Report Number 130502119SHA-001 Original Issued: 5-Jul-2013 Revised: 4-May-2018
Standard(s)
Applicant Manufacturer
Address Address
Country CountryContact ContactPhone PhoneFAX FAXEmail Email
P.R.China
Zhenxi Village, Langxia Street, Yuyao, Ningbo
86-574-62288062
Zhenxi Village, Langxia Street, Yuyao, Ningbo
Mr. Jiang Binhua
86-574-62263280
P.R.China
86-574-62288062
1.0 Reference and Address
Ningbo Golden Age Electric Co., Ltd.
Household Electric Skillets And Frying-Type Appliances [UL 1083:2009 Ed.6+R:15Jul2016]
Ningbo Golden Age Electric Co., Ltd.
Mr. Jiang Binhua
Page 1 of 25
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 2 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Product
Brand name
Models
Model Similarity
Ratings
Other Ratings
2.0 Product Description
Grill
NA
NA
None
120V~, 60Hz, 1400W
DescriptionThe product covered by this report is household, indoor use, cord connected grill. It incorporates thermostat and thermal cut off to safeguard.
GH-815
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 3 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Photo 1 - Over view
Photo 2 - Over view
3.0 Product Photographs
1
2
3
4
5
6
7
8
9
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 4 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
3.0 Product Photographs
Photo 3 - Heating plate view
Photo 4 - Bottom view
10
11
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 5 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
3.0 Product Photographs
Photo 5 - Terminal box view
Photo 6 - Internal of top side view
12
13
14
15
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 6 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
3.0 Product Photographs
Photo 7 - Internal of top side view
Photo 8 - Internal of bottom side view
19
16
17
18
20
21
22
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 7 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Photo #
Item
no.1 NameManufacturer/
trademark2 Type / model2Technical data and securement means
Mark(s) of conformity
3
1 1Plastic handle support
SHAXIAN HONGSHENG PLASTIC CO LTD (E206745)
HG-6062J
PF, Rated V-0, HWI=0, HAI=1, RTI(150,150,150), min. thickness 1.5mm, Secured on heating plate by screws.
URus
1 2 Control panel
SHAXIAN HONGSHENG PLASTIC CO LTD (E206745)
HG-6062J
PF. Rated V-0, HWI=0, HAI=1, RTI(150,150,150), min. thickness 1.5mm, Fixed to metal enclosure by screws.
URus
Ningbo Golden Age Electric Co., Ltd.
Stainless steel Minimum thickness: 0.3mm NR
Ningbo Golden Age Electric Co., Ltd.
Iron Minimum thickness: 0.4mm NR
1 4 Plug Various VariousNEMA 1-15P, rated:125V, 15A, connected with 16AWG flexible cord.
UL or ETL
1 5 Power cord Various HPN16AWGx2C, 105°C, 0.6-2.1m length.
UL or ETL
2 6 KnobE I DUPONT DE NEMOURS & CO INC (E41938)
70G13HS1L
PA66, Rated HB, HWI=4, HAI=0, RTI(140,125,140), min. thickness 1.5mm, all color, snapped to thermostat shaft.
URus
SABIC JAPAN L L C (E207780)
2200
PEI, Rated V-0, HWI=2, HAI=3, RTI(170,170,170), min. thickness 0.8mm, all color, Snap-in the top enclosure.
URus
BAYERMATERIALSCIENCE AG (E41613)
2858
PC, Rated V-2, HWI=3, HAI=0, RTI(125,115,125), min. thickness 0.8mm, all color, Snap-in the top enclosure.
URus
2 8 Handle Ningbo Golden Age Electric Co., Ltd.
ADC12 AL, Minimum thickness: 0.7mm NR
2 9 Lock buttonCHI MEICORPORATION (E56070)
PA-706
ABS, Rated HB, HWI=4, HAI=0, RTI(60,60,60), min. thickness 0.6mm, all color, fixed toghter by screws.
URus
3 10 Heating plateNingbo Golden Age Electric Co., Ltd.
ADC12AL, Minimum thickness: 0.8mm, painted with PTFE, fixed to the enclosure by screws.
NR
4 11 Bottom enclosure
SHAXIAN HONGSHENG PLASTIC CO LTD (E206745)
HG-6062J
PF, Rated V-0, HWI=0, HAI=1, RTI(150,150,150), min. thickness 1.5mm, Fixed to heating plate by screws.
URus
5 12Terminal box cover
SAMSUNGTOTALPETROCHEMICALS CO LTD (E140331)
FB51
PP, Rated V-2, HWI=2, HAI=0, RTI(130,130,130), min. thickness 1.5mm, all color, Fixed to bottom enclosure by screws.
URus
4.0 Critical Components
Indicator cover72
Metal enclosure31
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 8 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Photo #
Item
no.1 NameManufacturer/
trademark2 Type / model2Technical data and securement means
Mark(s) of conformity
3
4.0 Critical Components
5 13 Wire connectorHEAVY POWERCO LTD (E113650)
CE2 300V, 150°C. URus
6 14 Indicator support
SHANDONG JINBAO ELECTRONICS CO LTD (E141940)
ZD-95(G)F1V-0, 130°C, secured on control panel by screw.
URus
6 15Sleeving of internal wire
SHENZHENWAHCHANGWEIINDUSTRIAL COLTD (E233803)
SRS-70Grade A silicone-polymer coatedfiberglass sleeving, 600V, 200°C.Used to cover internal wire.
URus
CIXI SHUANGHONG WIRE CO LTD (E333296)
3122300Vac, 200ºC, 22AWG used for lamp, 18-20AWG for other use, passed VW-1 per UL 1581.
See 5.0
Various 3122300Vac, 200ºC, VW-1, 22AWG used for lamp, 18-20AWG for other use.
URus
SHAOXING XINDA ELECTRONICS CO LTD (E329518)
KST820
AC 125V, 15A, 50000 cycles, T250, The operating temperature is 190ºC, secured to cooking plate by one screw.
URus
ZHEJIANG SKYWELL ELECTRICAL APPLIANCE CO LTD (E249977)
S-A
AC 125V, 16A, 50000 cycles, T250, The operating temperature is 190ºC, secured to cooking plate by one screw.
URus
SHAOXING ZHONGXIN ELECTRIC APPLIANCES CO LTD (E243487)
KST220
AC 125V, 15A, 30000 cycles, T250, The operating temperature is 190ºC, secured to cooking plate by one screw.
URus
HAIYAN DONGHAI ELECTRICAL APPLIANCE CO LTD (E481296)
TYP96A
AC 125V, 15A, 100000 cycles, T250, The operating temperature is 190ºC, secured to cooking plate by one screw.
URus
7 18 Mica
ZHEJIANG RONGTAI ELECTRIC MATERIAL CO LTD (E231452)
R-5660-X94V-0, Min.thickness 0.35mm. Secured on heating plate by screw and metal plate.
URus
Internal wire
Thermostat 177
167
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 9 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Photo #
Item
no.1 NameManufacturer/
trademark2 Type / model2Technical data and securement means
Mark(s) of conformity
3
4.0 Critical Components
SIN TIONG WAH ELECTRIC PRODUCTS (SHENZHEN) CO LTD (E146955)
FSG-3A*#Grade A silicone-polymer coated fiberglass sleeving, 600V, 200°C.
URus
SHENZHEN WAHCHANGWEI INDUSTRIAL CO LTD (E233803)
SRS-70Grade A silicone-polymer coated fiberglass sleeving, 600V, 200°C.
URus
NINGBO HOPE WELL INSULATION MATERIAL CO (E238349)
SRG-504Grade A silicone-polymer coated fiberglass sleeving, 600V, 200°C.
URus
AUPO ELECTRONICS LTD (E140847)
BF240+Rated: AC120V, 15A, Tf240°C. Covered by insulation sleeving and secured by a depressor
URus
ZHONGSHAN SHENG PING THERMAL PROTECTORS CO LTD (E225340)
SPF240Rated: AC120V, 15A, Tf240°C. Covered by insulation sleeving and secured by a depressor
URus
NEC SCHOTT COMPONENTS CORP (E71747)
SF240ERated: AC120V, 15A, Tf240°C. Covered by insulation sleeving and secured by a depressor
URus
8 21 Heating elementNingbo Golden Age Electric Co., Ltd.
KTG-11AC 120V, 60Hz, 700W, pressured in the groove of the cooking plate.
See 5.0
8 22 Quick connector
ZHEJIANGYUESHENELECTRON COLTD (E315941)
TJC3-XXYSeries
Used for internal wire to heating element and thermostat. Min. thickness 0.3mm.
URus
HANGZHOU HENGBO LABEL CO LTD (MH26685)
JH-1Max. temp. 80°C, min. temp. –40°C, Adhere to surface of the bottom enclosure.
URus
3M CHINA CO LTD (MH45276)
57830Max. temp.80°C, min. temp. –30°C, Adhere to surface of the bottom enclosure.
URus
8 19Insulation of thermal cut off
NOTES:1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used.3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.
4 23Marking plate (not show)
8 20 Thermal cut off
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 10 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Photo # Item no.
8 21
-
Frequency: Annual 3
Dimension checking As below drawing
Dielectric StrengthApply voltage Between Test Voltage Test TimeLive parts and sheath 1000V
VERIFICATION PROCESS
Live parts and housing
See resistance per element above.
1200V 1 second
Test Name Test ParametersWinding resistance
Test Site: CEC Number of samples to test:
1 minute
Manufacturer/Trademark Type / model
Dimensions/thickness/assembly information
Insulation class
MATERIALS LIST (refer to the picture below for assembly drawing) Component Manufacturer Type/modelCore material
Ningbo Golden Age Electric Co., Ltd.
0Cr25AL5 20.6ΩInsulator MgO thickness: over 1.4mm
Encasement Silicone rubber thickness: over 1.2mm
5.0 Critical Unlisted CEC Components
Component Standard used: UL 1030, Seventh Edition, Rev. Feb. 2, 2010
Heating elementNingbo Golden Age Electric Co., Ltd.
KTG-11
Electrical Rating: 120V, 60Hz, 700W
HEATER ELEMENT Name
Sheath Stainless steel Ø6.6mm, thickness: 0.7mm
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 11 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
5.0 Critical Unlisted CEC Components
Photo # Item no.
7 16
NA
Frequency: Annual 1
MATERIALS LIST
LEAD WIREName Manufacturer/Trademark Type / model
Internal wireCIXI SHUANGHONG WIRE CO LTD (E333296)
3122
Electrical Rating:300Vac, 200ºC, 22AWG used for lamp, 18-20AWG for other use
Insulation class
Component Standard used: UL 1581, refer to VW-1 test report by INTERTEK 140301364SHA-001
VERIFICATION PROCESS
CEC
Component Manufacturer Type/model Length
Lead wireCIXI SHUANGHONG WIRE CO LTD
3122 1.2M for test
Continues to flame time 30 secondsCotton Not be ignited
Number of samples to test:
Test Name Test result Indicator flag Not be ignited
Test Site:
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 12 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component.
3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.
4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a plastic enclosure constructed with no openings other than those specifically described in Sections 4 and 5.
5. Grounding - NA.6. Polarized Connection - This product is provided with a polarized power supply connection. All single pole
switches and thermal cut-out are connected only to the ungrounded supply circuit conductor..7. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating
in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets. All wiring is minimum 22 AWG, with a minimum rating of 300V, 200°C.
8. Schematics - None9. Markings - The product is marked on as labeling system as described in item no. 23 of Section 4.0 and refer
to Illustration 1 for details: manufacturer's name, model number, date of manufacturer, electrical ratings, warning sentences etc.
10. Cautionary Markings - Refer to Illustration No. 1 for details.11. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are
provided by the manufacturer. Refer to Illustration No(s). 2 for details.
Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.
6.0 Critical Features
Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.
1. Spacing - In primary circuits, 1.6 mm minimum for USA is maintained through air and over surfaces of insulating material between current-carrying parts of opposite polarity and 1.6 mm minimum between such current-carrying parts and dead-metal parts or low voltage isolated circuits.
Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.
Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard.Construction Details - For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 13 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Illustration 1 - Marking label
Remark:
7.0 Illustrations
Remark:
1. The precautionary signal word such as “WARNING” shall be in letters not less than 2.4 mm high, if contrasting
color is used, lettering other than signal words can be a minimum of 1.6 mm high.
2. The control number and wording “CONFORMS TO UL STD.1083” and similar shall be at least 1.5 mm high.
3. Note: MM for month, YY for year.
4. Carton marking: "Household use only"5. The ETL logo shall be legible and clear.
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 14 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
7.0 IllustrationsIllustration 2 - Manual instruction
Remark: 1. "IMPORTANT SAFEGUARDS" and "SAVE THESE INSTRUCTIONS" shall be in letters not less
than 4.8mm high.
2. Upper case letters shall not be less than 2.0mm hith, Lower case letters shall not be less than 1.6mm high.
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 15 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
7.0 IllustrationsIllustration 2a - Manual instruction(Continued)
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 16 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
7.0 IllustrationsIllustration 2b - Manual instruction(Continued)
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 17 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
7.0 IllustrationsIllustration 2c - Manual instruction(Continued)
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 18 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
7.0 IllustrationsIllustration 2d - Manual instruction(Continued)
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 19 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Evaluation Period Project No.130502119SHA-001
Sample Rec. Date 5/29/2013 Condition Prototype Sample ID. 0130529-02-001Test LocationTest Procedure
UL 746C, 6th Edition, Rev. Feb 6, 2013 Clause
----------
------------------315661
----
----
Evaluation Period Project No. 140400768HZH
Sample Rec. Date 4/29/2014 Condition Prototype Sample ID. 1140429-06-006Test LocationTest Procedure
Resistance to impact Test --
Dieletrical Voltage-Withstand Test 10
Power Input Test 9Leakage Current Test 12
Mold-stress relief distortion Test --
Test Description
UL 1030, 7th edition, rev. February 2, 2010
Control Devices Tests 48--Strain Relief Test After Mold Stress-Relief Distortion
37Mechanical Endurance Test 44Stability Test
Strain Relief Test
Metal Enclosure Impact Test Push-Back Relief Test
3635
Abnormal Operation Test 46
Power Input Test 26
Dielectric Voltage-Withstand test 3334
2831
Insulation Resistance and Leakage Current Tests as a Result of Moisture
8.0 Test Summary
2013-05-29 to 2013-06-29
Inetrtek Testing Services Shanghai LimitedTesting Lab
UL 1083, Sixth Edition, Dated June 17, 2011 Clause
16Test Description
32
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
Thermal cut offs
VW-1 test Section 1080
2014-04-29 to 2014-06-09
Intertek Testing Services Shanghai Ltd.Testing Lab
Refer to test report 140301364SHA-001 by INTERTEK. Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
Test Description UL 1581
Normal Temperature Test
Leakage Current Test 27Operational Tests
The following tests were performed:
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 20 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
8.0 Test SummaryEvaluation Period Project No. 140900183HZHSample Rec. Date NA Condition Prototype Sample ID. NATest LocationTest Procedure
UL 746C, 6thEdition, Rev.August 29, 2013Clause
Evaluation Period Project No. 180401099SHASample Rec. Date NA Condition Prototype Sample ID. NATest LocationTest Procedure
-
Completed by: Reviewed by:Title: Title:
Signature: Signature:
8.1 Signatures A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0.
Gavin Fu Wayle ChenEngineer Reviewer
Test Description
UL 1083, Sixth Edition, Dated January 9, 2009, Rev. May 29,
2014Clause
2014-09-11 to 2014-10-09
16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, ChinaTesting Lab
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
None tests need to do.
2018-04-13 to 2018-05-03
Intertek Testing Services Shanghai Ltd.Testing Lab
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
None tests need to do.
Test DescriptionUL 1083:2009 Ed.6+R:15Jul2016
Clause
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 21 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
BASIC LISTEE
Address
CountryProduct
MULTIPLE LISTEE 1AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
MULTIPLE LISTEE 2AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
MULTIPLE LISTEE 3AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
None
None
None
MULTIPLE LISTEE 1 MODELS
MULTIPLE LISTEE 3 MODELS
MULTIPLE LISTEE 2 MODELS
GrillP.R.China
9.0 Correlation Page For Multiple ListingsThe following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.
Ningbo Golden Age Electric Co., Ltd.
Zhenxi Village, Langxia Street, Yuyao, Ningbo
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 22 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
10.0 General InformationThe Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.
COMPONENTSComponents used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions.
LISTING MARKThe ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.
The mark must include the following four items:
1) applicable country identifiers "US" and/or "C" or "US", "C" and "EU" 2) the word "Listed" or "Classified" or "Recognized Component" (whichever is appropriate)3) a control number issued by Intertek 4) a product descriptor that identifies the standards used for certification. Example:
For US standards, the words, “Conforms to” shall appear with the standard number along with the word, “Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”
For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”
Can be used together when both standards are used.
Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.MANUFACTURING AND PRODUCTION TESTSManufacturing and Production Tests shall be performed as required in this Report.
FOLLOW UP SERVICEPeriodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:
1. Conformance of the manufactured product to the descriptions in this Report.2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification 3. Manufacturing changes.4. Performance of specified Manufacturing and Production Tests.
In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions:
1. Correct the non-conformance.2. Remove the ETL Mark from non-conforming product.3. Contact the issuing product safety evaluation center for instructions.
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 23 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
10.1 Evaluation of Unlisted Components
Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing when these components must be selected and sent to the CEC for re-evaluation
Ship the samples to:Intertek Testing Services Shanghai LimitedETL Component Evaluation CenterBuilding No. 86, 1198 Qinzhou Road (North)Shanghai 200233, ChinaAttn: Ms. Angela HanSample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial
component shipment.
Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 24 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Product Test Voltage Test TimeAll products covered by this Report. 1000V 60 s
or1200V 1 s
The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA.If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration.
Products Requiring Dielectric Voltage Withstand Test:
Products Requiring Polarization Test:All products covered by this Report.
11.2 Polarization Test:MethodEach appliance provided with a polarized attachment plug (2-wire plug with one blade wider than another) shallbe tested with a polarized continuity between the grounded supply-circuit conductor of the attachment plug (wideblade of a 2-wire plug) and the part of the appliance that is intended to be connected to the grounded supply-circuit conductor. If the continuity cannot be readily determined by visual inspection and component checking, anelectrical continuity test is to be made.
The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown.
Test Equipment
Method
The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.
One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test.
The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.
11.1 Dielectric Voltage Withstand Test
11.0 Manufacturing and Production TestsThe manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:
Required TestsDielectric Voltage Withstand TestPolarization Test
ED 16.3.15 (20-Apr-17) Mandatory
Report No. 130502119SHA-001Ningbo Golden Age Electric Co., Ltd.
Page 25 of 25 Issued: 5-Jul-2013Revised: 4-May-2018
Date/ Project Handler/Proj # Site ID Reviewer
10-Jun-2014Gavin Fu/Jackie Zhao
4 16
Specify one manufacturers, revise technical data and describe as unlisted components, Add an alternative "Various" including "300Vac, 200ºC, VW-1, 22AWG used for lamp, 18-20AWG for other use." technical data.
140400768HZH
4 17Add alternative thermostat type KST220 manufactured by SHAOXING ZHONGXIN ELECTRIC APPLIANCES CO LTD.
5 \ Add annual test for above lead wire8 \ Add the test information for lead wire
10-Oct-2014Gavin Fu/Jackie Zhao
1 \Updated the standard to Household Electric Skillets and Frying-Type Appliances - UL 1083, Sixth Edition, Dated January 9, 2009, Rev. May 29, 2014
140900183HZH
8 \ Added the information for changes.
8-Aug-2016Gavin Fu/Wayle Chen
4 4,5 Add the verified mark "ETL" in "Mark(s) of conformity"
160800399SHA
4 17 Add alternative thermostat type TYP96A.
4-May-2018Gavin Fu/Wayle Chen
1 \
Update standard from "Household Electric Skillets and Frying-Type Appliances - UL 1083 Issue:2009/01/09 Ed:6 Rev:2014/05/29 " to "Household Electric Skillets And Frying-Type Appliances [UL 1083:2009 Ed.6+R:15Jul2016]"
180401099SHA
41,2,6,7,9,11 to 23
Delete the UL file number in "Technical data and securement means", add them into "Manufacturer/ trademark" for items 1,2,6,7,9,11 to 23.
8 \ Add the testing information about the change.
12.0 Revision SummaryThe following changes are in compliance with the declaration of Section 8.1:
Section Item Description of Change
ED 16.3.15 (20-Apr-17) Mandatory