dustproof/waterproof
2mV/V±0.1%
150% of R.C.
0.03% of R.O.
DC5 to 12V
DC15V
±1% of R.O.
800±80Ω2200±10Ω5000MΩ/DC50V
–20ºC to 60ºC
0.019% of R.O./10ºC
0.010% of Load/10ºC Typ.
ø8/12m
IP68 (100h at 1.5m immersion)
Model No. Capacity
Hermetically Sealed Stainless Steel Weighing Module with Very Large Weighing CapacityHigh resistance to adverse environmental conditions and corrosion (IP68)Equipped with mount assembly (transverse movement control + lift-off prevention)
LCC12 Series 75kN
Max. transverse force
80kN
Max. force for lift
Mount fixture
23
Equipment
4040
166
184
200
30166
67
2-ø8
Net Weight : 1.5kg
Unit = mm
Unit = mm
65 M
AX16
5 M
AX
160140
2-ø8
3 25
ø135
30
Unit = mm
4-M6 Hex bolt with cross slot
Cable outer diameterMax ø8For indicator
Cable outer diameterMax ø8For load cell
Phillipsscrew
Stainless Steel Summing Box AD-4379SUS
Summing Box AD-4382
Junction Box AD-4380SUS
Stainless steel (SUS304), water and dust proofAccepts cables (ø5 to ø12) from up to four load cellsEquipped with a trimmer to adjust the sensitivity for each load cell
Accepts cables from two load cellsWater and dust proofEquipped with a trimmer to adjust the sensitivity for each load cell
Used for extending a load cell cable to reach a weighing indicatorStainless steel (SUS304), water and dust proofNo trimmer to adjust the sensitivity for the load cell
24
Equipment
1050
to 6
0
2820
10
ø26
ø20.6 M12
ø58
20 to
25
1020
ø58
LCM13K500LCM13T001
Intended load cells
LCM13K100LCM13K200LCM13K300LCM13K500LCM13T001
Net Weight : 0.25kg
Unit = mm
Model No.LCZAP1413LCZAP1414LCZAP1415
A97116
B168212
C100120
D7084
E1518
F136175
øG1414
H1518
2024
J2326 60
121 227 150 100 18 190 14 25 24 29 75
50K
84114
70LI
DC
HH
A
JI
K
BFL
E
4-øG
C
4-øG
Model No.
Intendedload cells
Max. transverse forceMax. force for liftMax. displacementNet Weight
LCZAP1413LCM13K100LCM13K200LCM13K300LCM13K500LCM13T001
6kN20kN
2mm(All directions)3.4kg
LCZAP1414LCM13T002LCM13T003
12kN30kN
2mm(All directions)6.0kg
LCZAP1415LCM13T005
20kN40kN
2mm(All directions)12.0kg
Unit = mmLoad cell (sold separately)
M12 Hex nut
Weighing Module Kit LCZAP1413/1414/1415
Swivel Foot for LCM13 LCZAFT01S
Weigh Module
* Net weight does not include load cell
25
Accessories
Order No.LCB-A6
LCB-A12LCB-A18LCB-18
LCB-24-2TLCB-24-5T
Intended load cellsLC1205-K020/K050/K100, LC1216-K100, LC1122-K050/K100LC1205-K200/K500, LC1216-K200/K500, LC1122-K250/K500
LC1205-T001A, LC1216-T001ALC1205-T002
LC1216-T002ALC1205-T005, LC1216-T005
RemarksM651
M1251.75M1851.5M1851.5M2452M2452
Mounting illustrationLC-1205
Mounting illustrationLC-1216
Mounting illustration
Mounting illustration
Unit = mm Unit = mm
Unit = mm Unit = mm
ダブルコンベックス使用金具シングルコンベックス使用金具適合ロードセルIntended load cells
LC1205-K020/K050/K100LC1205-K200/K500LC1205-T001A/T002LC1205-T005
Bearing plateLCBP-1LCBP-1LCBP-2LCBP-2
Mounting plateLCMP-1LCMP-2LCMP-4LCMP-5
Load buttonLCLB-1LCLB-2LCLB-4LCLB-5
BoltM6M6
M10M10
Button-hole plateLCBHP-1LCBHP-1LCBHP-2LCBHP-3
Load buttonLCLB-1LCLB-2LCLB-4LCLB-5
BoltM6M6
M10M10
Components - Single convex Components - Double convex
Model No.LC1216-K100LC1216-K200/K500LC1216-T001A(LC1216-T002)LC1216-T002ALC1216-T005
Rod-end bearingsLCB-A6
LCB-A12LCB-A18LCB-18
LCB-24-2TLCB24-5T
A160194270285320342
B178224312328376412
C183042435670
øDH76
1218182525
E7
1217
16.322
25.3
F9
1623203135
Model No.LC1205-K020/K050/K100LC1205-K200/K500LC1205-T001ALC1205-T002LC1205-T005
Rod-end bearingsLCB-A6
LCB-A12LCB-A18LCB-18
LCB-24-5T
A116152194214268
B134182236257338
C1830424370
øDH76
12181825
E7
1217
16.325.3
F9
16232035
Model No.LC1205-K020/K050/K100LC1205-K200/K500LC1205-T001A/T002LC1205-T005
A115115164167
B7777
105105
C100100130130
D16162222
E16161919
F88
1212
H7272
115118
Model No.LC1205-K020/K050/K100LC1205-K200/K500LC1205-T001A/T002LC1205-T005
A120120178190
B7777
105105
C100100130130
D16161919
E16161919
F88
1212
H7070
110116
Rod-end bearings
Mounting illustration
Compression fixtures
Single convex Double convex
Appr
oxim
atel
y
Appr
oxim
atel
y
Appr
oxim
atel
y
Appr
oxim
atel
y
Bearing plate
Load button protector
Load cell
Mounting plate
Button-hole plate
Load button
Load cell
Button-hole plate
Load button
Mounting fixtures
26
Accessories
Unit = mm Unit = mm
ダブルコンベックス使用金具シングルコンベックス使用金具適合ロードセルIntended load cells
LC1216-K100LC1216-K200/K500LC1216-T001A/(T002)LC1216-T002A/T005
Bearing plateLCBP-1LCBP-1LCBP-2LCBP-2
Mounting plateLCMP-1LCMP-2LCMP-4LCMP-5
Load buttonLCLB-1LCLB-2LCLB-4LCLB-5
BoltM6M6
M10M10
Button-hole plateLCBHP-1LCBHP-1LCBHP-2LCBHP-3
Load buttonLCLB-1LCLB-2LCLB-4LCLB-5
BoltM6M6
M10M10
Components - Single convex Components - Double convex
ダブルコンベックス使用金具シングルコンベックス使用金具適合ロードセルIntended load cells
LC1122-K050/K100LC1122-K250/K500
Bearing plateLCBP-1LCBP-1
Mounting plateLCMP-1LCMP-2
Load buttonLCLB-1LCLB-2
BoltM6M6
Button-hole plateLCBHP-1LCBHP-1
Load buttonLCLB-1LCLB-2
BoltM6M6
Components - Single convex Components - Double convex
Unit = mm Unit = mm
Model No.LC1216-K100LC1216-K200/K500LC1216-T001A/(T002)LC1216-T002A/T005
A155155214247
B7777
105105
C100100130130
D16162222
E16161919
øF88
1212
øG7777
102102
H114114165198
J62628080
Model No.LC1216-K100LC1216-K200/K500LC1216-T001A/(T002)LC1216-T002A/T005
A160160228270
B7777
105105
C100100130130
D16161919
E16161919
øF88
1212
øG7777
102102
H110110160196
J62628080
Model No.LC1122-K050/K100LC1122-K250/K500
A131131
B7777
C100100
D1616
E1616
F88
H9090
Model No.LC1122-K050/K100LC1122-K250/K500
A136136
B7777
C100100
D1616
E1616
F88
H8686
Single convex Double convex
Compression fixtures
Single convex Double convex
Compression fixtures
Mounting illustration
Mounting illustration
Mounting illustration
Mounting illustration
Bearing plate
Load button protector
Load cell
Mounting plate
Button-hole plate
Load button
Load cell
Button-hole plate
Load button
Bearing plate
Mounting plate
Load button
Button-hole plate
Load button
Load cell
Button-hole plate
Load button
O ring (attachment of LCBHP)
27
Appearance and/or specifications subject to change for improvement without notice.
] Load Cells-ADCC-01-KO1-08703
3-23-14 Higashi-lkebukuro, Toshima-ku, Tokyo 170-0013 JAPANTelephone:[81](3) 5391-6132 Fax:[81](3) 5391-6148http://www.aandd.jp
1756 Automation Parkway, San Jose, CA 95131 U.S.A.Telephone:[1](408) 263-5333 Fax:[1](408) 263-0119
32 Dew Street, Thebarton, South Australia 5031 AUSTRALIATelephone:[61](8) 8301-8100 Fax:[61](8) 8352-7409
Unit 24/26 Blacklands Way Abingdon Business Park, Abingdon, Oxon OX14 1DY United KingdomTelephone:[44](1235) 550420 Fax:[44](1235) 550485〈German Sales Office〉
Große Straße 13 b 22926 Ahrensburg, GERMANYTelephone:[49](0) 4102 459230 Fax:[49](0) 4102 459231
Manhattan Bldg. 8F, 36-2 Yoido-dong, Youngdeungpo-gu, Seoul, KOREATelephone:[82](2) 780-4101 Fax:[82](2) 782-4280
…Clearly a Better Value
Vereyskaya str.112 Kuntsevo Block, 121357,Moscow, RUSSIATelephone:[7](495) 937-33-44 Fax:[7](495) 937-55-66