Lithium Ion and VRLA BatterySafety Monitoring for Storageand ChargingJordan AllenUniversity of Idaho ECE DepartmentECE Power Lab

Page 2: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

2

OutlineOverviewControllerTemperature SensorSetupResultsConclusionFuture Work

Page 3: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

3

OverviewThe scope of this project is to provide remote access automated monitoring for the ECE Power Lab.

An IP enabled controller will be used to monitor a temperature sensor at a select location of the lab and provide notification via email and/or relay triggering when monitoring conditions are out of the desired range.

Page 4: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

4

ControllerBarix BarioNet IP Enabled

Programmable Controller◦Built-in Web Server that is completely

customizable◦2 Relay Outputs (5A @ 250VAC)◦A Dallas 1-Wire interface that can

support up to 50,1-Wire temperature sensors

◦Operating temperature:0 to 50°C / 32 to 104°F

◦Password protected

Page 5: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

5

Controller

Page 6: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

6

Controller

PIC16F877A SCHRACK PEO14005

Page 7: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

7

Controller

[3]

Page 8: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

8

Temperature SensorTamperproof SS Flat Plate 1-Wire

Temperature Sensor◦A DS18B20 digital sensor with 12-bit

resolution◦+/- 0.5°C accuracy over range of -10 to

85°C◦Measures Temperatures from -55 to

125°C (-67 to 257°F)◦A flat plate sized to fit a single gang

box

Page 9: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

9

Temperature Sensor

123

Note:The 1-Wire interface pin (DQ) provides power to the device when used in parasite power mode. VDD must be grounded for operation in parasite power mode.

1 – GND2 – DQ (Data I/O 1-Wire interface pin)3 – VDD

DS18B20

[5]

[6]

Page 10: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

10

Temperature Sensor

[2]

Page 11: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

11

Setup

[4] [5]

Page 12: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

12

Setup

Page 13: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

13

ResultsChallenges

◦IP configuration◦SMTP setup ◦Email delay (1min. 50sec.)◦ Interpreting settings

Page 14: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

14

ResultsSuccess

◦Confirmed proper operation of relay triggering when temperature is out of set range

◦Confirmed proper operation of email notification when temperature is out of set range

Page 15: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

15

ConclusionThe BarioNet 100 has provided remote access automated temperature monitoring for the ECE Power Lab via email and/or relay triggering when monitoring conditions are out of the desired range.

Page 16: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

16

Future WorkExpand monitoring to include:

◦Two temperature sensors◦One hydrogen sensor◦One air quality sensor◦Two vibration sensors

Page 17: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

17

Acknowledgements

University of IdahoECE Department Power LabDr. Brian K. JohnsonStacey L. Page

Page 18: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

18

Questions

Page 19: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

19

References1. AG, BARIX. “BARIX ONSITE: Barionet 100 Product

Sheet V3.0.” 2009. 25 April 2011 <http://www.barix.com/downloads/Barionet_Family/51/>.

2. AG, BARIX. “BARIX ONSITE: Barionet Family Product Manual V01.18.” 2009. 25 April 2011 <http://www.barix.com/downloads/Barionet_Family/51/>.

3. AG, BARIX. “BARIX ONSITE: Barionet Quick Install Guide V1.0.” 2009. 25 April 2011 <http://www.barix.com/downloads/Barionet_Family/51/>.

4. DataNab. “Barix BarioNet IP Enabled Programmable Controller.” 25 April 2011 <http://estores.merchantpartners.com/fcwxj/product_info.php?products_id=1>.

Page 20: Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1

20

References5. DataNab. “Sensor, 1-Wire: Tamperproof SS Flat Plate

Space Temp.” 25 April 2011 <http://estores.merchantpartners.com/fcwxj/product_info.php?products_id=33>.

6. Digi-Key. “DS18B20 Programmable Resolution 1-Wire Digital Thermometer.” 2011. 25 April 2011 <http://datasheets.maxim-ic.com/en/ds/DS18B20.pdf >.